Suppression Chamber-to-Drywell Vacuum Breakers 3.6.1.7 SURVEILLANCE REQUIREMENTS

-- NNOTES

1. Not required to be met for vacuum breakers that are open during Surveillances.
2. Not required to be met for vacuum breakers open when performing their intended function.

Verify each vacuum breaker is closed.

NOTE -

Not required to be met for vacuum breaker 21SC*RV36B for the remainder of Cycle 9.

Perform a functional test of each vacuum breaker.

FREQUENCY i

14 days 31 days AND Within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after any discharge of steam to the suppression chamber from the safety/relief valves SR 3.6.1.7.3 Verify the opening setpoint of each 24 months vacuum breaker is *0.25 psid.

Amendment -4, 98, 108 SURVEILLANCE SR 3.6.1.7.1 SR 3.6.1.7.2 NMP2 3.6.1.7-3