Emergency Plan Implementing Procedures Manual Volume C Revision 2002-08
ML022470009
Person / Time
Site: Oconee  
(DPR-038, DPR-047, DPR-055)
Issue date: 08/28/2002
From: Mccollum W
Duke Energy Corp
To:
Document Control Desk, Office of Nuclear Security and Incident Response
References
Download: ML022470009 (48)


Text

S Duke Duke Energy Corporation Oconee Nuclear Station 7800 Rochester Highway Seneca, SC 29672 (864) 885-3107 OFFICE W. R. McCollum, Jr.

(64) 885-564 Fmc VicePresdent(864) 885-3564 FAx Vice President August 28, 2002 U. S. Nuclear Regulatory Coimmission Document Control Desk Washington, D. C.

20555

Subject:

Oconee Nuclear Station Docket Nos. 50-269, -270,

-287 Emergency Plan Implementing Procedures Manual Volume C Revision 2002-08 Please find attached for your use and review copies of the revision to the Oconee Nuclear Station Emergency Plan: Volume C Revision 2002-08 August 2002.

This revision is being submitted in accordance with 10 CFR 50-54(q) and does not decrease the effectiveness of the Emergency Plan or the Emergency Plan Implementing Procedures.

Any questions or concerns pertaining to this revision please call Rodney Brown, Emergency Planning Manager at 864-885-3301.

By copy of this letter, two copies of this revision are being provided to the NRC, Region II, Atlanta, Georgia.

Very truly yours, W. R Mc~ll 'Jr VP, Oconee N~udleSite xc:

(w/2 co ies of attachments)

Mr. Luis Reyes, Regional Administrator, Region II U. S. Nuclear Regulatory Commission 61 Forsyth St., SW, Suite 24T23 Atlanta, GA 30303 w/copy of attachments Mr. Steven Baggett Rockville, Maryland (w/o Attachments, Oconee Nuclear Station)

NRC Resident Inspector M. D. Thorne, Manager, Emergency Planning

August 28, 2002 OCONEE NUCLEAR SITE INTRASITE LETTER

SUBJECT:

Emergency Plan Implementing Procedures Volume C, Revision 2002-08 Please make the following changes to the Emergency Plan Implementing Procedures Volume C by following the below instructions.

REMOVE Cover Sheet -

Rev. 2002-07 Table of Contents, Page 1 & 2 HP/0/B/1009/022 -

(10/08/01)

RP/0/B/1000/029 -

(02/05/02)

ADD Cover Sheet Rev. 2002-08 Table of Contents, Page 1 & 2 HP/0/B/1009/022 -

(08/15/02)

RP/O/B/1009/022 -

(08/01/02)

DUKE POWER EMERGENCY PLAN IMPLEMENTING PROCEDURES VOLUME C APPROVED:

W. W. Foster, Manager Safety Assurance August 28, 2002 Date Approved August 28, 2002 Effective Date VOLUME C REVISION 2002-08 AUGUST 2002

HP/OIB/1009/018 HP/O/B/1009/020 HP/0IB11009/021 HP/OBI1009/022 RP/O/B/1000/001 RP/0/B/10001002 RPlOIBI 000/003 A RPIOIB/1000/007 RPIO/B/1000/009 RP/OIB/1000/010 RP/01B11000/015 A RP/0/B/1000/015 B RPIOIB/1I000/015 C RP/0/B/1000/016 RP/OJB/1l000/017 RP/O/B/1000/018 RPIOJB/1000/019 RPIO/B/1 000/020 RPIOJBI1 000/021 RP/O/B/1 000/022 RP/ OIB/1000/024 RPIOIB/1 000/02 8 VOLUME C TABLE OF CONTENTS Off-Site Dose Projections Estimating Food Chain Doses Under Post Accident Conditions Source Term Assessment Of A Gaseous Release From Non-Routine Release Points On Shift Off-Site Dose Projections Emergency Classification Control Room Emergency Coordinator Procedure ERDS Operation Security Event Procedure For Site Assembly Procedure For Emergency Evacuation/Relocation Of Site Personnel Offsite Communications From The Control Room Offsite Communications From The Technical Support Center Offsite Communications From The Emergency Operations Facility Medical Response Spill Response Core Damage Assessment Technical Support Center Emergency Coordinator Procedure Emergency Operations Facility Director Procedure Operations Interface (EOF)

Procedure For Site Fire Damage Assessment And Repair Protective Action Recommendations Communications & Community Relations World Of Energy Emergency Response Plan Revision 2002-08 August 2002 I

05/19/00 10/09/98 12/01/97 08/15102 06/19/02 03/21/02 12/03/98 11105101 02/19/02 04/24/01 12/11/01 12/11/01 12/11/01 01/30/01 05/29/02 09/30/97 05/20/02 12/05/01 04/30/01 07/16/02 11/10/99 02/17/97 I

RPIOIBI1000/029 RPIO/BI10001/031 SR/O/B/2000/001 Business Management SSG Functional Area Directive 102 NSC-110 Engineering Manual 5.1 Human Resources Procedure Radiation Protection Manual Section 11.3 Radiation Protection Manual Section 11.7 Safety Assurance Directive 6.1 Safety Assurance Directive 6 2 Training Division VOLUME C TABLE OF CONTENTS Fire Brigade Response Joint Information Center Emergency Response Plan Standard Procedure For Public Affairs Response To The Emergency Operations Facility Business Management Emergency Plan SSG Emergency Response Plan - ONS Specific Nuclear Supply Chain - SCO Emergency Response Plan Engineering Emergency Response Plan ONS Human Resources Emergency Plan Off-Site Dose Assessment And Data Evaluation Environmental Monitoring For Emergency Conditions Safety Assurance Emergency Response Organization Emergency Contingency Plan Training Division Emergency Response Guide DTG-007 Revision 2002-08 August, 2002 2

08/01/02 06/12/00 08107/01 03/21/01 03/01/01 04/02/01 07/17/02 01/07/02 04/06/99 11/26/01 11/28/94 03/27/00 12/17/01 I

-INFORMATION ONLY

ý_.PARATION (2)

Station (3)

Procedure Title Duke Power Company PROCEDURE PROCESS RECORD OCONEE NUCLEAR STATION On-Shift Off-Site Dose Projections (4)

Prepared By

&1 If //

ilit (5)

Requires 10CFR50.59 evaluation?

0 Yes (New procedure or revision with major changes)

I"'No (Revision with minor changes)

El No (To incorporate pre *

,jipoved changes)

(6)

Reviewed By (QR)

Cross-Disciplinary Review By (QR)NA bh!-e Reactivity Mgmt. Review By (QR)NA,

(7)

Additional Reviews Reviewed By Reviewed By (8)

Temporary Approval (if necessary)

By (SRO/QR)

Date 7/24/02 Date

"_Date Date Date Date Date

ýýBy

_,(QR)

Date (9)

Approved By

)

7 Date ij6-Joiii, PERFORMANCE (Coop re with control copy every 14 cunvar days while work is being performed.)

(10)

Compared with Con rol Copy Date Compared with Control Copy Date Compared with Control Copy Date (11)

Date(s) Performed Work Order Number (WO#)

COMPLETION (12) Procedure Completion Verification E1 Yes 11 NA Check lists and/or blanks initialed, signed, dated, or filled in NA, as appropriate?

o3 Yes EJ NA Listed enclosures attached?

11 Yes 11 NA Data sheets attached, completed, dated, and signed?

El Yes El NA Charts, graphs, etc. attached, dated, identified, and marked?

11 Yes El NA Procedure requirements met?

Verified By Date (13' Procedure Completion Approved Date

(,,_,Remarks (Attach additional pages, if necessary)

(1) ID No HP/OIB10091022 Revision No 009 404rLIS oehs/o Z.,

Duke Power Company Oconee Nuclear Station On-Shift Off-Site Dose Projections Reference Use Procedure No.

BPIOiBl lO091022 Revision No.

009 Electronic Reference No.

OX0092T4

HPIO /B/1009/022 Page 2 of 10 On-Shift Off-Site Dose Projections

1. Purpose 1.1 This procedure provides guidance for on-shift personnel to perform initial off-site dose projections using Raddose-V.

1.2 This procedure is an Emergency Plan Implementing Procedure (EPIP). It must be forwarded to the Emergency Planning Group within three working days of approval by the responsible group. {PIP 4-0-93-0701}

2. References 2.1 Earth Tech RADDOSE 5 Computer Program Documentation 2.2 EPA 400-R-92-001, Manual of Protective Action Guides and Protective Actions for Nuclear Incidents 2.3 Letter from M. S. Tuckman to USNRC, dated January 15, 1997, "Capability for On-Shift Dose Assessment at Catawba, McGuire, and Oconee Nuclear Sites" 2.4 PIP 4-0-93-701, Distribution Of Emergency Plan Procedures
3. Limits And Precautions 3.1 This procedure may be performed in sections or parts, using steps in any order to project off-site dose.

3.2 Accident release path(s) considered for on shift projections are the Unit Vents (LOCA) and the Steam Relief with Steam Generator Tube Rupture (SGTR).

3.3 This procedure is initiated at the request of the Operations Shift Manager/ Emergency Coordinator:

3.3.1 The Operations Shift Manager should specify the affected unit, and the release pathway in question (LOCA or SGTR).

3.4 Computers with Raddose-V are located in the RP Shift Lab (including laptop), TSC, OSC and the OSC Briefing Room.

3.5 Protective Action Recommendations (PARs) are made as follows:

3.5.1 Only after a General Emergency is declared are PARs made.

IHP/O/B/1009/022 Page 3 of 10 3.5.2 Plant conditions are expected to drive Emergency Action Levels and PARs. Upon declaration of General Emergency from the Control Room (as opposed to theTSC when established), default PARs are to recommend evacuation out to 5-miles around the plant and to shelter all remaining zones. On-Shift Offsite Dose projections are used to determine if zones between 5 to 10 miles away from the plant should be recommended for evacuation.

3.5.3 A recommendation to evacuate based on offsite dose is made when the forecast dose (Section 4.11 of this procedure) in a particular zone results in 1 rem or greater TEDE dose OR 5 rem or greater CDE thyroid dose:

] IF 1 rem or greater TEDE or 5 rem or greater CDE thyroid dose is projected, a General Emergency is declared if it was NOT declared previously, and PARs are made.

4. Procedure 4.1 IF Operations Shift Manager has NOT specified RIA indicating high activity, consult SDS to determine highest reading RIA in release pathway specified by Operations Shift Manager.

4.2 At applicable computer, select DAS (Dose Assessment Software).

NOTE:

If network is down, an error message will be displayed that network is unavailable. This will NOT affect the program, therefore continue to use Raddose-V.

4.3 Double-click left mouse button to select AFFECTED OCONEE UNIT'S RADDOSE-V (example: Raddose-V, Unit 1).

4.4 Single-click left mouse button on Drill Mode for emergency drill OR on Accident Mode for actual emergency.

PI/O/B/1009/022 Page 4 of 10 NOTE:

The drill simulator currently does NOT supply automatic data to Raddose-V, so when "Drill" mode is selected, "Manual" data loading should also be selected.

4.5 IF network is available, select AUTOMATIC data loading, if network is down, select MANUAL data loading:

NOTE:

Procedure default values of 16 degrees C for air temperature and 0 inches of precipitation may be used since these are standard/conservative values.

4.5.1 IF "Manual" data loading is selected, obtain meteorological, RIA AND Unit Vent flow rate data as required by Enclosure 5.1:

4.5.1.1 IF computer network is down AND Automatic Data is unavailable, collect data from SDS.

NOTE:

Manual meteorological charts and data are NOT available in the Control Rooms.

4.5.1.2 IF SDS is NOT available, collect data available from Control Room display and document on Enclosure 5.1.

4.5.1.3 IF Control Room indications are NOT available, utilize procedure defaults and indicate defaults were used on Enclosure 5.1.

4.6 At RADDOSE-V STARTUP MENU, select BEGIN NEW INCIDENT and select YES at prompt to erase previous data.

4.7 At ACCIDENT SCENARIO DEFINITION screen, perform the following:

NOTE:

o Current date and times from computer will appear as the reactor trip date and time and the release date and time.

0 If a reactor trip has NOT occurred or reactor trip time is NOT known, no editing of time is required.

4.7.1 Edit reactor trip time.

4.7.2 Edit release time:

4.7.2.1 IF actual release time is NOT known, input a time 15 minutes before current time (Example: current time is 0800 hours0.00926 days <br />0.222 hours <br />0.00132 weeks <br />3.044e-4 months <br />. The correct input is 0745).

4.7.3 Enter initials.

HP/0/B/1009/022 Page 5 of 10 4.7.4 Select ACCEPT at bottom of screen.

4.8 At MAIN MENU, single-click ENTER/EDIT METEOROLOGICAL DATA:

NOTE:

Raddose-V may select default meteorological data, depending upon time of day and River Wind Direction. This can occur if either "Automatic" OR "Manual" data is used.

4.8.1 IF "Automatic" data loading was selected, Raddose-V will automatically obtain data available from the network, proceed to Step 4.8.3.

4.8.2 IF "Manual" data loading was selected (or network data is NOT available), input required meteorological data on screen:

4.8.2.1 Select OK to acknowledge all error/pop-up messages.

4.8.2.2 Single click left mouse button at first block under "Wind Speed" (this will show a separate Wind Speed and Wind Direction table).

NOTE:

Entering data in field and pressing Enter moves cursor from field to field.

4.8.2.3 Enter data in Wind Speed and Wind Direction table:

  • Do NOT enter data in fields under "NWS" or under "Other" in Wind Speed and Wind Direction table.

4.8.2.4 Press F9 to exit table and to continue entering meteorological data.

4.8.2.5 Complete entry of data on Meteorological Data Input screen.

4.8.2.6 Select ACCEPT at bottom of screen.

4.8.2.7 Proceed to Step 4.9.

HPIOIBI1 009/022 Page 6 of 10 4.8.3 Review data in this time step:

4.8.3.1 IF no field shows "***" or "???", select "Accept" at bottom of screen and proceed to Step 4.9.

NOTE:

e If value of A-G for Stability Class is displayed on Raddose screen, it is NOT necessary to complete field below Delta Temperature, even though "***" or "???" may be present.

If data is NOT automatically loaded, procedure default values of 16 degrees C for air temperature and 0 inches of precipitation may be used since they are standard/conservative values.

4.8.3.2 IF any data field displays "***" or "???", obtain required data using.1 AND use Steps 4.8.3.3 through 4.8.3.5 to edit field.

4.8.3.3 Click left mouse button once to select data field requiring editing.

4.8.3.4 Type in value obtained using Enclosure 5.1 (Steps 4.5.1.1 - 4.5.1.3).

4.8.3.5 After data has been entered in all fields, select ACCEPT at bottom of screen.

4.9 At MAIN MENU, single-click ENTER/EDIT SOURCE TERM DATA:

4.9.1 Select first block under "Accident Type" data field.

4.9.2 Double-click left mouse button to select appropriate Accident Type; either LOCA or SGTR:

4.9.2.1 IF accident type is NOT known, contact Operations Shift Manager.

4.9.3 Select first block under "NG Method" (Noble Gas Method) to select pathway.

HP/OfB/1009/022 Page 7 of 10 4.9.4 At MONITOR DESCRIPTION MENU, double-click left mouse button for Affected Unit's radiation monitor as follows:

4.9.4.1 IF LOCA was chosen as accident type, select RIA-45, RIA-46 OR RIA-56:

A. Use RIA-45 if reading <1E7 cpm; B. Use RIA-46 if RIA-45 >lE7 cpm (offscale high); AND RIA-46

<lE7 cpm.

C. Use RIA-56 if RIA-46 >1E7 cpm (offscale high).

D. Select Filter Status "Off'.

E. Select OK.

NOTE:

  • If network is available, Raddose-V will input Unit Vent Flow Rate and RIA Reading.

0 If network is NOT available, these fields will require manual entry.

F. Continue at Step 4.9.5.

4.9.4.2 IF SGTR was chosen as accident type, select RIA 16 OR 17:

NOTE:

9 The RIA reading the highest (16 or 17) should be used as specified by Operations Shift Manager, SDS or Control Room indications.

  • If network is available, Raddose-V will obtain Steam Line RIA reading.
  • If network is NOT available, this field will require manual entry.

A. Select Steam Generator NOT Partitioned.

B. Select OK.

C. WhEN RIA 16 OR 17 is selected as NG Method, use default value of 4.5E6 pounds mass of steam per hour as the flow rate.

D. Continue at Step 4.9.5.

HP/0/B3/1009/022 Page 8 of 10 4.9.5 Review data in this time step:

4.9.5.1 IF no field shows "***" or "???", select "Accept" at bottom of screen and proceed to Step 4.10.

4.9.5.2 IF any data field displays "***" or "???", perform Steps 4.9.5.3 through 4.9.5.5 to edit field.

4.9.5.3 Select data field requiring editing.

4.9.5.4 Type in value obtained from Enclosure 5.1 or obtained directly from SDS or Control Room indications.

4.9.5.5 After all fields have been completed, select ACCEPT at bottom of screen.

4.10 At MAIN MENU, select PERFORM CALCULATIONS:

4.10.1 Select CONTINUE at bottom of 10-mile map.

4.10.2 At OUTPUT MENU, select GO TO REPORT MENU.

4.10.3 Select PRINT

SUMMARY

REPORT:

4.10.3.1 Select OK at Print Selector screen.

4.10.3.2 IF printer is NOT working, follow steps in Enclosure 5.2.

4.10.4 Select RETURN TO OUTPUT MENU.

4.10.5 Select RETURN TO MAIN MENU.

4.11 At MAIN MENU, select PERFORM FORECAST:

NOTE:

Forecast Period box will appear requiring you to enter the forecast period in hours 4.11.1 Input 1 and ENTER.

4.11.2 A pop-up message will display "Note: Forecast will use the meteorological and source term data from Step 1. Continue?" Select OK.

4.11.3 Select CONTINUE at bottom of 10-mile map:

4.11.3.1 A pop-up message will display "Do you want to save PAZs identified in Forecast Mode for evacuation?" Select NO.

4.11.4 At OUTPUT MENU, select GO TO REPORT MENU.

HP/On /1009/022 Page 9 of 10 4.11.5 At REPORT MENU, select PRINT GREEN FORM:

4.11.5.1 Select OK at Print Selector screen.

4.11.5.2 Obtain Emergency Notification Form (green sheet) printout.

4.11.5.3 IF printer is NOT working, follow steps in Enclosure 5.3.

NOTE:

Raddose-V will complete Lines 11, 12 and 14 on Emergency Notification Form (green sheet).

4.11.5.4 At Line 13, place an "X" in "New" box of the Raddose-V printout of the Emergency Notification Form (green sheet).

NOTE:

I If dose projections indicate evacuation and sheltering are necessary, Raddose-V will identify the affected Protective Action Zones (PAZs) in Line 15, items B and C.

4.11.5.5 At Line 15, IF no recommended Protective Action Zones are printed place an "X" in box A.

4.11.5.6 At Line 15, IF recommended Protective Actions are printed, place an "X" in boxes B and C.

4.11.5.7 IF dose projections indicate that ANY zone should be evacuated, recommend a General Emergency to Operations Shift Manager.

4.11.5.8 Refer to Enclosure 5.4 to assist in the completion of the Emergency Notification Form.

4.11.6 Provide Emergency Notification Form information (from Step 4.11.5) to Operations Shift Manager or designee.

4.11.7 Select RETURN TO OUTPUT MENU.

4.12 At OUTPUT MENU, select CONTINUE CALCULATIONS:

4.12.1 A pop-up message will display "You just completed a forecast. Remember to check the meteorological and source term data for current information".

Select OK.

4.13 At MAIN MENU, select GO TO STARTUP MENU.

HP/0/B/1009/022 Page 10 of 10 4.14 At STARTUP MENU, perform one of the following:

4.14.1 IF additional dose projections are NOT needed, per Operations Shift Manager request, select EXIT RADDOSE-V.

4.14.2 IF additional dose projections are needed, per Operations Shift Manager request, select BEGIN NEW INCIDENT:

4.14.2.1 Continue projections at frequency requested by Operations Shift Manager, repeating Steps 4.6 through 4.14.

4.15 Complete Procedure Process Record sign-off:

4.15.1 Transfer completed Procedure Process Record, Raddose 5 sheets and.1, 5.3 and 5.4 to Radiation Protection Staff personnel.

5. Enclosures 5.1 Manual Input Data Collection 5.2 Manual Recording Of Summary Report 5.3 Manual Recording Of Emergency Notification Form 5.4 Assisting In The Completion Of The Emergency Notification Form 5.5 Example Summary Report 5.6 Example Emergency Notification Form (green sheet)

.1 Manual Input Data Collection HP/O/B/1009/022 Page 1 of 1

  • Per Steps 4.5.1.1 through 4.5.1.3, record the following data from available data sources, (listed in order of preference); use defaults for temperature and precipitation; SDS; then actual Control Room displays if automatic data is NOT available to Raddose-V. Use the Default meteorological table only if SDS is NOT available. Obtain only the data needed, all blanks do NOT necessarily need to be filled in. This is an example form. Any other form that assists in collecting necessary data is acceptable.

METEOROLOGICAL DATA COLLECTION Use average meteorological data as displayed in SDS: Use precipitation and temperature values in Table: If all data is NOT available in SDS. Default data and Live data can he miixed_

10 METER TOWER 60 METER TOWER (Lower Level)

(Upper Level)

RIVER TOWER WIND SPEED WIND DIRECTION DELTA TEMP' NA NA TEMPERATURE °C ASSUME 16 NA NA PRECIPITATION ASSUME 0 NA NA T

Delta Temp = Temperature differential between 10 meters and 60 meters on Met Tower.

IF Meteorological Data is NOT available, input the following values:

10 METER TOWER 60 METER TOWER (Lower Level)

J (Upper Level)

RIVER TOWER WIND SPEED 1

1 1

WIND DIRECTION 140 140 140 DELTA TEMP1

+2.1 NA NA TEMPERATURE 0C 16 NA NA PRECIPITATION 0

NA NA T

Delta Temp = Temperature differential between 10 meters and 60 meters on Met Tower.

SOURCE TERM DATA COLLECTION IF data is NOT available through sources listed above (or Steps 4.5.1.1 through 4.5.1.3) this procedure CANNOT be completed.

MONITOR 7

UNIT 1 UNiT 2 UNIT3 RIA-45 cpm RIA-46 cpm RIA-56 R/hr UNIT VENT FLOW RATE cfm RIA-16 mR/hr RIA-17 mR/hr Main Steam Flow Rate Assume 4.5E6 Assume 4.5E6 Assume 4.5E6

.2 wP/O/B/1009/022 Manual Recording Of Summary Report Page 1 of 1 NOTE:

IFprinter problems occur and the Summary Report CANNOT be printed, this enclosure should be used to record data.

1. Use the following steps to record required information:

1.1 At REPORT MENU, select REVIEW

SUMMARY

REPORT.

1.2 Scroll up and down the report as necessary to access information (pages are separated by "dash" marks across the screen).

1.3 Copy information from Page 3 of Summary Report onto form at bottom of this enclosure.

1.4 On table below, circle highest "Emergency Class Criteria" that is marked with "*" on "Summary Report" screen.

1.5 WI-EN complete, select DONE at bottom of screen, continue at procedure Step 4.10.4.

CURRENT DATE:

STEP NUMBER:

1 CURRENT TIME:

STEP DATE:

NA OPERATOR:

STEP TIME:

NA Emergency Classification Based on Dose Rate @

NA (Specify)

Emergency Class Criteria Unusual Site General Dose Type 1.0 mi Sector Event Alert Emergency Emergency TEDE NA 1.14E-1 1.14E+1 100 1000 (mrem/hr)

(specify)

CDE Thyroid NA 3.42E-1 3.42E+1 500 5000 (mrem/hr)

(specify)

  • Identifies any value which exceeds the radiological action level.

.3 Manual Recording Of Emergency Notification Form HP/0/B/1009/022 Page 1 of 1 This enclosure should be used if printer problems occur and the Emergency Notification Form (green sheet) CANNOT be printed. Use the following steps to record required information, based on radiological conditions:

1.

At Report Menu, select DISPLAY GREEN FORM.

2.

Select NEXT PAGE at bottom of screen to access Lines 11 through 15 as necessary.

3.

Copy information from Lines 11, 12, and 14, of the displayed Emergency Notification Form, onto the form at the bottom of this enclosure.

4.

At line 13, place an "X" in the "New" box below and copy the remaining information.

5.

At line 15, of the Raddose-V display, perform the following:

"* IF no Recommended Protective Actions are displayed, place an "X" in box A below.

"* IF dose projections indicate evacuation and sheltering are necessary, Raddose-V will display the affected Protective Action Zones (PAZs) at boxes B and C. If applicable, copy this information onto the form below and check boxes B and C.

6.

Using Enclosure 5.2 or the "Summary Report" record Emergency Classification below.

7.

Select CANCEL or DONE at bottom of screen, then continue at Step 4.11.6.

  • 111.

TYPE OF RELEASE:

[

ELEVATED 0 GROUND LEVEL j[j AIRBORNE:

STARTED. ___.: _

!J Time (Eastern)

Date FB LIQUID:

STARTED: _.I:____

.J Time (Eastern)

Date

    • 12. RELEASEMAGNITUDE F71CuePerSec

[]Cui N

NOBLE GASES PARTICULATES STOPPED:

Time (Eastern)

Date "STOPPED:

Time (Eastern)

Date NORMAL OPERATING LIMITS: [] BELOW [] ABOVE E7I Lfs

    • 1.

ESTIMATE OF PROJECTED OFF-SITE DOSE.

NEW [] UNC SITE BOUNDARY 2 MILES 5 MILES 10 MILES TEDE mrem Thyroid CDE mrem

  • '14 METEOROLOGICAL DATA:

WIND DIRECTION (from)___

V\\ STABILITY CLASS IODINES OTHER N/A

[ANGED PROJECTION TIME:

Eastern ESTIMATED DURATION.

HRS.

N SPEED (mph)

N PRECIPITATION (type)

15.

RECOMMENDED PROTECTIVE ACTIONS-Emergency Classification (circle one)

W] NO RECOMMENDED PROTECTIVE ACTIONS None Unusual Event Alert FB EVACUATE Site Area Emergency General Emergency nI SHELTER IN-PLACE

[*

OTHER N/A

.4 Assisting In The Completion Of The Emergency Notification Form HP/0B/1009/022 Page 1 of 1 Raddose-V will print the Emergency Classification, based on Off-Site Dose on Page 3 of the "Summary Report" obtained at Step 4.10.3. Circle corresponding Emergency Classification at line 5 on Raddose-V printout of the Emergency Notification Form. If no Emergency Classification applies, write "NONE" on line 5 of the Emergency Notification Form. If the Emergency Notification form (green sheet) generated by Raddose-V recommends evacuation of a zone, circle "General Emergency" on the Raddose-V printout and recommend a General Emergency to the OPERATIONS SHIFT MANAGER (refer to the following note for more information).

NOTE:

Radiological Emergency Classification is based on dose rates at the Site Boundary (lmile). Under low wind speeds, Raddose-V may indicate low (or no) dose rates at 1 mile for a large release of activity. Then, after performing a forecast, evacuation might be recommended by Raddose. This is expected and is due to the low wind speed conditions.

"0 "Protective Action Recommendations" are either NO Protective Actions Necessary, or Evacuate Affected Zones. Whenever one or more zones are recommended for evacuation, sheltering of ALL other zones must be recommended. It is the responsibility of the Operations Shift Manager to determine which, if any zones should be recommended for evacuation.

For conditions when this procedure is used, if a General Emergency is declared, all zones out to 5 miles around the plant (AO, Al, B1, Cl, D1, El, and Fl) will be recommended to be evacuated by Operations.

Sheltering is recommended for all other zones. Dose Projections are performed primarily to determine if any zones beyond 5 miles should be evacuated.

Continue at Step 4.11.6.

C flit',

hII[

'1111

~1Ej~

-IA i~6ii~u h

g i g1.

"=1 ai ii!1 sag 11~

'I

iiij I B1

(JQ 0

0 b-I ul 0

0 0

'0 0

.5 Example Summary Report nHP/OJBllO09/022 Page 2 of 3 RADDOSE-V Version Rev 2.0 OCONEE NUCLEAR STATION - UNIT 1 Copyright 1996-98 Earth Tech REAL TIME MODE

SUMMARY

REPORT CURRENT DATE:

CURRENT TIME:

OPERATOR:

Total Release Rates:

NOBLE GAS IODINE PARTICULATE 09121198 DJB 2.56EI0O Cils 1.81 E-01 CiVs 9.05E-03 Ci/s STEP NUMBER:

STEP DATE:

STEP TIME:

1 09121198 12:15 Plume Arrival Times (Hrs) from 12:15 hours Distance (ml)

Arrival Time (hrs) 0.5 Arrived 1.00 Arrived 2.00 Arrived 5.00 0.68 hs @ time 12:50 10.00 1.42 hrs @time 13:40 Isotopic Spectrum 0.25 hour2.893519e-4 days <br />0.00694 hours <br />4.133598e-5 weeks <br />9.5125e-6 months <br /> after Reactor Trip Based on Source Term LOCA Relative PercentAbundance at Time 12:15 Noble Gases Kr85 Kr85m Kr87 Kr88 Xe131rm Xe133 Xe133m Xe135 Xe138 lodines 1131 1132 1133 1134 1135 0.712%

0.821%

0A60%

1A78%

0.657%

90.884%

1.259%

3.449%

0.279%

Particulates 23.M6%

29A57%

28.682%

3.876%

14.729%

Sr89 Sr90 Y91 Rul06 Te132 Cs134 Cs136 Cs137 Ba140 Ce144 5.882%

0.480%

11.763%

0.061%

12.134%

12.134%

6.501%

40.242%

10.370%

0.433%

CURRENT DATE:

CURRENT TIME:

OPERATOR:.5 Example Summary Report RADDOSE-V Version Rev 2.0 OCONEE NUCLEAR STATION - UNIT I Copyright 1996-98 Earth Tech REAL TIME MODE

SUMMARY

REPORT 09121198 STEP NUMBER:

15:21 STEP DATE:

DJB STEP TIME:

HP/O/B/1009/022 Page 3 of 3 1

09121198 12:15 Emergency Classification Based on Dose Rate @ 09/21198 12:15 : Alert Dose Type Unusual 1.0 mi Sector Event Emergency Class Criteria Site Alert Emergency General Emergency TEDE (elh 1.16E+01 SSW(K) 1.14E-1*

1.14E+I" 100 1000 (mrem/hr)

CDE Thyroid 1.99E+02 SSW(K) 3.42E-1 3.42E+1-500 5000 (mremnhr)

  • Identifies any value which exceeds the radiological action level Unusual Event Is based upon 2 times the SLC value Alert Is based upon 200 times the SLC value Site Emergency is based upon one tenth of the Protective Action Guides General Emergency is based upon the Protective Action Guides TEDE Is Total Effective Dose Equivalent CDE is Committed Dose Equivalent (Thyroid, Adult)

Self Reading Dosimeter (SRD) Correction Factor SRD Correction Factor= [TEDEI(Plume EDE + Ground Shine)]

Maximum SRD Correction Factor at the Site Boundary =

2.74E+00 PROVIDE SRD CORRECTION FACTOR to EMERGENCY WORKERS

.6 HP/OIBI1oo9Io22 Example Page 1 of 2 Emergency Notification Form (Green Sheet)

  • ~ A- [] THIS ISA DRILL. B. 1@ ACTUAL EMERGENCY [:] ITITW E] FOLLOW~4JP MESSAGE It' JR
2. SITE:

Oconee UNIT. i REPORTED B-___________________

3. TRANS3~UTTALTW"7EIDTE I

I CONFIRMATMO PHONE NUMBER

4. AJJTHENTICATION (If Requhr*~

(N~mnber)(Codewvrd)

&EUERGENCY CLAS5IF1CATTON. A.

NOTIFIMCATION OF UNUSUAL LVENTI 6.-

nr]Ewmorgn Do*~Ijon At [E T*wIk~cn At TIEM ETE.......--

.. L.J.. (If B., go I* Itmn 16)

(EasWM) aMM 6dd

7. EMERGENCY OESCRPTIONSRENIARK$

8PLANT CONOMM, W~ IMM IMR~N LO DL DERUIN

9. FREACTIOR STATUS:[H SIJTUOWK TIMEMDTE:

J__ J_

[]

j POWER 10, EMERGENCY RELEASE(S)

(Ewtm) mm dd yy A (jNONE (Go to hem 14)

BM Q]POTENTIAL (GoI*toem 14)

OQI1SOCCURRING

.Of]HASOCCURRED

"-11.

YPE OF Ra-EAM Q ELEATFD O GROUND LEVEL MAIRBORNE--

STARTED:

1200

- OMt2I986 STOPPED:

Trem{EastoM)

D0i50 TOMs (Ezamnm)

Deats Time (Eastem)

D05*

This (Eostam)

Daft

'"1Z RELEASE MAGNITUDE: CR Cwles Per Sec C]Curios NORMAL OPER~ATING tUMItM (BELOW M ABOVE NOBLE GAES 2ZSEOO ICOlNIES, 181E-01 PARTICULATES 9.055-03

[]OTHER

-I3. ESTIMATE OF PROJECTED OFFSITIE DOGE.- Q NOW E3 UNCHANtGED PROJECTION TIME--tIB1 TEDE (mnrm)

Thyroid CDE (nwoin) rsaam) 1IEONDR A5E401 2ABE402 2 WLES 2.g3Etc 4.97E#0I ESTIMATED OURATPON 1.25 HIMS 5 LtdLES 3..93&O

&79F-+00 10 MILES 0AVE4OO 0A~0E+00 014. METEOROL.OGICAL DATA:

1WW W INORECTION (O.M) 20.D dog"~

SPEED (Msph)

&.0

[JSTABILITY CLASS B

ME)

PReCIPrTATON ("wypowi000 i$ri A-NO RECOIMUENOEO PROTECTIVE ACTIONS$

B.

EVACUATE C, [3 814ELME JN4.PUC

0. [] OTHER
18. APPROVED

,Y________________

________AEADATE.

9 f tem. 8-14 how not dwqed. ot w 1-7 wW 16-1) weu~n

.uuk tod beyyp

" Infnrh ma no be avi an kintli mtkn

~

ia~~ tb.vIwMe

.6 Example Emergency Notification Form (Green Sheet)

H.P/OIB/1009/022 Page 2 of 2 This page is for internal use only. Do -not.-FAX, The accumublted dom at the site, boundtary Ws Z90+0 since the beginning of Owe release 41.6E+11 This Inibrmation Io tak~en from milrom (MMD) nm~rem, (CDE Thyroid)

MRaddose-V estimate.

ThMp~'r~n ito dose C adiD3TSulSshould b se o sit h Nw Goz and/or The coprwnX~ gpolcesepern In SuiritiMn11 the above exnosure to the Publitcflrough jiewsreleases.

Oo mpads o ns-In min PI yrnft.)

Exposure recei6vad from 10 routine, Xqra of fth arm or leg.

(NUREG/R-01 60)

Exposure received diming a crs-ountry flight.

(NCRP Report H0. 941,11987)

Exposure from a single d~gnostic ches Xqray.

(NUREGIR-01 50 Aninual dose womiibaent timit. to any individual member of the puaiftc from the lcensed operation of a nuclear powe faifty.

(IOCFR20, A~ppdx& B, TWOe 2)

Routine Uppe GI series Xq.ry (NCRP Report No. 100, 1989)

Aveiage annual excposure, to Uie U population from an souv~e

~IudIng radon, (NCRP Rap~fNo-94. 1.987)

EPA Protective Action Guide for the public evacuation and/or shelter.

(EPA-400)

Annutil occigatoral Uitn for nuclear power ptani wofter.

(10CFR20.1201(i))

I 260 360 1000 6000 09MMI~

I M 16

NSD 703 (R04-01)

Duke Power Company

.INFORMATOtDuRE PROCESS RECORD ONLY T

",PARATION

\\._

Station (3)

Procedure Title (1) D No. RPIOJBl1000I29 Revision No. 005 OCONEE NUCLEAR STATION Fire Brieade Response

,91 (4)

Prepared By Rodney Brown (Signature) 1 Date 08/01/2002 (5)

Requires NSD 228 Applicability Determination?

0 Yes (New procedure or revision with major changes)

[] No (Revision with minor changes)

[] No (To incorporatey"]usly app (6)

Reviewed By (QR)

Date Cross-Disciplinary Review By (QR)NA Date Reactivity Mgmt Review By (QR)NA Date Mgmt Involvement Review By (Ops Supt) NA Date (7)

Additional Reviews Reviewed B (qe..

Date Reviewed By Date K'",

(8)

Temporary Approval (if necesiary)

<_By (OSMIQR)

Date By (QR)

Date (9)

Approved By Date J0-

- o2 PERFORMANCE (Compare with control copy every 14 calendar days while work is being performed.)

(10) Compared with Control Copy Date Compared with Control Copy Date Compared with Control Copy Date (11)

Date(s) Performed Work Order Number (WO#)

COMPLETION (12) Procedure Completion Verification:

E0 Unit 0 El Unit 1 0l Unit 2 El Unit 3 Procedure performed on what unit?

"El Yes Dl NA Check lists and/or blanks initialed, signed, dated, or filled in NA, as appropriate?

"El Yes 0l NA Required enclosures attached?

"El Yes El NA Data sheets attached, completed, dated, and signed?

"El Yes El NA Charts, graphs, etc. attached, dated, identified, and marked?

"El Yes El NA Procedure requirements met?

Verified By Date

(,.._Procedure Completion Approved Date (14) Remarks (Attach aJdditional pages)

Duke Power Company Oconee Nuclear Station Fire Brigade Response Reference Use Procedure No.

RP/OIBIl1000/029 Revision No.

005 Electronic Reference No.

OXOO91UU I

RP/OJB/1000/029 Page 2 of 3 Fire Brigade Response NOTE:

This procedure is an implementing procedure to the Oconee Nuclear Site Emergency Plan and must be forwarded to Emergency Planning within seven (7) working days of approval.

1. Symptoms 1.1 Fire, explosions or conditions (smoke, smoldering, burning) associated with a fire have been reported to the Control Room or to the OSC when activated.

1.2 This procedure shall provide guidance to shift personnel and Emergency Coordinator for response, actions, and coordination associated with an incident involving real or suspected fires.

2. Immediate Actions 2.1 IF Fire Brigade response is being considered during routine operations THEN Go to Enclosure 4.1 (Fire Brigade Response - Routine Operations) 2.2 IF Fire Brigade response is being considered AND The OSC/TSC are activated THEN Go to Enclosure 4.2 (Fire Brigade Response - OSC/TSC Activation).
3. Subsequent Actions 3.1 WHEN HPSW Pump NO longer required perform the following:

3.1.1 Ensure HPSW Pump switch returned to required position per OP/0/A/1 104/011 (High Pressure Service Water).

3.1.2 If required reset Mulsifyres per OP/0/A/1104/011 (High Pressure Service Water).

3.1.3 If required close any Fire Hydrant that was opened. {4}

3.2 IF Fire Brigade equipment or supplies have been used, THEN Ensure that all equipment is returned to its proper place and consumable supplies are replaced or ordered.

RP/O[B/10001029 Page 3 of 3 NOTE:

Original copies of the Fire Emergency Report can be located in NSD 112, Fire Brigade Organization and Training.

3.3 Complete Enclosure 4.3 (Fire Emergency Report).

S3.3.1 Forward a copy to the Fire Protection Engineer.

S3.3.2 Initiate a PIP if Enclosure 4.3 (Fire Emergency Report) is completed. Include all important information from Enclosure 4.3 (Fire Emergency Report) in PIP.

3.3.3 Forward this procedure to the Emergency Planning Section.

3.4 Conduct a post incident critique for events requiring full Fire Brigade activation.

4. Enclosures 4.1 Fire Brigade Response - Routine Operations 4.2 Fire Brigade Response - OSC/TSC Activation 4.3 Fire Emergency Report 4.4 Fire Brigade Leader Checklist 4.5 Safety Officer's Checklist 4.6 References

.1 Fire Brigade Response - Routine Operations

1. Fire Brigade Response - Routine Operations

"* Actions may be followed in any sequence.

"* Lines left of procedure steps are used to indicate place in procedure.

"* Check marks are acceptable in these blanks.

"* Complete the procedure steps that apply to this incident.

"* N/A steps not performed.

S1.1 Complete the following with information taken from the caller:

Name/Group of person reporting fire/smoke RP/O/B/1000/029 Page 1 of 8 Location of fire/smoke Equipment/components affected by fire/smoke Time Date Are there people in the immediate area who need to be warned or relocated to a safe area?

Are there any injured people?

Call back number Notify OSM and STA.

Refer to the Fire Plan for the location reported for fire in Step 1.1 1.3.1 Request support from an unaffected unit. (Refer to Fire Plan SOG #10 for Fire Brigade equipment locations).

1.2 1.3

.1 Fire Brigade Response - Routine Operations 1.4 IF THEN 1.4.1 1.4.2 RP/O/B/1000/029 Page 2 of 8 Fire is involved or suspected INSIDE the protected area Perform the following:

Send one operator, with a radio, to the fire/smoke location to perform one of the following:

A. Extinguish the fire (if possible) with portable extinguisher (notify Control Room)

OR B. IF Fire Brigade response is required THEN Notify Control Room immediately.

IF Fire Brigade response is NOT needed THEN Perform the following:

A. Direct NEO to Search affected area for victims

" Activate MERT if required per RP/O/B/1000/016, Medical Response.

" IF NO fire was discovered then exit this procedure.

" If fire was discovered then GO TO Step 1.4.8.

NOTE:

The Operations Shift Manager (OSM) or designee may activate a full Fire Brigade response without sending someone to investigate first, if deemed necessary. Possible situations that warrant full response could include:

"* Multiple reports from individuals

"* Multiple alarms,

"* Other system indications

"* Any other indicators that the Operations Shift Manager deems significant.

1.4.3.1 RP/OJB/1000/029 Fire Brigade Response - Routine Operations Page 3 of 8 IF A full Fire Brigade response is needed THEN Perform the following:

A. Direct NEO to:

"* Search effected area for victims

"* Evacuate surrounding areas

"* Pre-stage nearby equipment for Fire Brigade

"* Report to Fire Brigade Leader for further instructions B. Use plant page to request all Fire Brigade and MERT members to respond to the fire.

1. Include any information, if known, that would be important to Fire Brigade members responding to the incident location. (eg. Hazardous materials, smoke, structural damage, etc.)
2.

Include the statement "All non-Fire Brigade personnel please avoid the "1

." (fire location area) 1.4.4 Use the following directions to activate radios and pagers.

A. Transmit "Standby for Emergency Message" B. Press the "Instant Call" button labeled "Fire Brigade" C. Wait for the red "Transmit" light on the radio to turn off D. Transmit message including information, if known, that would be important to Fire Brigade members responding to the staging area (e.g. hazardous materials, smoke, structural damage, etc.).

1.4.5 Get staging area location from the Fire Brigade Leader then repeat Steps 1.4.3.B & 1.4.4.

1.4.6 Notify SRO to evaluate the need for staging personnel at the SSF.

1.4.7 Establish and maintain communications with Fire Brigade Leader to provide assistance as needed. {3}

A. Available equipment, refer to SOG #10 in the Fire Plan.

B.

Critical equipment in vicinity of fire (Fire Plan)

.1 Fire Brigade Response - Routine Operations RPIOJB/1000/029 Page 4 of 8 1.4.8 IF Hazardous materials are involved, THEN Refer to RP/OJB/1000/017 (Spill Response Procedure).

1.4.9 IF An oil filled transformer is involved in a fire, THEN Request Oconee County Fire Department to dispatch the Keowee Key Fire Department to the site.

from Ext. 3271 from Ext. 2159 from 882-7076 Operations Shift Manager's phone Unit I Control Room SRO's phone or Units 1, 2 and 3 Control Rooms, Bell South lines 1.4.10 IF The Fire Brigade identifies a fire requiring application of water for extinguishment, THEN perform the following:

NOTE:

These steps are in order of preference.

A. Perform one of the following:

1. Activate Mulsifyre Transformer No. 3Y [3Y Currently spare] (T-3-B42)

OR

2.

Activate any one of the following (preferably not loaded or energized):

"* Mulsifyre Transformer CT-I (T-3-B 14)

"* Mulsifyre Transformer No.CT-2 (T-3-D29)

"* Mulsifyre Transformer No.CT-3.

(T-3-B42)

OR

3.

Remove cap and open any fire Hydrant within protected area or switchyard with a 2.5" outlet.

NOTE:

HPSW Pump should be started <30 minutes from start of fire.

B. Start HPSW Pump per OP/0/A/1 104/011 (High Pressure Service Water).

{1}{4}

C. Make a PA announcement to discontinue use of HPSW for non-essential purposes. {1}

D. Evaluate any Auxiliary Building Flooding Concerns (Refer to Auxiliary Building Flood AP). {2}

Dial 9-911 Dial 9-911 Dial 911

.1 RP/O/B/1000/029 Fire Brigade Response - Routine Operations Page 5 of 8 1.4.11 IF Fire occurs on backshifts or weekends AND Additional Fire Brigade support is needed, THEN Perform the following:

A. Select the off duty shift(s) that will impact the safe operation of the plant the least by being recalled (i.e., shifts other than on coming shift).

A B

C D

E B.

Call the Switchboard Operator and request them to call the shift(s) selected in Step A.

NOTE:

All site phones except for the following are blocked from accessing the public 911 emergency service line.

1.4.12 IF Oconee County Fire Department assistance is needed, THEN Dial 9-911 from Ext. 3271 Operations Shift Manager's phone Dial 9-911 from Ext. 2159 Unit 1 Control Room SRO's phone Or Dial 911 from 882-7076 Units 1/2 and 3 Control Rooms, Bell South lines A. Request a response from:

Keowee Key Fire Department Keowee Ebenezer Fire Department Corinth-Shiloh Fire Department

"* Give the fire location (building, parking lot, etc.) and best gate for entry to the fire department dispatch.

"* Call Security (ext. 2222) and request that they have a Security Officer escort the fire department to the fire location.

.1 Fire Brigade Response - Routine Operations RPIOJBI1000/029 Page 6 of 8 Fire is involved or suspected OUTSIDE the Protected Area, THEN Call Security (ext. 2222) and request that a Security Officer be dispatched to the suspected fire location to verify fire location and nature of the fire.

Request Security Shift Supervisor to relay information back to the Control Room via the emergency line (4911).

1.5.1 IF Security confirms that there is a fire or the situation has the potential for developing into one, THEN Send a Fire Brigade Leader and one Fire Brigade Member or the full Fire Brigade if resources allow.

NOTE:

Offsite fire departments are normally responsible for fire suppression activities outside the Protected Area. The Fire Brigade may provide limited support for a fire outside the Protected Area if resources allow.

"* The Fire Plan for Keowee Hydro calls for sending the Fire Brigade to extinguish fires there.

Security will automatically send a Security Officer to investigate alarms on fire detection systems that are monitored by Security in the PAP. Security will call the emergency line to report the existence of a fire or a need for further investigation by plant personnel as needed.

1.5 IF

.1 Fire Brigade Response - Routine Operations RP/OJB/1000/029 Page 7 of 8 1.5.2 IF The Fire Brigade identifies a fire requiring application of water for extinguishment THEN Perform the following:

NOTE:

These steps are in order of preference.

A. Perform one of the following:

1. Activate Mulsifyre Transformer No. 3Y [3Y Currently spare] (T-3-B42)

OR

2.

Activate any one of the following (preferably not loaded or energized):

"* Mulsifyre Transformer CT-1 (T-3-B14)

"* Mulsifyre Transformer No.CT-2 (T-3-D29)

"* Mulsifyre Transformer No.CT-3.

(T-3-B42)

OR

3.

Remove cap and open any fire Hydrant within protected area or switchyard with a 2.5" outlet.

NOTE:

HPSW Pump should be started *30 minutes from start of fire.

B. Start HPSW Pump per OP/0/A/1104/011 (High Pressure Service Water).

{1} {4}

C. Make a PA announcement to discontinue use of HPSW for non-essential purposes. { 1}

NOTE:

All site phones except for the following are blocked from accessing the public 911 emergency service line.

IF Oconee County Fire Department assistance is needed, THEN Dial 9-911 Dial 9-911 Dial 911 from Ext. 3271 Operations Shift Manager's phone from Ext. 2159 Unit 1 Control Room SRO's phone or from 882-7076 Units 1/2 and 3 Control Rooms, Bell South line 1.5.3

.1 Fire Brigade Response - Routine Operations RP/O/B/1000/029 Page 8 of 8 1.5.4 Request a response from:

Keowee Key Fire Department Keowee Ebenezer Fire Department Corinth-Shiloh Fire Department Give the fire location (building, parking lot, etc.) and best gate for entry to the fire department dispatch.

Call Security (ext. 2222) and request that they have a Security Officer escort the fire department to the fire location.

NOTE:

Keowee Hydro Station is located in Pickens County. Dialing 9-911 will NOT access the Pickens County Fire Dispatch.

1.5.5 IF Six Mile Fire Department assistance is needed for a fire at Keowee Hydro Station, THEN Call the Pickens County Sheriffs Department (898-5500) and request the response of Six Mile Fire Department to Keowee Hydro Station.

Call Security (ext. 2222) and request that they have a Security Officer escort the fire department to the fire location.

1.6 Return to Section 3, Subsequent Actions.

.2 RP/O/B/1000/029 Fire Brigade Response - OSC/TSC Activation Page 1 of 7

1. Fire Brigade Response - OSC/TSC Activation

"* Actions may be followed in any sequence.

"* Lines left of procedure steps are used to indicate place in procedure.

"* Check marks are acceptable in these blanks.

"* Complete the procedure steps that apply to this incident.

"* N/A steps not performed.

1.1 Complete the following with information taken from the Work Control Assistant who received the emergency line call:

Name/Group of person reporting fire/smoke Location of fire/smoke Equipment/components affected by fire/

Time Date Are there people in the immediate area who need to be warned or relocated to a safe area?

1.2 Are there any injured people?

Call back number Refer to Fire Plan for the location reported for fire in Step 1.1.

1.2.1 Request support from an unaffected unit. (Refer to Fire Plan SOG#10 for Fire Brigade Equipment locations).

.2 Fire Brigade Response - OSC/TSC Activation RP/OJB/1000/029 Page 2 of 7 NOTE:

The Emergency Coordinator or designee may activate a full Fire Brigade response without sending someone to investigate first, if deemed necessary. Possible situations that warrant full response could include:

"* Multiple reports from individuals

"* Multiple alarms,

"* Other system indications

"* Any other indicators that the Emergency Coordinator deems significant.

1.3 IF Fire is involved or suspected INSIDE the Protected Area, THEN Perform one of the following as required.

1.3.1 Send one operator, with a radio, to the fire/smoke location to perform one of the following:

A. Extinguish the fire (if possible) with portable extinguisher (notify Control Room)

OR B. IF Fire Brigade response is required THEN Notify Control Room immediately.

1.3.2 IF Fire Brigade response is NOT needed, THEN Perform the following:

A. Direct NEO to search affected area for victims B. Activate MERT if required per RP /OBII1000/016 (Medical Response)

C. IF NO fire was discovered then exit this procedure.

D. If fire was discovered then GO TO Step 1.3.5.

.2 RP/O/B/1000/029 Fire Brigade Response - OSC/TSC Activation Page 3 of 7 1.3.3 IF A full Fire Brigade response is needed, THEN Perform the following:

A. Direct NEO to:

"* Search effected area for victims

"* Evacuate surrounding areas

"* Pre-stage nearby equipment for Fire Brigade

"* Report to Fire Brigade Leader for further instructions B. Dispatch Fire Brigade Members assigned to the OSC to respond to the fire.

C. Request the OSC Security Manager to have MERT respond along with the Fire Brigade to the fire location.

1.3.4 Establish and maintain communications with Fire Brigade Leader to provide assistance as needed. {3}

A. Available equipment (Refer to SOG #10 in the Fire Plan)

B.

Critical equipment in vicinity of fire (Fire Plan) 1.3.5 IF Hazardous materials are involved, THEN Refer to RPIOIBIO001/017 (Spill Response Procedure).

1.3.6 IF An oil filled transformer is involved in a fire, THEN Request Oconee County Fire Department to dispatch the Keowee Key Fire Department to the site.

Dial 9-911 from Ext. 3271 Operations Shift Manager's phone Dial 9-911 from Ext. 2159 Unit 1 Control Room SRO's phone or Dial 911 from 882-7076 Units 1, 2 and 3 Control Rooms, Bell South lines

.2 RP/O/B/1000/029 Fire Brigade Response - OSC/TSC Activation Page 4 of 7 1.3.7 IF The Fire Brigade identifies a fire requiring application of water for extinguishment, THEN Perform the following:

NOTE:

These steps are in order of preference.

A. Perform one of the following:

1. Activate Mulsifyre Transformer No. 3Y [3Y Currently spare] (T-3-B42)

OR

2.

Activate any one of the following (preferably not loaded or energized):

"* Mulsifyre Transformer CT-1 (T-3-B14)

Mulsifyre Transformer No.CT-2 (T-3-D29)

"* Mulsifyre Transformer No.CT-3.

(T-3-B42)

OR

3.

Remove cap and open any fire Hydrant within protected area or switchyard with a 2.5" outlet.

NOTE:

HPSW Pump should be started<5 30 minutes from start of fire.

B.

Start IHPSW Pump per OP/O/A/I 104/011 (High Pressure Service Water).

{1} {4}

C. Make a PA announcement to discontinue use of HPSW for non-essential purposes. { 1 }

D. Evaluate any Auxiliary Building Flooding Concerns (Refer to Auxiliary Building Flood AP). {2}

1.3.8 Notify SRO to evaluate the need for staging personnel at the SSF.

1.3.9 IF Fire occurs on backshifts or weekends AND Additional Fire Brigade support is needed, THEN Perform the following:

A. Select the off duty shift(s) that will impact the safe operation of the plant the least by being recalled (i.e., shifts other than on coming shift).

A B

C D

E B. Call the Switchboard Operator and request them to recall the shift(s) selected in Step A.

.2 Fire Brigade Response - OSC/TSC Activation 1.3.10 IF RP/O/BI l000/029 Page 5 of 7 Oconee County Fire Department assistance is needed, THEN Request that the Offsite Communicator call and request a fire department response from:

"* Keowee Key Fire Department

"* Keowee-Ebenezer Fire Department

"* Corinth Shiloh Fire Department A. Give the fire location (building, parking lot, etc.) and best gate for entry to the Offsite Communicator so that it can be given to the fire department dispatcher.

B. Request that a Security Officer meet and escort the fire department to the fire location.

1.4 IF THEN 1.4.1 Fire is involved or suspected OUTSIDE the Protected Area, Request that a Security Officer be dispatched to the suspected fire location to verify the location and status of the fire. Request that information be relayed back to the OSC via the emergency line (4911).

IF Security confirms that there is a fire or the situation has the potential for developing into one, THEN Send a Fire Brigade Leader and one Fire Brigade Member or the full Fire Brigade if resources allow.

NOTE:

  • Offsite fire departments are normally responsible for fire suppression activities outside the Protected Area. The Fire Brigade may provide limited support for a fire outside the Protected Area if resources allow.

"* The Fire Plan for Keowee Hydro calls for sending the Fire Brigade to extinguish fires there.

Security will automatically send a Security Officer to investigate alarms on fire detection systems that are monitored by Security in the PAP. Security will call the emergency line to report the existence of a fire or a need for further investigation by plant personnel as needed.

1.4.2.2 RP/O/B/1000/029 Fire Brigade Response - OSC/TSC Activation Page 6 of 7 IF The Fire Brigade identifies a fire requiring application of water for extinguishment, THEN Perform the following:

NOTE:

These steps are in order of preference.

A. Perform one of the following:

1. Activate Mulsifyre Transformer No. 3Y [3Y Currently spare] (T-3-B42)

OR

2.

Activate any one of the following (preferably not loaded or energized):

"* Mulsifyre Transformer CT-1 (T-3-B 14)

"* Mulsifyre Transformer No.CT-2 (T-3-D29)

"* Mulsifyre Transformer No.CT-3.

(T-3-B42)

OR

3.

Remove cap and open any fire Hydrant within protected area or switchyard with a 2.5"outlet.

NOTE:

HPSW Pump should be started *30 minutes from start of fire.

B. Start HPSW Pump per OP/01A/1104/011 (High Pressure Service Water).

{1} {4}

C. Make a PA announcement to discontinue use of HPSW for non-essential purposes. {1}

.2 RP/O/B/1000/029 Fire Brigade Response - OSC/TSC Activation Page 7 of 7 1.4.3 IF Oconee County Fire Department assistance is needed, THEN Request that the Offsite Communicator call and request a fire department response from:

"* Keowee Key Fire Department

"* Keowee-Ebenezer Fire Department

"* Corinth Shiloh Fire Department A. Give the fire location (building, parking lot, etc.) and best gate for entry to the Offsite Communicator so that it can be given to the fire department dispatcher.

B. Request that a Security Officer meet and escort the fire department to the fire location.

NOTE:

Keowee Hydro Station is located in Pickens County.

1.4.4 IF Six Mile Fire Department assistance is needed for a fire at Keowee Hydro

Station, THEN Request the Offsite Communicator call the Pickens County Sheriffs Department (898-5500) and request Six Mile Fire Department to respond to Keowee Hydro Station.

Request that a Security Officer meet and escort the fire department to the fire location.

1.5 Return to Section 3, Subsequent Actions.

.3 Fire Emergency Report FIRE EMERGENCY REPORT Station/Location:

Location (Unit/Area):

Time Discovered:

Operations Shift Manager:

RpIOIBI1000/029 Page 1 of 1 Date:

Discovered By:

Evacuation: Yes No Partial Fire Brigade Response: Yes No Time Fire Extinguished:

List All Fire Protection Equipment Used Other Operation Satisfactory: Yes No (Use Back For Details)

Equipment Restored For Use: Yes _

No If no, Explain (Use Back for Details)

Outside Assistance Called: No Yes Agency(s)

Area Involved:

  • Point of Origin (If known):

Cause (If known Damage To:

Building Equipment Personal Other Injuries Reported:

Briefly Describe What Happened:

  • Signature of Fire Brigade Leader
  • Signature of Operations Shift Manager "
  • Notify Safety Representative of Fires Involving Personal Injury (Refer to Duty List for after hours).

.4 Fire Brigade Leader Checklist RP/O/B/1000/029 Page 1 of 1 TASK Don Fire Brigade Leader Vest Determine Staging Area and Communicate to Control Room

"* Safe accessibility

"* Minimal distractions

"* Appropriate vicinity Establish The Following Teams/Priorities:

"* Entry Team - Priority = search & rescue/fight fire

"* Backup Team - Priority = backup Entry Team/help fight fire

"* Rapid Intervention Team - Priority = Rescue Fire Fighters (if required)

Stress The Following Items With All Teams Prior To Dispatching To Fire:

"* Safety of Team is top priority

"* Stay with the hose/rescue line at all times

"* Maintain contact with your team at all times

"* All teams report to Safety Officer prior to entering fire zone and after exiting fire zone for accountability Assess The Fire:

"* Request CR to dispatch additional resources as required:

Off Duty Shifts and/or Offsite Fire Departments Outside Equipment Truck and/or Equipment Carts C02 or Wheeled Dry Chemical Extinguishers Foam Units

"* Exposures - Critical Equipment Concerns Above/Below Fire?, Fire/Smoke/Water?, Electrical Hazards?

"* Report Critical Equipment Concerns to CR for Emergency Plan Consideration Request Location of Nearest Fire Hose Locations From Control Room:

"* Elevation/column #

"* Communicate locations to teams Request Assistance From RP/Security 0 Request Security At The Scene To Control Access To The Area

  • If Radiological Concerns Exist, Request CR To Notify RP Refer To Fire Plan As Required:

"* Hazards/Ventilation

"* Refer To SOG #10 for Fire Brigade equipment locations If Hazardous Materials Involved, Request CR to Dispatch Haz-Mat Team

.5 Safety Officer's Checklist RPiO/BIlO/001029 Page 1 of 1 TASK Don Safety Officer Vest Establish Accountability For FB Members

  • Name tags/accountability board Perform PPE Checks of Fire Fighters

"* All skin covered

"* All turnout gear openings closed

"* SCBA cylinder full (> 4000 psi)

"* SCBA cylinder valves fully open

"* PASS device operational Log Team Assignments on Accountability Board

"* Log time on air

"* Log entry times

"* Log team assignments Assign MERT Responsibilities

"* Stand by with medical equipment

"* Monitor FB members for signs of heat exhaustion/stress/etc.

"* Provide drinking water for fire fighters Maintain Continuos Contact With Fire Brigade Leader Evaluate SCBA Needs

"* If required, request CR to have SCBA cylinder fill trailer delivered

"* If required, request CR to have Spare SCBA cylinders delivered.

"* If required, request CR to have spare SCBAs (for additional responders) delivered

.6 References RP/OIB/IO00/029 Page 1 of 1

References:

{1}

PIP 01-0405

{2}

PIP 99-1286

{3}

PIP 01-1220

{4)

PIP 02-03870