Calculation, Main Steam Line Break Accident Done for Vermont Yankee, Psat 3019CF.QA.06
ML032190660
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 07/29/2003
From: Fuller E, Leaver D, Metcalf J
Entergy Nuclear Operations, Entergy Nuclear Vermont Yankee
To:
Office of Nuclear Reactor Regulation
References
BVY 03-70 PSAT 3019CF.QA.06, Rev 0
Download: ML032190660 (18)


Text

PSALT 3019cFA.Qk6 Ps I ofn I.

P L

-7 /2-1 /0-7 CA1LCUL.UQN T=1PAUE CAECMAMN NUMM. PSAT 3019cF.QA0 "J'I

~l;

~~

~LzrDthA~~4tD~cl Vow Yoe MIC MU.~~1CKR

~

R~IEv

£IwaNAMTO RE: 0 I

2

.. D. Leaver 1.Lao 4,

REASONEOB SEVtON-N-

lonconfouu=.wRpt N/A 0-i-

hiftial Issue Correct typos on page 11, NRC modeling discussion

-CONTROLLED CoPYI

PSAT 3019CF.QA.06 Pg2ofl2 Rev 0 Table of Contents Se2ti Page Purpose 2

Summary of Results 2

Methodology Assuptions References Design Inputs Calculation Results Conclusions 3

3 4

4 6

11 12 Appendix A, Rev 0, 'Determination of Whole Body DCF fbr Kr90Y' 3 pages Appendix B, Rev 0, "Compauison of the Calculated Puff XlQ to Preliminary NRC Methods" 3 pages Purpose This calculation analyzes the Main Steam Line Break (MSIB) Accident for Vermont Yankee including (1) both a quasi-steady and a 'puff' X/Q and (2) both offlite and Control Room doses.

Summary of Results Table I - MSLB Summary ofDose Results (ITEDE in Rem*)

Case Control Room**

EAB**

LPZ

1. Turbine Building Ground-Level Release***

1.80/6.55 10.98113.571 <0.981/<3.57

2. Turbine Building Puff Release****

0.5512.00 0.981/3.57

< 0.981/< 3.57 Lmidts as follows: Control Room - s remnTEDE; EARILPZ - 2.5 re=TEDE e 1.1 pigm DE 1131,25 rem TEDE @

4.0 pCi/mp DE 1131

"'For Tech Spec coolant activity 1.1 ICi/gm /4.0 pCi/gm (Le. 3.64 x Tech Spec coolant activity) DE I131

      • Contro Room X/Q calculated using ARCON96
      • "Corol Room XfQ for hemishefical steamrbubble crossing intake at maxn= diameter The offkite cases meet all of the applicable TEDE limits (2.5 rem EAB/LPZ at the normal Tech Spec coolant activity of 1. I jtCilgrn DE II31 and 25 rem EAB/LPZ at the pre-incident spike Tech

PSAT 3019CF.QA.06 Pg 3 of 12 Rev 0 Spec coolant activity of 4.0 pCi/gm). For the Control Room, both cases meet the TEDE limit (5 remn for either Tech Spec coolant activity) for the normal Tech Spec coolant activity, but only Case 2 meets the Control Room TEDE limit for the pre-incident spike Tech Spec coolant activity.

This dose analysis fully complies with NRC Regulatory Guide 1.183 (Reference 1).

Methodology The MSLB accident is initiated from hot stand-by conditions in order to conservatively maximize the mass of coolant released from the break and thus maximizing the activity released. Following accident initiation, the radionuclide inventory from the released coolant is assumed to reach the environment instantaneously (even though in the first case, a X/Q for a quasi-steady plume release is conservatively employed). Two cases are analyzed: Case 1 in which the XQ is for a quasi-steady plume release (as just noted, with the release assumed to be at the turbine stop valves and with no credit taken for Turbine Building holdup) and Case 2 in which the release is assumed to be an instantaneous "puff that then crosses the Control Room air intake at its maximum dimension.

ARCON-96 (Reference 2) has been used to calculate the X/Q for Case 1. The "puffl' XQ for Case 2 has been calculated on the basis of a hemispherical steam cloud (or 'bubble") of uniform density passing over the Control Room air intake. To demonstrate its conservatism, this result is compared to the NRC "puff' X/Q methodology outlined in Reference 3. The BAB X/Q corresponds to a ground-level release without plume rise, the worst-case off Bite receptor (SSW sector, 188.2 m from the Turbine Building), and site-specific meteorology.

Releases account for.

1. Primarycoolantactivitybeingatthe TS lmitof 1.1 zCi/gmDE 1131;
2. Pre-accident noble gas release rate to the atmosphere being at the TS limit of O.16 Ci/sec;
3. Added case with 3.64 times these linits (coverin the 4.0 ICi/gm DE 113124 hour TS limit)

The TEDE values obtained for these analyses are compared with the 2.5/25 rein MSLB TEDE limit for offsite doses and the 5 rem TEDE limit for the Control Room (Reference 1).

Assumptions Assumption 1: There is no holdup in the Tmbine Building.

Justification: Per Reference 1, there should be no holdup credited.

Assumption 2: In the calculation ofthe activity release, the entire released coolant mass is conservatively used (rather than just the liquid mass).

Justification: Reference 4 Assumption 3: There is no fuel damage. Therefore, there is no impact of Extendent Power Uprate or AST on the dose analysis other than the use of TEDE as the dose measure

PSAT 3019CF.QA.06 Pg 4 of 12 Rev 0 Justification:

Reference 4. Since there is no fuel damage, AST has no impact on the activity released. Extended Power Uprate has no impact because the analysis is conducted at zero power hot standby.

Assumption 4 An infinite exchange rate between the Control Room and the environment is assumed.

Justification: Conservative References

1. "Alternative Radiological Source Terms for Evaluating Design Basis Accidents at Nuclear Power Reactors", US NRC Regulatory Guide 1.183, Revision 0, July 2000
2. J.V. Ramsdell Jr., et al., "Atmospheric Relative Concentrations in Building Wakes",

NUREGtCR-6331 Revision 1 (PNNL-10521 Revision 1), May 1997

3. "Atmospheric Relative Concentrations for Control Room Radiological Habitability Assessments at Nuclear Power Plants", US NRC Regulatory Guide 1.194, Revision 0 June 2003
4. VY Calculation VYC-2064, "VY - Radiological Evaluation of a Main Steam Line Break Accident under Hot Standby Conditions", Revision 0
5. PSAT 3019CF.QA.03, "DESIGN DATA BASE FOR APPLICATION OF THE REVISED DBA SOURCE TERM TO VERMONT YANKEE-, Revision 0
6. S. L. Humpbries et al, "RAI)TRAD: A Simplified Model for Radionuclide Tansport and Removal and Dose Estimation", NUREG/CR-6604, Sandia National Laboratories, December 1997.
7. PSAT 3019CF.QA.05, "'Fuel Handling Dose Analysis for Vermont Yankee", Revision 0 Design Inputs Design Input Data (Reference 5 for all inputs except DCFs, Item numbers given in brackets)

Control Room Free Volume: 41,533.75 ft3

[3.4]

XQ values in sec/m 3:

EAB:

1.7E-3 (ground-level)

[5.1]

LPZ:

CR (Case 1) 4.68E-3 (ground-level)

[53]

  • LPZ dose not necessary since release is limited to two hours and EAB is more limiting Breathing Rate in m3/s (from start of release): 3.5E-4 (5.4]

Total mass of vapor and liquid released. 59,500 Ibm

[8.6]

Total mass of vapor only: 21,798 lbm[

18.7]

PSAT 3019CF.QA.06 Reference pressure for flashing: 1045 psia Pg5 of 12 Rev 0 (8.8]

Activity Releases:

Isotope Ci Released Kr83m 3.711E-2 KrS5m 6.658E-2 KiS5 2.183E-4 KrS7 2.183E-1 Kr88 2.183E-1 Kr89 A419 Kr9O 3.056 Xel3lm 1.637E4 Xel33m 3.165E-4 Xel33 8.949E-2 Xel35m 2.838SE-1 Xel3S 2.401E -1 Xel37 1.637 Xel38 9.713E-1 1131 11.88 1132 113.4 1133 80.99

[134 216.0 I135 118.8

[2.13]

Dose Conversion Factors (DCFs from Reference 6 as documented in Reference 7)

Nuclide CR WB CEDE TEDE*

TEDE" KEr83m 1.49E-05 0

1A9E-05 5E-07 Kr85m 0.0277 0

0.0277 0.0009 Kr85 4.40E-04 0

4AOE-04 E-S05 Kr87 0.1524 0

0.1524 0.0047 Kr88 03774 0

0.3774 0.0117 Kr89 0.323 0

0323 0.01 Xcl3lm 0.00149 0

0.00149 SE-05 Xel33m 0.00507 0

0.00507 0.0002 Xe133 0.00577 0

0.00577 0.0002 Xel3Sm 0.07548 0

0.07548 0.0023 Xc135 0.04403 0

0.04403 0.0014 Xe137 0.0303 0

0.0303 0.0009 Xel38 0.199 0

0.199 0.0062 1131 0.06734 32893 11.5799 11.515 I132 0.4144 381.1 0.54779 0.1462 I133 0.10878 5846 2.15488 2.0495 1134 0.481 131.35 0.52697 0.0609 1135 0.3069 1228.4 0.73684 0.4395

  • Based on breathing rate of 3.SE-4 m3/scc "Based on CR volume of 41,533.75 h3

PSAT 3019CF.QA.06 Pg 6 of 12 Rev 0 Calculation The current VY MSLB dose calculation (Reference 4) can be readily benchmarked using a spreadsheet approach. The effective DCF in Table 2 below is the product of the CEDE DGF (rem/Ci) and the breathing rate of 3.5E-4 m3/sec plus the whole body DCF (rem-m3/Ci-sec).

With the exception ofKx9O, the DCFs are identified in the Design Input section. When multiplied by the activity release (Ci) (also identified in the Design Input section), one obtains the nonmalized TEDE impact (rem-m3/sec). This value needs only to be multiplied by the X/Q (the inverse of the atmospheric dilution, sec/m3) to obtain the dose in rem TEDE.

The whole body DCF for Kr9O is not available in References 6 or 7. It has been developed in Appendix A.

Table 2 - Benchmark of VY CLB MSLB Activity Release and Normalized Dose Inpact (EAR)

IsotM Ci Reled CEDE DCF WB DCF EffDCF Norm TEDE Impact Kr83m 3.71E-02 0

1.49E-05 0.0000 0.00 KrS~m 6.66E-02 0

0.0277 0.0277 0.00 Kr85 2.1SE-04 0

4.40E-04 0.0004 0.00 Kr87 2.18E-01 0

0.1524 0.1524 0.03 Kr88 2.18E-01 0

0.3774 03774 0.08 1(r89 1.419 0

0323 03230 0.46 KO9O 3.056 0

0.264 0.2640 0.81 Xel31m 1.64E-04 0

0.00149 0.0015 0.00 Xel33m 3.17E-04 0

0.00507 0.0051 0.00 Xe133 8.9SE-02 0

0.00577 0.0058 0.00 Xel35m 2.84E-01 0

0.07548 0.0755 0.02 Xe135 2.40E-01 0

0.04403 0.0440 0.01 Xe137 1.637 0

0.0303 0.0303 0.05 Xel3B 9.71E-01 0

0.199 0.1990 0.19 1131 11.88 32893 0.06734 11.5799 137.6 1132 113.4 381.1 0.4144 0.5478 62.1 1133 80.99 5846 0.10878 2.1549 174.5 1134 216.0 131.35 0.481 0.5270 113.8 1135 118.8 1228.4 0.3069 n0.736 87.5 I

Tot 57.2 To check these benchmarking results, the EAB X/Q of 1.694E-3 sec/n 3 from Reference 4 is multiplied by the sum of the normalized dose impact, 577.2 rem-m3 /sec. The result is 0.978 rem TEDE. The TEDE result from the VY CLB MSLB calculation (Reference 4) is 0.943 rem, 3.6%

less than the benchmark projection. This result is well within the variation of DCFs (the DCFs used for Reference 4 are not stated in the reference).

The EAB X/Q identified in the Design Input section is 1.7E-3 sec/m3, slightly different fiom the value used in Reference 4. The EAB dose for MSLB for this calculation is, therefore, increased from 0.978 rem TEDE to 0.981 rem TEDE to account for the slight increase in XIQ. This dose is well within the Reference 1 EAB TEDE limit of 2.5 rem.

PSAT 3019CF.QA.06 Pg 7 of 12 Rev 0 If the coolant activity release were 3.64 times the data from Reference 4, Item 2.13 which corresponds to the Tech Spec coolant activity limit for iodine of 1.1 pCi/gm; (i.e., if it corresponded, instead, to the short-term, 24-hour Tech Spec coolant activity limit for iodine of 4.0 psCi/gm), the EAB dose would be about 3.64 times greater or 3.57 rem TEDE. This approach conservatively applies the 3.64 factor to both the noble gas and the iodine contribution to dose.

Therefore, even using the short-term (24-hour) Tech Spec coolant activity (corresponding to a pre-existing iodine spike) and applying its impact conservatively, the FAB dose is well within the EAB TEDE limit of 25 rem for the pre-existing iodine spike. The conclusions reached for the EAB are conservative for the LPZ because of the greater distance to the Exclusion Area/LZ boundary than to the EAB, itself.

To apply Table 2 to the control room, the normalized dose impact has to be adjusted for the finite volume of the control room. Since the control room has no filtration protection, and since the exchange rate is high (assumed to be infinite, see Assumption 4), no other corrections are needed.

To make the finite volume adjustment, the finite volume dose correction factor is applied to the WB DCFs and Table 2 is recalculated as Table 3. The finite volume dose correction factor is from Reference I and is equal to V0 38/I 173 where V is the Control Room volume in ft3. Since the VY Control Room volume is 41,533.75 ft3, the correction factor is 0.031, and the corrected table for Control Room use is:

Table 3 -MSLB Activity Release and Normalized Dose Impact for Control Room Isotmpe Ci Released CEDE DCF WBDCF EffDCF Norm TEDE b lpact Kr83m 3.71E-02 0

4.62E-07 0.0000 0.00 KrS5m 6.66E-02 0

8.59E-04 0.0009 0.00 Kr85 2 18E-04 0

136E-05 0.0000 0.00 Kr87 2.ISE-01 0

4.72E-03 0.0047 0.00 IKrBS 218E-01 0

1.17E-02 0.0117 0.00 Kr89 1.419 0

L.OOE-02 0.0100 0.01 KM9O 3.056 0

8.18E-03 0.0082 0.02 Xcl3Im 1.64E-04 0

4.62E-05 0.0000 0.00 Xel33m 3.17E-04 0

LS7E-04 0.0002 0.00 Xel33 8.95E-02 0

1.79E-04 0.0002 0.00 Xcl35m 2.84E-01 0

234E-03 0.0023 0.00 Xe135 2.40E-01 0

1.36E-03 0.0014 0.00 Xe137 1.637 0

9.39E.04 0.0009 0.00 XM138 9.71E-01 0

6.17E-03 0.0062 0.01 1131 11.88 32893 2.09E-03 11.5146 136.8 1132 113.4 381.1 1.28E-02 0.1462 16.6 I133 80.99 5846 3.37EB03 2.0495 166.0 1134 216 131.35 1.49E-02 0.0609 13.1 1135 118.8 1228A 9.51E-03 0.4395 52.2 Total 384.8 To apply this result to the VY Control Room, one must only calculate the X/Q and multiply the normalized dose impact value of 384.8 rem TEDE-m3/sec by the X/Q value.

PSAT 3019CF.QA.06 Pg 8 of 12 Rev O ARCON96 X/O The release is assumed to occur in the Turbine Building (Reference 5, Item 8.9) and lasts only 6.8 seconds (Reference 5, Item 8.7). Therefore, it is unlikely that the Control Room dose will result from a slow release of activity from the Turbine Building following the very rapid release from the main steam piping. In fact, Reference 1 requires consideration of an immediate release to the environment. However, a quasi-steady plume release XIQ is available for Turbine Building releases, and it is used here as one case for the MSLB dose analysis (Case 1).

Using the 384.8 ren TEDE-m 3/sec and the Turbine Building ARCON96 X/Q of 4.68E-3 sec/n 3, the Control Room dose becomes 1.80 rem TEDE. This dose is well within the Control Room TEDE limit of 5.0 rem. If the coolant activity release were 3.64 times the data from Reference 4, Item 2.13 (which corresponds to the Tech Spec coolant activity limit for iodine of 1.1 pCi/gm; i.e., if it corresponded, instead, to the short-term, 24-hour Tech Spec coolant activity limit for iodine of 4.0 pCi/gm representing a pre-existing iodine spike), the Control Room dose would be

'about 3.64 times greater or 6.55 rem TEDE. While this value exceeds the Reference I Control Room dose limit of 5.0 rem TEDE, it is not considered a valid case because of the slow-release, plume X(Q which is inconsistent with the other, more appropriate release characteristics (i.e.,

instantaneous release to the environment). A more reasonable Control Room dose for MSLB is discussed in the next section.

Puff X/

The puff X/Q will be calculated next There are four steps to making this calculation: (1) evaluating the initial conditions of the steam release, (2) determining the volume and the diameter of the assumed hemispherical steam bubble, (3) evaluating the transit time for the bubble across the Control Room air intake and the associated XIOQ and (4) comparing this calculation to the NRC modeling described in Reference 3.

EvaluateInitial Conditions ofSteam Release. The liquid-steam mixture is assumed to be instantaneous per Assumption I even though the actual release time is 6.8 seconds. The MSLB has a steam release of 21,798 Ibm and a total (liquid+vapor) release of 59,500 Ibm. The net liquid release is then, 37,702 Ibm. The RCS pressure is 1045 psia. The temperature of the liquid-steam mixture at the time of the release to ambient is the saturation temperature corresponding to 1045 psia which is 5500F. Since the liquid is superheated at ambient pressure, some of this liquid will flash to steam. It is expected that the steam will form a 'bubble", and the unflashed liquid will settle by gravity. Logically, the bulk of the activity would remain with the liquid, but by Assumption 2, all of the activity is assumed to be released with the steam. This is a conservative assumption in this analysis.

Performing an energy balance to determine the flashing fraction, mh = mng + mih

PSAT 3019CF.QA.06 Pg 9 of 12 Rev 0 where m = initial liquid mass (Ibm) h = initial liquid enthalpy (Btullbm) mg = flashed steam mass (Ibm) hg = flashed steam enthalpy (Btullbm) mr= unflashed liquid mass (Ibm) hf = unflashed liquid enthalpy (Btu/lbm) and the unflashed liquid and flashed steam are at atmospheric pressure and saturation temperature corresponding to atmospheric pressure (212TF).

The flashing fraction, ff, is ff =m,(im = I(mh - mfhtahf/m Since Wm f=(m - m.)in = 1-iff we have ff= (h - (1 - ff)h)/bn

Thus, ff =(Ii-h-$(bg --hr(Ii-hr)hfg Using the steam tables, h = hA(550 F) - 549 Btulbm hf(212 F) = 180 Btu/bm hg(212 F) = 11 50 Bt/bm hrg(212 F) = 970 Btulbm
Thus, ff= (549-180)/970

= 0.38

PSAT 3019CF.QA.06 Pg 10 of 12 Rev 0 Thus, the mass of flashed steam (e.g. liquid that instantaneously flashes) is mg = 0.38 x 37,702 - 14,327 Ibm, and the total steam mass (i.e., initial bubble mass) is 21,798 + 14,327 = 36,125 Ibm.

The temperature of the mixture of released steam at 5500F and flashed steam at 2120F is Tb = (14,327 x 212 +21,798 x 55036,125 = 4160F = 876 R Determine the Volume and Diameter ofthe Assumed Hemispherical Steam Bubble. The initial volume of the bubble is V; = 36,125 Ibm/ps where p, = 0.0284 Ibm/ft3 (steam density at 876 R)

VI = initial volume of steam bubble (pure steam)

Thus, V = 1.272E6 ft3 = 3.6E4 m3 A spherical bubble of this volume has the radius

= 20.S A hemispherical bubble will have radius ra = 2r,!

where r, = radius of a sphere of equivalent volume. Thus, rh 1.26r,

= 25.83 m and the diameter is 51.7 m.

EvaluateBubble Transit Timeacross the ControlRoom AirIntae andAssociatedX/Q. The bubble transit time is based on a windspeed of 1.0 m/sec. The use of this value is explained in Appendix B. With a diameter of 51.7 m, the maximum bubble transit time across the control room air intake is 51.7 seconds at a windspeed of 1.0 m/sec.

As used in dose calculation models, the X/Q is the inverse of the dilution flow (units of m3/sec) provided by atmospheric mixing. In this case, (Case 2) there is no atmospheric mixing, rather, dilution is provided only by the flashing and expansion of the steam carrying the activity.

Therefore, one may assume that the release takes 6.8 seconds and that the "effective" dilution

PSAT 3019CF.QA.06 Pg 11 of 12 Rev 1 flow (in order to produce a dilution volume of 3.6E4 m3) is 5294 m3/sec over that 6.8 seconds.

The corresponding "effective" X/Q is 1/5294 = 1.89E-4 sec/m3. However, there is an additional correction that must be applied.

The total activity in the coolant is released over the same 6.8 seconds as the steam, but the release duration must be assumed to be 51.7 seconds (the transit time for the plume) at the 6.8 second release rate. This is because the puff does not pass by the Control Room air intake at same rate that it is released from the Turbine Building. Therefore, the effective X/Q is actually larger than 1.89E-4 sec/m3 by the ratio of the puff transit time divided by the release time; i.e.,

51.7/6.8 or 7.6. Increasing the 1.89E-4 sec/m by the factor of 7.6 gives the effective value of 1.44E-3 sec/m3.

Comparison to the NRC Modeling. In Appendix B, the NRC puff model is shown to produce a X/Q of 1.16E-3 sec/m3, about 1/5 less than the hemispherical model used in this section.

Therefore, this model is conservative with respect to NRC's model. It is also shown in Appendix B that any consideration of air entrainment (which the NRC model does to a limited degree) tends to lower the effective X/Q.

Control Room Dose Calculation with the PuffX/Q for Case 2. Using the 384.8 rem TEDE-m3/sec and the puff X/Q of 1.44E-3 sec/m3, the Control Room dose becomes 0.55 rem TEDE.

This dose is well within the Control Room TEDE limit of 5.0 rem. If the coolant activity release were 3.64 times the data from Reference 4, Item 2.13 (which corresponds to the Tech Spec coolant activity limit for iodine of 1.1 pCi/gm; i.e., if it corresponded, instead, to the short-term, 24-hour Tech Spec coolant activity limit for iodine of 4.0 pCi/gm), the Control Room dose would be about 3.64 times greater or 2.00 rem TEDE. This dose is also well within the Control Room TEDE limit of 5.0 rem.

Results Two MSLB cases are analyzed. In Case 1, the X/Q is based on ARCON96. In Case 2, the X/Q is based on a puff release assumed to be hemispherical in shape, of uniform concentration, and not subject to dilution by air entrainment. In Appendix B this model is compared to an NRC model and is shown to be moderately conservative.

In both cases the results are based on an instantaneous release fully consistent with Reference 1.

The activity release is based on the Tech Spec coolant activity limit for continuous operation.

The Case 1 results are EAB = 0.981 rem TEDE (conservative for the LPZ) and Control Room =

1.80 rem TEDE.

The Case 2 results are EAB = 0.981 rem TEDE (conservative for the LPZ) and Control Room =

0.55 rem TEDE.

PSAT 3019CF.QA.06 Pg 12 of 12 Rev 0 Additional results were generated for an activt release based on the Tech Spec coolant activity limit for operation of not more tann 24 consecutive hours. This activity level corresponds to a pre-existing iodine spike.

The Case 1 results are EAB = 3.57 rem TEDE (conservative for the LPZ) and Control Room = 6.55 rem TEDE.

The Case 2 results are EAB = 3.57 rem TEDE (conservative for the LPZ) and Control Room = 2.00 rem TEDE.

Conclusions The MSLB doses are well within their Reference 1 limits except that the Control Room dose exceeds its limit slightly ifAboh (1) a continuous release XIQ is used (and such a XIQ is not required by Reference 1) and (2) if the coolant activity is 3.64 times greater than the continuous operation Tech Spec limiting value of 1.1 pCi/grm DE 1131 (i.e., if it is equal to the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> maximum Tech Spec value of 4.0 LCigSm DE 1131).

PSAT 3019CF.QA.05 Page Al of 3 Rev 0 Appendix A - Determination of Whole Body DCF for Kr9O Kr9O is a short-lived noble gas tiat has essentially no effect on radiation dose for any accident involving a time-dependent release. It is not included in the dose conversion factor library for RADTRAD (Reference A-i). For the MSLB accident where the release to the environment is assumed to be instantaneous, the current analysis (Reference A-2) includes Kr9O. The dose conversion factor can be readily detelmined from the average gamma energy using the expression from Reference A-3 (0.25 x the average photon energy in MeV to obtain the whole body DCF in rem-m3/Ci-sec).

The following Table A-I (based on Reference A-4) shows the photon energy distribution for ganma radiation from Kr90 decay. The average gamma energyis 1055 KeY per disintegration with that value being calculated as shown in the table. Columns A and B are data from Reference A-4 as well as the conversion factor for obtaining Column C from Columns A and B (i.e., multiplying the Relative Intensity by 0.038 to obtain the Absolute Intensity in MeV per 100 disintegrations, and then dividing by 100 and by the energies of the individual photons in each row to obtain the number of photons per disintegration for each photon energy). From Column C, Column D is a straightforward multiplication of C x A, and the average energy per disintegration is the sum of Column D.

The DCF is 0.025 times 1.055 MeV or 0.264 rem-m3/Ci-sec.

Table A Relative Intensity of Gamma Radiation for Kr9O A. Photon Encrgy B. Relativ C. Photons/Dis D. MeMdis by cnmrgy KeV Intensity (B*0.038/100/ AJ10M)

(CxA) 539.5 17.3 1.22E-02 6.571303 578.06 15.9 1.05E102 6.04E103 655.17 202 1.17E-01 7.68E-02 707.05 1000 5.37E-01 3.80EO01 740.82 75 3.8Ei-02 2.85E-02 786.02 42 2.03E102 1.60E-02 840.29 25 1.13E-02 9.50S-03 91338 6.8 2.83E-03 2.58E-03 939.9 11.2 4.53E-03 4.26E.03 955.84 58 2.31E.02 2.20E-02 1123.37 13.1 4.43E-03 4.98E-03 1133.5 4.9 1.64E-03 1.86E-03 1233.21 110 3.39E.02 4.18E-02 1323.57 21 6.03E-03 7.98E-03 1344.76 13.5 3.811303 5.13ED03 1362.32 295 8.23E.02 1.12E101 1396.16 25 6.80E-03 9.OE-F03 1418.34 21 5.63E103 7.98EM03 1440.21 8.5 2.24E-03 3.23E-03 1465.9 9.6 2A9E-03 3.65E.03 1486 14.7 3.76E-03 5.59E103

PSAT 3019CF.QA.05 PageA2 of 3 Rey0 1542.2 35 8.62E-03 1.33E-02 1610.8 59 1.39E-02 2.24E-02 1625.11 44 1.03E-02 1.67E-02 1828.9 10.7 2.22E-03 4.07E.03 1836.49 38 7.86E-03 1.44E-02 1888.79 14.7 2.96E4-3 5-59E-03 2002.9 6.7 L27E-03 2.SSE-03 2024.1 11.6 2.18E-03 4.41E-03 2040.79 21 3.91E-03 7.98E.03 2073 4

7.33E-04 1.52E-03 2105.7 15 2.71E-03 S.70E.03 2121.2 9.8 1.76E-03 3.72E-03 2172.9 3.4 5.95E-04 1.29E-03 2297.1 7.4 1.22E03 2.81E-03 2318.6 28 4.59E-03 1.06E-02 2411.8 11.4 1.80E-03 4.33E-03 2433.09 26 4.06E03 9.88E-03 2543.93 7.7 1.15E-03 2.93E-03 2612.2 14.6 2.12E-03 5.55E-03 266SA 8.9 1.27E-03 3.38E-03 2682.6 12.2 1.73E-03 4.64E-03 2730.5 44 6.12E-03 1.67E-02 2763.9 5

6.87E-04 l90E-03 2801 9.1 1.23E-03 3A6E-03 2864.1 31 4.11E-03 1.ISM02 2987.1 29 3.69E-03 1.MOE-02 3022.3 6.2 7.80E-04 2.36E-03 3116.7 9.9 1.21E-03 3.76E-03 3231.3 89

.05E-02 3.38E02 3318.5 31 3.55B-03 1.L1SE02 3505.8 6.5 7.05E-04 2.47E-03 3669.1 7.3 7.56E-04 2.77E-03 3949 9.4 9.OSE-04 3n57E.03 3955 8.4 8.07E-04 3.19E-03 4023.1 6.7 6.33E-04 2.55E-03 4290.9 17 1.51E-03 6.46E-03 4297.2 16.7 I.48E-03 6.35E-03 4320.9 9.1 8.OOE-04 3A.46E03 4367.3 16.1 IAOE-03 6.12E-03 4372.8 14.1 1.23E-03 5.36E-03 4495.1 8.8 7.44E-04 3.34E-03 4762.3 6.8 5.43E-04 2.58E-03 4787.4 5.7 4.52E-04 2.17E.03 5154 2.8 2.06E-04 1.06E-03 5221.6 7.9 5.75E-04 3.0EB-03 MeV/dis 1.055E+00

PSAT 3019CF.QA.05 PageA3 of 3 Rev 0 References A-1 S. L Humphries et al, 'RADTRAD: A Simplified Model for Radionuclide Tansport and Removal and Dose Estimtion", NUREGICR-6604, Sandia National Laboratories, December 1997 A-2 VY Calculation VYC-2064, "VY - Radiological Evaluation of a Main Steam Line Break Accident under Hot Standby Conditions", Revision 0 A-3 U.S. NRC, 'Assumptions Used for Evaluating the Potential Radiological Consequences of a Loss of Coolant Accident for Boiling Water Reactors," Regulatory Guide 1.3, Rev. 2, June, 1974 A-4 Evaluated Nuclear Structure Data File (ENSDF),

http://www nndc.bnl.gov/nndc/ensdf7ensdfindex.htmI. Brookhaven National Laboratory, May 14,2003 C.

PSAT 3019CF.QA.05 PageBi of 3 Rev O Appendix B - Comparison of the Calculated Puff X/Q to Preliminary NRC Methods In Reference B-i, the NRC presents a model for a puff X/Q. The model has the following features:

1. The puff is released at ground-level as is assumed to pass the control room air intake at the maximum puff dimension.
2. It is a spherical puff.
3. The puff is allowed to entrain air and to expand slightly as it moves downwind.
4. Activity within the puff is normally distributed, and the integration of the puff activity concentration as it crosses the control room air intake must be from -3a to +3a (unless the release point is closer than 3a to the control room air intake in which case the integration begins at x).

This can be compared to the hemispherical model described in the main body of the calculation as follows (point by point):

1. Same.
2. Hemispherical rather than spherical with a nominal diameter 1.26 times greater than the NRC spherical puff However, for the NRC model, 3a = (3.429 x Volume)t 3 instead of n = (OA78 x Volume)"13; and this means that the integration time is 1.93 times greater for the NRC model dispite the greater diameter of the hemisphere (relative to that of a sphere) in the model presented in the main body of the calculation.

Helping to counteract this effect is the fact that the effective volume for the NRC puff is 14.35 times greater (i.e., 2 x 3.429/0.478), so the average concentration is 14.35 times less for the NRC model than for the model presented in the main body of the calculation.

However since the maximum radial and maximum cross-wind concentration is used in the NRC model (i.e., the integration is done as the center of the puff moves across the air intake), the benefit of the distributed concentration is limited, since the peak concentration in the cross-wind and vertical directions will be 2.39 times greater than the average (ie.', 6/(21n)1fl. This means that the benefit of the greater effective volume of the NRC model is reduced from the value of 14.35 to a value of (14.35/2.392) = 2.51. Then, taking into consideration the longer integration time (NRC model 1.93 times greater), the net benefit of the NRC model is reduced to 2.5111.93 = 1.3.

3. No air entrainment. Air entrainment provides dilution, but it also increases the diameter of the puff and, therefore, the integration time at whatever windspeed is assumed.

However, a volume of air assumed to be entrained in the puff decreases the concentration

PSAT 3019CF.QA.05 Page B2 of 3 Rev 0 linearly while it increases the diameter (and, therefore, the integration time) by the cube root of the volume. Ignoring air entrainment is, therefore, conservative.

To evaluate the degree of conseratism introduced by ignoring air entrainment in the model presented in the main body of the calculation, one must know the distance traversed by the NRC's puff before the control room air intake is encountered (the uniform concentration model in the main body of the calculation does not require that information). If one assumes that the distance traversed is 33 meters for the center of the puff (the distance assumed in the ARCON96 modeling - see Reference B-2) and then refers to Figure 3 of Reference B-I assuming Stability Class F (as suggested by Reference B-I), the one-sigma puff expansion in the down-wind and cross-wind direction is about 1.7 m. It is assumed to be zero in the vertical direction The spherical radius of the initial puff (3cs before expansion) would be 2A3 times that calculated in the main body of the calculation for the nominal sphere; i.e., 49.8 m.

Increasing this radius by 2 x 1.7 m in both the down-wind and cross-wind directions only increases the effective volume by about a factor of 1.14. However, it also increases the diameter by a factor of 1.07 (and the associated integration time). Therefore, the net benefit of expansion due to entrainment in the NRC model is about a factor of 1.07.

4. Uniform concentration assumed, and therefore, no activity excluded from the integration.

For the NRC model, integration from -3c to +3t; creates essentially the same degree of completeness.

It is clear that the model described in the main body of the calculation is the same or conservative on all points.

The overall conservatism of the hemispherical, uniform concentration model in the main body of the calculation is 1.3 for the assumed hemispherical vs. spherical configuration (and uniform vs.

distributed concentration), and 1.07 for the constant volume (no air entrainment). Multiplying these contributions, the overall conservatism is 1.39. Since the X/Q developed for the model presented in the main body of the calculation is 1.44E-3 sec/n 3, the NRC model would be expected to give a result of 1.04E-3 sec/n. This can be checked by actually calculating the NRC result (assuming a -3a to +3u integration).

In Referece B-l, Section 5, the guidance is to use F-Stability and a windspeed of 1.0 m/sec.

Therefore, these are the values that are appropriate for use in the main body of the calculation.

However, stability does not enter into the hemispherical, uniform concentration model because air entrainment is not considered; and thus, only the windspeed of 1.0 mrsec (based on References B-1 and B-3) is actually used.

The integration may be carried out on a spreadsheet assuming the expression for a, is 0.08x° 875 (based on a fit of the Reference B-I figure between x = 10 and 100 m). The result is a X/Q of 1.16E-3 secin 3, about 11% greater than the estimate of 1.04E-3 sec/n 3 given above. The value in the main body of the calculation is still bounding

PSAT 3019CF.QA.05 Page B3 of 3 Rev 0 References B-1 "Atmospheric Relative Concentrations for Control Room Radiological Habitability Assessments at Nuclear Power Plants", US NRC Regulatory Guide 1.194, Revision 0, June 2003 B-2 VY Calculation VYC-1967, "Control Room Atmospheric Dispersion Factors fbr Releases via the Turbine Buildinge' RO B-3 U.S. NRC, "Assumptions Used for Evaluating the Potential Radiological Consequences of a Loss of Coolant Accident for Boiling Water Reactors," Regulatory Guide 1.3, Rev. 2, June, 1974