Technical Specifications 4.4.5.5.b & 6.9.1.5.b: Report on Steam Generator Tube Inservice Inspection Results
ML030930374
Person / Time
Site: Davis Besse 
(NPF-003)
Issue date: 03/31/2003
From: Myers L
FirstEnergy Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
2944
Download: ML030930374 (31)


Text

FENOC 5501 North State Route 2 FirstEnergy Nuclear Operating Company Oak Harbor, Ohio 43449 Low W. Myers 419-321-7599 Chief Operating Officer Fax 419-321-7582 Docket Number 50-346 License Number NPF-3 Serial Number 2944 March 31, 2003 United States Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555-0001 Subject Technical Specifications 4.4.5.5.b and 6.9.1.5.b: Report of Steam Generator Tube Inservice Inspection Results Ladies and Gentlemen:

This letter is submitted in accordance with the Davis-Besse Nuclear Power Station, Unit Number 1, Operating License, Appendix A Technical Specifications. Technical Specification Surveillance Requirement 4.4.5.5.b and Administrative Controls requirement 6.9.1.5.b require the FirstEnergy Nuclear Operating Company (FENOC) to submit the complete results of the Steam Generator tube inservice inspection. These results are presented in Attachment 1.

Should you have any questions or require additional information, please contact Mr. Patrick McCloskey, Manager - Regulatory Affairs, at (419) 321-8450.

Very truly yours, MAR Attachments Enclosure cc: J. E. Dyer, Regional Administrator, NRC Region IlIl J. B. Hopkins, NRC/NRR Senior Project Manager C. S. Thomas, NRC Region l1l, DB-1 Senior Resident Inspector Utility Radiological Safety Board ApDl

?

i Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 1 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Eddy Current Examination Techniques The tubing in the Once Through Steam Generators (OTSG's) at the Davis-Besse Nuclear Power Station Unit #1 was examined in February and March, 2002, during the 13th Refueling Outage. The examinations were conducted by Framatome Technologies to meet the requirements of the Davis-Besse Unit #1 Technical Specifications.

The eddy current examinations were performed utilizing various eddy current probes.

The bobbin coil technique was used to perform the standard ASME Code examination for flaw detection. This technique was applied to the complete length of all in-service tubes. The rotating plus point and pancake techniques (RPP) were used to examine specific areas of interest. These areas included upper tube end roll expansion regions, critical areas of tubes bordering the sleeved (lane & wedge) region, non-stress relieved roll transitions, the lower tubesheet crevice region and select dent locations. These techniques were also used to characterize all indications reported by the bobbin technique and the pancake coil was used to provide final depth sizing of Tube Support Plate wear indications. Both plus point and bobbin techniques were used to examine tube sleeves. The rotating plus point probe was applied to the rolled regions and lower sleeve end while the bobbin probe was used to examine the unrolled portion. The rotating plus point technique was used to examine plugs. contains the Eddy Current Identification Codes used in the tables in this attachment.

? C i

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 2 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS STEAM GENERATOR #1 (B)

Tablel: Number and Extent of Tubes Inspected SG #1:

Examination Number Technique Tubes Extent Inspected Bobbin All In-Service Full Length 15,353 Tubes Bobbin All Sleeves Full Length 212 Tubes Plus Point 59% of Sleeves Sleeve Roll 126 Tubes Transitions Plus Point and 57% of In-Upper Tube Roll 8,844 Tubes Rotating Service Tubes Expansion Area Pancake Coil Plus Point and All Non-Stress Upper Tube Roll 3 Tubes Rotating Relieved Tube Expansion Area Pancake Coil Roll Expansions Plus Point 72% of Hot Leg Plug Pressure 69 Plugs Roll Plugs Boundary Plus Point and Tubes bordering 15 TSP +/-1 inch 80 Tubes Rotating the Sleeved and UTS Pancake Coil Region Secondary Face

-1 inch to + 4 inches Plus Point and All Tubes with Flaw-Like 364 Locations Rotating Flaw-Like Indication Area Pancake Coil Indications Plus Point and All Dent Dent Area 136 Dents Rotating Locations above Pancake Coil the 14th TSP and 60% of the remaining Dent Population Plus Point and 23% of Lower Sludge Pile 500 Tubes Rotating Tube Sheet Region at LTS +4 Pancake Coil sludge pile inches to LTS -

16 inches Bobbin All deplugged Full Length 8 Tubes tubes for profileometry

ii I

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 3 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 2: Location and Percent of Wall Thickness Penetration for Each Imperfection-SG #1:

OTSG Row Tube -Ind Location

., %TW Indication 1B 1

6 TWD 14S

-0.73 21 1

1B 2

2 TWD 14S

-0.47 16 2

1B 2

4 TWD 14S

-0.72 12 3

1B 2

27 TWD 12S

+0.59 19 4

1B 3

12 TWD 10S

+0.61 12 5

1B 3

31 TWD 12S

+0.66 17 6

1B 4

16 TWO 10S

+0.49 9

7 1B 4

17 TWD 10S

+0.64 18 8

1B 4

39 TWD 12S

-0.62 12 9

1B 5

9 TWO 08S

+0.67 15 10 1B 5

13 TWD 10S

+0.60 17 11 1B 5

13 TWD 10S

+0.64 18 12 1B 5

31 TWD 11S

-0.81 19 13 1B 5

44 TWD 13S

+0.55 19 14 1B 6

13 TWD 10S

+0.61 15 15 1B 6

39 TWD 09S

+0.56 18 16 1B 6

49 TWD 14S

+0.57 18 17 1B 6

50 TWD 13S

+0.63 25 18 1B 7

10 TWD 10S

+0.60 22 19 1B 7

43 TWD 11S

-0.79 15 20 1B 8

48 TWD 11S

-0.81 13 21 1B 9

52 TWD 13S

+0.49 22 22 1B 9

54 TWO 14S

+0.52 14 23 1B 9

60 TWD 09S

+0.15 7

24 1B 10 24 TWD 09S

-0.66 13 25 1B 10 40 TWD 14S

+0.63 20 26 1B 10 56 TWD 14S

-0.72 20 27 1B 10 65 TWD 13S

+0.59 14 28 1B 10 65 TWD 14S

+0.61 10 29 1B 10 65 TWD 14S

-0.62 23 30 1B 11 24 TWD 13S

+0.66 15 31 1B 11 48 TWO 08S

+0.58 21 32 1B 11 58 TWD 06S

+0.73 12 33 1B 11 58 TWD 14S

+0.61 16 34 1B 12 50 TWD 08S

+0.57 15 35 1B 13 2

TWO 12S

+0.65 20 36 1B 13 52 TWD 14S

+0.58 14 37 1B 13 57 TWD 11S

-0.81 16 38 1B 14 9

TWD 01S

-0.31 15 39

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 4 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 2: Location and Percent of Wall Thickness Penetration for Each Imperfection-SG #1:

OTSG Row Tube

Ind S -^-"Location'.-

%TW Indication-

,. ^_,-

_,dX

^-

I@r!(founit f

1B 14 64 TWD 14S

+0.61 14 40 1B 14 73 TWD 11S

+0.19 11 41 1B 14 74 TWD 11S

+0.60 18 42 1B 14 74 TWD 12S

-0.26 28 43 1B 15 2 TWD 12S

+0.57 17 44 1B 15 55 TWD 14S

+0.58 13 45 1B 15 67 TWD 09S

+0.64 21 46 1B 15 67 TWD 09S

-0.63 15 47 1B 15 76 TWD 09S

-0.29 15 48 1B 15 76 TWD 13S

+0.62 15 49 1B 16 69 TWD 09S

+0.57 18 50 1B 16 78 TWD 14S

+0.65 18 51 1B 17 77 TWD 06S

+0.58 12 52 1B 17 79 TWD 09S

+0.58 12 53 1B 17 79 TWD 09S

-0.49 19 54 1B 17 81 TWD 1OS

+0.49 19 55 1B 18 4

TWD 09S

+0.63 18 56 1B 18 47 TWD 11S

-0.74 18 57 1B 18 79 TWD 09S

+0.58 22 58 1B 18 80 TWD 09S

+0.60 17 59 1B 18 80 TWD 09S

-0.74 12 60 1B 19 15 TWD 08S

+0.40 17 61 1B 20 41 TWD 09S

-0.74 18 62 1B 20 79 TWD 09S

+0.54 19 63 1B

-20 79 TWD 09S

-0.75 11 64 1B 20 84 TWD 09S

+0.21 15 65 1B 22 5

TWD 09S

+0.62 28 66 1B 22 88 TWD 09S

+0.62 24 67 1B 22 93 SAI 15S

-2.33 28 68 1B 23 78 TWD 08S

+0.48 12 69 1B 23 80 TWD 14S

+0.51 17 70 1B 23 94 MAI 15S

-1.99 24 71 lB 25 97 TWD 10S

+0.67 13 72 1B 26 14 TWD 12S

-0.78 10 73 1B 26 80 TWD 14S

+0.62 15 74 1B 27 63 SAA UTE

-0.26 N/A 75 1B 27 64 SAA UTE

-0.30 NIA 76 1B 27 97 TWD 09S

+0.61 18 77 1B 28 96 TWD 09S

+0.61 22 78 1B 28 99 TWD 09S

+0.68 17 79 1B 28 100 TWD lOS

+0.46 16 80

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 5 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 2: Location and Percent of Wall Thickness Penetration for Each Imperfection-SG #1:

OTSG Row Tube Ind Location

%TW Indication rCount 1B 29 102 TWD 10S

+0.62 22 81 1B 30 104 TWD 10S

-0.73 18 82 1B 31 98 TWD 07S -0.76 16 83 1B 31 104 TWD 09S

+0.64 13 84 1B 36 5

TWD 10S

+0.37 20 85 1B 36 99 MAA UTE

-0.28 N/A 86 1B 40 52 SVI 06S

+0.10 36 87 1B 41 108 TWO 09S

-0.34 18 88 1B 41 112 TWD 09S

+0.66 9

89 1B 41 114 TWD 05S

-0.73 8

90 1B 42 112 TWD 09S

-0.58 16 91 1B 43 116 TWD 10S

+0.59 19 92 1B 44 117 TWD 10S

+0.65 16 93 1B 45 118 TWD 10S

+0.53 17 94 1B 46 114 TWD 08S

+0.62 12 95 1B 48 121 TWD 08S

-0.50 19 96 1B 50 122 TWO 09S +0.62 8

97 1B 52 89 TWD 05S

-0.74 18 98 1B 52 120 TWD 07S -0.46 14 99 1B 53 126 TWD 12S -0.75 19 100 1B 54 1

TWD 11S

-0.63 16 101 1B 54 1

TWO 14S

-0.59 19 102 1B 54 116 TWO 03S

+0.61 11 103 1B 56 122 TWD 09S

+0.47 18 104 1B 57 2

TWD 05S

-0.77 9

105 1B 58 1

TWD 12S

+0.63 16 106 1B 60 113 TWO 03S

-0.72 16 107 1B 60 127 TWD 09S

+0.62 15 108 1B 60 128 TWD 10S

+0.51 25 109 1B 61 121 TWD 09S +0.69 20 110 1B 61 125 TWD 10S

+0.41 26 111 1B 63 126 TWD 09S

+0.65 23 112 1B 63 128 SAI UTS

-13.71 14 113 1B 64 27 TWD 04S -0.73 20 114 1B 65 58 MVI UTE

-1.58 78 115 1B 65 62 SVI 04S

+30.78 62 116 1B 67 1

TWD 12S

+0.63 22 117 1B 67 1

TWD 12S

-0.02 21 118 1B 67 2

SVI UTS

+9.62 49 119 1B 67 48 TWD 03S

+0.74 10 120 1B 67 118 TWD 05S

-0.79 12 121

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 6 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 2: Location and Percent of Wall Thickness Penetration for Each Imperfection-SG #1:

OTSG,Row. Tube, ind L cation,

%TW Indication Cot~nt" 1B 68 3

TWD 15S

-0.66 8

122 11B 68 63 MVI 03S

+23.86 47 123 11B 68 63 MVI 03S

+32.38 57 124 11B 69 2

TWD 12S

+0.47 17 125 1B 69 3

TWD 12S

+0.65 16 126 1B 69 60 TWD 04S

+0.49 8

127 1B 69 66 TWD 09S

+0.72 15 128 1B 70 2

TWD 12S

+0.46 20 129 1B 70 6

TWD 12S

+0.62 18 130 1B 70 14 TWD 12S

+0.65 16 131 1B 70 37 TWD 06S

+0.45 10 132 1B 70 62 SVI 03S

+28.80 48 133 1B 71 2

TWD 13S

-0.70 17 134 1B 71 28 TWD 11S

+0.65 12 135 1B 72 2

TWD 12S

-0.65 14 136 1B 72 59 SVI 04S

+4.91 54 137 1B 72 60 SAI 06S

+29.66 56 138 1B 73 4

TWOD 13S

-0.39 13 139 1B 73 9

TWO 12S

+0.71 15 140 1B 73 12 TWD 12S

+0.61 17 141 1lB 73 62 SVI 04S

+9.86 42 142 1B 74 4

TWD 13S

+0.68 16 143 1B 77 43 TWD 04S

-0.71 15 144 1B 77 68 TWO 03S

-0.12 11 145 1B 80 6

TWD 09S

+0.40 16 146 1B 80 70 SVI 03S

+38.11 55 147 1B 81 65 TWD 11S

+0.50 12 148 1B 81 126 TWD 09S

-0.62 8

149 1B 83 4

TWD 10S

+0.57 10 150 lB 83 66 SVI 03S

+21.44 54 151 lB 83 66 SVI 04S

+1.33 50 152 1B 86 103 TWD 04S

-0.72 17 153 11B 87 1

TWD 06S

-0.66 8

154 1B 88 3

TWD 09S

+0.57 9

155 1B 89 54 SVI 06S - +0.30 0

156 1B 92 1

TWD 14S

+0.53 12 157 1B 94 1

TWD 08S

-0.67 12 158 1B 95 1

SAA UTE

-0.39 N/A 159 1B 95 128 SAI UTS

-14.22 0

160 1B 96 124 SVI 05S

+0.29 24 161 1lB 99 26 SVI UTE

-1.74 57 162

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 7 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 2: Location and Percent of Wall Thickness Penetration for Each Imperfection-SG #1:

OTSG Row Tube Ind Location',,"

%TW Indication 7Count' 1B 99 94 TWD 06S

-0.59 15 163 lB 101 124 TWD 12S

-0.63 18 164 1B 102 73 SVI 06S

+0.07 11 165 1B 103 113 TWD 07S

+0.60 10 166 1B 104 32 SAA UTE

-0.25 N/A 167 1B 104 121 TWD 03S

-0.67 19 168 1B 109 69 TWD 06S

+0.51 20 169 1B 111 6

TWD 06S

+0.55 10 170 1B 112 71 TWD 03S

-0.77 14 171 1B 113 9 TWD 08S

+0.65 15 172 1B 114 4

TWD 09S

+0.65 13 173 1B 115 113 TWD 1OS -0.74 18 174 lB 115 114 TWD 07S

-0.55 27 175 lB 116 111 TWD 10S

-0.62 19 176 1B 117 1

TWD 09S

+0.58 11 177 1 B 119 105 TWD 10S

+0.66 17 178 1 B 121 41 TWD 04S

+0.45 10 179 1 B 121 90 TWD 07S

+0.65 18 180 1B 121 105 TWD lOS

+0.66 11 181 1B 121 105 TWD 10S

-0.63 18 182 1 B 122 6

TWD 08S

-0.33 12 183 1 B 122 104 TWOD 10S

-0.58 36 184 1 B 123 66 SAI UTS

-4.42 38 185 lB 123 86 TWD 03S

+0.69 12 186 lB 123 86 TWD 03S

-0.66 13 187 1 B 123 100 TWD lOS

+0.59 19 188 1 B 123 102 TWD lOS

-0.61 27 189 lB 124 100 TWD 10S

-0.67 21 190 1B 126 98 TWD 10S

+0.65 15 191 1B 126 98 TWD loS

-0.57 22 192 lB 127 49 TWD 09S

-0.79 15 193 1B 127 76 TWD 07S

+0.13 11 194 1B 127 76 TWD 07S

-0.55 11 195 1B 127 77 TWD 10S

-0.71 13 196 1B 128 94 TWD lOS

-0.55 27 197 1B 128 95 TWD 11S

-0.64 18 198 lB 129 9

TWD 06S

+0.70 10 199 1B 129 93 TWD 10S

-0.61 24 200 1B 129 94 TWO 10S

-0.74 20 201 1B 129 94 TWD 11S

-0.72 19 202 lB 130 73 SAA UTE

-0.34 N/A 203

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 8 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 2: Location and Percent of Wall Thickness t -

B

.Z.L...

-l 24 Penetration Tor Eacn ImperieCuurI-OV Hf I; OTSG Row Tube

, Ind',

Location r'

%TW Indication I B 130 74 TWD 05S

-0.01 10 204 1B 130 93 TWD 11S

-0.77 20 205 1B 130 93 SVI 15S

-4.22 0

206 1B 131 6

TWD 10S

-0.73 12 207 1B 131 89 TWD 12S

-0.26 19 208 1B 132 6

TWD 10S

+0.66 17 209 1B 133 2

TWD 09S

-0.64 11 210 1B 133 86 TWD 14S

-0.71 21 211 1B 134 1

SAI 15S

-1.48 0

212 1B 134 50 TWD 10S

+0.72 14 213 1B 134 84 TWD 12S

+0.64 13 214 1B 135 54 TWD 03S

+0.44 15 215 1B 135 79 TWD 06S

+0.69 16 216 11B 136 44 TWD 07S

+0.35 12 217 1B 137 5

TWD 09S

-0.71 16 218 1B 138 6

TWO 10S

+0.65 11 219 1B 138 75 TWD 10S

-0.70 26 220 1B 139 7

TWD 10S

+0.61 17 221 lB 140 2

TWD 12S

-0.71 15 222 1B 141 1

TWD 12S

-0.70 10 223 1B 141 47 TWD 14S

+0.53 13 224 1B 141 67 TWD 14S

+0.58 19 225 1B 141 68 TWD 14S

+0.26 18 226 1B 141 68 TWD 14S

-0.70 11 227 1B 142 37 SVI 07S

+0.03 24 228 1B 142 56 TWD 03S

+0.40 10 229 1B

-143 46 TWD 14S

+0.57 14 230 1B 145 30 TWD 03S

+0.69 14 231 1B 145 42 TWD 14S

+0.62 16 232 1B 147 20 TWD 10S

-0.71 17 233 1B 147 25 TWD 09S

-0.70 12 234 1B 147 33 TWD 10S

+0.67 26 235 1B 148 22 TWD 09S

-0.51 21 236 1B 148 39 TWD 12S

+0.54 12 237 1B 148 41 TWD 11S

+0.39 13 238 1B 148 41 TWD 11S

-0.05 14 239 1B 148 41 TWD 11S

-0.62 14 240 1B 149 19 TWD 09S

-0.71 17 241 1B 149 28 TWD 11S

-0.20 18 242 1B 149 30 TWD 10S

+0.72 12 243 1 B 149 30 TWD 10S

-0.62 12 244

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 9 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 2: Location and Percent of Wall Thickness Penetration for Each Imperfection-SG #1:

OTSG Row, Tube Ind' SLocation, --

%TW lndication Count' 1B 149 32 TWD 12S

+0.29 16 245 1B 149 33 TWD 12S

+0.35 14 246 1B 149 33 TWD 12S

-0.65 14 247 1B 150 19 SAI UTS

-19.78 51 248 1B 150 20 TWD lOS

+0.64 19 249 1B 150 23 TWD 12S

+0.67 14 250 1B 150 26 TWD 11S

-0.13 13 251 1B 150 27 TWD 11S

-0.16 13 252 1B 151 5 TWD lOS

-0.74 18 253 1B 151 5 TWD 12S

+0.49 18 254 1B 151 9 TWD 14S

+0.56 22 255 1B 151 13 TWD 14S

-0.19 33 256 1B 151 14 TWD 10S

+0.74 13 257 1B 151 14 TWD 11S

-0.74 15 258 1B 151 16 TWD 14S

-0.61 24 259

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 10 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 3: Identification of Tubes Repaired-SG #1:

SIG ROW TUBE Reason for Repair l Tube Count Repaired by Plugging 1-B 22 93 SAI @ 15S -2.33 1

1-B 23 94 MAI@ 15S-1.99 2

1-B 39 90 Capture Tube B 40-91 3

1-B 39 91 Capture Tube B 40-91 4

1-B 40 52 SVI @ 06S +0.1 5

1-B 40 90 Capture Tube B 40-91 6

1-B 40 92 Capture Tube B 40-91 7

1-B 41 90 Capture Tube B 40-91 8

1-B 41 91 Capture Tube B 40-91 9

1-B 52 71 Capture Tube B 53-72 10 1-B 52 72 Capture Tube B 53-72 11 1-B 53 71 Capture Tube B 53-72 12 11-B 53 73 Capture Tube B 53-72 13 1-B 54 72 Capture Tube B 53-72 14 11-B 54 73 Capture Tube B 53-72 15 1-B 58 128 Capture Tube B 58-129 16 1-B 59 124 Capture Tube B 58-129 17 1-B 60 129 Capture Tube B 58-129 18 1-B 63 128 SAI @ UTS -13.71 19 1-B 65 62 SVI @ 04S +30.78 20 1-B 67 2

SVI @ UTS +9.62 21 1-B 68 63 MVI @ 03S +23.86 22 IMVI @ 03S +32.38 1-B 70 62 SVI @ 03S +28.8 23 1-B 72 59 SVI @ 04S +4.91 24 1-B 72 60 SAI @ 06S +29.66 25 11-B 72 117

- Capture Tube B 73-117 26 1-B 72 118 Capture Tube B 73-117 27 1-B 73 62 SVI @ 04S +9.86 28 1-B 73 116 Capture Tube B 73-117 29 1-B 73 118 Capture Tube B 73-117 30 1-B 74 112 CaptureTubeB73-117 31 11-B 74 113 Capture Tube B 73-117 32 1-B 80 70 SVI @ 03S +38.11 33 1-B 83 66 SVI @ 03S +21.44 34 SVI @ 04S +1.33 1-B 89 54 SVI @ 06S +0.3 35 1-B 91 53 Capture Tube B 92-55 36 1-B 91 54 Capture Tube B 92-55 37

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 1 1 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Tahip 3-Idantification of Tubes Renaired-SG #1:

SIG ROW TUBE Reason for Repair Tube Count 1-B 92 54 Capture Tube B 92-55 38 1-B 92 56 Capture Tube B 92-55 39 1-B 93 51 Capture Tube B 93-52 40 1-B 93 53 Capture Tube B 93-52 41 1-B 94 54 Capture Tube B 93-52 42 1-B 94 55 Capture Tube B 93-52 43 1-B 95 128 SAI @ UTS -14.22 44 1-B 96 124 SVI @ 05S +0.29 45 1-B 102 73 SVI @ 06S +0.07 46 1-B 123 66 SAI @ UTS -4.42 47 1-B 126 65 Capture Tube B 127-65 48 1-B 126 66 Capture Tube B 127-65 49 1-B 127 64 Capture Tube B 127-65 50 1-B 127 66 Capture Tube B 127-65 51 1-B 128 63 Capture Tube B 127-65 52 1-B 128 64 Capture Tube B 127-65 53 1-B 130 93 SVI @ 15S -4.22 54 1-B 134 1

SAI @ 15S -1.48 55 1-B 142 37 SVI @ 07S +0.03 56 1-B 150 19 SAI @ UTS -19.78 57 Repaired by Repair Roll 1-B 27 63 SAA @ UTE -0.26 1

1-B 27 64 SAA @ UTE -0.3 2

1-B 36 99 MAA @ UTE-0.28 3

1-B 65 58 MVI @ UTE -1.58 4

1-B 95 1

SAA @ UTE-0.39 5

1-B 99 26 SVI @ UTE -1.74 6

1-B 104 32 SAA @ UTE -0.25 7

1-B 130 73 SAA @ UTE -0.34 8

Total New Repaired Tubes 65

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 12 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS STEAM GENERATOR #2 (A)

Table 4: Number and Extent of Tubes Inspected SG-#2:

Examination Number Technique Tubes Extent Inspected Bobbin All In-Service Full Length 15,021 Tubes Bobbin All Sleeves Full Length 199 Tubes Plus Point 64% of Sleeves Sleeve Roll 128 Tubes Transitions Plus Point and 57% of In-Upper Tube Roll 8,616 Tubes Rotating Service Tubes Expansion Area Pancake Coil Plus Point and All Non-Stress Upper and Lower 3 Tubes Rotating Relieved Tube Tube Roll Pancake Coil Roll Expansions Expansion Area Plus Point 66% of Hot Leg Plug Pressure 277Plugs Roll Plugs Boundary Plus Point and Tubes bordering 15 TSP +1 inch 85 Tubes Rotating the Sleeved and UTS Pancake Coil Region Secondary Face

-1 inch to + 4 inches Plus Point and All Tubes with Flaw-Like 479 Locations Rotating Flaw-Like Indication Area Pancake Coil Indications Plus Point and All Dent Dent Area 75 Dents Rotating Locations above Pancake Coil the 14th TSP and 60% of the remaining Dent Population Plus Point and 23% of Lower Sludge Pile 500 Tubes Rotating Tube Sheet Region at LTS +4 Pancake Coil sludge pile inches to LTS -

16 inches Bobbin All deplugged Full Length 47 Tubes tubes for profileometry

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 13 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 5: Location and Percent of Wall Thickness Penetration for Each Imperfection SG-#2:

'OTSG!. -ROW,, TUBE

'IND41 4KLOCATIONt

-%TW-Indication, 2A 1

2 TWD 11S

+0.68 9

1 2A 1

2 TWD 11S

-0.60 16 2

2A 3

3 TWD 14S

-0.57 17 3

2A 3

11 TWD 08S

-0.25 12 4

2A 3

29 TWD 13S

-0.73 14 5

2A 3

33 TWD 13S

+0.69 16 6

2A 4

1 TWD 14S

+0.66 13 7

2A 4

4 TWD 14S

-0.56 20 8

2A 4

33 TWD 09S

+0.65 17 9

2A 4

35 TWD 13S

-0.72 18 10 2A 4

40 TWD 12S

-0.66 10 11 2A 4

41 TWD 13S

+0.63 22 12 2A 5

12 TWD 10S

+0.66 15 13 2A 5

20 TWD 08S

+0.32 17 14 2A 5

41 TWD 13S

-0.66 13 15 2A 5

42 TWD 13S

+0.68 18 16 2A 5

42 TWD 13S

-0.67 15 17 2A 5

45 TWD 13S

+0.73 16 18 2A 5

45 TWD 13S

-0.60 13 19 2A 5

45 TWD 14S

-0.71 18 20 2A 5

46 TWD 13S

+0.70 19 21 2A 6

47 TWD 14S

+0.65 15 22 2A 7

12 TWD 10S

+0.41 11 24 2A 7

16 TWD 07S

+0.70 7

25 2A 9

60 TWD 14S

-0.76 14 26 2A 10 2

TWD 14S

-0.66 13 27 2A 11 21 TWD 14S

+0.58 7

28 2A 11 21 TWD 14S

-0.63 8

29 2A 12 1

TWD 13S

-0.68 23 30 2A 12 2

TWD 13S

-0.60 20 31 2A 12 22 TWD 07S

-0.55 9

32 2A 12 39 SAA UTE

-0.27 N/A 33 2A 12 39 SVI UTE

-4.89 8

34 2A 13 2

TWD 13S

-0.63 25 35 2A 13 66 TWD 07S

+0.65 17 36 2A 14 5

TWO 14S

-0.70 14 37 2A 14 10 SPA UTE

-0.30 N/A 38 2A 15 7

TWD 13S

-0.74 9

39 2A 15 10 MAA UTE

-0.32 N/A 40 2A 15 70 SMA UTE

-0.33 N/A 41

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 14 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 5: Location and Percent of Wall Thickness Penetration for Each Imperfection SG-#2:

'OTSG ROW TUBE IND

-OCATIONi.7

%TW Indication 2A 16 2

TWD 13S

-0.69 28 42 2A 16 13 TWD 09S -0.63 13 43 2A 16 18 TWD 06S

+0.00 11 44 2A 16 80 TWD 11S

+0.57 18 45 2A 17 1

TWD 13S

-0.63 20 46 2A 17 81 TWO 13S

-0.72 18 47 2A 18 1

TWD 13S

-0.59 27 48 2A 18 13 MM UTE

-0.28 N/A 49 2A 18 14 MAA UTE

-0.16 N/A 50 2A 19 53 TWD 12S

-0.65 19 51 2A 20 27 TWD 15S

-0.68 6

52 2A 20 80 TWD 10S

+0.62 12 53 2A 21 10 TWD 03S

-0.67 19 54 2A 21 16 SM UTE

-0.14 N/A 55 2A 21 76 MM UTE

-0.20 N/A 56 2A 21 77 SM UTE

-0.34 N/A 57 2A 22 1

TWD 12S

+0.65 22 58 2A 24 1

TWD 08S

+0.71 23 59 2A 24 46 TWD 06S -0.42 10 60 2A 25 1

TWD 08S

+0.47 24 61 2A 25 1

TWD 12S

+0.57 22 62 2A 25 1

TWD 12S

-0.50 21 63 2A 25 1

TWD 13S

+0.67 18 64 2A 25 1

TWD 13S

-0.59 25 65 2A 25 88 TWD 08S

+0.67 17 66 2A 27 21 SM UTE

-0.30 N/A 67 2A 27 65 SM UTE

-0.28 N/A 68 2A 30 1

TWD 14S

+0.38 19 69 2A 30 1

TWD 14S

-0.61 15 70 2A 30 23 MM UTE

-0.29 N/A 71 2A 31 13 TWD 08S

-0.47 13 72 2A 32 61 TWD 06S

-0.39 18 73 2A 34 1

TWD 12S

+0.64 19 74 2A 34 84 TWD 03S

-0.57 10 75 2A 35 1

TWD 11S

-0.42 21 76 2A 35 1

TWD 13S

-0.58 21 77 2A 35 2

TWD 09S

-0.81 10 78 2A 35 68 TWD 06S

-0.45 15 79 2A 36 1

TWD 12S

+0.55 24 80 2A 36 1

TWD 13S

-0.60 21 81 2A 36 2

TWD 13S

-0.58 24 82

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 15 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 5: Location and Percent of Wall Thickness Penetration for Each Imperfection SG-#2:

'OTSG rROW- 'TUBE, :-IND,` "LOCATION",

%TW~ Indication Count~

2A 37 1

TWD 12S

+0.49 20 83 2A 37 1

TWD 13S

-0.52 14 84 2A 37 2

TWD 13S

-0.65 21 85 2A 37 2

TWD 14S

-0.62 11 86 2A 37 56 TWD 06S

+0.67 13 87 2A 37 75 TWD 06S

+0.54 8

88 2A 38 3

TWD 12S

+0.64 16 89 2A 39 62 TWD 06S

-0.47 12 90 2A 39 113 TWO 14S

-0.78 1 1 91 2A 39 116 TWD 13S

-0.79 16 92 2A 40 36 TWOD 07S

+0.20 11 93 2A 41 3

TWD 13S

-0.60 20 94 2A 41 36 TWOD 06S

+0.53 22 95 2A 41 36 TWD 06S

-0.39 17 96 2A 42 1

TWD 13S

-0.63 18 97 2A 42 1

TWD 14S

-0.52 18 98 2A 42 67 SVI 06S

-0.19 0

99 2A 43 1

TWOI 13S

-0.62 19 100 2A 43 1

TWD 14S

-0.65 17 101 2A 44 117 SVI 08S

-0.01 0

102 2A 45 120 SVI UTE

-0.32 42 103 2A 46 116 SAC UTE

-0.28 N/A 104 2A 48 14 TWOM 055

-0.48 16 105 2A 50 122 TWOD 0S

+0.67 16 106 2A 51 54 TWD 06S

+0.31 11 107 2A 52 1

TWO 12S

+0.59 23 108 2A 52 1

TWD 13S

-0.61 22 109 2A 52 45 TWOD 06S

-0.24 12 110 2A 52 66 SVI 05S

+0.29 14 111 2A 52 125 TW 135S

-0.71 21 112 2A 54 1

TWD 07S

+0.56 10 113 2A 54 1

TWOD 1S

-0.66 15 114 2A 54 1

TWD 12S

+0.63 14 115 2A 54 50 TWOD 06S

+0.42 11 116 2A 55 1

TWD 12S

+0.55 16 117 2A 58 1

TWD 11S

-0.60 18 118 2A 58 1

TWD 12S

+0.61 18 119 2A 62 2

SAA UTE

-0.21 N/A 120 2A 62 2

MVI UTE

-4.67 12 121 Post Re-roll Defect

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 16 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 5: Location and Percent of Wall Thickness Penetration for Each Imperfection SG-#2:

OTSG,., ROW TUBEt J IND

-'LOCATION -%TW lndication Count 2A 63 1

TWO 12S

+0.46 16 122 2A 63 1

TWD 14S

+0.40 17 123 2A 63 1

SCI UTE

-0.27 44 124 2A 63 3

MAA UTE

-0.23 N/A 125 2A 63 78 SAI UTE

-1.22 99 126 2A 64 51 SVI 04S

+16.69 50 127 2A 65 1

SAA UTE

-0.24 N/A 128 2A 65 70 SVI 04S

+7.34 44 129 2A 65 70 SVI 04S

+8.59 59 130 2A 65 70 SVI 04S

+9.16 49 131 2A 65 73 SVI 04S

+5.14 53 132 2A 65 73 TWD 11S

+0.72 17 133 2A 66 1

SAA UTE

-0.26 N/A 134 2A 66 61 SVI 04S

+13.58 57 135 2A 66 68 SAI 04S

+5.76 51 136 2A 67 52 SVI 04S

+16.13 54 137 2A 67 67 SVI 04S

+10.12 56 138 2A 68 1

TWD 14S

+0.58 17 139 2A 68 3

MAA UTE

-0.16 N/A 140 2A 68 3

SVI UTE

-4.90 0

141 Post Re-roll Defect 2A 68 4

SAA UTE

-0.25 N/A 142 2A 68 23 TWD 09S

+0.72 14 143 2A 68 51 SVI 04S

+14.04 55 144 2A 68 51 SVI 04S

+17.87 55 145 2A 70 1

TWD 14S

+0.65 17 146 2A 70 63 SVI 04S

+3.40 37 147 2A 71 2

TWD 14S

-0.68 14 148 2A 71 4

TWOD 11S

+0.49 15 149 2A 71 7

TWOD 11S

+0.62 8

150 2A 71 65 SVI 06S

+12.87 59 151 2A 71 65 SVI 06S

+13.73 59 152 2A 71 65 SVI 06S

+14.25 62 153 2A 71 65 SVI 06S

+15.97 53 154 2A 71 66 SVI 03S

+0.44 40 155 2A 71 72 SVI 04S

+1.51 49 156 2A 71 72 SVI 04S

+2.49 34 157 2A 71 72 SVI 04S

+3.12 52 158 2A 71 72 SVI 04S

+4.70 46

- 159 2A 72 1

TWD 08S

+0.59 13 160

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 17 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 5: Location and Percent of Wall Thickness Penetration for Each Imperfection SG-#2:

OTSG' ;ROWF3 TUBE IND LOCATION

%TW, Indication Count 2A 72 1

TWD 14S

+0.49 19 161 2A 72 35 TWD 14S

+0.53 9

162 2A 72 51 TWD 10S

+0.55 10 163 2A 72 66 TWD 03S

+0.53 16 164 2A 72 76 TWD 11S

+0.67 17 165 2A 72 77 TWD 05S

+0.54 15 166 2A 73 2

TWD 14S

+0.62 13 167 2A 73 27 TWD 10S

-0.08 18 168 2A 73 46 TWD 03S

-0.72 12 169 2A 73 76 TWD 05S

-0.34 18 170 2A 74 1

TWD 14S

+0.63 18 171 2A 74 68 SVI 04S

+11.32 44 172 2A 74 71 TWD 11S

+0.72 20 173 2A 74 72 TWD 10S

+0.60 15 174 2A 74 72 TWOD 10S

-0.69 16 175 2A 75 34 TWD 04S

+0.54 12 176 2A 75 59 TWD 01S

+0.66 8

177 2A 75 72 TWD 10S

+0.71 16 178 2A 75 72 TWD 11S

+0.69 16 179 2A 76 73 TWD 04S +0.62 10 180 2A 77 48 TWD 03S

+0.55 12 181 2A 77 68 TWD 02S

-0.41 15 182 2A 77 68 TWD 13S

+0.68 20 183 2A 77 72 TWD 10S

+0.75 21 184 2A 78 11 TWD

-07S

-0.69 11 185 2A 78 23 TWD 04S

-0.71 15 186 2A 78 67 SVI 06S

+16.95 49 187 2A 78 67 SVI 06S

+4.97 57 188 2A 78 67 TWD 15S

-0.46 15 189 2A 79 25 TWD 11S

-0.43 11 190 2A 79 33 SVI UTS

+5.33 27 191 2A 79 44 TWD 11S

+0.39 11 192 2A 79 73 SVI 04S

+12.05 37 193 2A 79 73 SVI 04S

+13.15 47 194 2A 80 61 SVI 07S

+0.13 0

195 2A 80 71 TWD 05S

+0.56 18 196 2A 80 73 SVI 04S +0.98 52 197 2A 80 73 TWOD 15S

-0.75 12 198 2A 81 33 TWD 09S

+0.67 19 199 2A 81 61 TWD 07S +0.47 7

200 2A 81 61 TWD 11S

-0.64 9

201

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 18 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 5: Location and Percent of Wall Thickness Penetration for Each Imperfection SG42:

'OTSG

,ROW, TUBE; IN",` ~-LOCATION' i%TW-VIndication' vN>

2A 81 73 SVI 04S

+11.93 59 202 2A 82 1

TWD 06S

-0.69 15 203 2A 82 1

TWD 13S

-0.59 14 204 2A 82 26 TWD 07S

-0.43 12 205 2A 82 30 SVI 08S

-0.18 23 206 2A 82 74 SVI 04S

+13.24 60 207 2A 83 73 MVI 04S

+9.68 47 208 2A 83 75 SVI 04S

-0.36 0

209 2A 84 4

MAA UTE

-0.21 N/A 210 2A 84 4

MVI UTE

-4.18 0

211 Post Re-roll Defect 2A 84 32 TWD 09S

+0.69 24 212 2A 84 73 SVI 04S

+11.83 42 213 2A 84 76 TWD 11S

+0.70 20 214 2A 85 31 TWD 09S

+0.68 19 215 2A 85 63 SVI 06S

+0.23 0

216 2A 85 69 MVI 04S

+10.16 58 217 2A 85 69 MVI 04S

+12.01 43 218 2A 85 69 SVI 04S

+7.90 43 219 2A 85 72 SVI 04S

+13.80 41 220 2A 85 122 TWD 09S

-0.24 8

221 2A 86 4

SM UTE

-0.27 N/A 222 2A 86 7

MM UTE

-0.25 N/A 223 2A 86 7

MVI UTE

-3.92 5

224 Post Re-roll Defect 2A 86 7

MVI UTE

-4.71 5

225 Post Re-roll Defect 2A 86 61 SVI 04S

+11.35 53 226 2A 86 61 SVI 04S

+12.72 30 227 2A 86 71 TWD 14S

+0.75 13 228 2A 86 75 TWD 11S

+0.63 20 229 2A 86 127 TWD 13S

+0.70 26 230 2A 86 127 TWD 14S

-0.61 24 231 2A 87 8

TWD 03S

+0.76 21 232 2A 87 9

SAA UTE

-0.27 N/A 233 2A 87 9

SVI UTE

-4.74 2

234 Post

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 19 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 5: Location and Percent of Wall Thickness Penetration for Each Imperfection SG42:

OTSG,ROW,

-TUBE.

IND

, 'LOCATION, %TW. Indication Count Re-roll Defect 2A 87 71 TWD 13S

+0.68 16 235 2A 87 92 SVI 05S

+0.17 0

236 2A 88 75 SVI 05S

-0.38 0

237 2A 89 8

SPA UTE

-0.22 N/A 238 2A 89 74 TWD 09S

+0.75 20 239 2A 89 75 TWD 10S

+0.75 18 240 2A 89 124 TWD 08S

+0.68 13 241 2A 89 124 TWD 08S

-0.42 16 242 2A 90 7

TWD 08S

-0.75 15 243 2A 90 62 SVI 05S

-0.16 0

244 2A 90 74 TWD 10S

+0.63 22 245 2A 91 3

TWD 09S

+0.21 9

246 2A 91 7

SPA UTE

-0.33 N/A 247 2A 91 7

MVI UTE

-3.59 12 248 Post Re-roll Defect 2A 91 8

SPA UTE

-0.21 N/A 249 2A 91 65 TWD 05S

-0.40 12 250 2A 91 74 TWD 05S

-0.49 9

251 2A 92 9

SMA UTE

-0.40 N/A 252 2A 92 127 TWD 08S

+0.49 7

253 2A 92 129 TWD 07S

-0.70 11 254 2A 93 48 TWD 05S

+0.00 18 255 2A 93 80 TWD 05S

-0.40 16 256 2A 93 89 SVI 05S

+0.00 11 257 2A 95 1

TWD 08S

-0.66 8

258 2A 95 6

SVI UTS

+9.30 45 259 2A 96 5

MAA UTE

-0.38 NIA 260 2A 97 13 SVI UTS

+8.44 40 261 2A 97 40 SVI 05S

+2.12 45 262 2A 98 127 TWD 13S

-0.71 16 263 2A 99 7

SPA UTE

-0.41 N/A 264 2A 99 92 SVI 06S

-0.13 0

265 2A 102 4

TWD 08S

-0.70 13 266 2A 104 93 TWD 07S

+0.44 12 267 2A 104 93 TWD 07S

-0.55 10 268 2A 104 104 SVI 07S

-0.28 23 269 2A 105 1

SCI 15S

+17.61 38 270 2A 106 22 SVI 05S

+13.29 57 271

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 20 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 5: Location and Percent of Wall Thickness Penetration for Each Imperfection SG-#2:

-OTSG ROW TUBE IND -,-LOCATION

%TW Indication Cou~nr-2A 106 38 TWD 05S

+0.67 12 272 2A 106 38 SVI 05S

+3.28 42 273 2A 106 119 SVI 15S

+17.73 32 274 2A 107 117 TWD 09S

+0.55 15 275 2A 107 117 TWD 09S

-0.52 9

276 2A 110 117 TWD 13S

-0.65 19 277 2A 113 4

TWD 14S

+0.53 18 278 2A 114 3

TWD 14S

+0.71 13 279 2A 114 40 TWD 06S

+0.20 16 280 2A 114 113 TWD 10S

+0.64 15 281 2A 114 113 TWD 10S

-0.63 13 282 2A 116 22 TWD 14S

-0.84 12 283 2A 116 104 MAA UTE

-0.25 N/A 284 2A 116 107 TWD 09S

-0.72 13 285 2A 116 110 TWO 09S

+0.62 8

286 2A 116 110 MMA UTE

-0.27 N/A 287 2A 116 111 TWD 08S

-0.50 10 288 2A 116 112 SMA UTE

-0.24 N/A 289 2A 117 64 SVI 05S

+3.14 30 290 2A 117 103 MAA UTE

-0.24 N/A 291 2A 117 108 SCI UTE

-0.27 57 292 2A 118 5

SVI 09S

-0.13 13 293 2A 118 104 TWD 09S

+0.75 12 294 2A 119 105 TWD 10S

+0.55 16 295 2A 119 105 TWD 10S

-0.68 8

296 2A 120 63 SVI 05S

+2.39 52 297 2A 120 63 SVI 05S

+2.63 40 298 2A 120 63 SVI 05S

+2.89 38 299 2A 120 102 TWD 09S

+0.67 15 300 2A 120 103 SMA UTE

-0.31 N/A 301 2A 120 104 TWD 10S

+0.50 21 302 2A 121 4

TWD 09S

+0.67 12 303 2A 122 101 TWD 04S

-0.70 11 304 2A 122 103 SPA UTE

-0.23 N/A 305 2A 122 104 TWD 10S

-0.62 12 306 2A 123 85 TWD 14S

-0.64 15 307 2A 123 101 TWD 10S

+0.63 6

308 2A 123 101 TWD 10S

-0.65 8

309 2A 123 102 TWD 10S

-0.59 16 310 2A 124 100 TWD 10S

-0.62 14 311 2A 124 101 TWD 10S

-0.66 12 312

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 21 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 5: Location and Percent of Wall Thickness Penetration for Each Imperfection SG-#2:

OTSG ROW,, TUBE,, `IND LOCATIONn

°%TW Indication e

i d

w.

Count 2A 125 79 MVI 05S

+15.01 57 313 2A 125 98 TWD 10S

-0.57 15 314 2A 125 100 TWD 10S

-0.67 14 315 2A 127 16 TWD 07S

-0.38 9

316 2A 127 69 SVI 05S

+6.25 54 317 2A 127 97 TWD 10S

-0.66 15 318 2A 128 5

TWD 10S

+0.63 23 319 2A 128 6

TWD 10S

+0.63 17 320 2A 128 7

TWD 10S

+0.63 18 321 2A 128 84 TWD 14S

-0.75 9

322 2A 129 5

TWD 10S

+0.63 14 323 2A 129 7

TWD 10S

+0.55 16 324 2A 129 8

TWD 10S

+0.68 17 325 2A 129 91 TWD 10S

+0.73 15 326 2A 129 93 TWD 13S

-0.66 13 327 2A 130 7

TWD 10S

+0.65 15 328 2A 130 8

TWD 10S

+0.61 18 329 2A 130 91 TWD 10S

+0.64 12 330 2A 131 7

TWD 10S

+0.57 21 331 2A 132 1

TWD 09S

+0.00 16 332 2A 132 8

TWD 10S

+0.64 13 333 2A 133 2

TWD 05S

-0.70 13 334 2A 133 3

TWD 10S

-0.62 18 335 2A 133 7

TWD 10S

+0.65 24 336 2A 133 80 TWD 14S

-0.73 18 337 2A 134 4

TWD 10S

+0.74 10 338 2A 134 5

TWD 10S

-0.71 14 339 2A 134 60 SVI 05S

-0.27 0

340 2A 135 21 SVI 05S

-0.27 7

341 2A 136 2

TWD 10S

-0.65 16 342 2A 136 4

TWD 10S

+0.69 14 343 2A 137 1

TWD 11S

-0.70 13 344 2A 137 6

TWD 103

+0.69 17 345 2A 137 6

TWD 10S

-0.66 15 346 2A 138 11 TWD 13S

-0.74 11 347 2A 139 14 TWD 04S

-0.64 21 348 2A 139 74 TWD 04S

-0.67 12 349 2A 140 1

TWD 10S

-0.73 13 350 2A 141 4

TWD 10S

+0.72 14 351 2A 141 36 SVI 04S

+0.02 23 352 2A 145 11 TWD 04S

-0.66 15 353

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 22 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 5: Location and Percent of Wall Thickness Penetration for Each Imperfection SG-#2:

OTSG ROW

'TUBEf

'IND'

.LOCATION,.

i%TWu Indication

\\,>,*>..,+, irs-tbM--,^tit.t;ount) 2A 145 54 TWD 13S

+0.70 14 354 2A 146 18 TWD 13S

-0.74 15 355 2A 146 31 TWD 10S

+0.72 22 356 2A 146 32 TWD 10S

+0.65 15 357 2A 146 33 TWD 10S

+0.74 23 358 2A 146 34 TWD 10S

+0.60 22 359 2A 146 36 TWD 10S

+0.65 12 360 2A 146 37 TWD 04S

-0.75 13 361 2A 146 37 TWD 10S

+0.67 20 362 2A 147 30 TWD 10S

+0.70 14 363 2A 147 34 TWD 10S

+0.73 18 364 2A 147 36 TWD 10S

+0.69 30 365 2A 147 46 TWD 14S

+0.67 18 366 2A 148 3

TWD 10S

+0.64 16 367 2A 148 3

TWD 10S

-0.66 11 368 2A 148 27 TWD 10S

-0.68 13 369 2A 148 28 TWD 10S

-0.66 11 370 2A 148 29 TWD 10S

+0.63 14 371 2A 148 30 TWD 10S

+0.74 15 372 2A 148 30 TWD 10S

-0.63 21 373 2A 148 31 TWD 10S

-0.66 13 374 2A 148 32 TWD 10S

+0.64 18 375 2A 149 18 TWD 10S

+0.62 11 376 2A 149 26 TWD 10S

+0.67 18 377 2A 149 26 TWD 10S

-0.70 16 378 2A 149 27 TWD 10S

+0.65 16 379 2A 149 27 TWD 10S

-0.72 18 380 2A 149 28 TWD 10S

+0.66 16 381 2A 149 28 TWD 10S

-0.68 15 382 2A 149 29 TWD 10S

-0.68 13 383 2A 149 31 TWD 10S

+0.66 14 384 2A 150 8

TWD 10S

+0.70 12 385 2A 150 13 TWD 10S

+0.74 12 386 2A 150 19 TWD 10S

+0.62 14 387 2A 150 19 TWD 10S -0.63 15 388 2A 150 20 TWD 10S

+0.67 15 389 2A 150 20 TWD 105

-0.60 15 390 2A 150 21 TWD 10S

+0.63 21 391 2A 150 21 TWD 10S

-0.61 20 392 2A 150 25 TWD 10S

+0.59 18 393 2A 150 25 TWD 10S

-0.68 22 394

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 23 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 5: Location and Percent of Wall Thickness Penetration for Each Imperfection SG42:

'OTSG ROW.,TUBE.- 'IND

'-, LOCATION

%TW Indication

Count, 2A 150 27 TWD 1OS

-0.66 29 395 2A 151 1

TWlD 1OS

+0.50 15 396 2A 151 4

SAI 15S

+6.04 1

397 2A 151 4

SAI 15S

+7.01 44 398 2A 151 5

TWD 06S

-0.49 5

399 2A 151 11 SAI 15S

+5.10 1

400 2A 151 13 TWlD 10S

+0.70 19 401 2A 151 13 TWlD 1OS

-0.69 17 402 2A 151 15 TWVD 10S

+0.67 11 403 2A 151 15 TWD 10S

-0.73 18 404 2A 151 15 TWD 13S

+0.65 7

405 2A 151 15 TWD 13S

-0.66 15 406 2A 151 16 TWD 1OS

-0.73 15 407

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 24 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 6! Identification of Tubes Renaired-SG #2 SIG j ROW I TUBE Reason for Repair Tube Count Repaired By Plugging 2-A 5

15 Capture Tube A 6-18 1

2-A 5

16 Capture Tube A 6-18 2

2-A 6

17 Capture Tube A 6-18 3

2-A 6

19 Capture Tube A 6-18 4

2-A 7

19 Capture Tube A 6-18 5

2-A 7

20 Capture Tube A 6-18 6

2-A 7

52 Capture Tube A-6-51 7

2-A 12 39 SVI In Reroll/Failed Reroll 8

2-A 16 25 Capture Tube A 17-26 9

2-A 17 25 Capture Tube A 17-26 10 2-A 32 51 Capture Tube A 33-52 11 2-A 32 52 Capture Tube A 33-52 12 2-A 33 51 Capture Tube A 33-52 13 2-A 33 53 Capture Tube A 33-52 14 2-A 34 51 Capture Tube A 33-52 15 2-A 34 52 Capture Tube A 33-52 16 2-A 42 67 SVI @ 06S -0.19 17 2-A 44 117 SVI @ 08S -0.01 18 2-A 46 2

Capture Tube A 47-2 19 2-A 47 3

Capture Tube A 47-2 20 2-A 48 2

Capture Tube A 47 21 2-A 48 3

Capture Tube A 47-2 22 2-A 49 87 Capture Tube A 50-87 23 2-A 49 88 Capture Tube A 50-87 24 2-A 50 86 Capture Tube A 50-87 25 2-A 50 88 Capture Tube A 50-87 26 2-A 51 87 Capture Tube A 50-87 27 2-A 51 88 Capture Tube A 50-87 28 2-A 52 66 SVI @ 05S +0.29 29 2-A 62 2

MVI In Reroll/Failed Reroll 30 2-A 64 29 Capture Tube A 65-29 31 2-A 64 30 Capture Tube A 65-29 32 2-A 64 51 SVI @ 04S +16.69 33 2-A 65 28 Capture Tube A 65-29 34 2-A 65 30 Capture Tube A 65-29 35 2-A 65 70 SVI @ 04S +9.16 36 SVI @ 04S +8.59 SVI _ 04S +7.34 2-A 65 73 SVI @ 04S +5.14 37 2-A 66 29 Capture Tube A 65-29 38

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 25 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Tabhi A-Idichntifirctinn nf Tiuhb Renairpd-SG #2 S/G ROW TUBE Reason for Repair Tube Count 2-A 66 30 Capture Tube A 65-29 39 2-A 66 61 SVI @ 04S +13.58 40 2-A 66 68 SAI @ 04S +5.76 41 2-A 67 52 SVI @ 04S +1 6.13 42 2-A 67 67 SVI @ 04S +10.12 43 2-A 68 3

SVI In Reroll/Failed Reroll 44 2-A 68 51 SVI @ 04S +17.87 45 SVI @ 04S +14.04 2-A 70 63 SVI @ 04S +3.40 46 2-A 71 65 SVI @ 06S +14.25 47 SVI @ 06S +12.87 SVI @ 06S +15.97 SVI @ 06S +13.73 2-A 71 66 SVI @ 03S +0.44 48 2-A 71 72 SVI @ 04S +2.49 49 SVI @ 04S +3.12 SVI @ 04S +4.70 SVI @ 04S +1.51 2-A 74 68 SVI @ 04S +11.32 50 2-A 78 67 SVI @ 06S +16.95 51 SVI @ 06S +4.97 2-A 79 33 SVI @ UTS +5.33 52 2-A 79 73 SVI @ 04S +1 3.15 53 SVI @ 04S +12.05 2-A 80 61 SVI @ 07S +0.13 54 2-A 80 73 SVI @ 04S +0.98 55 2-A 81 73 SVI @ 04S +11.93 56 2-A 82 30 SVI @ 08S-0.18 57 2-A 82 74 SVI @ 04S +13.24 58 2-A 83 73 MVI @ 04S +9.68 59 2-A 83 75 SVI @ 04S -0.36 60 2-A 84 4

MVI In Reroll/Failed Reroll 61 2-A 84 73 SVI @ 04S +11.83 62 2-A 85 63 SVI @ 06S +0.23 63 2-A 85 69 MVI @ 04S +10.16 64 MVI @ 04S +12.01 SVI @ 04S +7.90 2-A 85 72 SVI @ 04S +13.8 65 2-A 86 7

MVI In Reroll 66 2-A 86 8

Preventative / Noisy Data 67 2-A 86 61 SVI @ 04S +12.72 68 SVI @ 04S +11.35 2-A 87 9

SVI In Reroll/Failed Reroll 69

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 26 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 6: Identification of Tubes Reoaired-SG #2 SIG ROW TUBE Reason for Repair Tube Count 2-A 87 92 SVI @ 05S +0.17 70 2-A 88 75 SVI @ 05S -0.38 71 2-A 89 19 Capture Tube A 90-19 72 2-A 89 20 Capture Tube A 90-19 73 2-A 90 18 Capture Tube A 90-19 74 2-A 90 20 Capture Tube A 90-19 75 2-A 90 62 SVI @ 05S -0.16 76 2-A 91 7

MVI In Reroll/Failed Reroll 77 2-A 91 18 Capture Tube A 90-19 78 2-A 91 19 Capture Tube A 90-19 79 2-A 93 89 SVI @ 05S +0.00 80 2-A 95 6

SVI @ UTS +9.3 81 2-A 97 13 SVI @ UTS +8.44 82 2-A 97 40 SVI @ 05S +2.12 83 2-A 99 92 SVI @ 06S -0.13 84 2-A 101 115 Capture Tube A 102-115 85 2-A 101 116 Capture Tube A 102-115 86 2-A 102 114 Capture Tube A 102-115 87 2-A 102 116 Capture Tube A 102-115 88 2-A 103 115 Capture Tube A 102-115 89 2-A 103 116 Capture Tube A 102-115 90 2-A 104 104 SVI @ 07S -0.28 91 2-A 105 1

SCI @ 15S +17.61 92 2-A 106 22 SVI @ 05S +13.29 93 2-A 106 38 SVI @ 05S +3.28 94 2-A 106 119 SVI @ 15S +17.73 95 2-A 108 67 Capture Tube A 109-67 96 2-A 108 68 Capture Tube A 109-67 97 2-A 109 66 Capture Tube A 109-67 98 2-A 109 68 Capture Tube A 109-67 99 2-A 110 66 Capture Tube A 109-67 100 2-A 110 67 Capture Tube A 109-67 101 2-A 117 64 SVI @ 05S +3.14 102 2-A 118 5

SVI @ 09S -0.13 103 2-A 120 63 SVI @ 05S +2.89 104 SVI @ 05S +2.63 SVI @ 05S +2.39 2-A 121 21 Capture Tube A 122-21 105 2-A 121 22 Capture Tube A 122-21 106 2-A 122 20 Capture Tube A 122-21 107 2-A 122 22 Capture Tube A 122-21 108 2-A 123 20 Capture Tube A 122-21 109 2-A 123 21 Capture Tube A 122-21 110

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 27 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Thiknl A. Ifrnfifir*inn nfTiihp RPnzaired-SG f2 SIG ROW TUBE Reason for Repair Tube Count 2-A 123 81 Capture Tube A 124-79 111 2-A 124 80 Capture Tube A 124-79 112 2-A 125 78 Capture Tube A 124-79 113 2-A 125 79 MVI@05S +15.01 114 2-A 127 69 SVI @ 05S +6.25 115 2-A 134 60 SVI @ 05S -0.27 116 2-A 135 21 SVI @ 05S-0.27 117 2-A 139 61 Capture Tube A 140-60 118 2-A 139 62 Capture Tube A 140-60 119 2-A 140 59 Capture Tube A 140-60 120 2-A 140 61 Capture Tube A 140-60 121 2-A 141 36 SVI @ 04S +0.02 122 2-A 141 58 Capture Tube A 140-60 123 2-A 141 59 Capture Tube A 140-60 124 2-A 151 4

SAI @ 15S +7.00 125 SAI @ 15S +6.04 2-A 151 11 SAI @ 15S +5.10 126 Repaired By Reroll 2-A 14 10 SAA@ UTE-0.3 1

2-A 15 10 MAA UTE -0.32 2

2-A 15 70 SAA@UTE -0.33 3

2-A 18 13 MAA@ UTE -0.28 4

2-A 18 14 MAA@UTE-0.16 5

2-A 21 16 SA@ UTE -0.14 6

2-A 21 76 MAA@ UTE -0.2 7

2-A 21 77 SAA@UTE -0.34 8

2-A 27 21 SAA@UTE -0.3 9

2-A 27 65 SAA@UTE -0.28 10 2-A 30 23 MAA @ UTE -0.29 11 2-A 45 120 SCI @ UTE -0.32 12 2-A 46 116 SAA@ UTE -0.28 13 2-A 63 1

SCI @ UTE -0.27 14 2-A 63 3

MAA@UTE -0.23 15 2-A 63 78 SAI @ UTE-1.22 16 2-A 65 1

SAA@UTE -0.24 17 2-A 66 1

SAA UTE -0.26 18 2-A 68 4

SA@ UTE -0.25 19 2-A 86 4

SM @ UTE -0.27 20 2-A 89 8

SM @ UTE -0.22 21 2-A 91 8 -

SAA@ UTE -0.21 22 2-A 92 9

SAA@ UTE -0.4 23 2-A 96 5

MM @ UTE -0.38 24

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 28 TECHNICAL SPECIFICATION REPORTING REQUIREMENTS Table 6: Identification of Tubes Repaired-SG #2 S/G ROW TUBE Reason for Repair Tube Count 2-A 99 7

SAA @ UTE -0.41 25 2-A 116 104 MAA @ UTE-0.25 26 2-A 116 110 MAA @ UTE-0.27 27 2-A 116 112 SAA @ UTE -0.24 28 2-A 117 103 MAA @ UTE-0.24 29 2-A 117 108 SCI@ UTE-0.27 30 2-A 120 103 SAA @ UTE-0.31 31 2-A 122 103 SAA @ UTE-0.23 32 Totals 158

I f Docket Number 50-346 License Number NPF-3 Serial Number 2944 Page 1 EDDY CURRENT IDENTIFICATION CODES The following identification codes were used in Attachment 1.

LTE Lower Tube End LTS Lower Tube Sheet MAA Multiple Axial Tube-end Anomaly MAI Multiple Axial Indication MVI Multiple Volumetric Indications SAA Single Axial Tube-end Anomaly SAI Single Axial Indication SCI Single Circumferential Indication SVI Single Volumetric Indication TWD Percent Through Wall Degradation (Assigned to Wear Indications)

UTE Upper Tube End UTS Upper Tube Sheet xxS Support Plate Number

Docket Number 50-346 License Number NPF-3 Serial Number 2944 Enclosure COMMITMENT LIST The following list identifies those actions committed to by the Davis-Besse Nuclear Power Station (DBNPS) in this document. Any other actions discussed in the submittal represent intended or planned actions by the DBNPS.

They are described only as information and are not regulatory commitments. Please notify the Manager -

Regulatory Affairs (419-321-8450) at the DBNPS of any questions regarding this document or associated regulatory commitments.

COMMITMENTS DUE DATE None N/A