Revised Emergency Plan-Position Specific Procedure EP-PS-248, Environmental Sample Director
ML031140431
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 04/17/2003
From:
Susquehanna
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML031140431 (4)


Text

Apr. 17, 2003 Page 1

of 1 MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2003-20043 USER INFORMATION:

GERL OS M

EMPL#:28401 CA#: 0363 Address U

Pho 254-3194 TRANSMITTAL INFORMATION:

TO:

CERLt.ai aubE H 04/17/2003 LOCATION:

DOCUMENT CONTROL DESK FROM:

NUCLEAR RECORDS DOCUMENT CONTROL CENTER

'NUCSA-2)

Q),.'HE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU:

248 -

248 -

ENVIRONMENTAL SAMPLE DIRECTOR REMOVE MANUAL TABLE OF CONTENTS DATE: 01/08/2003 ADD MANUAL TABLE OF CONTENTS DATE: 04/16/2003 CATEGORY: PROCEDURES TYPE: EP ID:

EP-PS-248 REPLACE:

REV:0 UPDATES FOR HARD COPY MANUALS WILL BE DISTRIBUTED WITHIN 5 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON RECEIPT OF HARD COPY. FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.

Tab 5 EP-PS-248-5 SAMPLE ANALYSIS INFORMATION 1.0 REQUIRED ANALYSES 1.1 The routine analyses that are performed for normal REMP samples are presented on page 2 of this tab. These will be the analyses that will be requested by the sample collection personnel when emergency REMP samples are sent to a cooperating analysis laboratory, unless directed otherwise.

1.2 It is the responsibility of the Environmental Sampling Director to communicate to the SSES Environmental Laboratory Administrative Coordinator any analysis requirements which differ from those in the table on page 2 of this tab.

-Requirements for additional analyses might be established by the Dose Assessment Supervisor.

2.0 REQUIRED ANALYSIS SENSITIVITIES 2.1 The analysis sensitivities presented in the table on page 2 of this tab are currently specified as contractual requirements to be met for the analysis of emergency REMP samples that would be sent to Teledyne Brown Engineering's analysis laboratory in Knoxville, Tennessee, and/or the Framatome Laboratory in Westboro, Massachusetts.

2.2 The analysis sensitivities presented in the table on page 3 of this tab are NRC required analysis sensitivities for media and analyses not presented in the table on page 2. These are the sensitivities that must be met or exceeded when routine REMP samples are analyzed. Normally, the actual sensitivities for the analyses of REMP samples are well below these levels. For the analyses of emergency samples for which required sensitivities are not stated in the table on page 2, an attempt should be made to have the radioanalytical laboratory attain sensitivities below those in the table on page 3.

2.3 If another analysis laboratory (not Framatome or Teledyne) is used, it is the responsibility of the Field Team Director to inform the analysis laboratory of the required analysis sensitivities. Similarly, if any other analysis sensitivities are desired, the Field Team Director is responsible for ensuring that such information is communicated to the appropriate laboratory.

CAUTION:

Requirements for more sensitivity in the performance of sample analyses may impact the expected turnaround time for providing analysis results. Check with the-analysis laboratory to determine if this would be a concern. If the laboratory indicates that greater analysis sensitivities might pose a problem because of the time constraints for reporting results, inquire as to whether providing larger quantities of sample for analysis might obviate the need for longer counting times.

EP-AD-000-209, Revision 4, Page 1 of 3

- s Tab 5 EP-PS-248-5 CAUTION:

Under contract with PPL, Framatome and Teledyne Brown Engineering are required to provide analysis results (with the exception of results for strontium analyses or any analyses that might require extended periods of time to allow for daughter ingrowth, etc.) for emergency environmental samples within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after the samples are received by the laboratory.

ROUTINE ANALYSES PERFORMED ON NORMAL REMP SAMPLES Analysis Type Environmental Medium ross B Gross Gamma 1-131 Alpha Beta Spectroscopic Tritium Radiochemical SR-89/90 Surface Water X

X X

X X+

Drinking Water X

X X

X X

Ground Water X

X Milk X

X Particulate Filters X*

X X

l Charcoal Cartridges X**

Sediment X

Fish X

Soil X

This analysis is only performed on quarterly composites on these filters.

    • lodine-131 results are the only gamma-emitting data normally reported.

+ SR-89-90 analyses are normally only performed if high gross beta results are obtained.

REQUIRED SENSITIVITIES FOR EMERGENCY ANALYSES*

Environmental Medium j SecifiedRadionuclides lodine-131 Cesium-134 I Cesium-137I Strontium-90 Strontium-89 Initial Activity Area Deposition (gCi/m2) 6E-3 1 E-1 1.5E-1 2.5E-2 4E-1 Forage Concentration (g+/-Ci/kg) 3E-4 5E-3 8E-3 1 E-3 2E-2 Peak Milk Activity (ACVI) 1 E-4 1.5E-3 1.5E-3 6E-5 9E-4 These analysis sensitivities are approximately 5% of the FDA's Preventative Protection Action Guides.

EP-AD-000-209, Revision 4, Page 2 of 3

I Tab 5 EP-PS-248-5 NRC REQUIRED DETECTION SENSITIVITIES (LLDs) FOR ROUTINE RADIOLOGICAL ENVIRONMENTAL MONITORING*

Airborne l

Particulate Food or Gas Fish Products Sediments Analysis Water_(pCiA)

(pCi/M 3)

(pCilkg, wet)

(pCi/kg, wet)

(pCi/kg, dry)

Gross Beta 4

0.01 Tritium 2000 Mn-54 15 130 Fe-59 30 260 Co-58 Co-60 15 130 Zn-65 30 260 Zr-95 30 Nb-95 15 1-131 1

0.07 60 Cs-134 15 0.05 130 60 150 Cs-137 18 0.06 150 80 180 Ba-1 40 60 60 La-140 15 15 Milk is not included in the Table above because it has been provided with a special sensitivity requirement for emergency analyses. Refer to the table on the previous page for the required emergency analysis sensitivity for milk.

Wherever blanks appear in the Table above, the NRC has provided no required analysis sensitivities for the media and analysis indicated.

The analysis sensitivities in the Table above should be met as a minimum, if possible. If time permits analyses to be performed to lower sensitivities, then lower sensitivities should be attempted. Consult with the radioanalytical laboratory and the DASU to confirm that it is both possible and desirable, considering the urgency for obtaining analysis results, to analyze for longer periods of time and achieve better sensitivities.

For media and analyses not provided in the Table above, when Framatome or Teledyne Brown Engineering is the radioanalytical laboratory, consult with the lab to determine if PPL has contractually required sensitivities for the routine radiological environmental monitoring program that include those media and analyses, and to find out if those sensitivities can be met with the desired turnaround time for analysis results.

EP-AD-000-209, Revision 4, Page 3 of 3