ML030650980

From kanterella
Jump to navigation Jump to search

Tech Spec Change No. 02-03, Rev 2, License Amendment Request to Support Unit 1 Steam Generator Replacement Project
ML030650980
Person / Time
Site: Sequoyah  Tennessee Valley Authority icon.png
Issue date: 02/26/2003
From: Salas P
Tennessee Valley Authority
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
TAC MB5370 TVA-SQN-TS-02-03, R2
Download: ML030650980 (5)


Text

Tennessee Valley Authonty, Post Office Box 2000, Soddy-Daisy, Tennessee 37379-2000 February 26, 2003 TVA-SQN-TS-02-03, R2 10 CFR 50.90 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555 Gentlemen:

In the Matter of " - Docket No. 50-328 Tennessee*Valley AUthoity: )

SEQUOYAHTINUCLEAR*PLANT ý-"-UNIT1_2 - TECHNICAL SPECIFICATION (TS) CHANGE NO. 02-03, REVISION 2, LICENSE AMENDMENT REQUEST (LAR) TO SUPPORT 'UNIT '1 S'TEAM-'GENERATOR' REPLACEMENT PROJECT (TAC No. MB5370) -

References:

1. TVA letter to NRC dated November 15, 2002, "Sequoyah Nuclear Plant (SQN) - Unit 2 Technical Specification (TS) Change No. 02-03, Revision 1, License Amendment Request (LAR) to Support-Unit 1 Generator Replacement Project" TAC No. MB5370 .
2. TVA letter to NRC dated January 15, 2003, "Sequoyah Nuclear Plant (SQN) - Steam Generator Replacement Project - Topical Report No. 24370-Tr-C-002, "Rigging And Heavy Load
  • .. :Handling Topical Report, ".Response To NRC "Request For -Additional' Irif6rmaition'" ""

Iniacco-d'danoewthCtHe prlbViii6ns o'f-*10:CFR 50:.90">TTVA":j2s requesting an amendment to Unit 2 Operating License (OL)

DPR-79. The proposed request adds a one-time condition for conduct-o6fheavy loadf'ifts associated with the Sequoyah Unit.'l steam g~nierator replacement project. -The -one-itiriie Prrtedonrecycled paper

U.S. Nuclear Regulatory Commission Page 2 February 26, 2003 condition establishes special provisions and requirements for safe operation of Unit 2 while heavy load lifts are performed on Unit 1. The provision for heavy load lifts is described in Topical Report 24370-TR-C-002. The topical report, as supplemented by Reference 2, contains prerequisite actions for heavy load movement, active monitoring during heavy load movement, and compensatory measures in response to the unlikely event of a heavy load drop.

The enclosed revised one-time license condition replaces the license condition proposed in TVA TS Change 02-03, Revision 1, provided by Reference 1. As discussed with the NRC staff, this revision is needed to direct the application of the license condition to a table (3.1) that is to be created in the NRC safety evaluation. This table is intended to be a list of those actions TVA will take prior to performing the subject heavy load lifts as well as those actions to be taken for a postulated drop of the heavy load.

TVA has determined that there are no impacts to the significant hazards considerations provided by Revision 1 of this change request. Additionally, in accordance with 10 CFR 50.91(b) (1), TVA is sending a copy of this letter and enclosure to the Tennessee State Department of Public Health.

The enclosure contains a page from Unit 2 OL marked-up to show the proposed change. TVA requests NRC review and approval to support the Sequoyah Unit 1 steam generator replacement outage currently scheduled to begin March 16, 2003.

U.S. Nuclear Regulatory Commission Page 3 February 26, 2003 There are no additional commitments contained in this submittal. This letter is being sent in accordance with NRC RIS 2001-05. If you have any questions about this change, please telephone me at (423) 843-7170 or J. D. Smith at (423) 843-6672.

Sincerely, Pedro Salas Licensing and Industry Affairs Manager I declare under penalty of perju that the foregoing is true and correct. Executed on this day of tr.24k1.

Enclosure:

Marked-up pages from the Sequoyah Unit 2 License cc: (Enclosure)

Mr. Raj K. Anand, Senior Project Manager U.S. Nuclear Regulatory Commission Mail Stop O-8G9 One White Flint North 11555 Rockville Pike Rockville, Maryland 20852-2739 Mr. Lawrence E. Nanney, Director Division of Radiological Health.

Third Floor L&C Annex 401 Church Street Nashville, Tennessee 37243-1532 Framatome ANP, Inc.

3315 Old Forest Road P. 0. Box 10935 Lynchburg, VA 24506-0935 ATTN: Mr. Frank Masseth

ENCLOSURE TENNESSEE VALLEY AUTHORITY SEQUOYAH PLANT (SQN)

UNIT 2 PROPOSED LICENSE AMENDMENT MARKED PAGES I. AFFECTED PAGE LIST Unit 2 Operating License Page 11 II. MARKED PAGES See attached.

E-1

INSERT A (19) Steam Generator Replacement Project During the Unit 1 Cycle 12 refueling and steam generator replacement outage, lifts of heavy loads will be performed in accordance with Table 3.1 of NRC SER dated E-3