LIMITING CONDITION FOR OPERATION SURVEILLANCE REQUIREMENTS 3.6 PRIMARY SYSTEM BOUNDARY (Cont) 4.6 PRIMARY SYSTEM BOUNDARY (Cont)
B. Coolant Chemistry
- 1. The reactor coolant system radioactivity concentration In water shall not exceed 20 microcuries of total iodine per ml of water.
B.
Coolant Chemistry
- 1. a. A reactor coolant sample shall be taken at least every 96 hours0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br /> and analyzed for radioactivity content.
- b. Isotopic analysis of a reactor coolant sample shall be made at least once per month.
l
- 2. If Specification 3.6.B cannot be met, an orderly shutdown shall be initiated and the reactor shall be in Hot Shutdown within 24 hrs. and Cold Shutdown within the next 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.
Amendment No. 14, 139, 104 202 3/4.6-3
This page is intentionally left blank.
Revision 4A:,
202 B3/4.6-4
BASES:
3/4.6 PRIMARY SYSTEM BOUNDARY (Cont)
B.
Coolant Chemistr (Cont)
The Iodine radioactivity will be monitored by reactor water sample analysis. The total iodine activity would not be expected to change over a period of 96 hours0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br />. In addition, the trend of the stack off-gas release rate, which is continuously monitored, is an indication of the trend of the iodine activity In the reactor coolant. Since the concentration of radioactivity in the reactor coolant is not continuously measured, coolant sampling would be ineffective as a means to rapidly detect gross fuel element failures. However, some capability to detect gross fuel element failures is inherent in the radiation monitors in the off-gas system and on the main steam lines.