Site Safety Analysis Report for the Exelon Generation Company, LLC Early Site Permit, Appendix B, Seismic Hazards Report, Attachment 1, Figures B-1-6 Through B-1-11
ML032730609
Person / Time
Site: Clinton, 05200007, PROJ0718  Constellation icon.png
Issue date: 09/25/2003
From:
Exelon Generation Co, Exelon Nuclear
To:
Office of New Reactors
Shared Package
ML032721596 List:
References
+ReviewedClintonESP, +reviewednvg DEL-096-REV0
Download: ML032730609 (5)


Text

From: Hansel and Johnson (1996)

Site B-1-7 Seismic Hazards Report for the EGC ESP Site Areal Distribution of the Wedron and Mason Groups (Wisconsin and Hudson Episodes) and Deposits of the Illinois and Pre-Illinois Episodes in Illinois s:\\7900\\7935\\7935.000\\03_0303_sectb1\\_fig_b1-07(01).ai (2003-05-29, 11:00)

Figure

Modified from: Hansel and Johnson (1996)

Site B-1-8 Seismic Hazards Report for the EGC ESP Site Areal distribution of moraines and boundaries of formations and principal members of the Wedron group s:\\7900\\7935\\7935.000\\03_0303_fr\\_fig_a-08(15).ai (2003-05-28, 11:18)

Figure

From: Hansel and Johnson (1996)

B-1-9 Seismic Hazards Report for the EGC ESP Site Geochronologic Units, Chronostratigraphic Units and Diachronic Units in the Lake Michigan Lobe s:\\7900\\7935\\7935.000\\03_0303_sectb1\\_fig_b1-09(02)_xsect.ai (2003-05-29, 11:02)

Figure

Younger soil is developed on lower terrace. Note the lack of oxidation near the water level Animal trail Oxidized Pre-hypsithermic soil developed on higher, older terrace Approximate backedge to younger terrace

~12 ft B-1-10 Seismic Hazards Report for the EGC ESP Site Photograph of Riverbank Exposure on Salt Creek Showing Fluvial Terrace Deposits of Two Ages s:\\7900\\7935\\7935.000\\03_0303_sectb1\\_fig_b1-10(08).ai (2003-05-29, 11:03)

Figure

0 20 Miles 10 Scale 1:500,000 0

20 10 Kilometers Carmi Member of Equality Formation Dolton Member of Equality Formation Mackinaw Member of Henry Formation Batavia Member of Henry Formation Wasco Member of Henry Formation Yorkville Till Member of Wedron Group Snider Till Member of Wedon Group Batestown Till Member of Wedron Group Site Formation boundary within the Wedron Group (from Hansel and Johnson, 1996; see Figure B-1-8)

Platt Till Member of Wedron Group Tiskilwa Till Member of Wedron Group Delavan Till Member of Wedron Group Fairgrange Till Member of Wedron Group Moraine Hagarstown Member of Glasford Formation Radnor Till Member of Glasford Formation Vandalia Till Member of Glasford Formation Member boundary within the Wedron Group (from Hansel and Johnson, 1996; see Figure B-1-8) ec ed hm hb hw wy ws wb wp wt wd wf morraine gha gr gv T I S K I L W A F O R M A T I O N L E M O N T F O R M A T I O N Notes

1. Modified from Lineback, 1979
2. More recent studies (Hansel and Johnson, 1996) reassign several members of the Wedron Group to better match moraine morphology. These new formation and member boundaries are shown here and on Figure B-1-8).

Therefore, some map units on this figure may not agree with current formation and member boundaries within the Wedron Group.

Lemont Formation Tiskilwa Formation Seismic Hazards Report for the EGC ESP Site Map Of Quaternary Deposits In The Site Vicinity s:\\7900\\7935\\7935.000\\03_0303_sectb1\\_fig_b1-11(01).ai (2003-05-29, 11:06)

Figure B-1-11