Part 11 of 17, CD-ROM Providing the Review Tool Supporting the Application for Renewal of Operating License
ML023170590
Person / Time
Site: Robinson 
Issue date: 11/06/2002
From: Fletcher B
Carolina Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RNP-RA/02-0164
Download: ML023170590 (7)


Text

TABLE 3.3-2 TABLE 2 AUXILIARY SYSTEMS Component Commodity Group Constituents:

Component/Commodity Group System No 2060 Chemical And Volume Control System Charging Pump LubeTank(s)

1. Pumps, Valves, Tanks, Piping and Fittings (Primary Sampling, CVCS, Spent Fuel Pool Cooling), Spent Fuel Racks, CVCS Heat Exchangers, Pulsation Dampers, Flow Orifices/ Elements, Seal Injection Filter, Seal Return Filter, Volume Control Tank, Valves,etc Charging Pump Suction Stabilizers and Pulsation Dampeners Charging Pump(s)

Excess Letdown Heat Exchanger Tubing Flow Orifices/Elements Regenerative Heat Exchanger Tubing, Shell, and Cover Seal Injection Filter Seal Return Filter Seal Wtr Heat Exchanger Tubing Valves, Piping, Tubing and Fittings Volume Control Tank System No 2115 Primary Sampling System (PS)

Valves, Piping and Fittings

1. Pumps, Valves, Tanks, Piping and Fittings (Primary Sampling, CVCS, Spent Fuel Pool Cooling), Spent Fuel Racks, CVCS Heat Exchangers, Pulsation Dampers, Flow Orifices/ Elements, Seal Injection Filter, Seal Return Filter, Volume Control Tank, Valves,etc System No 7110 Spent Fuel Pool Cooling System (SFPCS)

Flow Orifices/Elements

1. Pumps, Valves, Tanks, Piping and Fittings (Primary Sampling, CVCS, Spent Fuel Pool Cooling), Spent Fuel Racks, CVCS Heat Exchangers, Pulsation Dampers, Flow Orifices/ Elements, Seal Injection Filter, Seal Return Filter, Volume Control Tank, Valves,etc Valves, Piping and Fittings Wednesday, October 23, 2002 Page 1 of 7 NRC: Table 3-x-2 Table 2 w/ Union Query

TABLE 3.3-2 TABLE 2 AUXILIARY SYSTEMS Component Commodity Group Constituents:

Component/Commodity Group System No 8300S46 Bldgs 215, 220 and 225: Fuel Handling Building Spent Fuel Storage Rack

1. Pumps, Valves, Tanks, Piping and Fittings (Primary Sampling, CVCS, Spent Fuel Pool Cooling), Spent Fuel Racks, CVCS Heat Exchangers, Pulsation Dampers, Flow Orifices/ Elements, Seal Injection Filter, Seal Return Filter, Volume Control Tank, Valves,etc Component Commodity Group Constituents:

Component/Commodity Group System No 2060 Chemical And Volume Control System Charging Pump LubeTank(s)

2. Charging Pump Lube Tanks, CVCS and Sampling System Piping, Valves, Tubing, and Fittings, Flow Elements and Filters Flow Orifices/Elements Seal Injection Filter Seal Return Filter Valves, Piping and Fittings Valves, Piping, Tubing and Fittings System No 2115 Primary Sampling System (PS)

Valves, Piping and Fittings

2. Charging Pump Lube Tanks, CVCS and Sampling System Piping, Valves, Tubing, and Fittings, Flow Elements and Filters Component Commodity Group Constituents:

Component/Commodity Group System No 2060 Chemical And Volume Control System Excess Letdown Heat Exchanger Tubing

3. CVCS Excess Letdown, Seal Water, and Class 2 portion of Regenerative Heat Exchanger Regenerative Heat Exchanger Tubing, Shell, and Cover Seal Wtr Heat Exchanger Tubing Component Commodity Group Constituents:

Component/Commodity Group System No 6185 Emergency Diesel Generator Car Dox System (CARDOX)

Wednesday, October 23, 2002 Page 2 of 7 NRC: Table 3-x-2 Table 2 w/ Union Query

TABLE 3.3-2 TABLE 2 AUXILIARY SYSTEMS Component Commodity Group Constituents:

Component/Commodity Group Piping and Fittings

4. Flexible Hoses and Couplings (CO2, Halon, CARDOX)

System No 6195 Fire Protection CO2 System (CO2)

Piping and Fittings

4. Flexible Hoses and Couplings (CO2, Halon, CARDOX)

System No 6205 Halon Supply System (HALON)

Piping and Fittings

4. Flexible Hoses and Couplings (CO2, Halon, CARDOX)

Component Commodity Group Constituents:

Component/Commodity Group System No 5095 Diesel Generator System (DIESEL)

Piping and Fittings

5. Flexible Hoses and Couplings (DG System, DS Diesel, EOF DG, Instrument Air, and Fuel Oil Systems)

System No 5098 Dedicated Shutdown Diesel Generator (DSD)

Piping and Fittings

5. Flexible Hoses and Couplings (DG System, DS Diesel, EOF DG, Instrument Air, and Fuel Oil Systems)

Valves, Piping, Tubing and Fittings System No 5100 Fuel Oil System (FO)

Piping and Fittings

5. Flexible Hoses and Couplings (DG System, DS Diesel, EOF DG, Instrument Air, and Fuel Oil Systems)

System No 6082 EOF/TSC Security Emergency Diesel Gen. (EOF DG)

Piping and Fittings

5. Flexible Hoses and Couplings (DG System, DS Diesel, EOF DG, Instrument Air, and Fuel Oil Systems)

System No 6135 Instrument Air System (IA)

Valves, Piping and Fittings

5. Flexible Hoses and Couplings (DG System, DS Diesel, EOF DG, Instrument Air, and Fuel Oil Systems)

Component Commodity Group Constituents:

Component/Commodity Group System No 6270 Primary And Demineralized Water Makeup System (DW)

Wednesday, October 23, 2002 Page 3 of 7 NRC: Table 3-x-2 Table 2 w/ Union Query

TABLE 3.3-2 TABLE 2 AUXILIARY SYSTEMS Component Commodity Group Constituents:

Component/Commodity Group Valves, Piping and Fittings

6. Primary and Demineralized Water Valves, Piping, and Fittings Component Commodity Group Constituents:

Component/Commodity Group System No 6270 Primary And Demineralized Water Makeup System (DW)

Valves, Piping and Fittings

7. Primary and Demineralized Water Valves, Piping, and Fittings Component Commodity Group Constituents:

Component/Commodity Group System No 2060 Chemical And Volume Control System Valves, Piping, Tubing and Fittings

9. Valves, Piping, Tubing, and Fittings Component Commodity Group Constituents:

Component/Commodity Group System No 5098 Dedicated Shutdown Diesel Generator (DSD)

DSD Air Volume Tank

10. DS Diesel Air Volume Tank, Piping, Valves, Tubing, and Fittings Valves, Piping, Tubing and Fittings Component Commodity Group Constituents:

Component/Commodity Group System No 4060 Service Water System (SW)

Piping and Fittings

11. Service Water and Fire Water Piping and Fittings System No 6175 Site Fire Protection System (SFPS)

Piping and Fittings

11. Service Water and Fire Water Piping and Fittings Component Commodity Group Constituents:

Component/Commodity Group System No 5098 Dedicated Shutdown Diesel Generator (DSD)

Valves, Piping, Tubing and Fittings

12. Ventilation Equipment Frames and Housings and Heating/ Cooling Coils; Fuel Oil and Diesel Generator Valves, Piping Tubing and Fittings System No 5100 Fuel Oil System (FO)

Valves, Piping, Tubing and Fittings

12. Ventilation Equipment Frames and Housings and Heating/ Cooling Coils; Fuel Oil and Diesel Generator Valves, Piping Tubing and Fittings System No 8150 HVAC Containment Building System (HVAC)

Wednesday, October 23, 2002 Page 4 of 7 NRC: Table 3-x-2 Table 2 w/ Union Query

TABLE 3.3-2 TABLE 2 AUXILIARY SYSTEMS Component Commodity Group Constituents:

Component/Commodity Group Equipment Frames and Housings

12. Ventilation Equipment Frames and Housings and Heating/ Cooling Coils; Fuel Oil and Diesel Generator Valves, Piping Tubing and Fittings Heating/Cooling Coils System No 8220 HVAC Control Room Area (HVAC)

Equipment Frames and Housings

12. Ventilation Equipment Frames and Housings and Heating/ Cooling Coils; Fuel Oil and Diesel Generator Valves, Piping Tubing and Fittings Component Commodity Group Constituents:

Component/Commodity Group System No 5098 Dedicated Shutdown Diesel Generator (DSD)

Valves, Piping, Tubing and Fittings

13. Valves, Piping, Tubing and Fittings System No 5100 Fuel Oil System (FO)

Valves, Piping, Tubing and Fittings

13. Valves, Piping, Tubing and Fittings Component Commodity Group Constituents:

Component/Commodity Group System No 4060 Service Water System (SW)

Piping and Fittings

14. Valves, Piping, and Fittings System No 6135 Instrument Air System (IA)

Valves

14. Valves, Piping, and Fittings System No 6175 Site Fire Protection System (SFPS)

Piping and Fittings

14. Valves, Piping, and Fittings Component Commodity Group Constituents:

Component/Commodity Group System No 2060 Chemical And Volume Control System Excess Letdown Heat Exchanger Shell and Cover

15. Components in or Serviced by a Closed-Cycle Cooling Water System Seal Wtr Heat Exchanger Shell and Cover System No 5095 Diesel Generator System (DIESEL)

D/G After Coolant Heat Exchangers Shell

15. Components in or Serviced by a Closed-Cycle Cooling Water System D/G Jacket Water Heat Exchangers Shell System No 5098 Dedicated Shutdown Diesel Generator (DSD)

Wednesday, October 23, 2002 Page 5 of 7 NRC: Table 3-x-2 Table 2 w/ Union Query

TABLE 3.3-2 TABLE 2 AUXILIARY SYSTEMS Component Commodity Group Constituents:

Component/Commodity Group DSD Expansion Tank

15. Components in or Serviced by a Closed-Cycle Cooling Water System DSD Immersion Heater DSD Lube Oil Cooler Shell DSD Radiator Tubing DSD Radiator Waterbox System No 6082 EOF/TSC Security Emergency Diesel Gen. (EOF DG)

EOF DG Radiator

15. Components in or Serviced by a Closed-Cycle Cooling Water System Component Commodity Group Constituents:

Component/Commodity Group System No 2060 Chemical And Volume Control System Charging Pump Heat Exchanger Tubing

16. Components in or Serviced by a Closed-Cycle Cooling Water System System No 4080 Component/Closed Cooling Water System CCW Heat Exchanger tubing
16. Components in or Serviced by a Closed-Cycle Cooling Water System Rod Drive Cooling System Cooler Tubing Waste Gas Compressor Cooler Tubing System No 5095 Diesel Generator System (DIESEL)

D/G After Coolant Heat Exchangers Tube Sheet

16. Components in or Serviced by a Closed-Cycle Cooling Water System D/G After Coolant Heat Exchangers Tubing D/G Jacket Water Heat Exchangers Tube Sheet D/G Jacket Water Heat Exchangers Tubing Valves, Piping, Tubing and Fittings System No 5098 Dedicated Shutdown Diesel Generator (DSD)

DSD Lube Oil Cooler Tubing and Fins

16. Components in or Serviced by a Closed-Cycle Cooling Water System System No 6082 EOF/TSC Security Emergency Diesel Gen. (EOF DG)

Valves, Piping, Tubing and Fittings

16. Components in or Serviced by a Closed-Cycle Cooling Water System Component Commodity Group Constituents:

Component/Commodity Group Wednesday, October 23, 2002 Page 6 of 7 NRC: Table 3-x-2 Table 2 w/ Union Query

TABLE 3.3-2 TABLE 2 AUXILIARY SYSTEMS Component Commodity Group Constituents:

Component/Commodity Group System No 4080 Component/Closed Cooling Water System CCW Heat Exchanger Tube Sheet

17. Heat Exchangers Tubes and Tubesheet Serviced by the Open-Cycle Cooling Water System CCW Heat Exchanger tubing System No 8210 HVAC Auxiliary Building (HVAC)

Heating/Cooling Coils

17. Heat Exchangers Tubes and Tubesheet Serviced by the Open-Cycle Cooling Water System Component Commodity Group Constituents:

Component/Commodity Group System No 4015 Circulating Water System Piping and Fittings

18. Valves, Piping and Fittings System No 6175 Site Fire Protection System (SFPS)

Piping and Fittings

18. Valves, Piping and Fittings Component Commodity Group Constituents:

Component/Commodity Group System No 4080 Component/Closed Cooling Water System Rod Drive Cooling System Cooler Tubing

25. Rod Drive Cooling System Cooler Tubing Component Commodity Group Constituents:

Component/Commodity Group System No 4060 Service Water System (SW)

Piping and Fittings

29. Valves, Piping, and Fittings in Service Water System and Site Fire Protection System System No 6175 Site Fire Protection System (SFPS)

Valves, Piping and Fittings

29. Valves, Piping, and Fittings in Service Water System and Site Fire Protection System Component Commodity Group Constituents:

Component/Commodity Group System No 6175 Site Fire Protection System (SFPS)

Diesel Driven Fire Pump

30. Diesel-and Motor-Driven Fire Pump Casing Motor Driven Fire Pump Wednesday, October 23, 2002 Page 7 of 7 NRC: Table 3-x-2 Table 2 w/ Union Query