AmerenUE Callaway Plant PO Box 620 Fulton, MIO 65251 May 21, 2004 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop PI-137 Washington, DC 20555-0001 ULNRC-5004 WAmeren UE Ladies and Gentlemen:

DOCKET NUMBER 50-483 CALLAWVAY PLANT UNIT I UNION ELECTRIC CO.

FACILITY OPERATING LICENSE NPF-30 1999 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT Enclosed are revised sections of the 1999 Annual Radioactive Effluent Release Report (ARERR). This submittal includes revised Meteorological data tables and recalculated doses to the public from gaseous releases in 1999. These tables were revised due to intermittent electrical interferences that affected the Primary Meteorological Tower 10 and 60 meter wind speed transmitters. These errors resulted in a slight increase in the calculated dose to the public. However, the calculated dose is still only a small percentage of the regulatory limits.

Sincerely, Keith D. Young Manager, Regulatory Affairs DJW/hao Enclosure a subsidiary olAmeren Corporation

ULNRC-5004 5/21/04 Page 2 cc:

U.S. Nuclear Regulatory Commission (Original and I copy)

Attn: Document Control Desk Mail Stop P1-137 Washington, DC 20555-0001 Mr. Bruce S. Mallett Regional Administrator U.S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-4005 Senior Resident Inspector Callaway Resident Office U.S. Nuclear Regulatory Commission 8201 NRC Road Steedman, MO 65077 Mr. Jack N. Donohew (2 copies)

Licensing Project Manager, Callaway Plant Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Mail Stop 7EI Washington, DC 20555-2738 Missouri Public Service Commission Governor Office Building 200 Madison Street PO Box 360 Jefferson City, MO 65102-0360

TABLE 5 DOSE AT THE SITE BOUNDARY AND TO THE NEAREST RESIDENT FROM GASEOUS EFFLUENTS SITE BOUNDARY NEAREST RESIDENT LOCATION: 2.20 km NNW LOCATION: 2.90 km NNWV AGE GROUP: CHILD AGE GROUP: CHILD ORGAN UNITS DOSE

% LIMIT(a)

DOSE

% LIMIT(b)

1. GAMMA AIR DOSE
  • MRAD 1.27E-03 0.01 8.40E-04 N/A
2. BETA AIR DOSE
  • MRAD 1.60E-03 0.01 1.06E-03 NIA
3. WHOLE BODY ***

MREM 2.32E-03 N/A 1.511E-03 N/A

4. SKIN ***

MREM 3.32E-03 N/A 2.17E-03 N/A

5. BONE **

MREM 1.16E-03 N/A 5.33E-03 0.04

6. LIVER **

MREM 3.40E-03 N/A 1.87E-02 0.12

7. TOTAL BODY **

MREM 3.39E-03 N/A 1.46E-02 0.10

8. THYROID **

MREM 3.40E-03 N/A 1.53E-02 0.10

9. KIDNEY **

MREM 3.39E-03 N/A 1.54E-02 0.10

10. LUNG **

MREM 3.43E-03 N/A 1.44E-02 0.10

11. GI-LLI **

MREM 3.39E-03 N/A 1.39E-02 0.09

  • Dose from Noble Gases only
    • Dose from Tritium, Radioiodines, and Particulates only
      • Dose from Noble Gases plus Ground Plane dose (a) Annual dose limits of Offsite Dose Calculation Manual (APA-ZZ-01003) of 10 mrad gamma air dose and 20 mrad beta air dose.

(b) Annual dose limits of Offsite Dose Calculation Manual (APA-ZZ-01003) of 15 mrem to any organ from I-131, 1-133, H-3 and particulate radionuclides with halflives greater than 8 days.

Page I of 1

TABLE 6 DOSE TO THE MEMBER OF THE PUBLIC FROM ACTIVITIES WITHIN THE SITE BOUNDARY EFFLUENT DIRECT DIRECT TOTAL DOSE WITHIN RADIATION RADIATION DOSE THE SITE FROM THE FROM OUTSIDI FOR THE ORGAN UNITS BOUNDARY UNIT TANKS YEAR

1. SKIN MREM 6.60E-04 N/A N/A 6.60E-04
2. BONE MREM 3.4 lE-04 8.79E-03 1.30E-03 1.04E-02
3. LIVER MREM 1.17E-03 8.79E-03 1.30E-03 1.13E-02
4. TOTAL BODY MREM 1.53E-03 8.79E-03 1.30E-03 1.16E-02
5. THYROID MREM 1.17E-03 8.79E-03 1.30E-03 1.13E-02
6. KIDNEY MREM 1.17E-03 8.79E-03 1.30E-03 L

.13E-02

7. LUNG MREM 1.18E-03 8.79E-03 1.30E-03 1.13E-02
8. GI-LLI MREM 1.17E-03 8.79E-03 1.30E-03 1.13E-02 Page 1 of I

TABLE 7 TOTAL DOSE DUE TO THE URANIUM FUEL CYCLE (MEMBER OF THE PUBLIC)

ORGAN UNITS DOSE FROM DOSE AT THE ACTIVITIES RESIDENCE WITHIN SITE LOCATION BOUNDARY TOTAL DOSE TO THE MEMBER OF THE PUBLIC

1. SKIN MREM 4.98E-04 6.60E-04 1.16E-03 0.00
2. BONE MREM 6.72E-04 1.04E-02 1.1 E-02 0.04
3. LIVER MREM 3.58E-03 1.13E-02 1.48E-02 0.06
4. TOTAL BODY MREM 3.66E-03 1.16E-02 1.53E-02 0.06
5. THYROID MREM 3.14E-03 1.13E-02 1.44E-02 0.02
6. KIDNEY MREM 3.16E-03 L.13E-02 1.44E-02 0.06
7. LUNG MREM 3.03E-03 1.13E-02 1.43E-02 0.06
8. GI-LLI MREM 3.01E-03 1.13E-02 1.43E-02 0.06
  • Annual dose limits from 40CFR190.10(a) of 25 mrem whole body, 75 mrem to the thyroid, and 25 mrem to any other organ.

Page 1 of 1

Union Electric - Callaway Plant Report Date/Time: 12-MAY-2004 13:12:32.63 Meteorological Data Averages Using Hourly Averaged Data 1-JAN-199900:00:00.00 to 31-DEC-1999 23:00:00.00

% GOOD DATA UNITS VALUES Stability Class A-G E

97%

Total Precipitation CM.

1.02E+02 98%

10 Meter Level:

Wind Speed Meter/Sec 3.45E+00 99%

Wind Direction Degrees 1.87E+02 96%

Wind Direction Variability Degrees 1.24E+01 94%

Reference Temperature Degrees C 1.35E+01 96%

Dewpoint Degrees C 5.44E+00 94%

60 Meter Level:

Wind Speed Meter/Sec 5.46E+00 98%

Wind Direction Degrees 1.95E+02 96%

Wind Direction Variability Degrees 8.07E+00 98%

Dewpoint Degrees C NONE 0%

Temperature Difference 60 - 10 Degrees C 1.87E-01 97%

Page 1 of 1

Union Electric - Callaway Plant Report Date/Time: 12-MAY-2004 13:12:34.25 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1999 00:00:00.00 to 31-DEC-1999 23:00:00.00 Stability Class: A Wind Speed at 10.00 Meter Level (MPH) 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

1 11 2

3 0

0 17 NNE 1

16 1

1 0

0 19 NE 2

10 3

0 0

0 15 ENE 0

11 3

0 0

0 14 E

0 9

3 0

0 0

12 ESE 0

16 6

0 0

0 22 SE 5

55 39 7

0 0

106 SSE 7

62 35 14 0

0 118 S

5 57 48 12 1

0 123 SSW 2

79 71 9

0 0

161 SW 1

46 40 3

0 0

90 WSW 1

11 9

1 1

0 23 W

1 13 20 4

0 0

38 WNW 0

12 20 12 0

0 44 NW 4

6 21 11 0

0 42 NNW 1

5 6

1 0

0 13 TOT 31 419 327 78 2

0 857 Hours of Calm Data:

Hours of Invalid Data:

1 11 Page 1 of 7

Union Electric - Callaway Plant Report Date/Time: 12-MAY-2004 13:12:34.25 Meteorological Data Totals of Hours at Each Wind Speed & Direction I-JAN-1999 00:00:00.00 to 31-DEC-1999 23:00:00.00 Stability Class: B Wind Speed at 10.00 Meter Level (MPH)

T 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

1 9

11 5

0 0

26 NNE 0

9 5

0 0

0 14 NE 1

11 7

0 0

0 19 ENE 0

10 7

0 0

0 17 E

0 4

4 0

0 0

8 ESE 0

7 3

0 0

0 10 SE 1

18 11 7

0 0

37 SSE 1

12 9

3 0

0 25 S

2 11 10 11 1

0 35 SSW 0

7 8

3 0

0 18 SW 4

14 9

1 0

0 28 WSW 2

7 1

3 1

0 14 W

1 14 7

3 1

0 26 WNW 1

7 11 5

0 0

24 NW 0

9 12 5

0 0

26 NNW 1

15 23 2

0 0

41 TOT 15 164 138 48 3

0 368 Hours of Calm Data:

Hours of Invalid Data:

0 14 Page 2 of 7

Union Electric - Callaway Plant Report Date/Time: 12-MAY-2004 13:12:34.25 Meteorological Data.

Totals of Hours at Each Wind Speed & Direction 1-JAN-1999 00:00:00.00 to 31-DEC-1999 23:00:00.00 Stability Class: C Wind Speed at 10.00 Meter Level (MPH)

N Y

I F

1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

1 17 15 4

0 0

37 NNE 0

12 2

0 0

0 14 NE 2

20 9

0 0

0 31 ENE 0

19 10 0

0 0

29 E

0 2

4 0

0 0

6 ESE 1

4 2

1 0

0 8

SE 4

19 19 5

0 0

47 SSE 0

9 8

3 0

0 20 S

2 11 17 11 1

0 42 SSW 1

10 6

2 0

0 19 SW 0

16 9

3 0

0 28 WSW 1

5 3

1 0

0 10 W

1 8

6 3

2 0

20 WNW 1

10 16 2

1 0

30 NW 3

9 8

2 0

0 22 NNW 0

5 15 0

0 0

20 TOT 17 176 149 37 4

0 383 Hours of Calm Data:

Hours of Invalid Data:

1 11 Page 3 of 7

Union Electric - Callaway Plant Report Date/Time: 12-MAY-2004 13:12:34.25 Meteorological Data-Totals of Hours at Each Wind Speea & Direction 1-JAN-1999 00:00:00.00 to 31-DEC-1999 23:00:00.00 Stability Class: D Wind Speed at 10.00 Meter Level (MPH) r I

r I

1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

5 60 72 19 0

0 156 NNE 8

58 18 5

0 0

89 NE 12 71 44 6

0 0

133 ENE 11 58 61 4

0 0

134 E

7 29 23 10 0

0 69 ESE 10 43 19 13 0

0 85 SE 11 49 45 14 0

0 119 SSE 12 36 55 13 2

0

.118 S

12 32 40 26 5

0 115 SSW 5

36 33 11 0

0 85 SW 6

27 25 5

0 0

63 WSW 6

21 23 9

1 0

60 W

11 24 33 58 8

0 134 WNW 13 41 71 25 4

0 154 NW 4

40 56 13 0

0 113 NNW 7

57 72 18 1

0 155 TOT 140 682 690 249 21 0

1782 Hours of Calm Data:

Hours of Invalid Data:

2 63 Page 4 of 7

Union Electric - Callaway Plant Report Date/Time: 12-MAY-2004 13:12:34.25 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1999 00:00:00.00 to 31-DEC-1999 23:00:00.00 Stability Class: E Wind Speed at 10.00 Meter Level (MPH)

F I

1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

14 89 62 6

0 0

171 NNE 14 93 33 3

0 0

143 NE 34 100 36 0

0 0

170 ENE 11 64 43 9

0 0

127 E

15 69 48 14 0

0 146 ESE 16 73 69 6

1 0

165 SE 22 127 120 12 0

0 281 SSE 12 142 131 40 0

0 325 S

19 81 94 26 5

0 225 SSW 16 61 45 10 0

0 132 SW 17 46 57 14 0

0 134 WSW 20 44 15 14 6

0 99 W

9 48 61 27 0

0 145 WNW 16 68 70 23 0

0 177 NW 20 70 86 18 0

0 194 NNW 15 107 98 20 0

0 240 TOT 270 1282 1068 242 12 0

2874 Hours of Calm Data:

Hours of Invalid Data:

8 66 Page 5 of 7

Union Electric - Callaway Plant Report Date/Time: 12-MAY-2004 13:12:34.25 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1999 00:00:00.00 to 31-DEC-1999 23:00:00.00 Stability Class: F Wind Speed at 10.00 Meter Level (MPH) 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

10 48 5

3 0

0 66 NNE 17 35 7

1 0

0 60 NE 18 28 7

0 0

0 53 ENE 17 29 14 0

0 0

60 E

17 33 11 1

0 0

62 ESE 25 55 11 0

0 0

91 SE 38 153 55 0

0 0

246 SSE 28 171 47 4

0 0

250 S

23 100 39 0

0 0

162 SSW 27 60 18 0

0 0

105 SW 20 64 29 1

0 0

114 WSW 19 14 5

0 0

0 38 W

12 13 11 1

0 0

37 WNW 9

34 8

0 0

0 51 NW 16 44 7

0 0

0 67 NNW 12 54 28 4

0 0

98 TOT 308 935 302 15 0

0 1560 Hours of Calm Data:

Hours of Invalid Data:

16 40 Page 6 of 7

Union Electric - Callaway Plant Report Date/Time: 12-MAY-2004 13:12:34.25 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1999 00:00:00.00 to 31-DEC-1999 23:00:00.00 Stability Class: G Wind Speed at 10.00 Meter Level (MPH) 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

20 13 0

0 0

0 33 NNE 12 8

0 0

0 0

20 NE 10 10 0

0 0

0 20 ENE 9

12 0

0 0

0 21 E

7 16 0

0 0

0 23 ESE 8

7 0

0 0

0 15 SE 13 29 10 0

0 0

52 SSE 23 75 18 0

0 0

116 S

18 25 3

0 0

0 46 SSW 10 15 0

0 0

0 25 SW 4

33 0

0 0

0 37 WSW 5

7 0

0 0

0 12 W

7 10 3

0 0

0 20 WNW 18 8

0 0

0 0

26 NW 8

24 1

0 0

0 33 NNW 13 17 4

0 0

0 34 TOT 185 309 39 0

0 0

533 Hours of Calm Data:

Hours of Invalid Data:

Hours of Good Data:

14 17 8399 = 95.9% of Total Hours.

Page 7 of 7

Union Electric - Callaway Plant Report Date/Time: 12-MAY-2004 13:12:35.67 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1999 00:00:00.00 to 31-DEC-1999 23:00:00.00 Stability Class: A Wind Speed at 60.00 Meter Level (MPH) 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

1 6

4 1

2 0

14 NNE 0

15 4

0 1

0 20 NE 0

10 6

0 0

0 16 ENE 0

8 6

0 0

0 14 E

0 9

3 1

0 0

13 ESE 1

11 9

0 0

0 21 SE 0

35 41 16 1

0 93 SSE 1

45 47 28 2

0 123 S

1 43 46 25 6

3 124 SSW 0

36 78 35 8

0 157 SW 1

26 40 35 3

0 105 WSW 1

6 9

6 1

1 24 W

0 10 10 16 3

1 40 WNW 0

5 8

18 15 1

47 NW

.0 6

5 19 4

4 38 NNW 0

3 7

5 0

0 15 TOT 6

274 323 205 46 10 864 Hours of Calm Data:

Hours of Invalid Data:

0 5

Page 1 of 7

Uni~on Electric - Callaway Plant Report Date/Time: 12-MAY-2004 13:12:35.67 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1999 00:00:00.00 to 31-DEC-1999 23:00:00.00 Stability Class: B Wind Speed at 60.00 Meter Level (MPH) 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 5

16 6

2 0

29 NNE 0

6 8

0 0

0 14 NE 0

11 8

2 0

0 21 ENE 0

8 6

1 0

0 15 E

0 1

3 2

0 0

6 ESE 0

6 5

0 0

0 11 SE 0

14 12 9

0 0

35 SSE 1

8 12 8

2 0

31 S

0 10 8

10 8

1 37 SSW 1

2 6

7 3

0 19 SW 1

5 10 6

1 1

24 WSW 0

10 3

1 1

3 18 W

0 9

8 5

3 1

26 WNW 2

5 5

10 4

1 27 NW 0

4 8

7 4

1 24 NNW 0

9 12 14 1

0 36 TOT 5

113 130 88 29 8

373 Hours of Calm Data:

Hours of Invalid Data:

0 9

Page 2 of 7

Union Electric - Callaway Plant Report Date/Time: 12-MAY-2004 13:12:35.67 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1999 00:00:00.00 to 31-DEC-1999 23:00:00.00 Stability Class: C Wind Speed at 60.00 Meter Level (MPH)

T f

T T

I 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 4

19 5

4 0

32 NNE 1

8 8

0 0

0 17 NE 0

18 13 2

0 0

33 ENE 1

13 10 3

0 0

27 E

0 2

3 1

0 0

6 ESE 0

4 3

0 1

0 8

SE 2

12 16 9

3 0

42 SSE 1

6 7

4 2

0 20 S

0 6

14 9

9 1

39 SSW 0

7 10 8

2 0

27 SW 0

8 10 6

3 0

27 WSW 1

4 4

2 1

0 12 W

1 6

5 5

0 4

21 WNW 1

6 14 9

1 3

34 NW 0

3 5

6 2

0 16 NNW 0

5 12 3

0 0

20 TOT 8

112 153 72 28 8

381 Hours of Calm Data:

Hours of Invalid Data:

0 14 Page 3 of 7

-,Union Electric - Callaway Plant Report Date/Time: 12-MAY-2004 13:12:35.67 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1999 00:00:00.00 to 31-DEC-1999 23:00:00.00 Stability Class: D Wind Speed at 60.00 Meter Level (MPH) 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

2 26 87 32 8

0 155 NNE 7

33 46 12 2

0 100 NE 5

51 64 16 0

0 136 ENE 8

37 68 22 1

0 136 E

3 15 28 14 7

0 67 ESE 7

30 38 12 6

0 93 SE 2

29 34 32 5

0 102 SSE 5

17 49 34 6

2 113 S

2 16 45 33 19 5

120 SSW 2

23 26 28 16 1

96 SW 5

16 22 24 6

0 73 WSW 1

15 17 14 9

3 59 W

6 18 24 29 34 36 147 WNW 1

23 34 66 23 8

155 NW 1

19 44 37 10 4

115 NNW 4

30 54 35 16 2

141 TOT 61 398 680 440 168 61 1808 Hours of Calm Data:

Hours of Invalid Data:

0 39 Page 4 of 7

Union Electric - Callaway Plant Report Date/Time: 12-MAY-2004 13:12:35.67 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1999 00:00:00.00 to 31-DEC-1999 23:00:00.00 Stability Class: E Wind Speed at 60.00 Meter Level (MPH) 1

.7

  • 1*

I 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

1 11 107 54 5

0 178 NNE 1

25 107 33 1

0 167 NE 3

40 113 17 1

0 174 ENE 5

16 82 33 9

0 145 E

4 11 67 50 13 0

145 ESE 0

15 88 86 1

1 191 SE 0

24 88 126 9

2 249 SSE 2

25 104 129 30 0

290 S

1 15 66 139 27 9

257 SSW 2

16 39 65 11 0

133 SW 5

16 41 70 21 2

155 WSW 2

6 34 27 16 13 98 W

3 13 36 65 30 12 159 WNW 3

9 48 85 22 10 177 NW 0

14 54 101 20 3

192 NNW 4

16 81 71 15 0

187 TOT 36 272 1155 1151 231 52 2897

,Hours of Calm Data:

Hours of Invalid Data:

0 51 Page 5 of 7

,; gUnion Electric - Callaway Plant Report Date/Time: 12-MAY-2004 13:12:35.67 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1999 00:00:00.00 to 31-DEC-1999 23:00:00.00 Stability Class: F Wind Speed at 60.00 Meter Level (MPH) 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 4

36 26 3

0 69 NNE 0

9 33 25 2

0 69 NE 0

15 43 9

0 0

67 ENE 1

10 24 16 0

0 51 E

3 12 34 31 0

0 80 ESE 0

9 53 57 2

0 121 SE 0

15 85 61 3

0 164 SSE 3

17 111 92 0

0 223 S

1 21 74 65 0

0 161 SSW 4

14 61 88 5

0 172 SW 0

7 54 62 4

0 127 WSW 0

7 29 18 2

0 56 W

0 4

12 9

1 0

26 WNW 1

3 25 22 3

0 54 NW 0

6 27 25 1

0 59 NNW 1

10 32 18 2

0 63 TOT 14 163 733 624 28 0

1562 Hours of Calm Data:

Hours of Invalid Data:

1 53 Page 6 of 7

I V~nion Electric - Callaway Plant Report Date/Time: 12-MAY-2004 13:12:35.67 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1999 00:00:00.00 to 31-DEC-1999 23:00:00.00 Stability Class: G Wind Speed at 60.00 Meter Level (MPH) 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 1

9 9

0 0

19 NNE 0

2 16 12 1

0 31 NE 1

3 26 2

0 0

32 ENE 0

2 13 8

0 0

23 E

0 5

16 4

0 0

25 ESE 0

6 15 8

0 0

29 SE 0

10 20 9

0 0

39 SSE 1

9 30 15 0

0 55 S

1 10 46 17 0

0 74 SSW 0

2 32 18 0

0 52 SW 2

2 17 20 0

0 41 WSW 1

5 14 5

0 0

25 W

1 2

6 4

0 0

13 WNW 0

7 6

10 3

0 26 NW 1

4 9

3 0

0 17 NNW 0

2 14 11 0

0 27 TOT 8

72 289 155 4

0 528 Hours of Calm Data:

Hours of Invalid Data:

Hours of Good Data:

I 35 8415 = 96.1% of Total Hours Page 7 of 7