Public Meeting Between USNRC Davis-Besse Oversight Panel and FirstEnergy Nuclear Operating Company December 10, 2002
2 Davis-Besse Oversight Panel - Public Meeting December 2002 Purposes of This Meeting
- Inform the Public of the NRCs Oversight Panel Activities
- Discuss Licensees Progress on Implementing the Return to Service Plan
3 Davis-Besse Oversight Panel - Public Meeting December 2002 AGENDA
- Introduction and Opening Remarks
- Summary of November 13th Public Meetings
- Discussion of NRCs Restart Checklist and Status of NRC Inspections
- Licensee Presentation on the Status of Their Return to Service Plan
- Adjourn NRC meeting with FENOC
<break>
- Public Comments and Questions of NRC
- Adjourn Meeting
4 Davis-Besse Oversight Panel - Public Meeting December 2002
SUMMARY
OF NOV. 13, 2002 PUBLIC MEETING Topics Discussed
- Quality Assessment Value-Added
- Reactor Vessel Bottom Head Plan
- System Health Assurance
- Design Issues Resolution
- Management and Human Performance Actions
- Operations Leadership Plan
- Transcripts of the Nov. 13, 2002, meetings will be available on our web site. http://www.nrc.gov/
5 Davis-Besse Oversight Panel - Public Meeting December 2002 Restart Checklist Adequacy of Root Cause Determination
- Penetration cracking and reactor pressure vessel corrosion
- Organizational, programmatic and human performance issues
6 Davis-Besse Oversight Panel - Public Meeting December 2002 Restart Checklist
- Adequacy of Safety Significant Structures, Systems, and Components
- Reactor pressure vessel head replacement
- Containment vessel restoration
- Structures, systems and components inside containment
- Emergency core cooling system and containment spray system sump
- Systems outside containment
7 Davis-Besse Oversight Panel - Public Meeting December 2002 Restart Checklist
- Adequacy of Safety Significant Programs
- Corrective action
- Operating experience
- Quality audits and self-assessments
- Boric acid corrosion management
- Reactor coolant system unidentified leakage monitoring
- In-service inspection
- Modification control
- Radiation protection
8 Davis-Besse Oversight Panel - Public Meeting December 2002 Restart Checklist
- Adequacy of Organizational Effectiveness and Human Performance
- Adequacy of root causes
- Adequacy of corrective actions
- Effectiveness of corrective actions
9 Davis-Besse Oversight Panel - Public Meeting December 2002 Restart Checklist
- Readiness for Restart
- Systems readiness for restart
- Operations readiness for restart
- Test program development and implementation
10 Davis-Besse Oversight Panel - Public Meeting December 2002 Restart Checklist
- Licensing Issue and Confirmatory Action Letter Resolution
- Resolve three limited ASME code relief requests
- Meet with the NRC to obtain restart approval
11 Davis-Besse Oversight Panel - Public Meeting December 2002 CONTINUING NRC INSPECTIONS Organizational Effectiveness and Human Performance Safety Significant Program Effectiveness Resident Inspection