Text
Nuclear Operating Company South TxAs Procct Elecinc Generati$ Station PO Box 2839 Wadsw orth. Texas 77483 March 5, 2003 NOC-AE-03001480 10CFR50.55a U. S. Nuclear Regulatory Commission Attention: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852 South Texas Project Unit 2 Docket No. STN 50-499 Preservice Inspection Summary Report for Tubing in Replacement Steam Generators - 2RE09 Enclosed are four copies of the "Preservice Inspection Summary Report for Tubing in the Replacement Steam Generators of the South Texas Project Electric Generating Station, Unit 2."
The steam generators were replaced during the ninth refueling outage (2RE09) completed on December 6, 2002. The summary report satisfies the reporting requirements of ASME Section XI, Article IWA-6230, and Sections 4.4.5.5(b) and 6.9.2 of the South Texas Project Technical Specifications.
If there are any questions regarding this report, please contact Mr. Jim Haning at (361) 972-8983 or me at (361) 972-7786.
Alex P. Kent
- Manager, Test/Program Engineering jtc
Enclosure:
Preservice Inspection Summary Report for Tubing in the Replacement Steam
Ž'tza (.y Generators of the South Texas Project Electric Generating Station, Unit 2
.eetaruocdeq lh, o
STI: 31568901 AOcI-7
NOC-AE-03001480 Page 2 of 2 cc: w/o attachment except *
(paper copy)
- Ellis W. Merschoff Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, Texas 76011-8064 U. S. Nuclear Regulatory Commission Attention: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852 Richard A. Ratliff Bureau of Radiation Control Texas Department of Health 1100 West 49th Street Austin, TX 78756-3189 Cornelius F. O'Keefe U. S. Nuclear Regulatory Commission P. 0. Box 289, Mail Code: MNl 16 Wadsworth, TX 77483 (electronic copy)
A. H. Gutterman, Esquire Morgan, Lewis & Bockius LLP L. D. Blaylock/W. C. Gunst City Public Service Mohan C. Thadani U. S. Nuclear Regulatory Commission R. L. Balcom Texas Genco, LP A. Ramirez City of Austin C. A. Johnson AEP Texas Central Company Jon C. Wood Matthews & Branscomb C. M. Canady City of Austin Electric Utility Department 721 Barton Springs Road Austin, TX 78704
PRESERVICE INSPECTION
SUMMARY
REPORT FOR TUBING IN THE REPLACEMENT STEAM GENERATORS of the SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION UNIT 2 P.O. BOX 289 WADSWORTH, TEXAS 77483 Owner: South Texas Project Nuclear Operating Company Commercial Operation:
June 19, 1989 Issue Date:
February 2003
PRESERVICE INSPECTION
SUMMARY
REPORT FOR TUBING IN THE REPLACEMENT STEAM GENERATORS of the SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION UNIT 2 USNRC DOCKET NO.:
50-499 OPERATING LICENSE NO.:
NPF-80 COMMERCIAL OPERATION DATE: June 19, 1989 T.J Haning Senior Consulting Engir I
I Date Approved By:
M.uS. Lastlen9
/Date Supervisor --Test Engineering Prepared By:
TABLE OF CONTENTS Page No.
1 1.0 Introduction 2.0 Scope of Examinations 3.0 Personnel, Procedures and Equipment 3.1 Personnel Qualifications 3.2 Examinations and Analysis Procedures 3.3 Equipment 3.4 Calibration Standards 4.0 Summary of Examinations 5.0 Examination Results and Corrective Actions 5.1 Steam Generator A 5.2 Steam Generator B 5.3 Steam Generator C 5.4 Steam Generator D 6.0 Certification of Inspections Appendix A Appendix B Appendix C Appendix D Appendix E Appendix F List of Certified Personnel Tubes Examined by MRPC Dings and Dents Tubes with Other Anomalous Signals Tubes Removed from Service Prior to Operation Owner's Report for Inservice Inspections - NIS-1 Form iii 2
4 4
4 5
5 6
7 8
8 8
9 10
STEAM GENERATOR TUBE EXAMINATIONS 1.0 Introduction This summary report describes the preservice inspection (PSI) of the tubing of the South Texas Project Electric Generating Station, Unit 2 (STPEGS-2) replacement steam generators. This PSI was performed by Westinghouse Electric Company, LLC., the examination agency, in the Equipos Nucleares, S.A.
(ENSA) manufacturing facility in Maliano, Cantabria, Spain. The PSI was performed after their hydrostatic testing and just prior to shipment to the STPEGS-2.
The steam generator PSI is required by Sections 3/4.4.5 and 4.0.5 of the Technical Specifications to be performed in accordance with the edition and addenda of the American Society of Mechanical Engineers (ASME)Section XI Code "Inservice Inspection of Nuclear Power Plant Components" prescribed by Title 10 of the Code of Federal Regulations, Part 50, Section 50.55a(g). Therefore, the PSI is required to meet the 1989 Edition of the ASME Code Section XI.
The PSI of replacement steam generator tubing commenced on January 10, 2002. The eddy current examinations that constitute the PSI were completed on February 2, 2002. However, the PSI was not considered to be complete until the breakers closed after installation of the steam generators when the potential of events (e.g.; loose parts, transportation damage, etc.) necessitating further baseline examination had passed. The PSI was performed during the second inservice inspection interval of the STPEGS-2 that started October 19, 2000 and is expected to end October 18, 2010.
The STPEGS-2 plant design contains four (4) Westinghouse recirculating design steam generators designated as model Delta 94 (D94). Each model D94 generator was fabricated by ENSA in Spain. Each steam generator contains 7585 tubes. The tubing material is thermally treated Inconel Alloy 690 (single pilgered) having a nominal outer diameter (OD) of 0.688 inch and nominal wall thickness of 0.040 inch.
The nominal thickness of the tubesheet is 25.43 inches.
1
2.0 Scope of Examinations The "Inservice Inspection Program Plan for the Second Interval of the South Texas Project Electric Generating Station, Units 1 and 2, Steam Generator Tubing" describes the inservice inspection program for steam generator tubing. An auxiliary PSI outage plan entitled, "Outage Plan for the Preservice Inspection of Steam Generator Tubing in the South Texas Project Electric Generating Station, Unit 2, Replacement Steam Generators", including Change Number 001, was prepared by Westinghouse and approved by STP Nuclear Operating Company (STPNOC). The PSI outage plan identified the steam generator tube areas to be examined by eddy current testing (ET) and the ET procedures expected to be used during the PSI.
A degradation assessment (DA) was prepared by Westinghouse and approved by STPNOC prior to the inspection. This document is STPNOC condition report action number 01-19514-3 and identifies necessary examination techniques to be used. An evaluation of these techniques was performed to ensure their adequate qualification. In addition, a site-appropriateness review was conducted to ensure that each technique could be used in the STPNOC Unit 2 replacement steam generators. All techniques were reviewed for use by the Westinghouse senior level rI-certified qualified data analyst (QDA), the STPNOC inservice inspection engineer, and the STPNOC QDA.
The nomenclature used to identify these steam generators is as follows:
Steam Generator Name Manufacture's Serial No.
STPEGS-2 No.
A THXE-40342/1FM2 1R122NSG201A B
THXE-40343/2FM2 1R122NSG201B C
THXE-40344/3FM2 1R122NSG201C D
THXE-40345/4FM2 1R122NSG201D The initial scope consisted of the following planned examinations:
- 1. Bobbin coil eddy current test (ET) of the full-length of all non-plugged tubing in each steam generator.
- 2. Motorized rotating probe head (or coil) (MRPC) ET of the following locations:
all final I-code indications, all freespan signals greater than 3 Volts on the bobbin coil 150 kI-z absolute channel that has not been verified to be less than five (5) percent through wall by the tube manufacture, all bobbin coil support-suppression mix channel eddy current ding or dent indications greater than 3 Volts and a sampling of others to cumulatively equal twenty (20) percent but not more than 200 tubes in each steam generator, all crevices at the top of the tubesheet with a measure depth in excess of 0.25 inches, all manufacturing burnish mark (MBM), ding and dent bobbin coil indications reported in Rows 1 and 2 U-Bends, all MBM, ding and dent bobbin coil indications exceeding 3.0 Volts, a total of 200 hot-leg top of tubesheet locations:
where the largest 20 bulge indications occur from one (1) inch above to four (4) inches below the secondary face, 2
where over-expansions were longer than 0.005 inches from one (1) inch above the secondary face to the tube-end, the remainder of locations distributed below the baffle plate cut-out region and on the periphery of the bundle from one (1) inch above to four (4) inches below the secondary face, a sample of top-of-tubesheet areas on the hot-leg (-200 tubesheet intersections per steam generator).
This scope exceeds the inspection requirements for tubes as defined in ASME Code Section XI IWB 2200 and 4.4.5.4 a.10 of the STPEGS technical specification (NUREG-1346). The PSI outage plan is consistent with the requirements of the second interval inservice inspection plan.
3
3.0 Personnel, Procedures, and Equipment 3.1 Personnel Qualifications The personnel who performed the ET data acquisition and analysis during the PSI were employed by Westinghouse Electric Company, LLC. and NDE Technology. They were certified in accordance with the requirements of IWA-2300 of ASME Code Section XI and the certification practices of their respective employers. All of the ET data analysts were certified as "qualified data analysts" (QDA's) for the steam generator work performed. A QDA is a data analyst, meeting the requirements to be certified at Level HA or III, who has passed rigorous testing of his ability to analyze a random selection of expertly-judged indications, from the Electric Power Research Institute's "PWR Steam Generator Examination Guidelines", Appendix G Performance Demonstration Database, for various steam generator designs and all types of known defects.
Before an ET data analyst could perform any analysis, they were required to successfully complete a STPEGS Site Specific Performance Demonstration (SSPD) steam generator ET data analysis-training program. The analyst-training program consisted of (1) ET data analysis course and (2) site specific practical training. The ET data analysis course consisted of a lecture conducted by the STPNOC ISI Engineer on topics of steam generator design, operating history, the data acquisition procedure, and analysis procedures to be used for the STPEGS-2 steam generator tube PSI examinations. The site specific practical training included hands-on review of data that contained signals, considered to have a potential to be detected during the PSI. The performance of the ANSER automated data screening software and settings were also demonstrated prior to use.
For personnel involved in the performance of the ET data acquisition and/or analysis, their name and certification levels are listed in Appendix A 3.2 Examination and Analysis Procedures All ET inspections were performed in accordance with the Westinghouse Nuclear Services Division (WNSD) procedure MRS 2.4.2 GEN-35, Rev. 10 entitled, "Eddy Current Inspection of Preservice and Inservice Heat Exchanger Tubing", with Field Change Request Number 1.
The bobbin coil examination technique was performed using inspection frequencies of 630, 300, 150 and 35 kHz in both the differential and absolute modes for each tube. A nominal pull speed of 40 inches per second with a digital signal-sampling rate of 1400 samples per second or greater was used. MRS 2.4.2 GEN-35 prescribes that the applicable Acquisition Technique Sheets (ACTS) will define the data sample rate and probe rotation and pull speeds. ACTS THX-01-101 listed these and other essential variables required for bobbin probe testing. Additionally, a slower test speed was used as needed to reduce probe "snap" noise in U-bend areas. This slower nominal pull speed of 24 inches per second used a digital signal sample rate of 850 samples per second or greater, and is listed on ACTS THX-03-101.
Three (3)-coil and single coil MIRPC designs were utilized for further diagnostic testing of signals of interest identified by bobbin. The three-coil design included one (1) plus-point and two (2) pancake coils. The three-coil probe examination technique was performed using the examination frequencies of 300, 200, 100, and 10 kHz. Also, the high frequency pancake coil on the three-coil probe head was operated at 600 kHz, in addition to 300 kHz. The single coil head design contained a plus-point coil. It was used to examine U-bend areas. The single coil examination technique that was performed using the 4
examination frequencies of 400, 300, 150 and 20 kHz. The three-coil and single coil test specifications are defined on ACTS TGX-02-101 and TGX-05-101, respectively.
The ET data analysts performed the analysis in accordance with WNSD procedure MRS-S SP-1215-THX, Rev. 0, titled, "Steam Generator Eddy Current Data Analysis Guidelines for the Pre-Service Inspection at South Texas Unit 2". All bobbin coil and RPC ET data for each steam generator tube or tube area examined were subjected to two (2) separate independent analyses in accordance with the analysis procedure.
The ET primary and secondary data analysis was performed independently and in separate isolated locations. Primary analysis of bobbin coil data was performed using ANSER automated data screening software (ADS). Manual analysis was done manually using ANSER software.
Results of all of the eddy current examinations were recorded on a digital, rewritable optical disk and the final resolution data sheets, which are stored as records. Each disk contains the raw ET data, primary, secondary, and resolution results for each calibration group. The optical disks also contain the system calibration and calibration verification with the dates and times for each calibration and verification. The unique number of the digital rewritable optical disk and the calibration group number have been recorded on the data sheets and optical disks. Therefore, the system calibration and calibration verification of the raw signals for each tube examined can be easily recalled.
3.3 Equipment All examinations were performed using Zetec EddyNet 98 software, Version 1.27, and the Zetec Miz-30 test instrument. The acquisition test instrument and software store and process the ET data in a digital format and have a significantly improved dynamic range and signal-to-noise ratio as compared to analog systems. The test system is capable of being operated at locations remote from the steam generators (e.g., in low radiation areas).
The bobbin coil examination program was performed using the replaceable probe head (RPH) design, WA-560-RPH and WA-540-RPH. The single and three-coil rotating heads were manufactured by Zetec, Inc. The three-coil probe consisted of one (1) plus-point coil (interwoven axially and circumferentially oriented coils that are differentially connected), one (1) 0.115 inch diameter pancake coil and one (1) shielded high frequency 0.080 inch diameter pancake coil. These inspections took place from either leg, depending on the location requiring inspection.
3.4 Calibration Standards The calibration standard design that was used for bobbin coil inspections was a combination in-line standard. It contained ASME Code Section XI flaws, simulated AVB wear flaws, a small 3 mil radial dent, and 1.12-inch-long tri-foil and circular shape stainless steel support rings. The calibration standard utilized for all of the MRPC inspections was a EP5-design guide tube design that contains several ID and OD, axially and circumferentially oriented, electro-discharge machined (EDM) notches in sufficient quantities to permit the sizing of indications if necessary.
K-_,
5
4.0 Summary of Examinations Bobbin coil ET techniques were performed on all non-plugged tubes in each of steam generators A, B, C, and D. All of these tubes were examined over their full length, from tube end to tube end or by multiple hot and cold leg exams. The following table summarizes the quantities of tubes that were examined using the bobbin coil ET techniques:
B C
D Tubes Examined 7584 7583J 752~L 7585i The following table summarizes the quantities of rotating head probe examinations and their areas of interest:
Steam Hot Leg Non-quantifiable Manufacture Dings at Dings in the Hot Leg Generator Over-expansions Bobbin Coil Burnish Marks Supports Freespan Expansions Signals (NQS's)
(MBM's)
(Dents)
A 18 1
4 127 62 201 B
18 1
3 56 32 195 C
7 6
7 118 65 200 D
9 2
7 9
41 203 Totals 52 10 21 310 200 799 The tube areas that were examined using a rotating head probe are listed in Appendix B, "Tubes Examined by MRPC".
6
5.0 Examination Results and Corrective Actions The location of the indications were recorded relative to the adjacent tube support, baffle plate and/or anti vibration bar. The tube support plates and baffle plates were numbered consecutively from 0111 to the top support plate. The anti-vibration bars were numbered AVI through AV16 from the hot leg to the cold leg side, respectively. Indications in the tubesheet area were recorded relative to TEH or TSH (hot leg) or TEC or TSC (cold leg) depending on whether the indications were at the tube end (E) or secondary face (S). In addition, the vertical distances from these landmarks to flaws were recorded, with positive being upward from the reporting structure. This convention was used through out the tube bundle, except at support structures, where a plus/minus 2-inch window was used when reporting indications that were at or near support structures.
All ET indications reported during the PSI were assigned three-letter codes. The three-letter code reflects the suspected nature of the discontinuity and the need to perform an additional inspection and/or repair action. Some of the codes used during the PSI are as follows:
DNG - ding, located in freespan only DNT - dent, located at tube support and baffle plates only NQI - non-quantifiable indication MBM - manufacture burnish mark PVN -permeability variation BLG -bulge PLP - possible loose part NQI - non-quantifiable indication NQS -non-quantifiable signal OXP - over expansion in tubesheet CRD - crevice depth from top of tubesheet AVG - average tubesheet inner diameter The ET data was analyzed using the setup, data screening and reporting requirements defined in the analysis technique sheets (ANTS) that follow:
THX-A-101 -Bobbin THX-B-101 - 3 Coil Plus Point THX-C-101 - Single Coil Plus Point The location of all bobbin coil signals, that were initially reported with a three-letter code ending with the letter "I" (I-codes like NQI), were tested by MPRC ET and confirmed to be non-flaw-like. Therefore, the I-Code was changed to a final S-Code (e.g.; NQS). All DNG, DNT and MBM indications greater than 3.00 Volts were also MRPC tested and confirmed to be non-flaw-like.
There were no axial or circumferential crack-like indication reported in any of the four steam generators. No wear of any kind was reported in any of the four steam generators.
7
The following table summarizes the final results for the PSI:
B C
D MBM Tubes/Indications 38 / 40 65 / 83 29 / 32 49 / 55 DNG Tubes/Indications 219/264 158/184 120/149 116/132 DNT Tubes/Indications 271/431 150/188 280/428 30/33 NQS Tubes/Indications 1 / 1 1 / 1 6/6 2 / 2 BLG Tubes/Indications 13/14 8/12 8/8 12/17 PVN Tubes/Indications 2/2 0/0 0/0 0 / 0 All dents and dings that were reported in each steam generator are listed in Appendix C, "Dings and Dents". All anomalous signals (e.g.; ADS, BLG, MBM) that were reported in each steam generator are reported in Appendix D, "Tubes with Other Anomalous Signals".
In addition to the dual bobbin coil data degradation analysis, a single profile analysis was performed on both cold and hot leg tubesheets. There were five (5) conditions the ANSER profile software was screening the data to determine. They were crevice depths, average inner diameters, skip rolls, over expansions, and expansion bulges. The following are the results from the profile analysis:
Several over-expansions (OXPs) were detected and subjected to MRPC testing. The MIRPC detected no abnormal conditions.
There were no crevice depths (CRDs) exceeding the 0.25-inch threshold for issuance of a deviation report.
No average inner diameters (AVGs) were reported below 0.610 inches. That indicates there are no unexpanded tubes in the tubesheets.
No expansion skip rolls were reported.
No expansion buldges in the tubesheet were reported by the profile analysis.
The total numbers of degraded and defective tubes detected during the bobbin coil ET and MRPC ET are as follows:
5.1 Steam Generator A There were no tubes considered degraded and defective. There were no tubes removed from service..
5.2 Steam Generator B There were no tubes considered degraded and defective. There were no tubes removed from service.
5.3 Steam Generator C There were no tubes considered degraded and defective. There were no tubes removed from service.
5.4 Steam Generator D There were no tubes considered degraded and defective. There were no tubes removed from service.
Six (6) tubes were plugged during the manufacture of the STPEGS-2 replacement steam generators and prior to the PSI. No tubes were removed from service as a result of conditions detected by the PSI. The tubes removed from service are depicted in Appendix E, "Tubes Removed from Service Prior to Installation".
6.0 Certification of Inspections An ASME Code Section XI NIS-1 form "Owner's Report for Inservice Inspections", has been prepared to certify the STPEGS Unit 2 PSI examinations described in this Summary Report. The STPEGS-2 PSI examinations have been certified by our ANII, Factory Mutual Insurance Company, on the NIS-1 form included in Appendix F.
APPENDIX A LISTING OF CERTIFIED PERSONNEL
Appendix A Listing of Certified Personnel NAME Analysis Crew Anderson, D Beiers, T Ethridge, G Gootz, T Nelson, D Pocratsky, R Richmond, M Sheldon, J Siegel, R Stokke, T Thompson, V EC LEVEL COMPANY IIA IliA IliA III IliA III lilA lilA lilA lilA lilA NDE NDE NDE w
NDE w
NDE NDE NDE NDE NDE REP - FUNCTION Secondary Secondary I QDA Primary ADS Secondary Senior/Resos Resolutions Primary ADS Secondary Secondary Secondary A-1
Appendix A Listing of Certified Personnel NAME EC LEVEL COMPANY REP - FUNCTION Acquisition Crew Chapla, J II W
Acquisition Estel, J II W
Acquisition Moats, C II W
Acquisition Patton, B I
W Acquisition Reif, D II W
Acquisition Schachte, D II W
Acquisition Smith, A II W
Acquisition W - WNSD NDE - NDE Technologies A-2
APPENDIX B TUBES EXAMINED BY MRPC
Tubes Examined By RPC SG-A ROW COL BEGIN TEST END TEST PROBE 2
34 TEH TSH 0.560 ZPSHF 2
34 TEH TSH 0.560 ZPSHF 2
54 TSH TSH 0.560 ZPSHF 2
58 TSH TSH 0.560 ZPSHF 2
62 TSH TSH 0.560 ZPSHF 2
66 TSH TSH 0.560 ZPSHF 2
86 TSH TSH 0.560 ZPSHF 2
90 TSH TSH 0.560 ZPSHF 2
94 TSH TSH 0.560 ZPSHF 2
98 09C 09H 0.520 ZPUGR 2
98 TSH TSH 0.560 ZPSHF 2
102 TSH TSH 0.560 ZPSHF 3
53 TSH TSH 0.560 ZPSHF 3
63 TSH TSH 0.560 ZPSHF 3
93 TSH TSH 0.560 ZPSHF 3
103 TSH TSH 0.560 ZPSHF 4
4 TSH TSH 0.560 ZPSHF 4
60 TSH TSH 0.560 ZPSHF 4
142 0iC 02C 0.560 ZPSHF 4
154 TSH TSH 0.560 ZPSHF 6
54 TSH TSH 0.560 ZPSHF 6
58 TSH TSH 0.560 ZPSHF 6
62 TSH TSH 0.560 ZPSHF 6
66 TSH TSH 0.560 ZPSHF 6
86 TSH TSH 0.560 ZPSHF 6
90 TSH TSH 0.560 ZPSHF 6
94 TSH TSH 0.560 ZPSHF 6
98 TSH TSH 0.560 ZPSHF 6
100 TSH TSH 0.560 ZPSHF 6
102 TSH TSH 0.560 ZPSHF 6
152 TSH TSH 0.560 ZPSHF 8
58 TSH TSH 0.560 ZPSHF 8
88 TSH TSH 0.560 ZPSHF 8
98 TSH TSH 0.560 ZPSHF 10 4
TSH TSH 0.560 ZPSHF 10 54 TSH TSH 0.560 ZPSHF 10 58 TSH TSH 0.560 ZPSHF 10 62 TSH TSH 0.560 ZPSHF 10 66 TSH TSH 0.560 ZPSHF 10 86 TSH TSH 0.560 ZPSHF 10 90 TSH TSH 0.560 ZPSHF 10 94 TSH TSH 0.560 ZPSHF 10 98 TSH TSH 0.560 ZPSHF 10 102 TSH TSH 0.560 ZPSHF 10 154 TSH TSH 0.560 ZPSHF 11 61 07C 08C 0.560 ZPSHF 11 61 07C 08C 0.560 ZPSHF 12 32 TSC TSC 0.560 ZPSHF 12 100 07C 08C 0.560 ZPSHF 12 138 TEH TSH 0.560 ZPSHF 13 63 TSH TSH 0560 ZPSHF B-1 Appendix B
Tubes Examined By RPC SG -A 13 87 TEH TSH 0.560 ZPSHF 13 93 TSH TSH 0.560 ZPSHF 13 151 TSH TSH 0.560 ZPSHF 13 153 TEH TSH 0.560 ZPSHF 14 58 TSH TSH 0.560 ZPSHF 14 62 TSH TSH 0.560 ZPSHF 14 66 TSH TSH 0.560 ZPSHF 14 86 TSH TSH 0.560 ZPSHF 14 88 TSH TSH 0.560 ZPSHF 14 90 TSH TSH 0.560 ZPSHF 14 94 TSH TSH 0.560 ZPSHF 14 98 TSH TSH 0.560 ZPSHF 15 89 TEH TSH 0.560 ZPSHF 16 4
TSH TSH 0.560 ZPSHF 16 64 02C 03C 0.560 ZPSHF 16 154 TSH TSH 0.560 ZPSHF 17 49 06C 07C 0.560 ZPSHF 17 49 07C 08C 0.560 ZPSHF 17 49 07C 08C 0.560 ZPSHF 18 58 TSH TSH 0.560 ZPSHF 18 62 TSH TSH 0.560 ZPSHF 18 66 TSH TSH 0.560 ZPSHF 18 86 TSH TSH 0.560 ZPSHF 18 88 TSH TSH 0.560 ZPSHF 18 90 TSH TSH 0.560 ZPSHF 18 94 TSH TSH 0.560 ZPSHF 18 98 TSH TSH 0.560 ZPSHF 19 53 03C 04C 0.560 ZPSHF 21 71 05C 06C 0.560 ZPSHF 21 149 TSH TSH 0.560 ZPSHF 22 4
TSH TSH 0.560 ZPSHF 22 58 TSH TSH 0.560 ZPSHF 22 62 TSH TSH 0.560 ZPSHF 22 66 TSH TSH 0.560 ZPSHF 22 70 TSH TSH 0.560 ZPSHF 22 74 TSH TSH 0.560 ZPSHF 22 78 TSH TSH 0.560 ZPSHF 22 78 TSH TSH 0.560 ZPSHF 22 82 TSH TSH 0.560 ZPSHF 22 86 TSH TSH 0.560 ZPSHF 22 90 TSH TSH 0.560 ZPSHF 22 94 TSH TSH 0.560 ZPSHF 22 98 TSH TSH 0.560 ZPSHF 22 148 TSH TSH 0.560 ZPSHF 23 59 TSC 01C 0.560 ZPSHF 23 63 TSH TSH 0.560 ZPSHF 23 73 TSH TSH 0.560 ZPSHF 23 73 TSH TSH 0.560 ZPSHF 23 77 TSH TSH 0.560 ZPSHF 23 83 TSH TSH 0.560 ZPSHF 23 93 TSH TSH 0.560 ZPSHF 25 21 02H 03H 0.560 ZPSHF B-2 Appendix B
Tubes Examined By RPC SG - A 26 62 TSH TSH 0.560 ZPSHF 26 66 TSH TSH 0.560 ZPSHF 26 70 TSH TSH 0.560 ZPSHF 26 74 TSH TSH 0.560 ZPSHF 26 78 TSH TSH 0.560 ZPSHF 26 78 TSH TSH 0.560 ZPSHF 26 82 TSH TSH 0.560 ZPSHF 26 86 TSH TSH 0.560 ZPSHF 26 88 01C 02C 0.560 ZPSHF 26 90 TSH TSH 0.560 ZPSHF 26 94 TSH TSH 0.560 ZPSHF 26 148 TSH TSH 0.560 ZPSHF 27 39 TSC TSC 0.560 ZPSHF 27 57 08C 09C 0.560 ZPSHF 27 61 08C 09C 0.560 ZPSHF 27 93 09C 09C 0.560 ZPSHF 28 4
TSH TSH 0.560 ZPSHF 28 68 TSH TSH 0.560 ZPSHF 28 78 TSH TSH 0.560 ZPSHF 28 88 TSH TSH 0.560 ZPSHF 28 148 TSH TSH 0.560 ZPSHF 29 5
TSH TSH 0.560 ZPSHF 29 149 TSH TSH 0.560 ZPSHF 30 66 TSH TSH 0.560 ZPSHF 30 70 TSH TSH 0.560 ZPSHF 30 74 TSH TSH 0.560 ZPSHF 30 78 TSH TSH 0.560 ZPSHF 30 82 TSH TSH 0.560 ZPSHF 30 86 TSH TSH 0.560 ZPSHF 30 90 TSH TSH 0.560 ZPSHF 30 124 TEH TSH 0.560 ZPSHF 32 78 TEH TSH 0.560 ZPSHF 33 73 TSH TSH 0.560 ZPSHF 33 83 TSH TSH 0.560 ZPSHF 34 70 TSH TSH 0.560 ZPSHF 34 74 TSH TSH 0.560 ZPSHF 34 78 TSH TSH 0.560 ZPSHF 34 82 TSH TSH 0.560 ZPSHF 34 84 TSH TSH 0.560 ZPSHF 34 86 TSH TSH 0.560 ZPSHF 34 134 05C 06C 0.560 ZPSHF 34 148 TSH TSH 0.560 ZPSHF 35 35 TEH TSH 0.560 ZPSHF 35 35 TEH TSH 0.560 ZPSHF 35 93 FBC 01C 0.560 ZPSHF 37 5
TSH TSH 0.560 ZPSHF 37 103 03C 04C 0.560 ZPSHF 37 149 TSH TSH 0.560 ZPSHF 38 74 TSH TSH 0.560 ZPSHF 38 78 TSH TSH 0.560 ZPSHF 38 82 TSH TSH 0.560 ZPSHF 39 39 06C 07C 0.560 ZPSHF B-3 Appendix B
Tubes Examined By RPC SG -A 39 149 TSH TSH 0.560 ZPSHF 40 10 TSH TSH 0.560 ZPSHF 40 86 01C 02C 0.560 ZPSHF 40 86 TSC FBC 0.560 ZPSHF 40 92 08C 09C 0.560 ZPSHF 40 138 08H 09H 0.560 ZPSHF 40 148 TSH TSH 0.560 ZPSHF 45 27 05C 06C 0.560 ZPSHF 45 27 FBC 01C 0.560 ZPSHF 45 149 TSH TSH 0.560 ZPSHF 46 10 TSH TSH 0.560 ZPSHF 46 22 08C 09C 0.560 ZPSHF 46 148 TSH TSH 0.560 ZPSHF 48 46 TEH TSH 0.560 ZPSHF 52 10 TSH TSH 0.560 ZPSHF 52 36 TEH TSH 0.560 ZPSHF 52 142 TSH TSH 0.560 ZPSHF 53 13 TSH TSH 0.560 ZPSHF 53 141 TSH TSH 0.560 ZPSHF 54 12 TSH TSH 0.560 ZPSHF 54 84 o1C 02C 0.560 ZPSHF 54 90 07C 08C 0.560 ZPSHF 55 69 FBC FBC 0.560 ZPSHF 58 36 TEH TSH 0.560 ZPSHF 58 66 08C 09C 0.560 ZPSHF 58 136 TSH TSH 0.560 ZPSHF 58 142 TSH TSH 0.560 ZPSHF 59 17 FBC 01C 0.560 ZPSHF 59 17 FBC 01C 0.560 ZPSHF 59 69 08H 09H 0.560 ZPSHF 59 117 08C 09C 0.560 ZPSHF 60 30 08C 09C 0.560 ZPSHF 60 30 08C 09C 0.560 ZPSHF 60 30 08C 09C 0.560 ZPSHF 60 30 08H 09H 0.560 ZPSHF 60 30 08H 09H 0.560 ZPSHF 60 30 FBC 01C 0.560 ZPSHF 60 48 TSC FBC 0.560 ZPSHF 61 13 TSH TSH 0.560 ZPSHF 61 141 TSH TSH 0.560 ZPSHF 63 35 TEH TSH 0.560 ZPSHF 63 79 02C 03C 0.560 ZPSHF 64 16 TSH TSH 0.560 ZPSHF 64 136 TSH TSH 0.560 ZPSHF 64 142 TSH TSH 0.560 ZPSHF 65 13 08H 09H 0.560 ZPSHF 65 13 08H 09H 0.560 ZPSHF 65 13 TSH TSH 0.560 ZPSHF 65 71 03C 04C 0.560 ZPSHF 67 37 08H 09H 0.560 ZPSHF 68 84 07C 08C 0.560 ZPSHF 69 17 TSH TSH 0.560 ZPSHF B-4 Appendix B
Tubes Examined By RPC SG-A 69 141 TSH TSH 0.560 ZPSHF 70 16 TSH TSH 0.560 ZPSHF 70 130 07C 08C 0.560 ZPSHF 70 136 TSH TSH 0.560 ZPSHF 71 87 TSC FBC 0.560 ZPSHF 72 86 01C 02C 0.560 ZPSHF 72 126 04C 05C 0.560 ZPSHF 72 126 04C 05C 0.560 ZPSHF 73 125 09C 09C 0.560 ZPSHF 74 48 09H 09H 0.560 ZPSHF 74 120 03C 04C 0.560 ZPSHF 74 132 TSH TSH 0.560 ZPSHF 76 22 TSH TSH 0.560 ZPSHF 76 130 TSH TSH 0.560 ZPSHF 76 136 TSH TSH 0.560 ZPSHF 77 21 TSH TSH 0.560 ZPSHF 77 109 TSC TSC 0.560 ZPSHF 77 133 07C 08C 0.560 ZPSHF 77 133 TSH TSH 0.560 ZPSHF 78 38 08C 09C 0.560 ZPSHF 78 38 08C 09C 0.560 ZPSHF 78 38 08C 09C 0.560 ZPSHF 79 31 02C 03C 0.560 ZPSHF 79 125 FBC 01C 0.560 ZPSHF 79 125 TEH TSH 0.560 ZPSHF 80 132 TSH TSH 0.560 ZPSHF 81 87 TSC FBC 0.560 ZPSHF 82 22 TSH TSH 0.560 ZPSHF 82 126 03C 04C 0.560 ZPSHF 82 130 TSH TSH 0.560 ZPSHF 82 136 TSH TSH 0.560 ZPSHF 83 129 TSH TSH 0.560 ZPSHF 85 31 02C 03C 0.560 ZPSHF 85 105 08C 09C 0.560 ZPSHF 85 133 TSH TSH 0.560 ZPSHF 86 60 03C 04C 0.560 ZPSHF 86 100 03C 03C 0.560 ZPSHF 86 130 TSH TSH 0.560 ZPSHF 88 28 TSH TSH 0.560 ZPSHF 88 124 TSH TSH 0.560 ZPSHF 88 130 TSH TSH 0.560 ZPSHF 89 85 03C 04C 0.560 ZPSHF 89 89 08C 09C 0.560 ZPSHF 90 68 TEH TSH 0.560 ZPSHF 91 89 05C 06C 0.560 ZPSHF 92 40 TSC FBC 0.560 ZPSHF 93 29 TSH TSH 0.560 ZPSHF 93 117 TSH TSH 0.560 ZPSHF 93 125 TSH TSH 0.560 ZPSHF 94 28 TSH TSH 0.560 ZPSHF 94 118 TSH TSH 0.560 ZPSHF 94 124 TSH TSH 0.560 ZPSHF B-5 Appendix B
Tubes Examined By RPC SG-A 95 89 06C 07C 0.560 ZPSHF 95 89 FBC 01C 0.560 ZPSHF 95 89 TSC FBC 0.560 ZPSHF 95 117 TSH TSH 0.560 ZPSHF 97 99 03H 04H 0.560 ZPSHF 99 31 09C 09C 0.560 ZPSHF 99 31 09C 09C 0.560 ZPSHF 100 34 TSH TSH 0.560 ZPSHF 100 118 TSH TSH 0.560 ZPSHF 100 124 TSH TSH 0.560 ZPSHF 101 37 TSH TSH 0.560 ZPSHF 101 117 TSH TSH 0.560 ZPSHF 101 123 09C 09C 0.560 ZPSHF 101 123 09C 09C 0.560 ZPSHF 102 108 04C 04C 0.560 ZPSHF 102 108 04C 05C 0.560 ZPSHF 102 108 04C 05C 0.560 ZPSHF 103 55 TSC FBC 0.560 ZPSHF 104 38 09C 09C 0.560 ZPSHF 104 86 05C 06C 0.560 ZPSHF 105 117 09C 09C 0.560 ZPSHF 105 117 09C 09C 0.560 ZPSHF 106 36 03C 04C 0.560 ZPSHF 106 40 TSH TSH 0.560 ZPSHF 106 56 07C 08C 0.560 ZPSHF 106 82 08C 09C 0.560 ZPSHF 106 106 TSH TSH 0.560 ZPSHF 106 112 TSH TSH 0.560 ZPSHF 106 118 TSH TSH 0.560 ZPSHF 107 113 09C 09C 0.560 ZPSHF 107 113 09C 09C 0.560 ZPSHF 107 119 TSH TSH 0.560 ZPSHF 108 84 04C 04C 0.560 ZPSHF 108 116 09C 09C 0.560 ZPSHF 108 116 09C 09C 0.560 ZPSHF 109 45 TSH TSH 0.560 ZPSHF 109 109 TSH TSH 0.560 ZPSHF 109 117 TSH TSH 0.560 ZPSHF 110 114 09C 09C 0.560 ZPSHF 110 114 09C 09C 0.560 ZPSHF 112 46 TSH TSH 0.560 ZPSHF 112 100 TEH TSH 0.560 ZPSHF 112 102 TSC FBC 0.560 ZPSHF 112 106 TSH TSH 0.560 ZPSHF 112 112 TSH TSH 0.560 ZPSHF 112 114 09C 09C 0.560 ZPSHF 112 114 09C 09C 0.560 ZPSHF 113 97 TEH TSH 0.560 ZPSHF 113 113 A7 09C 0.520 ZPUGR 115 85 TEH TSH 0.560 ZPSHF 116 48 TSH TSH 0.560 ZPSHF 116 94 TEH TSH 0.560 ZPSHF B-6 Appendix B
Tubes Examined By RPC SG-A 116 98 TSH TSH 0.560 ZPSHF 116 106 09C 09C 0.560 ZPSHF 116 106 09C 09C 0.560 ZPSHF 117 53 TSH TSH 0.560 ZPSHF 117 101 09C 09C 0.560 ZPSHF 117 101 09C 09C 0.560 ZPSHF 117 101 TSH TSH 0.560 ZPSHF 117 107 09C 09C 0.560 ZPSHF 117 107 09C 09C 0.560 ZPSHF 118 52 TSH TSH 0.560 ZPSHF 118 58 TSH TSH 0.560 ZPSHF 118 100 TSH TSH 0.560 ZPSHF 118 106 TSH TSH 0.560 ZPSHF 119 67 03C 04C 0.560 ZPSHF 119 103 09C 09C 0.560 ZPSHF 119 103 09C 09C 0.560 ZPSHF 119 105 01C 02C 0.560 ZPSHF 119 105 09C 09C 0.560 ZPSHF 119 105 09C 09C 0.560 ZPSHF 120 100 09C 09C 0.560 ZPSHF 120 102 09C 09C 0.560 ZPSHF 120 102 09C 09C 0.560 ZPSHF 120 104 TSH TSH 0.560 ZPSHF 121 93 09C 09C 0.560 ZPSHF 121 93 09C 09C 0.560 ZPSHF 121 95 09C 09C 0.560 ZPSHF 121 95 09C 09C 0.560 ZPSHF 121 99 09C 09C 0.560 ZPSHF 121 99 09C 09C 0.560 ZPSHF 121 101 09C 09C 0.560 ZPSHF 121 101 09C 09C 0.560 ZPSHF 122 60 TSH TSH 0.560 ZPSHF 122 64 01C 02C 0.560 ZPSHF 122 64 06C 07C 0.560 ZPSHF 122 64 07C 08C 0.560 ZPSHF 122 70 07C 09C 0.560 ZPSHF 122 70 07C 09C 0.560 ZPSHF 122 70 07C 09C 0.560 ZPSHF 122 70 09C 09C 0.560 ZPSHF 122 70 09C 09C 0.560 ZPSHF 122 98 09C 09C 0.560 ZPSHF 122 98 09C 09C 0.560 ZPSHF 123 61 09C 09C 0.560 ZPSHF 123 61 09C 09C 0.560 ZPSHF 123 63 09C 09C 0.560 ZPSHF 123 63 09C 09C 0.560 ZPSHF 123 87 09C 09C 0.560 ZPSHF 123 87 09C 09C 0.560 ZPSHF 123 91 09C 09C 0.560 ZPSHF 123 91 09C 09C 0.560 ZPSHF 123
.93 09C 09C 0.560 ZPSHF 123 93 09C 09C 0.560 ZPSHF B-7 Appendix B
Tubes Examined By RPC SG-A 123 97 09C 09C 0.560 ZPSHF 123 97 09C 09C 0.560 ZPSHF 124 64 09C 09C 0.560 ZPSHF 124 64 09C 09C 0.560 ZPSHF 124 64 TSH TSH 0.560 ZPSHF 124 66 09C 09C 0.560 ZPSHF 124 66 09C 09C 0.560 ZPSHF 124 70 TSH TSH 0.560 ZPSHF 124 76 TSH TSH 0.560 ZPSHF 124 82 TSH TSH 0.560 ZPSHF 124 88 09C 09C 0.560 ZPSHF 124 88 09C 09C 0.560 ZPSHF 124 88 TSH TSH 0.560 ZPSHF 124 90 08H 09H 0.560 ZPSHF 124 90 08H 09H 0.560 ZPSHF 124 90 09C 09C 0.560 ZPSHF 124 90 09C 09C 0.560 ZPSHF 124 92 09C 09C 0.560 ZPSHF 124 92 09C 09C 0.560 ZPSHF 124 94 09C 09C 0.560 ZPSHF 124 94 09C 09C 0.560 ZPSHF 124 94 TSH TSH 0.560 ZPSHF 124 96 09C 09C 0.560 ZPSHF 124 96 09C 09C 0.560 ZPSHF 124 96 09C 09C 0.560 ZPSHF 125 63 09C 09C 0.560 ZPSHF 125 63 09C 09C 0.560 ZPSHF 125 65 09C 09C 0.560 ZPSHF 125 65 09C 09C 0.560 ZPSHF 125 67 09C 09C 0.560 ZPSHF 125 67 09C 09C 0.560 ZPSHF 125 69 09C 09C 0.560 ZPSHF 125 69 09C 09C 0.560 ZPSHF 125 69 TSH TSH 0.560 ZPSHF 125 77 TSH TSH 0.560 ZPSHF 125 85 09C 09C 0.560 ZPSHF 125 85 09C 09C 0.560 ZPSHF 125 85 TSH TSH 0.560 ZPSHF 125 87 09C 09C 0.560 ZPSHF 125 87 09C 09C 0.560 ZPSHF 125 89 09C 09C 0.560 ZPSHF 125 89 09C 09C 0.560 ZPSHF 125 91 09C 09C 0.560 ZPSHF 125 91 09C 09C 0.560 ZPSHF 125 93 TSH TSH 0.560 ZPSHF 126 68 09C 09C 0.560 ZPSHF 126 68 09C 09C 0.560 ZPSHF 126 70 09C 09C 0.560 ZPSHF 126 70 09C 09C 0.560 ZPSHF 126 74 09C 09C 0.560 ZPSHF 126 74 09C 09C 0.560 ZPSHF 126 82 09C 09C 0.560 ZPSHF B-8 Appendix B
Tubes Examined By RPC SG-A 126 82 09C 09C 0.560 ZPSHF 126 86 09C 09C 0.560 ZPSHF 126 86 09C 09C 0.560 ZPSHF 126 88 09C 09C 0.560 ZPSHF 126 88 09C 09C 0.560 ZPSHF 127 69 09C 09C 0.560 ZPSHF 127 69 09C 09C 0.560 ZPSHF 127 71 09C 09C 0.560 ZPSHF 127 71 09C 09C 0.560 ZPSHF 127 73 09C 09C 0.560 ZPSHF 127 73 09C 09C 0.560 ZPSHF 127 75 09C 09C 0.560 ZPSHF 127 75 09C 09C 0.560 ZPSHF 127 77 09C 09C 0.560 ZPSHF 127 77 09C 09C 0.560 ZPSHF 127 79 09C 09C 0.560 ZPSHF 127 79 09C 09C 0.560 ZPSHF 127 81 09C 09C 0.560 ZPSHF 127 81 09C 09C 0.560 ZPSHF 127 83 09C 09C 0.560 ZPSHF 127 83 09C 09C 0.560 ZPSHF 127 85 09C 09C 0.560 ZPSHF 127 85 09C 09C 0.560 ZPSHF B-9 Appendix B
Tubes Examined By RPC SG-B ROW COL BEGIN TEST END TEST PROBE 1
53 TSH TSH
.560 ZPSHF 1
57 TSH TSH
.560 ZPSHF 1
61 TSH TSH
.560 ZPSHF 1
65 TSH TSH
.560 ZPSHF 1
69 TSH TSH
.560 ZPSHF 1
73 TSH TSH
.560 ZPSHF 1
85 TSH TSH
.560 ZPSHF 1
89 TSH TSH
.560 ZPSHF 1
93 TSH TSH
.560 ZPSHF 1
97 TSH TSH
.560 ZPSHF 1
101 TSH TSH
.560 ZPSHF 3
59 TSH TSH
.560 ZPSHF 3
61 TSH TSH
.560 ZPSHF 3
67 TSH TSH
.560 ZPSHF 3
73 TSH TSH
.560 ZPSHF 3
91 TSH TSH
.560 ZPSHF 3
99 TSH TSH
.560 ZPSHF 3
155 TSH TSH
.560 ZPSHF 4
4 TSH TSH
.560 ZPSHF 4
116 01C 02C
.560 ZPSHF 4
154 TSH TSH
.560 ZPSHF 5
17 02C 03C
.560 ZPSHF 5
53 TSH TSH
.560 ZPSHF 5
57 TSH TSH
.560 ZPSHF 5
61 TSH TSH
.560 ZPSHF 5
65 TSH TSH
.560 ZPSHF 5
69 TSH TSH
.560 ZPSHF 5
73 TSH TSH
.560 ZPSHF 5
89 TSH TSH
.560 ZPSHF 5
93 TSH TSH
.560 ZPSHF 5
97 TSH TSH
.560 ZPSHF 5
101 TSH TSH
.560 ZPSHF 7
3 TEH TSH
.560 ZPSHF 7
61 TSH TSH
.560 ZPSHF 9
57 TSH TSH
.560 ZPSHF 9
59 TSH TSH
.560 ZPSHF 9
61 TSH TSH
.560 ZPSHF 9
65 TSH TSH
.560 ZPSHF 9
69 TSH TSH
.560 ZPSHF 9
89 TSH TSH
.560 ZPSHF 9
93 TSH TSH
.560 ZPSHF 9
97 TSH TSH
.560 ZPSHF 9
101 TSH TSH
.560 ZPSHF 10 4
TSH TSH
.560 ZPSHF 10 154 TSH TSH
.560 ZPSHF 11 59 TSH TSH
.560 ZPSHF 11 67 TSH TSH
.560 ZPSHF 11 91 TSH TSH
.560 ZPSHF 11 99 TSH TSH
.560 ZPSHF 11 131 TEH TSH
.560 ZPSHF 11 139 TEH TSH
.560 ZPSHF B-I Appendix B
Tubes Examined By RPC SG-B 13 17 TEH TSH
.560 ZPSHF 13 57 TSH TSH
.560 ZPSHF 13 59 TSH TSH
.560 ZPSHF 13 61 TSH TSH
.560 ZPSHF 13 65 TSH TSH
.560 ZPSHF 13 69 TSH TSH
.560 ZPSHF 13 89 TSH TSH
.560 ZPSHF 13 93 TSH TSH
.560 ZPSHF 13 97 TSH TSH
.560 ZPSHF 13 101 TSH TSH
.560 ZPSHF 14 96 TEH TSH
.560 ZPSHF 16 4
TSH TSH
.560 ZPSHF 16 154 TSH TSH
.560 ZPSHF 17 57 TSH TSH
.560 ZPSHF 17 59 TSH TSH
.560 ZPSHF 17 61 TSH TSH
.560 ZPSHF 17 65 TSH TSH
.560 ZPSHF 17 69 TSH TSH
.560 ZPSHF 17 89 TSH TSH
.560 ZPSHF 17 93 TSH TSH
.560 ZPSHF 17 97 TSH TSH
.560 ZPSHF 19 59 TSH TSH
.560 ZPSHF 19 67 TSH TSH
.560 ZPSHF 19 85 TSH TEH
.560 ZPSHF 19 91 TSH TSH
.560 ZPSHF 19 99 TSH TSH
.560 ZPSHF 20 30 03C 04C
.560 ZPSHF 21 61 TSH TSH
.560 ZPSHF 21 65 TSH TSH
.560 ZPSHF 21 69 TSH TSH
.560 ZPSHF 21 89 TSH TSH
.560 ZPSHF 21 93 TSH TSH
.560 ZPSHF 21 97 TSH TSH
.560 ZPSHF 21 149 TSH TSH
.560 ZPSHF 22 4
TSH TSH
.560 ZPSHF 22 46 TEH TSH
.560 ZPSHF 22 148 TSH TSH
.560 ZPSHF 22 150 TSH TSH
.560 ZPSHF 25 61 TSH TSH
.560 ZPSHF 25 65 TSH TSH
.560 ZPSHF 25 69 TSH TSH
.560 ZPSHF 25 73 TSH TSH
.560 ZPSHF 25 77 TSH TSH
.560 ZPSHF 25 81 TSH TSH
.560 ZPSHF 25 85 TSH TSH
.560 ZPSHF 25 89 TSH TSH
.560 ZPSHF 25 93 TSH TSH
.560 ZPSHF 26 68 08C 09C
.560 ZPSHF 26 68 08C 09C
.560 ZPSHF 27 31 TSC FBC
.560 ZPSHF 27 67 TSH TSH
.560 ZPSHF 27 75 TSH TSH
.560 ZPSHF B-2 Appendix B
Tubes Examined By RPC SG-B 27 83 TSH TSH
.560 ZPSHF 27 91 TSH TSH
.560 ZPSHF 27 133 TEH TSH
.560 ZPSHF 28 4
TSC FBC
.560 ZPSHF 28 4
TSH TSH
.560 ZPSHF 28 148 TSH TSH
.560 ZPSHF 28 150 TSH TSH
.560 ZPSHF 29 5
TSH TSH
.560 ZPSHF 29 15 TEH TSH
.560 ZPSHF 29 65 TSH TSH
.560 ZPSHF 29 69 TSH TSH
.560 ZPSHF 29 73 TSH TSH
.560 ZPSHF 29 77 TSH TSH
.560 ZPSHF 29 81 TSH TSH
.560 ZPSHF 29 83 TSH TSH
.560 ZPSHF 29 85 TSH TSH
.560 ZPSHF 29 89 TSH TSH
.560 ZPSHF 29 93 TSH TSH
.560 ZPSHF 29 149 TSH TSH
.560 ZPSHF 30 20 04C 05C
.560 ZPSHF 30 104 01C 02C
.560 ZPSHF 31 83 TSH TSH
.560 ZPSHF 33 69 TSH TSH
.560 ZPSHF 33 73 TSH TSH
.560 ZPSHF 33 77 TSH TSH
.560 ZPSHF 33 81 TSH TSH
.560 ZPSHF 33 85 TSH TSH
.560 ZPSHF 33 89 TSH TSH
.560 ZPSHF 33 119 0iC 02C
.560 ZPSHF 34 148 TSH TSH
.560 ZPSHF 35 75 TSH TSH
.560 ZPSHF 35 81 08H 09H
.560 ZPSHF 35 81 TSH TSH
.560 ZPSHF 35 83 TSH TSH
.560 ZPSHF 35 145 08H 09H
.560 ZPSHF 35 145 08H 09H
.560 ZPSHF 37 5
TSH TSH
.560 ZPSHF 37 49 08H 09H
.560 ZPSHF 37 73 TSH TSH
.560 ZPSHF 37 77 TSH TSH
.560 ZPSHF 37 81 TSH TSH
.560 ZPSHF 37 85 TSH TSH
.560 ZPSHF 37 149 TSH TSH
.560 ZPSHF 39 141 TEH TSH
.560 ZPSHF 40 10 TSH TSH
.560 ZPSHF 40 148 TSH TSH
.560 ZPSHF 45 149 TSH TSH
.560 ZPSHF 46 10 TSH TSH
.560 ZPSHF 46 146 TSH TSH
.560 ZPSHF 46 148 TSH TSH
.560 ZPSHF 47 25 01H 02H
.560 ZPSHF 47 25 05H 05H
.560 ZPSHF B-3 Appendix B
Tubes Examined By RPC SG-B 47 25 06H 07H
.560 ZPSHF 51 137 TSH TSH
.560 ZPSHF 52 10 TSH TSH
.560 ZPSHF 52 126 08H 09H
.560 ZPSHF 52 126 08H 09H
.560 ZPSHF 52 142 TSH TSH
.560 ZPSHF 53 13 TSH TSH
.560 ZPSHF 53 141 TSH TSH
.560 ZPSHF 58 104 TEH TSH
.560 ZPSHF 58 104 TEH TSH
.560 ZPSHF 58 136 TSH TSH
.560 ZPSHF 58 142 TSH TSH
.560 ZPSHF 61 13 TSH TSH
.560 ZPSHF 61 127 TEH TSH
.560 ZPSHF 61 141 TSH TSH
.560 ZPSHF 62 54 07H 08H
.560 ZPSHF 64 16 TSH TSH
.560 ZPSHF 64 104 TEH TSH
.560 ZPSHF 64 104 TEH TSH
.560 ZPSHF 64 136 TSH TSH
.560 ZPSHF 64 142 TSH TSH
.560 ZPSHF 65 143 TSH TSH
.560 ZPSHF 66 28 TEH TSH
.560 ZPSHF 66 36 05C 06C
.560 ZPSHF 66 42 01C 02C
.560 ZPSHF 66 42 08C 09C
.560 ZPSHF 68 20 04C 05C
.560 ZPSHF 68 46 03C 04C
.560 ZPSHF 69 47 TEH TSH
.560 ZPSHF 69 141 TSH TSH
.560 ZPSHF 70 16 TSH TSH
.560 ZPSHF 70 136 TSH TSH
.560 ZPSHF 72 24 05C 06C
.560 ZPSHF 72 140 07C 08C
.560 ZPSHF 76 22 TSH TSH
.560 ZPSHF 76 26 01C 02C
.560 ZPSHF 76 28 TEH TSH
.560 ZPSHF 76 130 TSH TSH
.560 ZPSHF 76 136 TSH TSH
.560 ZPSHF 77 21 TSH TSH
.560 ZPSHF 77 31 01C 02C
.560 ZPSHF 77 133 TSH TSH
.560 ZPSHF 77 135 TSH TSH
.560 ZPSHF 78 26 05C 06C
.560 ZPSHF 78 28 02C 03C
.560 ZPSHF 82 22 TSH TSH
.560 ZPSHF 82 130 TSH TSH
.560 ZPSHF 82 136 TSH TSH
.560 ZPSHF 84 92 09C 09C
.560 ZPSHF 84 92 09C 09C
.560 ZPSHF 84 110 TEH TEH
.560 ZPSHF 84 110 TEH TSH
.560 ZPSHF B-4 Appendix B
Tubes Examined By RPC SG-B 84 110 TEH TSH
.560 ZPSHF 84 110 TSH TSH
.560 ZPSHF 85 133 TSH TSH
.560 ZPSHF 86 116 02C 02C
.560 ZPSHF 87 33 01H 02H
.560 ZPSHF 87 33 FBH 01H
.560 ZPSHF 88 28 TSH TSH
.560 ZPSHF 88 110 TEH TSH
.560 ZPSHF 88 124 TSH TSH
.560 ZPSHF 88 130 TSH TSH
.560 ZPSHF 93 29 TSH TSH
.560 ZPSHF 93 111 04C 05C
.560 ZPSHF 93 117 TSH TSH
.560 ZPSHF 93 125 TSH TSH
.560 ZPSHF 94 28 TSH TSH
.1560 ZPSHF 94 118 TSH TSH
.560 ZPSHF 94 124 TSH TSH
.560 ZPSHF 98 30 09C 09C
.560 ZPSHF 98 30 09C 09C
.560 ZPSHF 99 37 09C 09C
.560 ZPSHF 99 37 09C 09C
.560 ZPSHF 100 34 09C 09C
.560 ZPSHF 100 34-09C 09C
.560 ZPSHF 100 34 TSH TSH
.560 ZPSHF 100 118 TSH TSH
.560 ZPSHF 100 124 TSH TSH
.560 ZPSHF 101 37 TSH TSH
.560 ZPSHF 101 67 08C 09C
.560 ZPSHF 101 67 08C 09C
.560 ZPSHF 101 67 08C 09C
.560 ZPSHF 101 117 TSH TSH
.560 ZPSHF 103 35 09C 09C
.560 ZPSHF 103 35 09C 09C
.560 ZPSHF 103 37 09C 09C
.560 ZPSHF 103 37 09C 09C
.560 ZPSHF 104 34 09C 09C
.560 ZPSHF 104 34 09C 09C
.560 ZPSHF 104 36 09C 09C
.560 ZPSHF 104 36 09C 09C
.560 ZPSHF 104 36 09C 09C
.560 ZPSHF 105 37 09C 09C
.560 ZPSHF 105 37 09C 09C
.560 ZPSHF 106 38 09C 09C
.560 ZPSHF 106 38 09C 09C
.560 ZPSHF 106 40 TSH TSH
.560 ZPSHF 106 106 TSH TSH
.560 ZPSHF 106 112 TSH TSH
.560 ZPSHF 106 118 TSH TSH
.560 ZPSHF 109 45 TSH TSH
.560 ZPSHF 109 109 TSH TSH
.560 ZPSHF 109 117 TSH TSH
.560 ZPSHF 110 40 09C 09C
.560 ZPSHF B-5 Appendix B
Tubes Examined By RPC SG-B 110 116 09C 09C
.560 ZPSHF 110 116 09C 09C
.560 ZPSHF 111 43 09C 09C
.560 ZPSHF 111 43 09C 09C
.560 ZPSHF 112 46 TSH TSH
.560 ZPSHF 112 48 09C 09C
.560 ZPSHF 112 48 09C 09C
.560 ZPSHF 112 106 TSH TSH
.560 ZPSHF 112 112 TSH TSH
.560 ZPSHF 113 51 09C 09C
.560 ZPSHF 113 113 09C 09C
.560 ZPSHF 113 113 09C 09C
.560 ZPSHF 114 50 09C 09C
.560 ZPSHF 114 50 09C 09C
.560 ZPSHF 114 108 09C 09C
.560 ZPSHF 114 108 09C 09C
.560 ZPSHF 115 53 01H 02H
.560 ZPSHF 115 53 04H 05H
.560 ZPSHF 115 53 05H 06H
.560 ZPSHF 115 63 TSC FBC
.560 ZPSHF 116 110 09C 09C
.560 ZPSHF 117 53 TSH TSH
.560 ZPSHF 117 101-TSH TSH
.560 ZPSHF 118 52 TSH TSH
.560 ZPSHF 118 58 TSH TSH
.560 ZPSHF 118 100 TSH TSH
.560 ZPSHF 118 106 TSH TSH
.560 ZPSHF 119 77 TSC FBC
.560 ZPSHF 119 103 09C 09C
.560 ZPSHF 119 103 09C 09C
.560 ZPSHF 119 105 09C 09C
.560 ZPSHF 119 105 09C 09C
.560 ZPSHF 120 56 02H 03H
.560 ZPSHF 120 100 09C 09C
.560 ZPSHF 120 104 09C 09C
.560 ZPSHF 122 100 09C 09C
.560 ZPSHF 124 64 TSH FBH
.560 ZPSHF 124 70 TSH TSH
.560 ZPSHF 124 76 TSH TSH
.560 ZPSHF 124 82 TSH TSH
.560 ZPSHF 124 88 TSH TSH
.560 ZPSHF 124 94 TSH TSH
.560 ZPSHF 125 65 09C 09C
.560 ZPSHF 125 69 TSH TSH
.560 ZPSHF 125 77 TSH TSH
.560 ZPSHF 125 85 TSH TSH
.560 ZPSHF 125 89 09C 09C
.560 ZPSHF 125 93 TSH TSH
.560 ZPSHF 126 72 02C 02C
.560 ZPSHF 126 72 02C 03C
.560 ZPSHF 126 72 09C 09C
.560 ZPSHF 126 78 09C 09C
.560 ZPSHF B-6 Appendix B
Tubes Examined By RPC SG-B 126 84 09C 09C
.560 ZPSHF 126 86 09C 09C
.560 ZPSHF 126 86 09C 09C
.560 ZPSHF 127 69 09C 09C
.560 ZPSHF 127 75 09C 09C
.560 ZPSHF 127 81 09C 09C
.560 ZPSHF 127 87 09C 09C
.560 ZPSHF B-7 Appendix B N
Tube Examined By RPC SG-C ROW COL BEGIN TEST END TEST PROBE 2
50 09C 09H
.520 ZPUMB 2
54 TSH TSH
.560 ZPSHF 2
58 TSH TSH
.560 ZPSHF 2
62 TSH TSH
.560 ZPSHF 2
66 TSH TSH
.560 ZPSHF 2
86 TSH TSH
.560 ZPSHF 2
90 TSH TSH
.560 ZPSHF 2
94 TSH TSH
.560 ZPSHF 2
98 TSH TSH
.560 ZPSHF 2
102 TSH TSH
.560 ZPSHF 3
53 TSH TSH
.560 ZPSHF 3
63 TSH TSH
.560 ZPSHF 3
93 TSH TSH
.560 ZPSHF 3
103 TSH TSH
.560 ZPSHF 4
4 TSH TSH
.560 ZPSHF 4
60 TSH TSH
.560 ZPSHF 4
154 TSH TSH
.560 ZPSHF 5
3 TEH TSH
.560 ZPSHF 5
147 04C 05C
.560 ZPSHF 6
54 TSH TSH
.560 ZPSHF 6
58 TSH TSH
.560 ZPSHF 6
62 TSH TSH
.560 ZPSHF 6
66 TSH TSH
.560 ZPSHF 6
86 TSH TSH
.560 ZPSHF 6
90 TSH TSH
.560 ZPSHF 6
94 TSH TSH
.560 ZPSHF 6
98 TSH TSH
.560 ZPSHF 6
100 TSH TSH
.560 ZPSHF 6
102 TSH TSH
.560 ZPSHF 6
108 06C 07C
.560 ZPSHF 6
152 TSH TSH
.560 ZPSHF 8
58 TSH TSH
.560 ZPSHF 8
88 TSH TSH
.560 ZPSHF 8
98 TSH TSH
.560 ZPSHF 8
154 05C 06C
.560 ZPSHF 10 4
TSH TSH
.560 ZPSHF 10 54 TSH TSH
.560 ZPSHF 10 58 TSH TSH
.560 ZPSHF 10 62 TSH TSH
.560 ZPSHF 10 66 TSH TSH
.560 ZPSHF 10 86 TSH TSH
.560 ZPSHF 10 90 TSH TSH
.560 ZPSHF 10 94 TSH TSH
.560 ZPSHF 10 98 TSH TSH
.560 ZPSHF 10 102 TSH TSH
.560 ZPSHF 10 154 TSH TSH
.560 ZPSHF 11 43 06C 07C
.560 ZPSHF 13 63
.560 ZPSHF 13 63 TSH TSH
.560 ZPSHF 13 93 TSH TSH
.560 ZPSHF 13 151 TSH TSH
.560 ZPSHF B-1 Appendix B
Tube Examined By RPC SG-C 14 58 TSH TSH
.560 ZPSHF 14 62 TSH TSH
.560 ZPSHF 14 66 TSH TSH
.560 ZPSHF 14 86 TSH TSH
.560 ZPSHF 14 88 TSH TSH
.560 ZPSHF 14 90 TSH TSH
.560 ZPSHF 14 94 TSH TSH
.560 ZPSHF 14 98 TSH TSH
.560 ZPSHF 14 132 02C 03C
.560 ZPSHF 14 150 06C 06C
.560 ZPSHF 15 117 08C 09C
.560 ZPSHF 16 4
TSH TSH
.560 ZPSHF 16 154 TSH TSH
.560 ZPSHF 18 58 TSH TSH
.560 ZPSHF 18 62 TSH TSH
.560 ZPSHF 18 66 TSH TSH
.560 ZPSHF 18 86 TSH TSH
.560 ZPSHF 18 88 TSH TSH
.560 ZPSHF 18 90 TSH TSH
.560 ZPSHF 18 94 TSH TSH
.560 ZPSHF 18 98 TSH TSH
.560 ZPSHF 19 49 03C 04C
.560 ZPSHF 19 127 09H 09H
.560 ZPSHF 20 40 FBC 01C
.560 ZPSHF 20 130 09C 09C
.560 ZPSHF 20 130 09H 09H
.560 ZPSHF 21 77 08C 09C
.560 ZPSHF 21 115 05C 05C
.560 ZPSHF 21 149 TSH TSH
.560 ZPSHF 22 4
TSH TSH
.560 ZPSHF 22 58 TSH TSH
.560 ZPSHF 22 62 TSH TSH
.560 ZPSHF 22 66 TSH TSH
.560 ZPSHF 22 70 TSH TSH
.560 ZPSHF 22 74 TSH TSH
.560 ZPSHF 22 78 TSH TSH
.560 ZPSHF 22 82 TSH TSH
.560 ZPSHF 22 86 TSH TSH
.560 ZPSHF 22 90 TSH TSH
.560 ZPSHF 22 94 TSH TSH
.560 ZPSHF 22 98 TSH TSH
.560 ZPSHF 22 148 TSH TSH
.560 ZPSHF 23 63 TSH TSH
.560 ZPSHF 23 73 TSH TSH
.560 ZPSHF 23 77 TSH TSH
.560 ZPSHF 23 83 TSH TSH
.560 ZPSHF 23 93 TSH TSH
.560 ZPSHF 24 130 08C 09C
.560 ZPSHF 25 57 03C 04C
.560 ZPSHF 26 62 TSH TSH
.560 ZPSHF 26 66 08C 09C
.560 ZPSHF 26 66 TSH TSH
.560 ZPSHF B-2 Appendix B
Tube Examined By RPC SG-C 26 70 TSH TSH
.560 ZPSHF 26 74 TSH TSH
.560 ZPSHF 26 78 TSH TSH
.560 ZPSHF 26 82 TSH TSH
.560 ZPSHF 26 86 TSH TSH
.560 ZPSHF 26 90 TSH TSH
.560 ZPSHF 26 94 TSH TSH
.560 ZPSHF 26 148 TSH TSH
.560 ZPSHF 28 4
TSH TSH
.560 ZPSHF 28 68 TSH TSH
.560 ZPSHF 28 78 TSH TSH
.560 ZPSHF 28 88 TSH TSH
.560 ZPSHF 28 148 TSH TSH
.560 ZPSHF 28 152 08C 09C
.560 ZPSHF 28 152 08C 09C
.560 ZPSHF 28 152 08C 09C
.560 ZPSHF 29 5
TSH TSH
.560 ZPSHF 29 149 TSH TSH
.560 ZPSHF 30 66 TSH TSH
.560 ZPSHF 30 70 TSH TSH
.560 ZPSHF 30 74 TSH TSH
.560 ZPSHF 30 78 TSH TSH
.560 ZPSHF 30 82 TSH TSH
.560 ZPSHF 30 86 TSH TSH
.560 ZPSHF 30 90 TSH TSH
.560 ZPSHF 30 92 07C 07C
.560 ZPSHF 30 106 07C 08C
.560 ZPSHF 30 106 07H 08H
.560 ZPSHF 30 106 07H 08H
.560 ZPSHF 33 73 TSH TSH
.560 ZPSHF 33 83 TSH TSH
.560 ZPSHF 34 70 TSH TSH
.560 ZPSHF 34 74 TSH TSH
.560 ZPSHF 34 78 TSH TSH
.560 ZPSHF 34 82 TSH TSH
.560 ZPSHF 34 84 TSH TSH
.560 ZPSHF 34 86 TSH TSH
.560 ZPSHF 34 148 TSH TSH
.560 ZPSHF 37 5
TSH TSH
.560 ZPSHF 37 13 0iC 02C
.560 ZPSHF 37 145 08C 09C
.560 ZPSHF 37 145 08C 09C
.560 ZPSHF 37 149 TSH TSH
.560 ZPSHF 38 74 TSH TSH
.560 ZPSHF 38 78 TSH TSH
.560 ZPSHF 38 82 TSH TSH
.560 ZPSHF 39 65 08C 09C
.560 ZPSHF 39 75 06C 06C
.560 ZPSHF 39 121 08H 09H
.560 ZPSHF 39 121 08H 09H
.560 ZPSHF 39 149 TSH TSH
.560 ZPSHF 40 10 TSH TSH
.560 ZPSHF B-3 Appendix B
Tube Examined By RPC SG-C 40 148 TSH TSH
.560 ZPSHF 41 51 07C 08C
.560 ZPSHF 44 16 08C 09C
.560 ZPSHF 44 16 08C 09C
.560 ZPSHF 44 16 08C 09C
.560 ZPSHF 44 16 08C 09C
.560 ZPSHF 44 16 08C 09C
.560 ZPSHF 44 16 08H 09H
.560 ZPSHF 44 16 08H 09H
.560 ZPSHF 44 16 08H 09H
.560 ZPSHF 45 149 TSH TSH
.560 ZPSHF 46 10 TSH TSH
.560 ZPSHF 46 92 FBH 01H
.560 ZPSHF 46 148 TSH TSH
.560 ZPSHF 48 26 02C 02C
.560 ZPSHF 48 66 08C 09C
.560 ZPSHF 48 66 08C 09C
.560 ZPSHF 49 111 05C 06C
.560 ZPSHF 50 54 TEH TSH
.560 ZPSHF 50 54 TEH TSH
.560 ZPSHF 50 54 TEH TSH
.560 ZPSHF 50 54 TEH TSH
.560 ZPSHF 50 84 08C 09C
.560 ZPSHF 52 10 TSH TSH
.560 ZPSHF 52 142 TSH TSH
.560 ZPSHF 53 13 TSH TSH
.560 ZPSHF 53 57 06H 07H
.560 ZPSHF 53 141 TSH TSH
.560 ZPSHF 54 12 TSH TSH
.560 ZPSHF 55 33 07C 08C
.560 ZPSHF 55 57 04H 05H
.560 ZPSHF 55 67 04C 05C
.560 ZPSHF 56 132 05C 05C
.560 ZPSHF 58 14 08H 09H
.560 ZPSHF 58 14 08H 09H
.560 ZPSHF 58 134 TSH TSH
.560 ZPSHF 58 142 TSH TSH
.560 ZPSHF 59 51 TSC FBC
.560 ZPSHF 59 133 FBC 01C
.560 ZPSHF 60 52 08C 09C
.560 ZPSHF 61 13 TSH TSH
.560 ZPSHF 61 65 09H 09H
.560 ZPSHF 61 65 09H 09H
.560 ZPSHF 61 127 02H 03H
.560 ZPSHF 61 141 TSH TSH
.560 ZPSHF 62 58 08C 09C
.560 ZPSHF 64 16 TSH TSH
.560 ZPSHF 64 72 TEH TSH
.560 ZPSHF 64 140 07C 08C
.560 ZPSHF 64 140 09C 09C
.560 ZPSHF 64 142 TSH TSH
.560 ZPSHF 65 13 TSH TSH
.560 ZPSHF B-4 Appendix B
Tube Examined By RPC SG-C 68 16 FBC 01C
.560 ZPSHF 69 17 TSH TSH
.560 ZPSHF 69 141 TSH TSH
.560 ZPSHF 70 16 TSH TSH
.560 ZPSHF 70 116 03H 04H
.560 ZPSHF 70 136 TSH TSH
.560 ZPSHF 71 15 07C 08C
.560 ZPSHF 72 138 09C 09C
.560 ZPSHF 72 138 09C 09C
.560 ZPSHF 74 128 TSH TSH
.560 ZPSHF 74 132 TSH TSH
.560 ZPSHF 75 139 02C 02C
.560 ZPSHF 76 22 TSH TSH
.560 ZPSHF 76 130 TSH TSH
.560 ZPSHF 76 136 09C 09C
.560 ZPSHF 76 136 TSH TSH
.560 ZPSHF 77 21 TSH TSH
.560 ZPSHF 77 133 TSH TSH
.560 ZPSHF 80 132 TSH TSH
.560 ZPSHF 82 22 TSH TSH
.560 ZPSHF 82 130 TSH TSH
.560 ZPSHF 82 136 TSH TSH
.560 ZPSHF 83 21 08C 09C
.560 ZPSHF 83 129 TSH TSH
.560 ZPSHF 84 132 09C 09C
.560 ZPSHF 85 133 TSH TSH
.560 ZPSHF 86 130 TSH TSH
.560 ZPSHF 86 132 09C 09C
.560 ZPSHF 88 28 TSH TSH
.560 ZPSHF 88 124 TSH TSH
.560 ZPSHF 88 130 09C 09C
.560 ZPSHF 88 130 09C 09C
.560 ZPSHF 88 130 TSH TSH
.560 ZPSHF 90 56 07C 08C
.560 ZPSHF 90 70 03C 04C
.560 ZPSHF 90 128 09C 09C
.560 ZPSHF 93 29 TSH TSH
.560 ZPSHF 93 33 01C 02C
.560 ZPSHF 93 91 08C 09C
.560 ZPSHF 93 91 08C 09C
.560 ZPSHF 93 117 TSH TSH
.560 ZPSHF 93 125 08C 08C
.560 ZPSHF 93 125 TSH TSH
.560 ZPSHF 94 28 TSH TSH
.560 ZPSHF 94 114 TEH TSH
.560 ZPSHF 94 118 TSH TSH
.560 ZPSHF 94 124 TSH TSH
.560 ZPSHF 95 117 TSH TSH
.560 ZPSHF 97 71 04C 05C
.560 ZPSHF 98 70 FBH 01H
.560 ZPSHF 100 34 TSH TSH
.560 ZPSHF 100 118 TSH TSH
.560 ZPSHF B-5 Appendix B
Tube Examined By RPC SG-C 100 124 TSH TSH
.560 ZPSHF 101 37 TSH TSH
.560 ZPSHF 101 117 TSH TSH
.560 ZPSHF 102 60 05C 06C
.560 ZPSHF 102 120 09C 09C
.560 ZPSHF 103 55 08H 09H
.560 ZPSHF 103 121 08C 08C
.560 ZPSHF 106 40 TSH TSH
.560 ZPSHF 106 106 TSH TSH
.560 ZPSHF 106 112 TSH TSH
.560 ZPSHF 106 118 TSH TSH
.560 ZPSHF 107 43 TSC FBC
.560 ZPSHF 107 113 09C 09C
.560 ZPSHF 107 113 09C 09C
.560 ZPSHF 107 117 08C 08C
.560 ZPSHF 107 117 08C 08C
.560 ZPSHF 108 50 06H 07H
.560 ZPSHF 108 50 TSH FBH
.560 ZPSHF 108 102 02C 03C
.560 ZPSHF 108 114 08C 08C
.560 ZPSHF 108 114 08C 08C
.560 ZPSHF 108 114 090 09C
.560 ZPSHF 108 118 08C 08C
.560 ZPSHF 108 118 08C 08C
.560 ZPSHF 109 45 TSH TSH
.560 ZPSHF 109 109 TSH TSH
.560 ZPSHF 109 113 08C 08C
.560 ZPSHF 109 113 08C 08C
.560 ZPSHF 109 115 09C 09C
.560 ZPSHF 109 115 09C 09C
.560 ZPSHF 109 117 08C 08C
.560 ZPSHF 109 117 08C 08C
.560 ZPSHF 109 117 TSH TSH
.560 ZPSHF 110 72 02H 03H
.560 ZPSHF 110 110 09C 09C
.560 ZPSHF 110 110 09C 09C
.560 ZPSHF 110 114 08C 08C
.560 ZPSHF 110 114 08C 08C
.560 ZPSHF 110 116 08C 08C
.560 ZPSHF 110 116 08C 08C
.560 ZPSHF 111 55 TEH TSH
.560 ZPSHF 111 55 TSH FBH
.560 ZPSHF 111 107 09C 09C
.560 ZPSHF 111 107 09C 09C
.560 ZPSHF 111 113 09C 09C
.560 ZPSHF 111 113 09C 09C
.560 ZPSHF 112 46 TSH TSH
.560 ZPSHF 112 106 TSH TSH
.560 ZPSHF 112 112 08C 08C
.560 ZPSHF 112 112 08C 08C
.560 ZPSHF 112 112 TSH TSH
.560 ZPSHF 113 111 08C 08C
.560 ZPSHF B-6 Appendix B
Tube Examined By RPC SG-C 113 111 08C 08C
.560 ZPSHF 114 106 09C 09C
.560 ZPSHF 114 108 08C 08C
.560 ZPSHF 114 108 08C 08C
.560 ZPSHF 114 110 08C 08C
.560 ZPSHF 114 110 08C 08C
.560 ZPSHF 115 51 TSH FBH
.560 ZPSHF 115 65 TEH TSH
.560 ZPSHF 116 48 TSH TSH
.560 ZPSHF 116 98 TSH TSH
.560 ZPSHF 116 110 08C 08C
.560 ZPSHF 116 110 08C 08C
.560 ZPSHF 117 53 TSH TSH
.560 ZPSHF 117 55 TEH TSH
.560 ZPSHF 117 55 TSH FBH
.560 ZPSHF 117 101 TSH TSH
.560 ZPSHF 118 52 TSH TSH
.560 ZPSHF 118 58 TSH TSH
.560 ZPSHF 118 72 03H 04H
.560 ZPSHF 118 100 TSH TSH
.560 ZPSHF 118 104 08C 08C
.560 ZPSHF 118 104 08C 08C
.560 ZPSHF 118 106 TSH TSH
.560 ZPSHF 119 55 TEH TSH
.560 ZPSHF 119 55 TSH FBH
.560 ZPSHF 119 105 08C 08C
.560 ZPSHF 119 105 08C 08C
.560 ZPSHF 120 56 09C 09C
.560 ZPSHF 120 56 09C 09C
.560 ZPSHF 120 64 TEH TSH
.560 ZPSHF 120 102 08C 08C
.560 ZPSHF 120 104 TSH TSH
.560 ZPSHF 121 55 09H 09H
.560 ZPSHF 121 55 09H 09H
.560 ZPSHF 121 63 09C 09C
.560 ZPSHF 121 63 09C 09C
.560 ZPSHF 121 99 09C 09C
.560 ZPSHF 121 99 09C 09C
.560 ZPSHF 122 60 TSH TSH
.560 ZPSHF 122 68 TEH TSH
.560 ZPSHF 122 98 09C 09C
.560 ZPSHF 122 98 09C 09C
.560 ZPSHF 123 59 09C 09C
.560 ZPSHF 123 59 09C 09C
.560 ZPSHF 123 63 09C 09C
.560 ZPSHF 123 97 09C 09C
.560 ZPSHF 124 62 09C 09C
.560 ZPSHF 124 64 TSH TSH
.560 ZPSHF 124 70 TSH TSH
.560 ZPSHF 124 76 TSH TSH
.560 ZPSHF 124 78 09C 09C
.560 ZPSHF 124 82 TSH TSH
.560 ZPSHF B-7 Appendix B
Tube Examined By RPC SG-C 124 88 TSH TSH
.560 ZPSHF 124 94 TSH TSH
.560 ZPSHF 125 65 09C 09C
.560 ZPSHF 125 65 09C 09C
.560 ZPSHF 125 69 TSH TSH
.560 ZPSHF 125 75 09C 09C
.560 ZPSHF 125 77 TSH TSH
.560 ZPSHF 125 81 09C 09C
.560 ZPSHF 125 85 TSH TSH
.560 ZPSHF 125 87 09C 09C
.560 ZPSHF 125 91 09C 09C
.560 ZPSHF 125 91 09C 09C
.560 ZPSHF 125 91 09C 09C
.560 ZPSHF 125 93 TSH TSH
.560 ZPSHF 126 66 09C 09C
.560 ZPSHF 126 68 09C 09C
.560 ZPSHF 126 68 09C 09C
.560 ZPSHF 126 72 09C 09C
.560 ZPSHF 126 72 09C 09C
.560 ZPSHF 126 74 09C 09C
.560 ZPSHF 126 74 09C 09C
.560 ZPSHF 126 78 05C 06C
.560 ZPSHF 126 78 07C 08C
.560 ZPSHF 126 78 09C 09C
.560 ZPSHF 126 78 09C 09C
.560 ZPSHF 126 82 09C 09C
.560 ZPSHF 126 84 09C 09C
.560 ZPSHF 126 84 09C 09C
.560 ZPSHF 126 88 09C 09C
.560 ZPSHF 126 88 09C 09C
.560 ZPSHF 127 75 09C 09C
.560 ZPSHF 127 75 09C 09C
.560 ZPSHF B-8 Appendix B
Tube Examined By RPC SG-D ROW COL BEGIN TEST END TEST PROBE 1
115 09H 09C
.520 ZPUMB 1
115 09H 09C
.520 ZPUMB 1
115 09H 09C
.520 ZPUMB 2
22 TEH TSH
.560 ZPSHF 2
32 TEH TSH
.560 ZPSHF 2
36 TEH TSH
.560 ZPSHF 2
54 TSH TSH
.560 ZPSHF 2
56 TEH TSH
.560 ZPSHF 2
58 TSH TSH
.560 ZPSHF 2
62 TSH TSH
.560 ZPSHF 2
66 TSH TSH
.560 ZPSHF 2
86 TSH TSH
.560 ZPSHF 2
88 TSH TSH
.560 ZPSHF 2
90 TSH TSH
.560 ZPSHF 2
94 TSH TSH
.560 ZPSHF 2
98 TSH TSH
.560 ZPSHF 2
102 TSH TSH
.560 ZPSHF 2
110 09H 09C
.520 ZPUMB 3
21 07C 08C
.560 ZPSHF 3
53 TSH TSH
.560 ZPSHF 3
57 07C 08C
.560 ZPSHF 3
63 TSH TSH
.560 ZPSHF 3
93 TSH TSH
.560 ZPSHF 3
103 TSH TSH
.560 ZPSHF 4
4 TSH TSH
.560 ZPSHF 4
40 TEH TSH
.560 ZPSHF 4
60 TSH TSH
.560 ZPSHF 4
154 TSH TSH
.560 ZPSHF 5
27 TEH TSH
.560 ZPSHF 5
31 TEH TSH
.560 ZPSHF 5
153 TEH TSH
.560 ZPSHF 6
54 TSH TSH
.560 ZPSHF 6
58 TSH TSH
.560 ZPSHF 6
62 TSH TSH
.560 ZPSHF 6
66 TSH TSH
.560 ZPSHF 6
86 TSH TSH
.560 ZPSHF 6
90 TSH TSH
.560 ZPSHF 6
94 TSH TSH
.560 ZPSHF 6
98 TSH TSH
.560 ZPSHF 6
100 TSH TSH
.560 ZPSHF 6
102 TSH TSH
.560 ZPSHF 6
148 o1C 02C
.560 ZPSHF 6
152 TSH TSH
.560 ZPSHF 7
59 O1C 02C
.560 ZPSHF 7
59 02C 03C
.560 ZPSHF 8
58 TSH TSH
.560 ZPSHF 8
88 TSH TSH
.560 ZPSHF 8
98 TSH TSH
.560 ZPSHF 8
120 02C 03C
.560 ZPSHF 8
150 FBC 01C
.560 ZPSHF 9
19 TSH FBH
.560 ZPSHF B-1 Appendix B
Tube Examined By RPC SG-D 9
19 TSH FBH
.560 ZPSHF 9
113 FBC 01C
.560 ZPSHF 10 4
TSH TSH
.560 ZPSHF 10 54 FBH 01H
.560 ZPSHF 10 54 TSH TSH
.560 ZPSHF 10 58 TSH TSH
.560 ZPSHF 10 62 TSC 01C
.560 ZPSHF 10 62 TSH TSH
.560 ZPSHF 10 66 TSH TSH
.560 ZPSHF 10 86 TSH TSH
.560 ZPSHF 10 90 TSH TSH
.560 ZPSHF 10 94 TSH TSH
.560 ZPSHF 10 98 TSH TSH
.560 ZPSHF 10 102 TSH TSH
.560 ZPSHF 10 104 FBH O1H
.560 ZPSHF 10 144 03C 04C
.560 ZPSHF 10 154 TSH TSH
.560 ZPSHF 13 63 TSH TSH
.560 ZPSHF 13 93 TSH TSH
.560 ZPSHF 13 151 TSH TSH
.560 ZPSHF 14 58 TSH TSH
.560 ZPSHF 14 62 TSH TSH
.560 ZPSHF 14 66 TSH TSH
.560 ZPSHF 14 86 TSH TSH
.560 ZPSHF 14 88 TSH TSH
.560 ZPSHF 14 90 TSH TSH
.560 ZPSHF 14 94 TSH TSH
.560 ZPSHF 14 98 TSH TSH
.560 ZPSHF 16 4
TSH TSH
.560 ZPSHF 16 154 TSH TSH
.560 ZPSHF 18 58 TSH TSH
.560 ZPSHF 18 62 TSH TSH
.560 ZPSHF 18 66 TSH TSH
.560 ZPSHF 18 82 04C 05C
.560 ZPSHF 18 86 TSH TSH
.560 ZPSHF 18 88 TSH TSH
.560 ZPSHF 18 90 TSH TSH
.560 ZPSHF 18 94 TSH TSH
.560 ZPSHF 18 98 TSH TSH
.560 ZPSHF 19 131 09C 09C
.560 ZPSHF 21 149 TSH TSH
.560 ZPSHF 22 4
TSH TSH
.560 ZPSHF 22 58 TSH TSH
.560 ZPSHF 22 62 TSH TSH
.560 ZPSHF 22 66 TSH TSH
.560 ZPSHF 22 70 TSH TSH
.560 ZPSHF 22 74 TSH TSH
.560 ZPSHF 22 78 TSH TSH
.560 ZPSHF 22 82 TSH TSH
.560 ZPSHF 22 86 TSH TSH
.560 ZPSHF 22 90 TSH TSH
.560 ZPSHF 22 90 TSH TSH
.560 ZPSHF B-2 Appendix B
Tube Examined By RPC SG-D 22 94 TSH TSH
.560 ZPSHF 22 98 TSH TSH
.560 ZPSHF 22 116 TSC FBC
.560 ZPSHF 22 142 TSH TEH
.560 ZPSHF 22 142 TSH TEH
.560 ZPSHF 22 148 TSH TSH
.560 ZPSHF 23 63 TSH TSH
.560 ZPSHF 23 73 TSH TSH
.560 ZPSHF 23 77 TSH TSH
.560 ZPSHF 23 83 TSH TSH
.560 ZPSHF 23 93 TSH TSH
.560 ZPSHF 23 137 09C 09C
.560 ZPSHF 24 88 TSH TSH
.560 ZPSHF 24 94 TSH TSH
.560 ZPSHF 26 62 TSH TSH
.560 ZPSHF 26 66 TSH TSH
.560 ZPSHF 26 70 TSH TSH
.560 ZPSHF 26 74 TSH TSH
.560 ZPSHF 26 78 TSH TSH
.560 ZPSHF 26 82 TSH TSH
.560 ZPSHF 26 86 TSH TSH
.560 ZPSHF 26 90 TSH TSH
.560 ZPSHF 26 94 TSH TSH
.560 ZPSHF 26 148 TSH TSH
.560 ZPSHF 28 4
TSH TSH
.560 ZPSHF 28 68 TSH TSH
.560 ZPSHF 28 78 TSH TSH
.560 ZPSHF 28 88 TSH TSH
.560 ZPSHF 28 148 TSH TSH
.560 ZPSHF 29 5
TSH TSH
.560 ZPSHF 29 117 08H 09H
.560 ZPSHF 29 117 08H 09H
.560 ZPSHF 29 149 TSH TSH
.560 ZPSHF 30 32 01C 02C
.560 ZPSHF 30 64 09C 09C
.560 ZPSHF 30 66 TSH TSH
.560 ZPSHF 30 70 TSH TSH
.560 ZPSHF 30 74 TSH TSH
.560 ZPSHF 30 78 TSH TSH
.560 ZPSHF 30 82 TSH TSH
.560 ZPSHF 30 86 TSH TSH
.560 ZPSHF 30 90 TSH TSH
.560 ZPSHF 30 108 02H 03H
.560 ZPSHF 33 73 TSH TSH
.560 ZPSHF 33 83 TSH TSH
.560 ZPSHF 34 70 TSH TSH
.560 ZPSHF 34 74 TSH TSH
.560 ZPSHF 34 78 TSH TSH
.560 ZPSHF 34 82 TSH TSH
.560 ZPSHF 34 84 TSH TSH
.560 ZPSHF 34 86 TSH TSH
.560 ZPSHF 34 148 TSH TSH
.560 ZPSHF B-3 Appendix B
Tube Examined By RPC SG-D 36 80 08C 09C
.560 ZPSHF 37 5
TSH TSH
.560 ZPSHF 37 11 04C 05C
.560 ZPSHF 37 11 05C 06C
.560 ZPSHF 37 149 TSH TSH
.560 ZPSHF 38 74 TSH TSH
.560 ZPSHF 38 78 TSH TSH
.560 ZPSHF 38 82 TSH TSH
.560 ZPSHF 38 92 04C 05C
.560 ZPSHF 39 149 TSH TSH
.560 ZPSHF 40 10 TSH TSH
.560 ZPSHF 40 148 TSH TSH
.560 ZPSHF 42 108 08H 09H
.560 ZPSHF 43 79 06C 07C
.560 ZPSHF 45 149 TSH TSH
.560 ZPSHF 46 10 TSH TSH
.560 ZPSHF 46 136 09H 09H
.560 ZPSHF 46 148 TSH TSH
.560 ZPSHF 47 145 06C 07C
.560 ZPSHF 48 136 08C 09C
.560 ZPSHF 52 10 TSH TSH
.560 ZPSHF 52 142 TSH TSH
.560 ZPSHF 53 13 TSH TSH
.560 ZPSHF 53 141 TSH TSH
.560 ZPSHF 54 12 TSH TSH
.560 ZPSHF 56 116 08C 08C
.560 ZPSHF 58 136 TSH TSH
.560 ZPSHF 58 142 TSH TSH
.560 ZPSHF 61 13 TSH TSH
.560 ZPSHF 61 141 TSH TSH
.560 ZPSHF 64 16 TSH TSH
.560 ZPSHF 64 136 TSH TSH
.560 ZPSHF 64 142 TSH TSH
.560 ZPSHF 65 13 TSH TSH
.560 ZPSHF 69 17 TSH TSH
.560 ZPSHF 69 19 07H 08H
.560 ZPSHF 69 141 TSH TSH
.560 ZPSHF 70 16 TSH TSH
.560 ZPSHF 70 132 08H 09H
.560 ZPSHF 70 136 TSH TSH
.560 ZPSHF 71 119 02C 03C
.560 ZPSHF 72 136 09C 09C
.560 ZPSHF 74 132 TSH TSH
.560 ZPSHF 76 22 TSH TSH
.560 ZPSHF 76 130 TSH TSH
.560 ZPSHF 76 136 TSH TSH
.560 ZPSHF 77 21 TSH TSH
.560 ZPSHF 77 87 08C 09C
.560 ZPSHF 77 133 TSH TSH
.560 ZPSHF 79 51 08H 09H
.560 ZPSHF 80 132 TSH TSH
.560 ZPSHF 82 22 TSH TSH
.560 ZPSHF B-4 Appendix B
Tube Examined By RPC SG-D 82 126 04C 05C
.560 ZPSHF 82 130 TSH TSH
.560 ZPSHF 82 136 TSH TSH
.560 ZPSHF 83 129 TSH TSH
.560 ZPSHF 85 133 TSH TSH
.560 ZPSHF 86 130 TSH TSH
.560 ZPSHF 87 121 08H 09H
.560 ZPSHF 88 28 TSH TSH
.560 ZPSHF 88 124 TSH TSH
.560 ZPSHF 88 130 TSH TSH
.560 ZPSHF 93 29 TSH TSH
.560 ZPSHF 93 117 TSH TSH
.560 ZPSHF 93 125 TSH TSH
.560 ZPSHF 94 28 TSH TSH
.560 ZPSHF 94 118 TSH TSH
.560 ZPSHF 94 124 TSH TSH
.560 ZPSHF 95 117 TSH TSH
.560 ZPSHF 96 50 08H 09H
.560 ZPSHF 96 50 08H 09H
.560 ZPSHF 97 67 05H 05H
.560 ZPSHF 98 110 02H 03H
.560 ZPSHF 99 121 03H 04H
.560 ZPSHF 100 34 TSH TSH
.560 ZPSHF 100 118 TSH TSH
.560 ZPSHF 100 124 TSH TSH
.560 ZPSHF 101 37 TSH TSH
.560 ZPSHF 101 117 TSH TSH
.560 ZPSHF 104 100 02C 03C
.560 ZPSHF 105 107 07C 08C
.560 ZPSHF 106 40 TSH TSH
.560 ZPSHF 106 104 05C 06C
.560 ZPSHF 106 106 TSH TSH
.560 ZPSHF 106 112 TSH TSH
.560 ZPSHF 106 118 TSH TSH
.560 ZPSHF 108 42 TSC FBC
.560 ZPSHF 109 45 TSH TSH
.560 ZPSHF 109 109 TSH TSH
.560 ZPSHF 109 117 TSH TSH
.560 ZPSHF 112 46 TSH TSH
.560 ZPSHF 112 106 TSH TSH
.560 ZPSHF 112 112 TSH TSH
.560 ZPSHF 116 48 TSH TSH
.560 ZPSHF 116 98 TSH TSH
.560 ZPSHF 117 53 TSH TSH
.560 ZPSHF 117 57 08C 09C
.560 ZPSHF 117 101 TSH TSH
.560 ZPSHF 118 52 TSH TSH
.560 ZPSHF 118 58 TSH TSH
.560 ZPSHF 118 100 TSH TSH
.560 ZPSHF 118 106 TSH TSH
.560 ZPSHF 119 51 08C 09C
.560 ZPSHF 119 51 08C 09C
.560 ZPSHF B-5 Appendix B
Tube Examined By RPC SG-D 119 53 09C 09C
.560 ZPSHF 119 53 09C 09C
.560 ZPSHF 120 104 TSH TSH
.560 ZPSHF 122 60 TSH TSH
.560 ZPSHF 124 64 TSH TSH
.560 ZPSHF 124 70 TSH TSH
.560 ZPSHF 124 76 TSH TSH
.560 ZPSHF 124 82 TSH TSH
.560 ZPSHF 124 88 TSH TSH
.560 ZPSHF 124 94 TSH TSH
.560 ZPSHF 125 69 TSH TSH
.560 ZPSHF 125 77 TSH TSH
.560 ZPSHF 125 85 TSH TSH
.560 ZPSHF 125 93 TSH TSH
.560 ZPSHF B-6 Appendix B
APPENDIX C DENTS AND DINGS
Dents and Dings SG-A ROW COL INDICATION LOCATION CAL NUMBER 1
49 DNG 05C 29.79 46 1
143 DNG 07H 26.24 45 2
98 DNG 09H 9.10 45 2
126 DNG 01H 24.85 45 3
47 DNG 02H 17.01 55 3
85 DNG 08H 3.76 29 3
125 DNG 02C 10.88 64 4
142 DNG 01C 20.16 66 5
99 DNG TSH 20.01 29 6
102 DNG 05C 26.10 64 7
79 DNT Al
.00 88 7
143 DNG TSH 15.41 53 8
84 DNG TSH 32.55 27 8
84 DNG TSH 32.60 53 10 16 DNG FBH 15.01 24 10 16 DNG FBH 15.90 24 10 30 DNG 05C 10.25 30 10 32 DNG 01C 6.04 36 10 50 DNG 02H 3.95 42 10 50 DNG 04H 16.04 42 11 61 DNG 07C 15.37 50 11 61 DNG 08C
-1.62 50 11 71 DNG TSH 16.14 88 11 139 DNG 05C 4.76 53 11 139 DNG 09H 1.35 53 12 32 DNG TSC 1.02 36 12 100 DNG 07C 13.04 29 13 43 DNG A16 5.95 40 13 67 DNG 07C 13.37 58 14 24 DNG 05C 3.14 28 14 36 DNG 02H 17.27 36 14 36 DNG 02H 19.43 36 14 36 DNG A16 5.93 36 14 36 DNG FBH 1.29 36 14 54 DNG A16 5.65 42 14 62 DNG 04C 16.87 56 15 89 DNT A15
.00 25 15 137 DNG 01C 7.37 51 15 137 DNG 08C 38.21 51 16 18 DNG 02H 24.23 22 16 34 DNG 09H 35.72 34 16 36 DNG A16 5.72 36 16 64 DNG 02C 16.13 58 16 146 DNG 08H
-1.90 51 17 11 DNG 09H 7.62 20 17 11 DNG 09H 7.76 16 17 21 DNG 09H 7.28 22 17 49 DNG 07C 10.00 38 17 109 DNG 02H 30.80 35 18 14 DNG 03C 30.70 14 18 134 DNG 02C 20.22 47 C-I Appendix C
Dents and Dings SG-A 19 7
DNG 06H 4.42 20 19 7
DNG 06H 10.78 20 19 55 DNG 06C 5.63 52 19 71 DNG 08C 23.04 88 19 97 DNG 07H 23.42 29 19 125 DNT 09H
-.81 47 20 78 DNG 05C 37.32 88 20 124 DNT 09H
.27 49 21 71 DNG 05C 2.25 62 21 143 DNG 02H 15.10 53 23 19 DNT 03H
-.57 24 23 59 DNG TSC 17.74 52 24 100 DNT 09H
.08 29 24 146 DNG 08H 37.54 51 26 8
DNG 08H 3.40 20 26 68 DNG 08C 37.54 62 26 120 DNT 01H
-.34 41 27 39 DNG TSC 1.19 36 27 61 DNG 08C 34.63 50 27 61 DNG 08H 37.95 50 27 61 DNG 09H
-1.65 50 27 89 DNG A16 2.70 25 27 93 DNT 09C
-.48 25 27 107 DNG 02H 38.44 37 27 149 DNG 06H 7.87 51 29 125 DNG 08H 37.52 47 29 127 DNG 08H 14.94 49 30 44 DNG 07H 33.19 40 31 15 DNG 08H 15.54 24 31 145 DNG 08H 13.67 51 32 4
DNG TSH 8.27 20 32 94 DNT 09C
-.87 23 33 19 DNG 02H 11.54 24 34 134 DNG 05C 7.05 47 34 146 DNG 06H 10.02 51 34 148 DNG 04H 25.25 51 34 148 DNG 04H 25.29 53 35 51 DNT A3
.00 44 35 93 DNG FBC 11.02 25 35 107 DNG 08C 37.63 37 35 119 DNG 04H 34.58 41 35 139 DNG 08H 38.13 53 36 54 DNG 07H 17.83 42 36 56 DNG 09C
-1.93 52 36 144 DNG 08H 34.08 53 37 85 DNT 02C
-.58 21 37 103 DNG 03C 12.04 37 39 145 DNG 08H 25.70 51 40 50 DNG A6 5.67 42 40 92 DNG 08C 37.38 25 40 92 DNG 09H 1.18 25 40 92 DNT 09H
-.74 25 C-2 Appendix C
Dents and Dings SG-A 40 126 DNG A2 4.21 47 40 138 DNG 08H 37.83 51 40 138 DNG 09C
-1.66 51 40 146 DNG 08H 26.91 51 41 45 DNT O1H
-.85 38 41 77 DNG 03C 9.42 60 41 117 DNG 01C 2.94 39 41 145 DNG 08H 31.86 51 43 31 DNG 08C 36.90 32 43 45 DNG 01H 19.64 38 45 143 DNG 08C 32.81 53 46 22 DNG 08C 30.66 22 46 142 DNG 08C 32.78 51 47 13 DNG 08C 8.16 18 47 17 DNG A14
.90 22 47 117 DNG 08C 30.65 39 48 104 DNG 06C 3.30 33 49 31 DNG 08C 31.78 32 49 31 DNG 08C 34.23 32 49 31 DNG 08C 35.05 32 49 39 DNG 09H 12.18 40 49 61 DNG 03H 25.43 50 49 117 DNG 08C 36.36 39 50 120 DNG 05H 25.27 41 50 126 DNG 08C 23.55 47 50 142 DNG 08H 37.75 51 51 131 DNG 08C 18.88 49 52 32 DNG 08H 35.42 36 52 36 DNG 08C 34.46 36 52 142 DNG 08H 29.58 51 53 129 DNG 08C 34.91 47 53 129 DNG 08C 35.17 47 53 129 DNG 08C 36.27 47 54 30 DNG 08C 34.00 30 54 84 DNG 01C 33.53 21 54 90 DNG 07C 2.49 23 54 124 DNG 08C 35.61 49 55 17 DNG 08C 29.17 22 55 17 DNG 09C
-1.97 22 55 29 DNG 02C
-1.50 30 55 29 DNG 04H 22.92 30 55 31 DNG 05H 30.59 32 55 69 DNT FBC
-.13 56 55 101 DNG 03C 1.99 29 56 62 DNG 02H 26.01 56 56 124 DNG 08C 38.37 49 57 33 DNG 04H 14.22 30 58 66 DNG 08C 31.90 56 58 66 DNG 08H 26.85 56 58 66 DNG 08H 35.19 56 58 66 DNT 09H
.43 56 58 74 DNG A6 4.27 60 C-3 Appendix C
Dents and Dings SG-A 58 142 DNG 08H 34.60 51 59 17 DNG FBC 10.29 22 59 17 DNG FBC 14.36 22 59 31 DNG A12 10.92 32 59 45 DNG FBH 13.62 38 59 69 DNG 08H 30.40 56 59 117 DNG 08C 36.03 39 60 30 DNG 08C 24.39 30 60 30 DNG 08C 26.25 30 60 30 DNG 08H 34.76 30 60 30 DNG 09H
-1.42 30 60 30 DNG FBC 3.96 30 60 30 DNT 09C
.34 30 60 48 DNG TSC 5.69 44 60 116 DNG 08H 37.26 41 61 17 DNT A12
-.51 22 61 37 DNG 08H 24.68 34 61 137 DNG 08C 32.41 51 63 13 DNG 08H 12.16 16 63 13 DNG 08H 13.60 16 64 18 DNG 08H 38.28 16 64 18 DNG 09H
-1.47 16 64 28 DNG 03C 26.52 32 64 30 DNG 05C 33.14 30 64 30 DNG 09H
-1.17 30 65 13 DNG 08C 3.12 16 65 13 DNG 08H 4.22 16 65 13 DNG 08H 5.39 16 65 41 DNG FBC 15.37 38 65 71 DNG 03C 16.36 62 66 40 DNG TSH 16.49 40 67 37 DNG 08H 26.60 34 67 109 DNT 09H
.14 35 67 129 DNT FBC
-.44 17 68 84 DNG 07C 32.98 21 68 122 DNT 09C
.39 41 69 19 DNT 09C
.36 14 69 21 DNG 07H 36.15 16 69 73 DNG FBH 3.19 60 70 52 DNG 09H 16.62 44 70 80 DNG A4 10.00 17 70 130 DNG 07C 35.33 17 71 87 DNG TSC 16.77 23 72 86 DNG 01C 6.61 19 72 126 DNG 04C 3.10 17 72 126 DNG 04C 3.17 17 73 125 DNT 09C
.40 17 73 127 DNT 09C
-.56 15 73 137 DNT 09C
-.70 17 74 48 DNT 09H
.46 44 74 106 DNG TSH 11.88 35 74 120 DNG 03C 33.42 41 C-4 Appendix C
Dents and Dings SG-A 76 24 DNT 09C
.38 14 76 48 DNG 08C 27.79 44 76 88 DNG 06C 12.37 21 76 96 DNG A16 2.99 25 77 109 DNG TSC
.74 35 77 133 DNG 07C 22.06 17 78 38 DNG 08C 19.59 34 78 38 DNG 08C 27.64 34 78 38 DNG 08C 30.06 34 78 48 DNG 06C 4.47 44 78 48 DNG 06C 5.56 44 79 31 DNG 02C 36.07 10 79 125 DNG FBC 6.46 53 79 131 DNG 04C 3.39 15 80 20 DNG 08C 24.15 16 80 20 DNT 09C
-.70 16 80 20 DNT 09C
.40 16 80 40 DNT 09H
.47 40 80 84 DNG 02C 32.53 21 80 122 DNG 08H
-1.70 41 80 136 DNT 09C
-.67 15 81 87 DNG TSC 12.07 19 81 115 DNG 05C 34.97 37 81 129 DNT 09C
-.70 17 81 133 DNT 09C
-.69 17 82 126 DNG 03C 18.36 13 82 134 DNG Al5 7.95 17 82 134 DNT 09C
-.75 17 83 77 DNG 08H
-1.27 60 83 91 DNG 02H 11.88 23 83 129 DNT 09C
-.67 13 83 133 DNT 09C
-.67 17 84 86 DNT A4
-.61 19 84 132 DNT 09C
-.61 15 84 132 DNT 09C
.45 15 84 134 DNT 09C
-.75 17 85 31 DNG 02C 5.57 10 85 105 DNG 08C 37.13 33 85 105 DNG 08H 34.55 33 85 109 DNT 09H
.44 35 85 127 DNT 09C
-.64 11 85 133 DNT 09C
-.72 17 86 60 DNG 03C 13.94 58 86 100 DNG 03C 1.55 29 86 132 DNT 09C
-.67 15 86 134 DNT 09C
-.70 17 87 25 DNG 05C 31.68 12 87 127 DNT 09C
-.61 11 88 90 DNG TSC 9.22 23 88 102 DNG 01H 22.29 31 88 128 DNT 09C
-.64 15 88 130 DNT 09C
-.70 17 c-5 Appendix C
Dents and Dings SG-A 88 130 DNT 09C
.45 17 89 31 DNG A7 4.01 10 89 111 DNG 05H 29.36 37 89 125 DNT 09C
-.69 13 89 129 DNT 09C
-.70 13 89 131 DNT 09C
-.70 15 90 128 DNT 09C
-.64 15 90 130 DNT 09C
-.73 17 91 31 DNG 01H 2.70 10 91 127 DNT 09C
-.64 11 92 66 DNG 06C 25.85 56 92 122 DNG 08H 13.76 13 92 124 DNT 09C
-.61 11 92 128 DNT 09C
-.67 15 92 130 DNT 09C
-.75 17 93 85 DNG TSC 7.07 21 93 87 DNG 05C 28.99 19 93 101 DNT 09C
.45 29 93 123 DNT 09C
-.61 11 93 123 DNT 09C
.47 11 93 127 DNT 09C
-.64 11 93 129 DNT 09C
-.75 13 94 128 DNT 09C
-.64 15 95 39 DNG 05H 27.49 10 95 73 DNT FBH
.11 60 95 99 DNG 07H 33.63 27 95 123 DNT 09C
-.64 11 95 125 DNT 09C
-.72 13 95 127 DNT 09C
-.67 11 96 30 DNG FBH 2.14 12 96 124 DNT 09C
-.61 11 96 124 DNT 09C
.45 11 96
-126 DNT 09C
-.67 13 96 128 DNT 09C
-.69 15 97 79 DNG 05H 12.25 19 97 121 DNT 09C
-.70 13 97 123 DNT 09C
-.64 11 97 123 DNT 09C
.45 11 97 125 DNT 09C
-.70 13 97 125 DNT 09C
.40 13 97 127 DNT 09C
-.67 11 98 52 DNG 08C 5.37 44 98 114 DNG 03C 22.56 11 98 124 DNT 09C
-.64 11 98 126 DNT 09C-
-.67 13 98 126 DNT 09C
.43 13 99 31 DNG TSH 7.26 12 99 31 DNG TSH 8.32 12 99 31 DNT 09C
-.63 12 99 31 DNT 09C
.45 12 99 123 DNT 09C
-.64 11 99 123 DNT 09C
.44 11 C-6 Appendix C
Dents and Dings SG-A 99 125 DNT 09C
-.75 13 99 125 DNT 09C
.38 13 100 36 DNG 08C 25.12 10 100 118 DNT 09C
-.69 13 100 118 DNT 09C
.43 13 100 122 DNT 09C
-.73 13 100 122 DNT 09C
.40 13 100 124 DNT 09C
-.67 11 100 124 DNT 09C
.42 11 101 117 DNT 09C
.43 13 101 119 DNT 09C
-.64 11 101 119 DNT 09C
.47 11 101 123 DNT 09C
-.67 11 101 123 DNT 09C
.42 11 102 70 DNG 09H 13.13 60 102 108 DNG 04C 15.80 9
102 108 DNT 04C
.24 9
102 120 DNT 09C
-.67 11 102 120 DNT 09C
.42 11 102 122 DNT 09C
-.72 13 102 122 DNT 09C
.40 13 103 45 DNT 09C
.43 8
103 59 DNG 01H 5.07 52 103 117 DNT 09C
-.73 13 103 117 DNT 09C
.41 13 103 119 DNT 09C
-.61 11 103 119 DNT 09C
.47 11 103 121 DNG FBC 11.04 13 103 121 DNG FBC 11.29 13 103 121 DNT 09C
-.67 13 104 38 DNT 09C
.47 57 104 116 DNT 09C
.38 13 104 116 DNT 09C
.45 11 104 120 DNT 09C
-.70 11 104 122 DNT 09C
-.70 13 104 122 DNT 09C
.40 13 105 113 DNT 09C
-.60 13 105 113 DNT 09C
.49 13 105 115 DNT 09C
-.64 11 105 115 DNT 09C
.45 11 105 117 DNT 09C
-.71 13 105 117 DNT 09C
.43 13 105 119 DNG 08C 32.57 11 105 119 DNT 09C
-.64 11 105 119 DNT 09C
.42 11 105 121 DNT 09C
-.75 13 105 121 DNT 09C
.37 13 106 36 DNG 03C 24.79 10 106 114 DNT 09C
-.64 11 106 116 DNT 09C
.42 11 106 116 DNT 09C
.43 13 106 118 DNT 09C
-.75 13 C-7 Appendix C
Dents and Dings SG-A 106 118 DNT 09C
.40 13 106 120 DNT 09C
-.72 11 106 120 DNT 09C
.39 11 107 93 DNG 04C
-1.68 25 107 101 DNG TSH 5.89 9
107 107 DNG 09H 6.46 7
107 113 DNT 09C
-.68 13 107 113 DNT 09C
.41 13 107 115 DNT 09C
-.69 11 107 115 DNT 09C
.39 11 107 117 DNT 09C
-.76 13 107 117 DNT 09C
.38 13 107 119 DNT 09C
-.70 11 107 119 DNT 09C
.39 11 108 38 DNT AlO
.00 12 108 38 DNT All
.00 12 108 70 DNG A8 10.24 60 108 84 DNG 04C 1.53 57 108 94 DNG 02H 16.26 23 108 110 DNG 07H 21.53 11 108 112 DNT 09C
-.69 13 108 112 DNT 09C
.41 13 108 114 DNT 09C
-.64 11 108 114 DNT 09C
.45 11 108 116 DNT 09C
-.74 13 108 116 DNT 09C
-.64 11 108 116 DNT 09C
.41 13 108 116 DNT 09C
.45 11 108 118 DNT 09C
-.70 13 108 118 DNT 09C
.40 13 109 91 DNG A16 6.79 23 109 101 DNG 01H 24.62 9
109 109 DNG 07H 24.52 9
109 111 DNT 09C
-.62 11 109 113 DNT 09C
-.68 13 109 113 DNT 09C
.44 13 109 115 DNT 09C
-.69 11 109 115 DNT 09C
.42 11 109 117 DNT 09C
-.78 13 109 117 DNT 09C
.38 13 110 110 DNT 09C
-.65 11 110 112 DNT 09C
-.66 13 110 112 DNT 09C
.47 13 110 114 DNT 09C
-.67 11 110 114 DNT 09C
.42 11 110 116 DNG A2 18.91 13 110 116 DNG A2 18.94 11 110 116 DNT 09C
-.71 13 110 116 DNT 09C
-.67 11 110 116 DNT 09C
.39 11 110 116 DNT 09C
.41 13 111 47 DNT 09C
.48 6
C-8 Appendix C
Dents and Dings SG-A 111 61 DNG 08H 31.99 8
111 109 DNT 09C
-.69 9
111 111 DNT 09C
-.67 11 111 111 DNT 09C
.42 11 111 113 DNT 09C
-.68 13 111 113 DNT 09C
.44 13 111 115 DNT 09C
-.69 11 111 115 DNT 09C
.39 11 112 48 DNG 04H 26.95 6
112 48 DNG 05H 32.24 6
112 102 DNG TSC 2.38 7
112 108 DNT 09C
-.64 9
112 108 DNT 09C
.44 9
112 110 DNT 09C
-.65 11 112 110 DNT 09C
.45 11 112 112 DNT 09C
-.74 13 112 112 DNT 09C
.38 13 112 114 DNT 09C
-.67 11 112 114 DNT 09C
.42 11 112 114 DNT A10
-.06 11 113 47 DNT 09C
-.74 6
113 47 DNT 09C
.41 6
113 81 DNT 09C
.48 1
113 101 DNG TSH 5.80 9
113 107 DNT 09C
-.62 7
113 107 DNT 09C
.48 7
113 109 DNT 09C
-.67 9
113 109 DNT 09C
.44 9
113 111 DNT 09C
-.67 11 113 111 DNT 09C
.42 11 113 113 DNT 09C
-.79 13 113 113 DNT 09C
.38 13 113 113 DNT AIO
-.60 13 114 48 DNT 09C
-.69 6
114 48 DNT 09C
.43 6
114 106 DNT 09C
-.64 7
114 106 DNT 09C
.45 7
114 108 DNT 09C
.42 9
114 110 DNT 09C
-.67 11 114 110 DNT 09C
.42 11 114 112 DNT 09C
-.79 13 114 112 DNT 09C
.35 13 115 49 DNT 09C
.40 8
115 101 DNG TSH 5.79 9
115 105 DNT 09C
-.69 9
115 105 DNT 09C
.42 9
115 107 DNT 09C
-.65 7
115 107 DNT 09C
.45 7
115 109 DNT 09C
-.69 9
115 109 DNT 09C
.42 9
115 111 DNT 09C
-.73 11 115 111 DNT 09C
.39 11 C-9 Appendix C
Dents and Dings SG-A 116 46 DNT A5
.25 8
116 46 DNT A5
.56 8
116 50 DNT 09C
.41 8
116 52 DNT 09C
.49 6
116 106 DNT 09C
-.65 7
116 106 DNT 09C
.45 7
116 108 DNT 09C
-.72 9
116 108 DNT 09C
.39 9
116 110 DNT 09C
-.70 11 116 110 DNT 09C
.39 11 117 51 DNT 09C
.46 6
117 61 DNG 09H 23.51 8
117 99 DNT 09C
-.62 7
117 99 DNT 09C
.45 7
117 101 DNT 09C
-.66 9
117 101 DNT 09C
.47 9
117 103 DNT 09C
-.62 7
117 103 DNT 09C
.45 7
117 105 DNG 08C 8.06 9
117 105 DNT 09C
-.75 9
117 105 DNT 09C
.39 9
117 107 DNT 09C
-.67 7
117 107 DNT 09C
.42 7
118 64 DNT 09C
.49 2
118 90 DNT 09C
.50 5
118 100 DNT 09C
-.69 5
118 100 DNT 09C
.44 5
118 102 DNT 09C
-.62 7
118 102 DNT 09C
.42 7
118 104 DNT 09C
-.66 9
118 104 DNT 09C
.44 9
118 106 DNT 09C
-.67 7
118 106 DNT 09C
.42 7
119 51 DNT 09C
.41 6
119 55 DNT 09C
.38 6
119 95 DNT 09C
.45 1
119 97 DNT 09C
.47 1
119 99 DNT 09C
-.67 7
119 99 DNT 09C
.42 7
119 101 DNT 09C
-.66 9
119 101 DNT 09C
.44 9
119 103 DNT 09C
-.65 7
119 103 DNT 09C
.45 7
119 105 DNG 01C 38.29 9
119 105 DNT 09C
-.66 9
119 105 DNT 09C
.44 9
120 52 DNT 09C
-.69 6
120 52 DNT 09C
.43 6
120 54 DNT 09C
.40 8
120 56 DNT 09C
.38 6
120 60 DNT 09C
.52 6
120 62 DNT 09C
.49 4
C-10 Appendix C
Dents and Dings SG-A 120 86 DNT 09C
.51 1
120 88 DNT 09C
-.59 1
120 88 DNT 09C
.51 1
120 92 DNT 09C
.42 1
120 96 DNT 09C
-.70 1
120 96 DNT 09C
.42 1
120 98 DNT 09C
.42 1
120 100 DNT 09C
.38 5
120 102 DNT 09C
-.67 7
120 102 DNT 09C
.42 7
120 104 DNT 09C
-.72 9
120 104 DNT 09C
.41 9
121 59 DNT 09C
.46 6
121 61 DNT 09C
.46 8
121 63 DNT 09C
.46 6
121 79 DNG 05C 3.25 1
121 85 DNT 09C
.48 1
121 87 DNT 09C
.51 1
121 89 DNT 09C
-.67 1
121 89 DNT 09C
.45 1
121 91 DNT 09C
-.62 1
121 91 DNT 09C
.48 1
121 93 DNT 09C
-.61 1
121 93 DNT 09C
.47 1
121 95 DNT 09C
-.69 5
121 95 DNT 09C
.44 5
121 97 DNT 09C
.41 5
121 99 DNT 09C
-.64 7
121 99 DNT 09C
.45 7
121 101 DNT 09C
-.74 9
121 101 DNT 09C
.41 9
122 58 DNT 09C
.46 8
122 60 DNT 09C
.46 6
122 62 DNT 09C
-.64 4
122 62 DNT 09C
.46 4
122 64 DNT 09C
.46 2
122 70 DNT 09C
-.62 4
122 70 DNT 09C
-.60 2
122 70 DNT 09C
.46 4
122 70 DNT 09C
.49 2
122 72 DNG 05H 16.76 2
122 86 DNT 09C
-.62 1
122 86 DNT 09C
.51 1
122 88 DNT 09C
-.67 1
122 88 DNT 09C
.45 1
122 92 DNG 07H 38.23 5
122 92 DNT 09C
-.69 5
122 92 DNT 09C
.44 5
122 94 DNT 09C
.41 5
122 96 DNT 09C
.36 5
122 98 DNT 09C
-.67 1
122 98 DNT 090
.45 1
C-11 Appendix C
Dents and Dings SG-A 122 100 DNT 09C
-.66 5
122 100 DNT 09C
.44 5
123 59 DNT 09C
-.76 6
123 59 DNT 09C
.38 6
123 61 DNT 09C
-.65 8
123 61 DNT 09C
.46 8
123 63 DNT 09C
-.65 6
123 63 DNT 09C
.46 6
123 65 DNT 09C
.46 4
123 67 DNT 09C
.46 2
123 73 DNG TSH 17.49 4
123 79 DNT 09C
.47 5
123 81 DNT 05H
.78 5
123 85 DNT 09C
.44 5
123 87 DNT 09C
-.72 5
123 87 DNT 09C
.44 5
123 89 DNT 09C
.47 5
123 91 DNT 09C
-.66 5
123 91 DNT 09C
.44 5
123 93 DNT 09C
-.66 5
123 93 DNT 09C
.47 5
123 95 DNT 09C
.41 5
123 97 DNT 09C
-.66 5
123 97 DNT 09C
.44 5
124 60 DNT 09C
.44 6
124 62 DNT 09C
.46 4
124 64 DNT 09C
-.66 2
124 64 DNT 09C
.44 2
124 66 DNT 09C
-.63 57 124 66 DNT 09C
.47 57 124 68 DNT 09C
.46 4
124 70 DNG TSH 2.23 2
124 70 DNG TSH 2.25 4
124 72 DNT 09C
-.65 2
124 72 DNT 09C
.49 2
124 74 DNT 09C
.43 57 124 78 DNT 09C
.45 1
124 84 DNT 09C
-.69 5
124 84 DNT 09C
.44 5
124 86 DNT 09C
-.72 5
124 86 DNT 09C
.44 5
124 88 DNT 09C
-.72 5
124 88 DNT 09C
.44 5
124 90 DNG 08H 23.97 5
124 90 DNG 08H 25.07 5
124 90 DNT 09C
-.66 5
124 90 DNT 09C
.44 5
124 92 DNT 09C
-.72 5
124 92 DNT 09C
.42 5
124 94 DNT 09C
-.77 5
124 94 DNT 09C
.38 5
124 96 DNT 09C
-.60 5
C-12 Appendix C
Dents and Dings SG-A 124 96 DNT 09C
.44 5
125 63 DNT 09C
-.68 6
125 63 DNT 09C
.44 6
125 65 DNT 09C
-.67 4
125 65 DNT 09C
.43 4
125 67 DNT 09C
-.66 2
125 67 DNT 09C
.44 2
125 69 DNT 09C
-.65 4
125 69 DNT 09C
.43 4
125 71 DNT 09C
.49 2
125 73 DNT 09C
.46 4
125 75 DNT 09C
.46 2
125 77 DNT 09C
-.67 57 125 77 DNT 09C
.43 57 125 81 DNT 09C
.41 5
125 83 DNT 09C
.45 5
125 85 DNT 09C
-.69 5
125 85 DNT 09C
.44 5
125 87 DNT 09C
-.61 5
125 87 DNT 09C
.50 5
125 89 DNT 09C
-.61 5
125 89 DNT 09C
.47 5
125 91 DNT 09C
-.72 5
125 91 DNT 09C
.41 5
125 93 DNT 09C
-.69 5
125 93 DNT 09C
.44 5
126 66 DNT 09C
-.66 57 126 66 DNT 09C
.47 57 126 68 DNT 09C
-.67 4
126 68 DNT 09C
.43 4
126 70 DNT 09C
-.65 2
126 70 DNT 09C
-.65 4
126 70 DNT 09C
.46 2
126 70 DNT 09C
.46 4
126 72 DNT 09C
-.65 2
126 72 DNT 09C
.46 2
126 74 DNT 09C
-.62 57 126 74 DNT 09C
.46 57 126 78 DNT 09C
-.67 3
126 78 DNT 09C
.44 3
126 80 DNT 09C
.44 5
126 82 DNT 09C
-.61 5
126 82 DNT 09C
.44 5
126 84 DNT 09C
-.69 5
126 84 DNT 09C
.41 5
126 86 DNT 09C
-.72 5
126 86 DNT 09C
.41 5
126 88 DNT 09C
-.72 5
126 88 DNT 09C
.41 5
126 90 DNT 09C
.39 5
127 69 DNT 09C
-.62 4
127 69 DNT 09C
.43 4
C-13 Appendix C
Dents and Dings SG-A 127 71 DNT 09C
-.63 2
127 71 DNT 09C
.44 2
127 71 DNT 09H
-.61 2
127 71 DNT 09H
.50 2
127 73 DNT 09C
-.62 4
127 73 DNT 09C
.46 4
127 75 DNT 09C
-.63 2
127 75 DNT 09C
.46 2
127 77 DNT 09C
-.57 57 127 77 DNT 09C
.46 57 127 79 DNT 09C
-.63 5
127 79 DNT 09C
-.58 5
127 79 DNT 09C
.41 5
127 79 DNT 09C
.49 5
127 81 DNT 09C
-.57 5
127 81 DNT 09C
.49 5
127 83 DNT 09C
-.60 5
127 83 DNT 09C
.47 5
127 85 DNT 09C
-.60 5
127 85 DNT 09C
.44 5
C -14 Appendix C
Dents and Dings SG-B ROW COL INDICATION LOCATION CAL NUMBER 3
101 DNG 05H 1.72 99 3
101 DNG 05H 1.74 117 3
129 DNG 09H 9.18 101 3
129 DNG 09H 9.31 117 4
94 DNG TSC 18.44 108 4
116 DNG 01C 3.76 106 5
17 DNG 02C 7.53 88 5
99 DNG Al
.24 119 5
99 DNG Al
.97 101 6
64 DNG 08H 38.22 26 8
138 DNG 09H 22.57 85 8
148 DNG A16 4.64 97 8
148 DNG A16 4.80 100 10 14 DNG 06C 28.98 82 12 20 DNG 03H 9.33 60 12 56 DNG 06H 17.92 30 12 72 DNG TSC 18.62 141 12 72 DNG TSC 23.70 141 13 7
DNT 09C
-.64 76 14 88 DNT 09C
.53 51 14 138 DNG 07H 2.44 85 16 36 DNG FBH 16.92 48 16 138 DNG A15
-1.78 81 16 138 DNG A15
-1.78 83 17 137 DNG TSH 12.08 83 17 143 DNG 08H 38.07 95 17 143 DNG 09H
-2.35 98 18 108 DNG TSC 8.92 61 20 30 DNG 03C 2388 54 20 54 DNG FBH 15.02 32 20 104 DNG FBC 12.39 57 20 108 DNT 09C
.58 61 20 108 DNT 09H
-.63 61 21 57 DNG 08C 10.96 30 21 77 DNG TSC 37.83 122 21 127 DNT A3
.96 103 21 131 DNG A16 5.02 73 22 8
DNG 08H 16.08 72 23 141 DNT 09H
.03 89 24 96 DNG 05H 30.77 53 24 120 DNG 08C 36.06 67 24 134 DNG 09C
-1.23 73 25 107 DNG 08C 36.31 63 25 141 DNT 09C
-.11 85 25 141 DNT 09H
-.67 85 26 6
DNG 06C
-1.23 74 26 68 DNG 08C 37.86 22 26 68 DNG 09C
-1.85 22 26 120 DNG 09C
-1.97 67 26 130 DNT 09C
-.22 69 27 31 DNG TSC 18.01 54 C-1 Appendix C
Dents and Dings SG-B 27 93 DNT 09H
-.03 53 28 4
DNG TSC 7.48 74 29 141 DNG 08C 36.79 89 29 141 DNG 08C 36.80 87 29 143 DNG 08C 38.39 94 29 143 DNG 09H
-2.38 95 29 143 DNG 09H
-2.36 94 29 147 DNG 09H 11.76 95 29 147 DNG 09H 16.83 95 30 20 DNG 04C 36.72 60 30 22 DNG 08H 34.02 58 30 86 DNG 08H 33.41 47 30 104 DNG 01C 21.34 57 30 124 DNT 01H
.19 71 30 134 DNT 09C
-.20 73 31 135 DNG 03C 1.31 81 31 141 DNG 08H 35.83 83 31 141 DNG 08H 35.92 89 31 141 DNG 08H 35.93 87 31 141 DNT 09H
-1.27 83 31 141 DNT 09H
-1.19 87 31 141 DNT 09H
-1.19 89 31 143 DNT 09C
-.72 94 32 144 DNG 09H
-1.19 91 33 39 DNG 08C 36.30 46 33 93 DNT 09H
.19 53 33 119 DNG 01C 24.69 65 33 127 DNG 08C 34.73 69 33 141 DNG 08C 37.18 83 34 16 DNG 02H 30.74 64 35 17 DNG 02H 14.40 60 35 81 DNG 08H 37.57 11 35 141 DNG 08C 37.31 83 35 141 DNT 09C
.63 83 35 145 DNG 08H 37.67 94 35 145 DNG 08H 37.67 97 35 145 DNT 09C
.35 97 35 145 DNT 09C
.41 94 35 147 DNG 08H 16.90 95 35 151 DNG TSC 3.15 100 36 24 DNT Al
-.31 56 36 62 DNG 03H 28.69 28 37 49 DNG 08H 38.21 42 37 49 DNG 09H
-1.77 42 37 127 DNG 08C 38.01 69 37 137 DNG 08H 34.58 83 37 141 DNT 09C
-.03 83 37 145 DNT 09H
-.92 97 39 57 DNG 08C 37.31 30 39 99 DNG A12 5.98 59 40 40 DNG TSH 4.65 44 40 96 DNG 07H 37.14 53 C-2 Appendix C
Dents and Dings SG-B 41 87 DNG 08H 36.82 51 43 29 DNG FBH 8.29 56 43 61 DNG TSH 2.32 26 44 28 DNG 08C 33.10 56 44 146 DNG 08C 7.28 100 46 112 DNG 03H 17.91 65 47 25 DNG 01H 10.55 56 47 25 DNG 06C 21.71 56 47 25 DNG 06H 20.40 56 47 57 DNG 09H 22.04 30 47 75 DNG A2 1.68 12 47 147 DNT Al
.39 95 48 18 DNG 05H 2.26 62 48 80 DNG TSH 4.15 9
48 88 DNG 07H 37.15 49 48 104 DNG FBC 14.15 57 48 126 DNG 09C
-1.64 69 49 145 DNT A12 6.40 94 49 145 DNT A12 6.40 97 50 126 DNG 08H 36.41 69 50 126 DNG 08H 37.29 69 50 126 DNT 09C
-.39 69 51 21 DNG 05H 38.35 56 51 79 DNG TSH 4.30 9
52 14 DNG 02H 35.33 66 52 126 DNG 08H 28.15 69 52 126 DNG 08H 33.55 69 52 126 DNG 08H 33.85 69 54 126 DNG 08H 31.73 69 57 95 DNG 08C 21.90 55 58 24 DNG 03H 34.51 68 58 66 DNG FBH 5.45 24 59 81 DNG TSH
.86 11 61 141 DNG 09H 13.04 83 61 143 DNG 09H 1326 94 61 143 DNG 09H 13.26 95 64 52 DNG A12 1.78 34 64 86 DNG A4 3.32 47 65 37 DNG 08H 5.60 48 65 69 DNG 08C 36.93 18 66 36 DNG 05C 22.03 52 67 93 DNG 09C
-1.78 53 67 109 DNG TSH 12.99 61 68 80 DNG 07C 35.44 13 68 136 DNG 07H 18.59 75 70 34 DNG 02H 30.74 54 70 124 DNG TSH 12.88 43 70 128 DNG 08C 34.03 43 71 37 DNG 05H 31.49 48 71 49 DNG 07H 28.17 42 72 24 DNG 05C 18.90 68 72 88 DNG 08C 36.96 23 C-3 Appendix C
Dents and Dings SG-B 72 88 DNG 08C 37.49 23 72 140 DNT A5
.11 47 76 48 DNT 09H
.26 42 77 31 DNG 01C 12.41 54 78 22 DNG 05C 16.34 70 80 90 DNT 03H
.06 21 80 114 DNG 08C 32.01 37 82 78 DNG 08H 33.01 1
84 92 DNT 09C
-.65 23 84 92 DNT 09C
.46 23 84 114 DNG 08C 35.89 37 85 31 DNG 08H 36.03 54 86 72 DNG 03H 4.24 18 86 90 DNG 07H 29.64 21 86 92 DNT 09C
.57 23 86 92 DNT 09H
.32 23 86 116 DNG 02C
-1.22 39 88 32 DNG 03H 36.84 76 88 38 DNG 03H 9.57 50 89 49 DNT 09H
.31 38 89 79 DNG 09H 7.43 9
90 32 DNG 03H 22.33 76 90 64 DNG 05C 4.42 26 92 44 DNG 05C 9.80 44 92 88 DNT 09C
-.74 23 93 111 DNG 04C 17.79 37 94 30 DNG 03H 17.42 78 94 78 DNG TSH 4.22 1
94 106 DNG O1C 25.97 33 94 106 DNG 02C 24.94 33 95 59 DNG 03H 21.72 28 96 72 DNG 02C 30.58 18 96 78 DNG TSH 4.32 1
97 43 DNG 09H 32.96 40 97 89 DNG 05C 20.80 23 98 30 DNT 09C
-.78 78 98 30 DNT 09C
.30 78 98 38 DNG 05H 10.24 50 98 78 DNG TSH 4.18 1
99 31 DNT 09C
-.70 54 99 37 DNT 09C
-.64 48 99 37 DNT 09C
.44 48 99 39 DNT 09C
.40 46 99 59 DNG 08H 31.29 28 99 65 DNG 03H 21.35 26 100 34 DNT 09C
-.72 54 100 34 DNT 09C
.37 54 100 70 DNG 08H 29.77 20 101 67 DNG 08C 31.20 20 101 67 DNG 08C 31.72 20 101 67 DNT 09C
.49 20 102 78 DNG TSH 4.26 1
C-4 Appendix C
Dents and Dings SG-B 102 92 DNT 09C
.52 23 103 35 DNT 09C
-.70 50 103 35 DNT 09C
.38 50 103 37 DNT 09C
-.67 48 103 37 DNT 09C
.42 48 103 53 DNG 04C 18.69 34 103 67 DNG 09H 15.39 20 103 77 DNG 09H 12.29 6
104 34 DNT 09C
-.80 54 104 34 DNT 09C
.32 54 104 36 DNT 09C
-.74 52 104 36 DNT 09C
.36 52 104 48 DNG 01C 4.91 42 104 56 DNG 05H 9.05 34 104 78 DNG TSH 4.24 1
104 92 DNT 09C
.60 23 104 114 DNT 09C
.39 37 105 35 DNT 09C
.32 50 105 37 DNT 09C
-.69 48 105 37 DNT 09C
.39 48 105 39 DNT 09C
.40 46 105 117 DNT 09C
-.63 39 105 117 DNT 09C
.47 39 105 121 DNT 09C
.44 39 106 38 DNT 09C
-.73 50 106 38 DNT 09C
.35 50 106 40 DNT 09C
.53 48 106 116 DNT 09C
.44 39 106 120 DNT 09C
.44 39 107 39 DNT 09C
.32 46 107 43 DNT 09C
-.70 40 107 43 DNT 09C
.38 40 107 117 DNT 09C
.46 39 108 38 DNT 09C
.30 50 108 40 DNT 09C
.33 48 108 42 DNT 09C
.35 46 108 114 DNT 09C
-.64 37 108 114 DNT 09C
.47 37 108 118 DNT 09C
.42 37 109 43 DNT 09C
.35 40 109 111 DNT 09C
.53 37 109 113 DNT 09C
-.65 39 109 113 DNT 09C
.44 39 109 117 DNT 09C
-.68 39 109 117 DNT 09C
.41 39 110 40 DNT 09C
.30 48 110 42 DNG 07H 20.68 46 110 42 DNT 09C
.32 46 110 44 DNG 05H 22.48 44 110 48 DNT 09H
.51 42 110 116 DNT 09C
-.68 39 110 116 DNT 09C
.41 39 C-5 Appendix C
Dents and Dings SG-B ill 43 DNT 09C
-.76 40 111 43 DNT 09C
.32 40 111 51 DNT 09C
.41 36 ill 73 DNG TSH 14.54 8
111 113 DNT 09C
.44 39 111 115 DNT 09C
.39 37 112 48 DNT 09C
-.67 42 112 48 DNT 09C
.45 42 112 48 DNT 09H
.51 42 112 110 DNT 09C
.36 37 112 114 DNT 09C
.41 37 113 51 DNT 09C
.35 36 113 89 DNG 02H 1.56 23 113 113 DNT 09C
-.63 39 113 113 DNT 09C
.46 39 114 48 DNT 09C
.53 42 114 50 DNT 09C
-.71 36 114 50 DNT 09C
.35 36 114 66 DNG 07H 24.19 22 114 108 DNT 09C
-.66 35 114 108 DNT 09C
.46 35 114 112 DNT 09C
.44 39 115 51 DNT 09C
.41 36 115 53 DNG O0H 17.18 34 115 53 DNG 05H 35.42 34 115 73 DNG 02H 2.63 6
115 103 DNT 09C
.47 29 115 111 DNT 09C
.42 37 116 46 DNG 02H 32.42 40 116 50 DNT 09C
.33 36 116 66 DNG 09H
-1.53 22 116 106 DNT 09C
.35 104 116 108 DNT 09C
.44 33 116 110 DNT 09C
.30 37 117 49 DNT 09C
.33 34 117 61 DNG 04H 20.21 26 117 101 DNT 09C
.51 31 117 107 DNT 09C
.42 33 118 50 DNT 09C
.33 36 118 52 DNT 09C
.39 34 118 64 DNT 09C
.39 26 118 88 DNT 09C
.52 23 118 92 DNT 09C
.46 23 118 98 DNT 09C
.44 29 118 102 DNT 09C
.44 29 118 104 DNT 09C
.32 31 118 106 DNT 09C
.44 33 119 77 DNG TSC 14.65 2
119 93 DNT 06H
-.89 27 119 103 DNT 09C
-.64 29 119 103 DNT
-09C
.42 29 119 105 DNT 09C
-.67 31 C-6 Appendix C
Dents and Dings SG-B 119 105 DNT 09C
.32 31 120 56 DNG 02H 6.60 34 120 64 DNT 09C
.39 26 120 92 DNT 09C
.46 23 120 96 DNT 09C
.49 27 120 100 DNT 09C
-.62 31 120 100 DNT 09C
.51 31 120 102 DNT 09C
.33 29 120 104 DNT 09C
.49 31 121 57 DNT 09C
.30 32 121 61 DNT 09C
.39 26 121 63 DNT 09C
.38 28 121 89 DNG 08H 36.34 23 121 91 DNT 09C
.36 25 121 97 DNT 09C
.49 27 121 99 DNT 09C
.44 29 121 101 DNT 09C
.43 31 122 62 DNG 04H 29.40 28 122 64 DNT 09C
.36 26 122 92 DNT 09C
.43 23 122 94 DNT 09C
.42 25 122 96 DNT 09C
.46 27 122 100 DNT 09C
.41 31 123 61 DNT 09C
.36 26 123 65 DNT 09C
.36 26 123 89 DNT 09C
.49 23 123 93 DNT 09C
.46 27 123 95 DNT 09C
.31 25 124 62 DNT 09C
.35 28 124 88 DNT 09C
.52 23 124 92 DNT 09C
.41 23 125 65 DNT 09C
.31 18 125 65 DNT 09C
.36 26 125 75 DNT 09C
.33 4
125 83 DNT 09C
.41 86 125 83 DNT 09C
.44 5
125 85 DNT 09C
.35 86 125 85 DNT 09C
.41 7
125 87 DNT 09C
.42 21 125 89 DNT 09C
-.65 23 125 89 DNT 09C
.43 23 126 68 DNT 09C
.27 8
126 72 DNG 02C 28.34 8
126 72 DNT 09C
.27 8
126 74 DNT 09C
.48 6
126 76 DNT 09C
.31 6
126 78 DNT 09C
.41 1
126 78 DNT 09C
.41 9
126 80 DNT 09C
.30 11 126 84 DNT 09C
.41 11 126 86 DNT 09C
-.63 17 126 86 DNT 09C
.44 17 C-7 Appendix C
Dents and Dings SG-B 126 88 DNT 09C
.46 149 126 90 DNT 09C
.31 21 127 69 DNT 09C
.27 4
127 75 DNT 09C
.30 4
127 77 DNT 09C
.31 2
127 79 DNT 09C
.41 9
127 81 DNT 09C
.41 11 127 85 DNT 09C
.36 95 127 87 DNT 09C
.31 21 C-8 Appendix C
Dents and Dings SG-C ROW COL INDICATION LOCATION CALNUMBER 1
21 DNG 08H 23.44 69 1
25 DNG 07H 35.44 69 2
24 DNT 09H
-.05 67 2
50 DNG 09H 9.59 69 2
72 DNG 08C 27.42 68 2
124 DNG 09C
-1.21 24 3
63 DNG 09H 2.18 61 3
87 DNG A16 1.16 20 4
84 DNG TSC 5.71 74 5
125 DNG 09H 4.93 22 5
129 DNG 09H 5.14 22 5
131 DNG 09H 5.04 20 5
145 DNG 09H 5.09 22 5
147 DNG 04C 4.37 20 6
94 DNT A15
.00 22 6
108 DNG 06C 8.84 20 8
132 DNG 09H 5.51 20 8
134 DNG 09H 5.41 16 8
154 DNG 05C 4.72 10 8
154 DNG 05C 4.83 60 10 86 DNT A2
.00 52 10 104 DNT 06H
-.45 44 11 43 DNG 06C 32.42 27 11 111 DNG FBH 2.02 38 11 135 DNT 09H
-.06 16 13 59 DNG 08C 36.82 41 13 135 DNG 09H 19.54 16 14 104 DNT 09H
-.30 44 14 132 DNG 02C 5.53 22 14 150 DNT 06C
.94 14 15 117 DNG 08C 11.11 40 16 48 DNG 08C 37.34 21 17 41 DNG 09H
-1.08 25 18 46 DNT A15
.05 23 18 118 DNG 08H 36.54 38 18 118 DNT 09H
-.11 38 19 49 DNG 03C 21.49 21 19 49 DNG 03C 21.49 37 19 127 DNT 09H
-.98 20 20 70 DNG 08C 38.30 55 20 130 DNT 09C
-. 19 20 20 130 DNT 09H
.08 20 21 77 DNG 08C 14.17 61 21 115 DNT 05C
.98 38 22 98 DNG 08C 37.18 46 22 98 DNG 08H 37.70 46 22 98 DNT 09H
-.59 46 22 118 DNG A16 2.40 38 24 68 DNG 09C
-1.17 57 24 130 DNG 08C 37.50 20 25 57 DNG 03C 11.76 39 C-1 Appendix C
Dents and Dings SG-C 25 149 DNT 09C
-.56 14 26 34 DNG 08C 6.14 29 26 66 DNG 08C 37.93 51 27 55 DNG 08H 38.33 41 27 151 DNG 08H 36.05 10 27 151 DNT 09C
-.72 10 28 118 DNT 09H
.57 38 28 152 DNG 08C 36.57 8
28 152 DNG 08C 37.53 8
28 152 DNG 08C 38.19 8
29 145 DNG 08H 29.89 14 30 66 DNG 08C 37.80 51 30 88 DNG 08H 38.02 52 30 92 DNT 07C
-.03 48 30 106 DNG 07C 23.94 42 30 106 DNG 07H 22.77 42 30 106 DNG 07H 23.92 42 31 63 DNG 08H 9.34 53 32 22 DNT 09C
-.82 19 32 66 DNG 08H 27.35 51 33 45 DNG 09H 10.22 25 33 79 DNG 09C
-1.51 54 33 79 DNT 09C
-.91 54 33 91 DNT 09H
-1.09 46 35 67 DNT 09H
.27 53 35 121 DNG 01H 33.82 58 36 120 DNG 08C 37.92 40 36 130 DNT 09C
-.72 20 36 134 DNG 01H 37.44 16 36 134 DNG 02H
-1.25 16 37 13 DNG 01C 9.63 13 37 65 DNG 09C
-1.16 51 37 87 DNT 09C
-.97 50 37 89 DNG A6 1.27 52 37 97 DNG 08C 37.85 48 37 97 DNT 09H
-.36 48 37 133 DNG 01H 37.98 22 37 133 DNT 02H
-.67 22 37 145 DNG 08C 35.30 14 37 145 DNT 09C
-1.01 14 39 65 DNG 08C 34.77 51 39 65 DNG 08H 32.47 51 39 75 DNT 06C
-.26 59 39 121 DNG 08H 34.80 60 39 121 DNG 08H 35.46 60 39 121 DNT 09C
.48 60 40 34 DNG 08H 37.97 29 41 51 DNG 07C 30.43 49 42 72 DNG 09H
-1.96 61 42 88 DNT 09H
-1.06 52 43 17 DNG A12 2.72 13 43 125 DNG 09H
-1.26 30 C-2 Appendix C
Dents and Dings SG-C 44 16 DNG 08C 12.16 13 44 16 DNG 08C 14.61 13 44 16 DNG 08C 18.76 13 44 16 DNG 08C 19.83 13 44 16 DNG 08C 20.67 13 44 16 DNG 08H 33.69 13 44 16 DNG 08H 34.75 13 44 16 DNG 08H 35.55 13 45 65 DNG 08H 34.90 51 46 66 DNT 09H
-.39 51 46 92 DNG FBH 14.78 52 48 8
DNT 09H
.92 15 48 26 DNT 02C
-.37 23 48 66 DNG 08C 38.15 51 48 66 DNG 08H 32.27 51 48 66 DNG 09C
-1.91 51 50 60 DNG 04H 30.51 49 50 82 DNG 03H 2.07 54 50 84 DNG 08C 33.91 56 50 104 DNG 08C 38.16 44 50 142 DNG 02C 8.76 8
52 80 DNG 08H 36.48 56 53 57 DNG 06H 31.01 39 53 147 DNT A6
.67 14 55 33 DNG 07C 14.66 29 55 143 DNT 09C
-.66 12 56 66 DNG 09C
-1.88 51 56 130 DNG 08H 37.88 20 56 132 DNT 05C
.27 22 58 14 DNG 08H 38.26 15 58 14 DNG 09H
-1.09 15 58 142 DNT 09C
-.60 8
58 144 DNG 08H 37.07 10 58 144 DNT 09C
-.64 10 59 51 DNG TSC 4.01 45 59 133 DNG FBC 12.67 22 59 145 DNG 08H 36.29 14 60 40 DNG 01H 7.84 27 60 142 DNT 09C
-.63 8
61 65 DNG 09C
-1.48 51 61 65 DNG 09H 1.73 51 61 65 DNT 09H
.63 51 62 58 DNG 08C 7.01 39 63 141 DNT 09C
-.59 10 64 140 DNG 07C 14.46 8
64 140 DNT 09C
-.58 8
65 29 DNT 07H
.37 37 65 141 DNT 09C
-.61 10 66 140 DNT 09C
-.69 8
67 35 DNG 09H 11.82 31 67 35 DNG 09H 11.87 31 67 139 DNT 09C
-.60 8
C-3 Appendix C
Dents and Dings SG-C 67 141 DNT 09C
-.61 10 68 16 DNG FBC 13.60 9
68 138 DNG 08C 4.77 10 68 140 DNT 09C
-.60 8
69 63 DNT A5
.24 53 69 139 DNT 09C
-.63 8
69 141 DNT 09C
-.64 10 70 138 DNT 09C
-.59 10 71 139 DNT 09C
-.60 8
72 138 DNT 09C
-.56 10 72 138 DNT 09C
.51 10 73 137 DNT 09C
-.59 10 74 22 DNT 09H
.43 11 74 136 DNT 09C
-.60 8
74 138 DNT 09C
-.66 10 75 135 DNT 09C
-.68 8
75 139 DNT 02C
.25 8
76 20 DNG A7 1.99 9
76 96 DNG 03H 2.76 48 76 136 DNT 09C
-.60 8
76 138 DNT 09C
-.64 10 77 39 DNT 09C
.61 31 77 135 DNT 09C
-.60 8
77 137 DNT 09C
-.64 10 78 38 DNT 09C
.56 29 78 132 DNT 09C
-.60 8
78 134 DNT 09C
-.59 10 78 136 DNT 09C
-.60 8
79 55 DNG 08C 36.48 41 79 103 DNG 08H 20.28 42 79 131 DNT 09C
-.57 8
79 135 DNT 09C
-.63 8
80 78 DNG A12 4.87 54 80 134 DNT 09C
-.61 10 80 136 DNT 09C
-.63 8
81 129 DNT 09C
-.59 10 81 133 DNT 09C
-.59 10 82 130 DNT 09C
-.56 10 82 134 DNT 09C
-.64 10 83 21 DNG 08C 34.78 11 83 45 DNG 09H
-1.96 25 83 129 DNT 09C
-.61 10 83 131 DNT 09C
-.63 8
83 133 DNT 09C
-.61 10 83 135 DNT 09C
-.63 8
84 130 DNT 09C
-.59 10 84 132 DNT 09C
-.60 8
85 55 DNT FBH
-.82 41 85 129 DNT 09C
-.61 10 85 131 DNT 09C
-.60 8
86 76 DNG TSH 4.03 61 86 128 DNT 09C
-.58 8
C-4 Appendix C
Dents and Dings SG-C 86 130 DNT 08C
-.59 10 86 130 DNT 09C
-.64 10 86 132 DNT 09C
-.63 8
87 127 DNT 09C
-.63 8
87 131 DNT 09C
-.63 8
88 130 DNT 08C
-.61 10 88 130 DNT 09C
-.61 10 88 130 DNT 09C
.48 10 89 129 DNT 09C
-.64 10 89 131 DNT 09C
-.65 8
90 56 DNG 07C 13.02 41 90 70 DNG 03C 17.62 55 90 112 DNG 09H 2.91 44 90 128 DNT 09C
-.60 8
90 130 DNT 09C
-.64 10 91 129 DNT 09C
-.64 10 91 131 DNT 09C
-.65 8
92 56 DNG 08H 32.77 41 92 126 DNT 08C
-.59 10 92 126 DNT 09C
-.64 10 92 128 DNT 09C
-.63 8
93 33 DNG 01C 29.59 9
93 91 DNG 08C 33.04 46 93 91 DNG 09C
-1.77 46 93 123 DNT 09C
-.58 8
93 125 DNT 08C
-.59 10 93 127 DNT 09C
-.60 8
94 124 DNT 09C
-.60 8
94 124 DNT A8
.75 8
94 126 DNT 09C
-.61 10 94 128 DNT 09C
-.68 8
95 121 DNT 09C
-.56 10 95 121 DNT 09C
.51 10 95 123 DNT 09C
-.60 8
95 127 DNT 09C
-.63 8
96 96 DNG TSH 6.14 48 96 126 DNT 09C
-.64 10 97 71 DNG 04C 15.16 55 97 119 DNT 09C
-.61 8
97 119 DNT 09C
.52 8
97 121 DNT 09C
-.61 10 97 123 DNT 08C
-.60 8
97 123 DNT 09C
-.69 8
98 70 DNG FBH 7.90 55 98 118 DNT 09C
-.61 10 99 121 DNT 08C
-.61 10 99 123 DNT 08C
-.60 8
99 123 DNT 09C
-.63 8
99 125 DNT 09C
-.69 10 100 120 DNT 08C
-.65 8
100 122 DNT 09C
-.64 10 101 59 DNT A12
.41 45 C-5 Appendix C
Dents and Dings SG-C 101 119 DNT 09C
-.60 8
101 119 DNT 09C
.46 8
101 121 DNT 09C
-.64 10 101 121 DNT 09C
.45 10 102 60 DNG 05C 34.09 49 102 120 DNT 09C
-.63 8
103 55 DNG 08H 37.69 41 103 107 DNT 09C
.50 4
103 115 DNT 09C
-.57 8
103 115 DNT 09C
.49 8
103 119 DNT 09C
-.63 8
103 121 DNT 08C
-.67 10 104 64 DNT A4
.58 53 104 114 DNT 09C
-.61 10 104 114 DNT 09C
.48 10 104 120 DNT 09C
-.63 8
105 113 DNT 09C
-.61 6
105 113 DNT 09C
.48 6
105 115 DNT 09C
-.63 8
105 115 DNT 09C
.46 8
105 117 DNT 09C
-.64 10 105 117 DNT 09C
.45 10 105 121 DNT 08C
-.67 10 106 64 DNG TSH 14.30 53 106 64 DNG TSH 15.21 53 106 100 DNT 09C
.46 48 106 100 DNT 09C
.47 4
106 114 DNT 08C
-.61 10 106 114 DNT 09C
-.61 10 106 116 DNT 08C
.46 8
106 116 DNT 09C
.49 8
106 118 DNT 09C
-.64 10 106 118 DNT 09C
.45 10 107 43 DNG TSC 10.82 7
107 113 DNT 08C
-.59 6
107 113 DNT 09C
-.61 6
107 113 DNT 09C
.48 6
107 115 DNT 09C
-.60 8
107 115 DNT 09C
.49 8
107 117 DNT 08C
-.64 10 107 117 DNT 08C
.45 10 107 117 DNT 09C
-.64 10 107 117 DNT 09C
.45 10 107 119 DNT 08C
.41 8
108 102 DNG 02C 37.03 6
108 112 DNT 09C
-.63 8
108 114 DNT 08C
-.61 10 108 114 DNT 08C
.43 10 108 114 DNT 09C
-.64 10 108 116 DNT 08C
-.63 8
108 116 DNT 08C
.47 8
108 116 DNT 09C
.44 8
C-6 Appendix C
Dents and Dings SG-C 108 118 DNT 08C
-.67 10 108 118 DNT 08C
.43 10 108 118 DNT 09C
-.67 10 109 111 DNT 08C
-.61 4
109 111 DNT 09C
-.60 4
109 111 DNT 09C
.49 4
109 113 DNT 08C
-.61 6
109 113 DNT 08C
.45 6
109 113 DNT 09C
-,64 6
109 113 DNT 09C
.48 6
109 115 DNT 08C
.46 8
109 115 DNT 09C
-.63 8
109 115 DNT 09C
.46 8
109 117 DNG A12 5.54 10 109 117 DNG A12 10.74 10 109 117 DNT 08C
-.67 10 109 117 DNT 08C
.43 10 109 117 DNT A12
.61 10 110 72 DNG 02H 6.12 57 110 108 DNT 09C
-.60 4
110 110 DNT 08C
-.61 6
110 110 DNT 09C
-.61 6
110 110 DNT 09C
.48 6
110 112 DNT 08C
-.58 8
110 112 DNT 08C
.44 8
110 112 DNT 09C
-.66 8
110 114 DNT 08C
-.64 10 110 114 DNT 08C
.45 10 110 114 DNT 09C
-.61 10 110 114 DNT 09C
.45 10 110 116 DNT 08C
-.78 2
110 116 DNT 08C
-.69 8
110 116 DNT 08C
.29 2
110 116 DNT 08C
.44 8
110 116 DNT 09C
-.78 2
110 116 DNT 09C
-.63 8
111 47 DNG 09H 8.59 7
111 49 DNG 05H 5.66 5
111 107 DNT 09C
-.60 4
111 107 DNT 09C
.49 4
111 109 DNT 08C
-.61 6
111 111 DNT 08C
-.61 4
111 111 DNT 08C
.47 4
111 111 DNT 09C
-.66 4
111 113 DNT 08C
-.64 6
111 113 DNT 08C
.45 6
111 113 DNT 09C
-.64 6
111 113 DNT 09C
.45 6
111 115 DNT 09C
-.68 8
111 115 DNT 09C
.44 8
112 98 DNT 09H
-1.24 6
112 102 DNG FBH 1.24 6
C-7 Appendix C
Dents and Dings SG-C 112 104 DNT 09C
.49 4
112 106 DNT 09C
.48 6
112 110 DNT 08C
-.61 6
112 110 DNT 08C
.40 6
112 112 DNT 08C
-.60 8
112 112 DNT 08C
.47 8
112 112 DNT 09C
-.63 8
112 112 DNT 09C
.47 8
112 114 DNT 08C
-.69 10 112 114 DNT 09C
-.69 10 113 71 DNG 08H 38.14 3
113 99 DNG 08H 38.01 4
113 105 DNT 09C
-.61 6
113 105 DNT 09C
.48 6
113 107 DNT 09C
-.69 4
113 107 DNT 09C
.50 4
113 109 DNT 08C
-.62 6
113 109 DNT 08C
.43 6
113 111 DNT 08C
-.64 4
113 111 DNT 08C
.44 4
113 111 DNT 09C
-.66 4
113 111 DNT 09C
.44 4
113 113 DNT 08C
-.67 6
113 113 DNT 09C
-.67 6
113 113 DNT 09C
.43 6
114 48 DNT 09C
.49 5
114 48 DNT 09C
.49 7
114 104 DNT 09C
-.61 4
114 104 DNT 09C
.50 4
114 106 DNT 09C
.45 6
114 108 DNT 08C
-.61 4
114 108 DNT 08C
.44 4
114 108 DNT 09C
-.63 4
114 110 DNT 08C
-.64 6
114 110 DNT 08C
.46 6
114 110 DNT 09C
-.64 6
114 110 DNT 09C
.43 6
114 112 DNT 08C
-.63 8
115 47 DNT 09C
-.67 7
115 47 DNT 09C
.47 7
115 105 DNT 09C
-.64 6
115 105 DNT 09C
.45 6
115 107 DNT 08C
-.69 4
115 107 DNT 08C
.44 4
115 109 DNT 08C
.46 6
115 109 DNT 09C
-.64 6
115 109 DNT 09C
.43 6
115 111 DNT 08C
-.67 4
115 111 DNT 09C
-.66 4
116 104 DNT 08C
-.69 4
116 104 DNT 09C
.47 4
116 106 DNT 08C
-.64 6
C-8 Appendix C
Dents and Dings SG-C 116 106 DNT 09C
-.64 6
116 108 DNT 08C
-.61 4
116 108 DNT 09C
-.63 4
116 108 DNT 09C
.44 4
116 110 DNT 08C
-.78 2
116 110 DNT 08C
-.67 6
117 49 DNT 09C
.44 7
117 55 DNT 09C
.48 7
117 105 DNT 09C
-.61 6
117 105 DNT 09C
.45 6
117 107 DNT 08C
-.64 4
117 107 DNT 09C
-.63 4
117 107 DNT 09C
.44 4
118 96 DNT 09C
.50 4
118 102 DNT 09C
.45 6
118 104 DNT 08C
-.64 4
118 104 DNT 08C
.44 4
118 104 DNT 09C
-.63 4
118 104 DNT 09C
.47 4
119 55 DNT 09C
.49 7
119 59 DNT 09C
.44 3
119 83 DNT 09C
.52 4
119 93 DNT 09C
.48 6
119 95 DNT 09C
.50 4
119 99 DNT 09C
.47 4
119 101 DNT 08C
.43 6
119 101 DNT 09C
.45 6
119 103 DNT 08C
.44 4
119 105 DNT 08C
-.66 6
119 105 DNT 08C
.43 6
119 105 DNT 09C
.45 6
120 56 DNT 09C
-.63 5
120 56 DNT 09C
.48 5
120 60 DNT 09C
.48 5
120 96 DNT 08C
.47 4
120 98 DNT 09C
.45 6
120 100 DNT 08C
.44 4
120 100 DNT 09C
.44 4
120 102 DNT 08C
.45 6
120 102 DNT 09C
.45 6
121 55 DNT 09H
-.60 7
121 55 DNT 09H
.52 7
121 57 DNT 09C
.45 5
121 59 DNT 09C
.45 3
121 63 DNT 09C
-.63 3
121 63 DNT 09C
.45 3
121 87 DNT 09C
.49 4
121 93 DNT 09C
.48 6
121 97 DNT 08C
.45 6
121 99 DNT 09C
-.61 4
121 99 DNT 09C
.47 4
121 101 DNT 09C
.45 6
C-9 Appendix C
Dents and Dings SG-C 122 56 DNT 09C
.34 2
122 56 DNT 09C
.43 7
122 60 DNT 09C
.45 5
122 88 DNT 09C
.50 54 122 96 DNT 08C
.43 4
122 96 DNT 09C
.43 4
122 98 DNT 09C
-.63 6
122 98 DNT 09C
.45 6
123 59 DNT 09C
-.67 3
123 59 DNT 09C
.45 3
123 61 DNT 09C
-.64 1
123 61 DNT 09C
.42 1
123 63 DNT 09C
.42 3
123 65 DNT 09C
.44 1
123 67 DNT 09C
.49 58 123 77 DNT 09C
.46 1
123 79 DNT 09C
.49 4
123 83 DNT 09C
.47 4
123 89 DNT 09C
.48 6
123 91 DNT 09C
.47 4
123 95 DNT 09C
.47 4
123 97 DNT 09C
.45 6
124 62 DNT 09C
.45 3
124 64 DNT 09C
-.61 1
124 64 DNT 09C
.49 1
124 64 DNT 09H
.49 1
124 66 DNT 09C
.49 58 124 68 DNT 09C
-.64 1
124 68 DNT 09C
.44 1
124 76 DNT 09C
.46 1
124 78 DNT 09C
.49 4
124 80 DNT 09C
.48 6
124 82 DNT 09C
.49 4
124 86 DNT 09C
.47 6
124 88 DNT 09C
.47 54 124 90 DNT 09C
.46 4
124 92 DNG A10 13.15 6
124 92 DNG A10 13.31 4
124 92 DNT 08C
.43 6
124 92 DNT 08C
.44 4
124 94 DNT 09C
.43 6
124 96 DNT 08C
-.73 2
124 96 DNT 08C
-.69 4
124 96 DNT 08C
.32 2
124 96 DNT 08C
.33 4
125 63 DNT 09C
.42 3
125 65 DNT 09C
.39 2
125 65 DNT 09C
.44 1
125 65 DNT 09C
.49 2
125 69 DNT 09C
.44 1
125 71 DNT 09C
.44 3
125 73 DNT 09C
.44 1
C-10 Appendix C
Dents and Dings SG-C 125 75 DNT 09C
.42 3
125 77 DNT 09C
.46 1
125 79 DNT 09C
.49 4
125 81 DNT 09C
.45 6
125 83 DNT 09C
.47 4
125 85 DNT 08C
.45 6
125 85 DNT 09C
.45 6
125 87 DNT 09C
.46 4
125 89 DNT 08C
.43 6
125 91 DNT 09C
-.72 4
125 91 DNT 09C
-.62 2
125 91 DNT 09C
.44 4
125 91 DNT 09C
.47 2
126 66 DNT 09C
.47 58 126 68 DNT 09C
-.67 1
126 68 DNT 09C
.41 1
126 70 DNT 09C
.44 3
126 72 DNT 09C
-.71 2
126 72 DNT 09C
-.67 1
126 72 DNT 09C
.37 2
126 72 DNT 09C
.41 1
126 74 DNT 09C
-.65 3
126 74 DNT 09C
.44 3
126 76 DNT 09C
.41 1
126 78 DNG 05C 8.80 2
126 78 DNG 05C 8.85 4
126 78 DNG 07C 23.05 2
126 78 DNG 07C 23.11 4
126 78 DNT 09C
-.63 4
126 78 DNT 09C
-.59 2
126 78 DNT 09C
.46 4
126 78 DNT 09C
.50 2
126 80 DNT 09C
.48 6
126 82 DNT 09C
.43 4
126 84 DNT 09C
-.64 4
126 84 DNT 09C
-.64 6
126 84 DNT 09C
-.59 2
126 84 DNT 09C
.45 6
126 84 DNT 09C
.48 4
126 84 DNT 09C
.49 2
126 86 DNT 09C
.44 6
126 88 DNT 09C
-.60 54 126 88 DNT 09C
.46 54 127 69 DNT 09C
-.62 2
127 69 DNT 09C
-.60 3
127 69 DNT 09C
.42 3
127 69 DNT 09C
.49 2
127 71 DNT 09C
.41 1
127 73 DNT 09C
.44 1
127 75 DNT 09C
-.74 2
127 75 DNT 09C
-.63 3
127 75 DNT 09C
.34 2
C-1l Appendix C
Dents and Dings SG-C 127 75 DNT 09C
.42 3
127 77 DNT 09C
-.67 1
127 77 DNT 09C
.44 1
127 79 DNT 08C
.46 4
127 79 DNT 09C
.44 4
127 85 DNT 09C
.45 6
C-12 Appendix C
Dents and Dings SG-D ROW COL INDICATION LOCATION CAL NUMBER 1
11 DNT 09H
.29 91 1
115 DNG 09H 2.57 117 1
115 DNT 09H
.59 117 1
115 DNT 09H
.62 117 2
110 DNG Al 5.25 117 3
21 DNG 07C 34.29 108 3
25 DNG 09H 9.07 89 3
93 DNG 09C 2.55 124 4
16 DNG 02H 7.88 89 4
16 DNG TSH 17.05 89 5
97 DNG 09C 3.20 124 6
36 DNT 09H
-1.00 60 6
86 DNG A16
-1.13 83 6
148 DNG 01C 7.95 83 7
59 DNG 0IC 16.81 93 7
59 DNG 0IC 16.96 88 8
150 DNG FBC 10.70 81 9
19 DNG TSH 9.32 50 9
19 DNG TSH 10.52 50 9
113 DNG FBC 7.72 53 10 54 DNG FBH 14.57 93 10 54 -
DNG FBH 14.70 109 10 62 DNG TSC
.96 92 10 104 DNG FBH 14.59 47 10 144 DNG 03C 18.36 83 12 114 DNG TSH 3.02 65 12 140 DNG 09H 10.97 79 13 79 DNG A2 2.25 136 14 104 DNG 09H 36.70 47 15 137 DNG 01H 38.04 77 16 58 DNG 09H 3.83 88 16 68 DNG 09H 4.13 94 17 153 DNG A2
-1.30 81 18 82 DNG 04C 36.85 83 18 142 DNG 09C
-1.53 81 19 131 DNT 09C
-.83 71 20 74 DNG 08H 36.78 105 22 76 DNG 08C 37.43 103 22 116 DNG TSC 3.30 59 23 137 DNG 09H
-2.00 77 23 137 DNT 09C
-.69 77 24 152 DNG FBC 16.33 83 25 137 DNG 09C
-1.30 77 26 138 DNG 09C
-1.78 77 26 138 DNT 09H
-.42 77 27 61 DNG 07C 33.74 88 27 65 DNT 09H
-1.00 92 27 117 DNT 09H
-1.10 69 27 123 DNG 08H 37.68 67 28 120 DNG 03C 34.71 67 29 63 DNG 09C
-1.45 86 C-1 Appendix C
Dents and Dings SG-D 29 89 DNG 02H 14.14 31 29 117 DNG 08H 20.96 69 29 117 DNG 08H 32.54 69 30 64 DNT 09C
-.82 90 30 108 DNG 02H 8.08 51 31 55 DNG 08H 35.13 76 31 119 DNT 09C
.00 63 32 62 DNG 02C 38.37 92 32 116 DNG 08C 38.04 59 32 116 DNG 08H 39.13 59 33 85 DNG 01C 21.20 27 33 137 DNT 09C
.32 77 35 51 DNG A16 4.91 72 35 79 DNG 08H 30.94 25 35 81 DNG 08C 37.95 27 36 80 DNG 08C 37.73 27 37 11 DNG 05C 15.67 34 37 11 DNG 05C 15.74 40 37 117 DNG 09C
-1.68 65 38 62 DNG 08C 38.22 92 38 88 DNG 08H 36.00 31 38 92 DNG 04C 12.37 35 39 37 DNG 07C 36.11 62 40 108 DNG 08H 27.75 51 40 108 DNG 08H 28.04 51 40 108 DNG 08H 37.44 51 42 108 DNG 08H 33.93 51 42 136 DNG 08C 37.91 79 43 125 DNT 09H
.15 69 44 68 DNG 04H 22.39 94 45 79 DNT 05H
.78 25 46 118 DNG A16 12.51 65 46 136 DNG 09H
-1.18 79 46 144 DNG 08H 35.55 79 47 145 DNG 06C 35.79 81 48 136 DNG 08C 31.06 79 49 113 DNG 01H 13.49 53 50 8
DNT A5
.00 40 50 108 DNT 08H 1.00 51 50 148 DNT A6
.27 83 51 125 DNT 09H
-.73 69 52 78 DNG 08H 34.08 25 54 88 DNG 09H 13.32 31 55 103 DNG 01C 31.80 47 56 50 DNG 01H 6.93 74 56 100 DNG A6 2.57 47 56 116 DNT 08C
-.66 59 58 92 DNG 09H
-1.43 35 58 100 DNG A2 5.09 47 59 101 DNT A4
.76 45 61 131 DNG 08H 39.32 71 66 66 DNG 02H 12.29 96 C-2 Appendix C
Dents and Dings SG-D 66 138 DNG 03H
-1.26 15 67 121 DNG A8 11.51 65 69 19 DNG 07H 13.73 30 69 77 DNG 02C 1.34 105 70 132 DNG 08H 36.27 13 71 115 DNG 05H 38.88 55 71 115 DNG 06H 2.37 55 71 119 DNG 02C 24.90 63 72 86 DNG 01H 34.05 29 72 136 DNT 09C
-.62 13 75 139 DNT A6
.00 15 75 139 DNT A6
.00 85 77 29 DNG TSC 16.25 6
79 49 DNG 04H 15.85 74 79 51 DNG 08H 37.17 72 80 104 DNG 07C 36.47 51 81 121 DNT Al
.02 65 82 20 DNG 03H 2.40 6
82 54 DNT 09C
.44 82 82 126 DNG 04C 21.28 15 83 63 DNG 01H 33.17 86 83 111 DNG A16 13.92 55 83 135 DNT 05H
.61 15 85 61 DNG 05C 19.50 88 87 79 DNG 09H 5.92 25 87 79 DNG 09H 6.33 21 87 121 DNG 08H 37.76 13 88 84 DNG 08C 35.39 27 89 93 DNG A16 14.98 33 90 76 DNG 03H 21.71 105 90 82 DNG 08C 8.26 25 90 82 DNG 08C 8.64 23 92 80 DNT A6
-.34 85 96 50 DNG 08H 34.24 74 96 50 DNG 08H 35.37 74 96 84 DNG A15
-1.41 27 97 67 DNT 05H
-.15 90 99 109 DNT 09C
.57 9
100 54 DNG TSC
.97 82 100 122 DNG A16 17.56 15 105 73 DNG TSC
.60 102 105 107 DNG 07C 7.73 9
106 104 DNG 05C 13.65 3
108 114 DNG 04H 8.54 11 110 80 DNG A6 16.09 3
111 47 DNG TSH 5.30 14 112 82 DNG 08C 33.06 1
115 45 DNG Al 14.52 16 117 57 DNG 08C 37.39 14 117 57 DNG 09C
-1.98 14 118 66 DNG 03H 34.23 24 119 51 DNG 08C 36.32 16 C-3 Appendix C
Dents and Dings SG-D 119 51 DNG 08C 37.45 16 119 51 DNT A9
-.21 16 119 53 DNT 09C
-.58 16 120 86 DNG 02H 8.55 1
124 84 DNG 08C 4.61 3
126 78 DNT Al
.74 1
126 78 DNT Al
.74 5
126 88 DNG A12 19.81 5
126 88 DNG A12 20.53 3
127 87 DNG All 20.72 1
C-4 Appendix C
APPENDIX D TUBES WITH OTHER ANOMALOUS SIGNALS
Tubes with Other Anomalous Signals SG-A ROW COL INDICATION LOCATION CAL NUMBER 1
31 BLG 09C
-1.27 46 1
89 ADS 06H 14.24 43 1
101 ADS 06H 35.56 43 2
30 ADS 02C 36.23 48 2
88 ADS TSH 24.85 43 2
92 ADS 05C 8.54 68 2
94 ADS 05C 17.92 66 2
138 ADS 02H 12.23 45 2
142 ADS 02H 9.29 45 2
142 ADS TSH 9.33 45 3
27 ADS 01C 18.10 32 3
55 ADS TSH 27.76 55 3
129 ADS 01C 7.25 64 3
129 ADS FBC 13.47 64 3
153 BLG 08C 37.35 64 4
18 ADS 02C 10.05 32 4
102 MBM 05C 23.61 64 4
128 ADS 04H 12.78 39 4
59 ADS 04C 14.77 52 5
2 ADS 04C 20.62 20 6
2 ADS 05H 10.37 57 7
9 BLG 09C
-1.17 18 7
19 MBM 02C 27.46 24 7
31 BLG 09C
-1.37 34 7
145 BLG 09C
-1.30 51 8
24 ADS 04H 21.61 28 8
46 ADS 05C 35.17 38 8
54 ADS 0IC 13.59 42 9
79 ADS TSC 33.41 88 10 52 ADS TSH 10.37 44 10 54 ADS 04C 21.10 42 10 58 ADS 03H 3.69 50 10 66 ADS 01C 18.22 56 10 102 MBM 01H 4.28 29 11 11 ADS 01H 5.49 32 11 85 ADS 08H 30.00 27 12 60 ADS 01C 16.93 58 12 72 ADS 01C 2.30 88 12 94 MBM 03H 5.44 23 12 116 ADS TSH 6.57 39 12 118 BLG 08C 37.20 41 12 140 ADS FBC 8.04 53 13 45 ADS 01C 20.67 38 13 53 ADS 01C 14.48 42 13 53 ADS TSC 5.95 42 13 55 ADS 01H 26.27 52 13 105 ADS TSC 14.18 35 14 40 MBM 03C 5.40 40 14 108 ADS TSC 6.59 37 D-1 Appendix D
Tubes with Other Anomalous Signals SG-A 14 116 ADS 01C 6.28 37 14 150 MBM 05H 12.31 51 16 78 ADS 02H 35.34 88 16 86 MBM TSH 23.14 19 16 100 ADS TSC 35.70 29 16 136 ADS 02C 7.83 49 16 136 ADS FBH 4.57 49 18 86 ADS O1H 36.93 19 18 92 ADS 01C 20.64 25 19 23 ADS 02H 35.38 24 19 25 ADS 02H 22.99 22 19 101 ADS 02H 37.07 29 19 141 BLG FBH 17.41 51 20 94 MBM 04C 27.40 23 21 87 ADS TSC 4.11 23 22 54 ADS 01C 14.45 42 22 54 ADS FBC 15.99 42 22 54 ADS FBH 2.84 42 22 54 ADS FBH 15.68 42 22 76 ADS TSC 6.72 60 22 116 ADS 01H 37.67 37 24 54 ADS 01C 3.28 42 24 86 ADS 03H 15.74 19 25 21 MBM 02H 26.78 22 25 131 ADS 05H 8.70 49 26 24 MBM TSC 14.26 28 26 106 BLG 08C 32.77 35 27 43 MBM 04H 30.03 40 27 51 ADS 01H 35.53 44 27 83 ADS 03H 5.57 19 28 122 ADS 01C 3.85 47 29 113 ADS 03H 33.56 35 29 151 ADS 03H 34.69 53 30 54 ADS 03H 14.36 42 30 118 ADS 03C 13.76 39 31 89 MBM 03H 7.71 25 31 125 ADS FBC 15.38 47 31 149 ADS 05C 6.31 51 31 149 ADS 05H 13.03 51 32 52 ADS 03H 11.92 44 32 108 ADS 03H 23.34 37 32 110 ADS 02H 22.94 35 32 110 ADS 08H 28.91 35 32 110 ADS 09H 10.16 35 32 110 ADS TSH 9.77 35 33 75 MBM 01H 37.13 62 33 143 ADS 01C 26.78 53 34 54 ADS 04C 24.01 42 34 122 ADS 03C 13.99 47 35 109 ADS 01C 3.11 35 36 60 ADS 08C 35.28 58 36 60 ADS 08H 33.67 58 D-2 Appendix D
Tubes with Other Anomalous Signals SG-A 36 60 ADS 09H 13.99 58 36 80 ADS 08C 35.13 17 36 80 ADS 08H 33.60 17 36 80 ADS A2 1.03 17 36 80 ADS A2 9.65 17 37 43 ADS 01C 22.27 40 37 43 ADS 07H 1.78 40 38 40 ADS 03C 38.01 40 38 40 ADS 08H 7.78 40 38 74 ADS 03C 5.82 60 38 74 ADS 05C 5.80 60 38 106 ADS FBC 4.10 35 39 39 MBM 06C 37.04 36 39 65 BLG 08H 34.15 56 40 14 ADS FBC 9.14 14 40 50 MBM 05H 29.06 42 40 98 MBM A15 4.59 27 40 100 MBM 04C 18.40 29 40 132 ADS 02C 28.91 49 41 55 ADS 01C 4.75 52 41 137 ADS 02H 35.32 51 42 50 MBM 07H 34.07 42 42 52 ADS 03C 25.76 44 42 54 ADS 03H 26.19 42 42 54 ADS FBC 7.52 42 42 54 ADS TEC 22.20 42 43 83 ADS TSH 7.33 19 45 73 ADS 02H 24.89 60 45 73 ADS 02H 38.24 60 45 139 MBM 08C 4.71 53 46 110 ADS 03H 14.70 35 46 110 ADS 07C 6.32 35 47 19 PVN A14
-.44 24 47 53 ADS 01C 13.68 42 47 105 ADS 03C 534 35 48 42 MBM 06H 26.73 38 48 46 MBM 03H 27.13 38 48 118 ADS FBC 12.88 39 50 132 ADS 09H 47.87 49 51 11 ADS FBH 7.04 20 51 41 ADS 03C 22.90 38 51 41 ADS 05C 20.96 38 53 139 ADS 05H 24.50 53 55 19 PVN A14 6.91 24 56 50 ADS 03H 26.59 42 56 114 ADS 01C 11.66 39 57 49 ADS 01C 20.15 42 57 117 ADS 03H 22.83 39 57 117 ADS 07C 9.00 39 58 42 ADS 01C 8.50 38 58 112 ADS TSC 11.91 37 59 47 ADS 01C 25.30 44 D-3 Appendix D
Tubes with Other Anomalous Signals SG-A 59 47 ADS TSC 6.87 44 59 73 MBM 01C 9.53 60 59 143 ADS 02C 37.83 53 60 142 ADS TSC 1.94 51 60 142 ADS TSC 10.58 51 62 58 MBM 09H 3.63 50 62 118 ADS 01C 9.52 39 64 128 ADS 05C 9.25 15 64 138 ADS 01C 23.97 17 65 39 ADS TSC 7.48 40 65 45 ADS TSC 8.47 38 65 47 ADS TSC 15.62 44 66 90 ADS 01C 15.66 23 66 92 ADS 01C 29.34 25 66 92 MBM TSC 14.44 25 66 126 MBM 03H 8.66 17 66 130 ADS 07H 30.06 17 67 123 ADS 01C 31.40 15 69 105 MBM 06C 14.20 31 69 113 ADS FBC 6.04 35 70 18 ADS 04C 32.70 16 70 18 ADS 06C 9.98 16 70 72 ADS 01C 23.30 62 71 87 ADS A12 10.76 23 71 123 MBM 01H 14.72 15 72 126 ADS 01C 8.49 17 72 126 ADS 01C 17.56 17 72 126 ADS 01C 18.52 17 72 130 ADS FBC 3.95 17 72 130 ADS TSC 2.29 17 73 99 MBM 06H 6.34 27 73 113 ADS 01C 16.91 35 74 102 ADS 01C 15.81 31 74 138 ADS 03H 22.07 17 76 94 MBM 03H 30.72 23 76 94 MBM 03H 35.49 23 76 116 ADS FBC 5.50 41 78 126 ADS TSC 15.19 13 78 128 ADS 01C 9.33 15 78 128 ADS FBC 7.14 15 78 128 ADS TSC 3.72 15 78 128 ADS TSC 14.96 15 79 111 ADS TSC 9.11 37 79 135 ADS 01C 25.02 15 81 29 ADS 01C 34.42 12 81 29 BLG 07C 37.29 12 81 123 ADS TSC 17.76 11 81 127 MBM 02H 34.15 15 81 129 ADS 03H 21.16 17 81 129 ADS 04C 27.67 17 81 131 ADS 04C 19.81 15 82 82 ADS TSH 10.04 19 D-4 Appendix D
Tubes with Other Anomalous Signals SG-A 83 51 ADS 01C 21.46 44 83 51 ADS 02C 20.16 44 83 129 ADS 03H 19.26 13 83 131 ADS 03H 26.68 15 84 24 ADS TSC 2.24 14 84 44 ADS 06C 3.46 40 84 44 ADS 08H 3.72 40 84 114 ADS 03C 13.42 39 85 129 ADS 03H 31.03 13 85 131 ADS 03H 26.22 15 86 28 MBM 08H 20.69 10 86 70 ADS TSC 17.87 60 87 27 ADS 01C 22.20 10 87 27 ADS TSC 2.40 10 89 87 ADS 06C 19.03 19 90 130 ADS 03H 9.64 17 92 106 ADS 03H 24.72 35 93 31 ADS TSC 14.64 10 93 117 ADS 03H 28.11 13 93 129 ADS 03H 28.79 13 94 78 ADS FBC 3.39 15 94 106 ADS 020 23.72 35 94 106 ADS FBC 8.48 35 95 91 ADS TSC 17.10 23 96 48 ADS FBC 2.08 44 96 116 BLG A4 10.58 11 96 116 BLG A4 10.67 13 97 51 ADS 07H 16.27 44 97 99 MBM 03H 6.32 27 97 99 MBM 03H 6.46 27 97 117 ADS 09H 2.72 13 98 36 ADS TSC 4.97 10 98 52 BLG 08C 7.56 44 98 56 ADS 010 23.43 52 98 56 ADS TSC 8.31 52 98 106 ADS 03H 6.82 35 99 69 ADS 05C 31.56 60 100 34 ADS 04H 38.23 12 100 50 ADS 01H 33.70 8
100 50 ADS 02H 17.14 8
101 35 ADS 02C
-.89 10 101 79 MBM 01C 25.01 19 102 50 ADS 01C 29.63 8
102 60 ADS 01H 37.34 52 102 60 ADS 02H 20.25 52 102 106 MBM TSC 12.27 7
103 35 MBM 02C 18.36 10 103 85 MBM TSC 16.17 21 103 121 ADS 01C 28.90 13 103 121 ADS TSC 6.48 13 104 52 ADS 01C 18.38 6
D-5 Appendix D
Tubes with Other Anomalous Signals SG-A 104 78 ADS 07C 4.67 15 104 78 ADS TSC 2.63 15 105 89 ADS 03H 14.55 21 105 107 ADS TEH 23.11 7
106 84 MBM 09H 7.08 55 106 94 ADS 05C 11.27 23 106 110 ADS 03H 12.32 11 108 50 ADS 02H 27.52 8
108 54 MBM 01H 26.76 8
108 70 ADS 02H 23.41 60 108 102 ADS 02C 18.75 7
108 112 ADS TSC 6.83 13 110 48 ADS 01C 19.03 6
110 74 ADS 01C 23.39 60 110 106 ADS FBC 8.79 7
111 97 ADS 05C 25.20 1
113 85 ADS 01C 4.88 1
115 61 ADS 07H 30.20 8
115 79 ADS 02C 33.26 5
116 90 ADS 07C 35.55 5
116 98 ADS 07C 15.18 1
117 67 ADS 06C 21.23 2
117 73 BLG TSC 1.06 4
117 85 ADS A12 33.95 5
118 52 ADS FBC 3.12 6
118 96 ADS 01C 4.94 1
120 52 ADS 04C 15.89 6
121 101 ADS 09H 17.59 9
121 101 ADS FBC 16.19 9
122 64 NQS 01C 3.07 2
126 78 ADS FBC 5.66 3
D-6 Appendix D
Tubes with Other Anomalous Signals SG-B ROW COL INDICATION LOCATION CAL NUMBER 1
43 ADS 02C 1500 86 1
43 ADS 03C 35.63 86 1
43 ADS 05H 23.83 111 1
43 ADS 05H 23.83 125 2
2 ADS 01C 27.54 86 2
2 ADS FBC 11.49 86 3
101 MBM 05H 2.19 99 3
101 MBM 05H 2.24 117 4
88 ADS TSH 23.84 117 4
88 ADS TSH 24.48 99 4
94 BLG 09H
-1.58 119 4
94 BLG 09H
-1.54 101 4
98 ADS TSH 2.61 119 4
98 ADS TSH 2.79 101 4
98 ADS TSH 2.80 99 4
98 BLG 09H
-1.52 99 4
98 BLG 09H
-1.50 119 4
98 BLG 09H
-1.46 101 5
119 ADS TSH 15.21 99 5
119 ADS TSH 15.56 119 5
125 MBM 06C 35.19 71 5
125 MBM 06C 35.20 106 5
127 MBM 02C 36.16 108 5
151 ADS 01H
-1.22 95 6
52 ADS TSH 7.31 36 6
58 MBM TSC 22.22 32 7
3 BLG 09H
-1.27 107 7
3 BLG 09H
-1.25 82 7
83 ADS 07C 17.79 141 8
2 ADS 01H 13.04 74 8
2 ADS FBH 14.23 74 8
46 ADS 01H 24.08 46 8
124 ADS FBH 13.55 71 9
33 ADS 07C 14.16 52 9
47 ADS 01H 18.07 107 9
81 MBM TSC 8.94 141 11 147 ADS TSC 10.95 100 11 153 MBM 01C 12.63 100 12 22 ADS 01H 20.68 58 14 12 ADS 06C 17.92 82 14 12 ADS 08C 13.33 82 15 113 ADS 08C 21.65 63 16 76 ADS 01H 25.68 141 16 88 MBM 01C 17.95 51 17 19 ADS FBH 13.92 58 17 31 ADS 01H 18.21 54 19 73 ADS 05C 13.73 122 19 79 ADS 01H 31.98 141 19 85 ADS 04C 19.35 141 D-I Appendix D
Tubes with Other Anomalous Signals SG-B 20 92 ADS 08C 18.73 53 21 115 MBM TSC 6.55 65 22 54 MBM 06C 9.21 32 22 68 MBM 03C
-1.68 22 22 76 ADS 07H 10.69 122 22 80 MBM TSH 5.51 122 23 31 ADS 01H.
36.71 54 23 43 MBM 06H 9.56 46 23 131 ADS 01C 20.25 103 23 131 ADS FBC 13.84 103 23 131 ADS TSC 7.76 103 23 137 MBM TSH 16.72 83 24 54 MBM 06C 5.58 32 24 56 MBM 04H 19.13 30 24 60 MBM 06C 17.52 30 25 25 ADS 03C 18.00 56 26 4
ADS 03C 14.09 74 26 10 ADS 07C 13.65 70 26 70 MBM 03C 37.36 12 27 91 MBM 05H 15.30 55 28 84 MBM 04C 15.06 15 28 84 MBM 04C 15.07 45 29 121 ADS 02H 12.82 67 30 112 ADS 03C 35.33 65 30 116 MBM 07H 37.27 67 32 48 ADS TSC 17.37 42 32 94 ADS TSH 6.38 55 32 148 ADS 02H 12.34 97 33 7
ADS 01H 16.19 74 33 15 ADS 01H 23.33 62 33 43 ADS 03C 23.62 46 34 136 ADS 03H 37.23 75 36 44 ADS 02C 32.42 44 37 41 ADS TSC 17.79 44 38 62 MBM 01C 33.94 28 38 122 ADS 05C 8.97 69 39 55 ADS 03C 9.56 32 39 119 ADS 08H 6.84 65 39 123 ADS 03C 24.48 69 40 52 ADS 02H 27.66 34 42 58 ADS 03C 27.99 32 43 69 MBM 03C 21.86 18 43 69 MBM 03H 34.81 18 43 69 MBM 05C 32.77 18 44 50 ADS 03C 28.01 36 45 11 ADS 01H 11.60 70 46 56 ADS 01H 28.62 30 46 88 ADS 01C 14.24 49 46 106 MBM 04C 7.96 59 47 83 ADS 06H 17.32 102 47 83 ADS 06H 17.42 101 49 97 ADS FBC 16.91 57 D-2 Appendix D
Tubes with Other Anomalous Signals SG-B 50 132 ADS TSH 10.97 71 51 105 ADS 06H 37.81 59 51 105 ADS 06H 37.81 61 51 139 MBM 05C 17.01 81 52 132 ADS 07C 5.79 71 53 17 ADS 03C 2.43 60 53 17 MBM TSC 10.97 60 53 65 MBM 04C 9.22 22 54 70 BLG 08C 26.90 20 55 23 ADS A12 7.97 58 55 45 MBM 03H 33.36 44 58 48 MBM 03C 22.15 42 58 80 ADS 02H 22.66 13 58 84 MBM 02C 30.39 45 58 84 MBM 02C 30.51 15 60 106 ADS 01C 37.01 59 63 49 ADS 02H 7.81 42 63 57 ADS 01H 4.27 30 63 57 ADS 01H 17.82 30 64 14 ADS 07C 37.61 66 64 70 BLG 06H
-.57 20 65 17 ADS 03C 5.83 64 65 41 MBM 01H 33.25 44 66 96 ADS 01H 37.90 53 68 46 NQS 03C 37.57 40 68 68 MBM 04C 25.97 22 73 53 ADS 09H 29.12 34 73 103 MBM 06H 27.31 29 75 53 ADS 07H 4.05 34 75 59 MBM 03H 28.96 28 75 59 MBM 04H
-1.80 28 75 61 MBM 07H 29.50 26 75 71 BLG 08C 31.43 20 75 107 MBM 04H 30.79 37 76 24 MBM 04C 14.80 68 76 26 MBM 01C 21.80 78 76 56 MBM 02C 29.46 34 76 56 MBM 04H 18.31 34 76 56 MBM 06C 29.12 34 76 74 MBM 05C 35.89 12 76 74 MBM 05C 37.92 12 78 22 ADS TSH 10.49 70 78 54 ADS 07C 18.88 36 81 35 ADS A2 12.81 50 81 91 MBM 06H 10.12 25 81 103 MBM 01H 16.18 29 82 22 ADS 01C 33.67 70 85 55 MBM 05H 22.81 32 85 55 MBM 05H 22.84 32 85 55 MBM 07H 1.49 32 85 55 MBM 07H 1.69 32 85 55 MBM A7
-1.61 32 D-3 Appendix D
Tubes with Other Anomalous Signals SG-B 85 55 MBM TSC 8.51 32 85 55 MBM TSC 9.04 32 86 74 ADS 02C 16.10 80 86 132 ADS 02C 18.51 47 87 33 MBM 01H 29.51 52 88 110 MBM FBH 17.09 37 90 110 ADS 07H 1.77 37 91 115 MBM FBC 9.55 37 92 92 MBM 04C 3.71 23 92 116 ADS TSC 18.21 39 93 57 ADS FBC 7.82 30 93 125 ADS 02C 6.50 43 95 63 MBM A2 16.55 24 95 71 MBM 07H 544 2
96 112 ADS 02C 29.76 39 96 124 MBM 04C 35.31 43 97 123 MBM 05H 5.39 41 97 123 MBM TSC 4.88 41 99 63 MBM 02C 3.07 28 101 117 ADS TSH 3.11 39 102 70 MBM 04C 31.06 20 102 122 MBM TSC 9.06 41 103 91 MBM 08H 6.85 25 104 40 MBM TSC 17.99 48 105 43 MBM FBH 11.55 40 107 49 MBM 04H 16.22 38 108 68 MBM 03H 20.37 22 108 108 MBM 05C 1.52 35 109 57 ADS 07H 17.62 32 110 50 MBM A16 4.84 36 110 82 MBM 06C 22.81 5
110 82 MBM 06C 22.89 7
112 42 ADS 03C 9.45 46 112 74 MBM 05C 28.14 6
114 50 ADS 03C 4.92 36 115 63 MBM TSC 16.91 28 115 73 MBM 04H 37.99 6
119 57 BLG A13
.11 32 120 74 MBM 02H 5.56 6
121 71 ADS 03C 4.63 2
121 71 ADS 03C 5.19 2
121 71 ADS 03C 5.67 2
124 66 ADS FBH 4.29 20 127 71 BLG 09H
-.49 2
D-4 Appendix D
Tubes with Other Anomalous Signals SG-C ROW COL INDICATION LOCATION CAL NUMBER 1
45 BLG 09C
-.44 64 1
57 BLG 09C
-1.60 64 1
63 MBM 06C
-1.86 66 2
118 BLG 09H
-1.86 71 2
43 MBM 02C 24.81 62 4
19 ADS TSH 8.44 19 7
127 ADS FBC 8.95 20 7
54 ADS 02H 11.88 39 8
124 MBM 07H 34.92 66 9
135 ADS 08C 34.40 16 11 83 MBM 02C 19.86 83 12 96 ADS TSC 21.38 48 13 119 BLG A2 6.32 36 13 123 ADS 07C 5.58 58 13 131 BLG A2 3.94 20 13 133 BLG A3
.00 22 14 146 MBM FBH 7.20 14 15 37 MBM 07H 17.33 29 15 117 BLG 07H 8.14 40 16 16 ADS TSC 6.18 13 16 64 MBM 05H 32.00 53 17 17 ADS 02H 30.98 13 17 153 ADS TSC 8.44 10 19 121 ADS TSH 17.56 58 20 40 MBM 01C
-1.99 27 21 63 MBM 01C 31.73 53 24 144 ADS 08C 19.58 10 30 14 ADS 02C 24.80 15 33 85 MBM 08H 12.36 52 35 149 MBM 04C 4.81 14 38 78 ADS 01C 25.73 54 39 83 ADS 01C 14.69 50 39 93 ADS TSH 12.99 48 40 128 ADS FBC 12.51 22 40 140 ADS 06C 28.62 14 41 143 MBM 05C 14.73 12 44 110 MBM 03C 32.40 42 44 110 MBM 03C 34.03 42 44 110 MBM 08C 1.54 42 46 38 ADS 02H 24.95 29 48 42 BLG 09H 3.28 25 49 111 ADS 02H 4.52 38 49 111 ADS 07H 21.75 38 49 111 MBM 01C 13.72 38 49 111 MBM 05C 18.79 38 50 22 ADS I01C 9.69 19 D-1 Appendix D
Tubes with Other Anomalous Signals SG-C 54 144 ADS FBC 10.78 10 55 57 MBM 04H 30.31 39 55 67 MBM 04C 8.91 53 56 142 ADS 02C 17.58 8
57 15 ADS 03H 12.44 15 57 121 ADS 04H 29.40 58 59 97 ADS 07H 16.86 48 60 52 MBM 08C 13.52 41 61 127 MBM 02H 13.61 20 65 25 ADS 05C 37.87 37 67 93 ADS 02C
-1.51 48 67 115 MBM FBC 14.76 38 68 34 ADS 02C 32.39 29 70 116 MBM 03H 21.26 40 71 119 ADS 01C 10.32 36 71 133 ADS FBC 7.16 10 73 123 ADS 01C
-.89 28 73 139 MBM 06C 33.37 8
74 42 ADS 01C 22.19 25 77 91 MBM FBH 8.32 46 77 95 MBM 05H 37.41 46 79 123 ADS 04C 37.38 28 80 24 ADS 03H 11.91 9
82 66 ADS 01C 11.13 51 82 66 ADS 02C 10.62 51 84 70 ADS 01C 9.57 55 84 70 ADS 02C 4.85 55 84 70 ADS FBC 16.45 55 85 95 MBM 08C 37.14 46 86 90 ADS TSH 3.07 50 89 77 ADS TEC 10.90 61 90 66 ADS 01C 14.09 51 90 66 ADS 01C 29.25 51 90 66 ADS FBC 3.00 51 90 66 ADS TSC 17.83 51 90 72 ADS 01C 26.89 61 90 72 ADS FBC 4.17 61 90 98 ADS 09H 38.93 46 96 50 ADS 03H 19.66 58 96 72 ADS 02C 34.89 61 96 104 MBM 06C 20.98 44 97 29 MBM A4 12.37 11 97 99 ADS A4 24.33 46 98 36 MBM 080 29.60 9
101 81 ADS 01C 11.40 56 102 74 ADS 01C 27.32 59 102 86 ADS 07C 7.15 50 107 85 ADS TSC 16.45 52 107 93 ADS FBC 12.49 48 108 50 NQS TSH 1.80 7
111 55 NQS TSH 1.64 7
111 81 ADS 07H 30.83 6
D-2 Appendix D
Tubes with Other Anomalous Signals SG-C 115 51 NQS TSH 1.70 7
116 100 MBM 02H 14.42 4
117 55 NQS TSH 1.87 7
118 72 NQS 03H 5.04 1
119 55 NQS TSH 1.87 7
124 94 MBM 04H 13.47 6
D-3 Appendix D
Tubes with Other Anomalous Signals SG-D ROW COL INDICATION LOCATION CAL NUMBER 1
69 BLG 07C 35.93 106 1
119 BLG 08H 35.24 85 1
119 BLG 08H 35.51 117 1
121 BLG 08H 36.36 115 1
121 BLG 08H 36.59 87 1
137 BLG 09H
-.98 115 3
57 MBM 07C 3515 108 3
57 MBM 07C 35.16 112 3
141 BLG 08H 37.71 85 3
141 BLG 08H 37.76 115 3
149 MBM 04C 14.64 108 5
89 ADS TSH 24.67 87 6
144 BLG 09H
-1.40 83 7
35 MBM 02H 20.88 97 7
35 MBM 02H 20.89 109 7
35 MBM 05H 17.17 97 7
35 MBM 05H 17.26 109 8
10 ADS 04C 13.12 111 8
10 ADS 05C 8.58 111 8
10 ADS 05C 9.92 111 8
28 ADS FBH 17.51 60 8
84 BLG Al 5.29 136 8
84 BLG Al 5.48 83 8
120 NQS 02C 35.95 67 9
69 ADS 02H 33.79 111 9
69 ADS 02H 33.99 94 9
69 ADS TSH 36.17 111 10 50 ADS 02H 18.23 74 10 54 BLG 01H 4.97 93 10 54 BLG 01H 5.19 109 10 62 ADS 04H 26.90 92 10 74 ADS 02C 27.60 136 11 29 ADS 02H 14.87 58 11 29 ADS 02H 30.84 58 11 35 MBM TSC 16.32 62 11 35 MBM TSC 16.36 56 14 124 BLG 08C 39.42 67 14 128 MBM FBH 2.94 71 14 146 ADS 04H 5.30 81 14 146 ADS 07H 13.03 81 15 99 ADS 05H 8.91 43 16 8
ADS 01H 17.08 42 17 33 ADS-07C 18.45 97 17 83 ADS 02C 9.06 83 17 97 ADS 02C 22.55 41 17 101 ADS 02C 22.56 45 17 129 MBM 01C 22.15 69 17 133 ADS 07C 22.74 73 18 30 MBM 04C 29.59 58 18 56 ADS FBH 17.04 80 18 122 BLG A16 6.58 65 D-1 Appendix D
Tubes with Other Anomalous Signals SG-D 19 57 ADS 02C 34.94 80 21 5
MBM 02H 7.09 42 21 29 MBM 02C 2.69 58 22 14 ADS FBH 3.14 34 22 46 ADS 04C 26.08 74 23 69 ADS 01H 7.09 98 23 69 ADS 01H 7.17 100 26 66 ADS 03C 30.84 96 26 66 ADS TSC 16.45 96 28 4
MBM 01H 28.96 44 28 58 ADS 02C 27.98 80 29 11 ADS 01H 11.30 40 29 65 MBM 07C 7.68 92 29 77 ADS 01H 15.22 105 30 32 MBM 01C 16.92 56 30 70 ADS 08C 14.43 100 30 104 MBM 03H 21.30 47 31 41 MBM 04C 35.91 66 32 46 MBM 03C 2.27 74 32 50 MBM 08C 24.30 74 33 21 ADS 06C 4.50 48 33 133 ADS OIH 34.70 85 33 133 ADS 02H 4.12 85 35 55 ADS 06C 18.08 76 37 41 MBM 07H 33.12 66 37 59 MBM 05C 12.87 80 37 145 MBM 02C 25.54 81 40 34 ADS 03C 12.39 62 43 79 MBM 06C 26.66 25 43 121 ADS 01H 37.21 65 43 121 ADS 02H 5.77 65 45 43 MBM 04C 4.99 68 45 59 ADS 07H 6.76 80 46 50 ADS FBH 3.79 74 47 37 ADS 01H 33.19 62 47 49 ADS 08C 28.53 74 47 59 ADS 06C 28.82 80 47 97 ADS 02H 19.56 41 47 97 ADS 07H 4.45 41 48 142 MBM 02C 24.73 77 48 144 MBM 08C 13.09 79 49 37 ADS O1H 34.50 62 49 37 ADS 05H 3.40 62 49 37 ADS 07H 1.70 62 49 37 ADS 08H 13.28 62 49 127 ADS TSC 17.56 71 50 84 MBM TSC 10.54 27 50 108 MBM 03H 38.91 51 50 118 ADS 08C 25.93 65 54 114 ADS 07H 22.00 57 54 118 ADS 02C 21.88 65 55 79 ADS 03C 15.87 25 D-2 Appendix D
Tubes with Other Anomalous Signals SG-D 57 89 ADS 06C 36.40 31 58 116 MBM 03C 1.86 59 59 43 ADS A16 10.64 68 59 65 BLG 08H 1.85 92 60 86 ADS 01C 32.61 29 61 103 ADS 05H 38.04 47 63 107 ADS 08H 20.43 51 64 54 ADS 02C 31.76 82 65 63 ADS FBC 15.84 86 65 63 ADS TSC 13.20 86 65 139 MBM 08C 33.37 15 66 42 ADS 03C 8.70 70 66 66 MBM 07C 14.02 96 66 66 MBM 07C 25.84 96 67 39 BLG 03C 16.28 60 67 123 MBM 08C 13.00 67 67 129 MBM 07C 5.84 69 68 126 MBM 07C 4.60 69 73 49 MBM 01H 31.69 74 73 133 ADS 03H 13.55 13 74 134 MBM 04C 19.53 15 75 63 ADS 02C 7.41 86 75 63 ADS 05C 3.36 86 75 63 ADS 07H 32.17 86 75 67 MBM 01C 20.25 90 77 27 ADS 01H 13.64 6
77 27 ADS 01H 24.24 6
78 74 MBM 04H 15.84 98 79 19 ADS 03C 10.32 6
79 51 ADS 03C 12.35 72 79 53 MBM 05H 2.26 78 79 95 ADS TSH 12.77 35 79 97 ADS 01H 37.22 41 79 137 ADS 07H 9.98 15 80 46 ADS 01C 35.56 70 80 46 ADS 09H 42.22 70 83 61 ADS 01H 28.93 88 83 89 ADS TSH 8.16 31 85 33 ADS 02C 8.61 30 85 39 ADS A10 5.98 60 85 103 MBM 05C 8.79 47 86 54 MBM 05H 29.77 82 88 122 MBM 06H 11.21 15 93 129 ADS 01H 35.93 13 93 129 ADS 01H 36.50 15 94 102 ADS All 3.19 49 97 103 MBM 03C 35.99 47 98 52 MBM A12 13.01 72 98 110 MBM 02H 29.12 9
98 122 ADS FBH 2.52 15 99 121 ADS 01H 36.41 13 99 121 MBM 03H 17.68 13 D-3 Appendix D
Tubes with Other Anomalous Signals SG-D 102 86 MBM 07H 30.95 29 103 35 MBM 04H 10.38 30 103 121 ADS FBH 15.18 13 103 121 ADS TSH 4.08 13 104 100 NQS 02C 9.97 47 105 67 MBM 04H 11.55 90 108 42 MBM TSC 8.93 14 112 86 MBM 02C
-1.83 1
114 92 MBM 05C 10.01 31 117 95 ADS 01H 27.74 1
120 82 ADS 03H 35.47 1
122 78 ADS 04H 23.34 1
D-4 Appendix D
APPENDIX E TUBES REMOVED FROM SERVICE PRIOR TO INSTALLATION
w&vE cooiw mazisd~ rgrA l~4 -o;l AuwQ3 -ýw v%4w61-m 9
01 91 00400*0 0.*
.[
0c Sz BE se OP
£t 09 95 09 S9 0L SL 08 S8 06 S6 Gel 9O1 OIT 911 Q;i GZT OCT gel OI SVI 01T S99 00 000 0
000,0 000 000000 000,00
'0 0000 000 000 00000a 0,'
0000 C,0.0000 0
000 0
0 C,
0
- 0.
0
.....°°.°u.oo.°
°
.~o
.°°
.o o
.~
0 9
0T 91 8z Sz Be Sc 0S 99 09 99 09 98 06 S6 Be 01 901 SIT 911 9Z1 S
al S1 az Sz BC SE av SP 09 S9 09 S9 OL SL 08 98 06 96 O01 SOT 011 SIT
@ZT SZT OCT SET OVI SVT' OST S91 dM AUoiDui :ZoOIo I V I
0
- o.
.'°
- o.
.°
.o
.o o
.i.
°
.°
.*.°.
° P
o
.o.
.°.
.°
- °..
.o
- o...
- 0.
~..
o
- 0.
0 SZ1 V6G XHS ISd sexes qlnoS I
AJOPSIH eqn_ peS6 nlnd V - OS
- o*
- o
- Q
- ° *
- S 0Q
- 9 09 ST Sz ot 88 98 901 091 991 061
10tO L
MC t JZW 00Z.LS ()SN' 0-1 A~edýO, DIN WN&MOtM OT 9T OZ SZ 9E St O'
917 09 99 09 99 gL 9L 08 99 06 96 o0T 90!
OT S9$
OZT SZT OCT 9SET OVT SIT$
091 SST 00 0
0C 0 00of0 00 0
,0
ý,"0 00 0
000lI"o.'0 000o0 0
00 0"0 0,
0 oý 0 0 0
0 0 00l-0
'o 0
0000 00 00 00 0,0,0",00 0000~~ 000 000 0000 0
000 0
0 0
000 0 0 00 0
000 0
0 0
0 0
0 0
0 0
0 0
0 o0 0 0.
i.%
.°*
.o%
.°~
- ~
.o S
9~~.
'- O T
..S S-I.- I.
I ST T...:.- T. :..
.i:
0
.7.
0 o0 o..
.o
.{-
.=
.'." "..S o~~~
T T-.
as
.9 66.....
..9.;*
S_0.
eL~~
~~
~
9*~~
0
.0..
.9
.i. '?.i......
o6 i...-.....,,,:
0.0.
0 0 0 0 0
.0.
es, 1
.g
..°
.s 9 o0 s1 92 92 0*
9*
o, 9,
99 99 99 99 9L 9L 99 99 06 96 9o1 99!
911 91!
921 921 911 911 ot',
91' 991o 991 dM AJoioej :*OO/IIO Z V 1P6( XHI ISd sexes flnos Aiols!H eqnL p 566nlcl 8 - O5 3
3
)
SG - C PNugged Tube History C
A 3 01/2002: Factory WP 155 150 145 140 0
0 0
o
- 0.
- 0.
0.*
0.*
0 o0 o
o0.
125 120 115 110 185 100 95 90 85 80 75 70 0.
35 130 125 128 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 38 25 20 15 1@
5 01 0 000 000a
{ý 0.
120
.0....
.110
- 0.
00 0.o 0
- 0.
0.
-0 0'
- 0.
0.
+
4.~~~~
.1.
.4*..
,.0o
- 0 ro t ;
+.-.-
-.----.- F -A--
- .0
.....1.:.
- 7I77YY~77777.§7I.17.
.:V7:.::B.:t.;
.UIjf.LL.LIL.
0 0
0 0
- .0
.~~~~~~
105 100 95 90
-85 80 75 70 65 60 55 50 45 40 35 0
30 20 15 0:....
...
% o.,o. Q Oo.
o,*o,. Oo,o o
-oo
- O, o o
...o~
.~o
.~
oo
~
o o 545 121 1
05 100 95 90 85 80 75 7
65 6
0 55 1 4 0
0000 00 0000 0
155 150 145 140 135 138 125 120 115 11e 10Be 5
90 8
0 7
0 5
6 5
5 45 4@
35 30 26 20 15 10 5
5 Webgho-Elctm CoP-y LLC NSDU ST2=OO 02/2712D)2 13 41 22 0
0 60 55 50 45 40 35 30 Z5 20 15 10 Sg 0°
- I I * -.
- 4.
-.1. -
.v 07 S.
r-T "l"
¢ S.
6 Q *
- I g
k h
T t ---------
1-
.4 L
S@
I t.
0 t)
SG - D Plugged Tube History - No Tubes Plugged South Texas PSI THX D94 155 150 145 140 135 1. I
- -I I
.30 125 120 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5
S.
.f,-
.?I.1...
,l
-.. 0
+ -
4---
4-
.0*
.o
.o..
°
.*o i~
o
.°
.1...
.t~.o
.t 0
o~~~~~
~~.'
.oo...o
- °.
0,*
oo
°**
° i
-a n-~~~~~
.~
00 o.....-.............*...-............
- ~~~..............,....
i...........
iiti.¢itiitit.....
t.*.l..:
i..I.....*
0 0
0...
- 0.
0....
S 0
0 0*. ~
~
~
~
~
~
~ ~..
- .*j.
t..l***.]..*.
i...
.**]
0 o0
...'T.K
=
0 125 1z2 115 110 195 10 95 90 as 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5
125 120 115 110 105 180 95 90 85 80 75 70 65 60 55 56 45 48 35
_ ~.
2 5
°
°
°
.... I..
- ..1:....
- -t"
!' *°..
- " " t" "i.
..° " " " " " " " "
- 2.-
29 1
.i
...T 15 5
0000 0000 0
0 0
000 0000 9
900 0
0 0000 0000 00050 900 0 000 0
0 0000 0
155 159 145 149 135 138 125 12e 115 119 105 109 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 29 15 10 5
Wesb, gho..
El-wedc Company LLC - NS3U M'l" 02=272002 13 50 04 o0 m
o..,..° i : i iio
.......: : : : l : : °:°.
......°~,
APPENDIX F OWNER'S REPORT FOR INSERVICE INSPECTIONS NIS-1 FORM
FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules
- 1. Owner South Texas Proiect Nuclear Oneratinu Comnanv*: P 0 Box 289: Wadsworth Texas 77483 (Name and Address of Owner)
- 2. Plant South Texas Proiect Electric Generating Station: P.O. Box 289: Wadsworth, Texas 77483 (Name and Address of Plant)
- 3. Plant Unit 2
- 4. Owner and Certificate of Authorization (if required)
N.A
- 5. Commercial Service Date 6/19/89
- 6. National Board Number for Unit N.A.
- 7. Components Inspected ASME Code Class 1 (IVB) Items - Steam Generator Tubes Component or Manufacturer Manufacturer State or National Appurtenance or Installer or Installer Province No.
Board No.
Serial No.
Steam Generator Westinghouse Electric THXE-NA.
78 lR122NSG201A Company, LLC (M) 40342/IFM2 Steam Generator Westinghouse Electric TH)E-N.A.
79 1R122NSG201B Company, LLC (M) 40343/2FM2 Steam Generator Westinghouse Electric THXE-N.A.
80 1R122NSG201C Company, LLC (M) 40344/3FM2 Steam Generator Westinghouse Electric THXE-N.A.
81 1Rl22NSG201D Company, LLC (M) 40345/4FM2
- South Texas Project Nuclear Perating Company (STPNOC) is the licensed operator of the Sf u'exas Project Electric Generating Station K -
STPNOC by j
atel-ký Factory Mutual by Date --,. 7- 06 nL.I-anng Insurance Co.
B.R.RussellANII Page 1
FORM NIS-I (Back)
- 8.
Examination Dates 1-10-2002 to 12-6-2002
- 9.
Inspection Period Identification: First Period (10/19/00 to 10/18/03)
- 10.
Inspection Interval Identification: Second Interval (10/19/00 to 10/18/10)
- 11.
Applicable Edition of Section XI 1989 Addenda None
- 12. Date / Revision of Inspection Plan:
September 2000/Revision 0
- 13.
Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. (AMSE Code Class 1 (IWB) Items - Steam Generator Tubes)
See Section 4.0 of the "Preservice Inspection Summary Report for Tubing in the Replacement Steam Generators of the South Texas Project Electric Generating Station Unit 2"
- 14.
Abstract of Results of Examinations and Tests. (AMSE Code Class 1 (IWB) Items - Steam Generator Tubes)
See Section 5.0 of the "Preservice Inspection Summary Report for Tubing in the Replacement Steam Generators of the South Texas Project Electric Generating Station Unit 2"
- 15.
Abstract of Corrective Measures. (AMSE Code Class 1 (IWB) Items - Steam Generator Tubes)
See Section 5.0 of the "Preservice Inspection Summary Report for Tubing in the Replacement Steam Generators of the South Texas Project Electric Generating Station Unit 2" We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.
Certificate of Authorization No. (if applicable)
N.A.
Expiration Date N-A Date Z
20,63 Signed STP Nuclear Operating Comapn, By Owner
/J)L Ha Page 2 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Texas and employed by Factory Mutual Insurance Co.
of__
Johnston, RI have inspected the components described in this Owner's Report during the period 1-10-2002 to 12-6-2002
, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connecte t this inspection.
Commtssions Te 826 Inspector's Signature National Board, State, Province, and Endorsements B R. Russell Date cý -
- 20.
.