December 12, 2003 Mr. Ronald A. Jones Vice President, Oconee Site Duke Energy Corporation 7800 Rochester Highway Seneca, SC 29672
SUBJECT:
OCONEE NUCLEAR STATION, UNIT 1 - REVIEW OF END OF CYCLE 20 STEAM GENERATOR INSPECTION REPORT (TAC NO. MB6415)
Dear Mr. Jones:
By letters dated April 25, May 21, and July 11, 2002, you submitted reports summarizing the steam generator tube inspections for Oconee, Unit 1, that were performed in Spring 2002 during the end-of-cycle 20 refueling. In addition, your staff and the Nuclear Regulatory Commission (NRC) staff participated in conference calls during the steam generator inspection activities. The summary of these conference calls was sent to you by letter dated October 29, 2002.
The NRC staff formally reviews all steam generator inspection summary reports that are submitted by licensees in accordance with the plants technical specification (TS) requirements.
The NRC staff has reviewed your steam generator inspection reports and has concluded that you have provided the required information outlined by the TSs and that there are no items that require follow up. It should be noted that the Oconee, Unit 1, steam generators were replaced in Fall 2003 during the end-of-cycle 21 refueling outage.
Sincerely,
/RA/
Leonard N. Olshan, Project Manager, Section 1 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-269 cc: See next page
ML033460207 OFFICE PDII-1/PM PDII-1/LA PD11-1/SC NAME LOlshan:sab CHawes JNakoski DATE 12/11/03 12/11/03 12/11/03
Oconee Nuclear Station cc:
Ms. Lisa F. Vaughn Duke Energy Corporation Mail Code - PB05E 422 South Church Street P.O. Box 1244 Charlotte, North Carolina 28201-1244 Anne W. Cottingham, Esquire Winston and Strawn 1400 L Street, NW Washington, DC 20005 Manager, LIS NUS Corporation 2650 McCormick Drive, 3rd Floor Clearwater, Florida 34619-1035 Senior Resident Inspector U. S. Nuclear Regulatory Commission 7812B Rochester Highway Seneca, South Carolina 29672 Mr. Henry Porter, Director Division of Radioactive Waste Management Bureau of Land and Waste Management Department of Health and Environmental Control 2600 Bull Street Columbia, South Carolina 29201-1708 Mr. Michael A. Schoppman Framatome ANP 1911 North Ft. Myer Drive Suite 705 Rosslyn, VA 22209 Mr. L. E. Nicholson Compliance Manager Duke Energy Corporation Oconee Nuclear Site 7800 Rochester Highway Seneca, South Carolina 29672 Ms. Karen E. Long Assistant Attorney General North Carolina Department of Justice P. O. Box 629 Raleigh, North Carolina 27602 Mr. C. Jeffrey Thomas Manager - Nuclear Regulatory Licensing Duke Energy Corporation 526 South Church Street Charlotte, North Carolina 28201-1006 Mr. Richard M. Fry, Director Division of Radiation Protection North Carolina Department of Environment, Health, and Natural Resources 3825 Barrett Drive Raleigh, North Carolina 27609-7721 Mr. Peter R. Harden, IV VP-Customer Relations and Sales Westinghouse Electric Company 6000 Fairview Road 12th Floor Charlotte, North Carolina 28210