ML040280024

From kanterella
Jump to navigation Jump to search

Transmittal of Derived Concentration Guidelines Level (Dcgl) and Area Factor Calculations for License Termination Plan (Ltp)
ML040280024
Person / Time
Site: Yankee Rowe
Issue date: 01/19/2004
From: Kay J
Yankee Atomic Electric Co
To:
Document Control Desk, NRC/FSME
References
-RFPFR, BYR 2004-004, YA-CALC-00-004-03, YA-CALC-00-005-03, YA-CALC-00-006-03, YA-CALC-00-010-03, YA-CALC-01-002-03
Download: ML040280024 (1)


Text

YANKEE ATOMIC ELECTRIC COMPANY Telephone (413) 424-5261 49 Yankee Road, Rowe, Massachusetts 01367 AKEE January 19, 2004 BYR 2004-004 Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

Reference:

(a) License No. DPR-3 (Docket No. 50-29)

Subject:

Derived Concentration Guidelines Level (DCGL) and Area Factor Calculations for License Termination Plan (LTP)

This letter provides a copy of calculations in support of the LTP for the Yankee Nuclear Power Station (YNPS). A hardcopy of each calculation is enclosed as well as a CD which contains an electronic copy of the attachment files. The specific calculations provided are as follows:

(1) YA-CALC-01-002-03, "DCGLs for Soil at the Yankee Rowe Site" (2) YA-CALC-00-004-03, "Building Surface DCGLs" (3) YA-CALC-00-005-03, "Building Surface Area Factors" (4) YA-CALC-00-006-03, "Determination of Area Factors for Soil at YNPS Site" (5) YA-CALC-00-010-03, "Evaluation of Dose Integration Parameter in RESRAD-BUILD These calculations are provided for your review. If you have any questions, please contact us.

Sincerely, YANKEE ATOMIC ELECTRIC COMPANY es A. Kay Principal Licensing Engineer cc: J. Hickman, NRC, Senior Project Manager, NMSS (2 copies)

R. Gallaghar, MA DPH D. Howland, MA DEP M. Rosenstein, EPA, Region 1 W. Perlman, Executive Committee Chair, FRCOG T. W. Hutcheson, Chair, Franklin Regional Planning Board PM1¶S5O I D. Katz, CAN