May 27, 2004 Mr. Lew W. Myers Chief Operating Officer FirstEnergy Nuclear Operating Company Davis-Besse Nuclear Power Station 5501 North State Route 2 Oak Harbor, OH 43449-9760

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION - DAVIS-BESSE NUCLEAR POWER STATION (TAC NO. MC2185)

Dear Mr. Myers:

By letter dated February 13, 2004 (ADAMS ML040490242), you submitted a request to amend the existing exemption from Section 50.46 of the Title 10 of the Code of Federal Regulations (10 CFR), Acceptance Criteria for Emergency Core Cooling Systems for Light-Water Nuclear Power Reactors and 10 CFR 50, Appendix K, ECCS Evaluation Models, for the Davis-Besse Nuclear Power Station. The existing exemption was approved by the NRC staff by letter dated May 5, 2000 (ADAMS ML003712264).

The NRC staff has been reviewing your request and finds that it needs additional information in order to complete its review. The NRC staff developed the enclosed question and forwarded it to your staff on May 3, 2004. This question was discussed with your staff and it was agreed that you would provide a response 90 days from the date of this letter. If our understanding is not correct, please contact me at (301) 415-3027 at the earliest opportunity.

Sincerely,

/RA/

Jon B. Hopkins, Sr. Project Manager, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-346

Enclosure:

As stated cc w/encl: See next page

May 27, 2004 Mr. Lew W. Myers Chief Operating Officer FirstEnergy Nuclear Operating Company Davis-Besse Nuclear Power Station 5501 North State Route 2 Oak Harbor, OH 43449-9760

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION - DAVIS-BESSE NUCLEAR POWER STATION (TAC NO. MC2185)

Dear Mr. Myers:

By letter dated February 13, 2004 (ADAMS ML040490242), you submitted a request to amend the existing exemption from Section 50.46 of the Title 10 of the Code of Federal Regulations (10 CFR), Acceptance Criteria for Emergency Core Cooling Systems for Light-Water Nuclear Power Reactors and 10 CFR 50, Appendix K, ECCS Evaluation Models, for the Davis-Besse Nuclear Power Station. The existing exemption was approved by the NRC staff by letter dated May 5, 2000 (ADAMS ML003712264).

The NRC staff has been reviewing your request and finds that it needs additional information in order to complete its review. The NRC staff developed the enclosed question and forwarded it to your staff on May 3, 2004. This question was discussed with your staff and it was agreed that you would provide a response 90 days from the date of this letter. If our understanding is not correct, please contact me at (301) 415-3027 at the earliest opportunity.

Sincerely,

/RA/

Jon B. Hopkins, Sr. Project Manager, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-346

Enclosure:

As stated cc w/encl: See next page DISTRIBUTION:

PUBLIC AMendiola OGC FOrr PD3-2 R/F JHopkins ACRS JUhle GGrant, RIII ADAMS Accession Number: ML041420130 OFFICE PDIII-2/PM PDIII-2/LA PDIII-2/SC NAME JHopkins PCoates AMendiola DATE 05/21/04 05/21/04 05/27/04 OFFICIAL RECORD COPY

REQUEST FOR ADDITIONAL INFORMATION DAVIS-BESSE NUCLEAR POWER STATION DOCKET NO. 50-346 1.

The proposed backup boron precipitation flushing emergency core cooling system (ECCS) mode would involve ECCS flow going from the suction of the low pressure injection pumps through those pumps to the suction of the high pressure injection (HPI) pumps through a crossover line, through the HPI pumps to the pressurizer spray to the pressurizer, and finally to the reactor coolant system (RCS) hot leg through the pressurizer (J-shaped) surge line. Using spray, it takes some time to fill the pressurizer and its associated surge line sufficiently to inject into the RCS hot leg. Please provide additional information to show that this backup boron flushing path will be available when and if it is needed.

ENCLOSURE

Davis-Besse Nuclear Power Station, Unit 1 cc:

Mary E. OReilly FirstEnergy Corporation 76 South Main St.

Akron, OH 44308 Manager - Regulatory Affairs FirstEnergy Nuclear Operating Company Davis-Besse Nuclear Power Station 5501 North State - Route 2 Oak Harbor, OH 43449-9760 Director, Ohio Department of Commerce Division of Industrial Compliance Bureau of Operations & Maintenance 6606 Tussing Road P.O. Box 4009 Reynoldsburg, OH 43068-9009 Regional Administrator U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, IL 60523-4351 Michael A. Schoppman Framatome ANP 1911 N. Ft. Myer Drive Rosslyn, VA 22209 Resident Inspector U.S. Nuclear Regulatory Commission 5503 North State Route 2 Oak Harbor, OH 43449-9760 Barry Allen, Plant Manager FirstEnergy Nuclear Operating Company Davis-Besse Nuclear Power Station 5501 North State - Route 2 Oak Harbor, OH 43449-9760 Dennis Clum Radiological Assistance Section Supervisor Bureau of Radiation Protection Ohio Department of Health P.O. Box 118 Columbus, OH 43266-0118 Carol OClaire, Chief, Radiological Branch Ohio Emergency Management Agency 2855 West Dublin Granville Road Columbus, OH 43235-2206 Zack A. Clayton DERR Ohio Environmental Protection Agency P.O. Box 1049 Columbus, OH 43266-0149 State of Ohio Public Utilities Commission 180 East Broad Street Columbus, OH 43266-0573 Attorney General Office of Attorney General 30 East Broad Street Columbus, OH 43216 President, Board of County Commissioners of Ottawa County Port Clinton, OH 43252 President, Board of County Commissioners of Lucas County One Government Center, Suite 800 Toledo, OH 43604-6506 David Lochbaum, Nuclear Safety Engineer Union of Concerned Scientists 1707 H Street NW, Suite 600 Washington, DC 20006 The Honorable Dennis J. Kucinich United States House of Representatives Washington, D.C. 20515 The Honorable Dennis J. Kucinich United States House of Representatives 14400 Detroit Avenue Lakewood, OH 44107 Mr. James P. Riccio Nuclear Policy Analyst Greenpeace 702 H. Street, NW, Suite 300 Washington, DC 20001 Paul Gunter Director Nuclear Watchdog Project Nuclear Information & Resource Service 1424 16th Street NW Suite 401 Washington, DC 20009