November 14, 2003
Duke Energy Corporation
ATTN: Mr. Ronald A. Jones
Vice President
Oconee Site
7800 Rochester Highway
Seneca, SC 29672
SUBJECT:
OCONEE NUCLEAR PLANT - NRC EXAMINATION INITIAL RETAKE
EXAMINATION REPORT 05000269/2003302, 05000270/2003302 AND
Dear Mr. Jones:
On October 17, 2003, the Nuclear Regulatory Commission (NRC) administered a simulator
portion of the examination to two employees of your company who had applied for licenses to
operate the Oconee Nuclear Plant (one Reactor Operator (RO) and one Senior Reactor
Operator (SRO)). The NRC waived the written and the walkthrough portions of the examination
for both applicants based on satisfactory performance on a previous NRC examination. At the
conclusion of the examination, the examiners discussed the examination and preliminary
findings with those members of your staff identified in the enclosed report. Both applicants
passed the simulator examination. There were no post examination comments.
No findings of significance were identified.
In accordance with 10 CFR 2.790 of the NRCs Rules of Practice, a copy of this letter and its
enclosure will be available electronically for public inspection in the NRC Public Document Room
or from the Publicly Available Records (PARS) component of NRCs document system (ADAMS).
ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the
Public Electronic Reading Room).
Should you have any questions concerning this letter, please contact me at (404) 562-4638.
Sincerely,
/RA/
Michael E. Ernstes, Chief
Operator Licensing and
Human Performance Branch
Division of Reactor Safety
Docket Nos.: 50-269, 50-270, 50-287
License Nos.: DPR-38, DPR-47, DPR-55
Enclosure: (See page 2)
2
Enclosure:
Report Details
cc w/encl:
L. E. Nicholson
Compliance Manager (ONS)
Duke Energy Corporation
Electronic Mail Distribution
Lisa Vaughn
Legal Department (PB05E)
Duke Energy Corporation
422 South Church Street
P. O. Box 1244
Charlotte, NC 28201-1244
Anne Cottingham
Winston & Strawn LLP
Electronic Mail Distribution
Beverly Hall, Acting Director
Division of Radiation Protection
N. C. Department of Environmental
Health & Natural Resources
Electronic Mail Distribution
Henry J. Porter, Director
Div. of Radioactive Waste Mgmt.
S. C. Department of Health and
Environmental Control
Electronic Mail Distribution
R. Mike Gandy
Division of Radioactive Waste Mgmt.
S. C. Department of Health and
Environmental Control
Electronic Mail Distribution
County Supervisor of
Oconee County
415 S. Pine Street
Walhalla, SC 29691-2145
Lyle Graber, LIS
NUS Corporation
Electronic Mail Distribution
M. T. Cash, Manager
Regulatory Issues & Affairs
Duke Energy Corporation
526 S. Church Street
Charlotte, NC 28201-0006
Peggy Force
Assistant Attorney General
N. C. Department of Justice
Electronic Mail Distribution
Mr. Bentley K. Jones
Training Manager
Oconee Nuclear Station
7800 Rochester Highway
Seneca, SC 29672-0752
Distribution w/encl:
L. Olshan, NRR
C. Evans (Part 72 Only)
L. Slack, RII EICS
RIDSNRRDIPMLIPB
PUBLIC
OFFICE
RII:DRS
RII:DRS
RII:DRP
SIGNATURE
/RA/
/RA/
/RA/
NAME
KODonohue:pmd MErnstes
RHaag
DATE
11/13/2003
11/13/2003
11/13/2003
E-MAIL COPY?
YES
NO YES
NO YES
NO YES
NO YES
NO
OFFICIAL RECORD COPY DOCUMENT NAME: C:\\ORPCheckout\\FileNET\\ML033220034.wpd
Enclosure
NUCLEAR REGULATORY COMMISSION
REGION II
Docket Nos.:
50-269, 50-270, 50-287
License Nos.:
Report Nos.:
05000269/2003302, 05000270/2003302 and
Licensee:
Duke Energy Corporation
Facility:
Oconee Nuclear Station
Location:
7800 Rochester Highway
Seneca, SC 29672
Date:
Operating Tests - October 17, 2003
Examiners:
Kathleen ODonohue, Senior Reactor Inspector
Richard Baldwin, Senior Operations Engineer
Approved by:
Michael E. Ernstes, Chief
Operator Licensing and Human Performance Branch
Division of Reactor Safety
SUMMARY OF FINDINGS
ER 05000269/2003302, ER 05000270/2003302, ER 05000287/2003302; 10/17/03; Oconee
Nuclear Station; Licensed Operator Examinations.
NRC examiners conducted an Initial License Retake examination in accordance with the
guidance of NUREG-1021, Draft Revision, Operator Licensing Examination Standards for
Power Reactors. This examination implemented the operator licensing requirements identified
in 10 CFR §55.45.
The NRC administered the Simulator portion of the examination to one Reactor Operator (RO)
and one Senior Reactor Operator (SRO). The scenarios were developed by the licensee. The
NRC waived the written and the walkthrough portions of the examination for both applicants.
Both applicants passed and were issued a license.
No significant issues were identified.
Report Details
4.
OTHER ACTIVITIES (OA)
4OA5 Operator Licensing Initial Examinations
a.
Inspection Scope
The examiners reviewed the simulator scenarios developed by the licensee for
compliance with the guidelines specified in NUREG 1021, Operator Licensing
Examination Standards for Power Reactors, Draft Revision 9. The examination
changes agreed upon between the NRC and the licensee were made according to
NUREG-1021 and incorporated into the final version of the examination materials.
The examiners reviewed the licensees examination security measures while preparing
and administering the examinations to ensure examination security and integrity
complied with 10 CFR 55.49, Integrity of examinations and tests.
The examiners evaluated one Reactor Operator (RO) applicant and one Senior Reactor
Operator (SRO) applicant who were being assessed under the guidelines specified in
NUREG-1021. The examiners administered the operating tests on October 17, 2003.
The evaluations of the applicants and review of documentation were performed to
determine if the applicants met requirements specified in 10 CFR Part 55.
b.
Findings
No findings of significance were identified.
While performing scenario validation on the examination material, the licensee
inadvertently left exam material inadequately secured. The simulator operation
instructions for one of the exam scenarios was left unattended in the simulator over a
period of days. The instructions contained sufficient information on the scenario to
compromise several of the scenario component failures. The licensee regained control
of the material and notified the NRC. The NRC reviewed the details of this incident and
determined that it was a potential compromise to the exam. The compromised
information was deleted from the scenario, it was replaced with new component failures
and the revised scenario was validated. The issue was documented in the licensees
problem identification process as PIP #O-03-06125.
The licensees examination submittal was within the range of acceptability expected for
a proposed examination. One RO and one SRO passed the operating examinations.
There were no post examination comments.
2
4OA6 Meetings
Exit Meeting Summary
On October 17, 2003, the examination team discussed generic issues with Mr. Regis
Repko and members of his staff. The inspectors asked the licensee whether any
materials examined during the inspection should be considered proprietary. No
proprietary information was identified.
PARTIAL LIST OF PERSONS CONTACTED
Licensee personnel
R. Repko, Operations Superintendent
N. Clarkson, Senior Engineer
J. Steely, Initial Training Supervisor
N. Constance, Operations Training Manager
M. Hill, Operations Shift Manager
G. Washburn, nuclear instructor
R. Robinson, Nuclear Shift Supervisor
P. Gillespie, Shift Operations Manager