Technical Specifications Pages for Amendmentds 144 & 132 End of Life (Eol) Moderator Temperature Coefficient (Mtc) Surveillance Requirements
ML023400524
Person / Time
Site: South Texas  
(NPF-076, NPF-080)
Issue date: 11/26/2002
From:
NRC/NRR/DLPM/LPD4
To:
Thadani M, NRR/DLPM, 415-1476
Shared Package
ML023400262 List:
References
TAC MB5160, TAC MB5161
Download: ML023400524 (1)


Text

REACTIVITY CONTROL SYSTEMS SURVEILLANCE REQUIREMENTS 4.1.1.3 The MTC shall be determined to be within its limits during each fuel cycle as follows:

a. The MTC shall be measured and compared to the BOL limit specified in the COLR prior to initial operation above 5% of RATED THERMAL POWER, after each fuel loading; and
b.

The MTC shall be measured at any THERMAL POWER and compared to the 300 ppm surveillance limit specified in the COLR (all rods withdrawn, RATED THERMAL POWER condition) within 7 EFPD after reaching an equilibrium boron concentration of 300 ppm.* In the event this comparison indicates the MTC is more negative than the 300 ppm surveillance limit specified in the COLR, the MTC shall be remeasured, and compared to the EOL MTC limit specified in the COLR, at least once per 14 EFPD during the remainder of the fuel cycle.

Measurement of the MTC in accordance with Surveillance Requirement 4.1.1.3.b may be suspended, provided that the benchmark criteria in WCAP-1 3749-P-A (refer to 6.9.1.6.b.10) and the Revised Prediction specified in the COLR are satisfied.

SOUTH TEXAS - UNITS 1 & 2 3/4 1-7 Unit 1 - Amendment No. 27,' 144 Unit 2 - Amendment No. T7; 132 I