April 17, 2003 Mr. Roy A. Anderson Chief Nuclear Officer PSEG Nuclear LLC - X04 Post Office Box 236 Hancocks Bridge, NJ 08036
SUBJECT:
SALEM NUCLEAR GENERATING STATION, UNIT NOS. 1 AND 2 -
ENVIRONMENTAL ASSESSMENT AND FINDING OF NO SIGNIFICANT IMPACT RE: ADMINISTRATIVE AND EDITORIAL CHANGES TO TECHNICAL SPECIFICATIONS (TAC NOS. MB7541 AND MB7542)
Dear Mr. Anderson:
Enclosed is a copy of the Environmental Assessment and Finding of No Significant Impact related to your application for amendments to the Salem Nuclear Generating Station (Salem),
Unit Nos. 1 and 2, Technical Specifications (TSs) dated January 29, 2003. The proposed license amendments would allow for administrative and editorial changes to the Salem TSs.
The assessment is being forwarded to the Office of the Federal Register for publication.
Sincerely,
/RA/
Robert J. Fretz, Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-272 and 50-311
Enclosure:
Environmental Assessment cc w/encl: See next page
April 17, 2003 Mr. Roy A. Anderson Chief Nuclear Officer PSEG Nuclear LLC - X04 Post Office Box 236 Hancocks Bridge, NJ 08036
SUBJECT:
SALEM NUCLEAR GENERATING STATION, UNIT NOS. 1 AND 2 -
ENVIRONMENTAL ASSESSMENT AND FINDING OF NO SIGNIFICANT IMPACT RE: ADMINISTRATIVE AND EDITORIAL CHANGES TO TECHNICAL SPECIFICATIONS (TAC NOS. MB7541 AND MB7542)
Dear Mr. Anderson:
Enclosed is a copy of the Environmental Assessment and Finding of No Significant Impact related to your application for amendments to the Salem Nuclear Generating Station (Salem),
Unit Nos. 1 and 2, Technical Specifications (TSs) dated January 29, 2003. The proposed license amendments would allow for administrative and editorial changes to the Salem TSs.
The assessment is being forwarded to the Office of the Federal Register for publication.
Sincerely,
/RA/
Robert J. Fretz, Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-272 and 50-311
Enclosure:
Environmental Assessment cc w/encl: See next page DISTRIBUTION:
PUBLIC PDI-2 R/F SRichards JClifford CRaynor RFretz JTappert OGC ACRS ADAMS Accession Number: ML031110171
- See previous concurrence OFFICE PDI-2/PM PDI-2/LA RLEP/SC*
OGC*
PDI-2/SC NAME RFretz CRaynor JTappert SUttal JClifford DATE 4/8/03 4/8/03 4/1/03 4/7/03 4/17/03 OFFICIAL RECORD COPY
PSEG Nuclear LLC Salem Nuclear Generating Station, Unit Nos. 1 and 2 cc:
Mr. Timothy J. OConnor Vice President - Operations PSEG Nuclear - X15 P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. John T. Carlin Vice President - Engineering PSEG Nuclear - N10 P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. David F. Garchow Vice President - Projects and Licensing PSEG Nuclear - N28 P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. Gabor Salamon Manager - Nuclear Safety and Licensing PSEG Nuclear - N21 P.O. Box 236 Hancocks Bridge, NJ 08038 Jeffrie J. Keenan, Esquire PSEG Nuclear - N21 P.O. Box 236 Hancocks Bridge, NJ 08038 Ms. R. A. Kankus Joint Owner Affairs PECO Energy Company Nuclear Group Headquarters KSA1-E 200 Exelon Way Kennett Square, PA 19348 Lower Alloways Creek Township c/o Mary O. Henderson, Clerk Municipal Building, P.O. Box 157 Hancocks Bridge, NJ 08038 Dr. Jill Lipoti, Asst. Director Radiation Protection Programs NJ Department of Environmental Protection and Energy CN 415 Trenton, NJ 08625-0415 Brian Beam Board of Public Utilities 2 Gateway Center, Tenth Floor Newark, NJ 07102 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Senior Resident Inspector Salem Nuclear Generating Station U.S. Nuclear Regulatory Commission Drawer 0509 Hancocks Bridge, NJ 08038
7590-01-P UNITED STATES NUCLEAR REGULATORY COMMISSION PSEG NUCLEAR, LLC SALEM NUCLEAR GENERATING STATION, UNIT NOS. 1 AND 2 DOCKET NOS. 50-272 AND 50-311 ENVIRONMENTAL ASSESSMENT AND FINDING OF NO SIGNIFICANT IMPACT The U.S. Nuclear Regulatory Commission (NRC) is considering the issuance of amendments to Facility Operating License Nos. DPR-70 and DPR-75, issued to PSEG Nuclear, LLC (the licensee), for operation of the Salem Nuclear Generating Station (Salem), Unit Nos. 1 and 2, located in Salem County, New Jersey. Therefore, as required by Title 10 of the Code of Federal Regulations (10 CFR) Section 51.21, the NRC is issuing this environmental assessment and finding of no significant impact.
ENVIRONMENTAL ASSESSMENT Identification of the Proposed Action:
The proposed action would allow the licensee to make various administrative and editorial changes to the Salem Technical Specifications (TSs) in accordance with the licensees application dated January 29, 2003.
The Need for the Proposed Action:
The proposed action would correct administrative and editorial errors to the Salem TSs.
Environmental Impacts of the Proposed Action:
The NRC has completed its evaluation of the proposed action and concludes, as set forth below, that there are no significant environmental impacts associated with the administrative and editorial changes to the Salem TSs.
The proposed action will not significantly increase the probability or consequences of accidents, no changes are being made in the types of effluents that may be released off site, and there is no significant increase in occupational or public radiation exposure. Therefore, there are no significant radiological environmental impacts associated with the proposed action.
With regard to potential nonradiological impacts, the proposed action does not have a potential to affect any historic sites. It does not affect nonradiological plant effluents and has no other environmental impact. Therefore, there are no significant nonradiological environmental impacts associated with the proposed action.
Accordingly, the NRC concludes that there are no significant environmental impacts associated with the proposed action.
Environmental Impacts of the Alternatives to the Proposed Action:
As an alternative to the proposed action, the staff considered denial of the proposed action (i.e., the no-action alternative). Denial of the application would result in no change in current environmental impacts. The environmental impacts of the proposed action and the alternative action are similar.
Alternative Use of Resources:
The action does not involve the use of any different resource than those previously considered in the Final Environmental Statement related to operation of Salem Nuclear Generating Station, Units 1 and 2, dated April 1973.
Agencies and Persons Consulted:
On March 26, 2003, the staff consulted with the New Jersey State official, Mr. Dennis Zannoni of the New Jersey Department of Environmental Protection, regarding the environmental impact of the proposed action. The State official had no comments.
FINDING OF NO SIGNIFICANT IMPACT On the basis of the environmental assessment, the NRC concludes that the proposed action will not have a significant effect on the quality of the human environment. Accordingly, the NRC has determined not to prepare an environmental impact statement for the proposed action.
For further details with respect to the proposed action, see the licensees letter dated January 29, 2003. Documents may be examined, and/or copied for a fee, at the NRCs Public Document Room (PDR), located at One White Flint North, Public File Area O1 F21, 11555 Rockville Pike (first floor), Rockville, Maryland. Publicly available records will be accessible electronically from the Agencywide Documents Access and Management System (ADAMS) Public Electronic Reading Room on the Internet at the NRC Web site, http://www.nrc.gov/reading-rm/adams.html. Persons who do not have access to ADAMS or who encounter problems in accessing the documents located in ADAMS, should contact the NRCs PDR reference staff by telephone at 1-800-397-4209 or 301-415-4737, or by e-mail to pdr@nrc.gov.
Dated at Rockville, Maryland, this 17th day of April, 2003.
FOR THE NUCLEAR REGULATORY COMMISSION
/RA/
James W. Clifford, Chief, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation