Text
Mar.
17, 2003 Page 1
of 1 MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2003-12590 USER INFORMATION!
GERLACH*
OS M
EMPL#:28401 CA#:
0363 Address:
N CSA2 Phone#:
2 4-94 TRANSMIT AL INFORMATION:
TO:
CgR-1A M
03/17/2003 LOCATION:
rUSNRCZI FROM:
NUCEEAR-"RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)
'HE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY
ýR ELECTRONIC MANUAL ASSIGNED TO YOU:
ITSBI -
IMPROVED TECHNICAL SPECIFICATIONS MANUAL BASES UNIT 1
REMOVE MANUAL TABLE OF CONTENTS DATE:
02/05/2003 ADD MANUAL TABLE OF CONTENTS DATE:
03/14/2003 CATEGORY:
DOCUMENTS TYPE:
ITSB1 ID:
ITSB1 REMOVE:
REV:38 ADD:
REV:
39 UPDATES FOR HARD COPY MANUALS WILL BE DISTRIBUTED WITHIN 5 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.
PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON RECEIPT OF HARD COPY.
FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.
TSB APPROVED AMENDMENT TO THE UNIT I TECHNICAL SPECIFICATIONS BASES MANUAL REVISION 39 Replace the following pages of the Technical Specifications Bases Manual with the enclosed pages. The revised pages are identified by Revision Number and contain vertical lines indicating the area of change.
g.*Jic docs\\ts-wp51lts-manual\\0.00 lists~tsb-rem ins u 1 u2 doc 3/6/03 REMOVE PAGES INSERT PAGES REV. #
TS / B LOES 1 through TS / B LOES 5 TS / B LOES 1 through TS / B LOES 5 39 B 3.0-8 and B 3.0-9 TS / B 3.0-8 and TS / B 3 0-9 1
- 1-
- 1-
+
+
+
+
+
+
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Table of Contents SAFETY LIMITS BASES Page B 2.0-1 Page TS/B 2.0-2 Pages TS/B 2.0-3 through TSB 2.0-5 Page TS/B 2.0-6 Pages B 2.0-7 through B 2.0-9 LCO AND SR APPLICABILITY BASES Pages B 3.0-1 through B 3.0-7 Pages TS / B 3.0-8 and TS / B 3.0-9 "Page B 3.0-10 through B 3.0-12 Pages TS / B 3.0-13 through TS / B 3.0-15 K
REACTIVITY CONTROL BASES
\\
x Pages B 3.1-1 through B 3.1-51 POWER DISTRIBUTION LIMITS BA,,SES S
Page B 3.2-1 Page TS/B 3.2-2 4
Page B 3.2-3 Pages TS/B 3.2-4 through TSIB 3.2-6 Pages B 3.2-7 and B 3.2-8, Page TS/B 3.2-9 Page B 3.2-10,
Page TS/B 3.2-11, Page B 31.2$ýi<
Page TS/B 3.2-13.
Pages"B 3.2-14arid B 3.2-15 Page rS/B 3.2-16 PagesB 3.2'-17 and 3.2-18 Page TS/B' 3.2-19 INSTRUMENTATION Pages TS / B 3.3-1 through TS I B 3.3-10 Page TS / B 3.3-11 Pages TS / B 3.3-12 through TS / B 3.3-27 Pages TS / B 3.3-28 through TS / B 3.3-31 Pages TS / B 3.3-32 and TS I B 3.3-33 Pages TS / B 3.3-34 through TS / B 3.3-54 Pages B 3.3-55 through B 3.3-63 Pages TS / B 3.3-64 and TS / B 3.3-65 Page TS / B 3.3-66 Page TS / B 3.3-67 Page TS / B 3.3-68 Revision I
0 c
1 corrected 0
/
/
0 1
0 1
0 SUSQUEHANNA - UNIT 1 TOC B 2.0 B 3.0 B 3.1 B 3.2 B 3.3 TS / B LOES-1 Revision 39
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision Corrected Pages TS / B 3.3-69 through TS I B 3.3-75 2
Page TS I B 3.3-75a 4
Pages TS / B 3.3-75b through TS / B 3.3-75c 3
Pages B 3.3-76 through B 3.3-103 0
Page TS / B 3.3-104 1
Pages B 3.3-105 and B 3.3-106 0
Page TS / B 3.3-107 1
Page B 3.3-108 0
Page TS / B 3.3-109 1
Pages B 3.3-110 and B 3.3-111 0
Pages TS/B 3.3-112 and TS/B 3.3-112a 1
Pages B 3.3-113 and B 3.3-114 0
Page TS / B 3.3-115 1
Page TS / B 3.3-116 2
Page TS / B 3.3-117 1
Pages B 3.3-118 through B 3.3-122 0
Pages TS / B 3.3-123 through TS / B 3.3-124 1
Page TS / B 3.3-124a 0
Pages B 3.3-125 and B 3.3-126 0
Page TS / B 3.3-127 1
Pages B 3.3-128 through B 3.3-130 0
Page TS / B 3.3-131 1
Pages B 3.3-132 through B 3.3-137 0
Page TS / B 3.3-138 1
Pages B 3.3-139 through B 3.3-162 0
Page TS / B 3.3-163 1
Pages B 3.3-164 through B 3.3-177 0
Pages B 3.3-178 and B 3.3-179 1
Page B 3.3-179a 0
Pages TS / B 3.3-180 through TS / B 3.3-191 1
Pages B 3.3-192 through B 3.3-219 0
B 3.4 REACTOR COOLANT SYSTEM BASES Pages B 3.4-1 and B 3.4-2 0
Pages TS/B 3.4-3 and TS/B 3.4-4 1
Pages B 3.4-5 through B 3.4-14 0
Page TS / B 3.4-15 1
Pages TS / B 3.4-16 and TS / B 3.4-17 2
Page TS / B 3.4-18 1
Pages B 3.4-19 through B 3.4-28 0
Page TS / B 3.4-29 1
Pages B 3.4-30 through B 3.4-48 0
Page TS / B 3.4-49 2
Page TS / B 3.4-50 1
Page TS / B 3.4-51 2
Pages TS / B 3.4-52 and TS / B 3.4-53 1
SUSQUEHANNA-UNIT 1 Revision 39 TS / B LOES-2
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision Page TS / B 3.4-54 2
Page TS / B 3.4-55 2
Page TS / B 3.4-56 1
Page TS / B 3.4-57 2
Pages TS / B 3.4-58 through TS I B 3.4-60 1
B 3.5 ECCS AND RCIC BASES Pages B 3.5-1 and B 3.5-2 0
Page TS / B 3.5-3 2
Pages B 3.5-4 through B 3.5-10 0
Page TS / B 3.5-11 1
Pages B 3.5-12 through B 3.5-15 0
Pages TS / B 3.5-16 through TS / B 3.5-18 1
Pages 8 3.5-19 through B 3.5-24 0
Page TS / B 3.5-25 1
Pages B 3.5-26 through B 3.5-31 0
B 3.6 CONTAINMENT SYSTEMS BASES Page TS / B 3.6-1 2
Page TS / B 3.6-1a 3
Pages TS / B 3.6-2 through TS / B 3.6-5 2
Page TS / B 3.6-6 3
Pages TS / B 3.6-6a and TS / B 3.6-6b 2
Page TS / B 3.6-6c 0
Pages B 3.6-7 through B 3.6-14 0
Page TS / B 3.6-15 2
Pages TS / B 3.6-15a and TS / B 3.6-15b 0
Page B 3.6-16 0
Page TS / B 3.6-17 1
Page TS / B 3.6-17a 0
Pages TS / B 3.6-18 and TS I B 3.6-19 0
Page TS / B 3.6-20 1
Page TS / B 3.6-21 2
Page TS / B 3.6-22 1
Page TS / B 3.6-22a 0
Page TS / B 3.6-23 1
Pages TS / B 3.6-24 through TS I B 3.6-25 0
Page TS / B 3.6-26 0
Corrected Page TS / B 3.6-27 2
Page TS / B 3.6-28 4
Page TS / B 3.6-29 1
Page TS/B 3.6-30 1
Page TS / B 3.6-31 3
Pages B 3.6-32 through B 3.6-35 0
Page TS / B 3.6-36 1
Page B 3.6-37 0
SUSQUEHANNA - UNIT 1 Revision 39 TS / B LOES-3
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision Page TS/B 3.6-38 1
Page B 3.6-39 0
Page TS / B 3.6-40 2
Pages B 3.6-41 through B 3.6-43 0
Pages TS / B 3.6-44 through TS / B 3.6-51 1
Page TS / B 3.6-52 2
Pages B 3.6-53 through B 3.6-83 0
Pages TS / B 3.6-84 2
Pages TS I B 3.6-85 through TS / B 3.6-88 1
Page TS / B 3.6-88a 1
Pages TS / B 3.6-89 through TS / B 3.6-100 1
Pages B 3.6-101 through B 3.6-107 0
B 3.7 PLANT SYSTEMS BASES Pages TS / B 3.7-1 through TS / B 3.7-6 2
Page TS / B 3.7-6a 2
Pages TS / 13 3.7-6b and TS / B 3.7-6c 0
Pages TS I B 3.7-7 through TS / B 3.7-11 1
Pages TS I B 3.7-12 and TS / B 3.7-13 1
Pages TS / B 3.7-14 through TS / B 3.7-18 2
Page TS / B 3.7-18a 0
Pages TS / B 3.7-19 through TS / B 3.7-23 1
Pages B 3.7-24 through B 3.7-26 0
Pages TS / B 3.7-27 through TS / B 3.7-29 2
Page TS / B 3.7-30 1
Pages B 3.7-31 through B 3.7-33 0
B 3.8 ELECTRICAL POWER SYSTEMS BASES Pages TS I B 3.8-1 through TS / B 3.8-4 2
Page TS / B 3.8-5 3
Pages TS / B 3.8-6 through TS/B 3.8-17 2
Page TS / B 3.8-18 3
Pages TS / B 3.8-19 through TS / B 3.8-21 2
Pages TS / B 3.8-22 and TS / B 3.8-23 3
Pages TS / B 3.8-24 through TS / B 3.8-37 2
Pages B 3.8-38 through B 3.8-53 0
Pages TS / B 3.8-54 through TS / B 3.8-61 1
Page TS I B 3.8-62 2
Page TS / B 3.8-63 2
Page TS I B 3.8-64 1
Page TS / B 3.8-65 2
Pages TSIB 3.8-66 through B 3.8-90 0
B 3.9 REFUELING OPERATIONS BASES Pages TS I B 3.9-1 and TS / B 3.9-1a 1
Pages TS I B 3.9-2 through TS / B 3.9-4 1
Pages B 3.9-5 through B 3.9-30 0
SUSQUEHANNA - UNIT 1 TS / B LOES--4 Revision 39
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision B 3.10 SPECIAL OPERATIONS BASES Page TS I B 3.10-1 1
Pages B 3.10-2 through B 3.10-38 0
SUSQUEHANNA-UNIT 1 TS / B LOES-5 Revision 39
PPL Rev. 0 LCO APPLICABILITY B 3.0 BASES LCO 3.0.6 entry into multiple support and supported systems' LCOs' Conditions and (continued)
Required Actions are eliminated by providing all the actions that are necessary to ensure the plant is maintained in a safe condition in the support system's Required Actions.
However, there are instances where a support system's Required Action may either direct a supported system to be declared inoperable or direct entry into Conditions and Required Actions for the supported system. This may occur immediately or after some specified delay to perform some other Required Action. Regardless of whether it is immediate or after some delay, when a support system's Required Action directs a supported system to be declared inoperable or directs entry into Conditions and Required Actions for a supported system, the applicable Conditions and Required Actions shall be entered in accordance with LCO 3.0.2.
Specification 5.5.11, "Safety Function Determination Program (SFDP),"
ensures loss of safety function is detected and appropriate actions are taken.
Upon entry into LCO 3.0.6, an evaluation shall be made to determine if loss of safety function exists. Additionally, other limitations, remedial actions, or compensatory actions may be identified as a result of the support system inoperability and corresponding exception to entering supported system Conditions and Required Actions. The SFDP implements the requirements of LCO 3.0.6.
Cross division checks to identify a loss of safety function for those support systems that support safety systems are required. The cross division check verifies that the supported systems of the redundant OPERABLE support system are OPERABLE, thereby ensuring safety function is retained. If this evaluation determines that a loss of safety function exists, the appropriate Conditions and Required Actions of the LCO in which the loss of safety function exists are required to be entered.
This loss of safety function does not require the assumption of additional single failures or loss of offsite power or concurrent loss of emergency diesel generators. Since operation is being restricted in accordance with the ACTIONS of the support system, any resulting temporary loss of redundancy or single failure protection is taken into account. Similarly, the ACTIONS for inoperable offsite circuit(s) and inoperable diesel generator(s) provide the necessary restriction for cross train inoperabilities. This explicit cross train verification for inoperable AC electrical power sources also acknowledges that supported system(s) are not declared inoperable solely as a result of inoperability of a normal or emergency electrical power source (refer to the definition of OPERABILITY).
(continued)
SUSQUEHANNA-UNIT 1 TS / B 3.0-8 Revision 1
PPL Rev. 0 LCO APPLICABILITY B 3.0 BASES LCO 3.0.6 (continued LCO 3.0.7 When a loss of safety function is determined to exist, and the SFDP requires entry into the appropriate Conditions and Required Actions of the LCO in which the loss of safety function exists, consideration must be given to the specific type of function affected. Where a loss of safety function is solely due to a single TS support system (e.g., loss of automatic start due to inoperable instrumentation, or loss of pump suction source due to low tank level) the appropriate LCO is the LCO for the support system. The ACTIONS for a support system LCO adequately addresses the inoperabilities of that system without reliance on entering its supported system LCO. When the loss of function is the result of multiple support systems, the appropriate LCO is the LCO for the supported system.
There are certain special tests and operations required to be performed at various times over the life of the unit. These special tests and operations are necessary to demonstrate select unit performance characteristics, to perform special maintenance activities, and to perform special evolutions.
Special Operations LCOs in Section 3.10 allow specified TS requirements to be changed to permit performances of these special tests and operations, which otherwise could not be performed if required to comply with the requirements of these TS. Unless otherwise specified, all the other TS requirements remain unchanged. This will ensure all appropriate requirements of the MODE or other specified condition not directly associated with or required to be changed to perform the special test or operation will remain in effect.
The Applicability of a Special Operations LCO represents a condition not necessarily in compliance with the normal requirements of the TS. Compliance with Special Operations LCOs is optional. A special operation may be performed either under the provisions of the appropriate Special Operations LCO or under the other applicable TS requirements. If it is desired to perform the special operation under the provisions of the Special Operations LCO, the requirements of the Special Operations LCO shall be followed. When a Special Operations LCO requires another LCO to be met, only the requirements of the LCO statement are required to be met regardless of that LCO's Applicability (i.e., should the requirements of this other LCO not be met, the ACTIONS of the Special Operations LCO apply, not the ACTIONS of the other LCO). However, there are instances where the Special Operations LCO ACTIONS may direct the other LCOs' ACTIONS be met. The Surveillances of the other LCO are not required to be met, unless specified in the Special Operations LCO. If conditions exist such that the Applicability of any other LCO is met, all the other LCO's requirements (ACTIONS and SRs) are required to be met concurrent with the requirements of the Special Operations LCO.
SUSQUEHANNA-UNIT 1 TS / B 3.0-9 Revision 1