ADMINISTRATIVE CONTROLS PROCEDURES AND PROGRAMS (Continued) 6.8.4 The following programs shall be established, implemented, and maintained:

a.

Primary Coolant Sources Outside Containment A program to reduce leakage from those portions of systems outside containment that could contain highly radioactive fluids during a serious transient or accident to as low as practical levels.

The systems include the core spray, high pressure coolant injection, reactor core isolation cooling, residual heat removal, post-accident sampling system (until such time as a modification eliminates the PASS system as a potential leakage path), safeguard piping fill system, control rod drive scram discharge system, and containment air monitor systems.

The program shall include the following:

1.

Preventive maintenance and periodic visual inspection requirements, and

2.

Integrated leak test requirements for each system at refueling cycle intervals or less.

b.

In-Plant Radiation Monitoring A program which will ensure the capability to accurately determine the airborne iodine concentration in vital areas under accident conditions.

This program shall include the following:

1.

Training of personnel,

2.

Procedures for monitoring, and

3.

Provisions for maintenance of sampling and analysis equipment.

c.

Deleted.

LIMERICK - UNIT I 6-14 Amendment No. -g, 166

ADMINISTRATIVE CONTROLS PROCEDURES AND PROGRAMS (Continued) 6.8.4 The following programs shall be established, implemented, and maintained:

a.

Primary Coolant Sources Outside Containment A program to reduce leakage from those portions of systems outside containment that could contain highly radioactive fluids during a serious transient or accident to as low as practical levels.

The systems include the core spray, high pressure coolant injection, reactor core isolation cooling, residual heat removal, post-accident sampling system (until such time as a modification eliminates the PASS system as a potential leakage path), safeguard piping fill system, control rod drive scram discharge system, and containment air monitor systems.

The program shall include the following:

1.

Preventive maintenance and periodic visual inspection requirements, and

2.

Integrated leak test requirements for each system at refueling cycle intervals or less.

b.

In-Plant Radiation Monitoring A program which will ensure the capability to accurately determine the airborne iodine concentration in vital areas under accident conditions.

This program shall include the following:

1.

Training of personnel,

2.

Procedures for monitoring, and

3.

Provisions for maintenance of sampling and analysis equipment.

c.

Deleted.

LIMERICK -

UNIT 2 6-14 Amendment No. 129