Draft Submittal WATTS BAR EXAM 2002-301 50-390 NOVEMBER 26 &
DECEMBER 9 - 13,2002
- 1.
- 2.
- 3.
- 4.
- 5.
Administrative QuestionslJPMs In-plant JPMs Control Room JPMs (simulator JPMs)
Administrative Topics Outline ES-301-1 Control Room Systems and Facility Walk-Through Test Outline ES-301-2
ES-301 Administrative Topics Outline Form ES-301-1 (R8, S1)
A.2 Facility: -Watts Bar Examination Level (circle one): RO I SRO Equipment Control Administrative Topic/Subject Description Conduct of Operations Medical Emergency Response (RO) (NEW)
A.3 1
Radiation Control A.4 I Emergency Date of Examination: -1 1/9-13/02-Operating Test Number:
1 Describe method of evaluation:
- 2. TWO Administrative Questions
- a. Calculate the Estimated Critical Position (NEW)
- b. Complete Shift Turn Over Checklist (NEW)
I Complete Shift Daily Surveillance Log Mode One and Evaluate Surveillance Log. (NEW)
Access a High Radiation Area (NEW)
Classify the Event per the REP (Security Event)-SRO (NRC-JPM-NEW)
A.l a Calculate Estimated Critical Position Initial Conditions:
The unit is shutdown and maintenance has completed repairs. Plant management has approved recommendations to restart.
Referenced Documents:
1-SI-0-1 1, Estimated Critical Position Task Standard:
Correctly perform a hand calculation of the estimated critical position (ECP) and determine the ECP to be within acceptance criteria.
lnitiatina Cues:
You have been tasked to perform a calculation of the estimated critical position using Previous At-Power Data. REACT and REACTIN software are not available for use.
When the ECP has been calculated and acceptability has been determined.
NOTE Data for ECP should be provided. Reactor has operated at 100% for greater than 30 days.
The ECP hand calculation should use Previous At-Power Data. Data from the Reactor Trip Data Book will need to be provided. Expected Core average temperature at startup and expected boron concentration at startup will also need to be provided. NuPOP ECP calculation worksheets Table 7-16 should be supplied.
A.l b Shift Turnover Initial Conditions:
See below.
Referenced Documents:
OPDP-1, Conduct of Operations Task Standard Correctly complete the shift turnover checklist.
lnitiatina Cues:
It is four hours into the shift. You as the Unit Operator At the Controls have been directed to be relieved the an extra qualified operator. You have been informed that you will be gone for the remainder of the shift.
Terminatina Cues:
When the Shift turnover form is complete.
NOTE:
Provide an expected listing of abnormal equipment; surveillance tests; major activities and procedures in progress: radiological change that would be used to complete a shift turnover form.
A.2 Shift and Daily Surveillance Log Mode One and Evaluation of Surveillance Test Results Initial Conditions:
Shift and Daily Surveillance Log Mode One has been not been completed.
Referenced Documents:
1 -SI-0-2B-0II Shift and Daily Surveillance Log Mode One Task Standard:
Correctly record data on data sheet 1 reference 11, 12, and 1 3 and review completed data sheets to determine the surveillance does not pass the acceptance criteria.
Initiating Cues:
You are the RO responsible to perform and review the Shift Daily Surveillance Log Mode 1.
Portions of the log have been completed for you. You are to complete reference 11, 12, and 1 3 and verify all of acceptance criteria have been met for Shift Daily Surveillance Log Mode 1.
Terminatinq Cues:
When the data sheet 1 reference 11, 12, and 1 3 data has been collected and acceptability of Shift Daily Surveillance Log Mode 1 has been determined.
NOTE:
Data for all portions of the surveillance should be filled in with the exception of 11, 12, and 13.
The results of the surveillance should contain some readings close to the acceptance criteria as well as at least one outside the criteria.
Surveillance dealing with 1-SI-0-2B-01, Shift Daily Surveillance Log Mode 1.
A.3 Access a High Radiation Area Initial Conditions:
Unit requirements are such that you are directed to make all arrangements to enter a very high radiation area.
Referenced Documents:
Task Standard:
Correctly identify the actions necessary to enter a very high radiation area.
lnitiatina Cues:
Current unit conditions require you to enter a very high radiation area. Your estimated time in the very high radiation area will be 5 minutes. You are directed to make all arrangements to enter the very high radiation area.
Terminatina Cues:
When all arrangements have been made to enter the very high radiation area.
NOTE Provide a list of forms, actions and keys necessary to complete this task.
A.4 RO Medical Emergency Response Initial Conditions:
Normal plant operations is in progress.
Referenced Documents:
EPIP-IO, Medical Emergency Response Task Standard Correctly complete EPIP-10 Appendix A Control Room Operator Medical Response Checklist lnitiatinq Cues:
You as the Unit Operator in the control room receive a call notifying you of a medical emergency has occurred. As the Unit Operator in the control room complete any action required for this situation.
Terminatinq Cues:
When EPIP-I 0 Appendix A, Control Room Operator Medical Response Checklist is complete.
NOTE:
Provide the necessary information to complete the Medical Response checklist.
/
- b. Rolling lb-b Diesel Generator for Water in Cylinders per Sol-82.02 (JPM #048)
- c. Perform LOCAL restart of Control and Service Air compressors per AOI-10 (3-OT-JPMA001C)
ES-301 Control Room Systems Form ES-301-2 (R8, Si) and Facility Walk-Through Test Outline D
6 DA 8
Facility: -Watts Bar Exam Level (circle one): RO / SROII) / SROW)
B.l Control Room Systems Date of Examination: -1 2/9-13/02-Operating Test No.:
1 System I JPM Title
- d. Respond to a High Containment Pressure
- e. Transfer Steam Dumps to Tavg Mode (NRC-JPM-New)
- f. Retrieve a Dropped Rod per AOI-2 (JPM #95A)
- g. Remove SRM N132 from Service (NRC-JPM-New)
B.2 Facility Walk-Through Safety Code*
Function 3
1
- a. Respond to steam binding of 1 A-A-AFW pump per 1
DR -1 s
Sol-3.02 (3-OT-JPMA065)
- Type Codes: (D)irect from bank, (M)odified from bank, (N)ew, (A)lternate path, (C)ontrol room, (S)imulator, (L)ow-Power, (R)CA
-____ WATTS BAR NUCLEAR PLANT NRC-JPM-NEW TITLE:
TRANSFER STEAM DUMPS TO Tavg MODE PER GO-3 WRITTEN BY:
/
VALIDATED BY:
APPROVED BY:
(OPERATIONS TRAINING)
CONCURRENCE:
(OPERATIONS REPRESENTATIVE)
WATTS BAR NUCLEAR PLANT
-~
NRC-JPM-NEW EVALUATION SHEET Task: Transfer Steam Dumps To Tavg Mode Per GO-3 Alternate Path:
WA Ratinals):
041A4.03 G2.1.20 Task Standard:
Steam Dump Valves have been transferred to the STEAM PRESSURE MODE, and controlling without inadvertent overcooling of the RCS (> 10°F).
Preferred Evaluation Location:
Preferred Evaluation Method:
Simulator X In-Plant -
Perform ' X Simulate -
References:
GO-3 Unit Startup from less than 4% Reactor Power to 30% Reactor Power Task Number::
APPLICABLE FOR: ROISRO 10CFR55.45: 1,2,4,5,6, 7 Validation Time:. Time Critical: No Candidate:
Time Start:
NAME SSN Time Finish:
Performance Ratinq SAT __ UNSAT __
Performance Time -
Examiner:
I NAME SIGNATURE DATE COMMENTS
WATTS BAR _-- NUCLEAR PLANT NRC-JPM-NEW SIMULATOR OPERATOR INSTRUCTIONS:
- 1. Initialize to IC #
Acknowledge all alarms.
FREEZE the simulator till the performer indicates an understanding of the task.
- 5.
NOTE: This JPM has been pre-shot in IC #. Should IC # be erased or fail to perform as expected then use the following set-up instructions:
Initialize the simulator in IC #
Permissive 66-E, C-7 LOSS OF LOAD STM DUMP INTERLOCK is LIT Complete Actions of GO-3 up to section 5.4 step 2.
Freeze simulator.
SIMULATOR OPERATOR INSTRUCTIONS:
NONE
WATTS BAR NUCLEAR PLANT NRC-JPM-NEW Tools/Eauipment/Procedures Needed:
Ensure a clean copy of GO-3 is on the Simulator Floor. Ensure all steps up to step 5.4.2 are signed off.
[COMMENT1 J READ TO OPERATOR DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.
INITIAL CONDITIONS:
The Unit is in startup between 20 and 24% reactor power.
Plant is at normal operating temperature and pressure via steam dumps.
You are the Control Room Operator.
INITIATING CUES:
You are directed by the Unit Supervisor to transfer the steam dump valves to Tavg MODE per the GO-3 Section 5.2 step 2.
You are to notify the Unit Supervisor when the transfer is complete.
REV. 3PAGE 5 OF 11 WATTS BAR NUCLEAR PLANT NRC - JPM - New START TIME:
[COMMENT21 STEP 1:
Obtain a copy of the appropriate instruction.
STANDARD: A copy of GO-3 has been obtained.
EXAMINER'S CUE: The evaluator to provide a copy of the instruction wit/
steps signed off to 5.42.
COMMENTS:
STEP 2:
Monitor the following:
oTavg following Tref program RCP seal flow between 8 and 13 gpm per pump PZR level on program
- All RPls, Step Counters, Loop AT, and NIS for correct pov distribution, quadrant power tilts, rod insertion, rod misalign inoperable RPls, and inoperable rods.
STANDARD: All parameters are within their program bands.
COMMENTS:
- Italicized Cues Are To Be Used Only If JPM Performance Is Being Simulated.
REV. 3PAGE 6 OF 11 WATTS BAR NUCLEAR PLANT NRC - JPM - New STEP 3:
Compare Tavg, AT, and NIS to verify indications are consistent with expected values.
STANDARD: Tavg, AT, and NIS are consistent with expected values.
COMMENTS:
I CRITICAL STEP -
SAT UNSAT STEP 4:
When Turbine load is greater than 15% Then
- Verify Permissive 66-A, C-5 LO TURB IMPULSE PRESS ROD BLOCK, is NOT LIT.
- If auto rod control is desired, THEN Place rod control in AUTO per Sol-85.01.
CUE: Auto Rod Control is nor desired.
STANDARD: Permissive 66-A, C-5 LO TURB IMPULSE PRESS ROD BLOCK, is NOT LIT. Rod Control left in manual.
COMMENTS:
SAT UNSAT
- Italicized Cues Are To Be Used On/y I f JPM Performance Is Being Simulated.
~~~~
REV. 3PAGE 7 OF 11 WATTS BAR NUCLEAR PLANT NRC - JPM - New
~-
STEP 5:
When steam dump demand (1-XI-1-33) reduces to zero, then transfer Steam Dumps to Tavg mode by performing the following:
STANDARD: Steam Dump demand indicator 1-XI-1-33 is verified to be reading zero prior to continuing.
COMMENTS:
STEP 6:
[STEP 5a ] PLACE steam dump controls OFF:
l-HS-l-l03A, STM DUMP FSV A.
1-HS-1-1038, STM DUMP FSV 6.
STANDARD:
B 1 -HS-1-1036 are placed to the OFF position.
Steam Dump FSV A 1 -HS-l-l03A & FSV COMMENTS:
STEP 7:
[Step 5b] Place l-HS-l-l03D, Steam Dump MODE to Tavg.
STANDARD: l-HS-l-l03D,Steam Dump MODE is selected to Tavg.
COMMENTS:
STEP 8:[STEP 5c]
If Permissive 66-E, C-7 LOSS OF LOAD STM DUMP INTERLOCK, is LIT, THEN CRITICAL STEP SAT UNSAT CRITICAL STEP SAT UNSAT CRITICAL STEP SAT UNSAT CRITICAL STEP
- Italicized Cues Are To Be Used Only If JPM Performance Is Being Simulated.
REV. 3PAGE 8 OF 11 WATTS
~ ~.. BAR NUCLEAR
~~~
PLANT NRC - JPM - New
~~
- Momentarily Place 1-HS-1-103D to RESET
- Verify Permissive 66-E is NOT LIT STANDARD:
1-HS-1-103D is placed in reset and permissive 66-E is not lit.
COMMENTS:
STEP 9: [STEP 5d] ADJUST 1-PIC-1-33, STEAM DUMP PRESS CONTROL, to 84%
and place in AUTO STANDARD:
I-PIC-1-33, STEAM DUMP PRESS CONTROL is adjusted to 84% and placed in AUTO.
COMMENTS:
STEP 6:
[STEP 5a ] PLACE steam dump controls ON:
l-HS-I-l03A, STM DUMP FSV "A.
1 -HS-I-l03B, STM DUMP FSV "B".
STANDARD:
" B 1 -HS-1-103B are placed to the ON position.
Steam Dump FSV " A 1 -HS-I -1 03A & FSV I
COMMENTS:
SAT UNSAT CRITICAL STEP SAT UNSAT CRITICAL STEP SAT UNSAT
- Italicized Cues Are To Be Used Only If JPM Performance Is Being Simulated.
~
REV. 3PAGE 9 OF 11 WATTS BAR NUCLEAR PLANT NRC - JPM - New
~
_ ~ ~ _ _ _
STEP 10:
Notify the Unit Supervisor that the steam dump valves have been transferred to the Tavg mode.
STANDARD: The Unit Supervisor is notified that the steam dump valves have been transferred to the Tavg mode.
COMMENTS:
END OF TASK TIME STOP:
SAT UNSAT
- Italicized Cues Are 7'0 Be Used Only If JPM Performance Is Being Simulated.
4.
REV. 3PAGE 10 OF 11 WATTS BAR NUCLEAR-PL-ANT-CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.
INITIAL CONDITIONS:
The Unit is in startup between 20 and 24% reactor power.
Plant is at normal operating temperature and pressure via steam dumps.
You are the Control Room Operator.
INITIATING CUES:
You are directed by the Unit Supervisor to transfer the steam dump valves to Tavg MODE per the GO-3 Section 5.2 step 2.
You are to notify the Unit Supervisor when the transfer is complete.
REV. 0
~
TASK TITLE:
PAGE 1 OF 8
. wArrs~ ~ ~ R - ~ r \\ l WCCEAR~P~mT-----.~
RETURN SRM N132 TO SERVICE PER AOI-4 WRITTEN BY :
i VALIDATED BY:
APPROVED B Y (OPERATIONS TRAINING)
CONCURRENCE:
(OPERATIONS REPRESENTATIVE)
REV. 0 PAGE 2 OF 8 REVISION LOG REVISION LOG DATE DESCRIPTION OF CHANGES PAGES AFFECTED 0
10/07/96 INITIAL ISSUE ALL
REV. 0 PAGE 3 OF 8 T7ATTS3AR-N U CLEAR-PlXlT--------
EVALUATION SHEET TASK: RETURN SRM N132 TO SERVICE PER AOl-4 PERFORMER:
DATE:
SSN:
RESULT SATISFACTORY -
UNSATISFACTORY NOTE: COMMENTS ARE MANDATORY FOR UNSATISFACTORY RESULTS
- ,*t*******ttt*******t++***""***ttt**.****~"".~***~""~.~***"~"~*""~*~****""""*,*.*"""".~~**""""~**""""*"
- tt+ttt****ttt******Itt******"*.***"~..****""*~***~~"."~.~***~""*****".****"*"**~,~*"*"...~~*"""*.~*"~"**
TASK NUMBER:
AUO-092-AOI-4-001 APPLICABLE FOR: RO/SRO K/A
REFERENCE:
01502OGoO9 (3.4/3.3 015000A4.01 (3.6/3.6) 10CFR55.45: 4, 6,12 ESTIMATED COMPLETION TIME: I mln.
EVALUATION METHOD : SIMULATOR:
X INPLANT COMMENTS:
ACTUAL COMPLETION TIME: -
mln.
i EVALUATOR:
I (SIGNATURE)
(DATE)
REV. 0 PAGE 4 OF 8
_ _ _ _ ~ ~
~.
WAl?S BAR NUC-LEARPMNT EVALUATOR INFORMATION SHEET TASK TITLE:
SIMULATOR SET-UP INSTRUCTIONS RETURN SRM N132 TO SERVICE PER AOI-4 Initialize to IC #
Acknowledge all alarms Freeze simulator until the performer Indicates understanding of the task and time is allowed for control board familiarization.
Note: This JPM has been preshot in IC #
The following is the setup instructlons If needed:
Initialize to IC # conditions for (MODE 4)
Acknowledge all alarms Ensure 1-NR-45 selected to SRM N131 Ensure Shutdown Monitor turned ON and reading countrate.
Start Audio Count Rate on SRM 131.
Freeze simulator until the performer indicates understanding of the task and time is allowed for control board familiarization.
CRITICAL STEPS iDENTlFiED WITH AN ASTERISK r)
TIME CRITICAL TASK: NO ALTERNATE PATH JPM: NO TASK STANDARDS:
Source Range Monitor N132 has been taken out of service in accordance with AOI-4 Section 3.2.
. REQUIRED MATERIALS:
None SAFETY CONSIDERATIONS:
None
REFERENCES:
AOl-4, NUCLEAR INSTRUMENTATION MALFUNCTIONS, (Rev 20)
REV. 0 PAGE 5 OF 8 WATTS-BAR-NUCtErARPLANT PERFORMER INFORMATION SHEET TASK TITLE:
REMOVE SRM N132 FROM SERVICE PER AOI-4
- ttt~+*********tt+*******ttt*****tt+t****"**"**~,*~*"~*.***"***""..~~****""~"""*.~~**""".***"*""""*~**""""
- ttt*********.*ttt******t++****.*t~~~~~~,~~~~~~~*~~.*~~~~~.
READ THE FOLLOWING TO OPERATOR:
I WILL EXPLAIN THE INITIAL CONDITIONS, WHICH STEP(S) TO SIMULATE OR DISCUSS, AND PROVIDE INITIATING/OPERATING CUES.
WHEN YOU COMPLETE THE TASK SUCCESSFULLY, THE OBJECTIVE FOR THIS JOB PERFORMANCE MEASURE WiLL BE SATISFIED.
ENSURE THAT YOU INDICATE TO ME WHEN YOU FULLY UNDERSTAND YOUR TASK.
INITIAL CONDITIONS
- Plant conditions, BOL 4M)"F, 593 psig
- Unit Heat-Up In progress.
- You are the Reactor Operator INITIATING CUES:
- The Unit Supervisor has directed you to remove SRM N132 from service
- You are to notify the US when the procedure has been completed.
REV. 0 PAGE 6 OF 8
WAllS BAR-NUCCEAR-PlXNr-
~
PERFORMANCE STEP 1:
(Cue:
correct instruction, the evaluator can provide a copy of the instruction.)
Obtain the proper procedure.
After the performer has demonstrated the method of obtaining the STANDARD: A copy of AOl-4 has been obtained.
PERFORMANCE STEP 2:
(3.2.5) Place failed channel LEVELTRIP switch to BYPASS (1-M-13).
STANDARD: The failed channe1.N-132, LEVEL TRIP switch placed to BYPASS.
STEP EVALUATION: SAT __ UNSAT -
PERFORMANCE STEP 3:
(3.2.6)
Place failed channel HIGH FLUX AT SHUTDOWN switch to Block STANDARD: channel HIGH FLUX AT SHUTDOWN switch to placed to block PERFORMANCE STEP 4:
(3.2.7) channel Ensure 1-NR-92-145 recording an operable source range STANDARD: 1-NR-92-145 recording selected to an operable source range channel STEP EVALUATION: SAT __ UNSAT __
PERFORMANCE STEP 5:
(3.2.8)
IF in MODE 3, 4, or 5, THEN CHECK audio count rate audible In control room.
REFER TO the following Technical Specifications:
3.3.1, Reactor Trip System Instrumentation 3.3.3, PAM Instruments 3.3.4, Remote Shutdown System (CUE: When the applicant states that he will review Tech Specs, inform him that Tech Specs will be reviewed by another. This ends the JPM)
STANDARD: Plant is in MODE 4. The audio count rate should be audible in the control room. Tech Specs will be reviewed by another.
REV. 0 PAGE 7 OF 8 WATKB'AR NUCEAR-PCA-N7-- -
PERFORMER HANDOUT SHEET
- ,***t****t.*t***t****t+***t*********~*"~~****"",~*~~,*~*~""*~***,.***".~**",~**""~,~****.**""*~~*"***~*~*
- t**.t+**t+**.**t.+***tt***tt***ltt**",,~*""~***~""~,~*",~~***~"**""*.***.~~**"",**"~,,**"*~,~~~~,,****~*~**
THE EXAMINER WILL EXPLAIN THE INITIAL CONDITIONS, WHICH STEP@) TO SIMULATE OR DISCUSS, AND PROVIDE INITIATING/OPERATING CUES.
WHEN YOU COMPLETE THE TASK SUCCESSFULLY, THE OBJECTiVE FOR THIS JOB PERFORMANCE MEASURE WILL BE SATISFIED.
ENSURE THAT YOU INDiCATE TO ME WHEN YOU FULLY UNDERSTAND YOUR TASK.
- tt***t+**tt**,***t,****~***,*"**,*~***,,,*~~~*,**~*,.****~***"***"~~,**"",,~""",,~"""***"""~~*"""***
INITIAL CONDITIONS:
- Plant conditions, BOL 400°F. 593 pslg
- Unit Heat-Up in progress.
- You are the Reactor Operator INiTlATlNG CUES
- The Unit Supervisor has directed you to remove SRM N132 from service.
- You are to notify the US when the procedure has been completed.