Category:Deficiency Report (per 10CFR50.55e and Part 21)
MONTHYEARML19317D0932019-10-25025 October 2019 Engine Systems, Inc., 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10 CFR21-0127, Rev. 0, Emd Fuel Injectors - Seized Plunger and Bushing ML17194A8252017-07-11011 July 2017 Part 21 Report Re Wedge Pin Failure in Anchor Darling Motor Operated Double Disc Gate Valves with Threaded Stem to Upper Wedge Connections ML17179A3782017-06-0707 June 2017 TE Connectivity - Part 21 Transfer of Information TE-023 ML16294A2642016-10-18018 October 2016 Part 21 Report - Defective Current to Pressure Transducers ML15050A2492015-02-0505 February 2015 Revision to 10 CFR Part 21 Final Notification for Event 50015 for GE CR120 Relays ML14275A1622014-09-25025 September 2014 Notification of Potential Part 21 Report - Electromatic Relief Valve Excessive Wear ML14210A0102014-07-23023 July 2014 Part 21 - Unseating of Valve Spring on Scram Solenoid Pilot Valve ML14204A7082014-07-23023 July 2014 Enclosure 2, Description of Closure Evaluation, Non-Proprietary Information - Class I (Public) ML14204A7072014-07-23023 July 2014 Completed Evaluation of Part 21 Potentially Reportable Condition Notification: Unseating of Valve Spring on SSPV ML14072A3262014-03-13013 March 2014 Enclosure 2: Description of Evaluation ML14072A3282014-03-13013 March 2014 Part 21 60-Day Interim Report Notification Re Unseating of Valve Spring on SSPV ML13165A3422013-06-12012 June 2013 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers ML13064A0122013-02-25025 February 2013 Notification of Potential Part 21 Report Re Wedge Pin Failure of an Anchor/Darling Double-Disc Gate Valve ML13042A0962013-02-0808 February 2013 Completed Evaluation of Part 21 Potentially Reportable Condition Notification: Error in Main Steam Line High Flow Calculational Methodology ML13044A0752013-02-0808 February 2013 Part 21 - Completed Evaluation for Potential Error in Main Steam Line High Flow Calculational Methodology ML12352A1232012-12-13013 December 2012 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers ML12348A1362012-12-13013 December 2012 Part 21 60-Day Interim Report Notification: Adequacy of Design Change in Am Magne-Blast Circuit Breakers ML12347A3082012-12-12012 December 2012 Part 21 60-Day Interim Report Notification: Error in Main Steam Line High Flow Calculational Methodology ML12319A0122012-09-27027 September 2012 Error in Main Steam Line High Flow Calculational Methodology ML12163A1302012-06-0606 June 2012 Part 21 Report - Failure of CRD Collet Retainer Tube/Outer Tube Weld ML12158A4472012-06-0606 June 2012 Part 21 60-Day Interim Report Notification - Closufailure of CRD Collet Retainer Tube/Outer Tube Weld ML12040A2832012-02-0707 February 2012 Notification of Potential Part 21 - Failure to Include Seismic Input in Reactor Control Blade Customer Guidance ML12038A0282012-02-0202 February 2012 Failure of CRD Collet Retainer Tube/Outer Tube Weld ML12032A2402012-02-0101 February 2012 Notification of Potential Part 21 - 60-Day Interim Report Notification: Failure of CRD Collet Retainer Tube/Outer Tube Weld ML11228A0842011-08-12012 August 2011 Notification of Part 21 - Failure to Include Seismic Input in Reactor Control Blade Customer Guidance ML1122401422011-08-11011 August 2011 Part 21 60-Day Interim Report Notification: Failure to Include Seismic Input in Channel-Control Blade Interference Customer Guidance ML1104800542011-02-15015 February 2011 Notification of Potential Part 21 Reportable Condition: Crack Indications in Marathon Control Rod Blades ML1104604872011-02-15015 February 2011 Notification of Potential Part 21 Reportable Condition Re Design Life of D and s Lattice Marathon Control Blades ML1035100312010-12-15015 December 2010 Notification of Potential Part 21 Report Concerning Failure to Include Seismic Input in Reactor Control Blade Customer Guidance ML1035001742010-12-15015 December 2010 Notification of Potential Part 21 Re 60-Day Interim Report Notification: Failure to Include Seismic Input in Channel-Control Blade Interference Customer Guidance ML1029502812010-10-20020 October 2010 Part 21 Notification - Crack Indications in Marathon Control Rod Blades ML1029305052010-10-20020 October 2010 GE Hitachi Nuclear Energy - Notification of Potential Part 21 60-Day Interim Report: Crack Indications in Marathon Control Rod Blades ML1027300632010-09-27027 September 2010 Notification of Potential Part 21 Report Concerning Failure to Include Seismic Input in Reactor Control Blade Customer Guidance ML1027006142010-09-27027 September 2010 Part 21 60-Day Interim Report Notification: Failure to Include Seismic Input in Channel-Control Blade Interference Customer Guidance ML1025202192010-09-0303 September 2010 Part 21 - Failure to Include Seismic Input in Reactor Control Blade Customer Guidance ML0930603952009-10-30030 October 2009 Transnuclear, Inc. - Submittal of Thirty Day Written Report of a Potential Deviation and Failure to Comply Associated with Unsubstantiated Certified Materials Test Reports for Certain Small Parts Utilized in Products Fabricated ML0927805882009-10-0101 October 2009 Transnuclear, Inc Part 21 Report Re Fasteners on Spent Fuel Storage Devices Not Meeting Standards ML0833301872008-11-21021 November 2008 Notification of Potential Part 21 Re Tyco Electronics, Transfer of Information - CII-012 ML0831900172008-11-12012 November 2008 Notification of Potential Part 21 on All Dimensionally Verified Commercial Grade Items Processed Per Fisher Manufacture Procedure Fmp 2K28 ML0823901062008-08-25025 August 2008 Notification of Potential Part 21 on Failure of F and G Switches ML0812008822008-04-14014 April 2008 Notification of Potential Part 21 on Safety Related Noncompliance Deviation ML0809906342008-04-0404 April 2008 Part 21 Notification Regarding Failure to Comply with the Requirements for Dedication of Commercial Grade Items ML0734402112007-12-0707 December 2007 Deficiency Report Part 21 Potential Insufficient Thread Engagement for Certain Pressure Transmitters ML0706802882007-03-0707 March 2007 Notification of Potential Part 21 on Defect in E7000 Relays ML0609504012006-04-0303 April 2006 Director Office of Inspection & Enforcement Reference: 10 CFR 21 Notification of 3/30/06 Rev1 ML0603303452006-01-23023 January 2006 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10CFR21-0091, Rev. 0., Woodward DRU Controls (Manufactured Between November 2000 and November 2005) ML0526900842005-09-20020 September 2005 Part 21 Notification Completion: Critical Power Determination for GE14 and GE12 Fuel with Zircaloy Spacers ML0509504282005-03-29029 March 2005 10CFR21 Reportable Condition Notification: Involving Potential to Exceed Low Pressure Technical Specification Safety Limit ML0316903862003-06-11011 June 2003 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc., Report No. 10CFR21-0087, Rev 0, Emd Electric Start Motors at Oyster Creek 2019-10-25
[Table view] |
Text
XJj~J1 ENGINE SYSTEMS, INC.
J 1220 S. Washingtn St., Rocky Mount, NC 27801 Telephone: 252/977-2720
_, - P.O. Box 1928, Rocky Mount, NC 27802-1928 Fax: 252/446-1134 June 11, 2003 U.S. Nuclear Regulator Commission Document Control Desk Mail Stop OPI-17 Washington, DC 20555
Subject:
I OCFR21 Reporting of Defects and Non-Compliance -
Engine Systems, Inc. Report No. 10CFR21-0087, Rev. 0 EMD Electric Start Motors at Oyster Creek
Dear Sir:
The enclosed report addresses a reportable notification about EMD electnc start motors at Oyster Creek (manufactured in 1999) - P/N 10478830.
A copy of the report has also been sent to the NRC.
Please sign below, acknowledging receipt of this report, and return a copy to the attention of Document Control at the address above (or, fax to number 252/446-1134) within 10 working days after receipt.
Yours very truly, ENGINE SYSTEMS, INC.
Susan Woolard Document Control Please let us know if ANY of your mailing Information changes - name of recipient, name of company/facility, address, etc. Mark the changes on this acknowledgment form and send to us by mall or FAX to the number above.
RECEIVED:
(93)
DATE:
Quality Performance With Pride
( ENGINE SYSTEMS INI 1220 S. Washington St. Rocky Mount, NC 270 01 Telephone: 2521977-2720 P.O. Box 1928, Rocky Mount, NC 27802-1928 Fax: 2521446-1134 Report No. IOCFR21-0087 Rev. 0: 06/11/03 IOCFR21 REPORTING OF DEFECTS AND NON-COMPLIANCE COMPONENT: EMD Electric Start Motors at Oyster Creek (manufactured in 1999).
P/N 10478830 SYSTEM: EMD diesel generators at Oyster Creek CONCLUSION: Reportable in accordance with 10CFR21.
Prepared By: Date: 6_/___
/ Engineering Manager Reviewed By: Date:
Quality Assdrance Manager Quality Performance With Pride
Report No. 10CFR21-0087 Record of Revisions Page: 1 of 1 REV DATE PAGE DESCRIPTION
Report No. IOCFR21-0087 Revision: 0 Date: 06/11/03 Page: 1 of 4 COMPONENT:
EMD electric start motors, P/N 10478830 manufactured in 1999.
SUMMARY
Engine Systems Inc. (ESI) has concluded an investigation of a condition reported with an EMD electric start motor. Oyster Creek Generating Station purchased 4 electric start motors from ESI on their PO 0744183 in 1999. One of these starters, p/n 10478830, s/n 05D99 was retumed to ESI for failure analysis. Reportedly the starter, having been in the site's inventory since receipt, was bench tested and the starter drive or "Bendix" did not extend properly from rest upon application of voltage to the solenoid. ESI performed functional testing and inspection of the starter. Inspection revealed that the starter drive brake washer had adhesive applied to both sides (normally, only one side has adhesive). This caused the brake washer and starter drive to astick" to the lever housing; thus preventing the starter drive from operating properly.
DISCUSSION:
Upon removal of the Bendix assembly from the starter, a white opaque ring of material was found adhered to the lever housing. This material was in a position such that the Bendix assembly would rest against it in the de-energized state.
Internal view of lever housing, Bendix removed
Report No. 10CFR21-0087 Revision: 0 Date: 06111/03 Page: 2 of 4 White material removed from lever housing Non-drive end of Bendix assembly, brake washer surface
I G;-M (DOD 0 n (30 eEMC =3cm 0 o w
to <o (D - j O CA 0 C -
0)0
~ C) a:,
Co 4
Report No. 10CFR21-0087 Revision: 0 Date: 06111/03 Page: 4 of 4 The function of the brake washer is to slow down the starter's armature after the engine starts and the pinion disengages. This reduces the starter's coast down time and conserves brush life.
ESI contacted the manufacturer, Delco Remy, to discuss the findings. The representative reviewed photos of the material found and determined it was an RTV adhesive formerly used to adhere the brake washer. Delco Remy's practice is to either adhere the brake washer to the lever housing or to the Bendix assembly. In the early 1980's, RTV was used exclusively to adhere the brake washer. In 1986, their sub-supplier applied a mastic type adhesive on the brake washer.
Sometimes the pre-applied adhesive did not provide sufficient bond strength, so RTV was used occasionally as a supplemental adhesive. At some point in 1999, the manufacturer stated that they had a process problem in which the brake washer was installed in the standard manner, but RTV was applied to the opposite side also. Delco Remy could not confirm the exact dates of this problem, but they estimate that it occurred only over a 2 week period. In April, 2001 a stronger adhesive was applied by the brake washer sub-supplier and the use of RTV was eliminated.
Because the process problem date could not be obtained from the manufacturer, all starters with 1999 serial numbers are considered suspect.
CONCLUSION:
Improper operation of the starter's drive assembly was caused by the presence of silicone RTV adhesive on the face of the lever housing. In this starter assembly, the brake washer was apparently adhered to the Bendix assembly using the pre-applied adhesive while RTV was applied to the lever housing and/or to the opposite face of the brake washer. The RTV surface maintained a sticky finish relative to the face of the brake washer, and this led to higher than normal required forces to separate the two. Therefore, with normal test voltage applied to the starter's solenoid, the Bendix would not engage.
After removal of the improperly applied RTV, the Bendix assembly operated properly.
CUSTOMERS AFFECTED:
ESI has searched its historical data and has determined that only one (1) customer is affected.
All other EMD users have air start motors.
CUSTOMER SITE PIN SIN or Date Code ESI ORDER I GPU Oyster Creek Nuclear Station 10478830 99 05D99 61790 l Note: One of "05D99" starters has already been corrected by ESI as part of the failure analysis.
CORRECTIVE ACTION:
- 1. Inspect starters with serial numbers containing "99" for a "sticking" starter drive. Two (2) starting motors are required for the engine. The solenoids of each motor are connected in series; therefore, the starter drive must engage at % of the minimum system voltage.
- 2. Starters with sticking drives should be disassembled and the RTV removed; or, returned to ESI for evaluation and repair.