..I-I CONTAINMENT SYSTEMS 3/4.6.5 VACUUM RELIEF VALVES LIMITIN CODIN FOR OPERA33ON-3.6.5 Two vacuum relief lines shall be OPERABLE.
APPLICABILITY: MODES 1, 2, 3 and 4.
ACTION:
With one vacuum relief line inoperable, restore the vacuum relief line to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
S VEILLANCE REQUIEMENTS 4.6.5 Verify each vacuum relief line OPERABLE in accordance with the Inservice Testing Program.