Text
From:
Peter Tam To:
INTernet:David.distel@exeloncorp.com; INTernet:John.Hufnagel@exeloncorp.com; internet:paul.czaya@exelon.com Date:
7/23/02 1:20PM
Subject:
Oyster Creek Snubber Relief Request (TAC No. MB4995)
John:
This is concerning your 4/26/02 relief request. Our reviewer, Arnold Lee, has the following comments. Please call me to set up a conference call to discuss these comments, including disposition of them.
This e-mail does not convey a formal NRC staff position and does not formally request information. Its sole purpose is to prepare you and others for a conference call.
On page 2 of the subject request -- in the third sentence of the second paragraph--- you stated that "The Oyster Creek ISI Program also requires VT-3 visual examinations of a sample of snubbers in accordance with Article IWF-2000 and Table IWF-2500-1, Examination Category F-A."
Discuss:
(1) The basis of the snubber samples selection for these VT-3 examinations; (2) Extent of the examinations performed for the snubbers, knowing that IWF-2000 and Table IWF-2500-1 are primarily for component supports, excluding snubbers (ref. IWF-1220).
Peter S. Tam, Senior Project Manager Project Directorate I-1 Division of Licensing Project Management Office of Nuclear Reactor Regulation e-mail: pst@nrc.gov Tel.: 301-415-1451 CC:
Arnold Lee Mail Envelope Properties (3D3D906A.B50 : 10 : 20510)
Subject:
Oyster Creek Snubber Relief Request (TAC No. MB4995)
Creation Date:
7/23/02 1:20PM From:
Peter Tam Created By:
PST@nrc.gov Recipients Action Date & Time David Transferred 07/23/02 01:20PM distel (INTernet:David.distel@exeloncorp.
John Transferred 07/23/02 01:20PM
Hufnagel (INTernet:John.Hufnagel@exelonco paul Transferred 07/23/02 01:20PM czaya (internet:paul.czaya@exelon.com) nrc.gov owf2_po.OWFN_DO Delivered 07/23/02 01:20PM AJL CC (Arnold Lee)
Opened 07/23/02 01:54PM Post Office Delivered Route David INTernet:exeloncorp.
com John INTernet:exeloncorp.
com paul internet:exeloncorp.c om owf2_po.OWFN_DO 07/23/02 01:20PM nrc.gov Files Size Date & Time MESSAGE 2270 07/23/02 01:20PM Options Auto Delete: