MONTHYEARML0231600852003-02-14014 February 2003 University of California Mcclellan Nuclear Radiation Center (Mnrc) Triga Research Reactor, Issuance of Amendment No. 5, Incorporates New Management Position & Revises TS 3.8.2 to Allow Increase in Iodine 125 Inventory Project stage: Approval ML0310705842003-11-25025 November 2003 Univ. of California, Davis, Amendment 06 to License R-130. Project stage: Other ML0334213392003-12-30030 December 2003 Regents of the Univ of California, License Amendment, Operating License No. R-130, Project stage: Other ML0407207462004-03-30030 March 2004 Revision to Safety Evaluation of Amendment No. 7 to Amended Facility Operating License No. R-130 - Regents of University of California Project stage: Approval 2003-12-30
[Table View] |
|
---|
Category:Letter
MONTHYEARML24032A1352024-02-0101 February 2024 Examination Confirmation Letter No. 50-607/OL-24-01, University of California-Davis ML23332A7062023-11-27027 November 2023 University of California, Davis Mcclellan Nuclear Research Center (MNRC) License Holder Appointment ML23263A9762023-09-22022 September 2023 Regents of the Ucd Issuance of Amendment No. 10 to Renewed Facility Operating License R-130 ML23262B5202023-09-19019 September 2023 University of California Davis Mcclellan Nuclear Research Center (Mnrc), Docket Number 50-607, License Number R-130, Supplement to License Amendment Request 2023-02 ML23258A2422023-09-15015 September 2023 University of California Davis Mcclellan Nuclear Research Center (Mnrc), Docket Number 50-607, License Number R-130, License Amendment Request 2023-02 ML23222A1872023-08-10010 August 2023 Univ. of California, Davis, 14-Day Written Follow-up to Call Made to the HOO (EM 56643) on July 28th 2023 ML23095A0652023-03-14014 March 2023 American Nuclear Insurers, Notice of Cancellation Rescinded ML23045A0452023-03-0202 March 2023 Regents of the University of California - Issuance of Amendment No. 9 to Renewed Facility Operating License No. R-130 to Amend the Technical Specifications for the University of California - Davis/Mcclellan Nuclear Research Center ML23073A3992023-03-0101 March 2023 University of California Davis Mcclellan Nuclear Research Center (MNRC) License Holder Appointment IR 05000607/20232012023-02-23023 February 2023 University of California - Davis U.S. Nuclear Regulatory Commission Routine Inspection Report 05000607/2023201 ML23045A3202023-02-14014 February 2023 14 Day Notification to Document Control Desk of Event 56331 Made to NRC Operations Center by UC Davis MNRC on February 1st at 1651 Est ML23039A2072023-02-0808 February 2023 University of California Davis Mcclellan Nuclear Research Center (Mnrc), Docket Number 50-607, License Number R-130, License Amendment Request 2023-01 IR 05000607/20222022022-12-28028 December 2022 University of California-Davis - Us Nuclear Regulatory Commission Routine Inspection Report No. 05000607/2022202 ML22214B8292022-11-21021 November 2022 Letter to Ucd with Renewed Facility Operating License ML22213A1692022-10-18018 October 2022 Regents of the University of California - Environmental Assessment and Finding of No Significant Impact Regarding Renewal of Facility Operating License No. R-130 for the University of California - Davis/Mcclellan Nuclear Research Center ML22213A1622022-10-18018 October 2022 FRN Re UCD-MNRC Environment Assessment ML22193A2532022-07-12012 July 2022 Univ. of California-Davis - Summary of the Analysis of Changes Made to the MNRC Emergency Plan Under the Provisions of 10 CFR 50.54q ML22181B0822022-06-30030 June 2022 University of California-Davis/McClellan Nuclear Research Center, Response to NRC Request for Additional Information Letter Dated June 24th, 2022 Regarding License Renewal Application ML22174A2932022-06-28028 June 2022 Regents of the University of California - Report on the Regulatory Audit License Renewal Application for the University of California - Davis/Mcclellan ML22173A2092022-06-24024 June 2022 Regents of the University of California; Request for Additional Information Regarding License Renewal Application for the University of California ML22174A4222022-06-23023 June 2022 Additional Response to NRC Request for Additional Information Letter Dated June 3rd 2022 Regarding License Renewal Application for the University of California-Davis/McClellan Nuclear Research Center ML22173A2022022-06-22022 June 2022 Response to NRC Request for Additional Information Letter Dated June 3rd 2022 Regarding License Renew Al Application for the University of California - Davis/Mcclellan Nuclear Research Center ML22172A1982022-06-21021 June 2022 UC Davis MNRC Submission of Technical Specification in Support of License Renewal Application ML22154A5442022-06-0303 June 2022 Univ. of CA - Davis, MNRC Submittal of Technical Specification in Support of License Renewal Application ML22154A5482022-06-0303 June 2022 University of California - Davis, Submittal of MNRC 2021 Annual Report ML22146A1942022-06-0303 June 2022 Regents of the University of California - RAI Regarding License Renewal Application for the University of California - Davis/Mccellan Nuclear Research Center IR 05000607/20222012022-05-26026 May 2022 University of California-Davis U.S. Nuclear Regulatory Commission Routine Inspection Report No 05000607/2022201 ML22137A2602022-05-26026 May 2022 University of California - Davis - Closure of Confirmatory Action Letter No. NRR 02 002 on the Site-Specific Compensatory Measures Implementation Plan ML23142A3032022-05-22022 May 2022 Univ. of California - Davis, Submittal of MNRC 2022 Annual Report ML22109A1042022-05-0303 May 2022 Regents of the Univ. of CA - Review of the Physical Security Plan in Support of License Renewal Application for the Univ. of CA-Davis/McCellan Nuclear Research Center ML22089A1582022-03-30030 March 2022 UC Davis MNRC Response to NRC Staff Request for Additional Information Regarding Licensing Renewal Application Letter Issued February 8th, 2022 ML22041A3782022-02-28028 February 2022 Regents of the University of California - Determination of Acceptability and Sufficiency for Docketing and Opportunity for Hearing Regarding the License Renewal Application for the University of California - Davis/Mcclellan Nuclear Research ML22038A1402022-02-0808 February 2022 Regents of the University of California - Request for Additional Information Regarding License Renewal Application for the University of California - Davis/Mcclellan Nuclear Research Center ML22026A2862022-02-0202 February 2022 Regents of the University of California - Regulatory Audit Re License Renewal Application for the University of California - Davis/Mcclellan Nuclear Research Center Training, Research, Isotope, General Atomics Nuclear Reactor ML22014A1272022-01-11011 January 2022 50 .54P Submittal of the Ucd/Mnrc Physical Security Plan for University of California, Davis Mcclellan Nuclear Research Center (Ucd/Mnrc), Docket No. 50-607, Facility Operating License No. R-130 the ML21300A3922021-12-23023 December 2021 University of California-Davis U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000607/2021202 ML21351A3172021-12-17017 December 2021 UC Davis MNRC Response to NRC Staff Request for Additional Information Regarding Licensing Renewal Application Letter Issued November 30th, 2021 IR 05000607/20212022021-12-0606 December 2021 University of California-Davis - Nuclear Regulatory Commission Security Inspection Report No. 05000607/2021202 Cover Letter ML21316A1162021-11-30030 November 2021 Regents of the University of California - Request for Additional Information Regarding License Renewal Application for the University of California-Davis Mccellan Nuclear Research Center ML21252A7572021-10-0505 October 2021 University of California-Davis/MCCLELLAN - Approval of the Revised Nuclear Radiation Center Selection and Training Plan ML21265A5412021-09-22022 September 2021 UC Davis MNRC Cover Letter for Response to Request for Supplemental Information ML21250A3662021-09-14014 September 2021 Regents of the University of California Report on the Regulatory Audit License Renewal Application for the University of California Davis/Mcclellan Nuclear Research Center Triga Nuclear Reactor ML21175A3342021-06-22022 June 2021 Transmittal of University of California, Davis, MNRC 2020 Annual Report IR 05000607/20212012021-05-0707 May 2021 University of California-Davis - U. S. Nuclear Regulatory Commission Routine Inspection Report No. 05000607/2021201 ML21029A1472021-01-25025 January 2021 UC Davis Mcclellan Nuclear Research Center - 50.54P Submittal of the Ucd/Mnrc Physical Security Plan ML20338A2622020-12-10010 December 2020 NRR-106 University of California Davis License Renewal - Regulatory Audit Letter and Plan ML20295A4242020-11-16016 November 2020 Notification of Mailing Address Change Regarding Submittal of Fingerprint Cards ML20261H3882020-09-17017 September 2020 Updated UC Davis MNRC Reactor Proposed License Renewal Ipac Trust Resources Report ML20245E5672020-09-0303 September 2020 University of California, Davis - Review of the Emergency Plan in Support of the Renewal for Facility Operating License No. R 130 IR 05000607/20202022020-08-0303 August 2020 University of California-Davis - U.S. Nuclear Regulatory Commission Routine Inspection Report 05000607/2020202 2024-02-01
[Table view] Category:Safety Evaluation
MONTHYEARML23263A9762023-09-22022 September 2023 Regents of the Ucd Issuance of Amendment No. 10 to Renewed Facility Operating License R-130 ML23045A0452023-03-0202 March 2023 Regents of the University of California - Issuance of Amendment No. 9 to Renewed Facility Operating License No. R-130 to Amend the Technical Specifications for the University of California - Davis/Mcclellan Nuclear Research Center ML0407207462004-03-30030 March 2004 Revision to Safety Evaluation of Amendment No. 7 to Amended Facility Operating License No. R-130 - Regents of University of California ML0334213392003-12-30030 December 2003 Regents of the Univ of California, License Amendment, Operating License No. R-130, ML0310705842003-11-25025 November 2003 Univ. of California, Davis, Amendment 06 to License R-130. ML0231600852003-02-14014 February 2003 University of California Mcclellan Nuclear Radiation Center (Mnrc) Triga Research Reactor, Issuance of Amendment No. 5, Incorporates New Management Position & Revises TS 3.8.2 to Allow Increase in Iodine 125 Inventory 2023-09-22
[Table view] |
Text
March 30, 2004 Dr. Barry M. Klein Vice Chancellor for Research University of California, Davis One Shields Avenue Davis, CA 95616-8558
SUBJECT:
REVISION TO SAFETY EVALUATION OF AMENDMENT NO. 7 TO AMENDED FACILITY OPERATING LICENSE NO. R-130 - REGENTS OF THE UNIVERSITY OF CALIFORNIA (TAC NO. MB5598)
Dear Dr. Klein:
The U.S. Nuclear Regulatory Commission has issued the enclosed revision to the Safety Evaluation of Amendment No. 7 to Facility Operating License No. R-130 for the McClellan Nuclear Radiation Center (MNRC) TRIGA Research Reactor. Amendment No. 7 was issued on December 30, 2003 and is available on the Commissions ADAMS system, Accession Number ML033421339.
Sincerely,
/RA/
Warren J. Eresian, Project Manager Research and Test Reactors Section New, Research and Test Reactors Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket No. 50-607
Enclosure:
Revision to Amendment No. 7 Safety Evaluation Report cc w/enclosure: Please see next page
University of California - Davis/McClellan MNRC Docket No. 50-607 cc:
Mr. Jeff Ching 5335 Price Avenue, Bldg. 258 McClellan AFB, CA 95652-2504 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
March 30, 2004 Dr. Barry M. Klein Vice Chancellor for Research University of California, Davis One Shields Avenue Davis, CA 95616-8558
SUBJECT:
REVISION TO SAFETY EVALUATION OF AMENDMENT NO. 7 TO AMENDED FACILITY OPERATING LICENSE NO. R-130 - REGENTS OF THE UNIVERSITY OF CALIFORNIA (TAC NO. MB5598)
Dear Dr. Klein:
The U.S. Nuclear Regulatory Commission has issued the enclosed revision to the Safety Evaluation of Amendment No. 7 to Facility Operating License No. R-130 for the McClellan Nuclear Radiation Center (MNRC) TRIGA Research Reactor. Amendment No. 7 was issued on December 30, 2003 and is available on the Commissions ADAMS system, Accession Number ML033421339.
Sincerely,
/RA/
Warren J. Eresian, Project Manager Research and Test Reactors Section New, Research and Test Reactors Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket No. 50-607
Enclosure:
Revision to Amendment No. 7 Safety Evaluation Report cc w/enclosure: Please see next page DISTRIBUTION:
PUBLIC RNRP\R&TR r/f SHolmes OGC MMendonca WEresian TDragoun PMadden AAdams PDoyle CBassett DMatthews EHylton PIsaac DHughes JLyons KWitt PYoung GHill (2) (T5-C3)
ADAMS ACCESSION NO: ML040720746 TEMPLATE No.: NRR-106 OFFICE RNRP:PM RNRP:LA OGC RNRP:SC NAME WEresian:rdr EHylton SUttal PMadden DATE 03/ 15 /2004 03/ 15 /2004 03/ 29 /2004 03/ 15 /2004
OFFICIAL RECORD COPY REVISION TO SAFETY EVALUATION REPORT SUPPORTING AMENDMENT NO. 7 TO AMENDED FACILITY OPERATING LICENSE NO. R-130 REGENTS OF THE UNIVERSITY OF CALIFORNIA AT McCLELLAN NUCLEAR RADIATION CENTER DOCKET NO. 50-607
1.0 INTRODUCTION
By letter dated October 21, 2003, the Regents of the University of California (the licensee) submitted a request for amendment of the Facility Operating License No. R-130 for the McClellan Nuclear Radiation Center (MNRC) TRIGA research reactor. The request provided for the allowance of radioactive materials not produced by the reactor to be received, possessed and used on the facility site. In particular, it was requested that Section 2.B of the Facility Operating License be amended to include an additional section 2.B.(4) as follows:
2.B.(4) In addition to those items specified in 2.B.(1), 2.B.(2) and 2.B.(3) the following radioactive materials may be received, possessed, and used at the facility.
Radioactive Material Chemical and/or Maximum Quantity Licensee May (element and mass number) Physical Form Possess at Any One Time A. Any radioactive material A. Any A. 20 Curies (1 Curie each, except as between atomic number 1 through provided below) 83, inclusive B. Any radioactive material with A. Any A. 4 Curies (100 millicuries each, atomic numbers 84 and above except as provided below) or up to 20 micrograms C. Iodine-125 C. Iodide/Liquid C. 40 Curies D. Source material (but only trace D. Any D. 4 grams per radionuclide, not to amounts of Th-234) exceed 10 grams total E. Special nuclear material E. Any E. 2 grams per radionuclide, not to exceed 5 grams total This amendment request was approved and issued on December 30, 2003.
2.0 EVALUATION The previous safety evaluation assumed that all of the radioactive materials to be received, possessed and handled in accordance with this amendment request would be located in the reactor room glove box. The significance of this assumption is related to the ability of the reactor room glove box and its associated exhaust system to mitigate the consequences associated with the complete volatilization of the maximum radioactive material inventory contained in the box, a total of 64.4 curies. (The total activity in categories A, B, and C in the above table is 64 curies. The maximum activity in category D is about 0.1 curie, while the maximum activity in category E is about 0.3 curie.). The staff concluded that the consequences of the complete volatilization of 64.4 curies are much less than the consequences of the bounding MHA, and the amendment request was approved.
Instead of locating all of the radioactive materials shown in above table in the reactor room glove box, some of the materials will be located in the restricted area of the McClellan Nuclear Radiation Center. Non-volatile material will be handled in accordance with approved procedures. Any unsealed volatile material, such as Iodine-125 (the majority of the radioactive materials), will continue to be handled in areas with filtered ventilation to mitigate the consequences of complete volatilization of the unsealed material (e.g., the reactor room glove box and reactor room fume hood), as previously analyzed.
The staff has reviewed the proposed change to the Facility Operating License and concluded that it does not impact the licensees ability to continue to meet the relevant requirements of 10 CFR Part 50.36.
3.0 ENVIRONMENTAL CONSIDERATION
This amendment does not involve changes in the installation or use of a facility component located within the restricted area as defined ion 10 CFR Part 20 or changes in inspection and surveillance requirements. The staff has determined that this amendment involves no significant increase in the amounts, and no significant change in the types, of any effluents that may be released off site, and no significant increase in individual or cumulative occupational radiation exposure. Accordingly, this amendment meets the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9). Pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared with the issuance of this amendment.
4.0 CONCLUSION
The staff has concluded, on the basis of the considerations discussed above, that (1) because the amendment does not involve a significant increase in the probability or consequences of accidents previously evaluated, or create the possibility of a new or different kind of accident from any accident previously evaluated, and does not involve a significant reduction in a margin of safety, the amendment does not involve a significant hazards consideration; (2) there is reasonable assurance that the health and safety of the public will not be endangered by the
proposed changes; and (3) such changes are in compliance with the Commissions regulations and the issuance of this amendment will not be inimical to the common defense and security or the health and safety of the public.
Principal Contributor: Warren J. Eresian Date: March 30, 2004