ML031700389

From kanterella
Jump to navigation Jump to search
Byron/Braidwood, Relief Request - Repair for the CRDM Canopy Seal Weld
ML031700389
Person / Time
Site: Byron, Braidwood  
(NPF-037, NPF-066, NPF-072, NPF-077)
Issue date: 06/18/2003
From: Mahesh Chawla
NRC/NRR/DLPM/LPD3
To: Bauer J
Exelon Corp
Chawla M, NRR/DLPM, 415-8371
References
Download: ML031700389 (2)


Text

From:

Mahesh Chawla To:

Joseph.bauer@exeloncorp.com Date:

6/18/03 5:07PM

Subject:

Relief Request - Repair for the CRDM Canopy Seal Weld - Byron/Braidwood Following is the list of questions we would like to discuss with you on the subject relief request.

Please let me know your availability to this telephone conversation. If you have any further questions, please give me a call.

The submittal states that a post-maintenance pressure test (VT-2) at nominal temperature and pressure will be performed.

1. Explain how this will be accomplished with the DRPI stacks in place, providing a sketch if necessary.
2. The submittal does not include information on how long the system test will be performed at pressure. Explain the planned procedure for conducting the system pressure test. Discuss which provisions of the ASME Code will be applied for the pressure test.
3. If cracking is found, there may be boric acid residue on the area surrounding the canopy seal welds. Explain plans for cleaning the area around the canopy seal welds if boric acid residue is found.

CC: George Dick Mail Envelope Properties (3EF0D496.CBA : 15 : 21352)

Subject:

Relief Request - Repair for the CRDM Canopy Seal Weld -

Byron/Braidwood Creation Date:

6/18/03 5:07PM From:

Mahesh Chawla Created By:

MLC@nrc.gov Recipients Action Date & Time exeloncorp.com Transferred 06/18/03 05:07PM Joseph.bauer (Joseph.bauer@exeloncorp.com nrc.gov owf4_po.OWFN_DO Delivered 06/18/03 05:07PM GFD CC (George Dick)

Post Office Delivered Route exeloncorp.com owf4_po.OWFN_DO 06/18/03 05:07PM nrc.gov

Files Size Date & Time MESSAGE 1675 06/18/03 05:07PM Options Auto Delete:

No Expiration Date:

None Notify Recipients:

Yes Priority:

Standard Reply Requested:

No Return Notification:

None Concealed

Subject:

No Security:

Standard To Be Delivered:

Immediate Status Tracking:

Delivered & Opened