ML031270609
| ML031270609 | |
| Person / Time | |
|---|---|
| Site: | Indian Point (DPR-064) |
| Issue date: | 05/06/2003 |
| From: | Milano P NRC/NRR/DLPM/LPD1 |
| To: | Kansler M Entergy Nuclear Operations |
| References | |
| TAC MB5520 | |
| Download: ML031270609 (1) | |
Text
Reporting Requirements 5.6 5.6 Reporting Requirements 5.6.5 CORE OPERATING LIMITS REPORT (COLR) (continued)
Position CPB 4.3-1, -Westinghouse Constant Axial Offset Control (CAOC), Rev. 2, July 1981.
(Specification 3.2.3, Axial Flux Difference (AFD) (Constant Axial Offset Control));
3a.
WCAP-12945-P-A, Volume 1 (Revision 2) and Volumes 2 through 5 (Revision 1), "Code Qualification Document for Best-Estimate Loss-of-Coolant-Accident Analysis," March 1998 (Westinghouse Proprietary);
3b.
NOT USED 3c.
NOT USED 3d.
WCAP-10054-P-A, "SMALL BREAK ECCS EVALUATION MODEL USING NOTRUMP CODE," (W Proprietary). (Specification 3.2.1, Heat Flux Hot Channel Factor (FQ(Z));
3e.
WCAP-10079-P-A, "NOTRUMP NODAL TRANSIENT SMALL BREAK AND GENERAL NETWORK CODE," (W Proprietary). (Specification 3.2.1, Heat Flux Hot Channel Factor (FQ(Z))); and 3f.
WCAP-12610, "VANTAGE+ Fuel Assembly Report," (W Proprietary).
(Specification 3.2.1, Heat Flux Hot Channel Factor).
- c.
The core operating limits shall be determined such that all applicable limits (e.g., fuel thermal mechanical limits, core thermal hydraulic limits, Emergency Core Cooling Systems (ECCS) limits, nuclear limits such as SDM, transient analysis-limits, and accident analysis limits) of the safety analysis are met. -
- d. The COLR, including any midcycle revisions or supplements, shall be provided for each reload cycle to the NRC.
5.6.6 NOT USED (continued)
INDIAN POINT 3 5.0 - 35 Amendment 217