Tech Spec Page for Amendment 241, Revising the Technical Specifications for the Primary Containment Leakage Rate Testing Program
ML041540110
Person / Time
Site: Hatch  
Issue date: 05/28/2004
From:
NRC/NRR/DLPM/LPD2
To:
Gratton C, NRR/DLPM 415-1055
References
TAC MC1432, TAC MC1433
Download: ML041540110 (1)


Text

Programs and Manuals Programs and Manuals 5.5 5.5 Programs and Manuals (continued) 5.5.12 Primary Containment Leakage Rate Testing Program A program shall be established to implement the leakage rate testing of the primary containment as required by 10 CFR 50.54(o) and 1 0 CFR 50, Appendix J, Option B, as modified by approved exemptions. This program shall be in accordance with the guidelines contained In Regulatory Guide 1.1 63, "Performance-Based Containment Leak-Test Program,* dated September 1995, as modified by the following exception to NEI 94-01, Rev. 0, Industry Guideline for Implementing Performance-Based Option of 10 CFR 50, Appendix JX:

Section 9.2.3: The first Type A test after the April 1993 Type A test shall be performed no later than April 2008.

The peak calculated primary containment Internal pressure for the design basis loss of coolant accident, Pa, Is 50.8 psig.

The maximum allowable primary containment leakage rate, La, at P. Is 1.2% of primary containment air weight per day.

Leakage rate acceptance criteria are:

a.

Primary containment overall leakage rate acceptance criterion Is 5 1.0 La.

During the first unit startup following testing in accordance with this program, the leakage rate acceptance criteria are s 0.60 L for the combined Type B and Type C tests, and s 0.75 L for Type A tests;

b.

Air lock testing acceptance criteria are:

1)

Overall air lock leakage rate Is 5 0.05 L when tested at Z Pat

2)

For each door, leakage rate Is 5 0.01 La when the gap between the door seals Is pressurized to 2 10 psig for at least 15 minutes.

The provisions of SR 3.0.2 do not apply to the test frequencies specified In the Primary Containment Leakage Rate Testing Program.

(continued)

HATCH UNIT 1 5.0-1 6 Amendment No.

241