June 20, 2003 Mr. Roy A. Anderson President & Chief Nuclear Officer PSEG Nuclear, LLC - X04 Post Office Box 236 Hancocks Bridge, NJ 08038

SUBJECT:

SALEM NUCLEAR GENERATING STATION, UNIT NOS. 1 AND 2 -

RE: CHANGES AND CORRECTIONS TO TECHNICAL SPECIFICATIONS BASES PAGES (TAC NOS. MB7539 AND MB7540)

Dear Mr. Anderson:

By letter dated January 24, 2003, PSEG Nuclear, LLC (PSEG) provided changes to five Technical Specification (TS) Bases pages for the Salem Nuclear Generating Station (Salem),

Unit Nos. 1 and 2. The U.S. Nuclear Regulatory Commission (NRC) staff has no objection to these changes.

Also, by letter dated March 20, 2003, PSEG identified six additional TS Bases pages that, in this case, needed correction. These pages were submitted on June 28, 2002, as part of an amendment request changing fuel decay time requirements. Due to an oversight, when new information was added to the six TS Bases pages, existing information was inadvertently removed from the revised pages issued with Amendment Nos. 251 (Salem, Unit No. 1) and 232 (Salem, Unit No. 2) on October 10, 2002. As a result, corrected TS Bases pages needed to be reissued.

The enclosed TS Bases pages are being distributed for inclusion in their respective TSs. If you have any questions, please contact me at (301) 415-1324.

Sincerely,

/RA/

Robert J. Fretz, Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-272 and 50-311

Enclosure:

Revised TS Bases Pages cc w/encls: See next page

June 20, 2003 Mr. Roy A. Anderson President & Chief Nuclear Officer PSEG Nuclear, LLC - X04 Post Office Box 236 Hancocks Bridge, NJ 08038

SUBJECT:

SALEM NUCLEAR GENERATING STATION, UNIT NOS. 1 AND 2 -

RE: CHANGES AND CORRECTIONS TO TECHNICAL SPECIFICATIONS BASES PAGES (TAC NOS. MB7539 AND MB7540)

Dear Mr. Anderson:

By letter dated January 24, 2003, PSEG Nuclear, LLC (PSEG) provided changes to five Technical Specification (TS) Bases pages for the Salem Nuclear Generating Station (Salem),

Unit Nos. 1 and 2. The U.S. Nuclear Regulatory Commission (NRC) staff has no objection to these changes.

Also, by letter dated March 20, 2003, PSEG identified six additional TS Bases pages that, in this case, needed correction. These pages were submitted on June 28, 2002, as part of an amendment request changing fuel decay time requirements. Due to an oversight, when new information was added to the six TS Bases pages, existing information was inadvertently removed from the revised pages issued with Amendment Nos. 251 (Salem, Unit No. 1) and 232 (Salem, Unit No. 2) on October 10, 2002. As a result, corrected TS Bases pages needed to be reissued.

The enclosed TS Bases pages are being distributed for inclusion in their respective TSs. If you have any questions, please contact me at (301) 415-1324.

Sincerely,

/RA/

Robert J. Fretz, Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-272 and 50-311

Enclosure:

Revised TS Bases Pages cc w/encls: See next page DISTRIBUTION:

PUBLIC CHolden WBeckner GMeyer, RGN-I PDI-2 R/F JClifford CRaynor OGC ACRS RFretz GHill (2)

ADAMS ACCESSION NO: ML031640124 OFFICE PDI-2/PM PDI-2/LA PDI-2/SC NAME RFretz CRaynor JClifford DATE 6/16/03 6/17/03 6/19/03 OFFICIAL RECORD COPY

PSEG Nuclear LLC Salem Nuclear Generating Station, Unit Nos. 1 and 2 cc:

Mr. Timothy J. OConnor Vice President - Operations PSEG Nuclear - X15 P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. John T. Carlin Vice President - Engineering PSEG Nuclear - N10 P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. David F. Garchow Vice President - Projects and Licensing PSEG Nuclear - N28 P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. Gabor Salamon Manager - Nuclear Safety and Licensing PSEG Nuclear - N21 P.O. Box 236 Hancocks Bridge, NJ 08038 Jeffrie J. Keenan, Esquire PSEG Nuclear - N21 P.O. Box 236 Hancocks Bridge, NJ 08038 Ms. R. A. Kankus Joint Owner Affairs PECO Energy Company Nuclear Group Headquarters KSA1-E 200 Exelon Way Kennett Square, PA 19348 Lower Alloways Creek Township c/o Mary O. Henderson, Clerk Municipal Building, P.O. Box 157 Hancocks Bridge, NJ 08038 Dr. Jill Lipoti, Asst. Director Radiation Protection Programs NJ Department of Environmental Protection and Energy CN 415 Trenton, NJ 08625-0415 Brian Beam Board of Public Utilities 2 Gateway Center, Tenth Floor Newark, NJ 07102 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Senior Resident Inspector Salem Nuclear Generating Station U.S. Nuclear Regulatory Commission Drawer 0509 Hancocks Bridge, NJ 08038

LIST OF REVISED AND CORRECTED TECHNICAL SPECIFICATION BASES PAGES FACILITY OPERATING LICENSE NO. DPR-70 DOCKET NO. 50-272 Replace the following pages of the Appendix A, Technical Specifications (TSs), with the attached revised pages.

Remove Insert B 3/4 6-4 B 3/4 6-4 B 3/4 7-3 B 3/4 7-3 Replace the following pages of TSs, Appendix A, with the attached corrected pages.

Remove Insert B 3/4 9-1 B 3/4 9-1 B 3/4 9-2 B 3/4 9-2 B 3/4 9-3 B 3/4 9-3 Enclosure

LIST OF REVISED AND CORRECTED TECHNICAL SPECIFICATION BASES PAGES FACILITY OPERATING LICENSE NO. DPR-75 DOCKET NO. 50-311 Replace the following pages of the Appendix A, Technical Specifications (TSs), with the attached revised pages.

Remove Insert B 3/4 6-3 B 3/4 6-3 B 3/4 6-4 B 3/4 6-4 B 3/4 7-3 B 3/4 7-3 Replace the following pages of TSs, Appendix A, with the attached corrected pages.

Remove Insert B 3/4 9-1 B 3/4 9-1 B 3/4 9-2 B 3/4 9-2 B 3/4 9-3 B 3/4 9-3