March 31, 2004 Mr. D. M. Jamil Vice President Catawba Nuclear Station Duke Energy Corporation 4800 Concord Road York, SC 29745
SUBJECT:
CATAWBA NUCLEAR STATION, UNIT 2 RE: REQUEST FOR ADDITIONAL INFORMATION (TAC NO. MC0957)
Dear Mr. Jamil:
By letters dated April 7, 2003, and June 18, 2003, Duke Energy Corporation submitted information summarizing the End of Core 12 steam generator tube inservice inspection for Catawba Nuclear Station, Unit 2. By letter dated February 10, 2004, you submitted a response to a request for additional information from the Nuclear Regulatory Commission (NRC). The NRC technical staff has reviewed your response and has determined that additional information is required for the staff to complete its review, as identified in the Enclosure.
We discussed these issues with your staff on March 29, 2004. Your staff indicated that you would attempt to provide your response by April 30, 2004.
Please contact me at (301) 415-1842, if you have any other questions on these issues.
Sincerely,
/RA/
Sean E. Peters, Project Manager, Section 1 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-414
Enclosure:
Request for Additional Information cc w/encl: See next page
March 31, 2004 Mr. D. M. Jamil Vice President Catawba Nuclear Station Duke Energy Corporation 4800 Concord Road York, SC 29745
SUBJECT:
CATAWBA NUCLEAR STATION, UNIT 2 RE: REQUEST FOR ADDITIONAL INFORMATION (TAC NO. MC0957)
Dear Mr. Jamil:
By letters dated April 7, 2003, and June 18, 2003, Duke Energy Corporation submitted information summarizing the End of Core 12 steam generator tube inservice inspection for Catawba Nuclear Station, Unit 2. By letter dated February 10, 2004, you submitted a response to a request for additional information from the Nuclear Regulatory Commission (NRC). The NRC technical staff has reviewed your response and has determined that additional information is required for the staff to complete its review, as identified in the Enclosure.
We discussed these issues with your staff on March 29, 2004. Your staff indicated that you would attempt to provide your response by April 30, 2004.
Please contact me at (301) 415-1842, if you have any other questions on these issues.
Sincerely,
/RA/
Sean E. Peters, Project Manager, Section 1 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-414
Enclosure:
Request for Additional Information cc w/encl: See next page DISTRIBUTION:
PUBLIC RidsNrrPMSPeters PDII-1 R/F RHaag, Rgn II RidsNrrDlpmLpdii-1 (JNakoski)
JTerrell RidsOgcRp RidsRgn2MailCenter (LPlisco)
RidsAcrsAcnwMailCenter CHawes (Hard copy)
ADAMS Accession: ML040920152 NRR-106 NRR-088 OFFICE PDII-1/PM PDII-1/LA PDII-1/SC NAME SPeters CHawes JNakoski DATE 3/31/04 3/31/04 3/31/04 OFFICIAL RECORD COPY
REQUEST FOR ADDITIONAL INFORMATION DUKE POWER COMPANY CATAWBA NUCLEAR STATION, UNIT 2 DOCKET NO. 50-414 The Nuclear Regulatory Commission (NRC) staff has reviewed the licensees response dated February 10, 2004, to a request for additional information regarding the End of Core 12 steam generator tube inservice inspection for Catawba Nuclear Station, Unit 2. The NRC staff has identified the following information that is needed to enable the continuation of its review.
In your response to question 3, you indicate that you preventatively plugged two tubes (2A-1-100 and 2A-1-106) with anomalous U-bend volumetric indications. You also stated that you believe that the indications are an artifact of the plus point inspection.
A. During previous inspections, did you perform any rotating probe examinations in the U-bend area of these tubes? If so, discuss whether these anomalous indications were detected. Furthermore, if they were detected in previous inspections, discuss whether the indications changed from one inspection to the next and describe the implications of the changes.
B. If you performed rotating probe examinations in these tubes in the U-bend area during previous inspections and you did not detect anomalous indications, please provide insights on what caused the current anomalous indications.
C. Discuss your attempts to size the anomalous indications using any variety of non-destructive examination techniques so that you could confirm that the indications did not pose a structural or leakage integrity concern. Also, provide a justification for your conclusions that these indications are an artifact of the plus point inspection.
Catawba Nuclear Station cc:
Lee Keller, Manager Regulatory Compliance Duke Energy Corporation 4800 Concord Road York, South Carolina 29745 Ms. Lisa F. Vaughn Duke Energy Corporation Mail Code - PB05E 422 South Church Street P.O. Box 1244 Charlotte, North Carolina 28201-1244 Anne Cottingham, Esquire Winston and Strawn 1400 L Street, NW Washington, DC 20005 North Carolina Municipal Power Agency Number 1 1427 Meadowwood Boulevard P. O. Box 29513 Raleigh, North Carolina 27626 County Manager of York County York County Courthouse York, South Carolina 29745 Piedmont Municipal Power Agency 121 Village Drive Greer, South Carolina 29651 Ms. Karen E. Long Assistant Attorney General North Carolina Department of Justice P. O. Box 629 Raleigh, North Carolina 27602 NCEM REP Program Manager 4713 Mail Service Center Raleigh, North Carolina 27699-4713 North Carolina Electric Membership Corp.
P. O. Box 27306 Raleigh, North Carolina 27611 Senior Resident Inspector U. S. Nuclear Regulatory Commission 4830 Concord Road York, South Carolina 29745 Henry Porter, Assistant Director Division of Waste Management Bureau of Land and Waste Management Dept. of Health and Environmental Control 2600 Bull Street Columbia, South Carolina 29201-1708 Mr. R. L. Gill, Jr., Manager Nuclear Regulatory Issues and Industry Affairs Duke Energy Corporation 526 South Church Street Mail Stop EC05P Charlotte, North Carolina 28202 Saluda River Electric P. O. Box 929 Laurens, South Carolina 29360 Mr. Peter R. Harden, IV, Vice President Customer Relations and Sales Westinghouse Electric Company 6000 Fairview Road 12th Floor Charlotte, North Carolina 28210 Mary Olson Director of the Southeast Office Nuclear Information and Resource Service 729 Haywood Road, 1-A P. O. Box 7586 Asheville, North Carolina 28802
Catawba Nuclear Station cc:
Mr. T. Richard Puryear Owners Group (NCEMC)
Duke Energy Corporation 4800 Concord Road York, South Carolina 29745 Richard M. Fry, Director Division of Radiation Protection N. C. Dept. of Environment, Health, and Natural Resources 3825 Barrett Drive Raleigh, North Carolina 27609-7721