February 18, 2004 Mr. Ronald A. Jones Vice President, Oconee Site Duke Energy Corporation 7800 Rochester Highway Seneca, SC 29672

SUBJECT:

OCONEE NUCLEAR STATION, UNIT 2 - REVIEW OF FALL 2002, END-OF-CYCLE 19 STEAM GENERATOR INSPECTION REPORT (TAC NO. MC0906)

By letters dated November 12 and December 5, 2002, February 10 and February 12, 2003, you submitted reports summarizing the steam generator tube inspections performed in the Fall 2002 end-of-cycle 19 refueling outage. In addition, your staff and the Nuclear Regulatory Commission (NRC) staff participated in conference calls during the steam generator inspection activities; our summary of these conference calls was sent to you by letter dated February 25, 2003.

The NRC staff formally reviews all steam generator inspection summary reports submitted by licensees in accordance with the plants technical specification requirements. The NRC staff has reviewed your steam generator inspection report and has concluded that you have provided the required information outlined by the technical specifications and that there are no items that require followup. It should be noted that Oconee, Unit 2 steam generators will be replaced at the end-of-cycle 20 during the Spring 2004 outage.

Sincerely,

/RA/

Leonard N. Olshan, Project Manager, Section 1 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-270 cc: See next page

February 18, 2004 Mr. Ronald A. Jones Vice President, Oconee Site Duke Energy Corporation 7800 Rochester Highway Seneca, SC 29672

SUBJECT:

OCONEE NUCLEAR STATION, UNIT 2 - REVIEW OF FALL 2002, END-OF-CYCLE 19 STEAM GENERATOR INSPECTION REPORT (TAC NO. MC0906)

By letters dated November 12 and December 5, 2002, February 10 and February 12, 2003, you submitted reports summarizing the steam generator tube inspections performed in the Fall 2002 end-of-cycle 19 refueling outage. In addition, your staff and the Nuclear Regulatory Commission (NRC) staff participated in conference calls during the steam generator inspection activities; our summary of these conference calls was sent to you by letter dated February 25, 2003.

The NRC staff formally reviews all steam generator inspection summary reports submitted by licensees in accordance with the plants technical specification requirements. The NRC staff has reviewed your steam generator inspection report and has concluded that you have provided the required information outlined by the technical specifications and that there are no items that require followup. It should be noted that Oconee, Unit 2 steam generators will be replaced at the end-of-cycle 20 during the Spring 2004 outage.

Sincerely,

/RA/

Leonard N. Olshan, Project Manager, Section 1 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-270 cc: See next page DISTRIBUTION:

PUBLIC PDII-1 R/F RidsNrrDlpmpdii-1 (JNakoski)

CHawes (Hard Copy)

RidsNrrPMLOlshan RidsOgcRp RidsAcrsAcnwMailCenter ADAMS: ML040490044

  • No major changes to SE OFFICE PDII-1 PDII-1 EMCE/SC*

PDII-1/SC NAME LOlshan CHawes LLund JNakoski DATE 2/18/04 2/18/04 01/27/04 2/18/04 OFFICIAL RECORD COPY

Oconee Nuclear Station cc:

Ms. Lisa F. Vaughn Duke Energy Corporation Mail Code - PB05E 422 South Church Street P.O. Box 1244 Charlotte, North Carolina 28201-1244 Anne W. Cottingham, Esquire Winston and Strawn 1400 L Street, NW Washington, DC 20005 Manager, LIS NUS Corporation 2650 McCormick Drive, 3rd Floor Clearwater, Florida 34619-1035 Senior Resident Inspector U. S. Nuclear Regulatory Commission 7812B Rochester Highway Seneca, South Carolina 29672 Mr. Henry Porter, Director Division of Radioactive Waste Management Bureau of Land and Waste Management Department of Health and Environmental Control 2600 Bull Street Columbia, South Carolina 29201-1708 Mr. Michael A. Schoppman Framatome ANP 1911 North Ft. Myer Drive Suite 705 Rosslyn, VA 22209 Mr. B. G. Davenport Regulatory Compliance Manager Oconee Nuclear Site Duke Energy Corporation ON03RC 7800 Rochester Highway Seneca, South Carolina 29672 Ms. Karen E. Long Assistant Attorney General North Carolina Department of Justice P. O. Box 629 Raleigh, North Carolina 27602 Mr. R. L. Gill, Jr.

Manager - Nuclear Regulatory Issues and Industry Affairs Duke Energy Corporation 526 South Church Street Mail Stop EC05P Charlotte, North Carolina 28202 Mr. Richard M. Fry, Director Division of Radiation Protection North Carolina Department of Environment, Health, and Natural Resources 3825 Barrett Drive Raleigh, North Carolina 27609-7721 Mr. Peter R. Harden, IV VP-Customer Relations and Sales Westinghouse Electric Company 6000 Fairview Road 12th Floor Charlotte, North Carolina 28210