ML040710450

From kanterella
Jump to navigation Jump to search
Response to RAI on BAW-2308(NP), Revision 1, Initial RT NDT of Linde 80 Weld Materials
ML040710450
Person / Time
Site: Davis Besse, Oconee, Arkansas Nuclear, Crystal River, PROJ0693, Crane  
Issue date: 03/05/2004
From: Mallay J
B & W Owners Group, Framatome ANP Richland
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
BAW-2308(NP), Rev 1, NRC:04:011, OG:04:1840
Download: ML040710450 (2)


Text

Duke Energy Company Oconee 1, 2,3 AmerGen Energy Company, LLC TMI-1 Entergy Operations, Inc.

ANO-1 The B&W FirstEnergy Nuclear Operating Company D-B Florida Power Corporation Crystal River 3 OOwners Group Framatome ANP Working Together to Economically Provide Reliable and Safe Electrical Power March 5, 2004 NRC:04:011 OG:04:1840 Document Control Desk ATTN: Chief, Planning, Program and Management Support Branch U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Response to RAI on BAWN'-2308(NP), Revision 1, "Initial RTNDT of Linde 80 'Weld Materials."

Ref.: 1. Letter, James F. Mallay (Framatome ANP), to Document Control Desk (NRC), "B&W Owners Group Reactor Vessel Working Group Submittal of Topical Report BAW-2308, 'Initial RTNDT of Linde 80 Weld Material'," NRC:02:039, July 26,2002.

Ref.: 2. Memo, Drew Holland (NRC), to James F. Mallay (Framatome ANP), "Request for Additional Information Regarding Topical Report BAW-2308," January 6, 2004.

On behalf of the B&W Owners Group Reactor Vessel Working Group, Framatome ANP requested the NRC's review and approval for referencing in licensing actions the topical report BAW-2308(NP), Revision 1, "Initial RTNDT of Linde 80 Weld Materials" (Reference 1). In Reference 2, the NRC requested additional information to facilitate the completion of its review.

To assist in the development of the response to this RAI, and in recognition that the matter is of importance to operators of PWRs, a recognized materials specialist was sought. The EPRI Materials Reliability Program (MRP) Reactor Vessel Issues Task Group (ITG) has contracted Kim Wallin, Research Professor at VTT Industrial Systems in Finland to provide expert assistance in addressing this industry issue. This assistance is scheduled to be completed in five weeks. Consistent with the discussion held in a conference call with the NRC on February 20, 2004, a response will be provided to the RAI by June 15, 2004.

Very truly yours, James F. Mallay, Director Regulatory Affairs Framatome ANP B&W Owners Group 3315 Old Forest Road Lynchburg, VA 24501 Phone: 434-832-2981 Fax: 434-832-2475

Document Control Desk March 5, 2004 NRC:04:01 1 OG:04:1 840 Page 2 cc:

M. C. Honcharik N.

Kalyanam B&WOG Reactor Vessel Working Group Risk Informed Action Committee Project 693