Technical Specifications Amendment Request for Additional Information (RAI) Implementation of 10 CFR 50, Appendix J, Option B for Type B & C Testing
ML022120477
Person / Time
Site: McGuire, Mcguire  
(NPF-009, NPF-017)
Issue date: 07/22/2002
From: Barron H
Duke Energy Corp
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
TAC MB3565, TAC MB3566
Download: ML022120477 (10)


Text

P Duke w Energy.

Duke Energy Corporation McGuire Nuclear Station 12700 Hagers Ferry Road Huntersville, NC 28078-9340 (704) 875-4800 OFFIcýE (704) 875-4809 FA H. B. Barron Vice President July 22, 2002 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555

Subject:

Reference:

Duke Energy Corporation McGuire Nuclear Station, Units 1 and 2 Docket Numbers 50-369 and 50-370 Technical Specifications Amendment Request for Additional Information (RAI)

Implementation of 10 CFR 50, Appendix J, Option B for Type B and C Testing Letter from Mr.

H.B. Barron to NRC dated December 7, 2001 (MB3565 and MB3566)

This letter provides additional information that was requested by the NRC staff on June 24, 2002.

Attached you will find the excel spreadsheets which contain the ten year historical data for the McGuire penetration leakage rate testing of the containment purge valves associated with the recent License Amendment Request (LAR).

The only significant leakage in the last four and a half years has been during the outage after stroking the valves.

In these cases the leakage tests are not really surveillance tests, but are functional verifications that the valves are sealed before relying on them for containment isolation during the next fuel cycle.

A new T-ring design implemented for all containment purge valves over several outages has resolved the chronic leakage problems.

After implementing the modifications, acceptable valve leakage has been maintained during the following successive cycle until valves are again stroked

U.S. Nuclear Regulatory Commission July 22. 2002 Page 2 in the next outage.

The most recent non-outage leakage test failure (Unit 1, 1/29/98) was caused by gasket sealant dripping down onto the valve disc seating surfaces causing non-uniform deformation of the T-ring to seat seal.

After diagnosing and resolving the issue, this problem has not recurred.

Leakage testing results of these containment purge valves for the last three cycles has demonstrated acceptable performance.

These valves are maintained closed during modes 1 to 4 with power removed and no benefits are realized from on-line leakage testing.

Therefore, it is only necessary to perform leakage testing of the containment purge valves during the refueling outages as requested in the LAR.

If you have any questions with respect to this matter, please call Norman T.

Simms of Regulatory Compliance at 704-875-4685.

Sincerely yours, H.B. Barron Attachments

U.S. Nuclear Regulatory Commission July 22, 2002 Page 3 AFFIDAVIT H.B. Barron, being duly sworn, states that he is Vice President of Duke Energy Corporation; that he is authorized on the part of said corporation to sign and file with the Nuclear Regulatory Commission these amendments to the McGuire Nuclear Station Facility Operating Licenses Nos.

NPR-9 and NPF-17 and associated Technical Specifications; and that all statements and matters set forth within this submittal dated July 22, 2002 are true and correct to the best of his knowledge.

H.B. Barron, Vice President Subscribed and sworn to me:

Date

/Ak0-,t, e.bFk-a 94.-

i) 4y cmiso.

exapi My commission expires:

Notary Public 4/6/U. 1 0 0I SEAL

U.S. Nuclear Regulatory Commission July 22, 2002 Page 4 xc w/attachments:

L.A. Reyes U.S. Nuclear Regulatory Commission Regional Administrator, Region II Atlanta Federal Center 61 Forsyth St.,

SW, Suite 23T85

Atlanta, GA 30303 R.E. Martin (addressee only)

NRC Project Manager (MNS)

U.S. Nuclear Regulatory Commission One White Flint North, Mail Stop 0-8 G9 11555 Rockville Pike Rockville, MD 20852-2738 S.M. Shaeffer NRC Senior Resident Inspector McGuire Nuclear Station M. Frye Division of Radiation Protection 3825 Barrett Drive

Raleigh, NC 27609-7221

U.S. Nuclear Regulatory Commission July 22, 2002 Page 5 bxc w/attachments:

C.J. Thomas E.L. Hyland N.T.

Simms K.L. Crane R.L. Gill McGuire Master File # 1.3.2.9 Elliott

EI

McGuire Unit 1 Containment Purge Valve Penetration Leakage History p,#- /e

Penetration 1M-119 1M-138 1M-213 1M-357 1M-367 1M-368 1M-454 1M-455 1M-456 Inside CIV 1VP-15A 1VP-19A 1VP-17A 1VP-7A 1VP-2A 1VP-10A 1VP-4A 1VP-12A 1VP-9A Outside CIV 1VP-16B 1VP-20B 1VP-18B 1VP-6B 1VP-1B 1VP-11B 1VP-3B 1BP-13B 1VP-8B 4/25/2002 6

38 2

2 2

2 2

2 2

1/31/2002 3.7 7.3 8.1 21 35 86 28 62 6.4 11/8/2001 28 2

2 38 2

2 2

2 10 8/16/2001 2

29 2

6.5 2

5 2

2 4.5 5/24/2001 55 45 2

2 38 88 23 2

18 4/12/2001#

n/a 2 n/a n/a 3 n/a n/a n/a n/a 4/12/2001 #

2 1185 8.5 2 offscale 59 2

133 80.5 12/7/2000 5.3 34 2

2 4

2 2

2 4.8 9/10/2000 2

2 2

2 2

2 2

2 2

6/22/2000 5

34 2

45.8 2

10.8 4.2 16 2

3/30/2000 2.8 6

11.2 7.2 11 25 5.5 2

2.5 1/6/2000 9

35 2

4.6 4

36 7.2 8.5 2

11/1/1999#

n/a 13 6.6 n/a 2 n/a n/a 154 n/a 10/30/1999#

2 236 900 2 offscale 2

2 offscale 2

10/19/1999# n/a n/a 80 n/a n/a n/a n/a n/a n/a 7/22/1999 23.7 5.7 8.3 79 7.1 49 4.9 2.5 270 4/29/1999 5.5 2.9 5

38.3 2

2 2

41.2 320 2/4/1999 4.1 8.7 4.4 35.2 3.1 40.1 24.8 2

250 11/12/1998 2

2 2

2 22 2

2 11.5 250 8/20/1998 22.1 12.6 6.4 57.6 17.8 31.6 67.8 56.2 89.6 6/27/1998#

67.4 n/a n/a n/a n/a n/a n/a n/a 129.6 6/24/1998#

n/a 25 2

14 17 40 20 31 650 5/28/1998 2

7 8.8 50.3 2

2 2

47.5 2

3/5/1998 2

14 2

29 2

69 56 48 147 2/5/1998 n/a n/a n/a n/a n/a n/a n/a n/a 110 2/5/1998 n/a n/a n/a n/a n/a n/a n/a n/a 96 2/2/1998 n/a n/a n/a n/a n/a n/a n/a n/a 109.5 1/31/1998 n/a n/a n/a n/a n/a n/a n/a n/a 2250 1/30/1998 n/a n/a n/a n/a n/a n/a n/a n/a 4350 1/29/1998 n/a n/a n/a n/a n/a n/a n/a n/a 96 1/29/1998 n/a n/a n/a n/a n/a n/a n/a n/a 3400 1/29/1998 9.4 2

2 37 42 6.4 34.5 34 offscale 11/8/11997 n/a n/a n/a n/a n/a n/a n/a n/a 2

11/6/1997 n/a n/a n/a n/a n/a n/a n/a n/a 3500 10/30/1997 2

13.6 5

6.7 2

6.2 15.8 4.8 490 8/7/1997 76 120 12 87 27 2

47 2

2 5/13/1997#

75 71 74 34.6 49.9 32 137 44 81 5/8/1997#

n/a n/a n/a n/a n/a 2 n/a n/a 6

5/7/1997#

n/a n/a n/a n/a n/a 550 175 n/a n/a 5/6/1997#

n/a 10.5 n/a 9.4 n/a 508 offscale n/a offscale 5/6/1997#

41.5 304 24.8 265 116.5 415 offscale 26.8 offscale 5/1/1997#

95.4 n/a n/a n/a n/a n/a n/a n/a n/a 5/1/1997#

368.6 n/a n/a n/a n/a n/a n/a n/a n/a 4/29/1997#

offscale n/a n/a n/a n/a n/a n/a n/a n/a

McGuire Unit 1 Containment Purge Valve Penetration Leakage History V

Penetration 1M-119 1M-138 1M-213 1 M-357 1M-367 1M-368 1M-454 1M-455 1M-456 Inside CIV 1VP-15A 1VP-19A 1VP-17A 1VP-7A 1VP-2A 1VP-10A 1VP-4A 1VP-12A 1VP-9A Outside CIV 1VP-16B 1VP-20B 1VP-18B 1VP-6B 1VP-1B 1VP-11B 1VP-3B 1BP-13B 1VP-8B 3/25/1997#

n/a n/a n/a 50, n/a n/a n/a n/a n/a 3/11/1997#

n/a n/a n/a n/a n/a n/a 2 n/a n/a 2/27/1997#

n/a n/a n/a n/a n/a n/a 50 n/a n/a 2/25/1997 n/a n/a n/a n/a 850 n/a n/a n/a n/a 1/23/1997 5.4 2

2.2 6.3 2

59 7.8 2

6 10/24/1996 13.6 2

4.5 6.5 2

3 4.2 2.8 45.3 7/31/1996 91 12 64 17 42 102 137 53 53 4/9/1996 7.7 14.4 29 73.7 6.4 104.6 7.6 25.8 30.7 1/16/1996#

110.6 788 9.3 86 49.1 145 2

114 7.3 9/12/1995 37 21.3 11.6 28 15.3 26.5 7

33.6 2

6/20/1995 32 2

2 22 46 2

4 2

27.6 3/28/1995 2

2 2

2 2

2 2

2 2.6 12/27/1994 2

2 8.2 2

6.8 2

14.8 24.4 2

10/1/1994#

n/a n/a n/a n/a n/a 30 n/a n/a n/a 9/28/1994#

n/a n/a n/a n/a 2.4 offscale n/a n/a n/a 9/27/1994#

n/a n/a n/a n/a n/a n/a 2 n/a n/a 9/26/1994#

71.8 2

2 33.9 n/a offscale 258 46 2

5/17/1994 13.5 2

32.5 3

2 42.7 2

9.8 2

2/17/1994 n/a 920 n/a 18 47.5 n/a n/a 708 43 2/17/1994 48 offscale 24.2 125.2 offscale 42.8 60.6 1180 offscale 1/4/1994 36.8 7.5 4.3 3.5 26 60 2

44 83.5 10/15/1993 n/a n/a n/a 265 15 30.2 157 n/a 18.2 10/15/1993 10 32 9.5 1900 offscale offscale offscale 208 offscale 9/23/1993 n/a n/a n/a n/a 8.2 30.1 5.1 n/a n/a 9/23/1993 27.2 18 29 15 offscale offscale offscale 10 130 5/27/1993#

n/a n/a n/a n/a 18.2 30 n/a n/a n/a 5/26/1993#

51.2 8.8 3.8 23.6 offscale offscale 2

2 8.4 2/23/1993 30.2 78.1 2

45.7 2

36.2 5.2 8.6 5.1 12/1/1992 5.4 70 2

3.1 5.3 7.5 2

12.8 3.8 9/1/1992 2

2 2

2 2

2 41.5 2

20.5 6/12/1992 n/a n/a n/a n/a 22.2 36.8 n/a n/a n/a 6/11/1992 5.5 181.5 7.3 113 offscale offscale 27.8 2

6 2/15/1992 n/a 155 n/a n/a n/a 37.9 n/a n/a 232 2/13/1992 37.5 330 8.4 25.6 130 offscale 30.2 60.1 offscale Leakage is in sccm (standard cubic centimeters per minute). Lowest measurable leakage is 2 sccm "Offscale" means the volumetric leak rate test instrument makeup was unable to establish full test pressure

  1. Refueling Outage

McGuire Unit 2 Containment Purge Valve Penetration Leakage History Penetration 2M-1 19 2M-1 38 2M-213 2M-357 2M-367 2M-368 2M-454 2M-455 2M-456 Inside CIV 2VP-15A 2VP-19A 2VP-17A 2VP-7A 2VP-2A 2VP-1OA 2VP-4A 2VP-12A 2VP-9A Outside CIV 2VP-16B 2VP-20B 2VP-18B 2VP-6B 2VP-1B 2VP-11B 2VP-3B 1BP-13B 2VP-8B 6/12/2002 36.2 2

2 2

2 2

31.2 36.1 6.4 3/14/2002#

2 2

2 2

3 24 2

2 10 12/19/2001 38 2

2 25 49 36 2

2 10 10/3/2001 46.5 2

2 2

30 34 37 88.5 2

7/11/2001 35 2

16 36 65 72 19 97 26 4/18/2001 21 2

2 2

3 2

2 2

4.5 1/24/2001 14.5 2

6.9 10.3 15.5 9.2 3.7 2

4.5 11/1/2000 50.2 2

5.9 9.9 2

10.5 44.6 23.8 7.8 10/7/2000#

n/a 2 n/a n/a n/a n/a 2 n/a n/a 10/6/2000#

n/a offscale n/a n/a n/a n/a offscale n/a 2

10/5/2000#

12.8 offscale 76.3 9.2 4.8 8.5 offscale 2 offscale 8/9/2000 40 2

36 2

29 2

52.5 2

61 5/17/2000 39 2

2.8 2

29 2

161 31 39 2/23/2000 20 2

25 12 80 85 174 37.5 130 12/1/1999 4

2 4.3 5.3 6.6 11.9 119 33.5 94.2 9/8/1999 59 2

2 2

2 11.3 95 2

2 6/16/1999 41 2

5.4 29.1 70.1 46.4 174 4.5 7.3 4/10/1999#

148.9 3.2 93 142.5 56 47.2 143.1 133.7 73.7 4/6/1999#

73.3 offscale offscale 54.5 46.6 2 offscale 2 offscale 12/30/1998 48 2

2.5 40 25.6 10.8 13.4 32.4 2

10/7/1998 45.7 2

2 2

31.5 2

179 36 4

7/15/1998 29.3 2

3.1 34 12.5 8.3 166.3 88.1 37.6 5/5/1998 n/a n/a 8.4 n/a n/a n/a n/a n/a n/a 4/22/1998 50.6 13.6 15.6 28.1 14.1 36.4 110 29.2 81.6 1/28/1998 114 2

27 148 2.4 2

172.2 48.1 2

12/16/1997#

10 n/a n/a 84 20 n/a n/a n/a n/a 12/12/1997# n/a n/a n/a n/a n/a n/a n/a 2 n/a 12/12/1997#

59 5.6 30 61 47 11.4 130 offscale 49 12/3/1997#

n/a 32 57 n/a n/a n/a n/a n/a n/a 11/21/1997# n/a n/a n/a n/a 165 n/a n/a n/a n/a 11/18/1997# n/a n/a n/a n/a n/a n/a n/a n/a 2

10/22/1997#

2 n/a n/a n/a n/a n/a n/a n/a n/a 10/21/1997# n/a n/a n/a n/a n/a 135 n/a 150 n/a 10/13/1997# n/a n/a n/a n/a n/a n/a 533 n/a n/a 9/24/1997 61 25 17 25 2

2 40 77 2

8/13/1997 n/a n/a n/a n/a n/a n/a 45.5 55 n/a 6/25/1997 n/a n/a n/a n/a n/a 30.5 n/a 13.4 47.5 6/24/1997 6.1 4.1 10.8 2

2 offscale 2 offscale offscale 6/4/1997 n/a n/a n/a n/a n/a n/a 43 518 n/a 4/23/1997 2

2 2

2 44.5 2

88.6 550 2

3/12/1997 n/a n/a n/a n/a n/a n/a 31.5 522 n/a 1/29/1997 n/a n/a n/a n/a n/a n/a 30 n/a n/a 1/29/1997 50 26 50 76 2

58 8300 550 37

McGuire Unit 2 Containment Purge Valve Penetration Leakage History Penetration 2M-1 19 2M-138 2M-213 2M-357 2M-367 2M-368 2M-454 2M-455 2M-456 Inside CIV 2VP-15A 2VP-19A 2VP-17A 2VP-7A 2VP-2A 2VP-10A 2VP-4A 2VP-12A 2VP-9A Outside CIV 2VP-1 6B 2VP-20B 2VP-1 8B 2VP-6B 2VP-1 B 2VP-1 1 B 2VP-3B 1BP-13B 2VP-8B 10/30/1996 80 20 2

46 56 2

80 430 24 8/7/1996 50 23.5 14 2

49.5 50.5 5

2 39.2 5/9/1996#

n/a n/a n/a n/a 2 n/a n/a n/a n/a 5/8/1996#

n/a n/a n/a n/a n/a 2

77 100 30 5f7/1996#

152.2 18.6 18.1 15.1 2 offscale offscale offscale 417 4/3/1996 n/a n/a n/a n/a 56 n/a n/a n/a n/a 12/27/1995 47.3 13.5 12.3 2

675 30.7 34.8 12.5 39.4 10/4/1995 30.1 11.4 11.8 40.1 62.4 5.7 37.1 2

31.5 7/12/1995 43 2

2 33 55 4.5 20.6 2

2 4/5/1995 2

2 2

2 2

2 39 2

39.5 1/2/1995#

42.5 3.7 34.5 2

7.8 38.5 4.5 92 276 10/19/1994 2

29 36 2

146 35 22 27 1323*

7/20/1994 n/a n/a n/a n/a n/a n/a n/a n/a 304 7/13/1994 2

14.8 18 8.5 43 9

31 6 n/a 4/13/1994 18 28 21 22 85 2

36 61 63 1/12/1994 n/a n/a n/a n/a n/a n/a n/a n/a 44 1/12/1994 3.2 10.8 14.6 8.4 390 3

127.3 2 offscale 10/12/1993 n/a n/a n/a 2

2 2 n/a 2

105.3 10/11/1993 41.7 27.8 25.4 offscale offscale offscale 134.7 offscale offscale 8/20/1993#

115 30 35 20 28.8 27.2 24.7 57 27.4 2/24/1993 13.9 4.4 7.5 2

2 51.9 10 44 65.1 12/9/1992 n/a n/a n/a n/a n/a n/a n/a n/a 2

12/2/1992 2

19 17 2

17 2

4 6 offscale 9/9/1992 10.1 9.6 10.5 55 43.5 10.5 39.2 2

5.9 6/20/1992 80 22 11 100 40.2 2

2 8.9 85.4 Leakage is in sccm (standard cubic centimeters per minute)

Lowest measurable leakage is 2 sccm "Offscale" means the volumetric leak rate test instrument makeup was unable to establish full test pressure

  • 10/19/94 test of 2VP-8B was snooped/verified not to be leaking.
  1. Refueling Outage