November 8, 2002 Mr. John L. Skolds, President Exelon Nuclear Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555

SUBJECT:

RELIEF REQUEST FOR ALTERNATIVE TESTING OF CONTAINMENT SUMP SUCTION VALVES 1/2SI8811A/B FOR BYRON STATION, UNITS 1 AND 2, AND BRAIDWOOD STATION, UNITS 1 AND 2 (TAC NOS. MB6638, MB6639, MB6636 AND MB6637)

Dear Mr. Skolds:

Exelon Generation Company, LLC (Exelon) is requesting Nuclear Regulatory Commission (NRC) approval of a proposed alternative to the requirements of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code,Section XI, Rules for Inservice Inspection of Nuclear Power Plant Components, ASME/ANSI Oma-1988, Operations and Maintenance of Nuclear Power Plants, 1987 Edition through the 1988 Addenda, Part 10, Section 4.2.1.1 for the Braidwood and Byron Stations. The NRC staff received the relief request on October 31, 2002, and Exelon requested a completion date by March 1, 2003. This provides us a review period of only 4 months.

The NRC performance goals for licensing actions is to complete 95 percent in less than one year and 100 percent is less than two years. The NRC staff finds your proposed target date for completion of our review to be aggressive, but the NRC staff will endeavor to complete its review consistent with the proposed schedule.

The NRC faces significant challenges in balancing its workload, available resources, and budget constraints to achieve its performance goals. Accordingly, it is important that you plan your submittals to enable the NRC staff to perform its review in an efficient manner consistent with our performance goals and your schedule.

Please contact me at (301) 415-8371 if you have any questions on this issue.

Sincerely,

/RA/

Mahesh Chawla, Project Manager, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos.

STN 50-454, STN 50-455, STN 50-456, and STN 50-457 cc: See next page

November 8, 2002 Mr. John L. Skolds, President Exelon Nuclear Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555

SUBJECT:

RELIEF REQUEST FOR ALTERNATIVE TESTING OF CONTAINMENT SUMP SUCTION VALVES 1/2SI8811A/B FOR BYRON STATION, UNITS 1 AND 2, AND BRAIDWOOD STATION, UNITS 1 AND 2 (TAC NOS. MB6638, MB6639, MB6636 AND MB6637)

Dear Mr. Skolds:

Exelon Generation Company, LLC (Exelon) is requesting Nuclear Regulatory Commission (NRC) approval of a proposed alternative to the requirements of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code,Section XI, Rules for Inservice Inspection of Nuclear Power Plant Components, ASME/ANSI Oma-1988, Operations and Maintenance of Nuclear Power Plants, 1987 Edition through the 1988 Addenda, Part 10, Section 4.2.1.1 for the Braidwood and Byron Stations. The NRC staff received the relief request on October 31, 2002, and Exelon requested a completion date by March 1, 2003. This provides us a review period of only 4 months.

The NRC performance goals for licensing actions is to complete 95 percent in less than one year and 100 percent is less than two years. The NRC staff finds your proposed target date for completion of our review to be aggressive, but the NRC staff will endeavor to complete its review consistent with the proposed schedule.

The NRC faces significant challenges in balancing its workload, available resources, and budget constraints to achieve its performance goals. Accordingly, it is important that you plan your submittals to enable the NRC staff to perform its review in an efficient manner consistent with our performance goals and your schedule.

Please contact me at (301) 415-8371 if you have any questions on this issue.

Sincerely,

/RA/

Mahesh Chawla, Project Manager, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. STN 50-454, STN 50-455, STN 50-456, and STN 50-457 cc: See next page DISTRIBUTION:

PUBLIC MChawla OGC ACRS GHill (4)

PD3-2 r/f AMendiola CRosenberg AStone, RIII HNieh ADAMS Accession Number: ML023050067 OFFICE PDIII-2/PM PDIII-2/LA PDIII-2/SC NAME MChawla CRosenberg LRaghavan for AMendiola DATE 11/4/02 11/4/02 11/4/02 OFFICIAL RECORD COPY

Byron/Braidwood Stations cc:

Ms. C. Sue Hauser, Project Manager Westinghouse Electric Corporation Energy Systems Business Unit Post Office Box 355 Pittsburgh, PA 15230 Joseph Gallo Gallo & Ross 1025 Connecticut Ave., NW, Suite 1014 Washington, DC 20036 Howard A. Learner Environmental Law and Policy Center of the Midwest 35 East Wacker Dr., Suite 1300 Chicago, IL 60601-2110 U.S. Nuclear Regulatory Commission Byron Resident Inspectors Office 4448 N. German Church Road Byron, IL 61010-9750 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, IL 60532-4351 Ms. Lorraine Creek RR 1, Box 182 Manteno, IL 60950 Chairman, Ogle County Board Post Office Box 357 Oregon, IL 61061 Mrs. Phillip B. Johnson 1907 Stratford Lane Rockford, IL 61107 George L. Edgar Morgan, Lewis and Bockius 1800 M Street, NW Washington, DC 20036-5869 Attorney General 500 S. Second Street Springfield, IL 62701 Illinois Department of Nuclear Safety Office of Nuclear Facility Safety 1035 Outer Park Drive Springfield, IL 62704 Byron Station Manager Exelon Generation Company, LLC 4450 N. German Church Road Byron, IL 61010-9794 Site Vice President - Byron Exelon Generation Company, LLC 4450 N. German Church Road Byron, IL 61010-9794 U.S. Nuclear Regulatory Commission Braidwood Resident Inspectors Office 35100 S. Rt. 53, Suite 79 Braceville, IL 60407 Illinois Emergency Management Agency Division of Disaster Assistance &

Preparedness 110 East Adams Street Springfield, IL 62701-1109 Chairman Will County Board of Supervisors Will County Board Courthouse Joliet, IL 60434 Braidwood Station Manager Exelon Generation Company, LLC 35100 S. Rt. 53, Suite 84 Braceville, IL 60407-9619

Byron/Braidwood Stations Ms. Bridget Little Rorem Appleseed Coordinator 117 N. Linden Street Essex, IL 60935 Document Control Desk-Licensing Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Exelon Generation Company, LLC Site Vice President - Braidwood 35100 S. Rt. 53, Suite 84 Braceville, IL 60407-9619 Senior Vice President, Nuclear Services Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President Mid-West Operations Support Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Senior Vice President Mid-West Regional Operating Group Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Director Licensing Mid-West Regional Operating Group Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Exelon Generation Company, LLC Regulatory Assurance Supervisor -

Braidwood 35100 S. Rt. 53, Suite 84 Braceville, IL 60407-9619 Exelon Generation Company, LLC Regulatory Assurance Supervisor - Byron 4450 N. German Church Road Byron, IL 61010-9794 Senior Counsel, Nuclear Mid-West Regional Operating Group Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President - Licensing and Regulatory Affairs Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Manager Licensing - Braidwood and Byron Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555