October 21, 2003 LICENSEE:

Pacific Gas and Electric Company FACILITY:

Diablo Canyon Nuclear Power Plant, Units 1 and 2

SUBJECT:

SUMMARY

OF MEETING HELD ON OCTOBER 7, 2003, TO DISCUSS STEAM GENERATOR ISSUES On October 7, 2003, representatives of Pacific Gas and Electric Company (PG&E) met with the NRC staff to make a presentation on steam generator (SG) issues for Diablo Canyon Nuclear Power Plant, Units 1 and 2.

The meeting began with PG&Es discussion of the license amendment request (LAR) currently being reviewed by the NRC staff for the use of the probability of prior cycle detection (POPCD) method for Unit 2 Cycle 12 operational assessment. The meeting continued with a presentation on the use of a permanent POPCD for future cycles, PG&Es strategy for SG operation until replacement, and planned chemical cleaning of the SGs. PG&E further discussed the wedge region alternate repair criteria exclusion zone reduction, increase of main steam line break (MSLB) leak rate limit, Alloy 800 sleeving and related future LAR, increase of 15 percent plugging limit, and locking of the tube support plate (TSP) to prevent TSP displacement and potential for tube burst under postulated MSLB conditions.

PG&E provided responses to the verbal questions from the NRC staff and discussed tentative schedules for submittal of the future LARs on the subjects discussed in the meeting.

An attendance list is provided in the attachment. The presentation slides used during the meeting are available in ADAMS under Accession No. ML032820023.

/RA/

Girija S. Shukla, Project Manager, Section 2 Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-275 and 50-323

Attachment:

Attendance List cc w/att: See next page

ML032940689 NRC-001 OFFICE PDIV-2/PM PDIV-2/LA PDIV-2/SC NAME GShukla:sab EPeyton SDembek DATE 10/20/03 10/17/03 10/21/03

MEETING ATTENDEES MEETING WITH PACIFIC GAS AND ELECTRIC COMPANY TO DISCUSS STEAM GENERATOR ISSUES FOR DIABLO CANYON OCTOBER 7, 2003 PACIFIC GAS & ELECTRIC S. Ketelsen J. Arhar T. Baldwin D. Beals WESTINGHOUSE T. Pitterle B. Keating R. Smith M. Hu FRAMATOME J. Fleck NRC S. Dembek G. Shukla L. Lund C. Khan K. Karwoski S. Long K. Manoli J. Wu T. Chan

Diablo Canyon Power Plant, Units 1 and 2 cc:

NRC Resident Inspector Diablo Canyon Power Plant c/o U.S. Nuclear Regulatory Commission P.O. Box 369 Avila Beach, CA 93424 Mr. Pete Wagner Sierra Club California 2650 Maple Avenue Morro Bay, California 93442 Ms. Nancy Culver San Luis Obispo Mothers for Peace P.O. Box 164 Pismo Beach, CA 93448 Chairman San Luis Obispo County Board of Supervisors Room 370 County Government Center San Luis Obispo, CA 93408 Mr. Truman Burns Mr. Robert Kinosian California Public Utilities Commission 505 Van Ness, Room 4102 San Francisco, CA 94102 Diablo Canyon Independent Safety Committee ATTN: Robert R. Wellington, Esq.

Legal Counsel 857 Cass Street, Suite D Monterey, CA 93940 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission Harris Tower & Pavillion 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-8064 Richard F. Locke, Esq.

Pacific Gas & Electric Company P.O. Box 7442 San Francisco, CA 94120 Mr. David H. Oatley, Vice President and General Manager Diablo Canyon Power Plant P.O. Box 56 Avila Beach, CA 93424 City Editor The Tribune 3825 South Higuera Street P.O. Box 112 San Luis Obispo, CA 93406-0112 Mr. Ed Bailey, Radiation Program Director Radiologic Health Branch State Department of Health Services P.O. Box 942732 (MS 178)

Sacramento, CA 94234-7320 Mr. James D. Boyd, Commissioner California Energy Commission 1516 Ninth Street (MS 31)

Sacramento, CA 95814 Mr. James R. Becker, Vice President Diablo Canyon Operations and Station Director Diablo Canyon Power Plant P.O. Box 3 Avila Beach, CA 93424 Mr. Gregory M. Rueger Senior Vice President, Generation and Chief Nuclear Officer Pacific Gas and Electric Company Diablo Canyon Power Plant P.O. Box 3 Avila Beach, CA 93424