ML022690186

From kanterella
Jump to navigation Jump to search
Update to Annual Radiological Effluent Report (Arer) January Through December 2001
ML022690186
Person / Time
Site: Browns Ferry  Tennessee Valley Authority icon.png
Issue date: 09/17/2002
From: Abney T
Tennessee Valley Authority
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML022690186 (169)


Text

Tennessee Valley Authority, Post Office Box 2000, Decatur, Alabama 35609-2000 September 17, 2002 U.

S. Nuclear Regulatory Commission ATTN:

Document Control Desk Mail Stop OWFN, Pl-35 Washington, D.C.

20555-0001 Gentlemen:

In the Matter of

)

Docket Nos.

50-259 Tennessee Valley Authority

)

50-260 50-296 BROWNS FERRY NUCLEAR PLANT (BFN)

UNITS 1, 2, AND 3 -

UPDATE TO THE ANNUAL RADIOLOGICAL EFFLUENT REPORT (ARER)

JANUARY THROUGH DECEMBER 2001 This letter provides an updated 2001 ARER including a corrected Enclosure 3, page 12, the original ARER was sent to NRC on April 16, 2001.

This updated ARER also covers the period from January through December 2001, and supersedes the previous ARER.

During a follow-up review of the 2001 ARER, it was identified that Np-239 was erroneously listed as a particulate of the gaseous ground release in the Effluent and Waste Disposal Annual Report portion (Enclosure 3 on Page 12).

As such, this particulate has now been removed from the report.

This erroneous inclusion of Np-239 as a particulate did not have any significant effect on the total curies released from BFN in 2001.

There are no commitments contained in this letter.

If you have any questions, please contact me at (256) 729-2636.

S.)Encerely' E.

Abney Manager Site Licensing and I dustry Af airs Pmted on recycded paWe

U.S. Nuclear Regulatory Commission Page 2 September 17, 2002 Enclosure cc (Enclosure):

(Via NRC Electronic Distribution)

Mr. Kahtan N.

Jabbour, Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint, North (MS 08G9) 11555 Rockville Pike Rockville, Maryland 20852-2738 Mr. Paul E.

Fredrickson, Branch Chief U.S. Nuclear Regulatory Commission Region II 61 Forsyth Street, S.W.,

Suite 23T85 Atlanta, Georgia 30303-8931 NRC Resident Inspector Browns Ferry Nuclear Plant P.O. Box 149 Athens, Alabama 35611 Mr. Ronald Sanacore (w/Enclosure)

American Nuclear Insurers Town Center, Suite 300S 29 South Main Street West Hartford, Connecticut 06107-2430

ENCLOSURE TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT UNITS 1, 2,

AND 3 ANNUAL RADIOLOGICAL EFFLUENT REPORT (ARER)

JANUARY THROUGH DECEMBER 2001 ENCLOSURE 3, PAGE 12 UPDATE (See Attached) 4

ENCLOSURE I TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT (BFN)

UNITS 1, 2, AND 3 RADIOLOGICAL IMPACT ASSESSMENT REPORT 2001 TABLE OF CONTENTS I.

Introduction El -2

[I.

Dose Limits El-2 III.

Dose Calculations El-3 IV Doses from Airborne Effluents El-3 V.

Doses from Liquid Effluents El-5 V1.

Population Doses E1-5 VII.

Offsite Direct Radiation Dose E1-6 VIII.

Dose to a Member of the Public Inside the Site Boundary E 1-6 LX.

Total Dose EI-7

TABLE OF CONTENTS (Continued)

Listing of Tables Table 1 - Doses from Airborne Effluents - First Quarter EI-8 Table 2 - Doses from Airborne Effluents - Second Quarter EI-9 Table 3 - Doses from Airborne Effluents - Tlurd Quarter El-10 Table 4 - Doses from Airborne Effluents - Fourth Quarter El-I I Table 5 - Doses from Liquid Effluents - First Quarter EI-12 Table 6 - Doses from Liquid Effluents - Second Quarter EI-13 Table 7 - Doses from Liquid Effluents - Third Quarter El-14 Table 8 - Doses from Liquid Effluents - Fourth Quarter El-15 Table 9 - Total Dose from Fuel Cycle El-16 Table 10 - Joint Frequency DistribuUon in Percent for Ground E2-2 Level Releases - First Quarter E2-9 Table 11 -Joint Frequency Distribution in Percent for Ground E2-10 Level Releases - Second Quarter E2-17 Table 12 - Joint Frequency Distnbution in Percent for Ground E2-18 Level Releases -Third Quarter E2-25 Table 13 - Joint Frequency Distribution in Percent for Ground E2-26 Level Releases - Fourth Quarter E2-33 Table 14 - Joint Frequency Distribution in Percent for Split Level E2-34 Releases (Ground Level Portion) - First Quarter E2-41 Table 15 - Joint Frequency Distnbuuon in Percent for Split Level E2-42 Releases (Ground Level Portion) - Second Quarter E249 Table 16 - Joint Frequency Distribution in Percent for Split Level E2-50 Releases (Ground Level Portion) - Third Quarter E2-57 Table 1 - Joint Frequency Distribution in Percent for Split Level E2-58

-; Releases (Ground Level Portion) - Fourth Quarter E2-65 Table 18 - Joint Frequency Distribution in Percent for Split Level E2-66 Releases (Elevated Level Portion) - First Quarter E2-73 El-la

TABLE OF CONTENTS (Continued)

Listing of Tables Table 19 - Joint Frequency Distribution in Percent for Split Level E2-74 Releases (Elevated Level Portion) - Second Quarter E2-81 Table 20 - Joint Frequency Distribution in Percent for Split Level E2-82 Releases (Elevated Level Portion) - Third Quarter E2-89 Table 21 - Joint Frequency Distribution in Percent for Split Level E2-90 Releases (Elevated Level Portion) - Fourth Quarter E2-97 Table 22 - Joint Frequency Distribution in Percent for Elevated E2-98 Releases - First Quarter E2-105 Table 23 - Joint Frequency Distribution in Percent for Elevated E2-106 Releases - Second Quarter E2-113 Table 24 - Joint Frequency Distribution in Percent for Elevated E2-114 Releases - Third Quarter E2-121 Table 25 - Joint Frequency Distribution in Percent for Elevated E2-122 Releases - Fourth Quarter E2-129 El-lb

Rad;nogical Impact Assessment r rowns Ferry Nuclear Plant January - December 2001 I. INTRODUCTION Potential doses to the "maximum exposed individual" and the population around Browns Ferry are calculated for each quarter as required in Section 5 2 of the Offsite Dose Calculation Manual (ODCM). The methodolog for determining plant releases for the reporting penod used to estimate dose is specified in Sections 6 and 7 of the ODCM Dispersion of radioactive effluents in the environment is estimated using meteorological data and river flow measured during the period. In this report, the doses resulting from releases are described and compared to lihmts established for Browns Ferry.

II. DOSE LIMITS The ODCM specifies limits for the release of radioacuve effluents, as well as limits for doses to the general public from the release of radioactive effluents These limits are set well below the Technical Specification limits which govern the concentrations of radioactivity and doses permissible in unrestricted areas. This ensures that radioactive effluent releases are As Low As Reasonably Achievable.

The air dose lirmts in areas at and beyond the Site Boundary due to noble gases released in gaseous effluents per unit are:

<5 mrad per quarter and

< 10 mrad per year for gamma radiation.

- and

< 10 mrad per quarter and

< 20 mrad per year for beta radiation.

The dose limits to a Member of the Public in an unrestricted area from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half-lives > 8 days released in gaseous effluents for each unit are:

< 7.5 mrem per quarter and

< 15 mrem per year to any organ.

The dose or dose commitment to a Member of the Public from radioactive material in liquid effluents released to unrestricted areas are:

< 1.5 mrem per quarter and

< 3 mrem per year to the total body,

- and

< 5 mrem per quarter and

< 10 mrem per year to any organ.

The limit for the total effective dose equivalent to an individual Member of the Public inside the site boundary is.¢ 4 100 mrem per year.

The EPA limits for total dose to any Member of the Public in the vicinity of a nuclear power plant, established in the Environmental Dose Standard of 40 CFR 190, are:

< 25 mrem per year to the whole body,

< 75 mrem per year to the thyroid,

- and

< 25 mrem per year to any other organ.

El-2

Radiologic-t lmr

` -kssessment Browns 'c.rry :,uclear Plant January - December 2001 I11. DOSE CALCULATIONS Estimated doses to Members of the Public are determined using computer models (the Gaseous Effluent Licensing Code. GELC, and the Quarterly Water Dose Assessment Code, QWATA) These models are based on guidance provided by the NRC (in Regulatory Guides 1 109, 1.111 and 1 113) for deternuning the potential dose to indi*iduals and populations living in the vicinity of the plant. The area around the plant is analyzed to determine the pathways through which the public may receive a dose. The doses calculated are a representation of the dose to a "maximum exposed individual." Some of the factors used in these calculations (such as ingestion rates) are maximum values to ensure conservative reporting data. Many of these factors are obtained from NUREG/CR-1004 The values chosen will tend to overestimate the dose The expected dose to actual individuals is lower. The calculated doses are presented in Tables 1, 2, 3, 4, 5.

6, 7, 8, and 9.

IV. DOSES FROM AIRBORNE EFFLUENTS For airborne effluents, Members of the Public can be exposed to radiation from several sources-direct radiation from the radioactivity in the air, direct radiation from radioactivity deposited on the ground, inhalation of airborne radioactivity, ingestion of vegetation which contains radioactivity deposited from the atmosphere, and ingestion of milk and beef which contains radioactivity deposited from the atmosphere onto

-vegetation and subsequently consumed by milk and beef animals.

Airborne Release Points There are four monitored release points from Browns Ferry Nuclear Plant: the turbine building, the radwaste building, the reactor building, and the stack.

Releases from the turbine building are considered ground-level releases. The ground-level Joint Frequency Distribution (JFD) is derived from windspeeds and directions measured 10 meters above ground and from the, ertical temperature difference between 10 and 45 meters, and are presented for each quarter in Tables 10, 11. 12, and 13.

Releases from the radwaste and reactor buildings are considered split-level releases. Portions of the release are treated as ground-level while other portions are considered elevated depending on the ratio of the ertical exit velocity to the horizontal wind speed. The split-level dispersion approach is implemented using a model that requires two complete quarterly JFDs for each effluent vent, one for the ground-level releases and one for the elevated releases. The ground-level portion of the split-level JFD is based on wind speeds and directions measured 10 meters above ground-level and from the vertical temperature difference between 10 and 45 meters. The elevated portion of the split-level JFD is based on wind speeds and direction measurements at the 45 meter level and the vertical temperature difference between 45 and 91 meters Both of these JFDs are given for each quarter in Tables 14, 15, 16, 17, 18, 19, 20. and 2 1.

Releases from the stack are considered to be elevated releases. The JFDs for elevated releases are based on

'ýimd directions and wind speeds measured at 91 meters and the vertical temperature difference between 45 and 91 metek, and are given for each quarter in Tables 22, 23, 24, and 25.

El -3

Radiological Impact Assessment Browns Ferry Nuclea ?':

January - December 2001 Meteorological Data Meteorological variables at BFN are measured continuously. Measurements collected include wind speed, wvind directon, and temperature at heights of 10, 45, and 91 meters aboNe the ground. Quarterly.FDs are calculated for each release point using the appropriate levels of meteorological data. A quarterly LFD gives the percentage of the time that the wind is blowing out of a particular upwind compass sector in a particular range of wind speeds for a given stability class A through G. The wind speeds are divided into nine %ýind speed ranges Calms are distributed by direction in proportion to the distribution of noncalm wind directions less than 1.6 m/s (3.5 mph) Stability classes are determined from the vertical temperature difference between two measurement levels The generally open terrain around BFN does not cause any significant effects on the transport and dispersion of gaseous effluents from the plant. Within 30 kilometers of BFN, the terrain is mostly gently rolling hills (30-60 meters) Between 30 and 80 kilometers the hills become larger to the north and south.

and mountainous to the east and northeast. The Tennessee River/Wheeler Lake may have a minor effect on transport and dispersion in the immediate vicinity of BFN during periods of winds with a southerly component, overcast skies, and relatively high wind speeds. Also, the lower layer (10-45 meters) stability class tends to be more stable. However, during this infrequent condition, dose estimates will be conservative.

External Exposure Dose Dose calculated for maximum external air dose (gamma-air and beta-air ) are made for points at and beyond the unrestricted area boundary as described in the BFN ODCM. The highest of these doses is then selected.

Submersion Dose External doses to the skin and total body, due to submersion in a cloud of noble gases, are calculated for the nearest residence in each sector. The residence with the highest dose is then selected from all sectors.

Orzan Dose Dose to an organ due to releases of airborne effluents are estimated for the inhalation, ground contamination, and ingestion pathways. The ingestion pathway is further divided into three possible contributing pathways: ingestion of cow/goat milk, ingestion of beef, and ingestion of vegetables. Doses from applicable pathways are calculated for each receptor location identified in the most recent land use survey. To determine the maximum organ dose, the doses from the pathways are summed for each receptor For the ingestion dose, however, only those pathways that exist for each receptor are considered in the sum.

i e.. milk ingestion doses are included only for locations where milk was consumed without commercial preparation and vegetable ingestion is included only for those locations where a garden was identified. To conservatively account for beef ingestion, a beef ingestion dose equal to that for the highest unrestricted area boundary location is added to each identified receptor. For ground contanunation, the dose added to the organ dose being calculated is the total body dose calculated for that location, i.e., it is assumed that the dose to an individual organ is equal to the total body dose.

The maximum organ dose, thyroid dose, and total body dose from airborne effluents are presented in Tables 1, 2, 3, and 4.

E1-4

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2001 V. DOSES FROM LIQUID EFFLUENTS For liquid effluents, the public can be exposed to radiation from three sources-the ingestion of ater from the Tennessee River, the ingestion of fish caught in the Tennessee River, and direct exposure from radioactme material deposited on the river shoreline sediment (recreauon).

The concentration of radionuclides in the Tennessee River are calculated by a computer model which uses measured hydraulic data downstream of BFN Parameters used to determine the doses are based on guidance given by the NRC (in Regulatory Guides 1.109) for maximum ingestion rates, exposure times. etc Wherever possible, parameters used in the dose calculation are site specific. The models that are used to estimate doses, as well as the parameters input to the models, are described in detail in the BFN ODCM Liquid Release Points and River Data Radionuclide concentrations in the Tennessee River are calculated assuming that releases in liquid effluents are continuous. When necessary, liquid releases from BFN, located at Tennessee River Mile 294, are made through diffusers which extend into the Tennessee River. It is assumed that releases to the river through these diffusers will initially be entrained in one-fifth of the water which flows past the plant. The QWATA code makes the assumption that this mixing condition holds true until the water is completely mixed at the first downstream dam (Wheeler Dam), at Tennessee River Mile 283 0 Doses are calculated for locations within a 50 mile radius downstream of the plant site. The maximum potential recreation dose is calculated for a location immediately downstream from the plant's release point.

The maximum exposed individual dose from ingestion of fish is assumed to be that calculated for the consumption of fish caught anywhere between the plant and the first downstream dam. The maximum exposed individual dose from dnnking water is assumed to be that calculated at the nearest downstream public water supply [West Morgan - East Lawrence (WMEL)I. This could be interpreted as indicating that the maximum e.xposed individual, as assumed for liquid releases from Browns Ferry, is an individual who obtains all of his dnnking water at WMEL, consumes fish caught from the Tennessee River between BFN and Wheeler Dam, and spends 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> per year on the shoreline just downstream of the plant's release point. Doses calculated for the maximum exposed individual due to liquid effluents for each quarter in the period are presented in Tables 5, 6, 7, and 8, along with the average river flows past the plant site for the periods.

VI POPULATION DOSES Population doses due to airborne effluents are calculated for an estimated 627.000 persons living within a 50-mile radius of the plant site. Doses from external pathways and inhalation are based on the 50-mile human population distnbution. Ingestion population doses are calculated assuming that each individual consumed milk, vegetables, and meat produced within the sector in which the individual resides.

Population doses due to liquid effluents are calculated for the entire downstream Tennessee River population. Water ingestion population doses are calculated using actual population figures for downstream public waterisupplies. Fish ingestion population doses are calculated assuming that all sport fish caught in the Tennessee River are consumed by the Tennessee River population. Recreation population doses are calculated using historical recreational data on the number of shoreline visits at downstream locations:

Population doses calculated for airborne and liquid effluents are presented in Tables 1, 2, 3, 4, 5, 6, 7, and 8 El-5

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2001 VII. OFFSITE DIRECT RADIATION DOSE External gamma radiation levels were measured by thermolurmnescent dosimeters (TLDs) deployed around BFN as part of the offsite Radiological Environmental Monitoring Program (REMP) The quarterly gamma radiation levels deterrmned from these TLDs during this reporting period averaged approximately 15 5 mrem/quarter at onsite (at or near the site boundary) stations and approximately 13 25 mrem/quarter at offsite stations or approximately 2 3 mrem/quarter higher onsite than at offsite stations. This difference is consistent with levels measured for pre-operation and construction phases of TVA nuclear plants where the average radiation levels onsite were generally 2-6 mrem/quarter higher than the levels offsite. This may be attributable to natural variations in environmental radiation levels, earth moving activities onsite, the mass of concrete employed in the construction of the plants, or other undetermined influences. Fluctuations in natural background dose rates and in TLD readings tend to mask any small increments which may be due to plant operations. Thus, there was no identifiable increase in dose rate levels attributable to direct radiation from plant equipment and/or gaseous effluents.

VIII. DOSE TO A MEMBER OF THE PUBLIC INSI]DE THE SITE BOUNDARY Pursuant to ODCM section 7.7.5, a review was performed to determine the highest dose to a member of the public in the site boundary. This review assumed that onsite TVA employees engaged in work activities not associated with nuclear power electric generation were considered as members of the public. The dose to a member of the public consists of the sum of dose commitments from effluent releases as well as any direct radiation dose.

The dose from effluent releases consists of inhalation, ingestion, and submersion doses. The inhalation dose commitment assumes that site occupancy factors are sufficiently low to compensate for the increase in the atmospheric dispersion above that for the site boundary. The ingestion dose commitments use the pathways and calculated values described previously for beef, milk, and garden vegetable ingestion as nell as the dose commitments from liquid effluents The submersion dose is an external radiation dose commitment from gaseous effluents.

The direct radiation dose was determined from area TLDs located onsite. It consisted of gamma dose from the plume, ground contamination and from equipment sources (i e., tanks, turbine shine, radioactive material storage areas, etc.). The highest direct radiation dose accounting for background and occupancy was 7.3 mrem dunng 2001.

The total annual dose is the sum of the direct radiation dose (7 3 mrem) and the effluent dose commitment (2.5E-02 torem) or 7.3 mrem. It can be concluded that the dose lirmt for a member of the public inside the site boundary as specified in 10 CFR 20 1301 was not exceeded.

'4 El-6

'diological Impact Assessment Browns Ferry Nuclear Plant January - December 2001 LX. TOTAL DOSE To determine compliance wvith 40 CFR 190, annual total dose contributions to the maximum exposed indi*idual from BFN radioactive effluents and all other nearby uranium fuel cycle sources are considered.

The annual dose to any organ other than thyroid for the maximum exposed individual is conservatively calculated by summing the following doses-the total body air submersion dose for each quarter, the critical organ dose (for any organ other than the thyroid) from airborne effluents for each quarter from ground contamination, inhalation and ingestion, the total body dose from liquid effluents for each quarter, the maximum organ dose (for any organ other than the thyroid) from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the REMP. This dose is compared to the 40 CFR 190 limit for total body or any organ dose (other than thyroid) to determine compliance.

The annual thyroid dose to the maximum exposed individual is conservatively estimated by sumnnung the follovwng doses: the total body air submersion dose for each quarter, the thyroid dose from airborne effluents for each quarter, the total body dose from liquid effluents for each quarter, the thyroid dose from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the REMP This dose is compared to the 40 CFR 190 lihmt for thyroid dose to determine compliance.

Total dose from the fuel cycle is presented in Table 9.

94 El -7

Radiol

-al ' pact Assessment Bro...

Nuclear Plant January - December 2001 Table 1 Doses from Airborne Effluents First Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 6 OE-04 mrad 5 mrad

< I%

S/8000 meters Beta Air 1.8E-04 mrad 10 mrad

< 1%

S/8000 meters Submersion Total Body 5 IE-03 mrem NA NA ESE/1860 meters Skin 6 OE-03 mrem NA NA ESE/1860 meters Organ Doses Child/Bone 1.3E-02 mrem 7.5 mrem

<I %

NNW/1770 meters Child/Thyroid 3.2E-02 n-rem 7 5 mrem

< I%

NNW/1770 meters Child/Total Body 8 2E-03 mrem 7 5 mrem

< I%

NNW/1770 meters Population Doses Total Body Dose 5.5E-02 man-rem Maximum Organ Dose (organ) l.3E-01 man-rem (thyroid)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mremiyr for natural background).

-4 El-8

Individual Doses Radiological Impa4"

  • es.znt Browns Ferry NULlear Plant January - December 2001 Table 2 Doses from Airborne Effluents Second Quarter Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 8.8E-04 mrad 5 mrad

< I%

NW/7500 meters Beta Air 2.7E-04 mrad 10 mrad

< I%

NW/7500 meters Submersion Total Body 3 IE-03 mrem NA NA N/2000 meters Skn 3 6E-03 mrem NA NA N/2000 meters Organ Doses Cluld/Bone 9.OE-03 mrem 7.5 mrem

< 1%

N/2000 meters Child/Thyroid 3.4E-02 mrem 7 5 mrem

< I%

N/2000 meters Child fTotal Body 6.OE-03 mrem 7 5 mrem

< I%

N/2000 meters Population Doses Total Body Dose 3 OE-02 man-rem Maximum Organ Dose (organ) 1 OE-O I man-rem (thyroid)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-remryear (based on 90 mrem/yr for natural background)

El-9

Indiiidual Doses Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2001 Table 3 Doses from Airborne Effluents Third Quarter Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 2 3E-05 mrad 5 mrad

< I%

NW/7100 meters Beta Air 3 7E-05 mrad 10 mrad

< 1%

NW/7 100 meters Submersion Total Body 1.6E-04 mrem NA NA NNW/1639 meters Skin 2.OE-04 mrem NA NA NNW/1639 meters Organ Doses Chuld/Bone 6 2E-03 mrem 7 5 mrem

< 1%

NNW/1770 meters Child/Thvroid 2.7E-02 mrem 7 5 mrem

<I %

NNW/1770 meters Child/Total Body 2.8E-03 mrem 7 5 murem

<I %

NNW/1770 meters Population Doses Total Body Dose 1 IE-02 man-rem Maximum Organ Dose (organ)

8. IE-02 man-rem (thyroid)

Population doses can be compared to the natural background dosefor the entire 50-mile population of about 70,044 man-renmvear (based on 90 mrem/yr for natural background).

El-10

Individual Doses Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2001 Table 4 Doses from Airborne Effluents Fourth Quarter Population Doses Total Body Dose 1.3E-02 man-rem Maximum Organ Dose (organ) 7.3E-02 man-rem (thyroid)

Population, doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-remn/year (based on 90 mrem/yr for natural background).

4 EI-Il Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 4 8E-06 mrad 5 mrad

<1 %

NW/7000 meters Beta Air 7 8E-06 mrad 10 mrad

<1 %

NW/7000 meters Submersion Total Body 2 OE-04 mrem NA NA NNW/1639 meters Skin 2.3E-04 mrem NA NA NNW/1639 meters Organ Doses Child/ Bone I OE-02 mrem 7.5 mrem

<I %

NNW/1770 meters ChildUrhyroid 3 2E-02 mrem 7 5 mrem

<1 %

NNWl1770 meters Child /Total Body 4 9E-03 mrem 7 5 mrem

<1 %

NNW/1770 meters

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2001 Table 5 Doses from Liquid Effluents First Quarter*

Individual Doses (mrem)

Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Total Body Fish Ingesuon 0

Recreation 0

Water Ingestion 0

Total 0

1.5 mrem 0%

Liver Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

5 mrem 0%

Thyroid Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

5 mrem 0%

  • No liquid releases were made this quarter.

A~erage Riverflow past BFN (cubic feet per second): 49241 Population Doses Total Body Dose 0 man-rem Maxamum Organ Dose (organ) 0 man-rem (organ)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

EI-12

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2001 Table 6 Doses from Liquid Effluents Second Quarter*

Indihidual Doses (mrem)

Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Total Body Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

15 mrem 0%

Liver Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

5 mrem 0%

Thyroid Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

5 mrem 0%

  • No liquid releases were made this quarter.

AMerage Riverflow past BFN (cubic feet per second): 19157 Population Doses Total Body Dose 0 man-rem Maximum Organ Dose (organ) 0 man-rem (organ)

Population doses can be compared to the natural background dosefor the entire 50-mile population of about 70.044 man-remn/year (based on 90 mrem/yr for natural background).

EI-13

P'*diolc. 3cal [mpact Assessment

.3rowns Ferry Nuclear Plant January - December 2001 Table 7 Doses from Liquid Effluents Third Quarter Individual Doses (mrem)

Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Total Body Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

15 mrem 0%

Liver Fish Ingestion 0

Recreauon 0

Water Ingestion 0

Total 0

5 mrem 0%

Thyroid Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

5 mrem 0%

  • No liquid releases were made this quarter.

Aerage Riverflow past BFN (cubic feet per second): 20506 Population Doses Total Body Dose 0 man-rem Maximum Organ Dose (organ) 0 man-rem (organ)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

i EI-14

Radiological Impact.- ssessment Browns Ferrý'Nuclear Plant January - December 2001 Table 8 Doses from Liquid Effluents Fourth Quarter Individual Doses (mrem)

  • No liquid releases were made this quarter.

Average Riverflow past BFN (cubic feet per second): 37179 Population Doses Total Body Dose 0 man-rem Maximum Organ Dose (organ) 0 man-rem (organ)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-reminyear (based on 90 mremyr for natural background).

r EI-15 Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Total Body Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

1.5 mrem 0%

Liver Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

5 mrem 0%

Thyroid Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

5 mrem 0%

Radiological Impact Assessr-fnt Browns Ferry Nuclear P..,

January - December 2001 Table 9 Total Dose from Fuel Cycle First Second Third Fourth Dose Quarter Quarter Quarter Quarter Total Body or any Organ (except thyroid)

Total body air submersion 5 1E-03 3.1E-03 1.6E-04 2.OE-04 Cntical organ dose (air) 1.3E-02 9 OE-03 6 2E-03 I OE-02 Total body dose (liquid) 0 0

0 0

Maximum organ dose (liquid) 0 0

0 0

Direct Radiation Dose 0

0 0

0 Total 1.8E-02 1.2E-02 6.4E-03 1.0E-02 Cumulative Total Dose (mrem)

(Total body or any other organ) 4.7E-02 Annual Dose Limit (mrem) 2.SE+01 Percent of Limit

< 1%

Thyroid Dose (mrem)

Total body air submersion

5. IE-03 3.IE-03 1.6E-04 2.OE-04 Thyroid dose (airborne) 3 2E-02 3 4E-02 2.7E-02 3.2E-02 Total body dose (liquid) 0 0

0 0

Thyroid dose (liquid) 0 0

0 0

Direct Radiation Dose 0

0 0

0 Total 3.7E-02 3.7E-02 2.7E-02 3.2E-02 Cumulative Total Dose (Thyroid) mrem 1.3E-O1 Annual Dose Limit (mrem) 7.5E+01 Percent of Limit

< 1%

)

EI-16

METEORLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2001 TABLE 10 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES FIRST QUARTER E2-2

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2001 -

MAR 31, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.571 0.381 1.142 0.143 0.000 0.000 0.000 0.000 0.000 0.000 2.236 0.190 0.190 0.000 0.000 0.000 0.000 0.048 0.000 0.048 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.523 7.5-12.4 12.5-18.4 0.428 0.333 0.190 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.048 0.190 0.238 0.238 1.713 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.143 0.143 0.285 0.000 0.618 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.618 0.571 0.190 0.000 0.000 0.000 0.618 0.428 1.237 0.143 0.000 0.095 0.190 0.333 0.523 0.238 5.186 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.42 METER LEVEL DATE PRINTED: 2001/05/16 MEAN WIND SPEED =

7.61 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-3 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0 000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL 2122 1il 109 2102 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2001 -

MAR 31, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.048 0.048 0.000 0.000 0.000 0.000 0.143 0.143 0.048 0.095 0.048 0.095 0.000 0.000 0.000 0.000 0.666 0.048 0.095 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.048 0.095 0.428 7.5-12.4 12.5-18.4

0. 190 0.285 0.048 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.143 0.476 0.190 0.381 1.760 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.143 0.048 0.285 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.285 0.428 0.095 0.000 0.000 0.048 0.238

0. 143 0.095
0. 143 0.048 0.143
0. 143 0.523 0.381 0.523 3.235 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.42 METER LEVEL DATE PRINTED: 2001/05/16 40 MEAN WIND SPEED =

8.32 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 CALM 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL 2122 69 68 2102 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2001 -

MAR 31, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.095 0.190 0.143 0.000 0.000 0.000 0.000 0.000 0.000 0.476 0.095 0.000 0.000 0.048 0.000 0.000 0.095 0.048 0.000 0.048 0.048 0.095 0.048 0.048 0.048 0.000 0.618 0.333 0.285 0.048 0.000 0.000 0.238 0.000 0.048 0.048 0.000 0.000 0.000 0.048 0.095 0.000 0.048 1.189 0.190 0.333 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.190 0.143 0.190 0.571 0.381 2.046 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.143 0.143 0.381 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.42 METER LEVEL MEAN WIND SPEED =

7.78 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS 2122 100 99 2102 0

DATE PRINTED: 2001/05/16 E2-5 W] ND DI PECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.618 0.618 0.143 0.048 0.000 0.238 0.143 0.190 0.238 0.190 0.048 0.285 0.285 0.333 0.761 0.571 4.710

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2001 -

MAR 31, 2001 WIND SPEED(MPH)

CALMA 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.048 0.000 0.000 0.048 0.000 0.000 0.095 0.048 0.000 0.048 0.000 0.000 0.000 0.285 0.095 0.238 0.285 0.381 0.809 0.523 0.666 0.618 0.285 0.285 0.333 0.428 0.476 0.095 0.190

0. 190 5.899 0.951 1.189 0.523 0.523 0.951 0.856 1.189 0.856 0.285 0.000 0.095 0.190 0.714 0.523 0.381 0.333 9.562 0.571 0.999 0.714 0.285 0.285 0.143 0.285 0.095 0.190 0.000 0.095 0.048 0.476 0.523 0.666 0.476 5.852 7.5-12.4 12.5-18.4 0.951 1.332 0.523 0.000 0.000 0.000 0.048 0.000 0.095 0.143 0.048 0.238 0.666 1.570 3.663 1.618 10.894 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 0.095 0.143 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.048 0.333 1.998 0.285 3.045 2122 769 754 2102 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.42 METER LEVEL DATE PRINTED: 2001/05/16 MEAN WIND SPEED =

7.02 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-6 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.048 0.000 0.000 0.048 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.095 0.095 0.048 0.333

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 2.712 3.901 2.141 1.284 2.046 1.522 2.236 1.570 0.856 0.523

0. 618 0.951 2.426 3.140 6.993 2.950 35.871 TOTAL TOTAL TOTAL

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2001 -

MAR 31, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 WIND DI RECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 1.047 0.476 0.333 0.666 0.285 0.618 1.189 0.761 0.523 0.048 0.190 0.333 0.476 0.381 0.190 0.618 8.135 0.999 0.666 0.523 0.381 0.428 0.618 0.904 0.476 0.856 0.428

0. 095 0.048 0.618 0.333 0.666 0.666 8.706 0.809 0.523 0.571 0.048 0.000 0.095 0.618 0.428 0.285 0.143 0.190 0.095 0.285 0.238 0.618 0.523 5.471 7.5-12.4 12.5-18.4 0.523 0.333 0.095 0.000 0.000 0.048 0.048 0.000 0.285 0.143 0.000 0.000 0.190 0.333 1.475 0.904 4.377 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.095 0.143 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 3.425 2.046 1.570 1.142 0.761 1.380 2.902 1.713 2.141 0.856 0.571 0.618 1.618 1.284 3.045 2.807 27.878 HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.42 METER LEVEL DATE PRINTED: 2001/05/16 MEAN WIND SPEED =

4.90 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-7 0.048 0.048 0.048 0.048 0.048 0.000 0.143 0.048 0.190 0.095 0.095 0.095 0.048 0.000 0.095 0.000 1.047 CALM 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL TOTAL 2122 587 586 2102 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2001 -

MAR 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 WIND HTRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.761 0.476 0.238 0.048 0.381 0.809 1.237 1.237 0.856 0.238 0.095 0.048 0.143 0.095 0.190 0.381 7.231 0.666 0.714 0.143 0.285 0.143 0.095 0.714 0.476 0.476 0.048 0.000 0.000 0.000 0.000 0.523 0.571 4.853 0.190 0.238 0.190 0.000 0.000 0.000 0.048 0.428 0.571 0.190 0.000 0.000 0.000 0.000 0.000 0.048 1.903 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.143 0.285 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.476 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.665 1.522 0.571 0.333 0.571 1.094 2.141 2.569 2.569 0.761 0.190 0.095 0.238 0.143 0.856 1.047 16.365 2122 344 344 2102 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant 9TABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.42 METER LEVEL DATE PRINTED: 2001/05/16 MEAN WIND SPEED =

3.56 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-8 0.048 0.095 0.000 0.000 0.048 0.190 0.143 0.285 0.333 0.285 0.095 0.048 0.095 0.048 0.143 0.000 1.855

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant JAN 1,

2001 -

MAR 31, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 WIND DIPECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.618 0.143 0.095 0.095 0.143 0.238 0.618 1.665 0.476 0.000 0.000 0.000 0.000 0.143 0.190 0.333 4.757 0.381 0.095 0.048 0.000 0.095 0.000 0.000 0.285 0.048 0.000 0.000 0.000 0.000 0.000 0.048 0.048 1.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.048 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.094 0.238 0.190 0.095 0.238 0.381 0.666 2.141 0.618 0.048 0.048 0.000 0.000 0.190 0.381 0.428 6.755 HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.42 METER LEVEL DATE PRINTED: 2001/05/16 MEAN WIND SPEED =

2.48 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-9 0.095 0.000 0.048 0.000 0.000 0.143 0.048 0.190 0.095 0.000 0.048 0.000 0.000 0.048 0.143 0.048 0.904 CALN 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL TOTAL 2122 142 142 2102 0

METEORLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2001 TABLE 11 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES SECOND QUARTER Is E2-10

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry NP (new sensor)

APR 1, 2001 -

JUN 30, 2001 CAL0 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0 000 0.188 0.518 0.801 0.236 0.000 0.000 0.000 0.000 0.000 0.000 1.743 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A 0.000 0.000 0.000 0.000 0.000 0.094 1.978 0.895 0.848 0.236 0.283 0.330 0.047 0.000 0.000 0.000 4.710 0.000 0.000 0.000 0.000 0.000 0.141 0.141 0.000 0.000 0.000 0.000 0.283 0.141 0.000 0.000 0.000 0.707 7.5-12.4 12.5-18.4 0.518 0.188 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.236 0.236 1.225 OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.236 0.047 0.283 2133 185 184 2123 0

METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2001/08/17 MEAN WIND SPEED =

5.28 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-11 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.518 0.188 0.000 0.000 0.000 0.236 2.308 1.413 1.649 0.471 0.283 0.612 0.236 0.000 0.471 0.283 8.667 TOTAL TOTAL TOTAL HOURS HOURS HOURS

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Browns Ferry NP (new sensor)

APR 1, 2001 -

JUN 30, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.377 0.236 0.330 0.236 0.141 0.000 0.000 0.000 0.000 0.000 1.319 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B 0.000 0.000 0.000 0.000 0.000 0.047 0.471 0.141 0.094 0.236 0.141 0.330 0.141 0.000 0.000 0.000 1.602 0.094 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.283 0.330 0.000 0.000 0.000 0.801 0.377 0.047 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.094 0.141 0.330 0.236 0.188 1.507 OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.141 0.047 0.000 0.188 2133 115 115 2123 0

METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

6.09 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/08/17 E2-12 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.471 0.141 0.047 0.000 0.000 0.094 0.848 0.377 0.424 0.471 0.283 0.707 0.612 0.471 0.283 0.188 5.417 TOTAL TOTAL TOTAL HOURS HOURS HOURS

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION F0y STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry NP (new sensor)

APR 1, 2001 -

JUN 30, 2001 CALIe 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.094 0.188 0.424 0.188 0.094 0.188 0.094 0.000 0.000 0.000 0.000 1.272 0.000 0.047 0.000 0.000 0.094 0.330 0.283 0.188 0.236 0.094 0.188 0.094 0.047 0.047 0.047 0.000 1.696 0.283 0.141 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.047 0.000 0.094 0.236 0.236 0.236 0.094 1.460 0.094 0.188 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.188 0.236 0.094 0.094 0.942 OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.188 0.000 0.000 0.188 2133 118 118 2123 0

DATE PRINTED: 2001/08/17 MEAN WIND SPEED =

5.76 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-13 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL TOTAL TOTAL 0.377 0.377 0.000 0.000 0.094 0.471 0.471 0.612 0.471 0.236 0.377 0.330 0.471 0.707 0.377 0.188 5.558 HOURS HOURS HOURS HOURS HOURS

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry NP (new sensor)

APR 1, 2001 -

JUN 30, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.188 0.283 0.377 0.000 0.565 1.225 1.649 1.554 1.978 1.130 0.942 1.083 0.377 0.141 0.047 0.141 11.682 0.707 0.565 0.141 0.471 0.612 0.518 0.565 0.471 2.025 0.942 0.141 0.942 1.366 0.424 0.424 0.471 10.787 0.518 0.612 0.094 0.047 0.094 0.612 0.094 0.000 0.377 0.236 0.000 0.188 0.895 0.236 0.236 0.565 4.805 7.5-12.4 12.5-18.4 0.612 0.283 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.000 0.141 0.283 0.612

0. 659 0.424 3.156 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.188 0.424 0.000 0.612 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.025 1.743 0.707 0.518 1.272 2.355 2.308 2.120 4.428

2. 402 1.083 2.355 2.920 1.602 1.790
1. 602 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.094 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.188 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

4.68 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS 2133 667 663 2123 0

DATE PRINTED: 2001/08/17 E2-14 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 31.229

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry NP (new sensor)

APR 1, 2001 -

JUN 30, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.471 0.424 0.424 0.424 1.743 2.967 1.507 2.025 2.025 0.848 0.424 0.707 0.424 0.094 0.094 0.424 15.026 0.330 0.330 0.000 0.424 1.036 1.225 0.518 0.236 1.366 0.236 0.000 0.330 0.471 0.047 0.330 0.612 7.489 0.141 0.094 0.094 0.047 0.000 0.094 0.188 0.000 0.424 0.000 0.000 0.000 0.000 0.000 0.236 0.471 1.790 7.5-12.4 12.5-18.4 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.047 0.236 0.188 0.565 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.989 0.942 0.754 1.083 2.967 4.569 2.402 2.638 4.004 1.272 0.424 1.083 1.036 0.283 0.895 1.743 27.084 HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2001/08/17 MEAN WIND SPEED =

3.20 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-15 0.000 0.094 0.236 0.188 0.188 0.283 0.188 0.377 0.141 0.188 0.000 0.047 0.141 0.094 0.000 0.047 2.214 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL TOTAL 2133 577 575 2123 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry NP (new sensor)

APR 1, 2001 -

JUN 30, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.188 0.141 0.236 0.000 0.141 0.236 0.094 0.330 0.141 0.047 0.141 0.094 0.094 0.047 0.047 0.188

2. 167 0.754 0.565 0.141 0.518 1.083 1.130 0.612 0.612 0.707 0.188 0.094 0.000 0.047 0.047 0.094 0.283 6.877 0.801 0.471 0.047 0.141 0.565 0.094 0.000 0.000 0.424 0.000 0.000 0.000 0.000 0.000 0.000 0.471 3.015 0.047 0.094 0.047 0.000 0.000 0.000 0.000 0.000 0.236 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.518 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

2.77 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS 2133 270 268 2123 0

DATE PRINTED: 2001/08/17 E2-16 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

  • 4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.790 1.272 0.471 0.659 1.790 1.460 0.707 0.942 1.554 0.283 0.236 0.094 0.141 0.094 0.141 0.989

12. 624

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry NP (new sensor)

APR 1, 2001 -

JUN 30, 2001 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SIUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(I 0.6-1.4 1.5-3.4 3.5-5.4 0.518 0.236 0.236 0.188 0.000 0.047 0.283 0.141 0.047 0.000 0.047 0.047 0.094 0.094 0.141 0.377 2.496 1.272 0.330 0.330 0.471 0.377 0.094 0.141 0.848 0.659 0.047 0.000 0.000 0.047 0.047 0.094 0.801 5.558 0.801 0.141 0.000 0.094 0.047 0.000 0.000 0.047 0.188 0.000 0.000 0.000 0.000 0.047 0.000 0.000 1.366 5.5-7.4 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2133 201 200 2123 0

DATE PRINTED: 2001/08/17 MEAN WIND SPEED =

2.22 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-17 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 2.591 0.707 0.565 0.754 0.424 0.141 0.424 1.036

0. 895 0.047 0.047 0.047 0.141 0.188 0.236 1.178 9.421

METEORLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2001 TABLE 12 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES THIRD QUARTER

.5 E2-18

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry NP (new sensor)

JUL 1, 2001 -

SEP 30, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.460 1.563 1.149 0.506 0.138 0.000 0.000 0.000 0.000 0.000 3.814 0.046 0.000 0.000 0.000 0.092 0.368 1.149 1.057 0.965 0.322 0.230 0.551 0.092 0.000 0.000 0.000 4.871 0.092 0.046 0.000 0.000 0.000 0.276 0.092 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.092 0.689 0.781 0.735 0.046 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.138 0.046 0.276 2.160 OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2177 251 251 2176 0

METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

4.88 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/12/18 N'I*--

E2-19 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL TOTAL TOTAL 0.919 0.781 0.046 0.000 0.184 0.643 1.700 2.619 2.114 0.827 0.368 0.551 0.230 0.138 0.046 0.368 11.535 HOURS HOURS HOURS HOURS HOURS

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry NP (new sensor)

JUL 1, 2001 -

SEP 30, 2001 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.276 0.184 0.735 0.230 0.184 0.046 0.046 0.000 0.000 0.000 1.700 0.000 0.000 0.000 0.000 0.000 0.276 0.276 0.138 0.276 0.046 0.138 0.368 0.184 0.046 0.046 0.046 1.838 0.322 0.138 0.000 0.000 0.046 0.138 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.184 0.368 1.287 7.5-12.4 12.5-18.4 18.5-24.4 0.276 0.276 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.138 0.184 0.092 1.057 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.597 0.414 0.000 0.046 0.092 0.414 0.551 0.322 1.011 0.276 0.322 0.460 0.230 0.230 0.414 0.506 5.882 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

5.13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS 2177 128 128 2176 0

DATE PRINTED: 2001/12/18 E2-20 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 CALA 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry NP (new sensor)

JUL 1, 2001 -

SEP 30, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.046 0.000 0.000 0.000 0.000 0.000 0.276 0.460 0.460 0.322 0.230 0.138 0.046 0.000 0.000 0.000 1.976 0.092 0.138 0.000 0.046 0.092 0.046 0.276 0.230 0.046 0.046 0.000 0.138 0.276 0.000 0.092 0.138 1.654 0.322 0.322 0.092 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.138 0.184 0.138 0.184 1.471 7.5-12.4 12.5-18.4 0.000 0.092 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.184 0.138 0.046 0.046 0.597 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.460 0.551

0. 138 0.092 0.138 0.046 0.551 0.689 0.506 0.368 0.230 0.322 0.643 0.322 0.276 0.414 5.744 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2001/12/18 MEAN WIND SPEED =

4.90 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-21 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 CALM 0.000 0.000 0.000 0.000 0.000

-. =-.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL HOURS HOURS HOURS 2177 125 125 2176 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry NP (new sensor)

JUL 1, 2001 -

SEP 30, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.046 0.000 0.000 0.046 0.000 0.046 0.092 0.138 0.184 0.092 0.184 0.000 0.092 0.000 0.000 0.000 0.368 0.184 0.184 0.368 0.506 0.827 1.287 2.757 4.044 3.539 1.884 1.930 0.689 0.184 0.138 0.184 CALM 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0.597 0.643 0.322 0.368 0.506 0.873 0.781 0.827 0.735 0.368 0.000 0.919 1.379 0.414 0.322 0.368 9.421 0.506 0.230 0.184 0.092 0.414 0.184 0.000 0.000 0.000 0.000 0.000 0.092 0.230 0.414 0.184 0.368 2.895 7.5-12.4 12.5-18.4 0.184 0.368 0.046 0.046 0.092 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.230 0.092 0.414 1.608 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.092 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 34.007 HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2001/12/18 MEAN WIND SPEED =

3.60 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-22 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.919 19.072 TOTAL 1.700 1.425 0.735 0.919 1.517 1.976 2.160 3.722 4.963 3.998 2.068 2.941 2.482 1.241 0.735 1.425 TOTAL TOTAL TOTAL TOTAL TOTAL 2177 741 740 2176 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FO STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry NP (new sensor)

JUL 1, 2001 - SEP 30, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.092 0.092 0.138 0.414 0.184 0.322 0.551 0.460 0.276 0.368 0.276 0.184 0.184 0.184 0.138 0.184 4.044 0.689 0.597 0.643 0.781 1.471 1.241 1.287 0.735 0.827 0.689 0.643 0.919 0.322 0.322 0.138 0.597 11.903 0.643 0.735 0.138 0.184 0.873 0.506 0.138 0.000 0.092 0.092 0.000 0.138 0.230 0.000 0.046 0.460 4.274 0.138 0.735 0.138 0.000 0.092 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.322 1.563 7.5-12.4 12.5-18.4 18.5-24.4 0.092 0.138 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.276 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.654 2.298 1.057 1.379 2.619 2.114 1.976

1. 195 1.195 1.149 0.919 1.241 0.781 0.551 0.414 1.563 22.105 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2001/12/18 MEAN WIND SPEED =

2.85 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-23 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW

';UBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL 2177 481 481 2176 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry NP (new sensor)

JUL 1, 2001 -

SEP 30, 2001 CALM WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 0.138 0.092 0.138 0.230 0.276 0.092 0.138 0.092 0.092 0.046 0.046 0.092 0.046 0.046 0.000 0.230 1.792 0.965 0.919 1.103 1.517 1.563 0.322 0.046 0.138 0.046 0.046 0.046 0.000 0.000 0.092 0.000 0.506 7.307 0.781 0.551 0.184 0.551 0.597 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 2.757 0.000 0.138 0.138 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.276 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.884 1.700 1.563 2.298 2.436 0.460 0.184 0.230 0.138 0.092 0.092 0.092 0.092 0.138 0.000 0.781 12.178 2177 265 265 2176 0

METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2001/12/18 MEAN WIND SPEED =

2.75 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-24 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL HOURS HOURS HOURS

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

CALM 0.016 0.007 0.007 0.005 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.001 0.005 0.046 Browns Ferry NP (new sensor)

JUL 1, 2001 -

SEP 30, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 1.654 0.551 0.827 0.597 0.230 0.046 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 0.322 4.320 1.057 0.322 0.000 0.276 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.184 1.930 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2177 186 186 2176 1

DATE PRINTED: 2001/12/18 MEAN WIND SPEED =

2.37 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-25

0. 689 0.460 0.138 0.184 0.092 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.092 0.092 0.460 2.252 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL TOTAL TOTAL 3.417 1.340 0.972 1.062 0.370 0.046 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.093 0.185 0.971 8.548 HOURS HOURS HOURS HOURS HOURS

METEORLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2001 TABLE 13 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES FOURTH QUARTER E2-26

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2001 -

DEC 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 WI ND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.138 0.092 0.000 0.046 0.000 0.000 0.000 0.000 0.321 0.000 0.000 0.000 0.000 0.046 0.000 0.229 0.918 0.413 0.459 0.138 0.046 0.000 0.000 0.000 0.046 2.295 0.000 0.000 0.000 0.000 0.000 0.459 0.046 0.000 0.000 0.000 0.046 0.046 0.138 0.000 0.000 0.046 0.780 7.5-12.4 12.5-18.4 0.688 0.367 0.046 0.000 0.000 0.138 0.000 0.000 0.000 0.000 0.000 0.092 0.184 0.184 0.275 0.597 2.570 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 0.046 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.138 0.229 0.000 0.505 2179 142 142 2179 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/02/12 MEAN WIND SPEED =

7.68 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-27 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.734 0.459 0.046 0.000 0.046 0.597 0.275 0.964 0.551 0.551 0.184 0.229 0.321 0.321 0.551

0. 688 6.517 TOTAL TOTAL TOTAL HOURS HOURS HOURS

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR' STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/l00 M)

Browns Ferry Nuclear Plant OCT 1, 2001 -

DEC 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.184 0.046 0.000 0.000 0.000 0.000 0.138 0.184 0.000 0.184 0.184 0.092 0.046 0.000 0.046 0.000 0.000 0.918 0.046

0. 138 0.000 0.000 0.000 0.184 0.092 0.046 0.000 0.000 0.000 0.046 0.000 0.138 0.138 0.000 0.826 0.321 0.184 0.229 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046
0. 184 0.275 0.184 0.092 1.606 OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.184 0.092 0.000 0.275 2179 83 83 2179 0

DATE PRINTED: 2002/02/12 MEAN WIND SPEED =

7.72 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-28 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.413 0.321 0.229 0.046 0.000 0.321 0.321 0.046 0.275 0.229 0.138 0.138 0.184 0.642 0.413 0.092 3.809 HOURS HOURS HOURS HOURS HOURS

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2001 -

DEC 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.184 0.184 0.046 0.184 0.046 0.000 0.000 0.046 0.000 0.734 0.138 0.138 0.000 0.000 0.000 0.000 0.459 0.046 0.459 0.000 0.046 0.092 0.092 0.138 0.184 0.046 1.836 0.184 0.275 0.092 0.000 0.046 0.000 0.046 0.046 0.000 0.000 0.000 0.138 0.000 0.046 0.000 0.321 1.193 7.5-12.4 12.5-18.4 18.5-24.4 0.092 0.138 0.229 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.092 0.229 0.092 0.138 1.056 OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2179 106 106 2179 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/02/12 MEAN WIND SPEED =

5.74 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-29 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL TOTAL TOTAL 0.413 0.551 0.321 0.000 0.046 0.000

0. 597 0.275 0.642 0.046 0.229 0.275 0.184 0.459 0.321 0.505 4.865 HOURS HOURS HOURS HOURS HOURS

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2001 -

DEC 31, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.092 0.046 0.046 0.000 0.000 0.000 0.000 0.229 0.092 0.275 0.046 0.367 0.413 0.229 0.688 1.285 1.147 0.826 0.367 0.229 0.275 0.229 0.138 0.184 6.792 0.734 0.505 0.229 0.138 0.229 1.056 0.780 1.101 1.147 0.367 0.046 0.321 0.413 0.367 0.459 0.229 8.123 0.367 0.505 0.138 0.275 0.000 0.964 0.229 0.046 0.184 0.138 0.138 0.413 0.275 0.459 0.184 0.229 4.543 7.5-12.4 12.5-18.4 18.5-24.4 0.918 0.275 0.184 0.000 0.046 0.367 0.413 0.000 0.184 0.000 0.046 0.092 0.321 0.413 0.826 0.459 4.543 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.092 0.275 0.918 0.092 1.423 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.046 0.000 0.138

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.111 1.560 0.597 0.780 0.688 2.616 2.111 2.432 2.708 1.423 0.642 1.147 1.377 1.836 2.570 1.193 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 6.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/02/12 MEAN WIND SPEED =

5.80 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-30 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 25.792 TOTAL TOTAL TOTAL TOTAL TOTAL 2179 562 562 2179 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2001 -

DEC 31, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.459 0.184 0.505 0.275 0.321 0.826 1.193 1.514 1.239 0.321 0.138 0.505 0.321 0.229 0.321 0.413 8.765 0.551 0.413 0.138 0.092 0.321 1.514 1.239 1.698 1.423 0.367 0.138 0.092 0.229 0.000 0.505 0.367 9.087 0.321 0.092 0.138 0.000 0.000 0.734 0.367 0.597 0.597 0.046 0.046 0.000 0.229 0.000 0.229 0.321 3.717 7.5-12.4 12.5-18.4 0.229 0.092 0.000 0.000 0.000 0.046 0.092 0.184 0.367 0.046 0.000 0.000 0.092 0.138 0.459 0.275 2.019 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.138 0.000 0.184 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.092 0.046 0.321 0.229 0.000 0.138 0.046 0.000 0.138 0.046 0.000 0.000 1.101 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/02/12 MEAN WIND SPEED =

4.37 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-31 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 24.874 TOTAL 1.606 0.780 0.780 0.367 0.734 3.167 3.212 4.222 3.626 0.918 0.367 0.597 1.010 0.459 1.652 1.377 TOTAL TOTAL TOTAL 2179 542 542 2179 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2001 -

DEC 31, 2001 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.918 0.321 0.229 0.597 0.872 1.423 1.606 1.010 0.551 0.184 0.046 0.046 0.000 0.138 0.321 0.642 8.903 1.010 1.147 0.184 0.046 0.597 0.413 0.321 0.505 0.321 0.000 0.000 0.000 0.000 0.000 0.229 0.734 5.507 0.138 0.275 0.229 0.046 0.000 0.000 0.046 0.367 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.138 1.331 7.5-12.4 12.5-18.4 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.138 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.275 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.138 0.184 0.275 0.138 0.092 0.229 0.275 0.138 0.092 0.000 0.000 0.092 0.046 0.092 0.000 1.836 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/02/12 MEAN WIND SPEED =

3.21 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-32 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 17.852 TOTAL 2.111 1.973 0.826 0.964 1.606 1.927 2.203 2.157 1.193 0.275 0.046 0.046 0.092 0.184 0.734 1.514 TOTAL TOTAL TOTAL 2179 389 389 2179 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2001 -

DEC 31, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.780 0.413 0.459 0.229 0.413 0.275 0.367 0.505 0.092 0.092 0.000 0.092 0.138 0.092 0.229 0.367 4.543 1.973 0.734 1.377 1.193 0.918 0.229 0.229 0.597 0.275 0.000 0.000 0.000 0.000 0.092 0.459 1.056 9.133 1.331 0.321 0.046 0.184 0.092 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.275 2.386 0.046 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.138 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0'.000 0.000 0.000 4.149 1.568 1.894 1.616 1.432 0.508 0.601 1.201 0.370 0.092 0.000 0.092 0.139 0.185 0.739 1.708 CALM 0.018 0.008 0.012 0.010 0.009 0.003 0.004 0.007 0.002 0.001 0.000 0.001 0.001 0.001 0.005 0.010 0.092 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/02/12 MEAN WIND SPEED =

2.24 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-33 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 16.292 TOTAL TOTAL TOTAL 2179 355 355 2179 2

METEORLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2001 TABLE 14 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL PORTION)

FIRST QUARTER E2-34

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2001 -

MAR 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.044 0.019 0.078 0.015 0.000 0.000 0.000 0.000 0.000 0.000 0.157 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 0.017 0.018 0.000 0.000 0.000 0.000 0.009 0.000 0.009 0.000 0.000 0.007 0.000 0.000 0.000 0.000 0.060 7.5-12.4 12.5-18.4 0.072 0.047 0.033 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.006 0.032 0.042 0.026 0.269 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

-.0.042 0.030 0.058 0.000 0.130 1962.000 214.750 12.070 12.070 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.42 METER LEVEL WIND SPEED MEASURED AT 10.42 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/05/16 E2-35 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL

>=2 4. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS TOTAL 0.089 0.065 0.033 0.000 0.000 0.000 0.054 0.019 0.087 0.015 0.000 0.017 0.048 0.062 0.100 0.026 0.615

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2001 -

MAR 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.001 0.000 0.000 0.000 0.000 0.003 0.000 0.009 0.007 0.000 0.003 0.000 0.000 0.000 0.000 0.023 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 0.003 0.008 0.000 0.000 0.000 0.000 0.015 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.004 "0.008 0.046 7.5-12.4 12.5-18.4 0.027 0.047 0.008 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.025 0.072 0.034 0.067 0.291 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.013 0.030 0.010 0.062 1962.000 214.750 8.300 8.300 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.42 METER LEVEL WIND SPEED MEASURED AT 10.42 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/05/16 E2-36 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.031 0.056 0.017 0.000 0.000 0.010 0.018 0.000 0.009 0.007 0.000 0.011 0.025 0.086 0.067 0.085 0.423

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1,

2001 -

MAR 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.000 0.000 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.012 0.000 0.000 0.000 0.001 0.000 0.000 0.000 0.002 0.000 0.007 0.005 0.000 0.000 0.000 0.000 0.000 0.015 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 0.031 0.021 0.004 0.000 0.000 0.041 0.000 0.010 0.009 0.000 0.000 0.000 0.005 0.007 0.000

"*0.005 0.133 7.5-12.4 12.5-18.4 0.031 0.049 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.028 0.022 0.030 0.081 0.053 0.302 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.012 0.000 0.020 0.020 0.063 1962.000 214.750 11.940 10.290 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.42 METER LEVEL WIND SPEED MEASURED AT 10.42 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/05/16 E2-37 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.061 0.071 0.022 0.001 0.000 0.041 0.005 0.012 0.009 0.014 0.005 0.028 0.039 0.037 0.101 0.078 0.524

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2001 -

MAR 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH)

0. -1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.002 0.012 0.022 0.017 0.005 0.001 0.005 0.001 0.004 0.000 0.000 0.000 0.070 0.049 0.047 0.014 0.016 0.064 0.072 0.213 0.106 0.017 0.000 0.008 0.006 0.038 0.006 0.007 0.013 0.674 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 0.072 0.120 0.076 0.027 0.037 0.024 0.117 0.000 0.024 0.000 0.020 0.008 0.051 0.031 0.054 "0.056 0.717 7.5-12.4 12.5-18.4 0.167 0.235 0.083 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.015 0.047 0.118 0.246 0.589 0.262 1.808 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 1962.000 214.750 1013.900 80.120 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.42 METER LEVEL WIND SPEED MEASURED AT 10.42 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS'AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/05/16 E2-38 0.030 0.021 0.020 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.049 0.018 0.055 0.523 0.032 0.748 TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0:000 0.000 0.000 0.000 0.000 0.067 0.000 0.000 0.067 HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.318 0.423 0.193 0.045 0.103 0.108 0.398 0.122 0.046 0.001 0.047 0.112 0.229 0.404 1.173 0.362 4.084

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2001 -

MAR 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.026 0.011 0.012 0.010 0.003 0.028 0.048 0.030 0.019 0.005 0.005 0.010 0.015 0.008 0.002 0.009 0.241 0.098 0.068 0.044 0.037 0.051 0.091 0.139 0.088 0.136 0.037 0.012 0.007 0.064 0.032 0.057 0.063 1.024 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 0.135 0.075 0.087 0.006 0.000 0.017 0.186 0.179 0.019 0.019 0.029 0.008 0.043 0.028 0.094

'0.077 1.002 7.5-12.4 12.5-18.4 0.084 0.068 0.017 0.000 0.000 0.015 0.038 0.000 0.019 0.000 0.000 0.000 0.035 0.060 0.264 0.134 0.734 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.011 0.011 1962.000 214.750 698.170 59.280 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.42 METER LEVEL WIND SPEED MEASURED AT 10.42 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/05/16 E2-39 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.343 0.222 0.161 0.052 0.054 0.151 0.412 0.297 0.202 0.062 0.046 0.025 0.157 0.127 0.416 0.293 3.021

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2001 -

MAR 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.009 0.006 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.020 0.041 0.020 0.014 0.000 0.013 0.062 0.101 0.133 0.101 0.017 0.003 0.006 0.006 0.006 0.010 0.015 0.548 0.092 0.096 0.019 0.042 0.022 0.017 0.121 0.096 0.074 0.000 0.000 0.000 0.000 0.000 0.062 0.060 0.702 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 0.031 0.044 0.034 0.000 0.000 0.000 0.000 0.062 0.017 0.000 0.000 0.000 0.000 0.000 0.000 "0.007 0.195 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.153 0.153 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.315 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1962.000 214.750 181.340 35.930 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.42 METER LEVEL WIND SPEED MEASURED AT 10.42 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-40 DATE PRINTED: 2001/05/16 4.

OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.164.

0.160 0.068 0.042 0.035 0.079 0.224 0.453 0.402 0.020 0.003 0.006 0.006 0.006 0.072 0.092 1.831

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2001 -

MAR 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4,

5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.013 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.018 0.022 0.000 0.000 0.000 0.004 0.014 0.050 0.170 0.058 0.000 0.000 0.000 0.000 0.010 0.011 0.007 0.346 0.042 0.011 0.006 0.000 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.008 0.083 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 "0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1962.000 214.750 36.280 8.760 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.42 METER LEVEL WIND SPEED MEASURED AT 10.42 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/05/16 E2-41 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.064 0.011 0.006 0.000 0.015 0.014 0.052 0.183 0.061 0.000 0.000 0.000 0.000 0.010 0.016 0.015 0.446

METEORLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2001 TABLE 15 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL PORTION)

SECOND QUARTER E2-42

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry NP (new sensor)

PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2001 -

JUN 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.060 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.029 0.053 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.000 0.000 0.000 0.000 0.000 0.012 0.159 0.052 0.074 0.018 0.024 0.026 0.007 0.000 0.000 0.000 0.371 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 0.000 0.000 0.000 0.000 0.000 0.024 0.021 0.000 0.000 0.000 0.000 0.037 0.014 0.000 0.000

"*0.000 0.096 7.5-12.4 12.5-18.4 0.087 0.030 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.000 0.041 0.042 0.206 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.052 0.009 0.062 2122.000 190.480 17.590 17.590 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/08/17 E2-43 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.087 0.030 0.000 0.000 0.000 0.035 0.185 0.081 0.127 0.026 0.024 0.063 0.027 0.000 0.093 0.052 0.829

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry NP (new sensor)

PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2001 -

JUN 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.025 0.007 0.020 0.006 0.001 0.000 0.000 0.000 0.000 0.000 0.058 0.000 0.000 0.000 0.000 0.000 0.005 0.021 0.008 0.015 0.031 0.007 0.012 0.006 0.000 0.000 0.000 0.105 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 0.009 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.033 0.000 0.000

"*0.000 0.091 7.5-12.4 12.5-18.4 18.5-24.4 0.062 0.006 0.008 0.000 0.000 0.015 0.000 0.000 0.000 0.000 0.000 0.017 0.021 0.050 0.035 0.030 0.243 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.028 0.009 0.000 0.037 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2122.000 190.480 11.340 11.340 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/08/17 E2-44 WIND OIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.071 0.016 0.008 0.000 0.000 0.020 0.045 0.015 0.034 0.037 0.008 0.068 0.060 0.078 0.044 0.030 0.534

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry NP (new sensor)

PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2001 -

JUN 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4' 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.001 0.010 0.004 0.008 0.005 0.000 0.000 0.000 0.000 0.000 0.029 0.000 0.001 0.000 0.000 0.000 0.031 0.026 0.001 0.041 0.007 0.010 0.012 0.000 0.000 0.000 0.000 0.129 VALID OBSERVATIONS GROUND LEVEL RELEASE STABILITY CLASS C GROUND LEVEL STABILITY CLASS C 0.028 0.016 0.000 0.000 0.000 0.008 0.000 0.000 0.010 0.015 0.000 0.013 0.027 0.015 0.017 0.159 7.5-12.4 12.5-18.4 18.5-24.4 0.014 0.025 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.032 0.035 0.016 0.013 0.145 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2122.000 190.480 14.510 10.760 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/08/17 E2-45 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 OF OF OF OF TOTAL 0.042 0.042 0.000 0.000 0.000 0.039 0.027 0.011 0.055 0.030 0.015 0.033 0.059 0.095 0.034 0.023 0.507

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry NP (new sensor)

PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2001 -

JUN 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.*000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 oFo 0.000 0.000 0.001 0.000 0.001 0.030 0.066 0.060 0.171 0.018 0.012 0.013 0.001 0.000 0.000 0.000 0.374 0.026 0.014 0.000 0.019 0.039 0.067 0.086 0.093 0.352 0.159 0.012 0.072 0.069, 0.005 0.006 0.009 1.029 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 0.053 0.057 0.011 0.006 0.015 0.123 0.029 0.000 0.087 0.077 0.000 0.027 0.106 0.010 0.024

'0.052 0.676 7.5-12.4 12.5-18.4 18.5-24.4 0.115 0.041 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.076 0.000 0.026 0.045 0.099 0.117 0.071 0.598 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.042 0.188 0.000 0.230 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2122.000 190.480 1042.420 61.720 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/08/17 E2-46 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.194 0.112 0.020 0.025 0.056 0.221 0.180 0.154 0.610 0.331 0.024 0.138 0.221 0.156 0.335 0.132 2.909

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry NP (new sensor)

PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2001 - JUN 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.002 0.004 0.003 0.007 0.000 0.009 0.005 0.000 0.004 0.000 0.000 0.000 0.000 0.033 0.013 0.014 0.003 0.012 0.070 0.158 0.096 0.196 0.210 0.069 0.014 0.010 0.008 0.000 0.003 0.003 0.880 0.025 0.026 0.000 0.042 0.110 0.171 0.083 0.054 0.251 0.062 0.000 0.033 0.036 0.001 0.019 0.054 0.969 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 0.020 0.014 0.014 0.005 0.000 0.019 0.038 0.000 0.190 0.000 0.000 0.000 0.000 0.000 0.036 "0.070 0.405 7.5-12.4 12.5-18.4 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.008 0.041 0.034 0.102 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2122.000 190.480 780.430 50.710 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/08/17 Is E2-47 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.066 0.055 0.017 0.061 0.185 0.350 0.224 0.250 0.671 0.136 0.014 0.048 0.044 0.009 0.100 0.162 2.390

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry NP (new sensor)

PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2001 -

JUN 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.005 0.000 0.005 0.000 0.010 0.015 0.003 0.036 0.005 0.000 0.011 0.004 0.000 0.000 0.000 0.001 0.095 0.053 0.026 0.000 0.016 0.068 0.082 0.044 0.066 0.097 0.003 0.004 0.000 0.000 0.000 0.005 0.011 0.475 0.103 0.063 0.006 0.013 0.068 0.012 0.000 0.000 0.077 0.000 0.000 0.000 0.000 0.000 0.000 0.066 0.408 VALID OBSERVATIONS GROUND LEVEL RELEASE STABILITY CLASS F GROUND LEVEL STABILITY CLASS F 0.008 0.015 0.008 0.000 0.000 0.000 0.000 0.000 0.107 0.009 0.000 0.000 0.000 0.000 0.000 "0.008 0.155 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.017 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.017 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2122.000 190.480 207.510 24.400 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/08/17 E2-48 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS OF OF OF OF TOTAL 0.169 0.104 0.018 0.029 0.146 0.110 0.047 0.102 0.303 0.012 0.015 0.004 0.000 0.000 0.005 0.086 1.150

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry NP (new sensor)

PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2001 -

JUN 30, 2001 CALM 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.009 0.000 0.000 0.000 0.021 0.019 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.003 0.052 0.078 0.026 0.011 0.018 0.019 0.005 0.017 0.126 0.091 0.000 0.000 0.000 0.001 0.000 0.000 0.015 0.408 0.112 0.023 0.000 0.007 0.007 0.000 0.000 0.010 0.040 0.000 0.000 0.000 0.000 0.001 0.000 0.000 0.198 VALID OBSERVATIONS GROUND LEVEL RELEASE STABILITY CLASS G GROUND LEVEL STABILITY CLASS G 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 "0.000 0.000 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2122.000 190.480 48.200 13.960 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/08/17 E2-49 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NS W SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS OF OF OF OF TOTAL 0.190 0.049 0.021 0.025 0.025 0.005 0.038 0.155 0.131 0.000 0.000 0.000 0.001 0.001 0.000 0.018 0.658

METEORLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2001 TABLE 16 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL PORTION)

THIRD QUARTER E2-50

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry NP (new sensor)

PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2001 -

SEP 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.021 0.065 0.048 0.037 0.001 0.000 0.000 0.000 0.000 0.o000, 0.171 0.001 0.000 0.000 0.000 0.001 0.029 0.071 0.042 0.038 0.023 0.008 0.033 0.000 0.000 0.000 0.000 0.248 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 0.008 0.006 0.000 0.000 0.000 0.041 0.014 0.000 0.000 0.000 0.000 0.000 0.007 0.000 0.000 "0.007 0.083 7.5-12.4 12.5-18.4 0.124 0.120 0.008 0.000 0.014 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.021 0.008 0.046 0.350 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2142.000 125.970 18.250 18.250 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY - 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/12/18 E2-51 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL

>-24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS TOTAL 0.134 0.126 0.008 0.000 0.015 0.070 0.106 0.107 0.086 0.060 0.010 0.033 0.016 0.021 0.008 0.053 0.852

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry NP (new sensor)

PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2001 -

SEP 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.021 0.017 0.034 0.006 0.004 0.000 0.000 0.000 0.000 0.000 0.082 0.000 0.000 0.000 0.000 0.000 0.008 0.016 0.000 0.023 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.056 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 0.024 0.015 0.000 0.000 0.007 0.019 0.000 0.000 0.000 0.000 0.000 0.003 0.000 0.004 0.011 "0.021 0.104 7.5-12.4 12.5-18.4 0.039 0.043 0.000 0.007 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.021 0.027 0.014 0.159 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2142.000 125.970 9.600 8.600 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

'

-j DATE PRINTED: 2001/12/18 E2-52 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.063 0.058 0.000 0.007 0.014 0.027 0.037 0.017 0.057 0.006 0.004 0.012 0.000 0.025 0.038 0.035 0.401

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry NP (new sensor)

PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2001 -

SEP 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.016 0.012 0.009 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.002 0.000 0.001 0.008 0.005 0.006 0.016 0.008 0.000 0.000 0.000 0.003 0.000 0.001 0.002 0.055 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 0.032 0.025 0.010 0.000 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.018 0.013 0.010 "0.018 0.134 7.5-12.4 12.5-18.4 0.000 0.016 0.006 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.024 0.020 0.005 0.006 0.082 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.012 0.012 2142.000 125.970 26.470 7.040 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/12/18 E2-53 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NN-W S;UBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.032 0.043 0.015 0.007 0.013 0.005 0.022 0.028 0.017 0.008 0.000 0.006 0.045 0.033 0.016 0.038 0.329

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry NP (new sensor)

PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2001 - SEP 30, 2001 CALM 0.000 0.000 0.000 0.000 0.Q000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.028 0.081 0.157 0.254 0.165 0.009 0.010 0.001 0.000 0.000 0.000 0.707 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 0.035 0.021 0.002 0.005 0.029 0.118 0.048 0.024 0.126 0.064 0.000 0.042 0.060 0.009 0.002 0.012 0.597 0.063 0.022 0.010 0.008 0.062 0.026 0.000 0.000 0.000 0.000 0.000 0.013 0.028 0.035 0.015 "0.042 0.324 7.5-12.4 12.5-18.4 0.033 0.059 0.007 0.005 0.015 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.013 0.032 0.014 0.070 0.257 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.050 2142.000 125.970 1172.280 41.460 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/12/18 E2-54 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS TOTAL 0.130 0.103 0.020 0.019 0.108 0.180 0.129 0.181 0.380

.0.229 0.009 0.064 0.102 0.077 0.031 0.174 1.936

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry NP (new sensor)

PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2001 -

SEP 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.003 0.002 0.003 0.006 0.013 0.018 0.014 0.000 0.002 0.001 0.000 0.000 0.000 0.000 0.004 0.067 0.023 0.020 0.007 0.014 0.050 0.081 0.062 0.036 0.055 0.034 0.010 0.000 0.000 0.000 0.000 0.029 0.421 0.085 0.086 0.010 0.012 0.092 0.079 0.027 0.000 0.014 0.009 0.000 0.005 0.017 0.000 0.003 0.046 0.486 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 0.023 0.117 0.019 0.000 0.015 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.000 0.006

'0.052 0.246 7.5-12.4 12.5-18.4 0.017 0.023 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.009 2142.000 125.970 719.440 27.310 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/12/18 E2-55 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.148 0.249 0.039 0.028 0.163 0.181 0.106 0.050 0.069 0.045 0.011 0.005 0.022 0.010 0.016 0.132 1.275

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry NP (new sensor)

PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2001 -

SEP 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.001 0.007 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.014 0.049 0.040 0.030 0.028 0.077 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.016 0.251 0.115 0.090 0.023 0.054 0.066 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.360 VALID OBSERVATIONS GROUND LEVEL RELEASE STABILITY CLASS F GROUND LEVEL STABILITY CLASS F 0.000 0.026 0.023 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 "0.000 0.049 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.000 0.000 0.000 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2142.000 125.970 157.000 14.610 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/12/18 E2-56 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS OF OF OF OF TOTAL 0.164 0.156 0.078 0.090 0.148 0.013 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.000 0.000 0.024 0.682

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry NP (new sensor)

PAPT 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2001 -

SEP 30, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.096 0.020 0.018 0.006 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.013 0.156 0.160 0.043 0.000 0.015 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.022 0.244 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 "0.000 0.000 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2142.000 125.970 38.960 8.700 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/12/18 E2-57 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.004 0.000 0.000 0.000 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 TOTAL TOTAL TOTAL TOTAL

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS TOTAL 0.260 0.063 0.018 0.021 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.035 0.406

METEORLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2001 TABLE 17 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL PORTION)

FOURTH QUARTER E2-58

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2001 -

DEC 31, 2001 CALM 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.003 0.010 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.019 0.000 0.000 0.000 0.000 0.001 0.000 0.036 0.117 0.025 0.047 0.011 0.004 0.000 0.000 0.000 0.000 0.241 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 0.000 0.000 0.000 0.000 0.000 0.085 0.008 0.000 0.000 0.000 0.007 0.008 0.015 0.000 0.000 "0.005 0.128 7.5-12.4 12.5-18.4 0.123 0.066 0.007 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.016 0.029 0.027 0.045 0.100 0.460 0.009 0.019 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.044 0.047 0.000 0.120 2150.000 288.090 21.380 21.380 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2002/02/12 E2-59 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.026 0.000 0.026 HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.133 0.085 0.007 0.000 0.001 0.133 0.044 0.120 0.035 0.053 0.018 0.028 0.044 0.071 0.118 0.105 0.994

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2001 -

DEC 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.000 0.000 0.000 0.013 0.012 0.000 0.014 0.014 0.008 0.000 0.000 0.000 0.000 0.000 0.063 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 0.004 0.010 0.000 0.000 0.000 0.030 0.023 0.020 0.000 0.000 0.000 0.007 0.000 0.007 0.009 "0.000 0.110 7.5-12.4 12.5-18.4 18.5-24.4 0.057 0.030 0.035 0.009 0.000 0.000 0.011 0.000 0.000 0.000 0.000 0.008 0.028 0.042 0.024 0.016 0.260 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.057 0.034 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2150.000 288.090 11.270 11.270 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2002/02/12 E2-60 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.062 0.040 0.035 0.009 0.000 0.043 0.046 0.020 0.014 0.014 0.008 0.014 0.028 0.106 0.068 0.016 0.524

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2001 -

DEC 31, 2001 0.6-1.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.014 0.000 0.002 0.000 0.000 0.000 0.000 0.039 0.009 0.019 0.000 0.000 0.004 0.001 0.000 0.001 0.000 0.075 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 0.018 0.021 0.007 0.000 0.003 0.000 0.026 0.012 0.000 0.000 0.000 0.018 0.000 0.001 0.000

0. 022 0.127 7.5-12.4 12.5-18.4 0.015 0.021 0.033 0.000 0.000 0.000 0.013 0.000 0.000 0.000 0.000 0.000 0.011 0.031 0.013 0.024 0.162 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.000 0.000 0.010 2150.000 288.090 13.950 8.360 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2002/02/12 E2-61 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS TOTAL 0.034 0.045 0.039 0.000 0.003 0.000 0.079 0.028 0.027 0.000 0.000 0.022 0.012 0.042 0.014 0.046 0.389

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2001 -

DEC 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.009 0.015 0.048 0.062 0.021 0.003 0.005 0.000 0.000 0.000 0.000 0.166 0.041 0.019 0.002 0.000 0.012 0.156 0.116 0.250 0.227 0.065 0.007 0.016 0.019 0.008 0.012 0.002 0.952 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 0.051 0.057 0.013 0.028 0.000 0.297 0.094 0.035 0.047 0.025 0.026 0.059 0.035 0.043 0.018 "0.023 0.852 7.5-12.4 12.5-18.4 18.5-24.4 0.167 0.048 0.025 0.000 0.009 0.220 0.355 0.000 0.064 0.000 0.009 0.016 0.055 0.068 0.152 0.081 1.269 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.033 0.096 0.247 0.020 0.434 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.067 0.047 0.000 0.113 2150.000 288.090 880.320 81.390 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2002/02/12 E2-62 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL

>=2 4.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS TOTAL 0.260 0.125 0.040 0.028 0.022 0.681 0.580 0.334 0.400 0.110 0.045 0.134 0.142 0.282 0.474 0.127 3.786

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2001 -

DEC 31, 2001 WIND SPEED(MPH)

CALM' 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 d -

0.010 0.000 0.008 0.001 0.012 0.057 0.129 0.157 0.134 0.026 0.000 0.013 0.011 0.006 0.003 0.004 0.573 0.062 0.046 0.012 0.006 0.039 0.247 0.402 0.785 0.272 0.044 0.013 0.003 0.018 0.000 0.053 0.040 2.040 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 0.053 0.015 0.021 0.000 0.000 0.157 0.057 0.396 0.163 0.010 0.008 0.000 0.033 0.000 0.033 "0.052 0.999 7.5-12.4 12.5-18.4 0.043 0.017 0.000 0.000 0.000 0.010 0.045 0.180 0.278 0.009 0.000 0.000 0.015 0.026 0.088 0.050 0.761 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.029 0.000 0.038 2150.000 288.090 723.250 95.010 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTBD: 2002/02/12 W4 E2-63 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS TOTAL 0.168 0.078 0.041 0.007 0.051 0.471 0.640 1.518 0.847 0.088 0.021 0.017 0.077 0.041 0.207 0.146 4.419

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2001 -

DEC 31, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.004 0.013 0.007 0.003 0.004 0.009 0.021 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.060 0.070 0.013 0.000 0.033 0.049 0.152 0.150 0.159 0.051 0.000 0.000 0.002 0.000 0.000 0.004 0.039 0.721 0.137 0.165 0.025 0.007 0.065 0.064 0.063 0.187 0.060 0.000 0.000 0.000 0.000 0.000 0.016 0.097 0.886 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 0.023 0.046 0.040 0.008 0.000 0.000 0.010 0.325 0.020 0.000 0.000 0.000 0.000 0.000 0.007 "0.024 0.502 7.5-12.4 12.5-18.4 0.000 0.019 0.000 0.000 0.000 0.000 0.000 0.000 0.107 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.134 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2150.000 288.090 314.860 49.510 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2002/02/12 E2-64

'I..

WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL CALM 0.000 0.000 0.000 0.000 0:000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.600 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS

>-24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.230 0.246 0.077 0.055 0.117 0.220 0.231 0.691 0.238 0.000 0.000 0.002 0.000 0.000 0.036 0.160 2.303

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2001 -

DEC 31, 2001 CALM' 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.004 0.005 0.006 0.006 0.027 0.018 0.032 0.029 0.007 0.000 0.000 0.000 0.000 0.004 0.000 0.000 0.135 0.102 0.042 0.054 0.036 0.040 0.014 0.034 0.080 0.025 0.000 0.000 0.000 0.000 0.000 0.013 0.039 0.480 0.209 0.048 0.007 0.021 0.011 0.000 0.000 0.012 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.033 0.344 OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 0.008 0.018 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.026 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2150.000 288.090 184.970 21.170 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-65 DATE PRINTED: 2002/02/12 b

WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.323 0.112 0.067 0.062 0.078 0.032 0.066 0.121 0.032 0.000 0.000 0.000 0.000 0.004 0.015 0.072 0.985

METEORLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2001 TABLE 18 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (ELEVATED PORTION)

FIRST QUARTER E2-66

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-l.9 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2001 -

MAR 31, 2001 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0W000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

",0.000 0.000 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL HOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.67 METER LEVEL WIND SPEED MEASURED AT 45.67 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/05/16 E2-67 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 CALM' 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1962.000 1747.250 12.070 0.000

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2001 -

MAR 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

"*0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1962.000 1747.250 8.300 0.000 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.67 METER LEVEL WIND SPEED MEASURED AT 45.67 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/05/16 4*

E2-68 WIND bi 1U1CTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2001 -

MAR 31, 2001 CALM 0.000 0.000 0.000 0.000 Q0.Oo 0.0oo 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 VALID OBSERVATIONS ELEVATED RELEASES STABILITY CLASS C ELEVATED STABILITY CLASS C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 10.000 0.000 7.5-12.4 12.5-18.4 0.000 0.043 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.043 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.041 0.000 0.000 0.000 0.000 0.041 1962.000 1747.250 11.940 1.650 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.67 METER LEVEL WIND SPEED MEASURED AT 45.67 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/05/16 E2-69 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS OF OF OF OF TOTAL 0.000 0.043 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.041 0.000 0.000 0.000 0.000 0.084

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2001 -

MAR 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.051 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.051 0.000 0.204 0.153 0.102 0.051 0.255 0.255 0.051 0.153 0.306 0.204 0.204 0.408 0.255 0.255 0.255 0.102 0.051 3.058 0.561 0.459 0.204 0.612 0.408 0.408 0.561 0.408 0.306 0.102 0.255 0.408 0.459 0.866 0.255 0.153 6.422 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 0.492 0.988 0.542 0.197 0.592 0.881 0.393 0.249 0.245 0.048 0.049 0.345 0.592 0.497 0.391 "0.246 6.747 7.5-12.4 12.5-18.4 2.898 3.274 0.944 0.184 0.462 0.903 0.446 0.314 0.831 0.574 0.365 0.134 1.341 2.269 2.124 1.768 18.832 1.248 1.117 0.209 0.000 0.000 0.166 0.457 0.374 0.335 0.084 0.123 0.375 0.664 1.076 3.365 1.706 11.299 1962.000 1747.250 1013.900 933.780 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.67 METER LEVEL WIND SPEED MEASURED AT 45.67 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/05/16 E2-70 WI ND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.030 0.000 0.000 0.000 0.000 0.000 0.171 0.090 0.000 0.000 0.036 0.000 0.101 0.136 0.410 0.040 1.015 HOURS HOURS HOURS HOURS

>ý=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.016 TOTAL 5.432 5.939 2.002 1.247 1.717 2.409 2.191 1.747 1.921 1.062 1.235 1.516 3.412 5.100 6.698 3.964 47.593

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION-FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2001 -

MAR 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.102 0.102 0.051 0.153 0.000 0.102 0.000 0.204 0.051 0.153 0.153 0.255 0.051 0.153 0.153 0.051 0.102 1.733 0.153 0.204 0.510 0.357 0.561 0.561 0.663 0.306 0.204 0.255 0.255 0.459 0.204 0.102 0.051 0.306 5.148 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 1.017 0.780 0.492 0.394 0.441 0.583 0.689 0.595 0.440 0.689 0.293 0.148 0.488 0.491 0.248 "0.298 8.086 7.5-12.4 12.5-18.4 1.212 1.222 1.260 0.402 0.589 0.717 1.593 1.203 0.747 0.631 0.358 0.273 0.490 0.900 1.035 0.896 13.529 0.084 0.125 0.169 0.000 0.000 0.169 1.034 0.334 0.251 0.167 0.041 0.000 0.042 0.208 0.498 0.333 3.454 1962.000 1747.250 698.170 638.890 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.67 METER LEVEL WIND SPEED MEASURED AT 45.67 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/05/16 E2-71 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 18.5-24.4 0.021 0.040 0.040 0.000 0.000 0.036 0.215 0.074 0.066 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.492 TOTAL TOTAL TOTAL TOTAL

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.018 0.000 0.000 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.020 HOURS HOURS HOURS HOURS TOTAL 2.589 2.422 2.624 1.153 1.744 2.065 4.416 2.563 1.861 1.894 1.203 0.931 1.428 1.854 1.883 1.934 32.563

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<- 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2001 -

MAR 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3:4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.051 0.051 0.051 0.000 0.102 0.000 0.051 0.000 0.357 0.102 0.051 0.102 0.000 0.000 0.102 0.102 0.204 0.357 0.204 0.000 0.000 0.102 0.051 0.051 0.,051 1.478 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 0.243 0.000 0.297 0.096 0.000 0.049 0.437 0.250 0.194 0.145 0.147 0.000 0.048 0.000 0.000 1.048 1.955 7.5-12.4 12.5-18.4 0.271 0.262 0.402 0.092 0.133 0.266 0.770 0.229 0.266 0.181 0.046 0.000 0.000 0.091 0.088 0.178 3.275 0.000 0.084 0.127 0.042 0.000 0.042 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.296 1962.000 1747.250 181.340 145.410 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.67 METER LEVEL WIND SPEED MEASURED AT 45.67 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-72 DATE PRINTED: 2001/05/16 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS TOTAL 0.616 0.398 0.927 0.282 0.184 0.459 1.308 0.683 0.867 0.581 0.245 0.000 0.252 0.142 0.190 0.278 7.411

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2001 -

MAR 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.102 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.051 0.051 0.204 0.000 0.000 0.000 0.000 0.000 0.051 0.102 0.102 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.255 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 0.000 0.000 0.000 0.000 0.000 0.049 0.195 0.098 0.100 0.000 0.000 0.000 0.000 0.000 0.000 0.O00 0.442 7.5-12.4 12.5-18.4 0.000 0.000 0.087 0.087 0.000 0.135 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.400 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1962.000 1747.250 36.280 27.520 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.67 METER LEVEL WIND SPEED MEASURED AT 45.67 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/05/16 V.

E2-73 41 ND I'TRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS TOTAL 0.000 0.000 0.087 0.087 0.051 0.235 0.439 0.200 0.100 0.051 0.000 0.000 0.000 0.000 0.102 0.051 1.403

METEORLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2001 TABLE 19 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (ELEVATED PORTION)

SECOND QUARTER E2-74

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry NP (new sensor)

PART 2 OF 2 ELEVATED RELEASE MODE APR 1,

2001 -

JUN 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 "0.000 0.000 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2122.000 1931.520 17.590 0.000 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor).

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/08/17 E2-75 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry NP (new sensor)

PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2001 -

JUN 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 "0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2122.000 1931.520 11.340 0.000 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/08/17 E2-76 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry NP (new sensor)

PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2001 -

JUN 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.044 0.000 0.000 0.000 "10.000 0.089 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.041 0.000 0.000 0.000 0.000 0.000 0.041 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2122.000 1931.520 14.510 3.750 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/08/17 E2-77 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS TOTAL 0.000 0.000 0.000 0.047 0.000 0.000 0.045 0.000 0.000 0.000 0.041 0.044 0.000 0.000 0.000 0.000 0.177

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry NP (new sensor)

PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2001 -

JUN 30, 2001 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.047 0.236 0.754 0.236 0.660 0.283 0.377 0.283 0.236 0.094 0.094 0.000 3.393 0.377 0.471 0.094 0.283 0.189 0.660 1.131 0.990 0.943 0.707 0.754 0.566 0.518 0.236 0.471 0.094 8.483 0.678 0.407 0.000 0.182 0.228 0.501 1.784 1.000 0.501 0.722 1.090 0.684 0.459 0.501 0.223 "0.316 7.5-12.4 12.5-18.4 18.5-24.4 1.652 1.121 0.123 0.000 0.044 0.546 1.989 1.371 1.389 1.929 1.296 1.379 1.542 0.618 0.490 0.779 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.812 0.077 0.000 0.000 0.000 0.156 0.691 0.465 1.765 1.305 0.076 0.270 0.193 0.770 0.882 0.308 7.770 0.000 0.000 0.000 0.000 0.000 0.000 0.059 0.049 0.410 0.213 0.000 0.000 0.000 0.130 0.161 0.000 1.022 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2122.000 1931.520 1042.420 980.700 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/08/17 E2-78 CALM 0.000 0.000 0.000 0.000 0.0oo 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 9.276 16.267

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.005 TOTAL 3.519 2.123 0.264 0.465 0.507 2.098 6.409 4.110 5.667 5.164 3.593 3.181 2.947 2.348 2.322 1.498 46.216

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry NP (new sensor)

PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2001 -

JUN 30, 2001 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.141 0.047 0.189 0.236 0.047 0.094 0.094 0.471 0.424 0.424 0.283 0.471 0.141 0.000 0.047 0.141 0.094 3.205 0.283 0.424 0.094 0.236 0.189 0.518 0.613 0.801 0.471 0.801 0.613 0.424 0.471 0.141 0.141 0.189 6.409 0.584 0.177 0.138 0.183 0.367 0.902 1.272 1.137 0.772 0.359 0.410 0.091 0.224 0.136 0.135 "0.450 7.5-12.4 12.5-18.4 0.450 0.627 0.251 0.214 0.513 1.837 2.414 1.400 1.729 1.365 0.338 0.206 0.082 0.082 0.450 0.782 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.156 0.039 0.000 0.000 0.000 0.114 0.576 0.929 1.726 0.424 0.000 0.000 0.000 0.039 0.193 0.155 4.350 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2122.000 1931.520 780.430 729.720 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELrA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/08/17 E2-76 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 CALM 7.337 12.740 18.5-24.4 0.025 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.159 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.184

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.022 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.022 TOTAL 1.592 1.455 0.718 0.680 1.163 3.466 5.346 4.691 5.397 3.232 1.832 0.863 0.778 0.446 1.061 1.669 34.388

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry NP (new sensor)

PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2001 -

JUN 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.094 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.189 0.047 0.047 0.047 0.141 0.000 0.000 0.141 0.141 0.094 0.236 0.283 0.047 0.047 0.047 0.047 0.000 1.367 0.047 0.189 0.189 0.047 0.094 0.047 0.094 0.094 0.330 0.236 0.566 0.047 0.000 0.047 0.094 0.047 2.168 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 0.000 0.091 0.319 0.137 0.044 0.183 0.228 0.045 0.141 0.321 0.091 0.000 0.044 0.045 0.000 "0.000 1.690 7.5-12.4 12.5-18.4 0.496 0.856 0.617 0.125 0.252 0.205 0.214 0.000 0.207 0.083 0.000 0.000 0.042 0.000 0.000 0.041 3.138 0.000 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.078 2122.000 1931.520 207.510 183.110 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/08/17 E2-80 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.590 1.183 1.211 0.450 0.391 0.435 0.725 0.280 0.867 0.915 0.986 0.094 0.133 0.139 0.141 0.088 8.629

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry NP (new sensor)

PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2001 -

JUN 30, 2001 CALI 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.047 0.047 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.047 0.000 0.330 0.000 0.094 0.094 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.330 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 0.000 0.091 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 "0.000 0.230 7.5-12.4 12.5-18.4 0.119 0.202 0.124 0.042 0.000 0.041 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.529 0.078 0.078 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.196 2122.000 1931.520 48.200 34.240 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/08/17 E2-81 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS TOTAL 0.245 0.513 0.305 0.089 0.000 0.041 0.092 0.094 0.000 0.093 0.047 0.047 0.000 0.000 0.047 0.000 1.614

METEORLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2001 TABLE 20 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (ELEVATED PORTION)

THIRD QUARTER E2-82

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry NP (new sensor)

PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2001 -

SEP 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 "10.000 0.000 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2142.000 2016.030 18.250 0.000 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/12/18 E2-83 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry NP (new sensor)

PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2001 -

SEP 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 "0.000 0.000 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2142.000 2016.030 9.600 1.000 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-84 DATE PRINTED: 2001/12/18 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NOW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry NP (new sensor)

PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2001 -

SEP 30, 2001 lot CALH 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.093 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.280 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 0.000 0.000 0.000 0.000 0.000 0.000 0.319 0.043 0.000 0.044 0.045 0.133 0.000 0.000 0.000 "0.000 0.584 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.043 0.000 0.000 0.000 0.000 0.000 0.043 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2142.000 2016.030 26.470 19.430 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/12/18 40 E2-85 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.412 0.137 0.047 0.044 0.134 0.133 0.000 0.000 0.000 0.000 0.907

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry NP (new sensor)

PART 2 OF 2 ELEVATED RELEASE MODE JUL 1,

2001 -

SEP 30, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.280 0.187 0.140 0.047 0.187 0.140 1.074 0.747 1.074 0.934 1.074 0.560 0.373 0.140 0.093 0.233 0.187 0.327 0.187 0.373 0.187 0.560 1.867 1.727 2.101 1.494 1.821

1. 167 0.840 0.467 0.280 0.093 0.357 0.719 0.090 0.135 0.137 0.453 0.957 1.451 1.885 1.630 0.946 0.857 0.674 0.356 0.405 "0.808 7.5-12.4 12.5-18.4 18.5-24.4 1.883 1.222 0.122 0.125 0.363 1.108 1.179 1.993 2.503 1.363 0.212 0.461 0.621 0.826 0.248 0.742 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.500 0.498 0.039 0.000 0.039 0.193 0.570 1.374 0.871 0.114 0.039 0.000 0.077 0.076 0.039 0.305 4.733 0.024 0.000 0.000 0.000 0.000 0.000 0.000 0.070 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.035 0.128 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2142.000 2016.030 1172.280 1130.820 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/12/18 E2-86 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 CALM 7.283 13.679 11.857 14.972

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 3.230 2.953 0.577 0.681 0.912 2.500 5.694 7.363 8.480 5.535 4.091 3.045 2.586 1.865 1.065 2.216 52.793

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry NP (new sensor)

PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2001 -

SEP 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.047 0.047 0.047 0.047 0.000 0.000 0.093 0.047 0.093 0.047 0.000 0.047 0.047 0.047 0.047 0.047 0.700 0.140 0.093 0.280 0.233 0.373 0.467 0.373 0.654 0.700 0.747 0.747 0.514 0.093 0.047 0.047 0.280 5.789 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 0.514 0.280 0.233 0.560 0.514 1.027 0.887 0.840 1.120 1.027 0.327 0.747 0.467 0.280 0.327 0.420 9.570 0.713 0.445 0.275 0.182 0.494 1.717 0.986 0.635 0.631 0.359 0.269 0.092 0.270 0.093 0.267 "0.264 7.692 7.5-12.4 12.5-18.4 1.013 1.184 0.947 0.208 0.382 1.413 0.369 0.285 0.495 0.079 0.043 0.126 0.248 0.125 0.041 0.620 7.579 0.193 0.347 0.039 0.039 0.000 0.000 0.077 0.077 0.000 0.000 0.000 0.000 0.000 0.037 0.039 0.115 0.962 2142.000 2016.030 719.440 692.130 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/12/18 E2-87 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.019 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.019

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS TOTAL 2.639 2.396 1.821 1.268 1.763 4.624 2.786 2.538 3.040 2.259 1.387 1.526 1.125 0.629 0.766 1.746 32.312

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/1O0 M)

Browns Ferry NP (new sensor)

PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2001 -

SEP 30, 2001 or CALM 0.000 0.000 0.000 0.000 0.000 o0ooo 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.093 0.093 0.000 0.000 0.093 0.093 0.047 0.187 0.000 0.000 0.093 0.000 0.000 0.000 0.700 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 0.047 0.327 0.140 0.093 0.047 0.047 0.047 0.000 0.093 0.093 0.093 0.047 0.000 0.000 0.000 0.000 1.074 0.179 0.183 0.178 0.180 0.269 0.181 0.047 0.000 0.184 0.179 0.000 0.047 0.000 0.000 0.000 "0.000 1.626 7.5-12.4 12.5-18.4 18.5-24.4 0.771 0.650 0.403 0.295 0.123 0.293 0.000 0.000 0.040 0.084 0.000 0.000 0.000 0.000 0.040 0.119 2.817 0.039 0.268 0.077 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.384 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2142.000 2016.030 157.000 142.390 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/12/18 E2-88 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS TOTAL 1.035 1.428 0.892 0.661 0.439 0.521 0.187 0.093 0.410 0.543 0.093 0.093 0.093 0.000 0.040 0.119 6.648

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry NP (new sensor)

PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2001 -

SEP 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.093 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.140 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 0.000 0.044 0.089 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 "0.045 0.177 7.5-12.4 12.5-18.4 0.080 0.204 0.085 0.203 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.572 0.039 0.344 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.383 2142.000 2016.030 38.960 30.260 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/12/18 E2-89 WI ND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.259 0.592 0.267 0.250 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 1.413

METEORLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2001 TABLE 21 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (ELEVATED PORTION)

FOURTH QUARTER E2-90

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-L.9 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2001 -

DEC 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000, 0.000 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 "0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2150.000 1861.910 21.380 0.000 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2002/02/12

'(

E2-91 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 i 'ý,

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-I.7 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2001 -

DEC 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 "10.000 0.000 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2150.000 1861.910 11.270 0.000 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2002/02/12 E2-92 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1,

2001 -

DEC 31, 2001 CALM 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

  • 0.000 0.046 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.084 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.084 0.000 0.000 0.000 0.000 0.000 0.038 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.038 2150.000 1861.910 13.950 5.590 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2002/02/12 E2-93 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=2 4. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS TOTAL 0.000 0.000 0.000 0.000 0.000 0.121 0.139 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.260

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION-FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE SOCT 1, 2001 -

DEC 31, 2001 14 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.047 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.233 0.047 0.047 0.047 0.186 0.047 0.047 0.419 0.093 0.326 0.372 0.186 0.279 0.047 0.093 0.233 0.047 2.512 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 0.372 0.140 0.140 0.233 0.279 0.372 0.372 0.233 0.372 0.465 0.326 0.326 0.279 0.419 0.419 0.093 4.837 0.635 0.803 0.180 0.137 0.135 0.359 0.316 0.227 0.134 0.361 0.402 0.314 0.496 0.311 0.353 "0.312 5.475 7.5-12.4 12.5-18.4 1.412 1.020 0.568 0.165 0.082 0.850 0.729 0.527 0.889 1.019 0.285 0.780 0.887 0.977 0.604 0.618 11.410 1.481 0.761 0.077 0.076 0.038 0.380 0.864 1.135 1.171 0.644 0.229 0.267 0.303 0.493 1.315 0.605 9.838 2150.000 1861.910 880.320 798.930 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2002/02/12 E2-94 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.717 0.873 0.303 0.029 0.037 0.000 0.060 0.331 0.372 0.035 2.758 TOTAL TOTAL TOTAL TOTAL

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.028 0.004 0.000 0.000 0.008 0.000 0.008 0.000 0.000 0.098 HOURS HOURS HOURS HOURS TOTAL 3.946 2.770 1.011 0.796 0.580 2.053 3.467 3.162 3.245 2.890 1.558 1.973 2.072 2.632 3.294 1.709 37.160

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2001 -

DEC 31, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.047 0.047 0.000 0.093 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.279 0.047 0.140 0.093 0.000 0.000 0.093 0.233 0.140 0.326 0.233 0.093 0.186 0.047 0.140 0.140 0.047 1.953 0.047 0.186 0.465 0.279 0.140 0.512 0.465 0.512 0.372 0.326 0.140 0.372 0.279 0.000 0.233 0.140 4.465 0.312 0.631 0.227 0.270 0.092 0.224 0.529 0.777 0.360 0.179 0.000 0.267 0.180 0.226

"*0.090 "0. 130 7.5-12.4 12.5-18.4 1.350 1.171 0.371 0.041 0.167 1.086 1.335 1.291 1.330 0.491 0.082 0.000 0.165 0.204 0.487 1.304 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.534 0.380 0.000 0.000 0.000 0.723 1.285 0.945 0.800 0.380 0.037 0.000 0.000 0.039 0.414 0.267 5.804 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS ELEVATED RELEASES STABILITY CLASS E ELEVATED STABILITY CLASS E 2150.000 1861.910 723.250 628.240 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2002/02/12 ko E2-95 4.494 10.875 CALM" 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.487 0.649 0.152 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.288

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.061 TOTAL 2.336 2.554 1.156 0.683 0.398 2.638 4.333 4.363 3.398 1.608 0.399 0.826 0.671 0.608 1.364 1.887 29.220 I ".

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2001 -

DEC 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.047 0.000 0.047 0.047 0.000 0.000 0.000 0.233 0.093 0.093 0.140 0.047 0.186 0.140 0.093 0.047 0.093 0.047 0.093 0.140 0.093 0.000 0.093 0.000 1.395 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 0.093 0.093 0.233 0.186 0.186 0.372 0.419 0.186 0.233 0.326 0.047 0.093 0.093 0.000 0.093 0.093 2.744 0.089 0.312 0.090 0.135 0.046 0.354 0.360 0.179 0.181 0.044 0.185 0.136 0.044 0.091 0.090 0.044 2.380 7.5-12.4 12.5-18.4 18.5-24.4 0.564 0.611 0.561 0.321 0.161 0.280 1.143 0.579 0.495 0.041 0.000 0.000 0.042 0.000 0.127 0.202 5.128 0.114 0.077 0.077 0.077 0.000 0.000 0.077 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.461 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2150.000 1861.910 314.860 265.350 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY -

12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2002/02/12 i*

E2-96 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL

>-24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS TOTAL 0.953 1.186

1. 100 0.766 0.626 1.147 2.092 1.037 1.002 0.504 0.324 0.415 0.319 0.091 0.404 0.378 12.342

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2001 -

DEC 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.000 0.000 0.093 0.000 0.140 0.047 0.372 0.186 0.093 0.000 0.093 0.000 0.047 0.093 0.000 0.000 1.163 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 0.186 0.047 0.047 0.000 0.140 0.186 0.744 0.140 0.047 0.047 0.047 0.000 0.093 0.000 0.047 0.000 1.767 0.226 0.000 0.000 0.091 0.182 0.353 0.984 0.093 0.000 0.087 0.000 0.000 0.000 0.133 0.000

"*0.045 2.195 7.5-12.4 12.5-18.4 18.5-24.4 0.609 0.401 0.201 0.160 0.085 0.417 0.166 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.040 0.039 0.191 0.000 0.038 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.268 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2150.000 1861.910 184.970 163.800 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2002/02/12 E2-97 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS TOTAL 1.060 0.639 0.340 0.336 0.547 1.003 2.266 0.465 0.233 0.134 0.140 0.000 0.140 0.226 0.047 0.045 7.619

METEORLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2001 TABLE 22 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES FIRST QUARTER E2-98

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2001 -

MAR 31, 2001 ft CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 92.63 METER LEVEL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2121 0 0

2102 0

DATE PRINTED: 2001/05/16 MEAN WIND SPEED =

0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-99 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2001 -

MAR 31, 2001 CALi 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW

'iUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS B OF VALID WIND DIRECTIOiN-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 92.63 METER LEVEL DATE PRINTED: 2001/05/16 MEAN WIND SPEED =

0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-1 00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL TOTAL 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS HOURS TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2121 0

0 2102 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2001 -

MAR 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS HOURS WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.048 2121 2

2 2102 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 92.63 METER LEVEL

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.095 c

DATE PRINTED: 2001/05/16 MEAN WIND SPEED = 17.75 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-101 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL TOTAL

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2001 -

MAR 31, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.048 0.048 0.000 0.048 0.000 0.000 0.000 0.000 0.190 0.238 0.095 0.048 0.190 0.000 0.095 0.238 0.143 0.095 0.095 0.285 0.238 0.238 0.143 0.143 0.095 2.379 0.238 0.190 0.095 0.333 0.190 0.476 0.333 0.285 0.238 0.048 0.000 0.285 0.285 0.761 0.190 0.238 4.186 0.618 0.476 0.285 0.523 0.238 0.381 0.333 0.143 0.048 0.000 0.143 0.190 0.333 0.476 0.238 0.095 7.5-12.4 12.5-18.4 2.188 3.283 1.142 0.285 0.714 1.189 0.618 0.285 0.523 0.523 0.476 0.285 1.332 2.284 1.332 1.522 2.474 1.713 0.618 0.143 0.048 0.714 0.381 0.476 0.761 0.571 0.238 0.333 0.856 1.284 4.186 2.997 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.476 0.428 0.000 0.000 0.000 0.143 0.381 0.190 0.143 0.428 0.190 0.190 0.523 0.666 1.332 0.523 5.614

>=24.5 0.048 0.000 0.000 0.000 0.000 0.000 0.095 0.143 0.143 0.238 0.000 0.000 0.095 0.095 0.285 0.048 TOTAL 6.280 6.185 2.188 1.522 1.189 2.997 2.379 1.665 1.998 1.951 1.332 1.570 3.663 5.709 7.707 5.519 HOURS OF VALID STABILITY OBSERVATIONS HOURS OF STABILITY CLASS D HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 92.63 METER LEVEL MEAN WIND SPEED = 12.19 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/05/16 E2-102 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 4.520 17.983 17.793 TOTAL TOTAL TOTAL TOTAL TOTAL 1.189 53.853 2121 1150 1132 2102 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2001 -

MAR 31, 2001.

WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.048 0.095 0.000 0.048 0.000 0.095 0.000 0.095 0.333 0.048 0.000 0.048 0.048 0.000 0.095 0.048 0.999 0.095 0.048 0.095 0.238 0.333 0.143 0.095 0.238 0.048 0.143 0.000 0.095 0.095 0.048 0.048 0.048 1.808 0.095 0.143 0.285 0.190 0.381 0.428 0.238 0.095 0.190 0.095 0.143 0.095 0.048 0.048 0.095 0.190 7.5-12.4 12.5-18.4 0.999 1.380 1.094 0.809 0.381 1.237 0.618 1.189 0.856 0.714 0.666 0.571 0.618 0.714 0.523 0.856 WIND PIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.951 1.047 1.094 0.333 0.238 0.428 1.522 1.760 0.761 0.856 0.714 0.381 0.428 0.714 0.666 0.999 12.892 OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 92.63 METER LEVEL MEAN WIND SPEED = 13.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/05/16 E2-10 3

'*1 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.759 13.225 18.5-24.4 0.000 0.095 0.190 0.000 0.048 0.048 0.809 0.856 0.143 0.571 0.143 0.143 0.000 0.048 0.285 0.238 3.616

>=24.5 0.143 0.000 0.048 0.000 0.000 0.048 0.476 0.523 0.190 0.000 0.190 0.000 0.000 0.048 0.000 0.048 1.713 TOTAL TOTAL TOTAL TOTAL TOTAL TOTAL 2.426 2.807 2.807 1.618 1.380 2.426 3.758 4.757 2.521 2.426 1.855 1.332 1.237 1.618 1.713 2.426 37.108 HOURS HOURS HOURS HOURS HOURS 2121 781 780 2102 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY STABILITY CLASS F WIND DIRECTION FOR

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2001 -

MAR 31, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.048 0.048 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.285 0.000 0.000 0.095 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.238 0.000 0.000 0.048 0.095 0.143 0.048 0.048 0.000 0.095 0.000 0.048 0.048 0.000 0.000 0.048 0.000 0.618 0.238 0.143 0.048 0.095 0.143 0.095 0.095 0.571 0.714 0.381 0.285 0.143 0.190 0.095 0.048 0.000 3.283 0.143 0.238 0.285 0.190 0.095 0.143 0.190 0.095 0.428 0.238 0.285, 0.000 0.000 0.000 0.048 0.238 2.617 HOURS OF VALID STABILITY OBSERVATIONS HOURS OF STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2121 159 159 2102 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 92.63 METER LEVEL MEAN WIND SPEED = 12.16 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/05/16 E2-104 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL TOTAL 18.5-24.4 0.000 0.095 0.095 0.143 0.000 0.048 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.428

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 TOTAL 0.381 0.476 0.618 0.523 0.476 0.381 0.428 0.761 1.332 0.618 0.618 0.190 0.190 0.143 0.143 0.285 7.564 HOURS HOURS HOURS

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2001 -

MAR 31, 2001 CAT.M 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.048 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.143 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.048 0.000 0.048 0.000 0.000 0.000 0.048 0.190 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.095 0.333 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.571 OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 0.000 0.000 0.000 0.048 0.143 0.095 0.095 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.428 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2121 29 29 2102 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 92.63 METER LEVEL MEAN WIND SPEED = 10.02 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/05/16 E2-105 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.048 0.048 0.143 0.095 0.190 0.190 0.381 0.095 0.000 0.048 0.000 0.048 0.000 0.095 1.380 TOTAL TOTAL TOTAL HOURS HOURS HOURS

IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2001 TABLE 23 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES SECOND QUARTER E2-106

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry NP (new sensor)

APR 1, 2001 -

JUN 30, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL 2158 0

0 2154 0

DATE PRINTED: 2001/08/17 I..

MEAN WIND SPEED =

0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-107 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry NP (new sensor)

APR 1, 2001 -

JUN 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 OjQO0 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2158 0

0 2154 0

METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2001/08/17 MEAN WIND SPEED =

0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-108 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry NP (new sensor)

APR 1, 2001 -

JUN 30, 2001 CALlt 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 2158 4

4 2154 10 METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2001/08/17 MEAN WIND SPEED =

9.07 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-109 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000' 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.186 TOTAL TOTAL TOTAL HOURS HOURS HOURS

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry NP (new sensor)

APR 1,

2001 -

JUN 30, 2001 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.093 0.093 0.139 0.557 0.325 0.186 0.325 0.418 0.232 0.279 0.139 0.093 0.000 2.925 0.186 0.371 0.093 0.093 0.186 0.325 1.021 1.114 0.511 0.418 0.418 0.371 0.371 0.279 0.511 0.093 6.360 0.604 0.279 0.000 0.325 0.093 0.650 1.346 0.650 0.371 0.418 0.511 0.557 0.418 0.279 0.093 0.279 6.871 7.5-12.4 12.5-18.4 1.811 1.439 0.093 0.046 0.232 1.021 2.321 1.718 1.207 1.346 2.275 1.578 1.532 0.511 0.464 0.557 18.152 1.439 0.279 0.046 0.000 0.000 0.279 0.975 0.743 1.811 2.461 0.696 0.929 0.650 1.021 1.161 0.789 13.278 18.5-24.4 0.046 0.000 0.000 0.000 0.000 0.000 0.279 0.093 0.929 0.836 0.046 0.186 0.046 0.325 0.464 0.371 3.621

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.046 0.139 0.000 0.000 0.000 0.000 0.186 0.093 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW uW NNW SUBTOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2001/08/17 MEAN WIND SPEED = 10.67 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-1 10 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.557 51.764 TOTAL 4.085 2.414 0.232 0.557 0.604 2.414 6.500 4.735 5.060 5.942 4.364 3.853 3.296 2.553 2.971 2.182 TOTAL TOTAL TOTAL TOTAL TOTAL 2158 1116 1115 2154 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry NP (new sensor)

APR 1, 2001 -

JUN 30, 2001 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.093 0.093 0.139 0.093 0.093 0.232 0.139 0.093 0.139 0.046 0.232 0.093 0.093 0.046 0.046 1.671 0.093 0.279 0.093 0.046 0.139 0.093 0.371 0.418 0.464 0.464 0.232 0.093 0.279 0.093 0.093 0.046 3.296 0.139 0.139 0.000 0.093 0.139 0.371 0.743 0.836 0.557 0.186 0.418 0.232 0.279 0.139 0.139 0.186 7.5-12.4 12.5-18.4 18.5-24.4 0.929 0.743 0.371 0.325 0.836 0.929 3.482 1.996 1.439 1.161 1.346 0.279 0.371 0.186 0.279 0.464 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 0.139 0.743 0.325 0.093 0.000 0.046 0.511 1.532 1.486 2.368 1.996 0.232 0.232 0.093 0.046 0.279 0.464 10.446 0.139 0.000 0.000 0.000 0.000 0.046 0.139 0.139 0.789 0.139 0.000 0.000 0.000 0.000 0.139 0.093 1.625

>=24.5 TOTAL 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.232 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.279 2.089 1.578 0.696 0.604 1.253 2.043 6.500 5.014 5.942 4.085 2.321 1.068 1.114 0.557 0.975 1.346 37.187 HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2001/08/17 MEAN WIND SPEED = 10.68 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-111 CALM4P 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 4.596 15.135 TOTAL TOTAL TOTAL TOTAL TOTAL 2158 804 801 2154 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry NP (new sensor)

APR 1, 2001 -

JUN 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.000 0.093 0.093 0.046 0.000 0.093 0.046 0.046 0.000 0.046 0.000 0.000 0.046 0.557 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F 0.046 0.000 0.046 0.046 0.000 0.093 0.046 0.093 0.139 0.093 0.139 0.000 0.186 0.000 0.000 0.093 1-.021 0.000 0.093 0.046 0.093 0.046 0.232 0.139 0.093 0.093 0.186 0.000 0.093 0.093 0.046 0.093 0.046 1.393 7.5-12.4 12.5-18.4 0.046 0.279 0.325 0.232 0.000 0.279 0.371 0.232 0.232 0.186 0.186 0.139 0.093 0.046 0.046 0.000 2.693 OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 0.325 0.650 0.604 0.279 0.000 0.139 0.000 0.000 0.186 0.186 0.557 0.000 0.046 0.000 0.000 0.000 2.971 2158 197 197 2154 0

METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2001/08/17 MEAN WIND SPEED = 10.60 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-112 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW

.3UBTOTAL 18.5-24.4 0.046 0.093 0.232 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.464

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.464 1.114 1.300 0.743 0.139 0.836 0.604 0.418 0.743 0.743 0.929 0.232 0.464 0.093 0.139 0.186 9.146 TOTAL TOTAL TOTAL HOURS HOURS HOURS

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry NP (new sensor)

APR 1, 2001 -

JUN 30, 2001 CALA WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.139 7.5-12.4 12.5-18.4 0.000 0.046 0.093 0.186 0.046 0.046 0.000 0.046 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.557 OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 0.000 0.046 0.371 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.557 2158 37 37 2154 0

METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 13.22 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2001/08/17 E2-113 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.279 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 o0ooo 0.000 0.000 0.000 0.000 0.000 0.325

>-24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.371 0.511 0.232 0.093 0.046 0.000 0.093 0.093 0.046 0.093 0.000 0.046 0.000 0.000 0.093 1.718 TOTAL TOTAL TOTAL HOURS HOURS HOURS

METEORLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2001 TABLE 24 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES THIRD QUARTER E2-114

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry NP (new sensor)

JUL 1, 2001 -

SEP 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0 000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2184 0

0 1996 0

METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2001/12/18 MEAN WIND SPEED =

0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-115 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL HOURS HOURS HOURS

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION Pdh STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry NP (new sensor)

JUL 1, 2001 -

SEP 30, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

-7.4 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL o.oob 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.050 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2184 1

1 1996 0

METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED =

7.40 DATE PRINTED: 2001/12/18 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-116 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 CALN6 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry NP (new sensor)

JUL 1,

2001 -

SEP 30, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.100 0.100 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.251 0.000 0.000 0.000 0.000 0.000 0.100 0.251 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.401 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.050 0.100 0.050 0.000 0.000 0.000 0.000 0.251 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.100 0.351 0.150 0.050 0.050 0.150 0.050 0.000 0.000 0.000 0.000 0.902 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2001/12/18 MEAN WIND SPEED =

6.70 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-117 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL 2184 20 18 1996 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry NP (new sensor)

JUL 1, 2001 -

SEP 30, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.200 0.100 0.050 0.100 0.100 0.501 0.852 0.701 0.651 0.852 0.401 0.551 0.200 0.251 0.100 0.150 0.200 0.251 0.150 0.150 0.150 0.451 1.603 1.303 1.253 0.902 1.102 1.002 1.002 0.251 0.200 0.100 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.100 0.000 0.050 0.000 0.000 0.000 0.251 0.200 0.451 0.150 0.200 0.100 0.551 1.353 0.852 1.052 1.202 0.752 0.601 0.501 0.551 0.301 0.701 9.519 7.5-12.4 12.5-18.4 1.854 1.303 0.200 0.251 0.150 1.253 1.303 1.754 2.655 2.405 1.102 0.802 0.802 1.152 0.351 1.052 1.052 1.152 0.150 0.000 0.401 0.902 1.002 2.555 1.303 0.752 0.100 0.100 0.251 0.150 0.000 0.401 CALt 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.150 0.000 0.000 0.000 0.000 0.050 0.251 0.501 0.401 0.050 0.000 0.000 0.000 0.000 0.000 0.050 1.453

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 3.707 3.257 0.701 0.701 0.902 3.707 6.363 7.665 7.315 6.212 3.557 3.056 2.806 2.355 0.952 2.455 0.000 55.711 "f I TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2001/12/18 MEAN WIND SPEED =

8.64 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-118 5.762 10.070 18.387 10.271 TOTAL TOTAL TOTAL 2184 1235 1112 1996 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry NP (new sensor)

JUL 1, 2001 -

SEP 30, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.050 0.000 0.000 0.000 0.000 0.050 0.100 0.050 0.050 0.050 0.050 0.000 0.000 0.050 0.050 0.050 0.551 0.050 0.050 0.000 0.100 0.100 0.200 0.451 0.301 0.301 0.150 0.200 0.200 0.100 0.100 0.050 0.150 2.505 0.050 0.200 0.251 0.251 0.150 0.301 0.952 0.852 0.551 0.601 0.852 0.251 0.351 0.200 0.251 0.100 6.162 0.301 0.150 0.200 0.150 0.351 0.701 0.952 1.202 0.601 0.401 0.401 0.701 0.451 0.100 0.251 0.301 7.5-12.4 12.5-18.4 18.5-24.4 1.052 0.701 0.601 0.451 0.301 1.202 2.355 0.752 1.002 0.952 0.501 0.401 0.601 0.251 0.251 0.351 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.852 1.303 0.852 0.150 0.100 0.200 0.601 0.301 0.451 0.150 0.000 0.050 0.050 0.050 0.000 0.251 5.361 0.100 0.351 0.100 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.100 0.701 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2001/12/18 10, MEAN WIND SPEED =

8.46 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-119 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 7.214 11.723

>=2 4.5 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 TOTAL 2.505 2.756 2.004 1.102 1.002 2.655 5.411 3.457 2.956 2.305 2.004 1.603 1.553 0.802 0.852 1.303 34.269 TOTAL TOTAL TOTAL 2184 740 684 1996 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry NP (new sensor)

JUL 1, 2001 -

SEP 30, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.100 0.100 0.000 0.000 0.050 0.000 0.050 0.000 0.000 0.301 0.050 0.000 0.000 0.301 0.000 0.050 0.050 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.551 0.100 0.050 0.000 0.000 0.050 0.251 0.100 0.100 0.050 0.000 0.100 0.050 0.000 0.050 0.000 0.000 0.902 7.5-12.4 12.5-18.4 0.150 0.501 0.150 0.351 0.301 0.301 0.251 0.150 0.200 0.251 0.050 0.000 0.000 0.050 0.000 0.050 2.756 0.551 0.401 0.401 0.150 0.050 0.050 0.000 0.000 0.100 0.150 0.050 0.100 0.000 0.000 0.000 0.050 2.054 18.5-24.4 0.050 0.451 0.251 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.802

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.902 1.403 0.802 0.852 0.401 0.651 0.401 0.401 0.451 0.401 0.200 0.200 0.000 0.150 0.050 0.100 7.365 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2001/12/18 MEAN WIND SPEED = 11.47 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-120 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 CALi 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL 2184 154 147 1996 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry NP (new sensor)

JUL 1, 2001 -

SEP 30, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 7.5-12.4 12.5-18.4 18.5-24.4 0.200 0.100 0.150 0.000 0.050 0.100 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.601 OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 0.000 0.050 0.200 0.100 0.150 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.501 0.100 0.401 0.050 0.000 0.000 0.000 0.000 "0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.551 2184 34 34 1996 0

METEOROLOGICAL FACILITY:

Browns Ferry NP (new sensor)

STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2001/12/18 1W MEAN WIND SPEED = 15.04 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-121 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.351 0.551 0.401 0.100 0.200 0.100 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.703 TOTAL TOTAL TOTAL HOURS HOURS HOURS

METEORLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2001 TABLE 25 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES FOURTH QUARTER E2-122

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2001 -

DEC 31, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 o:ooo 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND -89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/02/12 MEAN WIND SPEED =

0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-123 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALN 0.000 0.000 0.000 0.000 0.000

,%00.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL TOTAL 2178 0

0 2174 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2001 -

DEC 31, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY CALM OBSERVATIONS METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 ANI) 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL 2178 0 0

2174 0

DATE PRINTED: 2002/02/12 MEAN WIND SPEED =

0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-124 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CAIA 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL TOTAL

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2001 -

DEC 31, 2001 CAIA 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 2178 6

6 2174 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/02/12 MEAN WIND SPEED =

9.18 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-125 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>-24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.138 0.092 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.276 TOTAL TOTAL TOTAL HOURS HOURS HOURS

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.'5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2001 -

DEC 31, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.046 0.046 0.046 0.138 0.000 0.184 0.414 0.092 0.092 0.368 0.276 0.138 0.230 0.046 0.230 0.184 2.530 0.276 0.184 0.000 0.184 0.322 0.184 0.322 0.184 0.138 0.552 0.138 0.184 0.138 0.368 0.322 0.092 3.588 0.506 0.460 0.138 0.230 0.184 0.322 0.184 0.230 0.092 0.322 0.138 0.276 0.276 0.414 0.322 0.184 7.5-12.4 12.5-18.4 18.5-24.4 1.334 1.334 0.690 0.138 0.092 0.552 0.828 0.460 0.644 0.874 0.552 1.058 0.552 0.874 0.552 0.644 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 2.116 0.874 0.092 0.230 0.046 0.874 0.736 1.058 1.472 1.196 0.368 0.598 0.736 0.874 1.058 0.782 13.109 0.230 0.138 0.000 0.000 0.046 0.230 1.288 1.610 0.644 0.460 0.046 0.092 0.276 0.552 1.150 0.184 6.946 OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 13.15 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2002/02/12 E2-126 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 4.278 11.178

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 1.242 0.828 0.046 0.000 0.000 0.046 0.046 0.276 0.046 0.000 2.530 TOTAL TOTAL TOTAL TOTAL TOTAL TOTAL 4.508 3.036 0.966 0.920 0.736 2.346 5.014 4.462 3.128 3.818 1.518 2.392 2.254 3.404 3.680 2.070 44.250 HOURS HOURS HOURS HOURS HOURS 2178 962 962 2174 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2001 -

DEC 31, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.046 0.046 0.092 0.046 0.046 0.092 0.230 0.092 0.184 0.230 0.092 0.092 0.230 0.046 0.000 0.138 1.702 0.000 0.046 0.276 0.138 0.184 0.230 0.506 0.046 0.046 0.046 0.000 0.092 0.046 0.092 0.138 0.046 1.932

-7.4 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.092 0.092 0.276 0.230 0.276 0.276 0.138 0.092 0.276 0.276 0.046 0.092 0.184 0.046 0.046 2.438 0.828 0.782 0.552 0.368 0.138 0.322 0.644 1.334 1.104 0.690 0.552 0.322 0.368 0.276 0.368 0.644 9.292 1.426 1.334 0.322 0.000 0.046 0.782 2.116 1.794 1.426 1.058 0.460 0.138 0.184 0.184 0.322 0.874 12.466 0.322 0.276 0.046 0.000 0.000 0.276 1.472 1.196 0.598 0.138 0.046 0.000 0.000 0.000 0.460 0.092 4.922

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.184 0.920 0.138 0.046 0.000 0.000 0.000 0.000 0.000 0.000 2.622 2.576 1.380 0.874 0.644 2.024 5.428 5.566 3.588 2.484 1.426 0.690 0.920 0.782 1.334 1.840 0.000 0.000 0.000 0.046 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.138 HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/02/12 MEAN WIND SPEED - 13.29 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-127 CAL1t 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.288 34.177 TOTAL TOTAL TOTAL TOTAL TOTAL 2178 747 743 2174 0

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant OCT 1,

2001 -

DEC 31, 2001 CALM 0.000 0.000 0.000 0.000 0.000 0:000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.138 0.000 0.092 0.000 0.000 0.046 0.046 0.184 0.138 0.046 0.046 0.000 0.000 0.000 0.782 0.046 0.000 0.000 0.092 0.230 0.138 0.276 0.000 0.000 0.138 0.046 0.046 0.092 0.046 0.000 0.046 1.196 0.046 0.046 0.046 0.046 0.046 0.276 0.092 0.092 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.736 7.5-12.4 12.5-18.4 0.092 0.138 0.460 0.276 0.276 0.322 0.506 0.368 0.690 0.230 0.230 0.276 0.092 0.046 0.184 0.046 4.232 OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 11.61 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2002/02/12 E2-128 0.506 0.552 0.828 0.276 0.046 0.322 0.598 0.920 0.736 0.092 0.046 0.046 0.046 0.000 0.138 0.046 5.198 2178 288 288 2174 0

18.5-24.4 0.138 0.230 0.276 0.184 0.000 0.000 0.046 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.092 1.058

>-24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL TOTAL TOTAL 0.874 0.966 1.748 0.874 0.690 1.058 1.518 1.426 1.610 0.644 0.506 0.414 0.276 0.092 0.322 0.230 13.247 HOURS HOURS HOURS HOURS HOURS

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant OCT 1,

2001 -

DEC 31, 2001 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.046 0.092 0.092 0.046 0.138 0.046 0.046 0.000 0.092 0.000 0.000 0.000 0.598 0.000 0.000 0.092 0.092 0.092 0.092 0.230 0.000 0.138 0.138 0.138 0.000 0.000 0.000 0.000 0.000 1.012 0.000 0.000 0.000 0.046 0.000 0.276 0.276 0.046 0.046 0.046 0.000 0.000 0.000 0.000 0.046 0.000 0.782 7.5-12.4 12.5-18.4 0.000 0.184 0.138 0.046 0.046 0.230 0.782 1.104 0.046 0.046 0.046 0.000 0.000 0.092 0.092 0.000 2.852 0.230 0.552 0.414 0.230 0.138 0.092 0.046 0.138 0.000 0.138 0.046 0.000 0.000 0.000 0.092 0.000 2.116 TOTAL HOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2178 175 175 2174 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED -

10.45 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-129 DATE PRINTED: 2002/02/12 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.046 0.552 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.598

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.276 1.288 0.644 0.414 0.322 0.782 1.426 1.334 0.368 0.414 0.276 0.046 0.138 0.092 0.230 0.000 8.050 f

ENCLOSURE 3 TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT (BFN)

UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 2001 E3-1

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2001 Regulatory and BFN ODCM Limits A.

Fission and Activation Gases in Gaseous Effluent:

The release of fission and activation gases is regulated by the dose limits of 10 CFR 50 Appendix I and BFN Offsite Dose Calculation Manual (ODCM). The air dose to areas at and beyond the site boundary due to noble gases released in gaseous effluents per unit, shall be limited during any calendar quarter to < 5 millirad (mrad) for gamma radiation and < 10 mrad for beta radiation; and during any calendar year to < 10 mrad for gamma radiation and < 20 mrad for beta radiation.

B.

lodines and Particulates with Half-Lives Greater than Eight Days in Gaseous Effluents.

The release of iodines and particulates in gaseous effluent is regulated by the dose limits of 10 CFR 50 Appendix I and the BFN ODCM. The dose to a member of the public from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half-lives'greater than eight days in gaseous effluent released per unit to areas at and beyond the site boundary shall be limited to any organ during any calendar quarter to < 7.5 millirem (mrem), and during any calendar year to < 15 mrem.

C.

Liquid Effluents The release of radioactive liquid effluents is regulated by the dose limits of 10 CFR 50 Appendix I and the BFN ODCM. The doses or dose commitment to a member of the public from radioactive materials in liquid effluents released from each unit to unrestricted areas shall be limited during any calendar quarter to < 1.5 mrem to the total body and <5 mrem to any organ and during any calendar year to < 3 mrem to the total body and < 10 mrem to any organ.

II.

Limitation on Dose Rate A.

Fission and Activation Gases in Gaseous Effluent:

1. The instantaneous release rate of fission and activation gases is based on the dose rate limits of 10 CFR 20.1301 and the BFN ODCM. The dose rate at any time to areas at and beyond the site boundary due to noble gases released in gaseous effluents from the site shall be limited to

< 500 mrem per year to the total body and < 3000 mrem per year to the skin.

2. The BFN ODCM Section 7.2 determines the maximum noble gas release rate.

E3-2

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2001

11.

Limitations on Dose Rate (Continued)

B lodines and Particulates with Half-Lives Greater than Eight Days in gaseous effluents

1.

The instantaneous release rate of particulates and iodines is regulated by the dose rate limits of the BFN ODCM. The dose rate at any time to areas at and beyond the site boundary, due to 1-13 1, 1-133, H-3 and particulates with greater than eight days half-lives released in gaseous effluents from the site, shall be limited to < 1500 mrem per year to any organ.

2.

The BFN ODCM Section 7.3 determines the maximum particulate and iodine dose rates.

C.

Liquid Effluents

1. The concentration of radionuclides in liquid effluents released at any time from the site to unrestricted areas shall be limited to the concentrations specified in 10 CFR 20.1001 20.2402, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases.
2. For dissolved or entrained noble gases, the concentration shall be limited to 2E-4 [tCi per milliliter (ml) total activity.

HI1.

Measurements and Approximations of Total Radioactivity A.

Fission and Activation Gases:

1. Noble gases in the building vent and stack (elevated) gaseous effluents are continuously monitored. The flow rate of the stack is continuously monitored and the building vent effluent flow rates are calculated once a shift based on the configuration of operating exhaust fans. The vent flow is calculated for each release. Gas grab samples of the stack are taken and analyzed weekly. Gas grab samples of in-service vents are taken and analyzed monthly. The specific noble gas activity concentrations and total volume of the gases are used to calculate the total curies of noble gases released.
2. The tritium concentration is determined by the analysis of a monthly grab sample for each release point.

E3-3

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2001 mI.

Measurements and Approximations of Total Radioactivity (continued)

B.

lodines and Particulates

1.

Iodines and particulates are continuously sampled on impregnated charcoal filters and particulate filters, respectively. The charcoal and particulate samples are replaced at least weekly and analyzed to determine specific activity concentrations. The specific activity concentrations and vent flow rate data are used weekly to verify that release rate limits were not exceeded. The specific activity concentrations and total volume of gaseous effluent are used on a monthly basis to determine the total curies of each particulate and iodine released during the month.

2.

The gross alpha concentration is determined by analysis of a monthly particulate filter composite sample and strontium -89 and -90 are determined by analysis of a quarterly particulate filter composite sample for each release point.

C.

Liquid Effluents I.

The gamma ray emitting radionuclide concentrations are determined for each batch by gamma ray spectroscopy analysis of a grab sample. The allowable release rate is calculated for each batch based upon the known dilution flow. The flow rate of the liquid effluent is continuously monitored and the total volume released in each batch is determined. The total gamma activity released in each batch is determined by multiplying the radionuclide concentrations by the total volume discharged. The total gamma activity released during the month is then determined by summing the gamma activity content of each batch discharged during the month.

2.

The gross alpha and tritium concentrations are measured on a monthly composite sample.

The strontium -89 and -90 and iron -55 are measured on a quarterly composite sample.

D.

The Radioactive Gaseous and Liquid Waste Monitoring Sampling and Analysis Program is specified in ODCM Sections 1/2.2.1 and 1/2.2.2.

E3-4

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SUPPLEMENTAL INFORMATION 2001 IV.

Batch A. Liquid Units Number of batches released Each Total time for batches released Minutes Maximum time period for a batch release Minutes Average time period for a batch release Minutes Minimum time period for a batch release Minutes Average stream flow duringperiod of release into a flowing stream Cubic feet per second Quarter I

0 0

0 0

0 Quarte Quarte Quarter 2

3 4

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 B. Gaseous None C. Abnormal/Unplanned Releases*

Type Liquid Gaseous Number of Releases None None Total Activity Releases (Curies)

None None

  • An explanation of any liquid or gaseous abnormal/unexplained release shall be documented in the summary.

E3-5

1.
2.
3.
4.
5.

6.

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES YEAR 2001 Units Quarter Quarter Quarter A. Fission and Activation Products 1

2 3

(Does not include tritium, gases, Alpha)

1. Total Release Curies NR*

NR NR

2. Average Diluted Concentration Released During Period

[tCi/ml NR NR NR

3.

Percent of Applicable Limit B. Tritium

1. Total Releases Curies NR NR NR
2. Average Diluted Concentration Released During Period

ýICi/ml NR NR NR

3.

Percent of Applicable Limit C. Dissolved and Entrained Noble Gases

1. Total Releases Curies NR NR NR
2. Average Diluted Concentration Released During Period ItCi/ml NR NR NR
3.

Percent of Applicable Limit D. Gross Alpha Radioactivity

1. Total Releases Curies NR NR NR
2. Average Diluted Concentration Released During Period

[tCi/ml NR NR NR E. Volume of Liquid Waste to Discharge Canal (Prior to dilution)

Liters NR NR NR F. Volume of Dilution Water for Period Liters NR NR NR G. Total CCW gigagallons NR NR NR

  • NR -- No liquid releases were made in the 1st 2 nd 3rd and 4 h quarters.
    • The applicable limit is expressed in terms of dose. See Enclosure 1, Tables 5 through 8 Quarter Error 4

9 NR NR NR NR NR 6

8 NR NR 48 NR 3

10 NR NR NR E3-6

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT LIQUID RELEASES FOR YEAR 2001 - BATCH MODE CURIES Isotope Ouarter Quarter Quarter Quarter (Required by Regulatory 1

2 3

4 (REG) Guide 1.21)

1.

Ba-140 NR*

NR NR NR

2.

Ce-141 NR NR NR NR

3.

Co-58 NR NR NR NR

4.

Co-60 NR NR NR NR

5.

Cr-51 NR NR NR NR

6.

Cs-134 NR NR NR NR

7.

Cs-137 NR NR NR NR

8.

Fe-59 NR NR NR NR

9.

1-131 NR NR NR NR

10.

La-140 NR NR NR NR

11.

Mn-54 NR NR NR NR

12.

Mo-99 NR NR NR NR

13.

Nb-95 NR NR NR NR

14.

Sr-89 NR NR NR NR

15.

Sr-90 NR NR NR NR

16.

Tc-99m NR NR NR NR

17.

Xe-133 NR NR NR NR

18.

Xe-135 NR NR NR NR

19.

Zn-65 NR NR NR NR

20.

Zr-95 NR NR NR NR Others (Nc4 Required by REG Guide 1.21)

NONE

  • NR -- No liquid releases were made during the 1st 2nd 3rd and 4th quarters.

E3-7

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES YEAR 2001 Units Quarter Quarter Quarter 1

2 3

Quarter Error 4

A. Fission and Activation Gases

1. Total Releases Ci 2.97E+02 2.40E+02 3.37E+01 1 36E+01 45
2. Average Release Rate for Period [tCi/sec 3.82E+01 3.05E+01 4.24E+00 1.71E+00
3. Percent of Applicable limit B. Iodines
1. Total Iodine-131 Ci 4.77E-03 5.41E-03 5.40E-03 3.89E-03 36
2. Average Release Rate for Period htCi/sec 6.14E-04 6.88E-04 6.79E-04 4.89E-04
3. Percent of Applicable Limit C. Particulates
1. Particulates with half-lives

> eight days Ci 4.42E-03 2 90E-03 9 89E-04 1.02E-03 35

2. Average release rate for period

.Ci/sec 5.69E-04 3.69E-04 1.24E-04 1.29E-04

3. Percent of Applicable limit
4. Gross alpha radioactivity Ci ND**

ND ND ND D.Tritium

1. Total release Ci 1.95E+01 9.22E+00 1.48E+01 1.53E+01 21
2. Average release rate for period [tCi/sec 2 51E+00 1.17E+00 1.86E+00 1.92E+1
3. Percent of Applicable Limit
  • Applicable Limits are expressed in terms of dose. See Enclosure 1, Tables 1 through 4.
    • ND --tNot Detected.

E3-8 1'

00

EF]

(

CURIES

1. Fission Gases Kr-85m Kr-85 Kr-87 Kr-88 Xe-133 Xe-135m Xe-135 Xe-138 Others (specify)

NONE Total for Period

2.

lodines 1-131 1-133 Total for Period

  • ND - Not Detected.

FLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2001 3ASEOUS EFFLUENTS - ELEVATED RELEASE Quarter Quarter Quarter 1

2 3

7.99E+01 ND*

2.97E+00 1.52E+02 6.21E+01 ND ND ND 8 64E+01 ND 1.19E+00 1.16E+02 3.56E+01 ND ND ND 3.3 7E+01 ND ND ND ND ND ND ND 2.97E+02 2.40E+02 3.37E+01 3.41E-04 6.34E-04 9 75E-04 3.87E-04 6.93E-04 1.08E-03 4.03E-04 7.04E-04 1.11E-03

  • uarter 4

1.36E+01 ND ND ND ND ND ND ND 1.36E+01 2.32E-04 3.28E-04 5 61E-04 E3-9

CURIES

3.

Particulates*

Sr-89 Sr-90 Cs-134 Cs-137 Ba-140 La-140 Others (specify)

Rb-88 Rb-89 Sr-91 Y-91m Ru-103 Te-132 Cs-138 Ba-139 Ce-144 Au-199 Total for Period*

4.

Tritium EFFLUENT AND WASTE DISPOSAL ANNUAL REPORI YEAR 2001 GASEOUS EFFLUENTS - ELEVATED RELEASE Quarter Quarter Quarter 1

2 3

8.79E-05 ND**

ND ND 1.1 6E-04 6.04E-05 11 3.59E-02 2.87E-02 9.58E-04 8.57E-04 ND ND 1.28E-01 8.48E-02 2.20E-06 5.44E-06 2.80E-01 4.39E-01 6.53E-05 ND ND ND 1.15E-04 6.44E-05 6.73E-02 9.30E-02 4.42E-04 8.04E-04 ND ND 1.53E-01 7.97E-02 ND 2.09E-05 3.94E-01 5.68E-01 7.14E-05 ND ND ND 9.15E-05 5.52E-05 4.32E-02 1.04E-01 8.96E-04 8.56E-04 ND 1.47E-06 2.17E-01 1.18E-01 ND 6.45E-05 4 85E-01 2.02E+00

  • Includes all nuclides, even those with less than an eight day half-life.
    • ND - Not Detected.

E3-10 Quarter 4

8.01E-05 ND ND ND 1.34E-04 7.21E-05 1.94E-02 2.28E-01 9.62E-04 8.12E-04 3.90E-06 3.80E-06 2.40E-01 1.11E-01 ND 4.74E-05 6 OIE-01 8.83E-01

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2001 GASEOUS EFFLUENTS - GROUND RELEASE CURIES Quarter Quarter Quarter Quarter 1

2 3

4

1. Fission Gases Kr-85m ND*

ND ND ND Kr-85 ND ND ND ND Kr-87 ND ND ND ND Kr-88 ND ND ND ND Xe-133 ND ND ND ND Xe-135m ND ND ND ND Xe-135 ND ND ND ND Xe-138 ND ND ND ND Others(specify)

NONE Total for Period ND ND ND ND

2.

Iodines 1-131 2.15E-03 1.75E-03 1.58E-03 1.77E-03 1-133 1.07E-02 6.48E-03 5.65E-03 5.71 E-03 1-135 3.67E-04 ND ND ND Total for Period 1.33E-02 8 23E-03 7.23E-03 7 47E-03

  • ND - Not Petected.

E3-11

CURIES

3. Particulates*

Sr-89 Sr-90 Cs-134 Cs-137 Ba-140 La-140 Others (specify)

Rb-89 Sr-91 Y-91m Cs-138 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2001 GASEOUS EFFLUENTS - GROUND RELEASE Quarter Quarte Quarte 1

2 3

1.22E-04 2.51E-05 2 33E-'

ND*

ND ND ND ND ND ND ND ND 5.79E-05 5.72E-06 4.29E-(

1.34E-05 3.98E-06 3.57E-(

4.61E-03 4.74E-04 2.97E-03 6.281E-02 3.15E-02 Ba-139 ND 1.53E-04 6 10E-04 7.68E-03 2.OOE-02 Total for Period*

1.03E-01 2 84E-02

4.

Tritium 4.23E+00 7.09E-01

  • Include all nuclides even those with less than an eight day half-life.
    • ND - Not Detected.

r 05

  • 5 36 5.98E-03 3.73E-04 8.18E-04 1.21E-02 1.92E-02 3 85E-02 2.8 1E+00 E3-12 Quarter 4

5.58E-05 ND ND ND 1.20E-04 5.00E-05 ND 9.87E-04 2 67E-03 2.355E-02 3.97E-02 6.70E-02 3.50E+00

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2001 GASEOUS EFFLUENTS - MIXED MODE RELEASE*

CURIES Quarter Quarter Quarter Quarter 1

2 3

4

1.

Fission Gases Kr-85m ND**

ND ND ND Kr-85 ND ND ND ND Kr-87 ND ND ND ND Kr-88 ND ND ND ND Xe-133 ND ND ND ND Xe-135m ND ND ND ND Xe-135 ND ND ND ND Xe-138 ND ND ND ND Others(specify)

NONE Total for Period ND ND ND ND

2.

Iodines 1-131 2.28E-03 3.27E-03 3.41E-03 1.89E-03 1-132 1.33E-04 ND ND ND 1-133 1.07E-02 1.25E-02 1.21E-02 6.78E-03 1-135 9.18E-04 3.29E-04 ND ND Total for P4riod 1.40E-02 1.61E-02 1.55E-02 8 67E-03

  • The Reactor Building and Radwaste Building are treated as split-level releases.
    • ND - Not Detected.

E3-13

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2001 GASEOUS EFFLUENTS - MIXED MODE RELEASE*

CURIES

3.

Particulates**

Sr-89 Sr-90 Cs-134 Quarter 1

1.85E-04 ND ND 2.42E-05 7.3 1E-04 4.54E-04 Cs-137 Ba-140 La-140 Quarter 2

1.39E-04 ND ND 3.58E-05 7.3 5E-04 4.64E-04 Quarter 3

7.51E-05 ND 1.64E-06 6.47E-05 5.68E-04 3.78E-04 Quarter 4

9.90E-05 ND 4.55E-06 5.93E-05 4.25E-04 2.74E-04 Others (specify)

Na-24 Cr-51 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Zn-69m Y-91m Sr-91 Y-92 Sr-92 2.09E-05 1.10E-04 2.22E-04 1.16E-05 ND 2.65E-03 ND 5.32E-05 7.78E-03 1.28E-02 3.95E-05 3.23E-04 4

7.50E-05 3.17E-04 1.37E-04 3.56E-05 1.81E-05 1.17E-03 2.15E-05 ND 7.3 1E-03 1.31E-02 1.1 OE-05 2.69E-04 ND ND ND ND ND ND ND ND 6.05E-03 6 22E-03 ND 1.61E-03 ND ND 6.30E-06 ND ND 6.56E-06 ND ND 5.18E-03 7.84E-03 ND 1.43E-03

  • The Reactor Building and Radwaste Building are treated as split-level releases.

"**Includes all nuclides, even those with less than an eight day half-life.

      • ND - Not Detected.

E3-14

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2001 GASEOUS EFFLUENTS - MIXED MODE RELEASE*

CURIES Quarter Quarter Quarter Quarter Particulates** (Continued) 1 2

3 4

Others (specify)

Nb-97 ND***

ND ND 1.93E-05 Mo-99 1.81E-04 1.05E-04 ND ND Tc-99m 1.81E-04 4.22E-05 ND ND Ag-1I0m 7.52E-05 6.71E-05 4.20E-05 2.79E-05 Cs-138 1.07E-02 1.22E-02 ND ND Ba-139 2.29E-01 1.32E-01 1.72E-01 1.46E-01 Ce-141 2.98E-05 1.20E-05 8.84E-06 ND Total for Period**

2 65E-01 1.68E-01 1.87E-01 1.61E-01

4.

Tritium 1.49E+01 7.95E+00 9.99E+00 1.09E+01

  • The Reactor Building and Radwaste Building are treated as split-level releases.

"**Includes all nuclides, even those with less than an eight day half-life.

      • ND - Not Detected.

E3-15

BROWNS FERRY NUCLEAR PLANT ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT 2001 SOLID WASTE AND IRRADIATED FUEL A.

Solid Waste Shipped Off-site for Burial or Disposal (Not Irradiated Fuel)

I Tvye of Waste Units Amount Error %

a.

Spent resins, filter sludge m3 0.OOE+00 evaporator bottoms, etc.

Ci O.OOE+00

b.

Dry compressible waste, contaminated m3 1.77E+02 equipment, etc.

Ci 7.28E+01

+/-25.0

c.

Irradiated components, control rod m3 0.OOE+00 drives Ci 0.OOE+00

d.

Cartridge filters m3 0.OOE+00 Ci 0.OOE+00

2. Estimate of Major Nuclide Composition by Waste Type
a.

Dry compressible waste, contaminated equipment, etc.

Nuclide Percentae

1. Iron55 (1) 5.09E+01
2.

Cobalt6 0 (1) 1.71E+01

3.

Cesium 137 (1) 1.15E+01 4

Zinc65 (1) 5.59E+00

5. Nickel 63 (1) 5.14E+00
6.

Cesium134 (1) 4.39E+00

7. Silver 110m (1) 2.89E+00
8. Manganese 54 (1) 2.16E+00
9.

Chromium51 (1) 2.01E-01

10. Cobalt5 8 (1) 4.01E-02
11. Strontium89 (1) 1.00E-02
12. Iron5 9 (1) 1.15E-04
13.
14.
15.
16.
17.

18.

Antimony 12 5 95 Zirconium Cerium144 Antimony Cobalt 57 6ther (1)

(1)

(1)

(1)

(1)

(1) 4.99E-05 3.99E-05 2.OOE-05 9.99E-06 4.99E-06

<2.OOE-02 Activity (Curies) 3.71 E+O1 1.25E+01 8 40E+00 4.07E+00 3.74E+00 3.20E+00 2.11E+00 1.57E+00 1.46E-01 2.92E-02 7.28E-03 8.36E-05 3.64E-05 2 91E-05 1.45E-05 7.27E-06 3.64E-06

<1.46E-02 (1) Calculated E3-16

BROWNS FERRY NUCLEAR PLANT ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT 2001 SOLID WASTE AND IRRADIATED FUEL

3. Solid Waste Disposition Number of Shipments 32 6

Mode of Transportation (30) Sole Use Truck (2) Non Sole Use Truck (5) Sole Use Truck (1) Non Sole Use Truck Destination US Ecology Oak Ridge, TN Duratek Oak Ridge, TN B.

Irradiated Fuel Disposition Number of Shipments None Mode of Transportation N/A Destination N/A C.

Description of Shipments Number of Shipments 38 Type Container Strong Tight Container Solidification Agents Used:

Absorbents Used:

Type Quantity A-LSA 1I LTD QTY Number of Containers 43 Container Volume See Note Waste TyAe DAW None None NOTE: The 38 shipments of waste packaged in strong tight containers consisted of the following:

Type of STC 40' "Sealand" 20' "Sealand" LSA Metal Boxes Number of Packages 30 12 1

Volume of Packages (m3) 2.31E+03 4.36E+02 5.81E+00 E3-17

BROWNS FERRY NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT

SUMMARY

OF ABNORMAL/UNPLANNED RELEASES 2001 The release of radioactive material to the environment from Browns Ferry has been a small fraction of the 10 CFR 20 Appendix B and 10 CFR 50 Appendix I limits. There were no limits exceeded as specified in 10 CFR 20 Appendix B and 10 CFR 50 Appendix I.

No abnormal gaseous or liquid releases occurred in 2001.

During the reporting period, January 1 through December 31, 2001, there was no missed compensatory measures.

E3-18

ENCLOSURE4 TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT (BFN)

UNITS 1, 2, AND 3 INOPERABLE RADIOLOGICAL EFFLUENT INSTRUMENTATION REPORT 2001 E4-1

INOPERABLE RADIOLOGICAL EFFLUENT INSTRUMENTATION REPORT 2001 This report is to comply with Browns Ferry Nuclear Plant Offsite Dose Calculation Manual (Offsite Dose Calculation Manual (ODCM)) Sections 1/2.1.1 and 1/2.1.2. The ODCM requires the exertion of best efforts to return inoperable instruments to operable status within 30 days. Failure to return such instruments to an operable status within the prescribed interval requires a description in the Annual Radioactive Effluent Release Report.

During the reporting period, January I through December 31, 2001, there were no radioactive liquid or gaseous effluent monitoring instrumentation out of service for greater than 30 days.

Some effluent monitors and flow instrumentation were placed in "out-of-service" status because these monitors' effluent streams were isolated. Therefore, these monitors are not included in this report.

4 E4-2