Page 1 Thomas Alexion - FOLLOW-UP RAI ON POWER UPRATE STARTUP TESTING REPORT From:
Thomas Alexion To:
RSCHEID@ENTERGY.COM Date:
5/6/03 11:42AM
Subject:
FOLLOW-UP RAI ON POWER UPRATE STARTUP TESTING REPORT
- Dick, See the attached RAI.
Tom
FOLLOW-UP REQUEST FOR ADDITIONAL INFORMATION POWER UPRATE STARTUP TESTING REPORT SUPPLEMENT ARKANSAS NUCLEAR ONE. UNIT 2 By letter dated March 26, 2003 letter, you submitted additional information regarding your January 31, 2003, power uprate startup testing report. In that letter, you indicated that the vendor attributed the higher than anticipated differential pressure on the secondary side of the steam generator to uncertainties in pressure measurements and line loss estimates. You further indicated that you concluded that instrument error was not a significant contributor to the higher than anticipated differential pressure.
Since your March 26, 2003 letter, only ruled out instrument error as a possible cause of the higher than anticipated differential pressure, please clarify the cause for the higher than anticipated differential pressure. For example, was it attributable to line losses? If so, what was the cause for the higher than anticipated line losses?
C:\\WINDOWS\\TEMP\\GWIOOOO1.TMP Page 1 Mail Envelope Properties (3EB7D7F6.650: 0: 20628)
Subject:
Creation Date:
From:
Created By:
FOLLOW-UP RAI ON POWER UPRATE STARTUP TESTING REPORT 5/6103 11:42AM Thomas Alexion TWA@nrc.gov Recipients ENTERGY.COM RSCHELD (RSCHEID@ENTERGY.COM)
Post Office Action Transferred Delivered Date & Time 05/06/03 11:42AM Route ENTERGY.COM Files ANO2StartupRpt#2.wpd MESSAGE Options Auto Delete:
Expiration Date:
Notify Recipients:
Priority:
Reply Requested:
Return Notification:
Concealed
Subject:
Security:
To Be Delivered:
Status Tracking:
Size 2608 718 Date & Time 05/06/03 11:05AM 05/06/03 11:42AM No None Yes Standard No None No Standard Immediate Delivered & Opened l C.:\\W1ND0WS\\TEMP\\GW)00001.TMP Page 1