Design Features 4.0 4.0 DESIGN FEATURES 4.1 Site Location The H. B. Robinson Steam Electric
- Plant, Unit No. 2 is located on the southwest shore of Lake Robinson, in northwest Darlington
- County, South Carolina.
The site location is approximately 25 miles NW of Florence, 35 miles NNE of Sumter, and 56 miles ENE of Columbia, South Carolina.
4.2 Reactor Core 4.2.1 Fuel Assemblies The reactor shall contain 157 fuel assemblies.
Each assembly shall consist of a matrix of Zircaloy-4 fuel rods with an initial composition of natural or slightly enriched uranium dioxide (UO2) as fuel material.
Limited substitutions of zirconium alloy or stainless steel filler rods for fuel
- rods, in accordance with approved applications of fuel rod configurations, may be used.
Fuel assemblies shall be limited to those fuel designs that have been analyzed with applicable NRC staff approved codes and methods and shown by tests or analyses to comply with all fuel safety design bases.
A limited number of lead test assemblies that have not completed representative testing may be placed in nonlimiting core regions.
4.2.2 Rod Cluster Control (RCC) Assemblies The reactor core shall contain 45 full length RCC assemblies.
The control material shall be silver-indium-cadmium.
as approved by the NRC.
4.3 Fuel Storage 4.3.1 Criticality 4.3.1.1 The spent fuel storage racks are designed and shall be maintained with:
- a.
Fuel assemblies having a maximum U-235 enrichment of 5.0 weight percent:
(continued)
HBRSEP Unit No. 2 4.0-l Amendment No. 176 I_.
HBRSEP Unit No. 2 4.0-2 Amendment No. 198 Design Features 4.0 4.0 DESIGN FEATURES 4.3 Fuel Storage (continued)
- b.
keff # 0.95 in the low density storage racks if fully flooded with unborated water, which includes an allowance for uncertainties as described in Section 9.1 of the UFSAR;
- c.
keff # 0.95 in the high density storage racks if fully flooded with water borated to 1500 ppm, which includes an allowance for uncertainties as described in Section 9.1 of the UFSAR;
- d.
keff less than 1.0 in the high density storage racks if fully flooded with unborated water, which includes an allowance for uncertainties as described in Section 9.1 of the UFSAR;
- e.
A nominal 10.5 inch center-to-center distance between fuel assemblies placed in the high density fuel storage racks;
- f.
A nominal 21 inch center-to-center distance between fuel assemblies placed in low density fuel storage racks.
4.3.1.2 The new fuel storage racks are designed and shall be maintained with:
- a.
Fuel assemblies having a maximum U-235 enrichment of 5.0 weight percent;
- b.
keff # 0.95 if fully flooded with unborated water, which includes an allowance for uncertainties as described in Section 9.1 of the UFSAR;
- c.
keff # 0.98 in an optimum moderation event, which includes an allowance for uncertainties as described in Section 9.1 of the UFSAR; and
- d.
A nominal 21 inch center to center distance between fuel assemblies placed in the storage racks.
4.0 DESIGN FEATURES HBRSEP Unit No. 2 4.0-3 Amendment No. 198 Design Features 4.0 4.3.2 Drainage The spent fuel storage pool is designed and shall be maintained to prevent inadvertent draining of the pool below 18 feet above the fuel.
4.3.3 Capacity The spent fuel storage pool is designed and shall be maintained with a storage capacity limited to no more than 544 assemblies.