March 29, 2004 Mr. J. A. Scalice Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801
SUBJECT:
BROWNS FERRY NUCLEAR PLANT, UNIT 3 - APPROVAL TO USE THE 1995 EDITION THROUGH 1996 ADDENDA, SUBARTICLE IWA-2430, OF THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS BOILER AND PRESSURE VESSEL CODE FOR INSPECTION INTERVALS (TAC NO. MC2075)
Dear Mr. Scalice:
By letter dated February 20, 2004, the Tennessee Valley Authority (TVA or the licensee) requested the U.S. Nuclear Regulatory Commissions (NRCs) approval to use Subarticle IWA-2430, Inspection Intervals, in its entirety, and all related requirements of the 1995 Edition through 1996 Addenda of the American Society of Mechanical Engineers Boiler and Pressure Vessel (ASME) Code, for the remainder of the Browns Ferry Nuclear Plant (BFN), Unit 3, second 10-year inservice inspection (ISI) interval. The current ASME Code of record for BFN Unit 3 is the 1989 Edition for the second 10-year interval, which will end on November 19, 2005.
The licensee stated that Subarticle IWA-2430 of the 1995 Edition, 1996 Addenda, of the ASME Code provides greater flexibility in extending and even overlapping ISI intervals.
Title 10 of the Code of Federal Regulations (10 CFR), Section 50.55a(g)(4)(iv), states that the inservice examination of components and system pressure tests may meet the requirements set forth in subsequent editions and addenda that are incorporated by reference in 10 CFR 50.55a(b), subject to the limitations and modifications listed therein and NRC approval.
Portions of the editions or addenda may be used provided that all related requirements of the respective editions and addenda are met. TVAs request to use Subarticle IWA-2430 in its entirety, and all related requirements of the 1995 Edition, 1996 Addenda, of the ASME Code associated with ISI interval schedules is approved pursuant to 10 CFR 50.55a(g)(4)(iv) for the remainder of the current ISI interval for Unit 3.
Sincerely,
/RA/
William F. Burton, Acting Chief, Section 2 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-296 cc: See next page
ML040620465 NRR-106 OFFICE PDII-2/PM PDII-2/LA OGC EMCB/SC*
PDII-2/SC(A)
NAME KJabbour:as BClayton LC SCoffin WBurton DATE 3/23/04 3/23/04 3/29/04 3/17/04 3/29/04
FOR DISTRIBUTION: BROWNS FERRY NUCLEAR PLANT, UNIT 3 - APPROVAL TO USE THE 1995 EDITION THROUGH 1996 ADDENDA, SUBARTICLE IWA-2430, OF THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS BOILER AND PRESSURE VESSEL CODE FOR INSPECTION INTERVALS (TAC NO. MC2075)
Dated: March 29, 2004 DISTRIBUTION:
PUBLIC PDII-2 R/F BClayton (hard copy)
RidsNrrDlpmLpdii (EHackett)
RidsNrrDlpmLpdii2 (WBurton)
RidsNrrPMKJabbour RidsOgcRp RidsRgn2MailCenter (SCahill)
RidsAcrsAcnwMailCenter SCoffin GHill (2)
MMarkley SRosenberg
Tennessee Valley Authority BROWNS FERRY NUCLEAR PLANT cc:
Mr. Karl W. Singer, Senior Vice President Nuclear Operations Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. James E. Maddox, Vice President Engineering & Technical Services Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Ashok S. Bhatnagar, Site Vice President Browns Ferry Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Decatur, AL 35609 General Counsel Tennessee Valley Authority ET 11A 400 West Summit Hill Drive Knoxville, TN 37902 Mr. T. J. Niessen, Acting General Manager Nuclear Assurance Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Michael D. Skaggs Plant Manager Browns Ferry Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Decatur, AL 35609 Mr. Jon R. Rupert, Vice President Browns Ferry Unit 1 Restart Browns Ferry Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Decatur, AL 35609 Mr. Robert G. Jones Browns Ferry Unit 1 Plant Restart Manager Browns Ferry Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Decatur, AL 35609 Mr. Mark J. Burzynski, Manager Nuclear Licensing Tennessee Valley Authority 4X Blue Ridge 1101 Market Street Chattanooga, TN 37402-2801 Mr. Timothy E. Abney, Manager Licensing and Industry Affairs Browns Ferry Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Decatur, AL 35609 Senior Resident Inspector U.S. Nuclear Regulatory Commission Browns Ferry Nuclear Plant 10833 Shaw Road Athens, AL 35611 State Health Officer Alabama Dept. of Public Health RSA Tower - Administration Suite 1552 P.O. Box 303017 Montgomery, AL 36130-3017 Chairman Limestone County Commission 310 West Washington Street Athens, AL 35611