Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION 1

1 1

1 1

1 1

1 1

1 1

1 1

2 2

2 2

2 1

2 3

5 6

7 8

9 12 13 14 15 16 1

4 5

6 9

5.79 10.82 2.57 6.80 8.01 4.53 7.24

1. 96 9.13 3.49 10.60 0.78 0.78 4.10 4.77 5.17 0.55 0.08 12.63 0.00 4.04 5.33 5.58 4.25 4.13 4.58 5.55 7.16 8.16 8.10 7.82 7.29 5.49 4.17 3.32 2.48 2.17 0.00 7.89 0.00 1.17
1. 72 2.53 3.29 3.57 3.77 4.33 5.02 6.07 6.68 5.51 4.55 4.44 3.97
1. 51 0.00 2.55 0.33 2.69 2.67 12.40 2.92
1. 47 0.19 4.73 5.03 3.30 4.77 5.50 2.46 6.28 4.85 6.74 8.08 2.89 ONT ONT ONT ONT ONT ONT ONT TEA ONT ONT ONT SVI TWO 33 TEA TEA TEA 178 1 355 1 1

1 175 1 180 1 170 1 178 1 24 2

176 1 168 1 181 1 66 2

66 2

24 2

24 2

26 2

o P 3 TWO 15 2

VOL 112 31 o

30 26 24 29 28 25 26 25 26 27 28 29 35 35 34 33 30 o

27 o

21 25 25 28 26 24 24 26 26 24 25 28 28 24 26 o

P 1 SCI P 3 TWO 0 P 3 TWO 36 P 3 TWO 48 P 3 TWO 50 P 3 TWO 38 P 3 TWO 37 P 3 TWO 41 P 3 TWO 50 P 3 TWD 66 P 3 TWD 77 P 3 TWD 76 P 3 TWD 73 P 3 TWO 67 P 3 TWO 49 P 3 TWO 37 P 3 TWO 29 P 3 TWO 22 P 3 TWO 20 P 3 TWO 0 P 1 SCI P 3 TWO 0 P 3 TWO 13 P 3 TWO 19 P 3 TWO 28 P 3 TWO 36 P 3 TWO 39 P 3 TWO 41 P 3 TWO 47 P 3 TWO 55 P 3 TWO 66 P 3 TWO 73 P 3 TWO 60 P 3 TWO 50 P 3 TWO 48 P 3 TWO 43 P 3 TWO 16 P 3 TWO 0 2

TEA 20 140 P 24 2

25 2

186 1 22 2

33 2

76 2

25 2

22 2

31 2

162 1 164 1 22 2

173 1 177 1 176 1 174 1 3 TWO 4 TEA TEA ONT TEA TEA VOL TEA TEA TEA DNT DNT TEA DNT DNT ONT ONT 27 2

TEA LTE UTE LTE LTE LTE UTE UTE UTE LTE LTE UTE 014 014 UTE UTE UTE 010 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 011 UTE UTE 010 UTE UTE 014 UTE UTE UTE LTE LTE UTE UTE UTE LTE UTE UTE

+11. 51

-11.22

+9.60

+11. 56

+10.40

-11.16

-11. 55

-0.30

+10.42

+11. 60

-11.30

+0.85

+0.85

-0.21

-0.22

-0.23

+0.46

+1. 27

-0.40

-0.40

-0.40

-0.40

-0.40

-0.40

-0.40

-0.40

-0.40

-0.40

-0.40

-0.40

-0.40

-0.40

-0.40

-0.40

-0.40

-0.40

-0.40

-0.40

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.20

+0.00

-0.34

-0.20

+0.00

-0.43

-0.16

+0.68

-0.21

-0.19

-0.20

+12.24

+10.83

-0.19

-11.12

-11. 59

+9.44

-12.19

-0.23 TO+160.0 TO+168.9 TO+177.8 TO+186.7 TO+195.6 TO+204.4 TO+213.3 TO+222.2 TO+231.1 TO+240.0 TO+248.9 TO+257.8 TO+266.7 TO+275.6 TO+284.4 TO+293.3 TO+302.2 TO+311.1 TO+320.0 TO+43.9 TO+52.7 TO+61.5 TO+70.2 TO+79.0 TO+87.8 TO+96.6 TO+105.4 TO+114.1 T0+122.9 TO+131. 7 TO+140.5 TO+149.3 TO+158.0 T0+166.8 TO+175.6 TO+184.4 05/02/02 13:29:09 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG LTE LTE UTE UTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE UTE UTE 014 014 014 014 UTE UTE UTE UTE UTE UTE 010 010 014 014 UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE 011 011 UTE UTE UTE UTE 010 010 UTE UTE UTE UTE 014 014 UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE WAR CL CL/CS WAR 4107 4107 4107 4107 4107 4024 4024 2015 4107 4107 4024 4024 4024 2016 2015 2016 4024 4024 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2075 2075 2075 2075 2075 2075 2075 2075 2075 2075 2075 2075 2075 2075 2075 2075 2075 2075 2075 4077 2034 2075 4077 2034 2037 4024 2009 2009 2009 4107 4107 2010 4024 4024 4107 4107 2009 OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET Page 1 of 155 PROBE 460SI 460SI 460SI 460SI 460SI 460SI 460S1 460HR 460S1 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460SI 460HR 460HR 460SI 460HR 460HR 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS ~ MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION 2

2 2

2 2

2 2

2 2

2 2

2 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 11 12 13 15

16.

17 19 20 21 22 26 27 1

2 3

7 8

9 11 12 13 14 15 16 17 18 20 23 26 27 29 32 2.70 5.46 5.54 2.42 0.35 4.67

1. 85 4.19 3.26 4.13 1.24 4.05 3.99 0.75 4.11 0.37 0.38 1.37 6.19 5.83 0.00 1.10 0.63
1. 43 1.88 2.31 3.33 3.88 3.63 4.07 4.88 4.08 2.43
1. 83
1. 69 2.18 2.63 3.04 0.00 6.58 2.15 4.21 8.02 5.65 4.65
1. 91
11. 62 4.99 8.42 0.35 0.46 13.48 7.97
1. 99 7.55 5.66 5.66 2.86 4.35 0.32
1. 51 2.02 2.49 2.31 2.66 0.28 2.68 2.30 3.30 0.66 4.38 2.27 0.49 0.94
1. 36 26 25 25 24 123 20 18 27 23 22 131 24 21 83 42 97 o

24 182 29 o

23 35 33 31 30 30 31 31 31 29 28 29 45 30 24 27 27 o

28 2

TEA 2

TEA 2

TEA 2

TEA P 3 TWD 4 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA P 3 TWD 15 2

TEA 2

TEA P 3 TWD 9 2

TEA 2

VOL P 3 TWD 6 2

TEA 1

DNT P 1 SCI P 4 TWD 0 P 4 TWD 10 P 4 TWD 10 P 4 TWD 17 P 4 TWD 27 P 4 TWD 36 P 4 TWD 56 P 4 TWD 66 P 4 TWD 62 P 4 TWD 70 P 4 TWD 84 P 4 TWD 70 P 4 TWD 38 P 4 TWD 26 P 4 TWD 23 P 4 TWD 33 P 4 TWD 42 P 4 TWD 50 P 4 TWD 0 2

TEA 2

TEA 24 193 P 179 1 181 1 180 1 22 2

174 1 179 1 176 1 81 2

o P

3 DNT DNT DNT DNT TEA DNT DNT DNT VOL 3 TWD 13 DNT DNT TEA DNT SAl TWD 91 DNT DNT VOL TEA TEA TEA TEA TEA 3

1 183 1 18 2

180 1 27 2

27 2

178 1 188 1 55 2

22 2

23 2

27 2

25 2

27 2

154 20 P 3 TWD 3 2

TEA 24 23 136 24 25 129 123 127 2

TEA 2

TEA P 3 TWD 8 2

TEA 2

TEA P 3 TWD 6 P 3TWD 11 P 3 TWD 16 UTE UTE UTE UTE 010 UTE UTE UTE UTE UTE 010 UTE UTE 010 UTE 014 015 UTE 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 UTE LTE LTE UTE LTE LTE LTE 003 003 UTE UTE UTE LTS UTE UTE UTE UTE 014 UTE UTE UTE UTE UTE 011 UTE UTE UTE 010 UTE UTE 010 010 009

-0.17

-0.21

-0.20

-0.28

+0.66

-0.21

-0.21

-0.20

-0.25

-0.23

-0.46

-0.23

-0.19

+0.51

-0.32

+1. 57

-0.88

-0.19

+0.38

-0.11

-0.11

-0.11

-0.11

-0.11

-0.11

-0.11

-0.11

-0.11

-0.11

-0.11

-0.11

-0.11

-0.11

-0.11

-0.11

-0.11

-0.11

-0.11

-0.11

-0.20

-0.20

+0.44

-12.00

+11. 97

+12.55

-0.18

+10.08

+11.40

+12.37

+0.89

+0.75

-11. 31

-11.79

-0.20

-13.92

-0.27

-0.27

-11.61

-11.10

+0.75

-0.18

-0.21

-0.21

-0.21

-0.18

-0.51

-0.21

-0.26

-0.20

-0.64

-0.21

-0.21

-0.48

-0.66

+0.23 TO+115.6 TO+124.4 TO+133.3 TO+142.2 TO+151.1 TO+160.0 TO+168.9 TO+177.8 TO+186.7 TO+195.6 TO+204.4 TO+213.3 TO+222.2 TO+231.1 TO+240.0 TO+248.9 TO+257.8 TO+266.7 TO+275.7 05/02/02 13:29:09 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE UTE UTE UTE UTE 010 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 010 UTE UTE UTE UTE 010 010 UTE UTE 014 014 015 015 UTE UTE 014 014 UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE UTE UTE 010 010 UTE UTE LTE LTE LTE LTE UTE UTE LTE LTE LTE LTE LTE LTE 003 003 003 003 UTE UTE UTE UTE UTE UTE LTS LTS UTE UTE UTE UTE UTE UTE UTE UTE 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 011 011 UTE UTE UTE UTE UTE UTE 010 010 UTE UTE UTE UTE 010 010 010 010 009 009 WAR WAR WAR WAR CL WAR CL/CS WAR WAR WAR WAR WAR 2010 2009 2010 2033 4077 2033 2034 2033 2033 2034 4077 2033 2075 4077 2034 4107 4024 2010 4107 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2010 4024 4107 4024 4024 2009 4024 4024 4024 4024 4024 4024 4024 2009 4107 2010 2010 4024 4024 4024 2009 2010 2009 2010 2009 4077 2033 2033 2034 4077 2033 2034 4077 4077 4077 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 2 of 155 PROBE 460HR 460HR 460HR 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460HR 460S1 460HR 460S1 460S1 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460S1 460S1 460S1 460HR 460SI 460S1 460S1 460SI 460S1 460S1 460S1 460HR 460S1 460HR 460HR 460S1 460S1 460S1 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460HR 460HR 460SI 460HR 460HR 460S1 460S1 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 3

3 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

33 34 1

2 3

7 8

9 10 11 12 13 14 16 18 19 20 21 22 23 24 26 27 28 29 32 37 38 2

3 6

9 10 11 12 13 14 15 16 17 18 20 21 22 23 25 28 0.98 1.32 1.13 3.05 0.15 2.58

1. 94 3.03 0.19 9.99 4.74 12.50 3.22 4.28 6.66 5.61 3.17 0.23 0.20 6.49 14.01
1. 89 2.09
11. 45
11. 51 0.61 3.91
1. 21
1. 99 2.93 3.50 5.48 0.44 3.12 0.45 3.03 0.54 5.34 3.67 3.42 0.34
1. 79 0.25
1. 36 7.38 9.59 3.28 3.92 2.22 0.17 3.65 3.19
1. 91
1. 47 2.35 16.67 15.82
1. 99 2.68 0.34 4.03 3.01 2.28
1. 93 0.83 2.75 3.93 5.11 3.44 0.41 4.07 2.96 8.31 7.83 5.14 116 P 3 TWO 12 010 136 P 3 TWO 16 010 132 ~ 3 TWO 13 010 27 2

TEA UTE 94 2

VOL 006 19 2

TEA UTE 33 2

TEA UTE 25 2

TEA UTE 53 2

VOL 001 175 1 ONT 010 26 2

TEA UTE 182 1 ONT 010 21 P 1 TEA UTE 24 2

TEA UTE 184 1 ONT 010 28 2

TEA UTE 24 2

TEA UTE 68 2

VOL 010 100 2 VOL 010 175 1 ONT LTS 179 1 ONT UTE 17 2

TEA UTE 23 2

TEA UTE 183 1 ONT LTS 174 1 DNT UTE o

P 3 TWO 16 010 24 2

TEA UTE 25 2

TEA UTE 23 2

TEA UTE 22 2

TEA UTE 22 2

TEA UTE 26 2

TEA UTE 117 P 3 TWO 5 009 23 2

TEA UTE 105 P 3 TWO 5 009 23 2

TEA UTE 107 P 3 TWO 6 009 26 2

TEA UTE 26 2

TEA UTE 25 2

TEA UTE 154 P 3 TWO 4 014 25 2

TEA UTE 93 2

VOL 010 140 P 3 TWO 16 010 176 1 ONT UTE 177 1 ONT LTE 23 2

TEA UTE 17 2

TEA UTE 22 2

TEA UTE 80 2

VOL 014 20 2

TEA UTE 196 1 ONT UTE 201 1 ONT UTE 16 2

TEA UTE 18 2

TEA UTE 183 1 ONT 010 180 1 ONT 010 24 2

TEA UTE 24 2

TEA UTE 31 2

VOL 014 25 2

TEA UTE 20 2

TEA UTE 24 2

TEA UTE 24 2

TEA UTE o

P 3 TWO 13 010 30 2

TEA UTE 26 2

TEA UTE 28 2

TEA UTE 29 2

TEA UTE o

P 3 TWO 7 009 28 2

TEA UTE 21 2

TEA UTE 162 1 ONT UTE 164 1 ONT LTE 23 2

TEA UTE

+0.57

-0.04

-0.42

-0.23

+1.12

-0.19

-0.17

-0.32

+1.29

-0.39

-0.24

-0.34

-0.18

-0.21

-0.60

-0.17

-0.20

+4.78

+5.26

-11. 02

-10.67

-0.20

-0.17

-11. 69

-11.64

-0.67

-0.20

-0.19

-0.20

-0.22

-0.23

-0.19

+0.68

-0.23

-0.65

-0.22

-0.40

-0.21

-0.23

-0.23

+0.54

-0.24

+0.98

-0.45

-8.50

+8.65

-0.24

-0.17

-0.25

+1.13

-0.18

-10.65

-11. 37

-0.17

-0.18

-0.24

-0.45

-0.16

-0.21

+0.89

-0.16

-0.17

-0.16

-0.21

-0.57

-0.14

-0.22

-0.19

-0.20

+0.60

-0.19

-0.18

-11. 33

+11.41

-0.22 05/02/02 13:29:09 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG 010 010 WAR 010 010 WAR 010 010 WAR UTE UTE 006 006 UTE UTE UTE UTE UTE UTE 001 001 010 010 UTE UTE 010 010 UTE UTE UTE UTE 010 010 UTE UTE UTE UTE 010 010 010 010 LTS LTS UTE UTE UTE UTE UTE UTE LTS LTS UTE UTE 010 010 WAR UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 009 WAR UTE UTE 009 009 WAR UTE UTE 009 009 WAR UTE UTE UTE UTE UTE UTE 014 014 WAR UTE UTE 010 010 010 010 WAR UTE UTE LTE LTE UTE UTE UTE UTE UTE UTE 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 010 010 010 UTE UTE UTE UTE 014 014 UTE UTE UTE UTE UTE UTE UTE UTE 010 010 WAR UTE UTE UTE UTE UTE UTE UTE UTE 009 009 WAR UTE UTE UTE UTE UTE UTE LTE LTE UTE UTE 4077 4077 4077 2075 4077 2079 2009 2010 4024 4024 2010 4024 2009 2010 4024 2009 2010 4024 4024 4107 4024 2009 2010 4024 4024 4024 2009 2009 2009 2010 2033 2033 4077 2034 4077 2033 4077 2033 2034 2033 4077 2033 4077 4077 4077 4077 2034 2009 2010 4024 2009 4107 4107 2009 2010 4024 4024 2009 2010 4024 2009 2010 2009 2010 4024 2009 2010 2009 2010 4024 2009 2010 4077 4077 2033 INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET INLET INLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET OUTLET OUTLET INLET INLET OUTLET OUTLET INLET INLET OUTLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET Page 3 of 155 PROBE 460SI 460SI 460SI 460HR 460SI 460HR 460HR 460HR 460SI 460SI 460HR 460SI 460HR 460HR 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460SI 460HR 460SI 460HR 460HR 460HR 460SI 460HR 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460SI 460HR 460SI 460SI 460HR 460HR 460SI 460SI 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460SI 460S1 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LI8T OF IMPERFECTION8 ~ MRPC/PLU8 POINT QUERY: QueryM1 ROW TUBE VOLT8 OEG CHN INO %TW LOCATION 5

5 5

5 5

5 5

5 5

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

29 30 31 32 34 36 37 42 45 1

2 3

5 6

8 12 13 15 17 18 20 21 22 23 24 25 27 4.36 6.11 0.39 2.06 7.58 0.34 5.73 3.24 0.51 0.43 4.22 0.10 0.14 5.03 0.61 0.63 0.66 0.57 0.35 0.62 0.72 6.36 5.30 2.26 0.47 3.37 5.48 2.91 5.75 4.63 2.74

1. 14
1. 50 0.00 0.31 0.90 1.92
1. 79
1. 58 1.72
1. 73 0.00 2.81 2.67 0.45 0.42 14.41 0.11 2.80 8.78 8.92 3.32 0.19 4.86 0.19 3.06 0.20 3.25 0.11 3.90 3.86 2.56 0.35 0.93 0.00 0.63
1. 02
1. 01 0.70 0.24 0.00 0.69 4.47 3.24 7.72 ONT ONT 187 1 354 1 31 P 3 TWO 7 2

TEA 17 178 145 171 29 50 39 27 98 94 351 109 126 71 65 126 89 1

DNT P 3 TWO 6 1

ONT 2

TEA P 3 TWO 10 P 3 TWD 9 2

TEA 2

VOL 2

VOL 1

ONT P 3 TWO 10 P 3 TWO 11 P 3 TWO 11 2

VOL P 3 TWO 6 P 3 TWO 10 P 3 TWO 12 1

ONT 74 341 340 26 119P 18 2

177 1 182 1 182 1 185 1 16 2

17 1

ONT 2

TEA 2

3 TWO 11 TEA ONT ONT ONT ONT TEA TEA 31 o

35 9

12 14 11 15 17 o

29 14 45 o

181 71 19 182 187 23 111 26 o

19 97 25 64 26 25 21 88 18 o

22 14 16 17 31 o o 24 21 P 1 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 2

2 2

SCI TWO 0 3

15 54 47 37 43 44 o

TWO TWO TWO TWO TWO TWO TWO TWO TEA TEA VOL P 3 TWO 12 1

ONT 2

VOL 2

TEA 1

ONT 1

ONT 2

TEA P 3 TWO 3 2

TEA P 3 TWO 4 2

TEA P 3 TWO 4 2

TEA 2

VOL 2

TEA 2

TEA 2

TEA P 3 TWO 7 P 1 SCI P 3 TWO 0 P 3 TWO 33 P 3 TWO 55 P 3 TWO 55 P 3 TWO 37 P 3 TWO 13 P 3 TWO 0 P 3 TWO 11 2

TEA 2

TEA 175 1 ONT LTE UTE 006 UTE UTE 009 LTE UTE 009 009 UTE 014 014 013 011 009 009 012 009 009 009 UTE LTE UTE 010 UTE LTE 010 UTE 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 013 014 010 014 UTE 010 010 UTE 014 UTE 009 UTE 013 UTE 014 UTE UTE UTE 009 UTE UTE UTE UTE UTE UTE UTE UTE 009 UTE UTE LTE

+9.96

-11.16

-0.63

-0.22

-11. 52

-0.65

+9.99

-0.24

-0.76

+0.60

-0.29

+1.09

+1.39

-6.53

-0.66

+0.74

+0.69

+0.74

+0.62

+0.24

+0.65

-8.54

+7.29

-0.31

+0.69

-0.20

+10.06

-0.61

-9.40

-0.51

-0.18

-0.19

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.18

-0.17

-0.77

+0.77

-0.30

+0.99

-0.16

-0.51

+0.35

-0.23

+0.67

-0.18

-0.01

-0.18

+0.72

-0.19

+1. 57

-0.16

-0.27

-0.21

+0.57

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

+0.39

-0.20

-0.17

+11.42 TO+22.5 TO+31. 5 TO+40.5 TO+49.5 TO+58.5 TO+67.5 TO+76.5 TO+85.5 TO+94.5 TO+238.5 TO+247.5 TOt256.5 TO+265.5 TO+274.5 TO+283.5 TO+292.5 05/02/02 13:29:09 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG LTE LTE UTE UTE 006 006 UTE UTE UTE UTE 009 009 LTE LTE UTE UTE 009 009 009 009 UTE UTE 014 014 014 014 013 013 011 011 009 009 009 009 012 012 009 009 009 009 009 009 UTE UTE LTE LTE UTE UTE 010 010 UTE UTE LTE LTE 010 010 UTE UTE 010 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 013 013 014 014 010 010 014 014 UTE UTE 010 010 010 010 UTE UTE 014 014 UTE UTE 009 009 UTE UTE 013 013 UTE UTE 014 014 UTE UTE UTE UTE UTE UTE 009 009 UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS 009 009 UTE UTE UTE UTE LTE LTE WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR CL WAR WAR WAR WAR WAR CL WAR 4129 4081 4081 2034 4081 4081 4081 2075 4126 4126 2034 4081 4081 4081 4081 4081 4081 4081 4081 4081 4081 4081 4081 2033 4080 2034 4028 4028 4028 4028 2009 2010 2010 2010 2010 2010 2010 2010 2010 2010 2010 2010 2009 2010 4024 4024 4107 4107 2009 4107 4107 2010 4107 2009 4046 2009 4107 2010 4046 2009 2010 2009 4107 2010 2010 2010 2010 2010 2010 2010 2010 4024 2009 2010 4080 INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET INLET OUTLET INLET OUTLET INLET OUTLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET OUTLET Page 4 of 155 PROBE 46081 460SI 46081 460HR 46081 46081 460SI 460HR 52081 52081 460HR 4608I 460SI 46081 46081 460SI 460SI 460SI 460SI 460SI 46081 46081 46081 460HR 46081 460HR 46081 460SI 460SI 46081 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 46081 460SI 460SI 460HR 46081 46081 460HR 46081 460HR 46081 460HR 46081 460HR 46081 460HR 460HR 460HR 46081 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 46081 460HR 460HR 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION 6

6 6

6 6

6 6

6 6

6 6

6 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

31 32 33 36 37 38 39 40 44 46 48 50 1

3 4

5 8

9 10 13 14 15 16 17 18 20 21 22 23 24 25 26 28 0.71 6.33 2.88 7.06 4.02 4.16 5.06 10.60 15.71 9.53 5.02 3.80 0.31

1. 94 2.13 0.39 0.29 3.49 3.35 4.88 8.48 5.00 1.02 13.72 2.98 0.13 4.00 6.19 8.41 35.41 3.29 2.16 3.83 2.87 3.27 7.43 3.39 2.07 7.52 3.85
11. 91 3.21 8.21 2.12 0.35 9.21 4.38 1.72 2.91 0.24 8.21 2.02 0.36 3.03 3.97 3.10 0.26
1. 97 3.27 0.49 2.68 0.46 4.37 3.76 0.28 3.76 0.76 0.00 0.34 0.69 0.82 0.78 0.00
1. 36 4.87 3 TWD 17 DNT TEA DNT DNT DNT TEA SCI SCI DNT DNT TEA 104 P 162 1 21 2

178 1 169 1 180 1 27 2

19 1

29 1

183 1 179 1 31 2

59 P 3 TWD 7 2

TEA 20 18 74 60 184 181 176 174 176 18 187 21 2

TEA P 3 TWD 9 P 3 TWD 7 1

DNT 1

DNT 1

DNT 1

DNT 1

DNT 2

TEA 1

DNT 2

TEA 2

VOL 75 179 178 182 48 184 192 1 187 1 186 1 24 2

187 1 26 2

25 2

182 1 24 2

181 1 24 2

186 1 14 2

143 2 176 1 181 1 200 1 22 2

49 179 19 114 P 17 2

26 2

24 2

58 2

21 2

23 2

50 1

DNT 1

DNT 1

DNT 1

PVN 1

ONT ONT DNT ONT TEA ONT TEA TEA ONT TEA DNT TEA DNT TEA VOL DNT DNT DNT TEA P 3 TWO 10 1

DNT 2

TEA 3 TWO 7 TEA TEA TEA VOL TEA TEA P 3 TWD 19 2

TEA 30 67 25 27 36 29 26 o

71 61 50 48 o

o 27 P 3 TWO 18 2

TEA 2

TEA P 3 TWD 5 2

TEA P 1 SCI P 3 TWD 0 P 3 TWD 24 P 3 TWD 67 P 3 TWD 95 P 3 TWD 86 P 3 TWD 0 P 3 TWO 24 2

TEA 009 UTE UTE LTE LTE UTE UTE LTE LTE LTE UTE UTE 008 UTE UTE 008 008 LTE LTE LTE 009 UTE UTE 009 UTE 014 LTE 010 UTE LTE LTS LTS 010 UTE UTE 010 UTE UTE 010 UTE 010 UTE 010 UTE 009 010 UTE UTE UTE 007 010 UTE 010 UTE UTE UTE 009 UTE UTE 010 UTE 010 UTE UTE 013 UTE UTE UTE UTE UTE UTE UTE UTE 010 UTE

+0.36

-10.95

-0.21

+7.19

+9.94

-11.56

-0.24

+0.20

+1. 08

+9.97

-1l.66

-0.26

-0.67

-0.21

-0.23

+0.13

-0.18

+8.08

+10.13

+10.75

+0.23

-11.44

-0.16

+0.36

-0.26

+1. 42

+7.38

-0.25

-9.31

+1.12

-11.10

-6.20

-0.45

-9.79

-0.18

-0.27

-0.24

-0.17

-0.10

-0.22

-0.25

-0.18

-0.03

-0.19

-0.65

-0.61

-7.61

-8.55

-0.19

+0.61

-0.67

-0.22

-0.62

-0.26

-0.19

-0.19

+0.56

-0.23

-0.15

+0.03

-0.16

-0.01

-0.22

-0.17

+0.69

-0.21

-0.31

-0.31

-0.31

-0.31

-0.31

-0.31

-0.31

-0.73

-0.24 TO+85.5 TO+94.5 TO+103.5 TO+112.5 TO+121.5 TO+130.5 05/02/02 13:29:09 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG 009 009 UTE UTE UTE UTE LTE LTE LTE LTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE 008 008 UTE UTE UTE UTE 008 008 008 008 LTE LTE LTE LTE LTE LTE 009 009 UTE UTE UTE UTE 009 009 UTE UTE 014 014 LTE LTE 010 010 UTE UTE LTE LTE LTS LTS LTS LTS 010 010 UTE UTE UTE UTE 010 010 UTE UTE UTE UTE 010 010 UTE UTE 010 010 UTE UTE 010 010 UTE UTE 009 009 010 010 UTE UTE UTE UTE UTE UTE 007 007 010 010 UTE UTE 010 010 UTE UTE UTE UTE UTE UTE 009 009 UTE UTE UTE UTE 010 010 UTE UTE 010 010 UTE UTE UTE UTE 013 013 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 010 UTE UTE WAR WAR WAR WAR WAR WAR WAR WAR WAR CL WAR 4080 4080 2034 4080 4080 4080 2033 704 704 4080 4080 2033 4080 2033 2034 4080 4080 4129 4129 4129 4080 4080 2033 4080 2033 4080 4080 4080 4080 705 4028 4028 4028 4028 2009 4028 2010 2009 4028 2010 4107 2009 4028 2010 4107 4107 4107 4107 2009 4028 4107 2010 4107 2010 2009 2010 4028 2010 2009 4028 2009 4028 2010 2009 4028 2010 2010 2010 2010 2010 2010 2010 2010 4084 2033 OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET OUTLET INLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET INLET INLET INLET OUTLET INLET INLET OUTLET INLET OUTLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET Page 5 of 155 PROBE 460SI 460SI 460HR 460SI 460S1 460S1 460HR 380EX 380EX 460S1 460S1 460HR 460S1 460HR 460HR 460SI 460S1 460S1 460S1 460S1 460S1 460SI 460HR 460S1 460HR 460S1 460S1 460S1 460S1 380EX 460SI 460S1 460S1 460S1 460HR 460S1 460HR 460HR 460S1 460HR 460S1 460HR 460S1 460HR 460S1 460S1 460S1 460S1 460HR 460S1 460S1 460HR 460S1 460HR 460HR 460HR 460S1 460HR 460HR 460S1 460HR 460S1 460HR 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC!PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION 7

7 7

7 7

7 7

7 7

7 7

7 8

8 8

8 8

8 8

8 30 31 34 35 36 38 39 43 44 45 46 48 1

2 3

4 5

6 8

9 10.44 9.82 3.27 10.89 10.29 3.78 6.64 7.65 9.17 9.30 4.37 9.55 3.34 0.36 12.69 4.40 3.63 4.61 7.91 7.66 0.41 8.20 2.98 6.79 6.50 9.99 8.79 5.23 4.36 5.81 8.83 6.02

1. 55 6.59 4.46 0.36 0.13 0.10 5.63 3.56 0.45 6.78 6.04 2.09 0.00 0.76
1. 23 2.07
1. 43 0.85 0.00 4.90 3.58 3.53 5.16 5.66 9.02 8.11 2.58 0.00
1. 49 2.20 2.84 2.99 2.71
1. 88 0.00 6.74 3.70 2.91 0.71
11. 02 16.06 3.44
1. 61 DNT DNT TEA DNT DNT TEA DNT DNT DNT DNT TEA DNT TEA 3 TWD 9 DNT TEA TEA TEA DNT DNT 3 TWD 10 DNT TEA DNT DNT DNT DNT DNT DNT DNT DNT DNT TEA DNT DNT VOL VOL VOL DNT TEA 179 1 181 1 30 2

181 1 181 1 25 2

184 1 178 1 181 1 180 1 26 2

180 1 31 2

60 P

181 1 26 2

25 2

24 2

172 1 188 1 131 P 178 1 22 2

182 1 185 1 185 1 176 1 180 1 177 1 178 1 171 1 176 1 26 2

177 1 181 1 79 2

60 2

76 2

179 1 25 2

136 178 176 19 P 3 TWD 9 1

DNT o

20 19 18 16 29 o

177 166 27 172 173 177 181 16 o

28 22 20 20 16 7

o 356 28 21 1

DNT P 1 SCI P 4 TWD 0 P 4 TWD P 4 TWD P 4 TWD P 4 TWD 6

21 50 28 P 4 TWD 9 P 4 TWD 0 1

1 2

1 1

1 1

P 1 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 1

2 2

DNT DNT TEA DNT DNT DNT DNT SCI TWD 0 TWD 33 49 64 68 61 42 o

TWD TWD TWD TWD TWD TWD DNT TEA TEA 62 P

174 1 183 1 25 2

20 2

3 TWD 13 DNT DNT TEA TEA LTE UTE UTE LTE UTE UTE LTE LTE UTE UTE UTE 009 UTE 008 009 UTE UTE UTE LTE 009 010 UTE UTE LTE LTE 009 UTE LTE UTE LTE 009 UTE UTE LTE 009 014 014 014 UTE UTE 013 UTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE UTE LTE LTE 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 UTE UTE 009 010 010 UTE UTE

+11.45

-11.22

-0.26

+10.41

-11.22

-0.26

+7.21

+10.15

-11. 85

-8.21

-0.27

-0.07

-0.26

-0.70

+0.10

-0.22

-0.22

-0.23

+11. 53

+0.16

-0.74

-11.45

-0.22

+10.73

+11. 82

+0.35

-11.50

+10.50

-11. 34

+11. 03

+0.30

-10.90

-0.25

+10.58

+0.41

  • +0.82

+1.14

+1. 47

-10.74

-0.19

+0.74

-11.24

+10.63

-0.23

-0.23

-0.23

-0.23

-0.23

-0.23

-0.23

-0.23

-11.55

+10.59

-0.14

+10.95

+10.28

-0.51

-11. 55

-0.25

-0.25

-0.25

-0.25

-0.25

-0.25

-0.25

-0.25

-:0.25

-0.46

-0.17

-0.17

-0.62

-0.10

+0.22

-0.15

-0.19 TO+342.2 TO+351.1 TO+O.O TO+8.9 TO+17.8 TO+26.7 TO+35.6 TO+351. 1 TO+O.O TO+8.9 TO+17.8 TO+26.7 TO+35.6 TO+44.4 TO+53.3 05/02/02 13:29:10 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG LTE LTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE 009 009 UTE UTE 008 008 009 009 UTE UTE UTE UTE UTE UTE LTE LTE 009 009 010 010 UTE UTE UTE UTE LTE LTE LTE LTE 009 009 UTE UTE LTE LTE UTE UTE LTE LTE 009 009 UTE UTE UTE UTE LTE LTE 009 009 014 014 014 014 014 014 UTE UTE UTE UTE 013 013 UTE UTE LTE LTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE LTE LTE UTE UTE LTE LTE LTE LTE 010 010 UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS 010 010 UTE UTE UTE UTE 009 009 010 010 010 010 UTE UTE UTE UTE WAR WAR WAR CL CL WAR 4084 4084 2033 4084 4084 2034 4084 4084 4084 4084 2033 4080 2034 4080 4080 2033 2033 2034 4080 4080 4080 4080 2033 4080 4080 4080 4080 4080 4080 4080 4080 4080 2034 4080 4080 4080 4080 4080 4080 2033 4046 4107 4046 2009 2009 2009 2009 2009 2009 2009 2009 4107 4046 2009 4107 4107 4107 4107 2010 2010 2010 2010 2010 2010 2010 2010 2010 4046 2009 2010 4046 4046 4046 2009 2010 OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET OUTLET OUTLET OUTLET INLET INLET Page 6 of 155 PROBE 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460HR 460SI 460HR 460SI 460SI 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460HR 460S1 460S1 460S1 460S1 460S1 460S1 460SI 460SI 460S1 460HR 460SI 460S1 460SI 460SI 460SI 460S1 460HR 460S1 460S1 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460S1 460HR 460SI 460SI 460S1 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460SI 460SI 460S1 460HR 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 9

9 9

9 9

9 9

9 9

9 9

11 12 13 14 16 18 22 23 24 25 26 27 28 29 30 31 32 33 34 37 44 46 47 50 53 54 1

6 7

8 11 12 14 15 16 19 20 15.60 18.12 3.07 3.78 7.50

1. 92 0.40 5.86
1. 99 0.48 3.87 3.84
1. 09 0.19 2.12 0.17 0.54 4.06
1. 43 2.58 2.06 0.35 0.33 5.49 0.25 0.16 2.55 3.00 9.27 10.60
1. 75 10.13 5.21 6.12 9.01 5.68 12.51 8.53 2.17 6.69 10.71
1. 77
11. 95 8.40 6.43 14.37 17.41 11.60 4.45 8.70 10.16 6.77 6.20
1. 03 9.43 2.46 4.03 3.28 4.73 0.54 7.67 5.49 0.68 14.76
11. 63 3.38
1. 41 0.69 3.00 5.42 3.71 0.87 2.35 0.51 4.33 DNT DNT TEA DNT DNT TEA 182 1 4

1 22 2

181 1 184 1 25 2

152 181 21 P 3 TWD 16 1

DNT 2

TEA 77 22 28 16 101 24 122 94 32 25 25 23 o

o 28 o

100 25 22 183 184 20 178 177 175 180 26 180 180 20 177 175 34 174 175 169 179 177 176 23 180 179 183 180 49 176 25 22 22 176 48 178 22 P 3 TWD 19 2

TEA 2

TEA 2

TEA P 3 TWD 3 2

TEA P 3 TWD 7 P 3 TWD 20 2

TEA 2

TEA 2

TEA 2

TEA P 3 TWD 6 P 3 TWD 6 2

TEA P 3 TWD 5 2

VOL 2

TEA 2

TEA 1

DNT 1

DNT 2

TEA 1

DNT 1

DNT 1

DNT 1

DNT 2

TEA 1

DNT 1

DNT 2

TEA 1

DNT 1

DNT 2

TEA 1

DNT 1

DNT 1

DNT 1

DNT 1

DNT 1

DNT 2

TEA 1

DNT 1

DNT 1

DNT 1

DNT 2

TEA 1

DNT 2

TEA 2

TEA 2

TEA 1

DNT P 3 TWD 10 1

DNT 2

TEA 64 P

175 1 173 1 24 2

10 2

121 21 184 3 TWD 12 P 3 2

1 DNT DNT TEA TEA TWD 13 TEA DNT 22 103 24 72 24 2

P 3 2

P 3 2

TEA TWD 16 TEA TWD 10 TEA 010 010 UTE 010 010 UTE 009 010 UTE 010 UTE UTE UTE 010 UTE 009 009 UTE UTE UTE UTE 009 009 UTE 009 009 UTE UTE LTE UTE UTE LTE LTE LTE UTE UTE LTE UTE UTE LTE UTE UTE LTE UTE UTE LTE 009 010 UTE 010 LTE UTE UTE UTE 010 UTE UTE UTE 010 008 010 UTE 008 010 010 UTE UTE 007 UTE 010 UTE 010 UTE 010 UTE

+0.00

-0.04

-0.16

-0.51

-0.01

-0.19

+0.59

-0.39

-0.27

-0.62

-0.19

-0.19

-0.19

-0.52

-0.18

-0.49

-0.52

-0.17

-0.21

-0.16

-0.20

-0.65

-0.18

-0.40

-0.09

-0.36

-0.23

-0.22

+10.54

-11. 34

-0.26

+7.57

+10.32

+11. 01

-7.79

-0.12

+10.95

-11. 30

-0.16

+10.76

-11. 02

-0.21

+10.77

-11.12

-11.83

+10.85

+0.62

-0.56

-0.24

-0.47

+9.67

-11.24

-9.63

-0.30

+0.44

-0.21

-0.16

-0.23

-0.59

-0.71

-0.69

-0.18

-0.02

-0.03

-0.38

-0.21

-0.17

+0.62

-0.25

-0.52

-0.16

-0.74

-0.25

-0.71

-0.20 05/02/02 13:29:10 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG 010 010 010 010 UTE UTE 010 010 010 010 UTE UTE 009 009 WAR 010 010 UTE UTE 010 010 WAR UTE UTE UTE UTE UTE UTE 010 010 WAR UTE UTE 009 009 WAR 009 009 WAR UTE UTE UTE UTE UTE UTE UTE UTE 009 009 WAR 009 009 WAR UTE UTE 009 009 WAR 009 009 UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE LTE LTE 009 009 010 010 UTE UTE 010 010 LTE LTE UTE UTE UTE UTE UTE UTE 010 010 UTE UTE UTE UTE UTE UTE 010 010 008 008 WAR 010 010 UTE UTE 008 008 WAR 010 010 010 010 UTE UTE UTE UTE 007 007 WAR UTE UTE 010 010 UTE UTE 010 010 WAR UTE UTE 010 010 WAR UTE UTE 4046 4107 2009 4046 4028 2009 4028 4028 2010 4028 2009 2009 2010 4028 2009 4028 4028 2009 2010 2009 2010 4084 4084 2033 4084 4084 2075 2034 4084 4084 2033 4084 4084 4084 4084 2034 4084 4084 2034 4084 4084 2033 4084 4084 4126 4084 4084 4084 2033 4126 4084 4084 4084 2034 4046 2015 2009 2010 4046 4046 4046 2009 4046 4046 4048 2010 2009 4048 2010 4046 2009 4107 2010 4046 2009 OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET INLET INLET INLET OUTLET INLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET OUTLET INLET OUTLET INLET OUTLET INLET Page 7 of 155 PROBE 460SI 46081 460HR 46081 460SI 460HR 460SI 460SI 460HR 460SI 460HR 460HR 460HR 460SI 460HR 460SI 460SI 460HR 460HR 460HR 460HR 460SI 460SI 460HR 460SI 460SI 460HR 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460SI 520SI 460SI 460SI 460SI 460HR 520SI 460SI 460SI 460SI 460HR 460SI 460HR 460HR 460HR 460SI 460SI 460SI 460HR 460SI 460SI 46081 460HR 460HR 460SI 460HR 460SI 460HR 460SI 460HR 460S1 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 21 22 24 25 26 29 31 32 33 34 37 38 39 40 43 44 45 46 47 48 49 50 52 55 5

7 8

9 10 11 14 15 17 18 23 25 26 28 29 34 39 41 43 45 2.92 1.95 2.23 2.82 0.22 0.45 0.82 1.05 0.27 0.19 3.31 0.17 5.44 0.16 2.23 4.21 0.22 0.38 2.43 3.18 2.81 2.83 1.11

1. 04 8.79
11. 44 3.25 0.42 0.56 0.24 0.12 8.38 10.05
1. 83 0.44 0.48 8.80 9.39 7.88 9.17 14.62 6.95 4.36 2.82 8.24
1. 71 7.30 3.93 2.35 4.10 0.70 0.63 1.05 5.69 0.68 5.87 9.06 3.66 2.10 0.78
1. 02
1. 96 5.00 0.30 4.05 2.53 1.22 4.02 0.72 3.89 5.70 3.14 3.95 2.30 2.91 TEA TEA TEA TEA VOL 23 2

23 2

20 2

24 2

140 2 53 P 3 TWO 9 22 23 23 o

25 o

27 86 21 2

2 2

P 3 2

TEA TEA VOL TWO 4 TEA P 3 TWO 3 2

TEA VOL TEA 2

2 2

TEA 3 TWO 3 3 TWO 8 TEA TEA TEA TEA TEA TEA ONT ONT TEA 27 146 P o

P 24 2

23 2

22 2

27 2

12 2

92 2

180 1 178 1 22 2

48 P 3 TWO 9 P 3 TWO 12 2

VOL 64 75 89 179 176 20 o o 179 181 189 191 175 183 25 21 177 179 178 27 18 24 138 138 17 26 82 170 182 20 20 113 18 34 26 129 27 23 118 28 98 26 28 30 25 26 23 2

VOL 1

ONT 1

ONT 2

TEA P 3 TWO 9 P 3 TWO 10 1

ONT 1

ONT 1

ONT 1

ONT 1

ONT 1

ONT 2

TEA 2

TEA 1

ONT 1

DNT 1

ONT 2

TEA 2

TEA 2

TEA P 3 TWO 13 P 3 TWO 12 2

TEA 2

TEA P 3 TWO 13 1

ONT 1

ONT 2

TEA 2

TEA P 3 TWO 15 2

TEA 2

TEA 2

TEA P 3 TWO 6 2

TEA 2

TEA P 3 TWO 21 2

TEA P 3 TWO 13 2

TEA 2

2 2

2 2

TEA TEA TEA TEA TEA UTE UTE UTE UTE 007 010 UTE UTE 009 009 UTE 009 UTE 014 UTE UTE 007 009 UTE UTE UTE UTE UTE UTE LTE UTE UTE 007 007 014 014 LTE UTE UTE 009 009 LTE UTE 009 009 LTE UTE UTE UTE LTS LTS UTE UTE UTE UTE 010 010 UTE UTE 009 010 010 UTE UTE 010 UTE UTE UTE 007 UTE UTE 010 UTE 010 UTE UTE UTE UTE UTE UTE

-0.23

-0.18

-0.17

-0.17

+0.01

-0.75

-0.20

-0.19

-4.19

-0.73

-0.23

-0.63

-0.45

+1.16

-0.20

-0.19

-0.17

-0.77

-0.34

-0.25

-0.33

-0.17

-0.35

-0.17

+10.59

-11.11

-0.18

+0.65

-0.72

+0.75

+1. 21

+10.98

-11.05

-0.21

+0.50

-0.63

+10.57

-11. 24

+0.56

-0.19

+10.57

-10.84

-0.19

-0.08

-11. 59

-13.27

-10.66

-0.19

-0.20

-0.14

+0.52

-0.79

-0.21

-0.20

-0.66

-0.51

-0.44

-0.20

-0.21

-0.62

-0.22

-0.17

-0.15

+0.74

-0.15

-0.19

-0.60

-0.23

-0.52

-0.17

-0.25

-0.18

-0.20

-0.23

-0.34 05/02/02 13:29:10 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE UTE UTE UTE UTE 007 007 010 010 WAR UTE UTE UTE UTE 009 009 009 009 WAR UTE UTE 009 009 WAR UTE UTE 014 014 UTE UTE UTE UTE 007 007 WAR 009 009 WAR UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE 007 007 WAR 007 007 WAR 014 014 014 014 LTE LTE UTE UTE UTE UTE 009 009 WAR 009 009 WAR LTE LTE UTE UTE 009 009 009 009 LTE LTE UTE UTE UTE UTE UTE UTE LTS LTS LTS LTS UTE UTE UTE UTE UTE UTE UTE UTE 010 010 WAR 010 010 WAR UTE UTE UTE UTE 009 009 WAR 010 0]0 010 010 UTE UTE UTE UTE 010 010 WAR UTE UTE UTE UTE UTE UTE 007 007 WAR UTE UTE UTE UTE 010 010 WAR UTE UTE 010 010 WAR UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 2010 2009 2009 2010 4046 4046 2010 2010 4086 4086 2034 4084 2033 4084 2033 2034 4129 4084 2033 2034 2033 2034 2033 2034 4084 4084 2033 4126 4126 4126 4126 4084 4084 2034 4084 4084 4084 4084 4129 4129 4084 4084 2033 2034 4107 4107 4107 2009 2009 2009 4048 4048 2010 2009 4048 4048 4048 2009 2010 4048 2010 2009 2009 4046 2009 2010 4046 2010 4046 2009 2034 2034 2033 2033 2033 INLET INLET INLET INLET OUTLET OUTLET INLET INLET OUTLET OUTLET INLET OUTLET INLET OUTLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET INLET INLET OUTLET INLET INLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET INLET Page 8 of 155 PROBE 460HR 460HR 460HR 460HR 460SI 46031 460HR 460HR 46031 46031 460HR 46031 460HR 46031 460HR 460HR 460SI 46031 460HR 460HR 460HR 460HR 460HR 460HR 46031 46031 460HR 520SI 52031 52031 52031 46031 46031 460HR 46031 46031 46031 460SI 46031 46031 46031 46031 460HR 460HR 460SI 460S1 46031 460HR 460HR 460HR 46031 46031 460HR 460HR 460S1 46031 46031 460HR 460HR 46031 460HR 460HR 460HR 460SI 460HR 460HR 460SI 460HR 46031 460HR 460HR 460HR 460HR 460HR 460HR

Framat.ome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS QUERY: QueryMl ROW TUBE VOLTS DEG CHN INO %TW LOCATION 10 10 10 10 10 10 10 10 10 10

1.0 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 46 48 49 52 53 55 57 58 60 61 64 1

9 10 12 13 14 15 16 18 20 23 24 25 26 27 28 29 30 32 33 34 35 37 41 43 48 51 52 54 1.92 4.06 0.32 1.86 5.95 10.06 3.46 8.83 14.54 0.23 7.88 0.99 3.18 0.48 3.07 10.02 3.57 0.61 0.24 10.13

1. 45 5.65 9.46 2.13 5.31 3.00 1.90 2.50 0.71 0.53 2.53 0.73 2.35 0.61 3.63
1. 47 4.44 7.17 1.16 0.80 3.72 0.00
1. 91 3.87 3.92 4.11 3.93 2.19 0.00 4.59 5.34 2.08 0.24 0.30 0.49 0.23 0.16 0.49 1.01 0.64 2.40 3.43 4.76 1.06 0.58
1. 77 2.03
1. 74 4.54 0.30 3.16 0.36 0.25 0.70 0.19 17 25 2

2 TEA TEA 3 TWO 7 TEA ONT ONT TEA DNT DNT VOL ONT TEA TEA 3 TWO 11 TEA DNT TEA 3 TWO 14 VOL ONT TEA ONT DNT ONT DNT TEA TEA TEA o

P 19 2

181 1 178 1 28 2

175 1 178 1 86 2

179 1 51 2

27 2

o P

20 2

181 1 21 2

157 P 132 2 175 1 23 2

174 1 178 1 182 1 181 1 20 2

22 2

25 2

54 P 3 TWO 14 P 3 TWO 10 2

TEA 72 24 69 23 P 3 TWO 14 2

TEA P 3 TWD 11 1

ONT 52 171 21 176 1 1761 8

2 50 2

TEA ONT ONT TEA P 3 TWD 14 2

TEA 19 o

36 25 25 21 23 27 o

22 30 21 59 114 70 83 73 150 87 53 24 25 27 70 101 31 24 23 19 o

20 o

101 79 o

P 3 P 3 P 3 P 3 TWD 0 32 72 73 TWD TWD TWO P 3 TWD 77 P 3 TWD 73 P 3 TWD 37 P 3 TWD 0 P 1 SCI 2

TEA 2

TEA P 3 TWO 5 2

VOL P 3 TWD 9 2

VOL P 3 P 3 P 3 P 3 2

2 2

TWO 4 TWO 12 18 12 TWO TWO TEA TEA TEA P 3 TWO 19 P 3 TWD 14 2

TEA 2

TEA 2

TEA 2

TEA P 3 TWD 7 2

TEA P 3 TWD 8 2

VOL P 3 TWD 16 P 3 TWD 5 UTE UTE 009 UTE LTE UTE UTE LTE 009 012 UTE UTE UTE 009 UTE 010 UTE 008 014 010 UTE LTE 010 015 UTE UTE UTE UTE 008 010 UTE 007 UTE 007 010 UTE 010 010 UTE 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 008 009 010 008 009 009 010 010 UTE UTE UTE 009 009 UTE UTE UTE UTE 010 UTE 014 002 009 009 MRPC/PLUS POINT

-0.30

-0.21

-0.58

-0.29

+10.29

-11.13

-0.22

+10.71

-0.25

+1. 01

-11.05

-0.18

-0.21

-0.74

-0.27

-0.42

-0.15

-0.51

+1. 31

+0.28

-0.18

+11.41

-0.15

-0.75

-12.05

-0.18

-0.25

-0.20

-0.68

-0.70

-0.19

+0.72

-0.23

+0.50

+0.00

-0.22

-0.65

-0.56

-0.19

-0.68

-0.12

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.15

-0.16

+0.63

-0.69

+0.73

+0.65

-0.71

+0.64

-0.64

-0.62

-0.21

-0.16

-0.16

+0.65

+0.63

-0.23

-0.23

-0.21

-0.27

+0.81

-0.20

+0.86

-1. 53

-0.64

-0.42 TO+115.6 TO+124.4 TO+133.3 T0+142.2 TO+1S1.1 TO+160.0 TO+168.9 TO+177.8 05/02/02 13:29:10 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE 009 009 UTE UTE LTE LTE UTE UTE UTE UTE LTE LTE 009 009 012 012 UTE UTE UTE UTE UTE UTE 009 009 UTE UTE 010 010 UTE UTE 008 008 014 014 010 010 UTE UTE LTE LTE 010 010 015 015 UTE UTE UTE UTE UTE UTE UTE UTE 008 008 010 010 UTE UTE 007 007 UTE UTE 007 007 010 010 UTE UTE 010 010 010 010 UTE UTE 010 010 UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE UTE UTE 008 008 009 009 010 010 008 008 009 009 009 009 010 010 010 010 UTE UTE UTE UTE UTE UTE 009 009 009 009 UTE UTE UTE UTE UTE UTE UTE UTE 010 010 UTE UTE 014 014 002 002 009 009 009 009 WAR WAR WAR WAR WAR WAR WAR WAR CL WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 2034 2034 4086 2033 4086 4086 2033 4086 4086 4086 4086 2034 2033 4086 2033 4086 2034 4086 4086 4086 2034 4086 4086 4086 4086 2034 2015 2009 4048 4048 2009 4048 2010 4046 4046 2010 4046 4046 2009 4046 2009 2010 2010 2010 2010 2010 2010 2010 2010 2010 2009 2010 4046 4046 4046 4046 4046 4046 4046 4046 2010 2010 2009 4046 4086 2033 2033 2033 2033 4086 2033 4086 4086 4086 4086 INLET INLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET INLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET Page 9 of 155 PROBE 460HR 460HR 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460HR 460SI 460HR 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460SI 460SI 460HR 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460SI 460SI 460HR 460HR 460HR 460HR 460SI 460HR 460SI 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION 11 11 11 11 11 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 59 61 63 64 65 1

2 4

5 8

10 11 12 l3 14 15 16 17 18 20 23 25 29 30 32 33 35 36 38 39 43 47 49 50 52 53 54 55 56 61 62 63 65 66 7.06 4.40 12.15 2.89 7.93 2.99 3.13 2.12 3.58 0.20 2.79 2.51 5.48 6.34 9.45 4.17 4.25 0.11 14.21 0.80 6.54 2.19

1. 83 4.03 2.26 0.36 3.26 0.55
1. 98 2.94 0.36 2.72 3.62 2.19 1.48 3.16 0.36 2.29 0.70 2.25 3.35 6.08 3.33 0.32
1. 35 0.95 0.39 2.48
1. 84 2.39 0.59 0.47 2.77 3.46 2.91 0.06 0.52 2.45 0.71 0.71 0.18 2.20 0.49 0.39 0.33 0.67 0.26 3.55 9.l3 0.12 0.61 12.86 12.57 14.92 15.85 ONT TEA ONT TEA ONT TEA TEA TEA TEA VOL TEA TEA ONT ONT ONT ONT ONT VOL ONT 171 1 25 2

175 1 22 2

173 1 20 2

22 2

23 2

25 2

85 2

24 2

24 2

169 1 166 1 169 1 168 1 170 1 57 2

172 1 76 P

167 1 174 1 20 2

22 2

22 2

133 20 3 TWO 8 DNT DNT TEA TEA TEA P 3 TWO 4 2

TEA 30 14 P 3 TWO 6 2

TEA 19 2

TEA 96 P

18 2

169 1 20 2

151 1 21 2

147 3 TWO 4 TEA 25 P 3 2

DNT TEA DNT TEA TWO 9 TEA 3 TWO 16 DNT 113 P 355 1 25 2

25 2

27 2

140 P 3 114 P 3 61 P 3 140 P 3 31 2

20 2

19 2

125 P 3 95 P 3 23 2

25 2

21 2

82 2

26 2

171 1 20 2

20 2

149 2 20 2

88 39 o

40 91 22 170 97 27 174 176 180 178 P 3 P 3 P 3 P 3 P 3 2

1 2

2 1

1 1

1 TEA TEA TEA TWO 8 27 17 9

TWD TWO TWO TEA TEA TEA TWD 14 TWO 11 TEA TEA TEA VOL TEA DNT SAl TWD 57 VOL TEA TWO 12 TWD TWD TWD TWO TEA ONT VOL TEA ONT ONT ONT ONT 9

8 16 6

010 UTE 010 UTE 010 UTE UTE UTE UTE 014 UTE UTE UTE UTE UTE UTS UTS 014 009 007 LTS LTS UTE UTE UTE 008 UTE 010 UTE UTE 010 UTE 010 UTE 010 UTE 010 UTE 010 011 UTE UTE UTE 007 010 009 010 UTE UTE UTE 009 009 UTE UTE UTE 014 UTE LTE UTE UTE 014 UTE 007 007 010 007 009 UTE 009 010 UTE 010 010 010 010

-0.47

-0.25

-0.25

-0.24

-0.56

-0.16

-0.22

-0.39

-0.17

+1.26

-0.17

-0.20

-5.47

-7.46

-11. 36

+3.62

+4.59

+1.02

+0.17

+0.76

-13.09

-11. 55

-0.08

-0.13

-0.16

-0.59

-0.19

-0.65

-0.18

-0.19

-0.73

-0.19

-0.62

-0.17

-0.74

-0.17

-0.65

-0.l3

-0.73

+4.16

-0.18

-0.20

-0.18

-0.71

-0.70

+0.68

-0.63

-0.17

-0.18

-0.13

+0.66

+0.68

-0.22

-0.26

-0.28

+1. 29

-0.17

+5.63

-3.54

-3.54

+0.82

-0.20

+0.70

-0.63

-0.64

-0.65

+0.60

-0.17

+0.43

+3.84 TO+7.01

-0.19

+0.08

+0.45

-0.22

-0.08 05/02/02 13:29:10 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG 010 010 UTE UTE 010 010 UTE UTE 010 010 UTE UTE UTE UTE UTE UTE UTE UTE 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTS UTS UTS 014 014 009 009 007 007 LTS LTS LTS LTS UTE UTE UTE UTE UTE UTE 008 008 UTE UTE 010 010 UTE UTE UTE UTE 010 010 UTE UTE 010 010 UTE UTE 010 010 UTE UTE 010 010 UTE UTE 010 010 011 011 UTE UTE UTE UTE UTE UTE 007 007 010 010 009 009 010 010 UTE UTE UTE UTE UTE UTE 009 009 009 009 UTE UTE UTE UTE UTE UTE 014 014 UTE UTE LTE LTE UTE UTS UTE UTS 014 014 UTE UTE 007 007 007 007 010 010 007 007 009 009 UTE UTE 009 009 010 010 UTE UTE 010 010 010 010 010 010 010 010 WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 4086 2033 4086 2033 4086 2034 2033 2015 2009 4074 2009 2010 4074 4074 4074 4074 4074 4074 4074 4074 4074 4074 2009 2009 2009 4074 2010 4074 2009 2010 4074 2010 4074 2009 4074 2010 4046 2009 4046 4046 2009 2010 2010 4046 4046 4046 4046 2009 2010 2010 4086 4086 2033 2034 2034 4086 2033 4086 2033 2033 4086 2034 4086 4086 4086 4086 4086 2034 4086 4086 2033 4086 4086 4086 4086 OUTLET INLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET OUTLET INLET OUTLET INLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET Page 10 of 155 PROBE 460SI 460HR 460SI 460HR 460SI 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460SI 460HR 460SI 460HR 460HR 460SI 460HR 460SI 460HR 460SI 460HR 460SI 460HR 460SI 460SI 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460SI 460SI 460HR 460HR 460HR 460SI 460HR 460SI 460HR 460HR 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 12 12 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 68 70 1

2 3

4 6

8 9

10 12 13 15 16 17 21 22 25 26 27 28 29 31 32 34 40 41 43 44 45 46 53 54 55 57 58 61 62 63 64 65 66 67 69 73 2.89 7.42 18.38 13.44 5.46 3.44 8.33 3.61 2.34 0.49

1. 38 0.57 2.41 0.53 3.57 18.37 2.91 1.85 0.65 0.57 13.50
1. 66 3.36 2.67 0.36 3.78 0.55
1. 70 0.62
1. 72
1. 74 2.86
1. 43 0.42 4.66 2.75 3.28 3.86
1. 75 0.35 2.36 3.12 2.68 0.37 0.43 3.98 2.59 2.97 0.81 2.84 0.38 4.21 4.85 3.30 0.43 2.88 0.34 5.97 0.95
1. 60 0.43 2.24 14.71 13.75 12.19 12.67 8.37 2.46
11. 97 18.83 3.65 10.38 3.66 7.92 7.23 TEA MCI SCI SCI ONT ONT ONT ONT TEA TEA TEA 21 2

25 1

35 1

34 1

181 1 173 1 174 1 173 1 27 2

47 2

16 2

74 P 3 TWO 6 2

TEA 17 3 TWO 6 TEA ONT TEA ONT 92 P

21 2

178 1 23 2

170 1 66 P 3 TWO 13 P 3 TWO 11 1

ONT 82 178 13 22 29 o

24 83 20 64 26 70 24 76 118 24 19 28 21 14 104 18 28 24 77 165 24 19 21 46 25 105 23 22 175 43 25 2

TEA 2

TEA 2

TEA P 3 TWO 6 2

TEA P 3 TWO 11 2

TEA P 3 TWO 12 2

TEA P 3 TWO 29 2

TEA P 3 TWO 24 P 3 TWO 8 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA P 3 TWO 8 2

TEA 2

TEA 2

TEA P 3 TWO 8 P 3 TWO 10 2

TEA 2

TEA 2

TEA P 3 TWO 9 2

TEA P 3 TWO 9 2

TEA 2

TEA 1

ONT P 3 TWO 10 2

TEA 81 P

179 1 16 2

22 2

107 P 22 2

181 1 176 1 176 1 175 1 174 1 22 2

178 1 189 1 173 1 179 1 22 2

187 1 188 1 3 TWO 8 DNT TEA TEA 3 TWO 10 TEA DNT DNT DNT DNT DNT TEA ONT DNT ONT ONT TEA DNT DNT UTE LTE LTE LTE UTE 015 014 LTE UTE UTE UTE 010 UTE 009 UTE 009 UTE UTE 008 008 009 UTE UTE UTE 008 UTE 010 UTE 010 UTE 010 UTE 010 010 UTE UTE UTE UTE UTE 010 UTE UTE UTE 008 009 UTE UTE UTE 010 UTE 009 UTE UTE 014 010 UTE 009 010 UTE UTE 009 UTE 010 010 010 010 010 UTE UTS 010 LTE LTE UTE 010 LTE

-0.18

+0.84

+0.07

+0.50

-11. 59

-0.38

+0.24

+11. 20

-0.18

-0.27

-0.19

+0.81

-0.18

+0.55

-0.15

+0.00

-0.16

-10.60

-0.71

-0.26

-0.31

-0.23

-0.14

-0.18

-0.74

-0.18

+0.37

-0.19

-0.73

-0.15

-0.77

-0.16

-0.72

-0.72

-0.21

-0.14

-0.17

-0.17

-0.16

-0.73

-0.15

-0.16

-0.24

-0.14

+0.64

-0.22

-0.28

-0.23

-0.52

-0.28

-0.64

-0.28

-0.29

-13.32

-0.69

-0.24

+0.65

-0.00

-0.25

-0.17

+0.07

-0.24

-0.08

+0.54

-0.33

+0.35

-0.55

-0.22

+12.70

-0.28

+10.38

+11.05

-0.24

+0.54

+11. 65 05/02/02 13:29:10 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE LTE LTE LTE LTE LTE LTE UTE UTE 015 015 014 014 LTE LTE UTE UTE UTE UTE UTE UTE 010 010 WAR UTE UTE 009 009 WAR UTE UTE 009 009 UTE UTE UTE UTE 008 008 WAR 008 008 WAR 009 009 UTE UTE UTE UTE UTE UTE 008 008 WAR UTE UTE 010 010 WAR UTE UTE 010 010 WAR UTE UTE 010 010 WAR UTE UTE 010 010 WAR 010 010 WAR UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 010 WAR UTE UTE UTE UTE UTE UTE 008 008 WAR 009 009 WAR UTE UTE UTE UTE UTE UTE 010 010 WAR UTE UTE 009 009 WAR UTE UTE UTE UTE 014 014 010 010 WAR UTE UTE 009 009 WAR 010 010 UTE UTE UTE UTE 009 009 WAR UTE UTE 010 010 010 010 010 010 010 010 010 010 UTE UTE UTS UTS 010 010 LTE LTE LTE LTE UTE UTE 010 010 LTE LTE 2034 704 704 704 4088 4088 4088 4088 2034 2015 2009 4074 2010 4074 2009 4074 2009 4048 4048 4048 4048 2010 2009 2009 4048 2010 4048 2010 4048 2009 4048 2010 4046 4046 2010 2009 2010 2009 2010 4046 2009 2009 2033 4088 4088 2033 2034 2033 4088 2033 4088 2033 2034 4088 4088 2033 4088 4089 2033 2034 4088 2033 4089 4089 4089 4088 4088 2033 4088 4088 4088 4088 2033 4129 4129 INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET INLET OUTLET INLET OUTLET INLET OUTLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 11 of 155 PROBE 460HR 380EX 380EX 380EX 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460SI 460HR 460SI 460HR 460SI 460HR 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460SI 460HR 460SI 460HR 460SI 460HR 460SI 460HR 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460SI 460SI 460HR 460HR 460HR 460SI 460HR 460SI 460HR 460HR 460SI 460SI 460HR 460SI 460SI 460HR 460HR 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460HR 460S1 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 2

3 6

8 10 11 12 13 14 15 16 18 19 20 23 24 25 26 27 29 30 32 34 35 37 39 40 45 49 54 57 64 4.79 2.91 1.21 2.64 2.26 0.00 0.59 1.21 1.53 1.61 1.29 0.98 0.00 2.34 10.55 0.66 0.51 5.48 2.05 2.39 2.21 17.41 1.28 4.34 0.68 5.05 1.96 3.04 0.00 0.35 0.77

1. 01 1.22 1.63 2.24 2.35 2.41 2.53 2.62 2.61 1.98 0.76 0.59 0.00 0.56 2.56 2.35 0.72 2.50 0.54 5.77 4.07 3.23 1.99 0.00 0.31 0.94
1. 54
1. 04 1.04 0.00 0.12 2.73 0.30 3.15 0.24 0.88
1. 62 2.38 2.67 2.99 3.25 1.16 2.54 6.55 185 357 50 19 17 o

14 16 19 18 20 24 o

17 174 107 78 24 173 178 174 178 17 20 62 20 20 21 o

34 22 23 24 26 26 27 27 27 27 27 28 32 198 o

43 21 23 101 21 o

19 19 22 21 o

27 23 25 26 46 o

59 20 1

ONT 1

ONT P 3 TWO 13 2

TEA P 1 SCI P 4 TWO 0 P 4 TWO 15 P 4 TWO 38 P 4 TWO 54 P 4 TWO 59 P 4 TWO 42 P 4 TWO 29 P 4 TWO 0 2

TEA 1

ONT P 3 TWO 7 P 3 TWO 5 2

TEA 1

ONT 1

ONT 1

ONT 1

ONT 2

TEA 2

TEA P 3 TWO 7 2

TEA 2

TEA P 1 SCI P 4 TWO 0 P 4 TWO 10 P 4 TWO 23 P 4 TWO 31 P 4 TWO 37 P 4 TWO 49 P 4 TWO 65 P 4 TWO 68 P 4 TWO 69 P 4 TWO 72 P 4 TWO 74 P 4 TWO 74 P 4 TWO 58 P 4 TWO 23 P 4 TWO 17 P 4 TWO 0 P 3 TWO 6 2

TEA 2

TEA P 3 TWO 8 2

TEA P 3 TWO 9 2

TEA 2

TEA 2

TEA P 1 SCI P 4 TWO 0 P 4 TWO 3 P 4 TWO 33 P 4 TWO 74 P 4 TWO 40 P 4 TWO 40 P 4 TWO 0 2

VOL 2

TEA 78 P

21 2

133 2 23 2

24 2

24 2

18 2

22 2

20 2

26 2

22 2

3 TWO 6 TEA VOL TEA TEA TEA TEA TEA TEA TEA TEA 176 1 ONT UTS UTS 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 010 008 UTE UTE UTE UTE 009 UTE UTE 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 UTE UTE 010 UTE 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 UTE 009 UTE 003 UTE UTE UTE UTE UTE UTE UTE UTE 010

+13.23

+11. 91

-0.49

-0.17

-0.19

-0.19

-0.19

-0.19

-0.19

-0.19

-0.19

-0.19

-0.19

-0.15

+0.00

-0.67

+0.54

-0.18

-8.31

-9.39

-7.31

+0.01

-0.15

-0.15

+0.48

-0.17

-0.17

-0.14

-0.14

-0.14

-0.14

-0.14

-0.14

-0.14

-0.14

-0.14

-0.14

-0.14

-0.14

-0.14

-0.14

-0.14

-0.14

-0.14

-0.67

-0.23

-0.18

-0.63

-0.16

+0.60

-0.16

-0.20

-0.15

-0.21

-0.21

-0.21

-0.21

-0.21

-0.21

-0.21

-0.21

+1.20

-0.17

-0.69

-0.14

+3.52

-0.14

-0.18

-0.23

-0.42

-0.29

-0.26

-0.29

-0.25

-0.63 TO+151.1 TO+160.0 TO+168.9 TO+177.8 TO+186.7 TO+195.6 TO+204.4 TO+213.3 TO+53.3 TO+62.2 TO+71.1 TO+80.0 TO+88.9 TO+97.8 TO+106.7 TO+115.6 TO+124.4 TO+133.3 TO+142.2 TO+151.1 TO+160.0 TO+168.9 T0+177.8 TO+186.7 TO+35.6 T0+44.4 TO+53.3 TO+62.2 TO+71.1 TO+80.0 TO+88.9 05/02/02 13:29:10 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTS UTS UTS UTS 010 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 009 010 010 008 008 UTE UTE UTE UTE UTE UTE UTE UTE 009 009 UTE UTE UTE UTE 010 010 UTE UTE UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS 010 010 UTE UTE UTE UTE 010 010 UTE UTE 010 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 014 UTE UTE 009 009 UTE UTE 003 003 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 010 WAR CL WAR WAR WAR CL WAR WAR WAR CL WAR 4089 4089 4074 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 4074 4074 4074 2010 4074 4074 4074 4074 2009 2010 4074 2009 2010 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 2009 4074 2010 2009 4074 2009 4045 2009 2010 2009 2009 2009 2009 2009 2009 2009 2009 2009 4046 2010 4046 2009 4046 2010 2010 2033 2034 2033 2033 2033 2033 4089 OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET Page 12 of 155 PROBE 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460HR 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460SI 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460S1 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 14 14 14 14 14 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 65 66 67 71 75 2

3 5

6 8

14 15 17 18 19 22 26 27 28 29 31 35 36 37 43 44 50 54 55 60 64 67 70 71 72 73 17.50 12.19 14.83 0.35 0.46 0.19 8.85 0.19 7.78 5.03 2.91 5.70

1. 55
1. 90 0.00 0.88 2.13 2.50
1. 67 2.05 0.00
1. 30 4.17 2.12 12.84 2.95
1. 28 0.00 0.75
1. 30
1. 38 1.12 0.80 0.00 2.69
1. 04 4.04 0.70 0.36 3.07 2.92 0.50 0.65 0.41 0.67 3.63 1.24 2.56
1. 96 1.92 2.93 1.13
1. 77 3.82 6.95 0.17 0.68 0.96 2.78 0.38 14.45 0.20 10.97 0.68 5.03 9.98 3.65 0.17 12.47 7.50 6.02 1.02 15.46 7.26 14.96 181 1 178 1 179 1 77 2

49 P 4 77 2

182 1 106 2 183 1 178 1 22 2

177 1 25 2

19 P 1 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 2

o 21 18 15 19 22 o

59 25 21 2

175 1 ONT ONT ONT SVI TWO 78 SAl ONT TWO 19 ONT DNT TEA ONT TEA SCI TWO 0 TWO 15 42 52 31 40 o

14 TWO TWO TWO TWO TWO TWO TEA TEA ONT 23 17 o

2 TEA P 1 SCI P 3 TWO 0 24 45 48 38 26 o

14 P 3 TWO 14 P 3 TWO 12 P 3 TWO 13 P 3 TWO 15 P 3 TWO o

P 3 TWO 22 2

TEA 53 22 P 3 TWO 11 2

TEA 69 107 16 P 3 TWO 7 P 3 TWO 4 2

TEA 24 2

TEA 54 74 49 o

23 18 17 18 P 3 P 3 P 3 P 3 2

2 2

2 TWO 5 TWO 7 TWO 4 TWO TEA TEA TEA TEA TEA TEA TEA TEA TEA ONT VOL 12 18 2

19 2

16 2

36 2

22 2

173 1 63 2

86 114 26 P 3 TWO 9 P 3 TWO 19 2

TEA 16 o

P 3 1

TWO 8 ONT VOL ONT 78 187 67 P

171 1 182 1 24 2

83 2

181 1 181 1 181 1 27 2

184 1 29 2

190 1 2

1 3 TWO 9 ONT ONT TEA VOL ONT ONT ONT TEA ONT TEA ONT 010 010 010 012 012 010 010 010 LTE UTS UTE 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 UTE UTE 009 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 UTE 010 009 UTE UTE 010 010 010 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE 013 014 008 009 UTE 009 010 014 010 008 LTE UTE UTE 014 010 LTE UTE UTE 010 UTE 010

-0.07

+0.18

+0.01

+0.75

+0.75

+1.06

-0.01

+1.06

+10.86

+12.74

-0.28

+0.59

-0.20

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

+0.67

-0.20

-0.16

+0.00

-0.19

-0.20

-0.20

-0.20

-0.20

-0.20

-0.20

-0.20

-0.20

-0.18

-0.70

-0.19

+0.71

+0.44

-0.17

-0.18

-0.69

-0.65

-0.58

-0.75

-0.17

-0.19

-0.15

-0.13

-0.14

-0.16

-0.16

-0.82

-0.22

-5.14

+1. 45

+0.58

+0.64

-0.64

+0.72

-0.46

+0.78

+0.27

+0.69

+10.95

-11. 42

-0.27

+0.54

-0.09

+11.17

-11. 77

-0.11

-0.07

-0.23

-0.27 TO+13.3 TO+22.2 TO+31.1 TO+40.0 TO+48.9 TO+57.8 TO+66.7 TO+62.2 TO+71.1 TO+80.0 TO+88.9 TO+97.8 TO+106.7 TO+115.6 05/02/02 13:29:10 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG 010 010 010 010 010 010 012 012 012 012 010 010 010 010 010 010 LTE LTE UTS UTS UTE UTE 010 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 010 UTE UTE UTE UTE 009 009 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 010 UTE UTE 010 010 009 009 UTE UTE UTE UTE 010 010 010 010 010 010 010 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 013 013 014 014 008 008 009 009 UTE UTE 009 009 010 010 014 014 010 010 008 008 LTE LTE UTE UTE UTE UTE 014 014 010 010 LTE LTE UTE UTE UTE UTE 010 010 UTE UTE 010 010 CL WAR CL/CS WAR WAR WAR WAR WAR WAR WAR wAR WAR WAR WAR 4089 4089 4089 4129 4129 4129 4129 4129 4089 4089 2034 4074 2010 2010 2010 2010 2010 2010 2010 2010 2010 4074 2009 2009 4074 2010 2010 2010 2010 2010 2010 2010 2010 2010 2009 4074 2010 4074 4074 2009 2009 4074 4074 4074 4045 2009 2010 2009 2009 2010 2009 2010 2034 2033 4089 4089 4129 4089 2034 4089 4089 4129 4129 4129 4129 4089 2033 4130 4130 4089 4089 2034 4089 2033 4089 OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET INLET OUTLET OUTLET INLET INLET INLET INLET OUTLET INLET INLET INLET OUTLET OUTLET INLET OUTLET INLET OUTLET Page 13 of 155 PROBE 460SI 460S1 460S1 460S1 460S1 460S1 460S1 460S1 460S1 460S1 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460S1 460S1 460HR 460HR 460S1 460S1 460S1 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460S1 460S1 460S1 460HR 460S1 460S1 460S1 460S1 460S1 460S1 460S1 460HR 460S1 460SI 460S1 460S1 460HR 460S1 460HR 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS ~ MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION 15 15 15 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 76 77 78 2

3 4

5 6

7 8

9 10 11 14 15 16 18 19 20 22 24 25 26 27 28 29 30 31 32 33 36 37 39

11. 20 7.25 5.90 4.62 15.37
1. 85 3.62 4.15 0.79 6.89 7.25 6.16 7.99 9.67 4.00 8.96 19.19 0.42 2.15 6.91 14.57 7.14 2.81 7.88 0.13 7.21 3.19 2.27
1. 02 3.04 3.34 0.54
1. 98 0.62 0.00 0.61 1.14
1. 42 0.90 0.93 0.00
1. 79 3.34 2.96
1. 83 0.54 3.55 2.20 2.64
1. 63 1.05 2.98 3.87 0.39 3.12 0.46 2.70 4.47 3.82 5.23 0.76
1. 36 0.70 0.49 0.94 1.22 0.26 0.37 0.63 0.98 0.98 0.82 0.48 0.32 0.17 DNT DNT DNT TEA DNT TEA DNT TEA 3 TWD 8 DNT DNT TEA DNT DNT TEA ONT DNT 3 TWO 4 TEA DNT DNT DNT TEA DNT VOL ONT TEA TEA 186 1 181 1 178 1 27 2

2 1

18 2

181 1 19 2

63 P

176 1 177 1 24 2

170 1 173 1 29 2

173 1 177 1 103 P 18 2

181 1 177 1 183 1 24 2

176 1 77 2

183 1 18 2

18 2

75 P 3 TWD 11 2

TEA 29 19 134 18 57 o

15 12 15 34 38 o

18 25 21 24 91 22 20 24 181 177 23 23 o

22 o

23 25 23 23 72 22 o

o 19 29 32 34 29 27 31 33 28 46 79 2

TEA P 3 TWD 6 2

TEA P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 1 2

2 2

TWD 7 o 16 32 43 24 25 o

TWD TWD TWD TWD TWD TWD TWD SCI TEA TEA TEA P 3 TWD 6 2

TEA 2

TEA 2

TEA P 3 ONT P 3 ONT 2

TEA 2

TEA P 3 TWD 7 2

TEA P 3 TWO 8 2

TEA 2

TEA 2

TEA 2

TEA P 3 TWO 15 2

TEA P 3 TWO 12 P 3 TWO 9 2

TEA P 1 SCI P 3 TWD 0 P 3 TWO 60 P 3 TWD 79 P 3 TWO 98 P 3 TWD 98 P 3 TWD 89 P 3 TWD 68 P 3 TWD 56 P 3 TWD 0 010 LTE UTE UTE 010 UTE 010 UTE 010 UTE LTE UTE UTE LTE UTE 013 009 008 UTE UTE 009 LTE UTE UTE 013 LTE UTE UTE 009 UTE UTE 009 UTE 009 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 UTE UTE UTE 001 001 UTE UTE 009 UTE 010 UTE UTE UTE UTE 010 UTE 009 008 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE

+0.63

+10.19

-11.47

-0.24

+0.45

-0.27

+0.70

-0.18

+0.76

-10.64

+8.62

-0.16

-11.36

+8.78

-0.13

+12.91

+0.00

-0.11

-0.17

-10.83

-0.02

+10.49

-0.23

-11. 40

+0.89

+10.59

-0.17

-0.14

-0.66

-0.13

-0.16

+0.58

-0.09

-0.67

-0.16

-0.16

-0.16

-0.16

-0.16

-0.16

-0.16

-0.16

-0.16

-0.17

-0.16

+0.60

-0.16

-0.16

-0.14

-21.48

-20.45

-0.14

-0.14

+0.41

-0.16

-0.76

-0.17

-0.13

-0.15

-0.14

-0.71

-0.16

+0.63

-0.77

-0.18

-0.18

-0.18

-0.18

-0.18

-0.18

-0.18

-0.18

-0.18

-0.18

-0.18 TO+271.1 TO+280.0 TO+288.9 TO+297.8 TO+306.7 TO+315.6 TO+324.4 TO+13.2 TO+22.0 TO+30.7 TO+39.5 TO+48.3 TO+57.1 TO+65.9 TO+74.6 TO+83.4 05/02/02 13:29:10 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG 010 010 LTE LTE UTE UTE UTE UTE 010 010 UTE UTE 010 010 UTE UTE 010 010 UTE UTE LTE LTE UTE UTE UTE UTE LTE LTE UTE UTE 013 013 009 009 008 008 UTE UTE UTE UTE 009 009 LTE LTE UTE UTE UTE UTE 013 013 LTE LTE UTE UTE UTE UTE 009 009 UTE UTE UTE UTE 009 009 UTE UTE 009 009 UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE UTE UTE UTE UTE 010 010 UTE UTE UTE UTE UTE UTE 001 001 001 001 UTE UTE UTE UTE 009 009 UTE UTE 010 010 UTE UTE UTE UTE UTE UTE UTE UTE 010 010 UTE UTE 009 009 008 008 UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS WAR WAR WAR WAR WAR CL WAR WAR WAR WAR WAR WAR CL 4130 4089 4089 2033 4089 2034 4074 2009 4074 4074 4074 2009 4074 4074 2010 4074 4074 4074 2009 4074 4074 4074 2010 4074 4074 4074 2009 2010 4074 2009 2010 4074 2009 4074 2010 2010 2010 2010 2010 2010 2010 2010 2009 2009 2010 4074 2009 2009 2009 4045 4045 2009 2010 4045 2009 4045 2010 2009 2010 2009 4045 2010 4045 4045 2010 2078 2078 2078 2078 2078 2078 2078 2078 2078 2078 INLET OUTLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET OUTLET INLET OUTLET INLET INLET INLET INLET OUTLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 14 of 155 PROBE 460SI 460SI 460SI 460HR 460SI 460HR 460SI 460HR 460SI 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460HR 460SI 460SI 46081 460HR 460HR 460SI 460HR' 460HR 460SI 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 4608I 460HR 460HR 460HR 460SI 460SI 460HR 460HR 460SI 460HR 460SI 460HR 460HR 460HR 460HR 460SI 460HR 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 17 17 17 17 17 17 44 53 55 56 59 60 61 64 65 67 68 70 72 73 75 77 79 80 81 1

3 4

6 7

9 2.69 2.59 0.18 0.08 1.27 1.27 0.35 0.33 0.00 0.09 0.23 0.12 0.10 0.12 0.15 0.07 0.41 0.06 0.00

1. 94 2.23 3.41 2.20 0.90 0.36 0.15 10.01 7.16 7.14 2.81 8.82 15.05 8.87 2.41 10.14
11. 23 4.54 6.30 20.76 4.33
1. 31 5.72 3.77 2.60 5.42 2.33 0.00 0.28 0.55 1.17
1. 95 2.03
1. 46 0.53 0.31 0.00 2.50 7.78 0.35 3.16 6.74 6.03 4.54 7.20 9.94 4.62 6.59 3.66 7.23 0.05 5.08 4.47 4.47 3.81 2.44 23 24 67 68 19 19 2

2 2

2 2

2 92 P 3 41 P 3 o

P 3 63 P 3 27 P 3 50 P 3 43 P 3 34 P 3 29 P 3 22 P 3 27 P 1 2

P 3 TEA TEA VOL VOL TWD 54 8AI TWD 8 TWD 8 TWD 0 TWO 16 TWO TWO TWO TWO TWO TWO 8CI 59 24 19 22 31 13 TWD 11 TWD 0 TEA TEA TEA ONT TEA o

P 3 24 2

23 2

24 2

173 1 21 2

67 P 3 TWD 9 2

VOL 63 175 178 178 23 179 180 179 24 180 178

28.

168 190 172 21 167 162 22 176 28 o

56 34 14 18 19 19 27 52 o

19 173 1

1 1

2 1

1 1

2 1

1 2

1 1

1 2

1 1

2 1

P 1 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 2

1 81 P 3 23 2

182 1 177 1 27 2

171 1 175 1 178 1 23 2

176 1 168 1 67 2

167 1 24 2

176 1 171 1 25 2

DNT DNT DNT TEA DNT DNT DNT TEA DNT DNT TEA DNT DNT DNT TEA ONT ONT TEA ONT 8CI TWO 0 TWO 6 TWO TWO TWO TWO TWO TWO TWO TWO 13 30 53 56 39 13 7 o TEA DNT TWO 4 TEA DNT DNT TEA ONT DNT ONT TEA DNT DNT VOL DNT TEA ONT ONT TEA UTE UTE 014 014 UTE UTE 007 007 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 012 UTE 009 014 LTE 010 UT8 UTE LTE 010 UTE UTE 010 010 UTE LTE 010 UTE UTE LTE UTE UTE 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 003 010 UTE UTE LTE UTE LTE 009 UTE UTE LTE 009 013 UTE UTE LTE UTE UTE

-0.27

-0.26

+1. 86

+1. 66

-3.77

-3.77

+0.72

-0.64

-3.66

-3.66

-3.66

-3.66

-3.66

-3.66

-3.66

-3.66

-3.66

-3.66

-3.66

-0.24

-0.24

-0.33

+1.39

-0.24

+0.69

+1. 02

+10.50

-0.51

+11.85

-0.23

+10.49

-0.00

-10.94

-0.18

+0.54

-0.47

-0.22

+10.22

-0.06

-11.17

-0.27

+11. 63

-11.75

-0.18

+0.50

-0.26

-0.26

-0.26

-0.26

-0.26

-0.26

-0.26

-0.26

-0.26

-0.26

-0.26

-0.21

-9.86

+0.71

-0.31

-10.88

+8.74

-0.22

+8.82

+0.13

-10.81

-0.23

+10.38

-0.29

+1.16

-11.66

-0.23

+10.78

-11.51

-0.25 TO+293.3 TO+302.2 TO+311.1 TO+320.0 TO+328.9 TO+337.8 TO+346.7 TO+355.6 TO+4.4 TO+13.3 TO+338.1 TO+346.9 TO+355.7 TO+4.5 TO+13.3 TO+22.1 TO+30.8 TO+39.6 TO+48.4 TO+57.2 05/02/02 13:29:10 Component: S/G B Page 15 of 155


~--------

EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE 014 014 014 014 UTE UT8 UTE UT8 007 007 007 007 UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UT8 UTE UT8 UTE UT8 UTE UT8 UTE UTS UTE UT8 UTE U'rE UTE UTE UTE UTE 012 012 UTE UTE 009 009 014 014 LTE LTE 010 010 UTS UT8 UTE UTE LTE LTE 010 010 UTE UTE UTE UTE 010 010 010 010 UTE UTE LTE LTE 010 010 UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE 010 010 UTE UTS UTE UT8 UTE UT8 UTE UT8 UTE UT8 UTE UT8 UTE UT8 UTE UT8 UTE UT8 UTE UT8 UTE UT8 UTE UTE 003 003 010 010 UTE UTE UTE UTE LTE LTE UTE UTE LTE LTE 009 009 UTE UTE UTE UTE LTE LTE 009 009 013 013 UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE CS WAR WAR WAR CL WAR 2033 2033 4089 4089 2034 2034 4089 4089 2033 2033 2033 2033 2033 2033 2033 2033 2033 2033 2033 2034 2033 2034 4089 2033 4089 4089 4089 4089 4089 2033 4089 4089 4089 2033 4089 4089 2033 4090 4090 4090 2033 4090 4090 2033 4090 2033 2033 2033 2033 2033 2033 2033 2033 2033 2033 2033 2034 4074 4074 2015 4074 4074 2016 4066 4066 4066 2015 4107 4066 4066 4066 2016 4066 4066 2015 INLET INLET OUTLET OUTLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET PROBE 460HR 460HR 460SI 46081 460HR 460HR 46081 46081 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460SI 460SI 46081 46081 46081 460HR 4608I 4608I 46081 460HR 4608I 460SI 460HR 46081 460SI 460SI 460HR 460SI 46081 460HR 46081 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 46081 460SI 460HR 46081 46081 460HR 46081 460SI 46081 460HR 460SI 46081 460SI 46081 460HR 460SI 460SI 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMI ROW TUBE VOLTS OEG CHN INO %TW LOCATION 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 18 10 II 12 15 17 18 20 22 23 26 27 28 29 32 34 35 37 38 39 40 41 42 43 44 46 47 50 58 63 65 66 67 68 69 71 72 73 75 76 77 78 79 80 82 1

0.44 0.05 5.46 4.64

1. 99 3.39 2.60 0.64 2.49 2.34 0.64 2.39 0.58 2.46 3.98 2.94 2.30 3.37 0.34 0.54 0.68 1.83 2.03 5.45 0.21 3.46 0.33 2.14 2.42 2.07 2.52 0.19
1. 68 2.05 2.45 4.90 4.82 4.14 2.26 2.22 0.31 0.34 0.43 2.17 3.13 0.20 1.26 0.39 0.95
11. 06 4.70 0.19 3.96 2.55 1.96 4.ll 4.20 3.25 3.52 3.17 4.72 4.52 3.55 2.70 0.16 1.09 9.67 14.90 4.08
11. 70 0.61 8.03 2.00 4.07 0.08 3 TWO II VOL TEA TEA ONT ONT TEA 120 P 100 2 22 2

27 2

164 1 169 1 23 2

97 P 3 TWO 16 2

TEA 26 24 2

TEA 42 23 P 3 TWO 16 2

TEA 3 TWO 14 ONT TEA TEA TEA TEA VOL 3 TWO 10 ONT TEA TEA TEA 50 P

184 1 28 2

23 2

201 2 22 2

74 2

18 P

161 1 16 2

25 2

24 2

o P 3 TWO 4 2

TEA 22 3 TWO 6 TEA TEA TEA TEA VOL TEA TEA TEA ONT ONT ONT TEA ONT 3 TWO 7 3 TWO 7 3 TWO 9 TEA TEA o

P 21 2

27 2

16 2

27 2

89 2

23 2

20 2

21 2

176 1 177 1 168 1 17 2

143 1 159 P ll3P 133 P 14 2

23 2

155 P 3 TWO 4 2

TEA 7

167 P 14 2

178 1 170 1 90 2

154 1 151 1 19 2

155 1 164 1 150 1 159 1 162 1 27 2

171 1 25 2

28 2

83 2

27 2

14 1

30 1

166 1 171 1 72 2

179 1 26 2

22 2

80 2

3 TWO 9 TEA ONT ONT VOL ONT ONT TEA ONT ONT ONT ONT ONT TEA ONT TEA TEA VOL TEA SAl SCI ONT ONT VOL ONT TEA TEA VOL 009 014 UTE UTE UTE UTE UTE 007 UTE UTE 010 UTE 010 UTE UTE UTE UTE UTE 009 010 UTS UTE UTE UTE 009 UTE 007 UTE UTE UTE UTE 014 UTE UTE UTE UTE UTE UTE UTE 005 009 009 009 UTE UTE 010 UTE 010 UTE LTE LTE 014 UTE UTE UTE LTE LTE 002 UTE UTE UTE 010 UTE UTE 010 UTE UTE LTE LTE 010 014 UTS UTE UTE 012

-0.65

+1. 55

-0.19

-0.18

-5.75

-4.30

-0.13

-0.64

-0.20

-0.28

-0.61

-0.20

-0.73

-4.22

-0.21

-0.21

-0.25

-0.29

+0.64

-0.50

-19.20

-0.24

-0.23

-0.13

-0.70

-0.26

-0.24

-0.19

-0.27

-0.15

-0.26

+0.93

-0.23

-0.30

-0.23

-3.76

-4.12

-6.35

-0.47

-2.36

-0.74

+0.74

-0.73

-0.24

-0.17

+0.50

-0.18

-0.74

-0.21

+11. 20

+10.81

+0.98

-11. 48

-11.47

-0.19

+10.94

+10.84

-12.82

-11. 84

-11. 50

-0.16

-0.47

-0.17

--0.14

+2.61

-0.12

-0.24

+0.17

+11.13

-0.10

+0.82

+12.76

-0.17

-0.26

+1.05 05/02/02 13:29:10 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG 009 009 WAR 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 007 007 WAR UTE UTE UTE UTE 010 010 WAR UTE UTE 010 010 WAR UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 009 010 010 WAR UTS UTS UTE UTE UTE UTE UTE UTE 009 009 WAR UTE UTE 007 007 WAR UTE UTE UTE UTE UTE UTE UTE UTE 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 005 005 009 009 WAR 009 009 WAR 009 009 WAR UTE UTE UTE UTE 010 010 WAR UTE UTE 010 010 WAR UTE UTE LTE LTE LTE LTE 014 014 UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE 002 002 UTE UTE UTE UTE UTE UTE 010 010 UTE UTE UTE UTE 010 010 UTE UTE UTE UTE LTE LTE LTE LTE 010 010 014 014 UTS UTS UTE UTE UTE UTE 012 012 4066 4066 2016 2015 4066 4066 2016 4066 2015 2015 4066 2016 4066 4066 2016 2016 2015 2016 4045 4045 4045 2016 2015 2016 4045 2015 4045 2016 2015 2016 2015 4045 2033 2034 2033 4090 4<)90 4090 2034 4090 4090 4090 4090 2037 2037 4090 2037 4090 2037 4090 4090 4090 4090 4090 2037 4090 4090 4090 4090 4090 2038 4090 2037 2037 4090 2037 604 704 4090 4090 4090 4090 2037 2038 4107 OUTLET OUTLET INLET INLET OUTLET OUTLET INLET OUTLET INLET INLET OUTLET INLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET INLET OUTLET INLET INLET INLET INLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET Page 16 of 155 PROBE 460SI 460SI 460HR 460HR 460SI 460SI 460HR 460SI 460HR 460HR 460SI 460HR 460SI 460SI 460HR 460HR 460HR 460HR 460SI 460SI 460SI 460HR 460HR 460HR 460SI 460HR 460SI 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460HR 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460HR 460HR 460SI 460HR 410MB 380EX 460SI 460SI 460SI 460SI 460HR 460HR 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 2

5 6

7 8

9 10 13 17 18 22 23 28 30 31 33 36 37 38 39 40 41 45 54 56 57 0.78 3.64

1. 88 3.89 3.04 7.94 3.35 3.16
11. 42 5.51 12.13 8.13 3.59 8.35 6.33 6.79 5.91 6.53 0.00 0.74
1. 47 3.56 4.69 3.52 3.26 2.99 2.55 1.99 1.17 0.00 4.26 2.79 2.91 0.27 1.97 3.16 2.87
1. 76 0.74 0.26 0.09 4.64 2.23 0.00 0.41 0.42 0.63 0.86 1.14
1. 49
1. 65
1. 62
1. 48 1.23 0.49 0.38 0.00
1. 48 0.12 0.12 3.58
1. 77
1. 61
1. 43 3.10 2.51 4.90 0.61 4.34 0.25 0.71 8.61 3.92
1. 94 4.83 o

27 o

18 19 176 167 22 174 166 175 175 29 173 o

181 182 28 o

37 31 30 29 31 28 29 32 35 47 o

P 3 TWD 11 2

TEA P 3 TWD 24 2

TEA 2

TEA 1

DNT 1

DNT 2

TEA 1

DNT 1

DNT 1

DNT 1

DNT 2

TEA 1

DNT 1

DNT 1

DNT 1

DNT P 1 SCI P 3 TWD 0 P 3 TWD 13 P 3 TWD 26 P 3 TWD 66 P 3 TWD 90 P 3 TWD 65 P 3 TWD 60 P 3 TWD 54 P 3 TWD 46 P 3 TWD 35 P 3 TWD 20 P 3 TWD 0 1

DNT 166 152 1 19 2

141 P 23 2

22 2

13 2

18 2

o DNT TEA 3 TWD 7 TEA TEA TEA TEA P 3 TWD 13 P 3 TWD 5 2

VOL o

81 24 22 o

16 40 42 25 25 24 24 21 20 18 6

52 o o 64 64 23 11 20 18 24 17 21 134 174 50 124 186 190 16 23 2

TEA P 1 SCI P 3 TWD 0 P 3 TWD 9 P 3 TWO 10 P 3 TWD 15 P 3 TWD 23 P 3 TWD 34 P 3 TWD 56 P 3 TWD 71 P 3 TWD 68 P 3 TWD 56 P 3 TWD 39 P 3 TWD 11 P 3 TWD 9 P 3 TWD 0 P 3 TWD 23 2

SAl 2

TWD 70 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 1

VOL 1

DNT 2

VOL 1

VOL 1

DNT 1

DNT 2

TEA 2

TEA 011 UTE 008 UTE UTE UTE LTE UTE 009 LTE 009 UTE UTE 009 LTE UTS UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE UTE UTE 009 UTE UTE UTE UTE 005 009 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 UTS UTS UTE UTE UTE UTE UTE UTE UTE 015 UTS UTS UTS UTS LTE UTE UTE

-0.45

-0.29

+0.77

-0.12

-0.28

-10.92

+8.95

-0.20

-0.32

+8.99

-0.32

-11.12

-0.33

-0.42

+11.00

+11. 92

+11.43

-0.21

-0.21

-0.21

-0.21

-0.21

-0.21

-0.21

-0.21

-0.21

-0.21

-0.21

-0.21

-0.21

+11.29

-11.18

-0.21

-0.70

-0.20

-0.13

-0.22

-0.21

-0.45

+0.68

+1.19

-0.19

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.83

-14.87

-14.87

-0.23

-0.18

-0.17

-0.15

-0.25

-0.13

-0.26

-11.65

-18.04

-18.07

-15.38

+13.35

+11.10

-0.18

-0.19 TO+284.4 TO+293.3 TO+302.2 TO+311.1 TO+320.0 TO+328.9 TO+337.8 TO+346.7 TO+355.6 TO+4.4 TO+13.3 TO+22.2 TO+133.3 T0+142.2 TO+151.1 TO+160.0 TO+168.9 TO+177.8 TO+186.7 T0+195.6 TO+204.4 TO+213.3 TO+222.2 TO+231.1 TO+240.0 TO+248.9 05/02/02 13:29:11 Component: SIG B EXT EXT UTIL 1 UTIL 2 CAL # LEG 011 011 UTE UTE 008 008 UTE UTE UTE UTE UTE UTE LTE LTE UTE UTE 009 009 LTE LTE 009 009 UTE UTE UTE UTE 009 009 LTE LTE UTS UTS UTS UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE 009 009 UTE UTE UTE UTE UTE UTE UTE UTE 005 005 009 009 014 014 UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS 010 010 UTS UTS UTS UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 015 015 UTS UTS UTS UTS UTS UTS UTS UTS LTE LTE UTE UTE UTE UTE WAR WAR CL WAR WAR WAR CL WAR 4062 2015 4062 2016 2015 4107 4062 2016 4062 4066 4066 4066 2015 4066 4107 4107 4107 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 4066 4066 2016 4066 2015 2015 2016 2016 4045 4045 4045 2016 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 4045 4045 4045 2015 2015 2015 2016 2015 2016 2015 4093 4093 4093 4093 4093 4093 2037 2037 OUTLET INLET OUTLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET Page 17 of 155 PROBE 460SI 460HR 460SI 460HR 460HR 460SI 460SI 460HR 460SI 460S1 460SI 460S1 460HR 460SI 460SI 460S1 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460SI 460HR 460SI 460HR 460HR 460HR 460HR 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460S1 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460S1 460SI 460S1 460SI 460SI 460HR 460HR

Framatome ANP Inc.

Customer Name: Oconee unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION 18 18 18 18 18 18 18 18 18 18 18 18 18 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 65 67 68 70 71 72 77 78 79 81 82 83 84 1

2 4

5 6

7 8

9 10 11 12 13 16 17 18 19 21 22 23 28 29 30 31 32 37 0.40 0.11 1.72 2.61 3.77 0.56 2.33 4.78 0.41 7.28

1. 84 2.23 3.35 1.05 0.30 0.26 2.69 4.39 0.45 6.49 2.55 0.27 0.45
1. 28 2.32 0.00 0.30 0.72
1. 43
1. 32 0.69 0.00 1.14 2.81 4.41 3.10 6.70 3.45
1. 97
1. 81
1. 94
1. 93 0.38
1. 36
1. 79 0.38 2.59 1.21 0.46 2.41 0.73 0.12 0.11 0.07 0.24 0.47 0.50 0.50 0.48 0.49 0.22 0.07 3.65 2.21 0.08 0.87
1. 71
1. 41 0.77
1. 67 0.43 3.29 2.96 0.67 2.36 48 58 22 19 P 3 TWO 9 VOL TEA TEA 2

2 2

2 TEA P 3 TWO 13 2

TEA 24 143 35 187 75 P

189 1 18 2

175 1 31 2

73 P

82 2

118 P 20 2

173 1 98 2

175 1 22 2

62 2

76 2

21 2

21 1

ONT 3 TWO 9 ONT TEA ONT TEA 3 TWO 16 VOL 3 TWO 4 TEA ONT VOL ONT TEA VOL VOL TEA P 1 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 2

SCI o

168 10 21 18 41 o o 21 26 2

TWO 0 6

25 62 56 24 o

16 TWO TWO TWO TWD TWO TWO TWO 2

TEA TEA TEA ONT TEA TEA TEA TEA TEA 22 183 1 22 2

21 2

23 2

22 2

28 2

o P 3 TWO 5 2

TEA 22 10 o

23 23 o

26 36 13 4

140 33 21 21 16 19 25 40 45 23 24 73 20 18 27 20 17 o

21 28 38 16 2

TEA P 3 TWO 5 2

TEA 2

TEA P 3 TWO 6 2

TEA P 1 SCI P 3 TWO 0 P 3 TWO 33 P 3 TWO 26 P 3 TWO 48 P 3 TWO 67 P 3 TWO 69 P 3 TWO 69 P 3 TWO 68 P 3 TWO 68 P 3 TWO 46 P 3 TWO 0 2

TEA 2

TEA 2

VOL 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA P 3 TWO 8 2

TEA 2

TEA P 3 TWO 13 2

TEA 009 014 UTE UTE UTE 010 UTE LTE 010 UTE UTE 004 UTE 010 014 014 UTE LTE 013 UTE UTE 014 012 UTE UTE UTE UTE UTE UTE UTE UTE UTE 008 UTE UTE UTE 009 UTE UTE UTE UTE UTE 010 UTE UTE 009 UTE UTE 009 UTE 013 013 013 013 013 013 013 013 013 013 013 013 UTE UTE 014 UTE UTE UTE UTE UTE 010 UTE UTE 009 UTE

-0.73

+1. 05

-0.19

-0.11

-0.11

-0.80

-0.13

+10.88

-0.62

-11.46

-0.14

-9.68

-0.14

+0.72

+1. 42

+0.78

-0.21

+11.04

+0.70

-11. 72

-0.25

+1.17

+0.77

-0.22

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

+0.85

-0.14

-0.25

-0.23

-0.05

-0.20

-0.22

-0.17

-0.24

-0.24

+0.54

-0.21

-0.21

-0.72

-0.19

-0.19

+0.70

-0.27

+13.08

+13.08

+13.08

+13.08

+13.08

+13.08

+13.08

+13.08

+13.08

+13.08

+13.08

+13.08

-0.22

-0.17

+1.29

-0.21

-0.22

-0.24

-0.16

-0.22

-0.76

-0.24

-0.26

+0.61

-0.21 TO+164.4 TO+173.3 TO+182.2 TO+191.1 TO+200.0 TO+208.9 TO+217.8 TO+33.2 TO+42.6 TO+52.1 TO+61. 6 TO+71.1 TO+80.5 TO+90.0 TO+99.5 TO+108.9 TO+118.4 TO+127.9 05/02/02 13:29:11 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG 009 009 014 014 UTE UTE UTE UTE UTE UTE 010 010 UTE UTE LTE LTE 010 010 UTE UTE UTE UTE 004 004 UTE UTE 010 010 014 014 014 014 UTE UTE LTE LTE 013 013 UTE UTE UTE UTE 014 014 012 012 UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS 008 008 UTE UTE UTE UTE UTE UTE 009 009 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 010 UTE UTE UTE UTE 009 009 UTE UTE UTE UTE 009 009 UTE UTE 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 UTE UTE UTE UTE 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 010 UTE UTE UTE UTE 009 009 UTE UTE WAR WAR WAR WAR WAR CL WAR WAR WAR WAR WAR WAR 4093 4093 2037 2038 2038 4093 2037 4093 4093 4093 2038 4093 2037 4096 4096 4096 2038 4130 4096 4096 2037 4096 4096 2038 2015 2015 2015 2015 2015 2015 2015 2015 4062 2016 2015 2016 4062 2015 2016 2015 2016 2015 4062 2016 2015 4062 2015 2016 4062 2015 4107 4107 4107 4107 4107 4107 4107 4107 4107 4107 4107 4107 2016 2015 4045 2016 2015 2015 2016 2015 4045 2016 2015 4045 2016 OUTLET OUTLET INLET INLET INLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET OUTLET INLET INLET OUTLET INLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET INLET INLET INLET INLET OUTLET INLET INLET OUTLET INLET Page 18 of 155 PROBE 460S1 460SI 460HR 460HR 460HR 460SI 460HR 460SI 460SI 460SI 460HR 460S1 460HR 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460HR 460S1 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460HR 460S1 460HR 460HR 460S1 460HR 460S1 460S1 460S1 460S1 460S1 460S1 460S1 460SI 460SI 460S1 460SI 460S1 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460SI 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 38 39 40 42 43 45 46 49 54 56 57 61 67 72 73 75 76 77 78 79 80 81 82 84 85 1

7 9

11 12 14 15 16 17 19 24 25 26 29 32 33 34 36 37 40 44 47 49 53 61 68 69 70 0.46 0.11 3.40 0.12 2.38 3.89 2.34 2.22 3.44 0.13 3.39 6.95 6.14 5.89 0.14 0.13 0.54 3.15 1.30

1. 97 2.09 4.57 8.18 0.63 3.32 0.18 2.62 2.21
1. 73 0.53 2.09 0.45 2.29
1. 90 2.33 2.50 3.92 0.20 8.86 2.56 1.65 0.31 0.15 0.57 0.15 0.40 2.04 0.53 4.53 2.68 0.78 0.19 2.45 0.80
1. 59 2.44 0.34 0.28
1. 67 1.03 0.28 2.70 3.18 5.58
1. 99 0.15 3.68 0.26 5.79 0.17 2.51 1.12 4.12 3.06 2.64 o

49 20 103 20 21 21 21 172 68 182 182 174 183 73 99 90 196 111 16 18 184 184 27 23 76 21 21 18 65 23 70 21 16 24 36 24 116 179 20 17 60 92 39 65 78 17 118 22 21 o

82 24 o o 28 o o 23 18 P 3 TWO 8 2

VOL 2

TEA 2

VOL 2

TEA 2

TEA 2

TEA 2

TEA 1

ONT 2

VOL 1

ONT 1

ONT 1

ONT 1

ONT 2

VOL 2

VOL P 3 TWO 12 1

ONT 1

VOL 2

TEA 2

TEA 1

ONT 1

ONT P 3 TWO 14 2

TEA P 3 TWO 3 2

TEA 2

TEA 2

TEA P 3 TWO 12 2

TEA P 3 TWO 10 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

VOL 1

ONT 2

TEA 2

TEA P 3 TWO 8 2

VOL P 3 TWO 14 2

VOL P 3 TWD 10 2

TEA P 3 TWO 13 2

TEA 2

TEA P 3 TWO 13 9

PLP 2

TEA P 3 TWO 14 P 3 TWO 24 2

TEA P 3 TWO 6 P 3 TWO 5 2

TEA 2

TEA o

P 30 2

20 2

23 2

16 2

84 2

18 2

96 2

24 2

1182 21 2

25 2

25 2

20 2

20 2

3 TWO 5 TEA TEA TEA TEA VOL TEA VOL TEA VOL TEA TEA TEA TEA TEA 009 013 UTE 014 UTE UTE UTE UTE 008 010 LTE UTE LTE UTE 004 004 008 013 013 UTE UTE LTE UTE 009 UTE 009 UTE UTE UTE 009 UTE 009 UTE UTE UTE UTE UTE 011 009 UTE UTE 009 009 010 013 009 UTE 009 UTE UTE 010 014 UTE 010 010 UTE 009 009 UTE UTE 009 UTE UTE UTE UTE 014 UTE 010 UTE 014 UTE UTE UTE UTE UTE

+0.62

+1.27

-0.19

+1.27

-0.23

-0.18

-0.25

-0.25

-3.49

+1. 46

+10.89

-11. 72

+11.00

-11. 52

-26.80

-25.18

+0.68

-18.56

-18.38

-0.26

-0.13

+10.79

-11.14

+0.66

-0.11

+0.72

-0.21

-0.16

-0.21

+0.73

-0.15

+0.75

-0.25

-0.15

-0.24

-0.20

-0.25

+0.62

+0.14

-0.26

-0.27

-0.74

+0.43

+0.67

+1.08

-0.70

-0.26

-0.53

-0.24

-0.23

-0.80

+1.17

-0.20

-0.82

-0.80

-0.10

+0.67

+0.25

-0.22

-0.19

-0.79

-0.14

-0.19

-0.24

-0.12

+1.21

-0.17

+1. 36

-0.17

+1. 02

-0.17

-0.18

-0.23

-0.17

-0.20 05/02/02 13:29:11 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG 009 009 WAR 013 013 UTE UTE 014 014 UTE UTE UTE UTE UTE UTE UTE UTE 008 008 010 010 LTE LTE UTE UTE LTE LTE UTE UTE 004 004 004 004 008 008 WAR 013 013 013 013 UTE UTE UTE UTE LTE LTE UTE UTE 009 009 WAR UTE UTE 009 009 WAR UTE UTE UTE UTE UTE UTE 009 009 WAR UTE UTE 009 009 WAR UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 011 012 009 009 UTE UTE UTE UTE 009 009 WAR 009 009 010 010 WAR 013 013 009 009 WAR UTE UTE 009 009 WAR UTE UTE UTE UTE 010 010 WAR 014 014 UTE UTE 010 010 WAR 010 010 WAR UTE UTE 009 009 WAR 009 009 WAR UTE UTE UTE UTE 009 009 WAR UTE UTE UTE UTE UTE UTE UTE UTE 014 014 UTE UTE 010 010 UTE UTE 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 4045 4045 2016 4045 2015 2016 2038 2037 4130 4093 4093 4093 4093 4093 4093 4093 4093 4093 4093 2038 2037 4093 4093 4093 2037 4096 2038 2037 2038 4096 2037 4096 2038 2037 2038 2037 2038 4066 4066 2015 2015 4066 4066 4066 4066 4066 2015 4066 2015 2015 4045 4045 2015 4045 4045 2015 4045 4045 2015 2015 4045 2078 2015 2016 2015 4107 2037 4098 2037 4098 2038 2037 2038 2037 2038 OUTLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET INLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET INLET INLET OUTLET INLET INLET INLET INLET OUTLET INLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET Page 19 of 155 PROBE 460SI 460SI 460HR 460SI 460HR 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460HR 460SI 460HR 460HR 460HR 460SI 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460HR 460HR 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460SI 460HR 460SI 460HR 460SI 460HR 460HR 460HR 460HR 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 05/02/02 13:29:11 Component: S/G B


~---

ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION 20 20 20 20 20 20 20 20 20 20 20 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 71 72 73 74 75 76 78 80 81 82 84 1

4 5

10 11 12 14 15 16 17 18 20 21 23 24 29 30 34 35 37 38 47 48 51 53 57 58 60 61 64 71 72 76 78 79 82 3.38 3.00 0.37 2.19 3.68 3.21 2.08 2.63 1.40 0.22

1. 90 2.01 6.74 6.34 3.15 2.64 0.00 0.33 1.18 1.37
1. 78 2.14 2.17 2.50 2.16
1. 77
1. 79 1.46 0.47 0.00 0.14 0.13 0.36 4.28 0.27 0.33
1. 95 3.15 0.35 4.39 3.07 4.65 0.27 3.55 0.69 1.17 0.67 0.35 0.27 0.27 2.84 2.76 0.37 1.97 0.25 4.20 0.92 2.34 1.17 2.19 1.69
1. 88 2.20 4.70 0.36 3.15 9.48 0.19 6.94 2.64 0.36 1.59 4.67 3.02
1. 76 19 2

2 TEA TEA 26 122 P 23 2

27 2

26 2

19 2

21 2

24 2

72 2

21 2

25 2

175 1 177 P 21 2

26 3 TWD 8 o

33 18 18 20 21 23 21 21 20 23 24 28 o

122 87 40 TEA TEA TEA TEA TEA TEA VOL TEA TEA DNT 3 ONT TEA SCI P 1 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 2

2 TWD 0 TWD 6 TWD 31 TWD TWD TWD TWD TWD TWD TWO TWD TWO TWD TWD VOL VOL 37 48 59 60 69 60 48 49 39 10 o

P 3 TWD 10 2

TEA 22 139 P 116 2 19 2

22 2

124 2 174 1 175 1 20 2

38 3 TWD 7 VOL TEA TEA VOL ONT ONT TEA P 3 TWD 7 2

TEA 22 o

16 o o 90 90 21 22 o

31 o

23 o

21 16 21 184 181 21 25 40 23 172 65 25 18 93 26 28 26 28 P 3 TWO 12 2

P 3 P 3 P 4 P 4 2

2 TEA TWO 12 TWO 6 SVI TWO 12 TEA TEA P 3 TWO 7 2

TEA P 3 TWO 5 2

TEA P 3 TWO 15 2

TEA 2

TEA 2

TEA 1

ONT 1

ONT 2

TEA 2

TEA P 3 TWO 8 2

TEA 1

DNT 2

VOL 2

TEA 2

TEA 2

VOL 2

TEA 2

TEA 2

TEA 2

TEA UTE UTE 009 UTE UTE UTE UTE UTE UTE 013 UTE UTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 011 013 010 UTE 009 009 UTE UTE 009 UTE UTE UTE 009 UTE 008 UTE 009 009 014 014 UTE UTE 009 UTE 009 UTE 009 UTE UTE UTE UTE UTE UTE UTE 013 UTE LTS 008 UTE UTE 014 UTE UTE UTE UTE

-0.16

-0.15

+0.71

-0.13

-0.26

-0.14

-0.23

-0.27

-0.24

+1. 35

-0.16

-0.21

+10.98

-11.96

-0.23

-0.33

-0.33

-0.33

-0.33

-0.33

-0.33

-0.33

-0.33

-0.33

-0.33

-0.33

-0.33

-0.33

-0.33

-0.33

+0.81

+1. 48

-0.67

-0.23

-0.71

-0.75

-0.24

-0.23

-0.69

-1. 83

-2.92

-0.38

+0.65

-0.25

+0.74

-0.23

-0.83

+0.63

+0.82

+0.82

-0.23

-0.28

+0.67

-0.20

+0.64

-0.19

+0.74

-0.21

-0.10

-0.12

-12.85

-10.44

-0.22

-0.26

+0.72

-0.16

-4.28

+1. 72

-0.15

-0.31

+0.91

-0.20

-0.25

-0.26

-0.14 TO+115.6 TO+l24.4 TO+133.3 TO+l42.2 TO+151.1 TO+160.0 TO+168.9 TO+177.8 TO+l86.7 TO+195.6 TO+204.4 TO+213.3 TO+222.2 TO+231.1 EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE 009 009 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 013 013 UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS 011 012 013 014 010 010 UTE UTE 009 009 009 009 UTE UTE UTE UTE 009 009 UTE UTE UTE UTE UTE UTE 009 009 UTE UTE 008 008 UTE UTE 009 009 009 009 014 014 014 014 UTE UTE UTE UTE 009 009 UTE UTE 009 009 UTE UTE 009 009 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 013 013 UTE UTE LTS LTS 008 008 UTE UTE UTE UTE 014 014 UTE UTE UTE UTE UTE UTE UTE UTE WAR CL WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 2037 2038 4098 2037 2038 2037 2038 2038 2038 4100 2037 2038 4100 4100 2038 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 2015 4066 4066 4066 2016 4066 4066 2015 2015 4066 4066 4066 2016 4066 2015 4045 2016 4045 4045 4045 4045 2016 2015 4045 2015 4045 2016 4045 2016 2038 2037 4093 4093 2037 2037 4100 2037 4100 4100 2037 2038 4100 2037 2037 2038 2037 INLET INLET OUTLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET INLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET OUTLET INLET OUTLET INLET INLET INLET OUTLET OUTLET INLET INLET OUTLET INLET OUTLET OUTLET INLET INLET OUTLET INLET INLET INLET INLET Page 20 of 155 PROBE 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460HR 46051 46051 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460SI 460SI 460HR 460SI 46051 460HR 460HR 460SI 460SI 460SI 460HR 460SI 460HR 460SI 460HR 460SI 460SI 46051 460SI 460HR 460HR 46051 460HR 46051 460HR 460SI 460HR 460HR 460HR 460SI 460SI 460HR 460HR 460SI 460HR 460SI 460SI 460HR 460HR 460SI 460HR 460HR 460HR 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 21 21 21 21 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 85 87 88 90 2

5 6

10 11 12 14 17 21 22 23 25 26 29 30 31 32 34 36 37 38 40 42 44 46 47 48 49 51 52 53 55 56 63 66 68 75 77 78 79 80 81 88 0.59 0.20 2.10 0.52 6.09 8.97 6.04 0.88 7.42 0.28 6.77 3.12 1.12 0.00 0.93

1. 75 0.95
1. 42 0.00 0.25 0.38 0.06 2.91 2.73 2.67 0.50 0.79
1. 89 0.41 2.64 2.33 0.18 0.91 3.10 3.87 0.46 3.81 0.56 0.54 1.85 0.19 0.49 2.41 0.51 3.01
1. 34 2.71 0.55 0.76
1. 96 3.83 3.15
1. 68
1. 94 3.62
1. 90 3.27
1. 42 2.82 0.49 0.17 3.89 2.43 3.02 2.95 5.17 0.92
1. 44 2.93 0.96 2.68 2.31 3.02 2.44
1. 50 86 2

VOL 90 2

VOL 26 2

TEA 93 2

VOL 179 1 ONT 178 1 ONT 181 1 ONT 19 2

TEA 177 1 ONT 56 2

VOL 177 1 ONT 24 2

TEA 38 P 1 SCI o

P 3 TWO 0 24 P 3 TWO 37 26 P 3 TWO 75 33 P 3 TWO 38 44 P 3 TWO 61 o

P 3 TWO 0 80 2

VOL 78 9

PLP 108 2 VOL 27 2

TEA 18 2

TEA 22 2

TEA 56 P 3 TWO 10 63 P 3 TWO 15 19 2

TEA 144 P 3 TWO 6 18 2

TEA 18 2

TEA 79 2

VOL 23 2

TEA 21 2

TEA 27 2

TEA o

P 3 TWO 8 23 2

TEA 23 P 3 TWO 11 33 P 3 TWO 10 22 2

TEA o

P 3 TWO 3 38 P 3 TWO 9 24 2

TEA o

P 3 TWO 9 25 2

TEA 38 2

TEA 24 2

TEA 29 P 3 TWO 10 53 P 3 TWO 15 21 2

TEA 27 2

TEA 22 2

TEA 12 2

TEA 178 1 ONT 26 2

TEA 19 2

TEA 20 2

TEA 26 2

TEA 21 2

TEA 46 P 3 TWO 11 88 2

VOL 186 1 ONT 25 2

TEA 190 1 ONT 184 1 ONT 178 1 ONT 117 P 3 TWO 19 14 2

TEA 22 2

TEA 20 2

TEA 23 2

TEA 24 2

TEA 20 2

TEA 22 2

TEA 18 2

TEA 014 014 UTE 013 LTE UTE UTE UTE LTE 013 UTE UTE UTE UTE UTE UTE UTE UTE UTE 013 013 014 UTE UTE UTE 009 010 UTE 009 UTE UTE 014 UTE UTE UTE 009 UTE 009 009 UTE 007 010 UTE 013 UTE UTE UTE 009 009 UTE UTE UTE UTE 011 UTE UTE UTE UTE UTE 010 010 LTS UTE LTE LTE LTE 008 UTE UTE UTE UTE UTE UTE UTE UTE

+0.96

+1. 39

-0.22

+1. 44

+11. 23

-10.61

-11. 73

-0.22

+10.83

+1.12

-11. 80

-0.24

-0.39

-0.39

-0.39

-0.39

-0.39

-0.39

-0.39

+0.85

+1. 01

+1.16

-0.27

-0.23

-0.21

-0.77

-0.69

-0.28

-0.74

-0.23

-0.25

+1. 30

-0.25

-0.23

-0.24

-0.78

-0.24

-0.66

+0.54

-0.30

+0.66

-0.64

-0.28

+0.80

-0.29

-0.22

-0.24

+0.67

+0.71

-0.18

-0.33

-0.21

-0.17

+10.77

-0.12

-0.26

-0.19

-0.12

-0.26

+0.74

+1.20

-11. 99

-0.16

+6.98

+7.41

+12.26

+0.62

-0.17

-0.22

-0.23

-0.13

-0.23

-0.16

-0.21

-0.09 TO+26.7 TO+35.6 TO+44.4 TO+53.3 TO+62.2 TO+71.1 05/02/02 13:29:11 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG 014 014 014 014 UTE UTE 013 013 LTE LTE UTE UTE UTE UTE UTE UTE LTE LTE 013 013 UTE UTE UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS 013 013 013 013 014 014 UTE UTE UTE UTE UTE UTE 009 009 010 010 UTE UTE 009 009 UTE UTE UTE UTE 014 014 UTE UTE UTE UTE UTE UTE 009 009 UTE UTE 009 009 009 009 UTE UTE 007 007 010 010 UTE UTE 013 013 UTE UTE UTE UTE UTE UTE 009 009 009 009 UTE UTE UTE UTE UTE UTE UTE UTE 011 011 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 010 010 010 LTS LTS UTE UTE LTE LTE LTE LTE LTE LTE 008 008 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE CL WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 4100 4100 2038 4100 4100 4100 4100 2038 4100 4100 4100 2038 2015 2015 2015 2015 2015 2015 2015 4107 4107 4107 2015 2016 2016 4059 4059 2015 4062 2016 2016 4107 2015 2016 2015 4045 2016 4045 4045 2015 4045 4045 2015 4045 2015 2015 2015 4045 4045 2016 2015 2016 2016 4093 2037 2038 2038 2037 2038 4093 4093 4093 2037 4093 4093 4093 4093 2037 2038 2038 2037 2038 2037 2038 2037 OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET INLET OUTLET INLET INLET OUTLET INLET INLET INLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET Page 21 of 155 PROBE 46051 46051 460HR 460SI 460SI 460SI 460SI 460HR 46051 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 46051 460SI 460HR 460HR 460HR 46051 46051 460HR 460SI 460HR 460HR 460SI 460HR 460HR 460HR 460SI 460HR

'460SI 460SI 460HR 460SI 460SI 460HR 460SI 460HR 460HR 460HR 460SI 460SI 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 46051 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR

Framatome ANP Inc.

05/02/02 13:29:11 Customer Name: Oconee Unit 1 Component: S/G B Page 22 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

22 89 5.35 179 1 DNT LTE

+11.46 LTE LTE 4096 OUTLET 460SI 7.52 182 1 DNT UTE

-10.72 UTE UTE 4096 OUTLET 460S1 22 91 0.23 59 2

VOL 013

+1. 32 013 013 4096 OUTLET 460SI 0.49 78 2

VOL 014

+1.10 014 014 4096 OUTLET 460SI 5.05 173 1 DNT UTS

+12.84 UTS UT8 4096 OUTLET 46081 2.50 191 1 DNT UT8

+13.46 UT8 UT8 4096 OUTLET 46081 3.28 175 1 DNT LTE

+10.70 LTE LTE 4096 OUTLET 46081 3.38 189 1 DNT LTE

+10.75 LTE LTE 4096 OUTLET 46081 2.72 172 1 DNT LTE

+11.07 LTE LTE 4096 OUTLET 460S1 23 2

0.08 88 2

VOL 014

+1.10 014 014 4106 OUTLET 46081 0.75 66 P 3 TWD 14 011

-0.25 011 011 WAR 4059 OUTLET 46081 0.58 70 P 3 TWD 11 Oll

+0.69 Oll 011 WAR 4059 OUTLET 46081 3.57 23 2

TEA UTE

-0.31 UTE UTE 2015 INLET 460HR 23 3

0.58 112 P 3 TWO 11 010

+0.67 010 010 WAR 4059 OUTLET 46081 0.30 61 P 3 TWO 6 Oll

+0.69 011 Oll WAR 4059 OUTLET 46081 23 4

1. 48 15 2

TEA UTE

-0.27 UTE UTE 2015 INLET 460HR 23 12 0.09 67 2

VOL 001

+1. 01 001 001 4059 OUTLET 46081 2.30 20 2

TEA UTE

-0.24 UTE UTE 2016 INLET 460HR 23 15

1. 93 19 2

TEA UTE

-0.32 UTE UTE 2016 INLET 460HR 23 21 0.15 68 2

VOL 014

+1.19 014 014 4045 OUTLET 46081 23 23 0.63 0

P 3 TWD 11 009

-0.85 009 009 WAR 4045 OUTLET 46081 23 25 8.09 24 2

TEA UTE

-0.19 UTE UTE 2016 INLET 460HR 23 26 3.37 24 2

TEA UTE

-0.28 UTE UTE 2015 INLET 460HR 23 27 2.59 26 2

TEA UTE

-0.24 UTE UTE 2016 INLET 460HR 23 31 1.15 18 2

TEA UTE

-0.26 UTE UTE 2015 INLET 460HR 23 34 0.24 0

P 3 TWD 4 007

-0.17 007 007 WAR 4045 OUTLET 46081 23 36 4.55 23 2

TEA UTE

-0.25 UTE UTE 2016 INLET 460HR 23 37 0.45 0

P 3 TWD 8 007

-0.43 007 007 WAR 4045 OUTLET 46081 23 38 3.87 23 2

TEA UTE

-0.27 UTE UTE 2016 INLET 460HR 23 40 2.80 20 2

TEA UTE

-0.25 UTE UTE 2016 INLET 460HR 23 41 1.78 10 2

TEA UTE

-0.29 UTE UTE 2015 INLET 460HR 23 43

1. 75 18 2

TEA UTE

-0.27 UTE UTE 2015 INLET 460HR 23 44 2.20 13 1

DNT 001

+17.54 001 001 4041 OUTLET 46081 23 45 3.18 24 2

TEA UTE

-0.30 UTE UTE 2015 INLET 460HR 23 46 3.94 20 2

TEA UTE

-0.21 UTE UTE 2016 INLET 460HR 23 48

1. 55 21 2

TEA UTE

-0.21 UTE UTE 2037 INLET 460HR 23 50

~.63 22 2

TEA UTE

-0.13 UTE UTE 2037 INLET 460HR 23 51 1.72 20 2

TEA UTE

-0.37 UTE UTE 2038 INLET 460HR 23 58

1. 78 27 2

TEA UTE

-0.21 UTE UTE 2037 INLET 460HR 23 59 4.77 24 2

TEA UTE

-0.25 UTE UTE 2038 INLET 460HR 23 66 0.56 ll8 p 3 TWO 12 008

+0.63 008 008 WAR 4093 OUTLET 46081 23 69

1. 84 22 2

TEA UTE

-0.22 UTE UTE 2037 INLET 460HR 23 72 9.42 24 2

TEA UTE

-0.18 UTE UTE 2038 INLET 460HR 23 73 3.30 27 2

TEA UTE

-0.21 UTE UTE 2037 INLET 460HR 23 74 2.83 24 2

TEA UTE

-0.20 UTE UTE 2038 INLET 460HR 23 75 3.19 22 2

TEA UTE

-0.23 UTE UTE 2037 INLET 460HR 23 77 2.29 20 2

TEA UTE

-0.22 UTE UTE 2037 INLET 460HR 23 78

1. 60 24 2

TEA UTE

-0.16 UTE UTE 2038 INLET 460HR 23 81 0.54 110 P 3 TWD 9 010

-0.76 010 010 WAR 4096 OUTLET 46081 2.28 18 2

TEA UTE

-0.14 UTE UTE 2037 INLET 460HR 23 82 0.46 88 p 3 TWO 8 010

+0.67 010 010 WAR 4096 OUTLET 46081 23 84 0.22 132 2 VOL 015

+0.68 015 015 4096 OUTLET 46081 0.74 28 2

TEA UTE

-0.16 UTE UTE 2037 INLET 460HR 23 86

1. 90 16 2

TEA UTE

-0.26 UTE UTE 2037 INLET 460HR 23 87 3.17 22 2

TEA UTE

-0.33 UTE UTE 2038 INLET 460HR 23 88 3.20 24 2

TEA UTE

-0.14 UTE UTE 2037 INLET 460HR 23 90 6.00 175 1 DNT LTE

+10.95 LTE LTE 4096 OUTLET 46081

1. 92 177 1 DNT LTE

+11. 02 LTE LTE 4096 OUTLET 46081 5.42 170 1 DNT UTE

-10.50 UTE UTE 4096 OUTLET 46081 1.89 162 1 ONT UTE

-11.47 UTE UTE 4096 OUTLET 46081

1. 71 21 2

TEA UTE

-0.14 UTE UTE 2037 INLET 460HR 23 92 6.98 177 1 DNT LTE

+10.96 LTE LTE 4096 OUTLET 46081 3.70 190 1 DNT UTE

-11.91 UTE UTE 4096 OUTLET 46081 2.52 27 2

TEA UTE

-0.27 UTE UTE 2037 INLET 460HR 23 93 6.45 170 1 DNT LTE

+10.98 LTE LTE 4096 OUTLET 460SI 6.94 182 1 DNT UTE

-11. 75 UTE UTE 4096 OUTLET 460SI' 2.44 25 2

TEA UTE

-0.30 UTE UTE 2038 INLET 460HR 23 94

1. 99 25 2

TEA UTE

-0.22 UTE UTE 2038 INLET 460HR 24 1

0.09 116 2 VOL 004

+1.22 004 004 4059 OUTLET 46081 0.97 66 P 3 TWO 18 011

+0.65 011 011 WAR 4059 OUTLET 46081 4.89 24 2

TEA UTE

-0.18 UTE UTE 2019 INLET 460HR 24 2

0.66 103 P 3 TWO 12 Oll

+0.68 011 011 WAR 4059 OUTLET 46081 3.68 23 2

TEA UTE

-0.12 UTE UTE 2019 INLET 460HR 24 3

0.36 95 P 3 TWO 7 007

+0.47 007 007 WAR 4059 OUTLET 46081 0.12 142 2 VOL 009

+1. 03 009 009 4059 OUTLET 46081

Framatome ANP Inc.

05/02/02 13:29:12 Customer Name: Oconee Unit 1 Component: S/G B Page 23 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -. MRPC/PLUS POINT QUERY: QueryMI ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

0.60 47 2

TEA UTE

-0.22 UTE UTE 2020 INLET 460HR 24 4

4.01 174 1 DNT 015

+8.94 015 015 4106 OUTLET 460SI 3.42 26 2

TEA UTE

-0.10 UTE UTE 2019 INLET 460HR 24 5

0.19 18 2

TEA UTE

-0.26 UTE UTE 2020 INLET 460HR 24 6

0.48 90 P 3 TWD 9 010

+0.76 010 010 WAR 4059 OUTLET 460S1 3.72 24 2

TEA UTE

-0.26 UTE UTE 2015 INLET 460HR 24 7

1. 66 26 2

TEA UTE

-0.17 UTE UTE 2016 INLET 460HR 24 8

0.32 127 P 3 TWD 6 008

-0.07 008 008 WAR 4059 OUTLET 460SI 24 10 3.67 20 2

TEA UTE

-0.25 UTE UTE 2015 INLET 460HR 24 11 2.36 17 2

TEA UTE

-0.24 UTE UTS 2016 INLET 460HR

1. 83 28 P 1 SCI UTE

-0.31 UTE UTS CL 2016 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.31 TO+220.5 UTE UTS 2016 INLET 460HR 0.11 23 P 3 TWD 4 UTE

-0.31 TO+229.5 UTE UTS 2016 INLET 460HR 0.11 52 P 3 TWD 4 UTE

-0.31 TO+238.5 UTE UTS 2016 INLET 460HR 0.39 33 P 3 TWD 14 UTE

-0.31 TO+247.5 UTE UTS 2016 INLET 460HR 0.68 18 P 3 TWD 24 UTE

-0.31 TO+256.5 UTE UTS 2016 INLET 460HR

1. 27 24 P 3 TWD 45 UTE

-0.31 TO+265.5 UTE UTS 2016 INLET 460HR

1. 66 21 P 3 TWD 60 UTE

-0.31 TO+274.5 UTE UTS 2016 INLET 460HR 0.71 28 P 3 TWD 26 UTE

-0.31 TO+283.5 UTE UTS 2016 INLET 460HR 0.35 168 P 3 TWD 12 UTE

-0.31 TO+292.5 UTE UTS 2016 INLET 460HR 0.22 1

P 3 TWD 8 UTE

-0.31 TO+301. 5 UTE UTS 2016 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.31 TO+310.5 UTE UTS 2016 INLET 460HR 24 13 2.49 26 2

TEA UTE

-0.20 UTE UTE 2016 INLET 460HR 24 19 3.48 25 2

TEA UTE

-0.24 UTE UTE 2016 INLET 460HR 24 22 2.16 26 2

TEA UTE

-0.23 UTE UTE 2015 INLET 460HR 24 23 3.07 21 2

TEA UTE

-0.15 UTE UTE 2016 INLET 460HR 24 24 2.10 26 2

TEA UTE

-0.29 UTE UTE 2015 INLET 460HR 24 25

1. 78 18 2

TEA UTE

-0.20 UTE UTE 2016 INLET 460HR 24 26 0.48 0

P 3 TWD 8 009

-0.79 009 009 WAR 4041 OUTLET 460SI 24 29 0.38 0

P 3 TWD 7 010

-0.78 010 010 WAR 4041 OUTLET 460SI 4.30 21 2

TEA UTE

-0.24 UTE UTE 2016 INLET 460HR 24 30

1. 56 55 2

TEA UTE

-0.20 UTE UTE 2015 INLET 460HR 24 31 0.49 29 P 3 TWD 10 009

-0.76 009 009 WAR 4041 OUTLET 460SI 24 34 0.35 0

P 3 TWD 6 008

+0.45 008 008 WAR 4041 OUTLET 460SI 2.79 25 2

TEA UTE

-0.22 UTE UTE 2015 INLET 460HR 24 35 0.61 0

P 3 TWD 10 009

-0.78 009 009 WAR 4041 OUTLET 460S1 2.82 20 2

TEA UTE

-0.17 UTE UTE 2016 INLET 460HR 24 37 1.55 25 2

TEA UTE

-0.16 UTE UTE 2016 INLET 460HR 24 38 2.86 24 2

TEA UTE

-0.26 UTE UTE 2015 INLET 460HR 24 39 5.05 26 2

TEA UTE

-0.22 UTE UTE 2016 INLET 460HR 24 40 3.27 32 2

TEA UTE

-0.21 UTE UTE 2015 INLET 460HR 24 41 2.20 24 2

TEA UTE

-0.29 UTE UTE 2016 INLET 460HR 24 42 3.75 31 2

TEA UTE

-0.39 UTE UTE 2015 INLET 460HR 24 44 3.13 18 2

TEA UTE

-0.22 UTE UTE 2015 INLET 460HR 24 46 0.16 121 2 VOL 015

-0.99 015 015 4041 OUTLET 460SI 24 47 2.11 163 1 DNT 015

+11. 04 015 015 4041 OUTLET 460SI 24 48 4.65 23 2

TEA UTE

-0.25 UTE UTE 2037 INLET 460HR 24 49 3.51 21 2

TEA UTE

-0.21 UTE UTE 2037 INLET 460HR 24 52 2.99 21 2

TEA UTE

-0.22 UTE UTE 2037 INLET 460HR 24 54 4.27 24 2

TEA UTE

-0.18 UTE UTE 2037 INLET 460HR 24 55

1. 92 21 2

TEA UTE

-0.17 UTE UTE 2038 INLET 460HR 24 57 2.42 21 2

TEA UTE

-0.30 UTE UTE 2038 INLET 460HR 24 58

1. 95 24 2

TEA UTE

-0.19 UTE UTE 2037 INLET 460HR 24 65 2.49 23 2

TEA UTE

-0.17 UTE UTE 2038 INLET 460HR 24 68 0.54 93 P 3 TWD 11 008

+0.57 008 008 WAR 4094 OUTLET 460SI 24 73 0.10 82 2

VOL 012

+0.98 012 012 4094 OUTLET 460SI 0.76 25 2

TEA UTE

-0.18 UTE UTE 2038 INLET 460HR 24 74 2.15 23 2

TEA UTE

-0.14 UTE UTE 2037 INLET 460HR 24 76 3.05 26 2

TEA UTE

-0.16 UTE UTE 2037 INLET 460HR 24 77 2.86 21 2

TEA UTE

-0.24 UTE UTE 2038 INLET 460HR 24 78 2.50 30 2

TEA UTE

-0.27 UTE UTE 2037 INLET 460HR 24 79 2.24 23 2

TEA UTE

-0.18 UTE UTE 2038 INLET 460HR 24 80 3.32 89 P 3 TWD 42 010

-0.00 010 010 WAR 4096 OUTLET 460SI 2.74 24 2

TEA UTE

-0.21 UTE UTE 2037 INLET 460HR 24 81 0.22 96 P 3 TWD 5 010

-0.73 010 010 WAR 4096 OUTLET 460SI 2.77 22 2

TEA UTE

-0.26 UTE UTE 2038 INLET 460HR 24 82 2.33 23 2

TEA UTE

-0.15 UTE UTE 2037 INLET 460HR 24 83 3.18 28 2

TEA UTE

-0.27 UTE UTE 2038 INLET 460HR 24 84 3.16 27 2

TEA UTE

-0.24 UTE UTE 2037 INLET 460HR 24 87 2.31 21 2

TEA UTE

-0.17 UTE UTE 2037 INLET 460HR 24 89

1. 42 16 2

TEA UTE

-0.15 UTE UTE 2037 INLET 460HR 24 90

1. 03 19 2

TEA UTE

-0.19 UTE UTE 2038 INLET 460HR 24 92 8.48 179 1 DNT LTE

+10.88 LTE LTE 4096 OUTLET 460S1 0.37 91 P 3 TWD 9 014

+0.76 014 014 WAR 4096 OUTLET 460S1 5.60 177 1 DNT UTE

-11.36 UTE UTE 4096 OUTLET 460S1

Framatome ANP Inc.

05/02/02 13:29:12 Customer Name: Oconee Unit 1 Component: S/G B Page 24 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============

========::;

2.53 22 2

TEA UTE

-0.13 UTE UTE 2037 INLET 460HR 24 93 2.30 19 2

TEA UTE

-0.24 UTE UTE 2037 INLET 460HR 24 94 2.44 30 2

TEA UTE

-0.26 UTE UTE 2037 INLET 460HR 24 95 4.17 26 2

TEA UTE

-0.24 UTE UTE 2038 INLET 460HR 25 1

0.90 25 2

TEA UTE

-0.31 UTE UTE 2079 INLET 460HR 25 3

2.32 19 2

TEA UTE

-0.14 UTE UTE 2019 INLET 460HR 25 6

0.27 28 2

TEA UTE

-0.24 UTE UTE 2020 INLET 460HR 25 8

2.84 22 2

TEA UTE

-0.25 UTE UTE 2016 INLET 460HR 25 10 2.88 22 2

TEA UTE

-0.23 UTE UTE 2016 INLET 460HR 25 12 3.73 25 2

TEA UTE

-0.26 UTE UTE 2016 INLET 460HR 25 13

1. 75 26 2

TEA UTE

-0.33 UTE UTE 2015 INLET 460HR 25 16 0.22 100 2 VOL 004

+0.87 004 004 4059 OUTLET 460S1 25 17 2.05 21 2

TEA UTE

-0.23 UTE UTE 2015 INLET 460HR 25 18

1. 74 24 2

TEA UTE

-0.24 UTE UTE 2016 INLET 460HR 25 20 2.49 18 2

TEA UTE

-0.24 UTE UTE 2016 INLET 460HR 25 21 2.12 20 2

TEA UTE

-0.31 UTE UTE 2015 INLET 460HR 25 22 0.18 77 2

VOL 014

+1.10 014 014 4041 OUTLET 460S1 25 23 4.45 189 1 DNT LTS

-4.73 LTS LTS 4041 OUTLET 460SI 1.52 8

2 TEA UTE

-0.27 UTE UTE 2015 INLET 460HR 25 24 1.76, 21 2

TEA UTE

-0.22 UTE UTE 2016 INLET 460HR 25 25 2.46 23 2

TEA UTE

-0.27 UTE UTE 2015 INLET 460HR 25 27 2.18 23 2

TEA UTE

-0.24 UTE UTE 2015 INLET 460HR 25 29

1. 94 29 2

TEA UTE

-0.22 UTE UTE 2015 INLET 460HR 25 32 0.64 0

P 3 TWO 11 009

-0.66 009 009 WAR 4041 OUTLET 460S1 1.26 15 2

TEA UTE

-0.22 UTE UTE 2016 INLET 460HR 25 35 0.55 0

P 3 TWO 10 007

-0.32 007 007 WAR 4041 OUTLET 460S1 25 38 0.94 19 2

TEA.

UTE

-0.22 UTE UTE 2016 INLET 460HR 25 39 2.03 358 1 DNT UTE

-8.60 UTE UTE 4106 OUTLET 460S1

1. 78 33 1

VOL UTS

-17.10 UTS UTS 4041 OUTLET 460S1 2.13 18 2

TEA UTE

-0.23 UTE UTE 2015 INLET 460HR 25 40 0.17 91 2

SAl 014

+5.35 014 014 4041 OUTLET 460S1 0.17 91 2

TWO 31 014

+5.35 014 014 4041 OUTLET 460S1 0.17 96 2

SAl 014

+6.47 014 014 4041 OUTLET 460SI 0.17 96 2

TWO 19 014

+6.47 014 014 4041 OUTLET 460SI 25 42 0.57 29 2

TEA UTE

-0.20 UTE UTE 2020 INLET 460HR 25 45 2.16 18 2

TEA UTE

-0.14 UTE UTE 2078 INLET 460HR 25 46 0.60 17 2

TEA UTE

-0.20 UTE UTE 2020 INLET 460HR 25 47 1.02 21 2

TEA UTE

-0.17 UTE UTE 2019 INLET 460HR 25 52 4.19 27 2

TEA UTE

-0.21 UTE UTE 2037 INLET 460HR 25 57

1. 75 20 2

TEA UTE

-0.21 UTE UTE 2038 INLET 460HR 25 59 3.46 26 2

TEA UTE

-0.30 UTE UTE 2038 INLET 460HR 25 60 1.22 21 2

TEA UTE

-0.21 UTE UTE 2037 INLET 460HR 25 64 3.11 20 2

TEA UTE

-0.26 UTE UTE 2037 INLET 460HR 25 66 3.39 22 2

TEA UTE

-0.11 UTE UTE 2037 INLET 460HR 25 67 3.49 25 2

TEA UTE

-0.24 UTE UTE 2038 INLET 460HR 25 68 1.10 178 1 DNT 008

-17.64 008 008 4094 OUTLET 460SI 0.21 164 P 3 TWO 4 008

+0.43 008 008 WAR 4094 OUTLET 460S1 4.14 25 2

TEA UTE

-0.26 UTE UTE 2037 INLET 460HR 25 69 2.52 18 2

TEA UTE

-0.24 UTE UTE 2038 INLET 460HR 25 71 4.10 25 2

TEA UTE

-0.18 UTE UTE 2038 INLET 460HR 25 73 0.75 25 2

TEA UTE

-0.20 UTE UTE 2038 INLET 460HR 25 75 0.29 78 P 3 TWO 6 011

-0.76 011 011 WAR 4094 OUTLET 460S1 0.44 68 P 3 TWO 9 013

-0.75 013 013 WAR 4094 OUTLET 460S1 1.17 18 2

TEA UTE

-0.15 UTE UTE 2038 INLET 460HR 25 79 2.99 18 2

TEA UTE

-0.30 UTE UTE 2038 INLET 460HR 25 82 0.41 56 P 3 TWO 8 008

+0.76 008 008 WAR 4098 OUTLET 460SI 25 83 0.88 34 P 3 TWO 17 010

-0.70 010 010 WAR 4098 OUTLET 460SI 2.15 22 2

TEA UTE

-0.22 UTE UTE 2038 INLET 460HR 25 84

1. 01 2

1 DNT 003

-16.77 003 003 4098 OUTLET 460SI 0.54 94 P 3 TWO 11 008

-0.37 008 008 WAR 4098 OUTLET 460SI 1.82 18 2

TEA UTE

-0.23 UTE UTE 2037 INLET 460HR 25 85 5.01 25 P 1 SCI UTE

-0.20 UTE UTS CL/CS 2075 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.20 TO+180.0 UTE UTS 2075 INLET 460HR

1. 36 18 P 3 TWO 21 UTE

-0.20 TO+188.8 UTE UTS 2075 INLET 460HR 2.19 20 P 3 TWO 33 UTE

-0.20 TO+197.6 UTE UTS 2075 INLET 460HR 3.14 21 P 3 TWO 48 UTE

-0.20 TO+206.3 UTE UTS 2075 INLET 460HR 3.83 22 P 3 TWO 58 UTE

-0.20 TO+215.1 UTE UTS 2075 INLET 460HR 4.03 22 P 3 TWO 61 UTE

-0.20 TO+223.9 UTE UTS 2075 INLET 460HR 4.20 20 p 3 TWO 64 UTE

-0.20 TO+232.7 UTE UTS 2075 INLET 460HR 3.83 24 p 3 TWO 58 UTE

-0.20 TO+241.5 UTE UTS 2075 INLET 460HR 3.48 22 P 3 TWO 53 UTE

-0.20 TO+250.2 UTE UTS 2075 INLET 460HR 2.88 19 P 3 TWO 44 UTE

-0.20 TO+259.0 UTE UTS 2075 INLET 460HR

1. 84 17 P 3 TWO 28 UTE

-0.20 TO+267.8 UTE UTS 2075 INLET 460HR 1.72 12 P 3 TWO 26 UTE

-0.20 TO+276.6 UTE UTS 2075 INLET 460HR 1.21 18 P 3 TWO 18 UTE

-0.20 TO+285.4 UTE UTS 2075 INLET 460HR

Framatome ANP Inc.

05/02/02 13:29:12 Customer Name: Oconee Unit 1 Component: S/G B Page 25 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS - MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

0.00 0

P 3 TWO 0 UTE

-0.20 TO+294.1 UTE UTS 2075 INLET 460HR 25 90 3.75 21 2

TEA UTE

-0.24 UTE UTE 2037 INLET 460HR 25 93

1. 89 27 2

TEA UTE

-0.26 UTE UTE 2037 INLET 460HR 25 94 2.52 22 2

TEA UTE

-0.26 UTE UTE 2038 INLET 460HR 25 95 0.31 153 2 VOL 010

+0.62 010 010 4098 OUTLET 460S1 25 96 3.52 24 2

TEA UTE

-0.27 UTE UTE 2038 INLET 460HR 25 98 0.14 57 2

VOL LTE

+4.74 LTE LTS 4098 OUTLET 460SI 26 1

2.37 20 2

TEA UTE

-0.16 UTE UTE 2019 INLET 460HR 26 2

0.26 77 p 3 TWO 5 011

-0.53 011 011 WAR 4106 OUTLET 460S1 3.38 181 1 ONT 011

+17.71 011 011 4106 OUTLET 460S1 0.23 73 2

VOL 004

+0.76 004 004 4059 OUTLET 460SI 0.55 53 p 3 TWO 11 011

-0.73 011 011 WAR 4059 OUTLET 460SI 26 5

3.78 179 1 ONT 013

+5.43 013 013 4106 OUTLET 460S1 0.67 31 2

TEA UTE

-0.26 UTE UTE 2020 INLET 460HR 26 7

5.82 180 1 ONT UTE

-10.44 UTE UTE 4106 OUTLET 460S1 6.48 173 1 ONT LTE

+11.77 LTE LTE 4059 OUTLET 460S1 26 8

0.44 23 2

TEA UTE

-0.23 UTE UTE 2020 INLET 460HR 26 10 0.93 94 P 3 TWO 17 009

-0.77 009 009 WAR 4059 OUTLET 460SI 3.42 19 2

TEA UTE

-0.16 UTE UTE 2019 INLET 460HR 26 11 5.72 179 1 ONT UTE

-12.99 UTE U'l'E 4129 INLET 460SI 6.94 170 1 ONT LTE

+11. 81 LTE LTE 4059 OUTLET 460S1 0.53 24 2

SAl UTE

-3.67 UTE UTS 2020 INLET 460HR 0.51 23 2

TWO 50 UTE

-3.67 UTE UTS 2020 INLET 460HR 26 14 0.08 122 2 VOL 014

+1.13 014 014 4106 OUTLET 460S1 26 15 2.55 21 2

TEA UTE

-0.18 UTE UTE 2019 INLET 460HR 26 16 0.77 27 2

TEA UTE

-0.24 UTE UTE 2020 INLET 460HR 26 17 2.78 21 2

TEA UTE

-0.15 UTE UTE 2019 INLET 460HR 26 18 0.14 114 2 VOL 015

-0.94 015 015 4059 OUTLET 460S1 0.11 98 2

VOL 015

-2.74 015 015 4059 OUTLET 460S1 1.02 19 2

TEA UTE

-0.21 UTE UTE 2020 INLET 460HR 26 19 2.13 13 2

TEA UTE

-0.14 UTE UTE 2019 INLET 460HR 26 20

1. 08 20 2

TEA UTE

-0.24 UTE UTE 2020 INLET 460HR 26 21 3.22 28 2

TEA UTE

-0.20 UTE UTE 2019 INLET 460HR 26 22 0.38 27 2

TEA UTE

-0.24 UTE UTE 2020 INLET 460HR 26 24 0.53 27 2

TEA UTE

-0.24 UTE UTE 2020 INLET 460HR 26 25 3.26 20 2

TEA UTE

-0.13 UTE UTE 2019 INLET 460HR 26 26 0.54 29 2

TEA UTE

-0.28 UTE UTE 2020 INLET 460HR 26 27 6.61 25 2

TEA UTE

-0.13 UTE UTE 2019 INLET 460HR 26 29 0.10 65 2

VOL 014

+0.90 014 014 4106 OUTLET 460S1 2.48 26 2

TEA UTE

-0.27 UTE UTE 2015 INLET 460HR 26 31 3.10 28 2

TEA UTE

-0.28 UTE UTE 2015 INLET 460HR 26 32 3.43 19 2

TEA UTE

-0.19 UTE UTE 2016 INLET 460HR 26 34

1. 01 0

P 3 TWO 16 007

+0.46 007 007 WAR 4041 OUTLET 460SI 0.33 0

P 3 TWO 6 007

-0.32 007 007 WAR 4041 OUTLET 460SI 2.16 17 2

TEA UTE

-0.18 UTE UTE 2016 INLET 460HR 26 36 1.23 25 2

TEA UTE

-0.27 UTE UTE 2015 INLET 460HR 26 37 3.66 22 2

TEA UTE

-0.16 UTE UTE 2016 INLET 460HR 26 40 2.97 25 2

TEA UTE

-0.28 UTE UTE 2015 INLET 460HR 26 42 2.67 14 2

TEA UTE

-0.14 UTE UTE 2019 INLET 460HR 26 44

1. 55 31 2

TEA UTE

-0.28 UTE UTE 2019 INLET 460HR 26 46 0.49 28 2

TEA UTE

-0.24 UTE UTE 2020 INLET 460HR 26 48

1. 72 17 2

TEA UTE

-0.27 UTE UTE 2019 INLET 460HR 26 51 3.39 24 2

TEA UTE

-0.21 UTE UTE 2037 INLET 460HR 26 52 2.53 20 2

TEA UTE

-0.20 UTE UTE 2038 INLET 460HR 26 53 2.44 18 2

TEA UTE

-0.19 UTE UTE 2037 INLET 460HR 26 54

1. 95 22 2

TEA UTE

-0.23 UTE UTE 2038 INLET 460HR 26 56 4.80 178 1 ONT 004

-2.09 004 004 4094 OUTLET 460SI 26 60 0.10 98 2

VOL 010

+0.91 010 010 4094 OUTLET 460SI 26 61

1. 47 21 2

TEA UTE

-0.20 UTE UTE 2037 INLET 460HR 26 65 4.70 27 2

TEA UTE

-0.25 UTE UTE 2038 INLET 460HR 26 67 5.06 27 2

TEA UTE

-0.25 UTE UTE 2038 INLET 460HR 26 68 9.06 22 2

TEA UTE

-0.15 UTE UTE 2037 INLET 460HR 26 69

1. 31 25 2

TEA UTE

-0.23 UTE UTE 2038 INLET 460HR 26 70 3.07 30 2

TEA UTE

-0.19 UTE UTE 2037 INLET 460HR 26 71 5.86 26 2

TEA UTE

-0.21 UTE UTE 2038 INLET 460HR 26 73 3.55 21 2

TEA UTE

-0.18 UTE UTE 2038 INLET 460HR 26 75 3.45 24 2

TEA UTE

-0.16 UTE UTE 2038 INLET 460HR 26 77 0.12 161 P 3 TWO 2 007

+0.73 007 007 WAR 4094 OUTLET 460S1 4.25 25 2

TEA UTE

-0.18 UTE UTE 2038 INLET 460HR 26 78 2.35 23 2

TEA UTE

-0.24 UTE UTE 2037 INLET 460HR 26 79 4.93 25 2

TEA UTE

-0.22 UTE UTE 2038 INLET 460HR 26 80 2.36 19 2

TEA UTE

-0.21 UTE UTE 2037 INLET 460HR 26 81 2.24 22 2

TEA UTE

-0.18 UTE UTE 2038 INLET 460HR 26 83 3.27 27 2

TEA UTE

-0.23 UTE UTE 2037 INLET 460HR 26 84

1. 39 21 2

TEA UTE

-0.14 UTE UTE 2037 INLET-460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 26 26 26 26 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 85 86 87 98 1

2 3

5 6

10 11 12 15 16 17 18 20 22 25 26 31 32 33 36 40 41 42 46 47 52 53 56 57 58 60 61 64 65 67 69 70 72 73 75 77 78 79 80 82 83 84 85 0.67 1.90 0.20

1. 88 0.35 4.25 3.72 0.65 4.23 0.29 2.78 4.96 2.23 6.36 0.61 0.32 7.40 6.18 9.05 0.60 0.45 47.20 25.71 0.32 0.26 0.40 3.20 0.94 0.45 3.61 3.60
1. 21 0.43 2.43 1.21
1. 48 0.74 1.13 0.66 3.20 0.44
1. 30
1. 61 8.04 4.42 5.15 4.19 7.02 5.06 4.85 2.41 2.97 5.27 3.20 1.15 2.78 0.42 4.90 2.32 4.49 2.98 1.57 3.07 3.20 5.44 0.61 3.23 2.16 0.85 0.52 1.83 1.15 0.40 0.25 0.06 51 14 60 21 98 22 21 27 25 P 3 TWO 13 2

2 2

2 2

2 2

2 TEA VOL TEA VOL TEA TEA TEA TEA 3 TWO 6 TEA ONT ONT ONT TEA 3 TWO 6 ONT ONT ONT 32 P

27 2

1783 173 1 168 1 28 2

47 P

180 1 182 1 182 1 52 P 3 TWO 11 19 27 21 76 75 29 15 17 97 21 26 17 94 16 27 25 23 23 32 23 50 22 15 24 26 24 27 25 24 27 22 26 28 22 23 28 152 23 22 30 23 31 23 29 27 97 25 23 33 47 21 23 24 29 246 2

1 1

9 2

2 2

2 2

2 2

2 TEA MCI SCI PLP VOL TEA TEA TEA VOL TEA TEA TEA P 3 TWO 8 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA P 3 TWO 8 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA P 3 TWO 12 2

TEA P 1 SCI P 3 TWO 0 P 3 TWO 31 P 3 TWO 58 P 3 TWO 46 P 3 TWO 27 P 3 TWO 21 P 3 TWO 0 010 UTE 008 UTE 014 UTE UTE UTE UTE 009 UTE UTE LTE LTE UTE 009 UTE UTE LTE 009 UTE LTE LTE 014 014 UTE UTE UTE 004 UTE UTE UTE 007 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 UTE UTE UTE UTE UTE UTE UTE UTE 009 UTE UTE UTE UTE UTE UTE UTE UTE UTE

+0.75

-0.15

+0.45

-0.21

+1. 46

-0.20

-0.25

-0.30

-0.11

+0.04

-0.12

-11.31

+4.02

+11. 73

-0.24

-0.79

-11.53

-12.05

+11. 88

-0.68

-0.20

+2.10

+2.36

+1.11

+0.90

-0.18

-0.15

-0.23

+0.85

-0.18

-0.13

-0.19

-0.28

-0.14

-0.18

-0.18

-0.28'

-0.21

-0.19

-0.15

-0.19

-0.20

-0.19

-0.18

-0.22

-0.24

-0.22

-0.22

-0.31

-0.27

-0.38

-0.20

-0.21

-0.24

-0.09

-0.27

-0.76

-0.22

-0.21

-0.24

-0.24

-0.20

-0.28

-0.10

-0.24

-0.59

-0.18

-0.12

-0.12

-0.12

-0.12

-0.12

-0.12

-0.12

-0.12 TO+92.2 TO+83.4 TO+74.6 TO+65.9 TO+57.1 TO+48.3 TO+39.5 05/02/02 13:29:12 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG 010 010 UTE UTE 008 008 UTE UTE 014 014 UTE UTE UTE UTE UTE UTE UTE UTE 009 009 UTE UTE UTE UTE LTE LTE LTE LTE UTE UTE 009 009 UTE UTE UTE UTE LTE LTE 009 009 UTE UTE LTE LTE LTE LTE 014 014 014 014 UTE UTE UTE UTE UTE UTE 004 004 UTE UTE UTE UTE UTE UTE 007 007 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 009 UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS WAR WAR WAR WAR WAR WAR WAR CL 4098 2038 4098 2038 4098 2075 2079 2020 2019 4059 2019 4106 4059 4059 2020 4059 4126 4126 4059 4059 2020 705 705 4106 4106 2020 2019 2020 4059 2019 2019 2020 4059 2019 2020 2019 2020 2020 2020 2019 2020 2020 2019 2038 2043 2044 2043 2044 2044 2043 2044 2043 2043 2043 2044 2044 4094 2043 2043 2043 2044 2043 2044 2044 2043 4098 2044 2043 2043 2043 2043 2043 2043 2043 2043 OUTLET INLET OUTLET INLET OUTLET INLET INLET INLET INLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 26 of 155 PROBE 460SI 460HR 460SI 460HR 460SI 460HR 460HR 460HR 460HR 460S1 460HR 46081 46081 46081 460HR 460S1 52081 520S1 4608I 46081 460HR 380EX 380EX 46081 46081 460HR 460HR 460HR 460S1 460HR 460HR 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 46081 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR

Framatome ANP Inc.

05/02/02 13:29:13 Customer Name: Oconee Unit 1 Component: S/G B Page 27 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -_ MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
=::::;:=

27 86 0.81 27 2

TEA UTE

-0.13 UTE UTE 2044 INLET 460HR 27 87 2.19 25 2

TEA UTE

-0.23 UTE UTE 2043 INLET 460HR 27 88 5.84 178 1 DNT LTE

+11.41 LTE LTE 4098 OUTLET 460SI 0.51 70 P 3 TWD 10 009

-0.71 009 009 WAR 4098 OUTLET 460SI 0.34 54 2

VOL 014

+0.97 014 014 4098 OUTLET 460SI 6.03 177 1 DNT UTE

-11. 92 UTE UTE 4098 OUTLET 460SI 3.45 25 2

TEA UTE

-0.08 UTE UTE 2044 INLET 460HR 27 89 8.37 184 1 DNT LTE

+11.24 LTE LTE 4098 OUTLET 460SI 0.25 90 2

VOL 014

+1.26 014 014 4098 OUTLET 460SI 0.43 63 2

VOL 014

+0.77 014 014 4098 OUTLET 460SI

11. 00 183 1 DNT UTE

-11. 79 UTE UTE 4098 OUTLET 460SI

1. 90 21 2

TEA UTE

-0.19 UTE UTE 2043 INLET 460HR 27 90 8.27 180 1 DNT LTE

+11.23 LTE LTE 4098 OUTLET 460SI 0.13 116 2 VOL 014

+1.10 014 014 4098 OUTLET 460SI 3.82 25 2

TEA UTE

-0.25 UTE UTE 2044 INLET 460HR 27 92 3.67 29 2

TEA UTE

-0.24 UTE UTE 2043 INLET 460HR 27 93 2.77 26 2

TEA UTE

-0.24 UTE UTE 2044 INLET 460HR 27 94 2.00 20 2

TEA UTE

-0.25 UTE UTE 2043 INLET 460HR 27 96 2.90 23 2

TEA UTE

-0.25 UTE UTE 2043 INLET 460HR 27 97 2.00 27 2

TEA UTE

-0.17 UTE UTE 2044 INLET 460HR 27 99

1. 02 26 2

TEA UTE

-0.19 UTE UTE 2104 INLET 460HR 27 100

1. 81 14 2

TEA UTE

-0.13 UTE UTE 2105 INLET 460HR 28 1

1.10 26 2

TEA UTE

-0.19 UTE UTE 2020 INLET 460HR 28 2

0.98 30 2

TEA UTE

-0.17 UTE UTE 2020 INLET 460HR 28 4

0.12 85 2

VOL 014

+0.84 014 014 4106 OUTLET 460SI 28 5

2.74 35 2

TEA UTE

-0.19 UTE UTE 2019 INLET 460HR 28 6

0.45 59 P 3 TWD 9 010

-0.76 010 010 WAR 4059 OUTLET 460SI 0.99 21 2

TEA UTE

-0.18 UTE UTE 2020 INLET 460HR 28 7

7.32 182 1 DNT UTE

-11. 51 UTE UTE 4106 OUTLET 460SI 7.01 174 1 DNT LTE

+11.57 LTE LTE 4059 OUTLET 460SI 2.25 358 1 DNT LTE

+9.99 LTE LTE 4059 OUTLET 460SI 2.80 17 2

TEA UTE

-0.16 UTE UTE 2019 INLET 460HR 28 8

6.08 180 1 DNT UTE

-11. 55 UTE UTE 4106 OUTLET 460SI 7.44 175 1 DNT LTS

-13.31 LTS LTS 4059 OUTLET 460SI 2.77 178 1 DNT LTS

-11.75 LTS LTS 4059 OUTLET 460SI 28 12 7.64 181 1 DNT LTE

+10.17 LTE LTE 4106 OUTLET 460SI 6.94 171 1 DNT UTE

-11. 42 UTE UTE 4106 OUTLET 460SI 0.34 92 P 3 TWD 7 014

+0.74 014 014 WAR 4059 OUTLET 460SI 28 14 2.34 22 2

TEA UTE

-0.16 UTE UTE 2019 INLET 460HR 28 15 0.26 76 2

VOL 014

+1.14 014 014 4106 OUTLET 460SI 0.44 201 2 TEA UTE

-0.19 UTE UTE 2020 INLET 460HR 28 17 0.35 44 2

TEA UTE

-0.20 UTE UTE 2020 INLET 460HR 28 19 0.50 18 2

TEA UTE

-0.20 UTE UTE 2020 INLET 460HR 28 20

1. 60 17 2

TEA UTE

-0.20 UTE UTE 2019 INLET 460HR 28 21 1.11 22 2

TEA UTE

-0.18 UTE UTE 2020 INLET 460HR 28 22 2.49 24 2

TEA UTE

-0.16 UTE UTE 2019 INLET 460HR 28 23 0.55 22 2

TEA UTE

-0.13 UTE UTE 2020 INLET 460HR 28 25

1. 91 18 2

TEA UTE

-0.17 UTE UTE 2020 INLET 460HR 28 26 2.80 20 2

TEA UTE

-0.18 UTE UTE 2019 INLET 460HR 28 27 1.05 20 2

TEA UTE

-0.15 UTE UTE 2020 INLET 460HR 28 28 3.19 22 2

TEA UTE

-0.20 UTE UTE 2019 INLET 460HR 28 32 2.02 10 2

TEA UTE

-0.15 UTE UTE 2019 INLET 460HR 28 34 1.27 15 2

TEA UTE

-0.22 UTE UTE 2019 INLET 460HR 28 36 2.35 24 2

TEA UTE

-0.18 UTE UTE 2019 INLET 460HR 28 38 3.54 21 2

TEA UTE

-0.17 UTE UTE 2019 INLET 460HR 28 41 0.89 30 2

TEA UTE

-0.14 UTE UTE 2020 INLET 460HR 28 42 0.90 15 2

TEA UTE

-0.15 UTE UTE 2019 INLET 460HR 28 43 0.85 25 2

TEA UTE

-0.18 UTE UTE 2020 INLET 460HR 28 46 2.07 22 2

TEA UTE

-0.14 UTE UTE 2019 INLET 460HR 28 48 1.88 22 2

TEA UTE

-0.11 UTE UTE 2019 INLET 460HR 28 49 0.30 25 2

TEA UTE

-0.18 UTE UTE 2020 INLET 460HR 28 50 2.35 22 2

TEA UTE

-0.13 UTE UTE 2019 INLET 460HR 28 51 4.99 22 2

TEA UTE

-0.23 UTE UTE 2043 INLET 460HR 28 52 2.61 24 2

TEA UTE

-0.22 UTE UTE 2043 INLET 460HR 28 53 2.83 24 2

TEA UTE

-0.27 UTE UTE 2044 INLET 460HR 28 54 2.16 24 2

TEA UTE

-0.26 UTE UTE 2043 INLET 460HR 28 57 3.44 23 2

TEA UTE

-0.31 UTE UTE 2044 INLET 460HR 28 58

1. 77 21 2

TEA UTE

-0.22 UTE UTE 2043 INLET 460HR 28 59 3.48 21 2

TEA UTE

-0.15 UTE UTE 2044 INLET 460HR 28 61

1. 95 33 2

TEA UTE

-0.30 UTE UTE 2044 INLET 460HR 28 62 3.24 25 2

TEA UTE

-0.22 UTE UTE 2043 INLET 460HR 28 63 3.64 25 2

TEA UTE

-0.16 UTE UTE 2044 INLET 460HR 28 65

1. 58 15 2

TEA UTE

-0.33 UTE UTE 2044 INLET 460HR 28 68 4.08 31 2

TEA UTE

-0.21 UTE UTE 2043 INLET 460HR 28 69 4.13 26 2

TEA UTE

-0.20 UTE UTE 2044 INLET 460HR

Framatome ANP Inc.

05/02/02 13:29:13 Customer Name: Oconee Unit 1 Component: S/G B Page 28 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

28 78 2.99 24 2

TEA UTE

-0.20 UTE UTE 2044 INLET 460HR 28 80 7.45 27 P 1 SCI UTE

-0.20 UTE UTS CL 2075 INLET 460HR o.aO 0

P 3 TWO 0 UTE

-0.20 TO+215.1 UTE UTS 2075 INLET 460HR 1.25 27 P 3 TWO 16 UTE

-0.20 TO+223.9 UTE UTS 2075 INLET 460HR 2.49 28 P 3 TWO 33 UTE

-0.20 TO+232.7 UTE UTS 2075 INLET 460HR 4.27 27 P 3 TWO 56 UTE

-0.20 TO+241. 5 UTE UTS 2075 INLET 460HR 4.61 29 P 3 TWO 60 UTE

-0.20 TO+250.2 UTE UTS 2075 INLET 460HR 5.07 29 P 3 TWO 66 UTE

-0.20 TO+259.0 UTE UTS 2075 INLET 460HR 6.40 25 P 3 TWO 84 UTE

-0.20 TO+267.8 UTE UTS 2075 INLET 460HR 5.87 25 P 3 TWO 77 UTE

-0.20 TO+276.6 UTE UTS 2075 INLET 460HR 4.37 29 P 3 TWO 57 UTE

-0.20 TO+285.4 UTE UTS 2075 INLET 460HR 4.13 30 P 3 TWO 54 UTE

-0.20 TO+294.1 UTE UTS 2075 INLET 460HR 4.69 27 P 3 TWO 62 UTE

-0.20 TO+302.9 UTE UTS 2075 INLET 460HR 4.31 27 P 3 TWO 57 UTE

-0.20 TO+311.7 UTE UTS 2075 INLET 460HR 2.76 29 p 3 TWO 36 UTE

-0.20 TO+320.5 UTE UTS 2075 INLET 460HR 2.42 20 P 3 TWO 32 UTE

-0.20 TO+329.3 UTE UTS 2075 INLET 460HR 2.83 23 P 3 TWO 37 UTE

-0.20 TO+338.0 UTE UTS 2075 INLET 460HR 2.98 21 P 3 TWO 39 UTE

-0.20 TO+346.8 UTE UTS 2075 INLET 460HR 2.81 21 P 3 TWO 37 UTE

-0.20 TO+355.6 UTE UTS 2075 INLET 460HR 3.63 20 P 3 TWO 48 UTE

-0.20 TO+4.4 UTE UTS 2075 INLET 460HR 3.54 29 P 3 TWO 47 UTE

-0.20 TO+13.2 UTE UTS 2075 INLET 460HR 3.61 27 P 3 TWO 47 UTE

-0.20 TO+22.0 UTE UTS 2075 INLET 460HR 3.93 23 P 3 TWO 52 UTE

-0.20 TO+30.7 UTE UTS 2075 INLET 460HR 4.37 21 P 3 TWO 57 UTE

-0.20 TO+39.5 UTE UTS 2075 INLET 460HR 3.77 22 P 3 TWO 50 UTE

-0.20 TO+48.3 UTE UTS 2075 INLET 460HR 2.88 20 p 3 TWO 38 UTE

-0.20 TO+57.1 UTE UTS 2075 INLET 460HR

1. 70 23 p 3 TWO 22 UTE

-0.20 TO+65.9 UTE UTS 2075 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.20 TO+74.6 UTE UTS 2075 INLET 460HR 28 81 2.04 22 2

TEA UTE

-0.24 UTE UTE 2043 INLET 460HR 28 84 2.38 21 2

TEA UTE

-0.22 UTE UTE 2044 INLET 460HR 28 85 1.99 14 2

TEA UTE

-0.26 UTE UTE 2043 INLET 460HR 28 86 2.32 23 2

TEA UTE

-0.13 UTE UTE 2044 INLET 460HR 28 87 0.47 80 P 3 TWO 10 008

+0.51 008 008 WAR 4098 OUTLET 460SI 28 88 6.73 177 1 ONT LTE

+11. 20 LTE LTE 4098 OUTLET 460SI 7.14 183 1 ONT UTE

-11.46 UTE UTE 4098 OUTLET 460SI 28 92 0.38 101 P 3 TWO 8 011

-0.67 011 011 WAR 4098 OUTLET 460SI 28 95 1.53 20 2

TEA UTE

-0.18 UTE UTE 2044 INLET 460HR 28 96 3.75 34 2

TEA UTE

-0.25 UTE UTE 2043 INLET 460HR 28 97 2.86 21 2

TEA UTE

-0.19 UTE UTE 2044 INLET 460HR 28 98 3.46 20 2

TEA UTE

-0.21 UTE UTE 2043 INLET 460HR 28 99 0.18 71 2

VOL 013

+1. 47 013 013 4098 OUTLET 460SI 28 101 2.63 19 2

TEA UTE

-0.16 UTE UTE 2105 INLET 460HR 29 3

0.38 195 2 TEA UTE

-0.17 UTE UTE 2020 INLET 460HR 29 4

0.34 39 P 3 TWO 7 008

+0.02 008 008 WAR 4059 OUTLET 460SI 3.04 23 2

TEA UTE

-0.13 UTE UTE 2019 INLET 460HR 29 5

1. 63 50 1

VOL 002

+4.55 002 002 4059 OUTLET 460SI 0.48 125 P 3 TWO 9 010

+0.64 010 010 WAR 4059 OUTLET 460SI 1.04 22 2

TEA UTE

-0.22 UTE UTE 2020 INLET 460HR 29 6

2.96 19 2

TEA UTE

-0.21 UTE UTE 2019 INLET 460HR 29 7

0.71 22 2

TEA UTE

-0.21 UTE UTE 2020 INLET 460HR 29 8

2.00 173 1 DNT LTE

+5.48 LTE LTE 4059 OUTLET 460SI 29 9

0.48 47 P 3 TWO 9 009

-0.79 009 009 WAR 4059 OUTLET 460SI 29 11 0.30 140 p 3 TWO 6 009

-0.81 009 009 WAR 4059 OUTLET 460SI 1.08 28 2

TEA UTE

-0.24 UTE UTE 2020 INLET 460HR 29 12 2.32 21 2

TEA UTE

-0.15 UTE UTE 2019 INLET 460HR 29 13 0.78 22 2

TEA UTE

-0.16 UTE UTE 2020 INLET 460HR 29 15 0.56 24 2

TEA UTE

-0.18 UTE UTE 2020 INLET 460HR 29 17 0.34 21 2

TEA UTE

-0.30 UTE UTE 2020 INLET 460HR 29 18

1. 76 22 2

TEA UTE

-0.10 UTE UTE 2019 INLET 460HR 29 19 0.76 24 2

TEA UTE

-0.23 UTE UTE 2020 INLET 460HR 29 20 2.55 22 2

TEA UTE

-0.13 UTE UTE 2019 INLET 460HR 29 21 0.72 30 2

TEA UTE

-0.20 UTE UTE 2020 INLET 460HR 29 22 0.99 19 2

TEA UTE

-0.07 UTE UTE 2019 INLET 460HR 29 28 2.66 156 1 ONT LTE

+7.70 LTE LTE 4059 OUTLET 460SI 29 32

1. 40 23 2

TEA UTE

-0.11 UTE UTE 2019 INLET 460HR 29 33 0.80 19 2

TEA UTE

-0.20 UTE UTE 2020 INLET 460HR 29 34 3.64 19 2

TEA UTE

-0.10 UTE UTE 2019 INLET 460HR 29 38 1.85 180 1 ONT UTS

+3.63 UTS UTS 4106 OUTLET 460S1 29 40 5.13 176 1 ONT 011

-11.40 011 011 4106 OUTLET 460SI 0.37 81 2

VOL 014

+1. 01 014 014 4106 OUTLET 460SI 29 41 1.08 14 2

TEA UTE

-0.22 UTE UTE 2020 INLET 460HR 29 42 0.65 14 2

TEA UTE

-0.12 UTE UTE 2019 INLET 460HR 29 44 1.59 22 2

TEA UTE

-0.17 UTE UTE 2020 INLET 460HR 29 45 2.10 17 2

TEA UTE

-0.17 UTE UTE 2019 INLET 460HR 29 46 0.83 18 2

TEA UTE

-0.16 UTE UTE 2020 INLET 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 29 51 29 55 29 56 29 59 29 60 29 64 29 66 29 68 29 69 29 71 29 72 29 73 29 74 29 75 29 76 29 77 29 78 29 79 29 80 29 81 29 82 29 83 29 84 29 85 29 86 29 87 29 90 29 93 29 94 29 96 29 97 29 98 29 99 29 100 29 102 29 103 29 104 30 2

30 4

30 7

30 8

30 10 30 12 30 20 30 22 30 24 30 32 30 40 30 43 30 44 30 49 30 51 30 54 30 56 30 59 3.96 3.00

1. 78 3.86 4.09 4.02 4.44 0.40 2.57 4.51 3.22 3.68 2.93 5.99 2.11 3.85 0.36 0.39 0.35 0.09 3.07 3.11 0.67 3.10 0.67 3.62 2.88 3.22 0.48 0.23 0.45 4.60 3.55 3.98 3.22 5.21 5.82 2.44 4.44 0.27 3.21 2.06 2.09 2.72 0.07 0.35
1. 94 0.33 7.38 0.09 0.33 5.52 0.35 3.41 0.81 0.22 0.25 2.79 9.48 0.28 0.77 10.91 3.89 1.33 0.93 2.64 2.89 4.84 0.96 2.43
1. 54 2.21
1. 57
1. 57 2.76 24 2

TEA 25 2

TEA 22 2

TEA 24 2

TEA 23 2

TEA 28 2

TEA 22 2

TEA 43 2

VOL 22 2

TEA 30 2

TEA 21 2

TEA 22 2

TEA 20 2

TEA 27 2

TEA 16 2

TEA 29 2

TEA 127 P 3 TWO 7 28 2

VOL 41 2

VOL 74 2

VOL 20 2

TEA 23 2

TEA 85 P 3 TWO 15 23 2

TEA 98 P 3 TWO 15 27 2

TEA 24 2

TEA 23 2

TEA 89 P 3 TWO 11 48 P 3 TWO 5 73 P 3 TWO 9 24 2

TEA 25 2

TEA 27 2

TEA 177 1 ONT 168 1 ONT 175 1 ONT 22 2

TEA 26 2

TEA 116 P 3 TWO 6 22 2

TEA 27 2

TEA 27 2

TEA 25 2

TEA 70 2

VOL 65 P 3 TWO 7 25 2

TEA 44 P 3 TWO 7 180 1 ONT 94 2

VOL 149 2 VOL 23 2

TEA 89 P 3 TWO 7 18 2

TEA 24 2

TEA 129 P 3 TWO 4 140 P 3 TWO 5 172 1 ONT 177 1 ONT 57 P 3 TWO 5 64 P 3 TWO 14 185 1 DNT 21 2

TEA 29 2

TEA 14 2

TEA 17 2

TEA 19 2

TEA 21 2

TEA 30 2

TEA 18 2

TEA 164 P 3 ONT 23 2

TEA 20 2

MAl 20 2

TWD 59 18 2

TEA UTE UTE UTE UTE UTE UTE UTE LTS UTE UTE UTE UTE UTE UTE UTE UTE 008 UTE UTE UTE UTE UTE 008 UTE 008 UTE UTE UTE 009 008 008 UTE UTE UTE UTE UTE LTE UTE UTE 009 UTE UTE UTE UTE 013 010 UTE 007 010 015 015 UTE 010 UTE UTE 009 009 LTE LTE 009 010 UTS UTE UTE UTE UTE UTE UTE UTE UTE LTE UTE UTE UTE UTE

-0.16

-0.21

-0.19

-0.20

-0.25

-0.36

-0.15

+10.08

-0.22

-0.21

-0.18

-0.22

-0.28

-0.31

-0.35

-0.25

+0.40

-4.34

-5.08

-5.07

-0.13

-0.21

+0.69

-0.15

+0.68

-0.22

-0.25

-0.25

-0.76

-0.67

+0.73

-0.22

-0.16

-0.19

-12.35

-12.76

+10.90

-0.13

-0.19

-0.71

-0.24

-0.18

-0.25

-0.17

+1.42

+0.52

-0.20

-0.26

+0.65

-2.04

+0.73

-0.15

+0.61

-0.16

-0.23

-0.61

-0.62

+11. 02

+11. 82

-0.82

-0.67

+12.62

-0.13

-0.11

-0.16

-0.11

-0.17

-0.14

-0.22

-0.14

+5.40

-0.19

-3.58

-3.58

-0.22 05/02/02 13:29:13 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTS LTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 008 008 WAR UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 008 008 WAR UTE UTE 008 008 WAR UTE UTE UTE UTE UTE UTE 009 009 WAR 008 008 WAR 008 008 WAR UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE 009 009 WAR UTE UTE UTE UTE UTE UTE UTE UTE 013 013 010 010 WAR UTE UTE 007 007 WAR 010 010 015 015 015 015 UTE UTE 010 010 WAR UTE UTE UTE UTE 009 009 WAR 009 009 WAR LTE LTE LTE LTE 009 009 WAR 010 010 WAR UTS UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTS UTE UTS UTE UTE 2019 2043 2044 2043 2044 2044 2044 4094 2043 2043 2044 2043 2044 2043 2044 2043 4094 4094 4094 4094 2044 2043 4100 2044 4100 2043 2044 2043 4100 4098 4098 2043 2044 2043 4088 4088 4088 2044 2043 4098 2044 2043 2044 2043 4098 4098 2104 4098 4098 4098 4098 2105 4058 2019 2020 4106 4106 4059 4059 4059 4059 4059 2019 2019 2019 2019 2019 2019 2020 2019 4045 2075 2044 2044 2043 INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET Page 29 of 155 PROBE 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460S1 460S1 460SI 460HR 460HR 460SI 460HR 460SI 460HR 460HR 460HR 460S1 460S1 460S1 460HR 460HR 460HR 460SI 460SI 460SI 460HR 460HR 460S1 460HR 460HR 460HR 460HR 460S1 460S1 460HR 460S1 460S1 460S1 460S1 460HR 460SI 460HR 460HR 460S1 460SI 460SI 460S1 460SI 460SI 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460HR 460HR 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 61 69 71 74 75 78 80 81 82 83 84 86 87 88 89 90 91 96 98 100 101 103 104 2

3 4

7 8

9 11 12 16 17 18 19 22 23 25 28 47 49 54 55 58

1. 86 5.04
1. 50 2.45 4.54 0.86 0.72 3.89 2.22 2.60 2.94 0.00 0.55
1. 60 2.24 2.10
1. 70
1. 30 0.98 0.88 0.65 2.61 3.63 2.03 2.78 0.12 0.24 2.31 0.41
1. 85 0.00 0.36 0.57 1.18
1. 40 0.98 0.00 2.82
1. 82 2.10 0.56 3.91 0.20 0.38 6.49 2.03 0.48 2.36 0.77 0.63 0.17 2.53 0.42 5.11 6.66 3.42 0.68 6.81 2.04 0.41 0.28 0.82
1. 83 1.10 0.47 2.75 2.80 2.98
1. 92
1. 53 0.00 0.10 0.14 0.18 0.17 34 2

TEA UTE 31 2

TEA UTE 26 2

TEA UTE 20 2

TEA UTE 26 2

TEA UTE 15 2

TEA UTE 90 P 3 TWD 15 008 30 2

TEA UTE 25 2

TEA UTE 31 2

TEA UTE 23 P 1 SCI UTE o

P 3 TWD 0 UTE 45 P 3 TWD 14 UTE 18 P 3 TWD 51 UTE 18 P 3 TWD 88 UTE 17 P 3 TWD 78 UTE 19 P 3 TWD 55 UTE 20 P 3 TWD 38 UTE 31 P 3 TWD 27 UTE 41 P 3 TWD 23 UTE 46 P 3 TWD 0 UTE 26 2

TEA UTE 24 2

TEA UTE 19 2

TEA UTE 23 2

TEA UTE 99 2

VOL 014 157 P 3 TWD 5 014 22 2

TEA UTE 133 P 3 TWD 10 009 26 P 1 SCI UTE o

P 3 TWD 0 UTE 161 P 3 TWD 14 UTE 9

P 3 TWD 22 UTE 21 P 3 TWD 46 UTE 20 P 3 TWD 54 UTE 21 P 3 TWD 38 UTE o

P 3 TWD 0 UTE 24 2

TEA UTE 18 2

TEA UTE 29 2

TEA UTE 93 P 3 TWD 10 010 25 2

TEA UTE 23 2

VOL 012 80 P 3 TWD 8 010 178 1 DNT LTE 12 2

TEA UTE 202 2 TEA UTE 16 2

TEA UTE 177 2 DNT 004 149 P 3 TWD 13 009 47 2

VOL 014 15 2

TEA UTE 35 P 3 TWD 9 010 171 1 DNT LTE 175 1 DNT LTE 157 1 DNT LTE 80 P 3 TWD 14 009 176 1 DNT UTS 22 2

TEA

. UTE 19 2

TEA UTE 73 2

VOL 014 11 2

TEA UTE 32 2

TEA UTE 26 2

TEA UTE 21 2

TEA UTE 15 2

TEA UTE 21 2

TEA UTE 25 2

TEA UTE 23 2

TEA UTE 23 2

TEA UTE o

P 3 TWD 0 UTE 72 P 3 TWD 45 UTE 14 P 3 TWD 58 UTE 15 P 3 TWD 67 UTE 22 P 3 TWD 65 UTE

-0.21

-0.27

-0.23

-0.22

-0.27

-0.22

+0.68

-0.21

-0.24

-0.21

-0.38

-0.38

-0.38

-0.38

-0.38

-0.38

-0.38

-0.38

-0.38

-0.38

-0.38

-0.22

-0.24

-0.17

-0.25

+1.12

+0.77

-0.20

-0.47

-0.26

-0.26

-0.26

-0.26

-0.26

-0.26

-0.26

-0.26

-0.22

-0.25

-0.22

+0.75

-0.29

+0.87

+0.63

+5.88

-0.10

-0.19

-0.16

-1. 59

-0.64

+1. 09

-0.17

-0.70

+8.03

+10.96

+12.33

-0.66

+10.72

-0.12

-0.19

+1.00

-0.17

-0.17

-0.26

-0.25

-0.16

-0.13

-0.28

-0.25

-0.23

-3.71

-3.71

-3.71

-3.71

-3.71 TO+4.4 TO+355.6 TO+346.8 TO+338.0 TO+329.3 TO+320.5 TO+311. 7 TO+302.9 TO+294.1 TO+285.4 TO+188.8 TO+197.6 TO+206.3 TO+215.1 TO+223.9 TO+232.7 TO+241. 5 TO+311.7 TO+320.5 TO+329.3 TO+338.0 TO+346.8 05/02/02 13:29:13 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 008 008 UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE UTE UTE UTE UTE UTE UTE 014 014 014 014 UTE UTE 009 009 UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UrE UTS UTE UTE UTE UTE UTE UTE 010 010 UTE UTE 012 012 010 010 LTE LTE UTE UTE UTE UTE UTE UTE 004 004 009 009 014 014 UTE UTE 010 010 LTE LTE LTE LTE LTE LTE 009 009 UTS UTS UTE UTE UTE UTE 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS WAR CL WAR WAR CL/CS WAR WAR WAR WAR WAR 2043 2043 2043 2044 2043 2075 4100 2043 2044 2043 2044 2044 2044 2044 2044 2044 2044 2044 2044 2044 2044 2044 2043 2044 2043 4088 4088 2043 4100 2075 2075 2075 2075 2075 2075 2075 2075 2044 2043 2075 4096 2075 4107 4058 4052 2019 2020 2019 4052 4052 4052 2019 4052 4052 4052 4052 4052 4106 2019 2020 4052 2020 2019 2020 2020 2019 2027 2027 2043 2075 2043 2043 2043 2043 2043 INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 30 of 155 PROBE 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460S1 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460S1 460S1 460S1 460HR 460HR 460HR 460S1 460S1 460S1 460HR 460S1 460S1 460S1 460S1 460S1 460S1 460HR 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 60 64 66 68 69 73 75 76 77 78 79 80 82 84 86 87 91 96 100 101 104 105 106 1

3 5

6 8

9 10 11 12 15 17 20 23 29 32 37 38 39 41 42 44 48 50 52 55 56 0.13 0.00 0.35 3.50

1. 96 1.37 3.79 0.93 3.91 3.73 3.01 3.70 1.86 2.17 1.85 3.20
1. 44 0.84
1. 77 0.36 3.10
1. 75 0.81 0.81 1.59 1.85 4.52 0.27 0.45
1. 02
1. 49 0.84 0.29 0.78 2.48 0.14 0.48 0.36 0.24 0.42 2.86 0.26 2.50 0.94 2.69 0.43 4.17 0.52 3.76 4.96 6.91 10.21 3.72 2.46 0.61 1.55
1. 65 1.08 2.00
1. 67
1. 41
1. 78 2.82 2.09 5.24 3.12 0.26 0.15
1. 44 2.63
1. 33 0.31 0.36 4.75
1. 57 59 o

22 22 173 22 26 15 25 22 29 22 199 18 27 26 24 23 25 37 36 25 25 25 58 16 22 18 17 14 14 19 41 105 18 82 114 109 155 109 19 83 25 53 P 3 TWO 55 P 3 TWO 0 P 1 SCI 2

TEA 1

ONT 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA P 3 TWO 8 2

TEA 2

TEA 2

SAl 2

TWO 78 P 3 TWO 17 P 1 SCI 2

TEA P 3 P 3 P 3 P 3 P 3 P 3 P 3 2

P 3 P 3 P 3 P 3 P 3 2

2 2

TWO 0 TWO 21 32 39 29 o

13 TWO TWO TWO TWO TWO TEA TWO 3 12 9

4 10 TWO TWO TWO TWO TEA VOL TEA P 3 TWO 21 2

TEA 15 161 178 89 P

185 1 350 1 166 1 172 1 24 2

21 2

19 2

33 P

18 2

20 2

13 2

190 1 24 2

193 1 17 2

20 2

25 P 3 TWO 9 1

ONT 2

3 TWO 10 ONT ONT ONT ONT TEA TEA TEA 1 TEA TEA TEA TEA ONT TEA ONT TEA TEA TEA SCI 28 172 7

29 28 36 43 24 26 23 P 1 P 3 P 3 P 3 P 3 P 3 P 3 P 3 2

2 TWO 0 23 71 95 68 33 o

TWO TWO TWO TWO TWO TWO TEA TEA UTE UTE UTE UTE 001 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 UTE UTE UTE UTE 009 UTE UTE UTE UTE UTE UTE UTE UTE 010 UTE 010 010 010 014 010 UTE 014 UTE 009 UTE 008 013 009 LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE

-3.71

-3.71

-3.71

-0.19

-10.26

-0.31

-0.26

-0.20

-0.15

-0.17

-0.21

-0.29

-0.25

-0.24

-0.18

-0.18

-0.17

-0.20

-0.27

+0.68

-0.15

-0.17

-4.37

-4.37

+0.61

-0.24

-0.15

-0.24

-0.24

-0.24

-0.24

-0.24

-0.24

+0.75

-0.17

+0.56

-0.48

+0.59

+0.72

+0.55

-0.23

+1. 04

-0.19

-0.50

-0.17

+0.62

+18.24

-0.75

+8.13

+10.92

+11.13

-9.84

-0.20

-0.21

-0.17

-0.10

-0.15

-0.14

-0.17

-3.74

-0.19

+10.02

-0.15

-0.24

-0.16

-0.33

-0.33

-0.33

-0.33

-0.33

-0.33

-0.33

-0.33

-0.21

-0.14 TO+355.6 TO+4.4 TO+231.1 TO+222.2 TO+213.3 TO+204.4 TO+195.6 TO+186.7 TO+298.5 TO+307.3 TO+316.1 TO+324.9 TO+333.7 TO+342.4 TO+351. 2 05/02/02 13:29:14 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTS UTE UTS UTE UTS UTE UTE 001 001 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 009 UTE UTE UTE UTE UTE UTS UTE UTS 009 009 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 010 UTE UTE 010 010 010 010 010 010 014 014 010 010 UTE UTE 014 014 UTE UTE 009 009 UTE UTE 008 008 013 013 009 009 LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTS UTE UTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE UTE UTE WAR WAR CL WAR WAR WAR WAR WAR WAR WAR WAR WAR CL 2043 2043 2043 2043 4094 2043 2043 2043 2043 2043 2043 2045 2046 2045 2046 2046 2046 2046 2045 4088 2046 2045 2046 2046 4088 2105 2105 2105 2105 2105 2105 2105 2105 4096 2105 4050 4050 4050 4050 4050 2028 4050 2027 4050 2027 4052 4052 4052 4052 4052 4052 4052 2028 2027 2020 2020 2019 2020 2019 4045 2020 4045 2019 2027 2027 2078 2078 2078 2078 2078 2078 2078 2078 2045 2045 INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 31 of 155 PROBE 460HR 460HR 460HR 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460HR 460HR 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460S1 460S1 460S1 460S1 460S1 460HR 460S1 460HR 460S1 460HR 460S1 460S1 460S1 460S1 460S1 460S1 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 33 33 33 33 33 33 33 33 33 33 33 57 61 63 64 67 70 71 74 76 77 79 82 83 85 87 89 90 92 93 96 100 103 104 105 106 107 1

2 3

4 5

6 9

10 11 12 15 5.51 2.89 3.43 4.50 2.42 9.93 2.05 3.20 2.42

1. 41 2.96 1.72 0.69 3.79
1. 47 2.53 2.77 0.11 0.34 0.25 0.28 1.00 0.53 0.14 0.16 0.25 0.22 0.15 0.13 1.21
1. 56 4.14 3.37 0.17 2.14 0.22 3.10 1.01 0.00 0.26 0.50 0.68 0.70
1. 07
1. 31 0.63 0.21 0.00
1. 94 0.62 0.78 4.22 2.66 0.24 3.71 1.50 2.98 2.44 0.47 0.30 0.28 0.14 3.69 6.29 3.39 0.87 0.15 2.18 3.14 3.91 1.12 8.00 5.90 9.67 3.66 25 31 23 23 24 24 29 22 19 22 18 19 22 22 26 26 32 42 24 26 34 29 36 44 27 30 34 202 18 29 20 28 35 83 28 109 22 35 o

37 32 25 20 23 21 10 325 o

30 115 93 19 16 80 181 28 187 13 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 1 2

2 2

2 2

TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TWO 0 57 49 52 98 71 37 39 49 46 o

35 TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO SCI TEA TEA TEA VOL TEA P 3 TWO 5 2

TEA P 1 SCI P 3 TWO 0 P 3 TWO 12 P 3 TWO 23 P 3 TWO 31 P 3 TWO 32 P 3 TWO 49 P 3 TWO 60 P 3 TWO 29 P 3 TWO 10 P 3 TWO 0 2

TEA P 3 TWO 11 P 3 TWO 13 2

TEA 2

TEA 2

VOL 1

ONT 2

TEA 1

ONT 2

TEA TWO 12 TWO 7 TWO 7 TWO 3 TEA ONT ONT 3 TWO 20 VOL 79 P 3 107 P 3 138 P 3 168 P 3 17 2

176 1 170 1 96 P

62 2

31 2

20 2

21 2

19 2

25 2

185 1 181 1 TEA TEA TEA TEA TEA ONT ONT 183 1 ONT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 UTE 008 U"I:E UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 010 UTE UTE 004 010 UTE 010 UTE 008 010 010 012 UTE UTE LTE 010 014 UTE UTE UTE UTE UTE UTE LTE LTE

-0.15

-0.17

-0.16

-0.17

-0.18

-0.16

-0.19

-0.23

-0.20

-0.17

-0.24

-0.27

-0.17

-0.20

-0.25

-0.28

-0.18

-0.18

-0.18

-0.18

-0.18

-0.18

-0.18

-0.18

-0.18

-0.18

-0.18

-0.18

-0.18

-0.18

-0.19

-0.24

-0.23

+1. 03

-0.20

+0.52

-0.26

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.23

-0.54

-0.21

-0.18

-0.24

+0.64

+0.59

-0.27

+0.71

-0.34

+0.47

+0.20

+0.62

+0.71

-0.26

-11. 93

+10.59

+0.58

+1.21

-0.22

-0.30

-0.19

-0.22

-0.18

-10.71

+10.04

+11.47 TO+149.3 TO+166.8 TO+175.6 TO+184.4 TO+193.2 TO+202.0 TO+210.7 TO+219.5 TO+228.3 TO+237.1 TO+245.9 TO+158.0 TO+99.0 TO+108.0 TO+117.0 TO+126.0 TO+135.0 TO+144.0 TO+153.0 TO+162.0 TO+171.0 TO+180.0 05/02/02 13:29:14 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE U'l'E UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 014 UTE UTE 008 008 UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE 010 010 010 010 UTE UTE UTE UTE 004 004 010 010 UTE UTE 010 010 UTE UTE 008 008 010 010 010 010 012 012 UTE UTE UTE UTE LTE LTE 010 010 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE CL WAR CL WAR WAR WAR WAR WAR WAR WAR 2046 2046 2046 2045 2046 2045 2046 2045 2045 2045 2045 2046 2045 2045 2045 2045 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2045 2045 2046 4088 2045 4088 2046 2104 2104 2104 2104 2104 2104 2104 2104 2104 2104 2104 2075 4096 4096 2105 2028 4050 4050 2027 4050 2028 4050 4050 4050 4050 2028 4126 4050 4050 4050 2027 2028 2027 2028 2027 4106 4050 4050 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET OUTLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET Page 32 of 155 PROBE 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460HR 460HR 460SI 460SI 460HR 460SI 460HR 460SI 460SI 460SI 460SI 460HR 520SI 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 17 18 19 20 22 24 25 26 29 31 34 35 40 42 46 55 56 59 60 61 64 65 66 68 70 71 73 87 88 89 90 92 94 95 96 98 99 100 101 103 105 106 107 1

2 4

5 8

9 10 11 12 14 15 18 20 21 23 25 28 38 40 44 3.00 2.31 3.12

1. 93 1.28 2.38 3.49 3.40 0.15
1. 41 2.33 0.27 1.53 0.89 4.96 7.21 1.88 2.13 4.18 4.03 3.40 3.59 4.47 2.99 1.92 3.15 3.26 5.55 2.53 4.77 3.16 7.59 1.32 2.88 0.69 0.20
1. 58 2.86 3.72 3.46 2.29 0.81 2.80 2.41 4.71 2.76 3.24 2.03 4.65 5.73 0.11 3.06 0.41 2.94 3.63 9.18 4.11 4.03 2.96 0.28 9.15 7.64
1. 96 2.94 3.72 0.22 3.60 2.78 3.56 3.04
1. 68
1. 93
1. 78 2.96 2.65 19 20 21 17 24 19 21 26 68 25 33 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA P 3 TWD 3 2

TEA 2

TEA o

P 13 2

24 2

25 2

182 1 20 2

18 2

26 2

22 2

27 2

25 2

25 2

26 2

26 2

26 2

21 2

27 2

20 2

24 2

26 2

29 2

31 2

29 2

36 2

57 2

15 2

27 2

28 2

16 2

19 2

131 P 30 2

28 2

169 1 25 2

23 2

26 2

18 2

175 1 77 2

23 2

45 P

28 2

177 1 184 1 23 2

20 2

20 2

82 P

180 1 167 1 16 2

17 2

20 2

81 2

24 2

15 2

192 1 15 2

29 2

25 2

173 1 178 1 14 2

3 TWD 5 TEA TEA TEA DNT TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA VOL TEA TEA TEA TEA TEA 3 TWD 9 TEA TEA DNT TEA TEA TEA TEA DNT VOL TEA 3 TWD 10 TEA DNT DNT TEA TEA TEA 3 TWD 7 DNT DNT TEA TEA TEA VOL TEA TEA DNT TEA TEA TEA DNT DNT TEA UTE UTE UTE UTE UTE UTE UTE UTE 010 UTE UTE 007 UTE UTE UTE 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 UTE UTE UTE UTE UTE 014 UTE UTE 009 UTE UTE UTE UTE 010 012 UTE 010 UTE LTE UTS UTE UTE UTE 009 LTE LTE UTE UTE UTE 011 UTE UTE 007 UTE UTE UTE UTE UTE UTE

-0.30

-0.20

-0.19

-0.18

-0.16

-0.15

-0.23

-0.21

-0.70

-0.33

-0.28

+0.30

-0.40

-0.31

-0.22

+13.01

-0.33

-0.20

-0.24

-0.18

-0.21

-0.19

-0.22

-0.11

-0.18

-0.19

-0.13

-0.20

-0.19

-0.24

-0.24

-0.23

-0.16

-0.25

-0.26

+1.23

-0.18

-0.18

-0.18

-0.22

-0.19

+0.76

-0.24

-0.22

+0.01

-0.20

-0.12

-0.22

-0.24

+0.23

+1.25

-0.20

-0.42

-0.24

+10.46

+11. 09

-0.24

-0.29

-0.14

-0.65

+3.03

+4.17

-0.21

-0.19

-0.32

+1.28

-0.15

-0.21

-15.52

-0.18

-0.23

-0.28

-1. 99

-4.79

-0.16 05/02/02 13:29:14 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 010 WAR UTE UTE UTE UTE 007 007 WAR UTE UTE UTE UTE UTE UTE 010 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 014 WAR UTE UTE UTE UTE 009 009 UTE UTE UTE UTE UTE UTE UTE UTE 010 010 012 012 UTE UTE 010 010 WAR UTE UTE LTE LTE UTS UTS UTE UTE UTE UTE UTE UTE 009 009 WAR LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE 011 011 UTE UTE UTE UTE 007 007 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 2028 2028 2027 2028 2027 2027 2027 2028 4050 2028 2032 4041 2032 2031 2031 4041 2032 2045 2046 2045 2046 2045 2046 2045 2046 2046 2046 2045 2045 2045 2046 2045 2046 2045 2045 4088 2046 2045 2045 2046 2045 4088 2046 2045 4088 2075 2104 2075 2032 4050 4050 2031 4050 2031 4050 4050 2031 2032 2031 4050 4106 4106 2031 2031 2032 4050 2031 2031 4041 2031 2031 2032 4041 4041 2031 INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET OUTLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET INLET INLET OUTLET INLET INLET INLET OUTLET OUTLET INLET Page 33 of 155 PROBE 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460S1 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460S1 460S1 460HR 460S1 460HR 460S1 460S1 460HR 460HR 460HR 460S1 460S1 460S1 460HR 460HR 460HR 460S1 460HR 460HR 460S1 460HR 460HR 460HR 460SI 460SI 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 35 49 52 59 60 62 64 65 66 67 70 73 74 75 76 78 80 82 83 90 92 93 96 97 101 102 103 105 107 1

1. 08 0.00 0.29 0.51 0.40 0.30 0.00 3.43 1.20 2.78 0.17 0.51 0.23 1.17
1. 63 0.89 0.17 0.15 0.13 0.30 0.54 0.41 0.22 0.18 0.79 0.18 0.26 0.32 0.24 0.29 0.35 0.34 0.42 0.28
1. 65 2.16 2.69 0.69 2.98 4.06 4.22 7.06 3.69 4.22 4.05 3.44 7.76 3.87 3.81 7.84 2.97 7.39 10.36 2.31 6.58 4.02 3.55 2.67
1. 80 3.44 2.64 5.56 5.24 4.65 0.59 0.46 3.33 2.41 2.46 7.14 5.22 0.09 0.73
1. 56 3.51 43 o

28 21 29 34 o

22 16 17 99 39 33 16 19 20 170 11 173 26 3

17 21 20 5

45 22 24 49 27 41 26 26 5

23 23 23 73 21 27 185 25 26 20 24 25 27 23 21 29 173 174 183 28 176 180 179 24 25 27 29 178 177 178 82 66 177 31 27 174 27 120 113 20 24 P 1 SCI P 3 TWO 0 P 3 TWO 54 P 3 TWO 93 P 3 TWO 73 P 3 TWO 54 P 3 TWO 0 2

TEA 2

TEA 2

TEA 2

VOL 2

VOL P 3 TWD 24 P 3 TWO 53 P 3 TWO 63 P 3 TWO 46 P 3 TWD 20 P 3 TWD 19 P 3 TWO 18 P 3 TWO 27 P 3 TWO 36 P 3 TWO 31 P 3 TWO 23 P 3 TWO 0 P 3 TWO 44 P 3 TWO 0 P 3 TWO 25 P 3 TWO 28 P 3 TWO 24 P 3 TWO 26 P 3 TWO 29 P 3 TWO 29 P 3 TWO 32 P 3 TWO 26 P 1 8CI 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 1

ONT 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 1

DNT 1

ONT 1

ONT 2

TEA 1

ONT 1

ONT 1

ONT 2

TEA 2

TEA 2

TEA 2

TEA 1

ONT 1

ONT 1

ONT 2

VOL P 3 TWO 10 1

ONT 2

TEA 2

TEA 1

ONT 2

TEA 2

VOL P 3 TWO 14 2

TEA 2

TEA UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 003 013 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 005 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE UTE UTE LTE LTE UTE UTE UTE UTE UTE UTE UTE 014 009 LTE UTE UTE 009 UTE 008 010 UTE UTE

-0.23

-0.23

-0.23

-0.23

-0.23

-0.23

-0.23

-0.26

-0.27

-0.15

-15.41

+8.37

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.29

-0.22

-0.26

-0.10

-0.18

-0.19

+18.94

-0.20

-0.18

-0.19

-0.15

-0.32

-0.30

-0.20

-0.20

-0.25

-10.71

-11.51

+10.81

-0.22

-11.21

+10.78

+11.44

-0.18

-0.18

-0.17

-0.23

-12.00

-12.39

-12.67

+1. 38

-0.68

+11.28

-0.19

-0.16

-0.22

-0.22

+1.08

+0.74

-0.18

-0.21 TO+175.6 TO+184.4 TO+l93.2 TO+202.0 TO+210.7 TO+219.5 TO+79.0 TO+87.8 TO+96.6 TO+105.4 TO+114.1 TO+122.9 TO+140.5 TO+149.3 TO+158.0 TO+166.8 TO+175.6 TO+184.4 TO+131. 7 TO+O.O TO+8.8 TO+17.6 TO+26.3 TO+43.9 TO+35.1 TO+52.7 TO+61. 5 TO+70.2 05/02/02 13:29:14 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 003 003 013 013 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 005 005 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 014 009 009 LTE LTE UTE UTE UTE UTE 009 009 UTE UTE 008 008 010 010 UTE UTE UTE UTE CL CL WAR WAR 2031 2031 2031 2031 2031 2031 2031 2032 2031 2045 4094 4094 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2045 2046 2045 2046 4094 2045 2045 2046 2045 2045 2045 2045 2046 2045 4088 4088 4088 2045 4088 4088 4088 2045 2045 2046 2045 4088 4088 4088 4088 4088 4088 2045 2045 4088 2075 4094 4094 2105 2032 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET Page 34 of 155 PROBE 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 46081 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460S1 460SI 460HR 460SI 460SI 46081 460HR 460HR 460HR 460HR 46081 46081 46081 46081 46081 46081 460HR 460HR 46081 460HR 46081 46081 460HR 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 2

3 7

8 9

10 12 13 14 15 16 17 18 21 25 29 30 42 43 44 45 48 50 53 55 57 60 64 67 68 69 70 71 74 76 78 79 80 81 83 84 85 86 87 93 94 6.09 15.46 6.12 7.00 3.92 3.20 10.18 5.39 3.65 0.86 0.54 4.37

1. 55 2.39 0.48 5.20 3.22 0.25 3.10 2.46
1. 57
1. 71 0.36
1. 91 3.81
1. 48 3.57 1.81 2.19 4.68 2.56 1.19 3.16 0.57
1. 34 4.57 2.60
1. 20
1. 74 2.80 2.21
1. 84 3.70 3.15 4.27 2.69 2.78 1.20 2.03 3.12 4.22 2.43 2.75 0.21 4.72 0.20 0.28 0.47 0.52 0.70
1. 49
1. 31 0.30 0.46 0.61 0.64 0.40
1. 98
1. 45 1.31 4.35 0.14 0.15 5.32 2.15 170 1 ONT 179 1 ONT 180 1 ONT 178 1 ONT 178 1 ONT 13 2

TEA 181 1 ONT 180 1 ONT 22 2

TEA 136 P 3 TWO 20 134 P 3 TWO 13 162 1 ONT 18 2

TEA 20 2

TEA 78 P 3 TWO 12 26 2

TEA 19 2

TEA 148 2 VOL 27 2

TEA 19 2

TEA 12 2

TEA 22 2

TEA o

P 3 TWO 7 19 2

TEA 23 2

TEA 26 2

TEA 22 2

TEA 29 2

TEA 22 2

TEA 181 1 ONT 19 2

TEA 17 2

TEA 20 2

TEA 14 2

VOL 23 2

TEA 178 1 ONT 24 2

TEA 18 2

TEA 23 2

TEA 26 2

TEA 184 1 ONT 15 2

TEA 25 2

TEA 24 2

TEA 25 2

TEA 27 2

TEA 21 2

TEA 20 P 1 TEA 21 2

TEA 27 2

TEA 26 2

TEA 27 2

TEA 25 2

TEA 150 P 3 TWO 5 23 2

TEA 153 P 3 TWO 0 174 P 3 TWO 33 9

P 3 TWO 43 7

P 3 TWO 45 11 P 3 TWO 52 22 P 3 TWO 76 18 P 3 TWO 71 20 P 3 TWO 34 12 P 3 TWO 42 1

P 3 TWO 49 2

P 3 TWO 50 176 P 3 TWO 0 24 P 3 TWO 88 49 P 1 SCI 21 2

TEA 179 1 ONT 70 2

VOL 152 P 3 TWO 3 175 1 DNT 20 2

TEA 010 010 UTE UTE LTE UTE LTE UTS UTE 010 009 013 UTE UTE 009 UTE UTE 009 UTE UTE UTE UTE 008 UTE UTE UTE UTE UTE UTE 015 UTE UTE UTE UTE UTE 006 UTE UTE UTE UTE UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 007 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 009 LTE UTE

+0.61

-0.15

-11. 63

-12.47

+10.38

-0.20

+10.24

+11.11

-0.28

-0.59

-0.60

+9.75

-0.24

-0.20

-0.46

-0.17

-0.23

-0.60

-0.24

-0.31

-0.18

-0.19

+0.53

-0.31

-0.22

-0.26

-0.23

-0.21

-0.20

+2.20

-0.16

-0.20

-0.21

-0.86

-0.14

+3.04

-0.19

-0.17

-0.20

-0.11

+6.42

-0.19

-0.17

-0.16

-0.13

-0.19

-0.16

-0.28

-0.27

-0.13

-0.21

-0.22

-0.17

+0.67

-0.19

-0.44

-0.44

-0.44

-0.44

-0.44

-0.44

-0.44

-0.44

-0.44

-0.44

-0.44

-0.44

-0.44

-0.44

-0.16

-11.49

+1.16

-0.74

+11.52

-0.17 T0+127.3 TO+136.1 TO+144.9 T0+153.7 T0+162.4 TO+171.2 TO+188.8 T0+197.6 TO+206.3 TO+215.1 TO+223.9 TO+232.7 T0+180.0 05/02/02 13:29:15 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG 010 010 010 010 UTE UTE UTE UTE LTE LTE UTE UTE LTE LTE UTS UTS UTE UTE 010 010 009 009 013 013 UTE UTE UTE UTE 009 009 UTE UTE UTE UTE 009 009 UTE UTE UTE UTE UTE UTE UTE UTE 008 008 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 015 015 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 006 006 UTE UTE UTE UTE UTE UTE UTE UTE UTS UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 007 007 UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE UTE UTE 014 014 009 009 LTE LTE UTE UTE WAR WAR WAR WAR CS WAR CL WAR 4050 4106 4106 4106 4050 2031 4050 4050 2032 4050 4050 4050 2032 2032 4050 2031 2032 4050 2031 2032 2031 2032 4041 2032 2032 2032 2031 2031 2031 4106 2031 2032 2032 2031 2045 4094 2046 2045 2046 2045 4094 2046 2045 2046 2045 2045 2045 2046 2045 2046 2046 2045 2046 4088 2045 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2046 2045 4088 4088 4088 4088 2046 OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET INLET OUTLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 35 of 155 PROBE 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460HR 460HR 460SI 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460SI 460S1 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS - MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 35 99 35 100 35 102 35 103 35 104 35 105 35 106 35 108 36 1

36 2

36 7

36 8

36 9

36 10 36 12 36 13 36 15 36 16 36 19 36 23 36 26 36 28 36 29 36 31 36 36 36 37 36 39 36 40 36 41 36 44 36 48 36 50 36 52 36 53 36 54 36 56 36 61 36 62 36 64 36 65 36 69 36 70 36 71 36 73 36 75 36 76 36 77 36 78 36 79 36 81 36 86 36 87 36 89 36 90 36 91 36 94 36 95 36 96 4.48 3.31 4.96 0.32 4.38 2.44 7.42 6.33 2.38 2.31

1. 62 0.24
1. 81 0.06 4.78 0.57 3.50 3.24 0.50 4.18 0.66 3.34 0.44 3.48 2.98 2.32 0.31 1.11 2.63 2.70
1. 94 2.15 3.99 3.32 3.26 2.30 3.39
1. 96 2.32 6.12 4.30 0.99 1.28 2.21 2.66 2.28 3.77 6.08 4.11 2.88 3.49 2.70
1. 53 5.37 2.60 7.49 3.52 3.18
1. 51 5.55 4.14
1. 61 4.30
1. 94
1. 91 0.49 0.56 3.77 5.86 8.12 2.79 3.99 6.46 4.11 8.67 29 2

TEA UTE 31 2

TEA UTE 173 1 DNT UTE 22 2

VOL 014 169 1 DNT LTE 25 2

TEA UTE 175 1 DNT UTE 180 1 DNT LTE 16 2

TEA UTE 24 2

TEA UTE 21 2

TEA UTE 45 P 3 TWD 5 009 28 2

TEA UTE 58 2

VOL 013 21 2

TEA UTE 142 P 3 TWD 14 010 21 2

TEA UTE 24 2

TEA UTE 91 P 3 TWD 12 010 23 2

TEA UTE 88 P 3 TWD 16 010 15 2

TEA UTE 77 P 3 TWO 11 010 20 2

TEA UTE 18 2

TEA UTE 22 2

TEA UTE 101 P 3 TWD 7 009 19 2

TEA UTE 27 2

TEA UTE 27 2

TEA UTE 18 2

TEA UTE 17 2

TEA UTE 174 1 DNT LTE 23 2

TEA UTE 18 2

TEA UTE 23 2

TEA UTE 22 2

TEA UTE 17 2

TEA UTE 23 2

TEA UTE 24 2

TEA UTE 22 2

TEA UTE 26 2

TEA UTE 24 2

TEA UTE 18 2

TEA UTE 20 2

TEA UTE 23 2

TEA UTE 24 2

TEA UTE 22 2

TEA UTE 30 2

TEA UTE 19 2

TEA UTE 23 2

TEA UTE 25 2

TEA UTE 19 2

TEA UTE 20 2

TEA UTE 13 2

TEA UTE 22 2

TEA UTE 25 2

TEA UTE 31 2

TEA UTE 11 2

TEA UTE 25 2

TEA UTE 25 2

TEA UTE 47 2

TEA UTE 163 1 ONT 006 18 2

TEA UTE 27 2

TEA UTE 39 2

VOL 014 105 P 3 TWO 12 009 27 2

TEA UTE 171 1 DNT UTE 176 1 DNT LTE 20 2

TEA UTE 177 1 ONT UTE 174 1 DNT LTE 27 2

TEA UTE 180 1 DNT LTE

-0.19

-0.25

-11. 62

+0.86

+11.29

-0.19

-11.52

+11.24

-0.21

-0.25

-0.16

+0.10

-0.24

+1.11

-0.14

+0.66

-0.17

-0.16

-0.65

-0.18

-0.64

-0.20

+0.51

-0.21

-0.16

-0.21

-0.73

-0.21

-0.34

-0.21

-0.20

-0.26

+7.14

-0.31

-0.18

-0.17

-0.30

-0.20

-0.21

-0.26

-0.21

-0.24

-0.28

-0.25

-0.24

-0.24

-0.27

-0.24

-0.16

-0.20

-0.17

-0.21

-0.17

-0.21

-0.22

-0.21

-0.20

-0.18

-0.24

-0.16

-0.17

-0.20

+17.51

-0.21

-0.22

+0.88

+0.63

-0.22

-11.18

+10.95

-0.38

-11.29

+11. 30

-0.22

+11. 42 05/02/02 13:29:15 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE UTE UTE 014 014 LTE LTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE UTE UTE 009 009 WAR UTE UTE 013 013 UTE UTE 010 010 WAR UTE UTE UTE UTE 010 010 WAR UTE UTE 010 010 WAR UTE UTE 010 010 WAR UTE UTE UTE UTE UTE UTE 009 009 WAR UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 006 006 UTE UTE UTE UTE 014 014 009 009 WAR UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE LTE LTE UTE UTE LTE LTE 2045 2046 4088 4088 4088 2045 4088 4088 2046 2075 2104 4088 2075 4094 2105 4050 2024 2023 4050 2023 4050 2023 4050 2023 2023 2023 4050 2023 2032 2031 2031 2032 4041 2032 2031 2031 2032 2031 2031 2032 2031 2031 2032 2032 2032 2031 2032 2032 2045 2045 2045 2046 2046 2045 2046 2046 2046 2045 2046 2045 2046 2046 4088 2046 2046 4088 4088 2045 4083 4083 2045 4083 4083 2046 4083 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET OUTLET INLET INLET OUTLET INLET OUTLET INLET OUTLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 36 of 155 PROBE 460HR 460HR 460SI 460SI 460SI 460HR 460SI 460SI 460HR 460HR 460HR 460SI 460HR 460SI 460HR 460SI 460HR 460HR 460SI 460HR 460SI 460HR 460SI 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460HR 460SI

Framatome ANP Inc.

05/02/02 13:29:15 Cus tomer Name: Oconee unit 1 Component: S/G B Page 37 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

36 97 0.96 25 2

TEA UTE

-0.15 UTE UTE 2045 INLET 460HR 36 99 0.11 75 2

VOL 014

+0.97 014 014 4088 INLET 460SI 36 101 6.09 29 2

TEA UTE

-0.17 UTE UTE 2045 INLET 460HR 36 103 0.46 38 2

VOL 014

+1.19 014 014 4088 INLET 460SI 36 104 5.12 178 1 DNT UTE

-10.52 UTE UTE 4088 INLET 460SI 2.37 176 1 DNT LTE

+12.49 LTE LTE 4088 INLET 460SI 36 106 2.64 28 2

TEA UTE

-0.17 UTE UTE 2045 INLET 460HR 36 108 2.36 25 2

TEA UTE

-0.21 UTE UTE 2046 INLET 460HR 36 109 7.35 179 1 DNT 008

+0.55 008 008 4130 INLET 460SI 36 111 0.19 98 2

VOL 004

+1.33 004 004 4088 INLET 460SI 0.18 87 2

VOL 004

+1.56 004 004 4088 INLET 460SI 2.27 28 2

TEA UTE

-0.25 UTE UTE 2075 INLET 460HR 37 5

1. 63 153 1 DNT LTE

+10.11 LTE LTE 4048 OUTLET 460SI 10.63 177 1 DNT 010

+0.24 010 010 4048 OUTLET 460SI 8.12 186 1 DNT UTE

-11.28 UTE UTE 4048 OUTLET 460SI 3.12 25 2

TEA UTE

-0.14 UTE UTE 2024 INLET 460HR 37 6

3.76 171 1 DNT 004

+9.33 004 004 4048 OUTLET 460SI 2.12 14 2

TEA UTE

-0.12 UTE UTE 2023 INLET 460HR 37 8

2.89 25 2

TEA UTE

-0.17 UTE UTE 2024 INLET 460HR 37 9

3.69 22 2

TEA UTE

-0.17 UTE UTE 2023 INLET 460HR 37 11 0.35 40 P 3 TWD 7 010

+0.43 010 010 WAR 4048 OUTLET 460SI 4.65 24 2

TEA UTE

-0.19 UTE UTE 2023 INLET 460HR 37 12 0.61 60 P 3 TWD 12 010

-0.77 010 010 WAR 4048 OUTLET 460SI 3.74 23 2

TEA UTE

-0.18 UTE UTE 2024 INLET 460HR 37 13 2.24 20 2

TEA UTE

-0.20 UTE UTE 2023 INLET 460HR 37 14 0.68 85 P 3 TWD 13 009

-0.75 009 009 WAR 4048 OUTLET 460SI 2.30 23 2

TEA UTE

-0.15 UTE UTE 2024 INLET 460HR 37 15 2.47 175 1 DNT LTS

-2.43 LTS LTS 4048 OUTLET 460SI 1.84 24 2

TEA UTE

-0.17 UTE UTE 2023 INLET 460HR 37 16 4.00 24 2

TEA UTE

-0.19 UTE UTE 2024 INLET 460HR 37 17 0.71 34 2

TEA UTE

-0.18 UTE UTE 2023 INLET 460HR 37 23 3.70 22 2

TEA UTE

-0.17 UTE UTE 2024 INLET 460HR 3'7 27 2.45 19 2

TEA UTE

-0.15 UTE UTE 2024 INLET 460HR 37 28 2.48 14 2

TEA UTE

-0.20 UTE UTE 2023 INLET 460HR 37 29 3.33 20 2

TEA UTE

-0.16 UTE UTE 2024 INLET 460HR 37 32

1. 75 17 2

TEA UTE

-0.16 UTE UTE 2023 INLET 460HR 37 33 2.49 20 2

TEA UTE

-0.14 UTE UTE 2024 INLET 460HR 37 34 2.08 25 2

TEA UTE

-0.17 UTE UTE 2023 INLET 460HR 37 37 2.49 24 2

TEA UTE

-0.11 UTE UTE 2024 INLET 460HR 37 38 0.51 7

P 3 TWD 0 UTE

-0.42 TO+44.4 UTE UTS 2023 INLET 460HR 0.43 143 P 3 TWD 60 UTE

-0.42 TO+53.3 UTE UTS 2023 INLET 460HR 0.81 57 P 3 TWD 82 UTE

-0.42 To+62.2 UTE UTS 2023 INLET 460HR 0.53 69 P 3 TWD 66 UTE

-0.42 TO+71.1 UTE UTS 2023 INLET 460HR 0.32 162 P 3 TWD 0 UTE

-0.42 TO+80.0 UTE UTS 2023 INLET 460HR

1. 62 32 P 1 SCI UTE

-0.42 UTE UTS CL!CS 2023 INLET 460HR 37 39 2.34 20 2

TEA UTE

-0.11 UTE UTE 2024 INLET 460HR 37 40 2.28 20 2

TEA UTE

-0.20 UTE UTE 2023 INLET 460HR 37 45 4.56 20 2

TEA UTE

-0.20 UTE UTE 2031 INLET 460HR 37 46 1.14 23 2

TEA UTE

-0.31 UTE UTE 2032 INLET 460HR 37 47 2.32 27 2

TEA UTE

-0.20 UTE UTE 2031 INLET 460HR 37 48 3.90 21 2

TEA UTE

-0.25 UTE UTE 2032 INLET 460HR 37 50 4.15 23 2

TEA UTE

-0.18 UTE UTE 2032 INLET 460HR 37 59 3.66 17 2

TEA UTE

-0.22 UTE UTE 2046 INLET 460HR 37 60 3.65 22 2

TEA UTE

-0.11 UTE UTE 2045 INLET 460HR 37 62 7.76 26 2

TEA UTE

-0.16 UTE UTE 2045 INLET 460HR 37 64 2.97 25 2

TEA UTE

-0.13 UTE UTE 2045 INLET 460HR 37 71 2.36 15 2

TEA UTE

-0.15 UTE UTE 2046 INLET 460HR 7.17 167 1 DNT 009

+17.37 009 009 4083 INLET 460SI 12.21 169 1 DNT 009

+18.31 009 009 4083 INLET 460SI 37 76 2.85 20 2

TEA UTE

-0.16 UTE UTE 2045 INLET 460HR 37 77 1.25 26 2

TEA UTE

-0.23 UTE UTE 2046 INLET 460HR 37 78 2.10 23 2

TEA UTE

-0.14 UTE UTE 2045 INLET 460HR 37 79 4.21 18 2

TEA UTE

-0.14 UTE UTE 2046 INLET 460HR 37 80 2.41 35 2

TEA UTE

-0.14 UTE UTE 2045 INLET 460HR 37 86 2.37 19 2

TEA UTE

-0.09.

UTE UTE 2045 INLET 460HR 37 87 2.48 18 2

TEA UTE

-0.21 UTE UTE 2046 INLET 460HR 37 88 3.01 29 2

TEA UTE

-0.16 UTE UTE 2045 INLET 460HR 37 92 1.14 30 2

TEA UTE

-0.22 UTE UTE 2046 INLET 460HR 37 93

1. 81 31 2

TEA UTE

-0.25 UTE UTE 2045 INLET 460HR 37 94 2.09 21 2

TEA UTE

-0.22 UTE UTE 2046 INLET 460HR 37 96 2.30 27 2

TEA UTE

-0.18 UTE UTE 2046 INLET 460HR 37 97 3.39 24 2

TEA UTE

-0.16 UTE UTE 2045 INLET 460HR 37 98

1. 42 20 2

TEA UTE

-0.10 UTE UTE 2046 INLET 460HR 37 99 0.26 98 2

VOL 014

+0.82 014 014 4083 INLET 460SI 0.37 162 P 3 TWD 8 009

-0.79 009 009 WAR 4083 INLET 460SI

Framatome ANP Inc.

05/02/02 13:29:16 Customer Name: Oconee Unit 1 Component: S/G B Page 38 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS.,. MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

37 108 2.93 22 2

TEA UTE

-0.22 UTE UTE 2046 INLET 460HR 38 2

2.93 23 2

TEA UTE

-0.15 UTE UTE 2024 INLET 460HR 38 5

4.91 172 1 DNT LTE

+10.05 LTE LTE 4048 OUTLET 460SI 10.40 170 1 DNT 010

+0.06 010 010 4048 OUTLET 460SI 4.35 160 1 DNT UTE

-11. 33 UTE UTE 4048 OUTLET 460SI 5.28 24 2

TEA UTE

-0.14 UTE UTE 2024 INLET 460HR 38 6

0.69 83 P 3 TWD 13 008

+0.59 008 008 WAR 4048 OUTLET 460SI 7.73 173 1 DNT 010

+0.51 010 010 4048 OUTLET 460SI 12.73 182 1 DNT 010

-0.60 010 010 4048 OUTLET 460SI 3.26 29 2

TEA UTE

-0.19 UTE UTE 2023 INLET 460HR 38 8

4.17 29 2

TEA UTE

-0.11 UTE UTE 2024 INLET 460HR 38 9

2.40 11 2

TEA UTE

-0.15 UTE UTE 2023 INLET 460HR 38 10 1.04 90 P 3 TWD 19 010

-0.63 010 010 WAR 4048 OUTLET 460SI 3.72 24 2

TEA UTE

-0.15 UTE UTE 2024 INLET 460HR 38 13 0.72 86 P 3 TWD 14 010

-0.78 010 010 WAR 4048 OUTLET 460SI 2.40 29 2

TEA UTE

-0.16 UTE UTE 2024 INLET 460HR 38 14 2.82 24 2

TEA UTE

-0.17 UTE UTE 2023 INLET 460HR 38 15 2.74 20 2

TEA UTE

-0.11 UTE UTE 2024 INLET 460HR 38 24 1.01 16 2

TEA UTE

-0.19 UTE UTE 2023 INLET 460HR 0.57 14 2

VOL 013

+3.22 013 013 4041 OUTLET 460SI 38 25 2.06 15 2

TEA UTE

-0.11 UTE UTE 2024 INLET 460HR 38 29 4.28 179 1 DNT UTS

+8.94 UTS UTS 4041 OUTLET 460SI 2.61 173 1 ONT UTS

+9.90 UTS UTS 4041 OUTLET 460SI 38 30 2.53 17 2

TEA UTE

-0.15 UTE UTE 2023 INLET 460HR 38 31 2.74 20 2

TEA UTE

-0.09 UTE UTE 2024 INLET 460HR 38 32 3.22 20 2

TEA UTE

-0.20 UTE UTE 2023 INLET 460HR 38 38 2.20 20 2

TEA UTE

-0.14 UTE UTE 2023 INLET 460HR 38 39 0.16 0

P 3 TWD 3 007

+0.01 007 007 WAR 4041 OUTLET 460SI 38 40 2.71 33 2

TEA UTE

-0.16 UTE UTE 2023 INLET 460HR 38 42 2.16 20 2

TEA UTE

-0.17 UTE UTE 2023 INLET 460HR 38 43

1. 28 22 2

TEA UTE

-0.16 UTE UTE 2031 INLET 460HR 38 47 4.54 182 1 ONT UTS

-20.83 UTS UTS 4041 OUTLET 460SI 0.96 75 1

VOL UTS

-21. 15 UTS UTS 4041 OUTLET 460SI 38 49

1. 44 23 2

TEA UTE

-0.13 UTE UTE 2031 INLET 460HR 38 50 3.97 33 P 1 SCI UTE

-0.55 UTE UTS CL/CS 2032 INLET 460HR 0.65 349 P 3 TWD 0 UTE

-0.55 TO+259.0 UTE UTS 2032 INLET 460HR 0.80 7

P 3 TWO 42 UTE

-0.55 TO+267.8 UTE UTS 2032 INLET 460HR 2.47 36 P 3 TWO 73 UTE

-0.55 TO+276.6 UTE UTS 2032 INLET 460HR

1. 86 46 P 3 TWD 64 UTE

-0.55 TO+294.1 UTE UTS 2032 INLET 460HR 0.63 350 P 3 TWD 0 UTE

-0.55 TO+302.9 UTE UTS 2032 INLET 460HR 3.74 37 P 3 TWO 90 UTE

-0.55 TO+285.4 UTE UTS 2032 INLET 460HR 38 58 0.58 154 P 3 TWD 11 007

-0.31 007 007 WAR 4094 OUTLET 460SI 38 59 3.16 26 2

TEA UTE

-0.13 UTE UTE 2045 INLET 460HR 38 61 3.53 22 2

TEA UTE

-0.17 UTE UTE 2046 INLET 460HR 38 63 3.52 21 2

TEA UTE

-0.20 UTE UTE 2045 INLET 460HR 38 64 4.26 25 2

TEA UTE

-0.19 UTE UTE 2045 INLET 460HR 38 66 3.36 18 2

TEA UTE

-0.16 UTE UTE 2045 INLET 460HR 38 67 3.80 27 2

TEA UTE

-0.22 UTE UTE 2046 INLET 460HR 38 69 1.79 13 2

TEA UTE

-0.21 UTE UTE 2046 INLET 460HR 38 70 7.25 26 2

TEA UTE

-0.19 UTE UTE 2045 INLET 460HR 38 71

1. 76 16 2

TEA UTE

-0.21 UTE UTE 2046 INLET 460HR 38 75 2.87 19 2

TEA UTE

-0.23 UTE UTE 2046 INLET 460HR 10.02 176 1 DNT 001

-18.42 001 001 4083 INLET 460SI 38 77 3.06 22 2

TEA UTE

-0.15 UTE UTE 2046 INLET 460HR 38 80

1. 67 21 2

TEA UTE

-0.09 UTE UTE 2045 INLET 460HR 38 81 3.94 25 2

TEA UTE

-0.22 UTE UTE 2046 INLET 460HR 38 83 2.00 18 2

TEA UTE

-0.20 UTE UTE 2046 INLET 460HR 38 91 2.52 22 2

TEA UTE

-0.12 UTE UTE 2045 INLET 460HR 38 96

1. 59 20 2

TEA UTE

-0.33 UTE UTE 2045 INLET 460HR 38 98 2.61 23 2

TEA UTE

-0.16 UTE UTE 2045 INLET 460HR 38 99 2.59 21 2

TEA UTE

-0.26 UTE UTE 2046 INLET 460HR 38 102 2.52 22 2

TEA UTE

-0.15 UTE UTE 2045 INLET 460HR 38 107 3.81 25 2

TEA UTE

-0.17 UTE UTE 2045 INLET 460HR 38 108

1. 67 16 2

TEA UTE

-0.23 UTE UTE 2046 INLET 460HR 38 109 2.60 24 2

TEA UTE

-0.15 UTE UTE 2045 INLET 460HR 39 1

1. 06 93 P 3 TWO 19 010

-0.41 010 010 WAR 4048 OUTLET 460SI 39 3

3.30 167 1 DNT UTE

-5.18 UTE UTE 4048 OUTLET 460SI 3.85 21 2

TEA UTE

-0.16 UTE UTE 2023 INLET 460HR 39 5

11.53 169 1 DNT 010

+0.10 010 010 4048 OUTLET 46051 39 6

0.76 87 P 3 TWO 14 009

-0.76 009 009 WAR 4048 OUTLET 46051 10.12 178 1 DNT 010

-0.28 010 010 4048 OUTLET 460SI 12.11 180 1 DNT 010

+0.45 010 010 4048 OUTLET 46051 2.12 21 2

TEA UTE

-0.20 UTE UTE 2023 INLET 460HR 39 7

0.21 136 2 VOL 010

+3.49 010 010 4048 OUTLET 460SI 3.76 27 2

TEA UTE

-0.15 UTE UTE 2024 INLET 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 8

10 11 12 13 14 15 16 18 19 20 23 24 27 34 35 37 39 42 45 47 49 51 54 57 58 59 61 63 64 65 67 68 70 75 77 78 79 82 84 86 88 89 90 91 92 93 94 95 96 104 4.09 0.54 3.18 0.62 0.33 2.49 3.51 0.59 1.21 0.41 0.94 0.52 0.63 1.08

1. 68 1.04 0.65 0.59 0.51 2.30 2.66 2.35 3.32 0.63
1. 34 0.48 4.31 2.00 0.80 0.80
1. 99 2.62 2.30 0.87 0.85 4.78 4.93 7.64 5.42 1.56 1.19 1.19 0.34 2.90 3.47 3.16 4.42
1. 55 2.06 2.63 4.28 3.44 3.50 3.77 2.48 3.61 1.20 4.70 2.39 4.64 3.13
1. 56
1. 79
1. 79 2.31 2.43 0.08
1. 84 2.88 3.90 3.72 0.15 0.11
1. 61 2.26 2

TEA 19 53 22 79 125 16 19 120 22 97 46 170 16 24 27 29 25 22 196 173 167 166 27 o

11 P 3 TWD 10 2

TEA P 3 TWD 12 P 3 TWD 7 2

TEA 2

TEA P 3 TWD 11 2

TEA P 3 TWD 8 P 1 SCI P 3 TWD 0 P 3 TWD 50 P 3 TWD 66 P 3 TWD 83 P 3 TWO 65 P 3 TWD 51 P 3 TWD 49 P 3 TWD 0 1

ONT 1

ONT 1

DNT 2

TEA P 3 TWD 11 2

TEA o

P 167 1 9

2 20 2

20 2

21 2

175 1 18 2

22 2

24 2

26 2

6 1

180 24 19 24 24 i

2 2

2 2

26 P

174 1 18 2

22 2

25 2

21 2

28 2

18 2

183 1 29 2

171 1 21 2

32 2

24 2

25 2

30 2

21 2

23 2

21 2

23 2

20 2

21 2

27 2

24 2

103 2 17 2

25 2

27 2

29 2

70 2

101 2 17 2

32 2

3 TWO 8 DNT TEA SAl TWO 59 TEA DNT TEA TWO 74 MAl TEA ONT ONT TEA TEA SAl TWD 73 3 TWD 6 DNT TEA TEA TEA TEA TEA TEA DNT TEA DNT TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA VOL TEA TEA TEA TEA VOL VOL TEA TEA UTE 010 UTE 010 010 UTE UTE 010 UTE 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE LTS LTS LTS UTE 008 UTE 008 LTS UTE UTE UTE UTE 003 UTE UTE UTE UTE 003 LTS UTE UTE UTE UTE 007 UTS UTE UTE UTE UTE UTE UTE 003 UTE 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 UTE UTE UTE UTE 014 003 UTE UTE

-0.21

+0.65

-0.14

-0.81

+0.62

-0.21

-0.14

-0.69

-0.21

-0.69

-0.30

-0.30

-0.30

-0.30

-0.30

-0.30

-0.30

-0.30

.,.0.30

+10.66

+11. 70

+12.65

-0.15

-0.62

-0.20

+0.67

-9.64

-0.20

-3.61

-3.61

-0.23

-16.95

-0.16

-3.11

-3.11

-0.16

-6.79

-2.65

-0.44

-0.25

-3.34

-3.34

+0.56

+3.56

-0.14

-0.25

-0.21

-0.17

-0.19

-0.22

+15.37

-0.20

+9.44

-0.25

-0.19

-0.19

-0.20

-0.16

-0.22

-0.17

-0.23

-0.14

-0.23

-0.22

-0.17

-0.26

+1.38

-0.28

-0.18

-0.24

-0.23

+1.14

+5.24

-0.28

-0.12 TO+244.4 TO+253.3 TO+262.2 TO+271.1 TO+280.0 TO+288.9 TO+297.8 TO+306.7 05/02/02 13:29:16 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE 010 010 UTE UTE 010 010 010 010 UTE UTE UTE UTE 010 010 UTE UTE 010 010 UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS LTS LTS LTS LTS LTS LTS UTE UTE 008 008 UTE UTE 008 008 LTS LTS UTE UTE UTE UTS UTE UTS UTE UTE 003 003 UTE UTE UTE UTS UTE UTS UTE UTE 003 003 LTS LTS UTE UTE UTE UTE UTE UTS UTE UTS 007 007 UTS UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 003 003 UTE UTE 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 014 UTE UTE UTE UTE UTE UTE UTE UTE 014 014 003 003 UTE UTE UTE UTE WAR WAR WAR WAR WAR CL WAR WAR TR TR WAR 2023 4048 2024 4048 4048 2023 2024 4048 2023 4048 2023 2023 2023 2023 2023 2023 2023 2023 2023 4048 4048 4048 2024 4041 2023 4041 4041 2023 2078 2078 2023 4041 2023 2023 2023 2023 4041 4041 2032 2032 2031 2031 4041 4041 2031 2032 2045 2045 2045 2046 4094 2045 4094 2045 2046 2046 2045 2045 2046 2045 2046 2046 2046 2046 2045 2046 4083 2046 2045 2046 2045 4083 4083 2046 2045 INLET OUTLET INLET OUTLET OUTLET INLET INLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET OUTLET INLET OUTLET OUTLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 39 of 155 PROBE 460HR 460SI 460HR 460SI 460SI 460HR 460HR 460SI 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460SI 460HR 460SI 460HR 460SI 460SI 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460SI 460SI 460HR 460HR 460HR 460HR 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460SI 460SI 460HR 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION 39 39 39 39 39 39 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 105 106 108 109 111 116 1

2 4

7 10 11 12 13 14 15 22 24 25 28 29 37 38 40 43 49 54 55 57 60 62 65 66 68 72 73 78 81 2.36

1. 39
1. 76 7.38 9.37 5.34 5.54
1. 05 1.05 4.54 0.15 0.28 0.20 4.25 10.19 13.42 0.47 2.95 3.35 2.19 0.33 0.25 0.42 0.51 1.55 0.11 0.70 4.00 2.62 0.47 0.40 0.54 0.93 1.24
1. 59 0.93
1. 37 1.06 2.42 2.24 0.60 0.44 2.73 2.47 6.18
1. 65 3.23 3.87
1. 45
1. 45 5.59 6.00 2.39 3.26 3.35 1.27 1.27 1.18 1.18 2.45 0.43 0.66 2.01 3.29 4.33 4.35 2.82 1.80 1.07 2.60 1.29 3.75 7.92 0.89 3.78 26 22 27 178 179 175 177 o

110 13 85 2

TEA 2

TEA 2

TEA 1

ONT 1

ONT 1

ONT 1

ONT P 3 TWO 9 P 3 TWO 22 2

TEA 2

VOL 3 TWO 5 VOL TEA ONT ONT o

P 69 2

24 2

180 1 179 1 47 P 3 TWO 9 11 25 29 o

14 14 13 o

91 o

24 30 51 56 359 10 19 27 34 26 34 22 17 20 18 23 26 22 24 28 194 29 29 27 189 23 22 19 24 24 26 26 34 90 34 18 21 20 20 14 18 33 21 14 22 26 24 23 1

2 2

ONT TEA TEA P 3 TWO 6 P 3 TWO 4 2

TWO 33 2

SAl P 3 TWO 24 2

VOL P 3 TWO 12 2

TEA P 1 SCI P 3 TWO 0 P 3 TWO 50 P 3 TWO 58 P 3 TWO 76 P 3 TWO 88 P 3 TWO 100 P 3 TWO 76 P 3 TWO 92 P 3 TWO 0 2

TEA 2

TEA 2

TWO 65 2

SAl 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 1

ONT 2

SAl 2

TWO 92 2

TEA 1

ONT 2

TEA 2

TEA 2

TEA 2

MAl 2

TWO 70 2

TWO 79 2

SAl P 1 SCI P 3 TWO 0 P 3 TWO 27 P 3 TWO 46 P 3 TWO 60 P 3 TWO 68 P 3 TWO 68 P 3 TWO 55 P 3 TWO 44 P 3 TWO 0 2

TEA 2

TEA 2

TEA 2

TEA 2

VOL 2

TEA UTE UTE UTE UTE UTE UTE LTS 010 010 UTE 001 011 013 UTE 010 010 010 UTS UTE UTE 008 010 UTE UTE 010 011 011 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTE UTE UTE 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE

-0.21

-0.21

-0.19

-11.76

-12.21

-12.59

-11.78

+0.57

+0.64

-0.20

+1.16

-0.32

+1.10

-0.21

+0.20

-0.28

-0.74

+4.21

-0.14

-0.16

-0.66

+0.51

-3.32

-3.32

-0.60

+0.97

+0.63

-0.19

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.22

-0.21

-0.18

-1. 27

-1. 27

-0.21

-0.20

-0.20

-0.11

-0.12

-14.81

-3.83

-3.83

-0.26

+15.98

-0.24

-0.21

-0.16

-2.64

-2.64

-3.56

-3.56

-0.06

-0.06

-0.06

-0.06

, -0.06

-0.06

-0.06

-0.06

-0.06

-0.06

-0.16

-0.19

-0.13

-0.12

-1. 44

-0.18 TO+294.1 TO+285.4 TO+276.6 TO+267.8 TO+259.0 TO+250.2 TO+241. 5 TO+232.7 TO+223.9 TO+96.6 TO+105.4 TO+114.1 TO+122.9 TO+131. 7 TO+140.5 TO+149.3 TO+158.0 TO+166.8 05/02/02 13:29:16 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTS LTS 010 010 010 010 UTE UTE 001 001 011 011 013 013 UTE UTE 010 010 010 010 010 010 UTS UTS UTE UTE UTE UTE 008 008 010 010 UTE UTS UTE UTS 010 010 011 011 011 011 UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTS UTE UTS UTE UTS UTE UTE 010 010 UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE WAR WAR WAR WAR WAR WAR WAR WAR CL CS TR TR CL TR 2046 2045 2045 4083 4083 4083 4083 4083 4100 2079 4041 4041 4041 2023 4041 4041 4041 4041 2024 2023 4041 4041 2023 2023 4041 4041 4041 2024 2024 2024 2024 2024 2024 2024 2024 2024 202~

2024 2024 2023 2023 2023 2024 2023 2023 2024 2024 4041 2031 2031 2032 4041 2031 2031 2045 2045 2045 2045 2045 2045 2045 2045 2045 2045 2045 2045 2045 2045 2045 2046 2045 2045 2045 2045 2046 INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 40 of 155 PROBE 460HR 460HR 460HR 460SI 460S1 460SI 460SI 460SI 460SI 460HR 460S1 460S1 460S1 460HR 460S1 460S1 460S1 460S1 460HR 460HR 460S1 460S1 460HR 460HR 460S1 460S1 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460HR 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS 7

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION 40 40 40 40 40 40 40 40 40 40 40 40 40 41 41 41 41 41 41 41 41 41 41 41 41 85 86 87 90 94 97 99 100 102 103 106 109 117 1

2 3

4 6

7 8

9 11 13 14 15 2.41 10.41 1.72 1.72 2.03 3.65 3.34 4.41 3.44 2.37 2.82 1.13 1.13 7.77 10.16 10.28 0.45 9.13 3.58 4.57 3.99 8.73 0.87 0.36 0.29 0.23 0.28 0.40 0.50 0.61 0.66 0.66 0.61 0.62 0.62 0.58 0.53 0.46 0.40 0.35

1. 08 0.00 0.17 0.60 0.89 0.56 0.20 0.00 0.28 0.26 3.44 9.76 5.18 16.19 3.41 18.10 10.43 0.50 2.82 0.70 0.47 0.33 0.33 0.44
1. 78 0.19 0.93 2.94 0.79 0.71 0.71 0.46 0.35 2.89 2.98 TEA TEA SAl TWO 95 TEA TEA TEA TEA TEA TEA TEA MAl TWO 87 ONT ONT ONT 21 2

24 2

37 2

37 2

19 2

23 2

23 2

24 2

25 2

21 2

22 2

28 2

28 2

171 1 174 1 174 1 55 P

172 1 168 1 172 1 166 1 12 1

23 3 TWO 9 ONT ONT ONT ONT SAl P 1 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 1 P 3 P 3 P 3 P 3 P 3 P 3 P 3 2

10 2

SCI 41 30 17 28 28 26 25 25 30 34 32 28 27 29 33 38 43 21 o

28 16 11 13 2

o 40 248 22 168 28 178 26 174 173 68 21 59 142 17 17 156 30 83 129 29 125 24 24 36 119 169 170 1

2 1

2 1

1 TWO 0 19 17 19 23 25 28 29 29 28 28 28 27 26 24 23 o

TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO SCI TWO 0 TWO 9 TWO 23 TWO 32 TWO TWO TWO VOL PLP TEA ONT TEA ONT TEA ONT ONT 22 10 o

P 3 TWO 9 2

TEA P 3 TWO 13 P 3 TWO 9 2

SAl 2

TWO 45 P 3 TWO 6 2

TEA 2

VOL P 3 TWO 12 2

TEA P 3 TWO 14 2

SAl 2

TWO 76 P 3 TWO 8 P 3 TWO 7 1

ONT 1

ONT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 LTS LTS LTS LTS UTE LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS UTE UTE UTE UTE UTE UTE UTE UTE 013 013 UTE 010 UTE 010 UTE 010 010 009 UTE 010 009 UTE UTE 010 UTE 012 010 UTE 010 UTE UTE 010 010 LTS LTS

-0.22

-0.16

-3.58

-3.58

-0.22

-0.13

-0.19

-0.24

-0.19

-0.21

-0.27

-3.56

-3.56

-8.53

-11. 53

-11. 84

+0.42

-16.42

-16.14

-13.68

-11. 77

-2.21

+0.04

+0.04

+0.04

+0.04

+0.04

+0.04

+0.04

+0.04

+0.04

+0.04

+0.04

+0.04

+0.04

+0.04

+0.04

+0.04

+0.04

+0.04

-0.25

-0.25

-0.25

-0.25

-0.25

-0.25

-0.25

-0.25

+1.48

+1.32

-0.17

-0.00

-0.11

+0.06

-0.14

+0.28

-0.35

-0.48

-0.13

-0.69

-0.58

-3.57

-3.57

-0.67

-0.20

+1.10

-0.71

-0.17

-0.15

-3.62

-3.62

-0.58

-0.67

-6.75

-5.60 TO+134.3 TO+139.7 T0+145.1 TO+150.4 TO+155.8 TO+161. 2 TO+166.6 T0+171.9 TO+177.3 T0+182.7 T0+188.1 TO+193.4 T0+198.8 TO+204.2 TO+209.6 TO+214.9 TO+220.3 TO+17.8 TO+26.7 TO+35.6 TO+44.4 TO+53.3 TO+62.2 TO+71. 1 05/02/02 13:29:17 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE UTE UTS UTE UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UTE UTE UTE UTE UTE 009 009 LTS LTS LTS LTS LTS LTS LTS LTS UTE UTE LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 013 013 013 013 UTE UTE 010 010 UTE UTE 010 010 UTE UTE 010 010 010 010 009 009 UTE UTE 010 010 009 009 UTE UTS UTE UTS 010 010 UTE UTE 012 012 010 010 UTE UTE 010 010 UTE UTS UTE UTS 010 010 010 010 LTS LTS LTS LTS TR CL WAR WAR WAR WAR WAR WAR WAR WAR 2046 2045 2046 2046 2045 2045 2045 2046 2045 2045 2046 2045 2045 4083 4083 4083 4083 4083 4083 4083 4083 604 4071 4071 4071 4071 4071 4071 4071 4071 4071 4071 4071 4071 4071 4071 4071 4071 4071 4071 2099 2099 2099 2099 2099 2099 2099 2099 4071 4071 2098 4071 2099 4071 2098 4071 4071 4071 2099 4071 4071 2098 2098 4071 2099 4108 4071 2099 4071 2126 2126 4071 4067 4067 4067 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 41 of 155 PROBE 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 410MB 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460S1 460SI 460S1 460SI 460SI 460SI 460SI 460S1 460S1 460S1 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460HR 460SI 460HR 460SI 460HR 460SI 460SI 460SI 460HR 460SI 460S1 460HR 460HR 460SI 460HR 520SI 460SI 460HR 460SI 460HR 460HR 460S1 460SI 460SI 460SI

Framatome ANP Inc.

05/02/02 13:29:17 Customer Name: Oconee Unit 1 Component: S/G B Page 42 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS :- MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

4.07 25 2

TEA UTE

-0.15 UTE UTE 2099 INLET 460HR 41 19 2.44 21 2

TEA UTE

-0.17 UTE UTE 2099 INLET 460HR 41 27 3.21 35 2

TEA UTE

-0.17 UTE UTE 2099 INLET 460HR 41 29 2.54 27 2

TEA UTE

-0.17 UTE UTE 2099 INLET 460HR 41 33 3.64 26 2

TEA UTE

-0.19 UTE UTE 2099 INLET 460HR 41 38 3.92 31 2

TEA UTE

-0.14 UTE UTE 2098 INLET 460HR 41 43

1. 60 17 2

TEA UTE

-0.17 UTE UTE 2099 INLET 460HR 41 44 0.38 29 P 1 SCI UTE

-3.52 UTE UTS 2098 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-3.52 TO+213.3 UTE UTS 2098 INLET 460HR 0.12 l3 P 3 TWO 10 UTE

-3.52 TO+222.2 UTE UTS 2098 INLET 460HR 0.34 l3 P 3 TWD 29 UTE

-3.52 TO+231.1 UTE UTS 2098 INLET 460HR 0.40 15 P 3 TWD 34 UTE

-3.52 TO+240.0 UTE UTS 2098 INLET 460HR 0.38 13 P 3 TWD 32 UTE

-3.52 TO+248.9 UTE UTS 2098 INLET 460HR 0.26 12 P 3 TWD 22 UTE

-3.52 TO+257.8 UTE UTS 2098 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.52 TO+266.7 UTE UTS 2098 INLET 460HR 41 46

1. 63 19 2

TEA UTE

-0.22 UTE UTE 2098 INLET 460HR 0.31 45 2

SVI UTE

-1. 02 UTE UTE CS 2098 INLET 460HR 0.31 45 2

TWD 89 UTE

-1. 02 UTE UTE 2098 INLET 460HR 41 47 0.84 17 2

TEA UTE

-0.16 UTE UTE 2099 INLET 460HR 41 48 2.18' 27 2

TEA UTE

-0.24 UTE UTE 2098 INLET 460HR 41 49 4.52 164 1 DNT LTE

+2.39 LTE LTE 4067 INLET 460S1 1.13 25 2

SAl UTE

-3.63 UTE UTS 2099 INLET 460HR 1.13 25 2

TWO 69 UTE

-3.63 UTE UTS 2099 INLET 460HR 41 52 3.13 27 2

TEA UTE

-0.21 UTE UTE 2098 INLET 460HR 41 55 3.32 23 2

TEA UTE

-0.17 UTE UTE 2099 INLET 460HR 41 56 3.06 25 2

TEA UTE

-0.17 UTE UTE 2098 INLET 460HR 41 65

1. 08 20 2

TEA UTE

-0.16 UTE UTE 2049 INLET 460HR 41 67

1. 82 35 2

TEA UTE

-0.21 UTE UTE 2049 INLET 460HR 41 69 3.41 25 2

TEA UTE

-0.13 UTE UTE 2049 INLET 460HR 41 70 1.10 16 2

TEA UTE

-0.14 UTE UTE 2050 INLET 460HR 41 73 2.52 17 2

TEA UTE

-0.21 UTE UTE 2049 INLET 460HR 41 74 2.53 27 2

TEA UTE

-0.21 UTE UTE 2050 INLET 460HR 41 75 3.31 23 2

TEA UTE

-0.22 UTE UTE 2049 INLET 460HR 41 76 2.64 17 2

TEA UTE

-0.24 UTE UTE 2050 INLET 460HR 41 77 1.66 26 2

TEA UTE

-0.17 UTE UTE 2049 INLET 460HR 41 78

1. 90 24 2

TEA UTE

-0.25 UTE UTE 2050 INLET 460HR 41 81 4.45 27 2

TEA UTE

-0.18 UTE UTE 2049 INLET 460HR 41 89 3.46 24 2

TEA UTE

-0.13 UTE UTE 2049 INLET 460HR 41 94

1. 40 24 2

TEA UTE

-0.21 UTE UTE 2050 INLET 460HR 41 95 0.19 94 2

VOL 014

+0.67 014 014 4110 OUTLET 520S1 41 103 0.58 67 P 3 TWD 10 014

+0.64 014 014 4110 OUTLET 520S1 41 106 2.56 21 2

TEA UTE

-0.15 UTE UTE 2050 INLET 460HR 41 108 4.67 356 1 DNT LTE

+8.14 LTE LTE 4110 OUTLET 520S1 8.14 177 1 DNT UTE

-8.76 UTE UTE 4110 OUTLET 520S1 41 111 6.46 357 1 DNT UTE

-11. 86 UTE UTE 4110 OUTLET 520S1 2.12 175 1 ONT LTE

+10.55 LTE LTE 4130 INLET 460SI 5.62 171 1 ONT LTE

+9.70 LTE LTE 4130 INLET 460SI 41 112 0.14 129 2 VOL 009

-0.72 009 009 4102 OUTLET 460S1 41 114 11.68 176 1 DNT 009

-0.28 009 009 4102 OUTLET 460SI 41 116 0.33 0

P 3 TWO 5 010

+0.59 010 010 WAR 4102 OUTLET 460SI 42 1

3.22 22 2

TEA UTE

-0.13 UTE UTE 2099 INLET 460HR 42 2

0.86 27 2

SAl UTE

-3.48 UTE UTS 2098 INLET 460HR 0.86 27 2

TWO 78 UTE

-3.48 UTE UTS 2098 INLET 460HR 42 3

13.42 176 1 DNT 010

+0.53 010 010 4071 INLET 460SI 4.52 27 2

TEA UTE

-0.15 UTE UTE 2099 INLET 460HR 42 4

13.99 173 1 DNT 010

+0.35 010 010 4071 INLET 460S1 2.88 27 2

TEA UTE

-0.12 UTE UTE 2098 INLET 460HR 42 5

0.27 144 P 3 TWD 3 011

-0.69 011 011 WAR 4071 INLET 460SI 18.26 173 1 DNT 010

+0.53 010 010 4071 INLET 460S1 4.26 29 2

TEA UTE

-0.15 UTE UTE 2099 INLET 460HR 42 6

16.06 179 1 ONT 010

+0.09 010 010 4071 INLET 460SI 42 7

3.27 22 2

TEA UTE

-0.16 UTE UTE 2099 INLET 460HR 42 8

0.70 136 P 3 TWO 9 010

-0.65 010 010 WAR 4071 INLET 460SI 0.80 14 2

SAl UTE

-3.50 UTE UTS 2098 INLET 460HR 0.79 16 2

TWO 42 UTE

-3.50 UTE UTS 2098 INLET 460HR 42 10 0.54 121 P 3 TWO 10 010

+0.42 010 010 WAR 4071 INLET 460S1 42 11 0.35 77 P 3 TWO 7 010

-0.69 010 010 WAR 4071 INLET 460S1 0.41 136 P 3 TWD 5 010

+0.75 010 010 WAR 4071 INLET 460SI 0.85 27 2

SAl UTE

-3.66 UTE UTS 2126 INLET 460HR 0.85 27 2

TWO 88 UTE

-3.66 UTE UTS 2126 INLET 460HR 42 12 0.40 96 P 3 TWD 7 010

-0.85 010 010 WAR 4071 INLET 460S1 2.29 29 2

TEA UTE

-0.13 UTE UTE 2099 INLET 460HR 42 14 2.55 26 2

TEA UTE

-0.15 UTE UTE 2099 INLET 460HR 42 15 5.47 171 1 DNT 003

-6.24 003 003 4067 INLET 460S1 42 16 2.97 25 2

TEA UTE

-0.21 UTE UTE 2098 INLET 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 43 43 19 22 23 24 26 29 30 31 32 34 36 37 38 50 57 62 63 65 68 71 74 76 79 80 81 83 85 87 90 92 95 97 98 101 105 107 108 109 115 1

2 2.76 0.89 0.00 0.10 0.19 0.29 0.35 0.35 0.42 0.53 0.47 0.51 0.58 0.60 0.57 0.38 0.18 0.16 0.17 0.11 0.24 0.34 0.29 0.23 0.17 0.13 0.15 0.09 0.00 0.09 2.90 3.16 0.20 6.35 2.71 1.13 2.94 3.35 0.98 0.98 3.11 2.31 2.04 2.64 2.63 1.29 2.55

1. 58
1. 58 0.31
1. 31 8.70 0.52 8.78 4.79
1. 40 2.03 4.35 3.58 4.01 2.60 4.20 2.79 3.93
1. 79 0.22
1. 91 3.26 4.31 7.55 5.83 6.22
1. 71 4.31 3.08 26 20 o

147 30 35 31 30 25 20 20 19 19 19 22 26 24 43 27 54 35 32 28 30 40 50 34 33 o

71 25 19 80 31 22 16 17 28 17 17 22 27 24 33 21 359 21 19 19 85 18 27 72 23 30 17 20 30 18 26 21 29 26 25 15 2

P 1 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 1

2 2

2 TEA SCI TWD 0 TWD 9 TWD 17 26 31 32 38 48 42 46 52 54 51 35 16 14 16 10 22 30 26 21 15 12 13 8

TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL o

TEA TEA VOL TEA TEA TEA TEA TEA MAl TWD 45 TEA TEA TEA TEA TEA DNT TEA TWD 53 SAl P 3 TWD 6 2

TEA 2

TEA P 3 TWD 9 2

TEA 2

2 2

2 2

2 2

2 2

2 2

TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA 89 P

26 2

25 2

347 1 349 1 350 1 169 1 19 2

31 2

19 2

3 TWD 5 TEA TEA DNT DNT DNT DNT TEA TEA TEA UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 003 UTE UTE 001 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 007 UTE UTE 007 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 007 UTE UTE LTE LTE LTE UTE UTE UTE UTE

-0.26

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-3.61

-15.55

-0.15

-0.13

+1.49

-0.14

-0.19

-0.17

-0.27

-0.18

-1. 32

-1. 32

-0.23

-0.16

-0.12

-0.11

-0.19

-6.60

-0.20

-3.16

-3.16

-0.24

-0.26

-0.15

-0.27

-0.12

-0.29

-0.12

-0.13

-0.11

-0.20

-0.12

-0.12

-0.19

-0.18

-0.23

-0.19

+0.07

-0.15

-0.20

+10.93

+10.58

+7.88

-8.46

-0.12

-0.19

-0.17 TO+355.6 TO+4.4 TO+13.3 TO+22.2 TO+31.1 TO+40.0 TO+48.9 TO+57.8 TO+66.7 TO+75.6 TO+84.4 TO+93.3 TO+102.2 TO+111.1 TO+120.0 T0+128.9 TO+137.8 TO+146.7 TO+155.6 TO+164.4 TO+173.3 TO+182.2 T0+191.1 TO+200.0 TO+208.9 TO+217.8 TO+226.7 05/02/02 13:29:18 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS 003 003 UTE UTE UTE UTE 001 001 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS 007 007 UTE UTE UTE UTE 007 007 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 007 007 UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE TR WAR WAR WAR 2098 2098 2098 2098 2098 2098 2098 2098 2098 2098 2098 2098 2098 2098 2098 2098 2098 2098 2098 2098 2098 2098 2098 2098 2098 2098 2098 2098 2098 4067 2098 2098 4042 2099 2098 2099 2098 2098 2098 2098 2098 2099 2098 2098 2099 4110 2050 2050 2050 4110 2049 2050 4110 2055 2049 2049 2049 2049 2049 2049 2049 2050 2050 2049 2049 4110 2049 2049 4110 4110 4110 4110 2055 2099 2099 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET OUTLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET Page 43 of 155 PROBE 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 520S1 460HR 460HR 460HR 520SI 460HR 460HR 520SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 520SI 460HR 460HR 520SI 520SI 520SI 520SI 460HR 460HR 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION 43 43 43

-43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 3

4 5

6 7

8 9

11 12 13 14 15 16 17 18 19 22 23 24 25 27 28 34 36 37 46 47 48 49 52 53 55 57 58 60 63 65 67 69 70 74 75 76 77 78 79 80 81 83 85 86 88 3.76 14.33 1.68 17.35 14.68 2.71 15.67 3.79 7.29 1.16 1.16 0.61 0.61 2.00 0.44 0.62 1.02 0.85 0.85 0.47 0.43 6.57

1. 74 0.70 0.30 0.31 0.60 0.60 0.40 1.12 1.12 0.80 0.80
1. 61 0.90 0.90
1. 83 2.11 3.67 3.17 3.09 0.57 0.57 4.84
1. 64 0.37 0.22 0.15 3.41 4.48 0.21 4.41 2.53 2.95 2.40
1. 61 2.90 6.51 2.65 3.00 4.15 7.20 3.20 3.13 5.04 2.65 1.00 0.55 4.33 1.65 2.15 2.90 1.19 4.03 3.94 TEA DNT TEA DNT DNT TEA DNT TEA DNT SAl TWD 59 SVI TWD 44 DNT VOL 3 TWD 6 3 TWD 10 SAl TWD 72 SAl TWD 61 DNT TEA 21 2

169 1 24 2

168 1 172 1 23 2

169 1 25 2

169 1 22 2

22 2

72 2

72 2

173 1 19 2

o P

91 P

26 2

26 2

20 2

20 2

175 1 19 2

104 67 P 3 TWD 10 P 3 TWD 3 2

VOL 84 16 2

SAl 16 135 20 2

TWD 47 P 3 TWD 5 2

MAl 20 20 2

TWD 54 2

SAl 20 28 2

TWD 61 2

TEA 21 2

SAl 21 16 2

TWD 56 2

TEA 19 2

TEA 46 2

TEA 22 2

TEA 20 2

TEA 19 2

SAl 19 22 2

TWD 47 2

TEA 27 2

TEA 98 P

50 P

68 2

26 2

23 2

60 2

24 2

19 2

179 1 23 2

22 2

25 2

26 2

25 2

20 2

27 2

27 2

20 2

18 2

32 2

26 2

17 2

67 P

23 2

24 2

25 2

22 2

347 1 27 2

28 2

3 TWD 7 3 TWD 4 VOL TEA TEA VOL TEA TEA DNT TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA 3 TWD 10 TEA TEA TEA TEA DNT TEA TEA UTE 010 UTE 010 010 UTE 010 UTE 010 UTE UTE 014 014 UTE 014 010 010 UTE UTE UTE UTE 009 UTE 010 010 008 UTE UTE 008 UTE UTE UTE UTE UTE UTE UTE

. UTE UTE UTE UTE UTE UTE UTE UTE UTE 007 007 011 UTE UTE UTE UTE UTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 007 UTE UTE UTE UTE LTS UTE UTE MRPC/PLUS POINT

-0.19

-0.00

-0.18

+0.49

+0.01

-0.17

-0.15

-0.19

-0.58

-3.62

-3.62

+1. 39

+1. 39

-12.19

+1. 06

-0.57

-0.67

-3.71

-3.71

-3.66

-3.66

-0.01

-0.15

-0.74

-0.77

+0.60

-3.61

-3.61

-0.64

-3.60

-3.60

-3.54

-3.54

-0.36

-3.57

-3.57

-0.20

-0.22

-0.22

-0.21

-0.18

-1.23

-1. 23

-0.17

-0.21

+0.38

-0.02

+1.05

-0.20

-0.16

-3.75

-0.29

-0.27

+4.25

-0.19

-0.21

-0.20

-0.20

-0.22

-0.18

-0.20

-0.15

-0.25

-0.16

-0.09

-0.16

-0.12

-0.37

-0.20

-0.27

-0.10

-0.20

+0.48

-0.17

-0.18 05/02/02 13:29:18 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE 010 010 UTE UTE 010 010 010 010 UTE UTE 010 010 UTE UTE 010 010 UTE UTS UTE UTS 014 014 014 014 UTE UTE 014 014 010 010 010 010 UTE UTS UTE UTS UTE UTS UTE UTS 009 009 UTE UTE 010 010 010 010 008 008 UTE UTS UTE UTS 008 008 UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE UTE UTS UTE UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 007 007 007 007 011 011 UTE UTE UTE UTE UTE UTS UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 007 007 UTE UTE UTE UTE UTE UTE UTE UTE LTS LTS UTE UTE UTE UTE WAR WAR WAR WAR WAR TR WAR WAR WAR 2098 4042 2099 4042 4042 2099 4042 2098 4042 2099 2099 4042 4042 4042 4042 4042 4042 2099 2099 2126 2126 4042 2098 4042 4042 4042 2126 2126 4042 2098 2098 2126 2126 2098 2099 2099 2098 2094 2095 2095 2095 2095 2095 2094 2095 4067 4067 4067 2094 2095 2094 2094 2094 4067 2095 2049 2050 2050 2049 2049 2050 2050 2049 2050 2049 2050 2049 4110 2050 2049 2049 2049 4110 2050 2050 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET OUTLET INLET INLET Page 44 of 155 PROBE 460HR 460S1 460HR 460SI 460SI 460HR 460S1 460HR 460S1 460HR 460HR 460S1 460S1 460SI 460SI 460SI 460S1 460HR 460HR 460HR 460HR 460S1 460HR 460S1 460S1 460S1 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 520S1 460HR 460HR 460HR 460HR 520SI 460HR 460HR

Framatome ANP Inc.

05/02/02 13:29:19 Customer Name: Oconee Unit 1 Component: S/G B Page 45 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

43 89 3.02 25 2

TEA UTE

-0.12 UTE UTE 2049 INLET 460HR 43 93 3.68 25 2

TEA UTE

-0.14 UTE UTE 2049 INLET 460HR 43 94 4.62 355 1 DNT 013

-0.94 013 013 4110 OUTLET 520SI 2.27 23 2

TEA UTE

-0.16 UTE UTE 2050 INLET 460HR 43 99 0.39 79 2

SVI 014

+0.73 014 014 4110 OUTLET 520S1 0.39 79 2

TWO 24 014

+0.73 014 014 4110 OUTLET 520SI 43 100 3.07 22 2

TEA UTE

-0.20 UTE UTE 2050 INLET 460HR 43 102 2.17 14 2

TEA UTE

-0.17 UTE UTE 2050 INLET 460HR 43 103 5.45 22 2

TEA UTE

-0.11 UTE UTE 2049 INLET 460HR 43 107 7.51 179 1 ONT LTE

+10.12 LTE LTE 4110 OUTLET 520S1 3.07 29 2

TEA UTE

-0.18 UTE UTE 2049 INLET 460HR 43 109 4.19 340 1 ONT LTE

+10.43 LTE LTE 4110 OUTLET 520S1 7.82 356 1 ONT UTE

-11.30 UTE UTE 4110 OUTLET 520S1 3.21 25 2

TEA UTE

-0.25 UTE UTE 2049 INLET 460HR 43 113 16.83 4

1 SAl UTE

-2.22 UTE UTE 604 INLET 410MB 43 118 6.18 24 2

TEA UTE

-0.34 UTE UTE 2056 INLET 460HR 44 3

1. 61 37 2

TEA UTE

-0.21 UTE UTE 2095 INLET 460HR 9.52 163 1 ONT 010

+0.38 010 010 4042 INLET 460S1 44 4

3.82 25 2

TEA UTE

-0.21 UTE UTE 2094 INLET 460HR 16.11 169 1 DNT 010

+0.10 010 010 4042 INLET 460S1 44 5

2.94 20 2

TEA UTE

-0.23 UTE UTE 2095 INLET 460HR 13.31 170 1 ONT 010

-0.24 010 010 4042 INLET 460SI 0.27 144 2 VOL 008

-0.77 008 008 4042 INLET 460SI 44 6

14.75 169 1 DNT 010

+0.10 010 010 4042 INLET 460S1 44 7

10.72 169 1 DNT 010

-0.55 010 010 4042 INLET 460S1 44 9

4.02 160 1 DNT LTE

+11. 65 LTE LTE 4108 OUTLET 520S1 2.60 178 1 ONT UTE

-13.21 UTE UTE 4042 INLET 460S1 1.53 69 2

SVI 014

+0.76 014 014 4042 INLET 460S1

1. 53 69 2

TWO 48 014

+0.76 014 014 4042 INLET 460S1 0.49 0

P 3 TWO 5 011

+0.66 011 011 WAR 4042 INLET 460S1

1. 03 95 P 3 TWO 10 010

-0.68 010 010 WAR 4042 INLET 460S1 44 11

1. 80 15 2

TEA UTE

-0.17 UTE UTE 2095 INLET 460HR 7.38 173 1 DNT UTE

-13.07 UTE UTE 4042 INLET 460S1 6.68 174 1 ONT UTS

-15.65 UTS UTS 4042 INLET 460SI 4.02 171 1 ONT 015

-17.33 015 015 4042 INLET 460SI 0.12 79 2

VOL 014

+1. 00 014 014 4042 INLET 460S1 0.49 57 P 3 TWO 7 010

+0.49 010 010 WAR 4042 INLET 460S1 5.99 178 1 ONT LTE

+10.72 LTE LTE 4042 INLET 460S1 44 14 2.52 22 2

TEA UTE

-0.19 UTE UTE 2094 INLET 460HR 5.48 170 1 ONT 009

-0.19 009 009 4042 INLET 460SI 44 15

1. 45 76 P 3 TWD 15 010

-0.59 010 010 WAR 4042 INLET 460SI 44 16 5.61 34 2

TEA UTE

-0.16 UTE UTE 2094 INLET 460HR 44 18 2.75 20 2

TEA UTE

-0.27 UTE UTE 2094 INLET 460HR 44 24 1.03 22 2

TEA UTE

-0.17 UTE UTE 2094 INLET 460HR 44 25 0.81 17 2

VOL 014

-6.73 014 014 4042 INLET 460SI 44 26 3.36 24 2

TEA UTE

-0.15 UTE UTE 2094 INLET 460HR 44 27 2.26 21 2

TEA UTE

-0.20 UTE UTE 2095 INLET 460HR 44 29 2.89 20 2

TEA UTE

-0.19 UTE UTE 2095 INLET 460HR 44 31 3.26 28 2

TEA UTE

-0.15 UTE UTE 2095 INLET 460HR 44 32 0.16 133 2 VOL UTE

-3.55 UTE UTS 2094 INLET 460HR 44 33 2.55 21 2

TEA UTE

-0.21 UTE UTE 2094 INLET 460HR 44 35 2.29 30 2

TEA UTE

-0.13 UTE UTE 2095 INLET 460HR 44 37 3.70 27 2

TEA UTE

-0.19 UTE UTE 2095 INLET 460HR 44 40 5.38 172 1 ONT 010

+16.25 010 010 4067 INLET 460S1 44 41 0.64 24 2

SAl UTE

-3.59 UTE UTS 2095 INLET 460HR 0.64 24 2

TWO 63 UTE

-3.59 UTE UTS 2095 INLET 460HR 44 46 2.17 12 2

TEA UTE

-0.22 UTE UTE 2094 INLET 460HR 44 47 2.79 24 2

TEA UTE

-0.14 UTE UTE 2095 INLET 460HR 44 58 2.96 168 1 ONT LTE

+3.76 LTE LTE 4067 INLET 460S1 44 63 8.08 30 2

TEA UTE

-0.10 UTE UTE 2049 INLET 460HR 44 64 2.69 24 2

TEA UTE

-0.15 UTE UTE 2050 INLET 460HR 44 66 4.48 31 2

TEA UTE

-0.19 UTE UTE 2050 INLET 460HR 44 67 3.97 24 2

TEA UTE

-0.11 UTE UTE 2055 INLET 460HR 44 68 4.06 28 2

TEA UTE

-0.25 UTE UTE 2050 INLET 460HR 44 71 3.17 28 2

TEA UTE

-0.21 UTE UTE 2049 INLET 460HR 44 72 7.90 26 2

TEA UTE

-0.20 UTE UTE 2050 INLET 460HR 44 73 4.14 25 2

TEA UTE

-0.20 UTE UTE 2049 INLET 460HR 44 74 4.56 340 1 ONT UTE

-6.59 UTE UTE 4110 OUTLET 520SI 44 77 2.15 345 1 ONT LTE

+11.44 LTE LTE 4110 OUTLET 520SI

1. 38 24 2

TEA UTE

-0.22 UTE UTE 2049 INLET 460HR 44 81 6.96 26 2

TEA UTE

-0.16 UTE UTE 2049 INLET 460HR 44 83 3.46 19 2

TEA UTE

-0.12 UTE UTE 2055 INLET 460HR 44 84 0.13 65 2

VOL UTE

-3.61 UTE UTS 2050 INLET 460HR 44 85 1.25 340 1 ONT LTS

+0.63 LTS LTS 4110 OUTLET 520SI 44 86 2.60 26 2

TEA UTE

-0.15 UTE UTE 2050 INLET 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 87 92 93 95 96 97 98 99 101 102 103 104 105 108 110 111 113 115 116 2

3 5

6 8

12 13 16 19 20 24 30 34 35 38 45 49 53 54 56 P.72 5.45 2.21

1. 66 2.51 3.67 2.76 2.15 2.43 2.57 2.92 1.94 0.13 6.30 7.69 2.04 5.09 6.30 1.20
1. 71 0.13 1.09 0.43 5.13 0.30 0.64 0.00 0.77 1.18 2.20 2.97 3.84 4.72 5.72 5.88 5.53 3.69 2.40 2.35 2.22 2.08 0.00
1. 72 3.04 3.55 2.90 2.28 1.59
1. 33
1. 45 0.00 0.00 3.98 18.78 2.01 12.13 2.24 13.19
1. 78 2.11 0.38 2.30 3.84 2.18 3.99 1.02 3.44 2.26 2.74 2.18 1.36 2.65 1.59 5.40 3.96 10 26 27 17 22 25 21 16 22 26 20 24 1

2 2

2 2

2 2

2 2

2 2

2 2

ONT TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA VOL ONT ONT TEA ONT ONT TEA TEA VOL 70 354 1 355 1 25 2

161 1 341 1 15 2

19 2

75 2

73 P

80 P

357 1 78 2

148 3 TWO 18 3 TWO 8 ONT VOL o

28 25 20 20 21 22 21 21 21 20 25 24 24 26 o

26 19 18 28 32 32 38 38 o o 23 177 28 175 25 174 14 17 30 23 23 25 22 15 26 19 24 22 23 22 16 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 1 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 2

1 2

1 2

1 2

2 TWO 9 TWO 0 16 23 39 49 59 68 77 TWO TWO TWO TWO TWO TWO TWO MCI TWO 75 57 42 41 39 37 o

32 49 55 TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO 48 TWO 40 30 26 28 o o TWO TWO TWO TWO TWO TEA ONT TEA ONT TEA ONT TEA TEA P 3 TWO 4 2

2 2

2 2

2 2

2 2

2 2

2 TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA 22 2

TEA 27 2

TEA LTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS LTE UTE UTE LTE UTE UTE UTE 012 009 010 009 011 008 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 UTE 010 UTE 010 UTE UTE 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE

-0.03

-0.18

-0.18

-0.20

-0.16

-0.19

-0.25

-0.11

-0.08

-0.19

-0.21

-0.21

-4.11

+10.37

-10.91

-0.16

+10.83

-11.26

-0.09

-0.11

+1.07

-0.60

-0.61

-0.45

+0.82

-0.63

-0.23

-0.23

-0.23

-0.23

-0.23

-0.23

-0.23

-0.23

-0.23

-0.23

-0.23

-0.23

-0.23

-0.23

-0.23

-0.30

-0.30

-0.30

-0.30

-0.30

-0.30

-0.23

-0.23

-0.23

-0.23

-0.30

-0.21

-0.01

-0.21

-0.17

-0.17

-0.24

-0.16

-0.16

+0.57

-0.18

-0.13

-0.19

-0.14

-0.16

-0.18

-0.14

-0.11

-0.16

-0.16

-0.21

-0.21

-0.28

-0.15 TO+13.0 TO+21.7 TO+30.4 TO+39.0 TO+47.7 TO+56.4 TO+65.1 TO+73.7 TO+82.4 TO+91.1 TO+99.8 TO+l08.4 TO+117.1 TO+125.8 TO+294.9 TO+303.6 TO+312.3 TO+321.0 TO+329.6 TO+338.3 TO+l34.5 TO+l43.1 TO+l51. 8 TO+l60.5 TO+347.0 05/02/02 13:29:19 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG LTS LTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTS LTE LTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE UTE UTE 012 012 009 009 010 010 009 009 011 011 008 008 UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE 010 010 UTE UTE 010 010 UTE UTE 010 010 UTE UTE UTE UTE 010 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE WAR WAR WAR CL WAR 4110 2050 2049 2049 2050 2049 2050 2049 2049 2050 2049 2050 4110 4110 4110 2050 4110 4110 2049 2050 4110 4110 4110 4110 4110 4130 2126 2126 2126 2126 2126 2126 2126 2126 2126 2126 2126 2126 2126 2126 2126 2126 2126 2126 2126 2126 2126 2126 2126 2126 2126 2126 2094 4042 2095 4042 2094 4042 2094 2094 4042 2095 2094 2095 2094 2094 2094 2094 2095 2094 2095 2095 2094 2126 2095 OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 46 of 155 PROBE 520SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 520SI 520SI 520SI 460HR 520SI 520SI 460HR 460HR 520SI 520SI 520SI 520SI 520SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460SI 460HR 460SI 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR

Framatome ANP Inc.

05/02/02 13:29:19 Customer Name: Oconee Unit 1 Component: 5/G B Page 47 of 155 ATTACHMENT #4 -

LI5T OF IMPERFECTION5 -

MRPC/PLU5 POINT QUERY: QueryM1 ROW TUBE VOLT5 DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

45 59 6.00 28 2

TEA UTE

-0.13 UTE UTE 2095 INLET 460HR 45 63 8.39 25 2

TEA UTE

-0.12 UTE UTE 2050 INLET 460HR 45 65 2.50 28 2

TEA UTE

-0.15 UTE UTE 2049 INLET 460HR 45 70 5.32 26 2

TEA UTE

-0.16 UTE UTE 2049 INLET 460HR 45 72 4.23 26 2

TEA UTE

-0.19 UTE UTE 2049 INLET 460HR 45 77 7.76 26 2

TEA UTE

-0.29 UTE UTE 2050 INLET 460HR 45 80 5.51 173 1 DNT 010

-1. 99 010 010 4111 OUTLET 52051 4.25 20 2

TEA UTE

-0.15 UTE UTE 2055 INLET 460HR 45 82 3.47 23 2

TEA UTE

-0.15 UTE UTE 2049 INLET 460HR 45 84 6.40 28 2

TEA UTE

-0.14 UTE UTE 2049 INLET 460HR 45 86 0.40 77 2

VOL 011

+0.67 011 011 4111 OUTLET 52051 3.77 25 2

TEA UTE

-0.16 UTE UTE 2049 INLET 460HR 45 87 3.22 23 2

TEA UTE

-0.24 UTE UTE 2050 INLET 460HR 45 89 5.50 23 2

TEA UTE

-0.16 UTE UTE 2050 INLET 460HR 45 90 5.01 30 2

TEA UTE

-0.17 UTE UTE 2049 INLET 460HR 45 92 4.10 24 2

TEA UTE

-0.13 UTE UTE 2049 INLET 460HR 45 93 6.83 30 2

TEA UTE

-0.17 UTE UTE 2050 INLET 460HR 45 94

1. 45 161 1 DNT 002

-18.96 002 002 4111 OUTLET 52051 2.80 26 2

TEA UTE

-0.31 UTE UTE 2049 INLET 460HR 45 96 4.09 25 2

TEA UTE

-0.16 UTE UTE 2049 INLET 460HR 45 97 2.58 23 2

TEA UTE

-0.22 UTE UTE 2050 INLET 460HR 45 98 2.50 17 2

TEA UTE

-0.20 UTE UTE 2049 INLET 460HR 45 102

1. 97 23 2

TEA UTE

-0.16 UTE UTE 2049 INLET 460HR 45 105 0.58 91 P 3 TWD 10 008

-0.63 008 008 WAR 4111 OUTLET 52051 45 109 8.93 162 1 DNT LTE

+9.53 LTE LTE 4111 OUTLET 52051 6.76 173 1 DNT UTE

-11. 25 UTE UTE 4111 OUTLET 52051 45 113 0.41 60 P 3 TWD 7 010

+0.43 010 010 WAR 4110 OUTLET 52051 45 115 0.41 73 P 3 TWD 7 009

-0.61 009 009 WAR 4110 OUTLET 52051

1. 47 205 2 TEA UTE

-0.12 UTE UTE 2055 INLET 460HR 45 116 0.74 75 P 3 TWD 13 008

+0.63 008 008 WAR 4110 OUTLET 52051 2.02 22 2

TEA UTE

-0.22 UTE UTE 2056 INLET 460HR 45 117

11. 48 350 1 DNT 009

-0.28 009 009 4110 OUTLET 52051 0.18 73 2

VOL 012

+0.77 012 012 4110 OUTLET 52051 45 118 11.12 175 1 DNT 009

+0.00 009 009 4130 INLET 46051 2.04 22 2

TEA UTE

-0.22 UTE UTE 2056 INLET 460HR 46 3

16.85 168 1 DNT 010

-0.01 010 010 4042 INLET 46051 46 4

1.07 18 2

TEA UTE

-0.26 UTE UTE 2094 INLET 460HR 16.71 175 1 DNT 010

-0.01 010 010 4042 INLET 46051 46 5

18.92 169 1 DNT 010

-0.00 010 010 4042 INLET 46051 46 6

14.80 174 1 DNT 010

-0.00 010 010 4042 INLET 46051 46 9

0.42 137 P 3 TWD 5 010

-0.63 010 010 WAR 4042 INLET 46051 46 13 0.96 15 2

TEA UTE

-0.21 UTE UTE 2094 INLET 460HR 0.32 81 P 3 TWD 4 010

+0.56 010 010 WAR 4036 INLET 46051 46 14 2.09 20 2

TEA UTE

-0.22 UTE UTE 2095 INLET 460HR 0.45 110 P 3 TWD 6 010

+0.45 010 010 WAR 4036 INLET 46051 46 15 3.48 22 2

TEA UTE

-0.24 UTE UTE 2094 INLET 460HR 46 16 3.46 22 2

TEA UTE

-0.25 UTE UTE 2095 INLET 460HR 46 17 2.99 17 2

TEA UTE

-0.22 UTE UTE 2094 INLET 460HR 46 18 3.90 27 2

TEA UTE

-0.18 UTE UTE 2095 INLET 460HR 46 19 3.52 23 2

TEA UTE

-0.24 UTE UTE 2094 INLET 460HR 0.58 91 P 3 TWD 6 008

+0.70 008 008 WAR 4036 INLET 46051 46 20 4.10 25 2

TEA UTE

-0.17 UTE UTE 2095 INLET 460HR 46 21

1. 94 18 2

TEA UTE

-0.18 UTE UTE 2094 INLET 460HR 46 23 3.30 22 2

TEA UTE

-0.17 UTE UTE 2094 INLET 460HR 46 24 4.11 25 2

TEA UTE

-0.27 UTE UTE 2095 INLET 460HR 46 32

1. 61 19 2

TEA UTE

-0.22 UTE UTE 2095 INLET 460HR 46 43 2.90 22 2

TEA UTE

-0.14 UTE UTE 2094 INLET 460HR 46 53 2.15 23 2

TEA UTE

-0.13 UTE UTE 2094 INLET 460HR 46 54 3.95 173 1 DNT LT5

+10.87 LT5 LT5 4067 INLET 46051 46 57 4.01 23 2

TEA UTE

-0.16 UTE UTE 2094 INLET 460HR 46 60 2.13 18 2

TEA UTE

-0.22 UTE UTE 2049 INLET 460HR 46 64

1. 74 19 2

TEA UTE

-0.21 UTE UTE 2049 INLET 460HR 46 67 1.38 17 2

TEA UTE

-0.24 UTE UTE 2050 INLET 460HR 46 68

1. 49 28 2

TEA UTE

-0.28 UTE UTE 2049 INLET 460HR 46 69

1. 02 21 2

MAl UTE

-4.08 UTE UT5 2050 INLET 460HR 1.03 21 2

TWD 58 UTE

-4.08 UTE UT5 2050 INLET 460HR 46 72 1.31 20 2

TEA UTE

-0.19 UTE UTE 2049 INLET 460HR 46 73 2.06 47 2

TEA UTE

-0.11 UTE UTE 2050 INLET 460HR 46 74 4.15 175 1 DNT 005

+4.31 005 005 4111 OUTLET 52051 6.08 29 2

TEA UTE

-0.16 UTE UTE 2049 INLET 460HR 46 78 2.05 20 2

TEA UTE

-0.15 UTE UTE 2049 INLET 460HR 46 80 2.64 32 2

TEA UTE

-0.17 UTE UTE 2049 INLET 460HR 46 82 2.01 12 P 1 5CI UTE

-0.07 UTE UTE CL 2055 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.07 TO+17. 6 UTE UTE 2055 INLET 460HR 0.35 61 P 3 TWD 8 UTE

-0.07 TO+26.3 UTE UTE 2055 INLET 460HR

Framatome ANP Inc.

05/02/02 13:29:20 Customer Name: Oconee Unit 1 Component: S/G B Page 48 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

0.68 0

P 3 TWO 19 UTE

-0.07 To+35.1 UTE UTE 2055 INLET 460HR 0.95 3

P 3 TWO 32 UTE

-0.07 TO+43.9 UTE UTE 2055 INLET 460HR 0.24 33 P 3 TWO 5 UTE

-0.07 TO+52.7 UTE UTE 2055 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.07 TO+61. 5 UTE UTE 2055 INLET 460HR 46 83

1. 94 19 2

TEA UTE

-0.23 UTE UTE 2050 INLET 460HR 46 84 2.28 22 2

TEA UTE

-0.10 UTE UTE 2055 INLET 460HR 46 85 1.31 22 2

TEA UTE

-0.15 UTE UTE 2050 INLET 460HR 46 86 2.14 41 2

TEA UTE

-0.18 UTE UTE 2049 INLET 460HR 46 87 3.18 23 2

TEA UTE

-0.20 UTE UTE 2050 INLET 460HR-46 90

1. 91 16 2

TEA UTE

-0.16 UTE UTE 2049 INLET 460HR 46 91 4.23 19 2

TEA UTE

-0.24 UTE UTE 2050 INLET 460HR 46 94 2.01 19 2

TEA UTE

-0.18 UTE UTE 2049 INLET 460HR 46 95 2.92 20 2

TEA UTE

-0.22 UTE UTE 2050 INLET 460HR 46 96 2.77 23 2

TEA UTE

-0.09 UTE UTE 2055 INLET 460HR 46 97 2.26 37 2

TEA UTE

-0.23 UTE UTE 2050 INLET 460HR 46 98 1.98 24 2

TEA UTE

-0.22 UTE UTE 2049 INLET 460HR 46 99 4.36 37 2

TEA UTE

-0.12 UTE UTE 2050 INLET 460HR 46 100 2.93 18 2

TEA UTE

-0.19 UTE UTE 2049 INLET 460HR 46 101 2.36 21 2

TEA UTE

-0.20 UTE UTE 2050 INLET 460HR 46 102 3.93 27 2

TEA UTE

-0.16 UTE UTE 2049 INLET 460HR 46 103 1.74 16 2

TEA UTE

-0.22 UTE UTE 2050 INLET 460HR 46 105 0.06 85 2

VOL 014

+1.25 014 014 4111 OUTLET 520SI 46 107

1. 93 25 2

TEA UTE

-0.17 UTE UTE 2055 INLET 460HR 46 108 9.21 172 1 ONT LTE

+11. 65 LTE LTE 4111 OUTLET 520SI 8.77 171 1 ONT UTE

-11.89 UTE UTE 4111 OUTLET 520S1 1.06 14 2

TEA UTE

-0.10 UTE UTE 2055 INLET 460HR 46 110 8.66 173 1 ONT LTE

+10.91 LTE LTE 4111 OUTLET 520S1 0.58 56 P 3 TWO 10 008

+0.57 008 008 WAR 4111 OUTLET 520SI 1.13 20 2

TEA UTE

-0.14 UTE UTE 2055 INLET 460HR 46 113 2.63 17 2

TEA UTE

-0.13 UTE UTE 2055 INLET 460HR 46 114 3.70 20 2

TEA UTE

-0.16 UTE UTE 2056 INLET 460HR 46 115 1.16 25 2

TEA UTE

-0.16 UTE UTE 2055 INLET 460HR 46 116 0.24 62 2

VOL 013

+1.10 013 013 4111 OUTLET 520S1

1. 74 19 2

TEA UTE

-0.18 UTE UTE 2056 INLET 460HR 46 117 0.57 97 P 3 TWD 10 007

+0.64 007 007 WAR 4111 OUTLET 520S1 46 118 10.31 170 1 ONT LTE

+11.96 LTE LTE 4111 OUTLET 520S1 9.36 165 1 ONT UTE

-11.43 UTE UTE 4111 OUTLET 520S1 1.23 22 2

TEA UTE

-0.20 UTE UTE 2056 INLET 460HR 47 2

18.71 177 1 DNT 010

+0.00 010 010

  • 4036 INLET 460S1 47 3

16.70 171 1 DNT 010

+0.01 010 010 4042 INLET 460S1 47 4

4.36 31 2

TEA UTE

-0.15 UTE UTE 2095 INLET 460HR 47 5

13.11 171 1 DNT 010

-0.24 010 010 4042 INLET 460S1 47 6

7.15 170 1 DNT 010

-0.44 010 010 4042 INLET 460SI 47 7

6.04 27 2

TEA UTE

-0.10 UTE UTE 2094 INLET 460HR 7.65 167 1 DNT 010

-0.55 010 010 4042 INLET 460SI 47 8

6.16 30 2

TEA UTE

-0.16 UTE UTS 2095 INLET 460HR 47 9

3.95 23 2

TEA UTE

-0.08 UTE UTE 2094 INLET 460HR 47 10 2.70 27 2

TEA UTE

-0.15 UTE UTE 2095 INLET 460HR 47 12 2.42 24 2

TEA UTE

-0.16 UTE UTE 2095 INLET 460HR 47 14 4.42 23 2

TEA UTE

-0.20 UTE UTE 2095 INLET 460HR 47 15 4.05 25 2

TEA UTE

-0.16 UTE UTE 2094 INLET 460HR 47 16 0.61 72 P 3 TWD 7 010

+0.61 010 010 WAR 4036 INLET 460S1 47 17 6.47 23 2

TEA UTE

-0.21 UTE UTE 2094 INLET 460HR 4.82 177 1 ONT LTE

+10.21 LTE LTE 4036 INLET 460S1 47 19 3.90 25 2

TEA UTE

-0.22 UTE UTE 2094 INLET 460HR 47 22

1. 63 22 2

TEA UTE

-0.13 UTE UTE 2095 INLET 460HR 47 25 2.92 21 2

TEA UTE

-0.21 UTE UTE 2095 INLET 460HR 47 26 5.09 23 2

TEA UTE

-0.12 UTE UTE 2094 INLET 460HR 47 29 2.32 26 2

TEA UTE

-0.21 UTE UTE 2095 INLET 460HR 47 31 3.50 27 2

TEA UTE

-0.19 UTE UTE 2095 INLET 460HR 47 36 2.22 20 2

TEA UTE

-0.16 UTE UTE 2094 INLET 460HR 47 39 3.33 26 2

TEA UTE

-0.16 UTE UTE 2095 INLET 460HR 47 40 4.92 28 2

TEA UTE

-0.13 UTE UTE 2094 INLET 460HR 47 42 5.65 25 2

TEA UTE

-0.12 UTE UTE 2094 INLET 460HR 47 43 4.01 29 2

TEA UTE

-0.17 UTE UTE 2095 INLET 460HR 47 45 0.24 117 2 VOL UTS

+3.68 UTS UTS 4067 INLET 460S1 47 47 5.83 29 2

TEA UTE

-0.14 UTE UTE 2095 INLET 460HR 47 51 6.98 184 1 DNT UTS

-17.92 UTS UTS 4067 INLET 460SI 47 58 3.04 23 2

TEA UTE

-0.13 UTE UTE 2094 INLET 460HR 47 66 2.61 32 2

TEA UTE

-0.18 UTE UTE 2050 INLET 460HR 47 67 4.07 24 2

TEA UTE

-0.19 UTE UTE 2049 INLET 460HR 47 68 2.38 25 2

TEA UTE

-0.25 UTE UTE 2050 INLET 460HR 47 69

1. 74 15 2

TEA UTE

-0.15 UTE UTE 2049 INLET 460HR 47 70 1.05 21 2

MAl UTE

-3.66 UTE UTS 2050 INLET 460HR 1.06 21 2

TWO 58 UTE

-3.66 UTE UTS 2050 INLET 460HR

Framatome ANP Inc.

05/02/02 13:29:20 Customer Name: Oconee Unit 1 Component: S/G B Page 49 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -: MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

47 71 4.78 22 2

TEA UTE

-0.12 UTE UTE 2049 INLET 460HR 47 75 2.28 23 2

TEA UTE

-0.23 UTE UTE 2049 INLET 460HR 47 77 4.57 27 2

TEA UTE

-0.22 UTE UTE 2049 INLET 460HR 47 78 0.98 14 P 1 SCI UTE

-3.33 UTE UTS 2050 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.33 TO+101. 0 UTE UTS 2050 INLET 460HR 0.13 1

P 3 TWO 11 UTE

-3.33 TO+109.8 UTE UTS 2050 INLET 460HR 0.16 171 P 3 TWO 12 UTE

-3.33 TO+118.5 UTE UTS 2050 INLET 460HR 0.13 174 P 3 TWO 11 UTE

-3.33 TO+127.3 UTE UTS 2050 INLET 460HR 0.13 161 P 3 TWO 11 UTE

-3.33 TO+136.1 UTE UTS 2050 INLET 460HR 0.23 2

P 3 TWO 16 UTE

-3.33 TO+144.9 UTE UTS 2050 INLET 460HR 0.18 22 P 3 TWO 13 UTE

-3.33 TO+153.7 UTE UTS 2050 INLET 460HR 0.21 25 P 3 TWO 15 UTE

-3.33 TO+162.4 UTE UTS 2050 INLET 460HR 0.44 22 P 3 TWO 28 UTE

-3.33 TO+171.2 UTE UTS 2050 INLET 460HR 0.54 23 P 3 TWO 34 UTE

-3.33 TO+180.0 UTE UTS 2050 INLET 460HR 0.64 18 P 3 TWO 41 UTE

-3.33 TO+188.8 UTE UTS 2050 INLET 460HR 0.68 15 P 3 TWO 45 UTE

-3.33 TO+197.6 UTE UTS 2050 INLET 460HR 0.50 13 P 3 TWO 32 UTE

-3.33 TO+206.3 UTE UTS 2050 INLET 460HR 0.48 21 P 3 TWO 31 UTE

-3.33 TO+215.1 UTE UTS 2050 INLET 460HR 0.49 19 P 3 TWO 31 UTE

-3.33 TO+223.9 UTE UTS 2050 INLET 460HR 0.50 18 P 3 TWO 32 UTE

-3.33 TO+232.7 UTE UTS 2050 INLET 460HR 0.41 20 P 3 TWO 26 UTE

-3.33 TO+241.5 UTE UTS 2050 INLET 460HR 0.33 24 P 3 TWO 21 UTE

-3.33 TO+250.2 UTE UTS 2050 INLET 460HR 0.30 19 P 3 TWO 19 UTE

-3.33 TO+259.0 UTE UTS 2050 INLET 460HR 0.18 33 P 3 TWO 13 UTE

-3.33 TO+267.8 UTE UTS 2050 INLET 460HR 0.18 24 P 3 TWO 13 UTE

-3.33 TO+276.6 UTE UTS 2050 INLET 460HR 0.20 16 P 3 TWO 14 UTE

-3.33 TO+285.4 UTE UTS 2050 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.33 TO+294.1 UTE UTS 2050 INLET 460HR 47 83 2.81 20 2

TEA UTE

-0.17 UTE UTE 2049 INLET 460HR 47 85 12.38 177 1 ONT LTS

-10.67 LTS LTS 4111 OUTLET 520SI 7.79 177 1 ONT LTS

-9.84 LTS LTS 4111 OUTLET 520SI 10.28 175 1 ONT UTE

-11. 98 UTE UTE 4111 OUTLET 520S1 2.66 25 2

TEA UTE

-0.20 UTE UTE 2049 INLET 460HR 47 87 4.37 29 2

TEA UTE

-0.24 UTE UTE 2049 INLET 460HR 47 88 1.15 19 2

TEA UTE

-0.23 UTE UTE 2050 INLET 460HR 47 89 3.18 23 2

TEA UTE

-0.27 UTE UTE 2049 INLET 460HR 47 90 2.77 29 2

TEA UTE

-0.22 UTE UTE 2050 INLET 460HR 47 91 4.11 27 2

TEA UTE

-0.22 UTE UTE 2049 INLET 460HR 47 92 3.77 20 2

TEA UTE

-0.27 UTE UTE 2050 INLET 460HR 47 93 4.33 33 2

TEA UTE

-0.50 UTE UTE 2049 INLET 460HR 47 94 2.04 13 2

TEA UTE

-0.18 UTE UTE 2050 INLET 460HR 47 95 3.25 22 2

TEA UTE

-0.22 UTE UTE 2049 INLET 460HR 47 96 3.11 28 2

TEA UTE

-0.18 UTE UTE 2050 INLET 460HR 47 97 4.25 29 2

TEA UTE

-0.14 UTE UTE 2049 INLET 460HR 47 98 2.10 33 2

TEA UTE

-0.19 UTE UTE 2050 INLET 460HR 47 100 3.80 21 2

TEA UTE

-0.22 UTE UTE 2050 INLET 460HR 47 101 4.67 27 2

TEA UTE

-0.23 UTE UTE 2049 INLET 460HR 47 102 2.32 31 2

TEA UTE

-0.28 UTE UTE 2050 INLET 460HR 47 103 4.54 31 2

TEA UTE

-0.20 UTE UTE 2049 INLET 460HR 47 104 5.27 28 2

TEA UTE

-0.24 UTE UTE 2050 INLET 460HR 47 105 1.88 26 2

TEA UTE

-0.19 UTE UTE 2049 INLET 460HR 47 108

1. 54 27 P 1 SCI UTE

-0.34 UTE UTS CL 2049 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.34 TO+57.1 UTE UTS 2049 INLET 460HR 1.15 11 P 3 TWO 53 UTE

-0.34 TO+65.9 UTE UTS 2049 INLET 460HR

1. 49 21 P 3 TWO 68 UTE

-0.34 TO+74.6 UTE UTS 2049 INLET 460HR 0.74 24 P 3 TWO 34 UTE

-0.34 TO+83.4 UTE UTS 2049 INLET 460HR 0.18 66 P 3 TWO 5 UTE

-0.34 TO+92.2 UTE UTS 2049 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.34 TO+101.0 UTE UTS 2049 INLET 460HR 47 111

11. 44 170 1 ONT LTE

+11.81 LTE LTE 4111 OUTLET 520SI 4.37 173 1 ONT LTE

+11.14 LTE LTE 4111 OUTLET 520SI 47 112 3.09 33 2

TEA UTE

-0.16 UTE UTE 2049 INLET 460HR 47 113 2.17 26 2

TEA UTE

-0.16 UTE UTE 2050 INLET 460HR 47 114 0.56 82 P 3 TWO 10 009

-0.48 009 009 WAR 4111 OUTLET 520SI 2.76 22 2

TEA UTE

-0.19 UTE UTE 2049 INLET 460HR 47 115 0.80 101 P 3 TWO 14 009

-0.49 009 009 WAR 4111 OUTLET 520S1 3.37 28 2

TEA UTE

-0.25 UTE UTE 2050 INLET 460HR 47 116 0.23 89 2

VOL 014

+0.85 014 014 4111 OUTLET 520S1 2.63 29 2

TEA UTE

-0.18 UTE UTE 2055 INLET 460HR 47 118 3.95 31 2

TEA UTE

-0.13 UTE UTE 2055 INLET 460HR 47 119 3.72 26 2

TEA UTE

-0.15 UTE UTE 2056 INLET 460HR 47 120

1. 86 23 2

TEA UTE

-0.17 UTE UTE 2055 INLET 460HR 47 122 10.13 168 1 ONT LTE

+12.03 LTE LTE 4111 OUTLET 520SI 5.45 172 1 ONT UTE

-10.56 UTE UTE 4130 INLET 460S1 8.37 174 1 ONT 010

-0.19 010 010 4130 INLET 460S1 2.14 27 2

TEA UTE

-0.21 UTE UTE 2056 INLET 460HR 48 2

19.59 178 1 ONT 010

-0.04 010 010 4036 INLET 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 3

4 5

6 7

8 10 11 12 17 19 20 22 25 26 27 30 37 39 41 44 45 49 51 52 55 58 64 69 71 73 75 76 77 82 84 86 87 88 91 93 96 101 105 108 110 115 19.41 10.77 16.43 17.34 4.24 8.42 2.54 3.14

1. 43 1.00 2.01 2.55 2.73 5.33 3.47 0.10 3.31
1. 93 4.63 2.24 4.72 0.34 0.34 0.34 2.61 3.48 3.70 2.40 7.60
1. 39 0.22 2.95 8.94 3.29
1. 43 0.77 2.97 2.98
1. 33 0.74 3.80 0.51 0.51 1.23 2.49 5.21 10.64 7.67 6.72 7.79 6.04 4.03 7.04 5.69 2.79 0.00 0.22 0.30 0.41 0.40 0.36 0.32 0.31 0.22 0.18 0.18 0.15 0.22 0.00 0.48 2.48 3.46 2.64 2.15 0.68 183 1 ONT 178 1 ONT 172 1 ONT 170 1 ONT 26 2

TEA 169 1 ONT 21 2

TEA 17 2

TEA 108 P 3 TWO 15 61 P 3 TWO 11 17 2

TEA 20 2

TEA 17 2

TEA 29 2

TEA 172 1 ONT 50 2

VOL 34 2

TEA 22 2

TEA 27 2

TEA 27 2

TEA 25 2

TEA 19 2

MAl 17 2

TWO 48 19 2

TWO 56 25 2

TEA 24 2

TEA 32 2

TEA 19 2

TEA 27 2

TEA 24 2

TEA 77 P 3 TWO 4 19 2

TEA 171 1 ONT 20 2

TEA 18 2

MAl 25 2

TWO 68 27 2

TEA 28 2

TEA 16 2

MAl 32 2

TWO 84 19 2

TEA 17 2

MAl 17 2

TWO 47 70 P 3 TWO 17 177 1 ONT 186 1 ONT 182 1 ONT 180 1 ONT 177 1 ONT 185 1 ONT 173 1 ONT 22 2

TEA 24 2

TEA 22 2

TEA 19 2

TEA o

P 3 TWO 0 17 P 3 TWO 59 28 P 3 TWO 71 25 P 3 TWO 86 27 P 3 TWO 84 19 P 3 TWO 80 24 P 3 TWO 75 24 P 3 TWO 74 23 P 3 TWO 59 20 P 3 TWO 50 31 P 3 TWO 50 10 P 3 TWO 44 4

P 3 TWO 58 o

P 3 TWO 0 24 P 1 SCI 21 2

TEA 25 2

TEA 27 2

TEA 21 2

TEA 79 P 3 TWO 10 010 010 010 010 UTE 010 UTE UTE 010 010 UTE UTE UTE UTE 004 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 007 UTE 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 007 UTS UTE LTE LTE UTE UTE LTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009

-0.49

+0.51

-0.47

+0.53

-0.19

-0.57

-0.21

-0.18

-0.68

-0.73

-0.14

-0.21

-0.12

-0.24

-8.39

+1.22

-0.15

-0.22

-0.19

-0.22

-0.24

-3.53

-3.53

-3.50

-0.19

-0.17

-0.12

-0.12

-0.13

-0.15

-0.07

-0.12

-17.01

-0.11

-3.48

-3.48

-0.20

-0.27

-3.63

-3.63

-0.18

-3.90

-3.90

-0.31

-7.17

-12.02

+13.33

+14.09

-12.36

-11. 65

-10.60

-0.18

-0.18

-0.21

-0.26

-3.69

-3.69

-3.69

-3.69

-3.69

-3.69

-3.69

-3.69

-3.69

-3.69

-3.69

-3.69

-3.69

-3.69

-3.69

-0.20

-0.26

-0.28

-0.22

-0.29 TO+30.7 TO+39.5 TO+48.3 TO+57.1 TO+65.9 TO+74.6 TO+83.4 TO+92.2 TO+101. 0 TO+l09.8 TO+118.5 TO+127.3 TO+136.1 TO+144.9 05/02/02 13:29:21 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG 010 010 010 010 010 010 010 010 UTE UTE 010 010 UTE UTE UTE UTE 010 010 010 010 UTE UTE UTE UTE UTE UTE UTE UTE 004 004 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 007 007 UTE UTE 010 010 UTE UTE UTE UTS UTE UTS UTE UTE UTE UTE UTE UTS UTE UTS UTE UTE UTE UTS UTE UTS 007 007 UTS UTS UTE UTE LTE 001 LTE 001 UTE UTE UTE UTE LTS LTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE UTE UTE UTE UTE UTE UTE 009 009 WAR WAR WAR WAR TR WAR 4127 4127 4036 4036 2091 4036 2090 2091 4036 4036 2090 2091 2090 2091 4036 4036 2090 2090 2091 2090 2095 2094 2094 2094 2095 2095 2095 2094 2095 2095 4067 2094 4067 2094 2050 2050 2050 2050 2050 2050 2050 2055 2055 4112 4115 4112 4133 4133 4130 4130 4130 2055 2050 2049 2049 2049 2049 2049 2049 2049 2049 2049 2049 2049 2049 2049 2049 2049 2049 2049 2050 2050 2049 2049 4112 OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET Page 50 of 155 PROBE 460SI 46081 460SI 46081 460HR 460SI 460HR 460HR 460SI 460SI 460HR 460HR 460HR 460HR 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 520SI 520SI 520SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 520SI

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION 48 48 48 48 48 48 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 116 117 118 119 122 123 1

3 5

6 8

10 11 13 14 15 16 19 22 23 28 32 33 34 38 40 44 49 51 53 56 0.08 2.80 2.19 0.96 0.26 2.37 0.00 0.58 1.50 2.30

1. 40 0.42 0.00 5.48 9.22 2.80 0.00 0.19 0.40 0.58 1.18 2.23 2.63 2.17 1.67 1.13 0.74 8.12 2.29 15.04 5.27 0.00 2.30 2.83 3.98 5.11 4.73 3.02 2.42 2.83 2.39 1.44 0.00 19.17 5.51 5.76 15.96 6.57 4.48 2.45 4.39 1.32 3.21 3.69 2.78 0.66 3.58 0.88 0.39 3.10 2.16 2.71 0.41 2.28 3.65 3.77 2.46 2.44 2.38 2.66 3.46 4.64 2.10 2.92 3.04 62 29 24 57 151 26 o

8 15 19 18 5 o 175 180 20 o

19 25 27 7

14 20 21 15 8

10 171 25 175 29 o

10 16 18 20 20 20 14 12 10 6 o 349 23 176 175 174 23 27 19 74 22 23 30 122 21 94 92 21 13 21 85 27 24 34 20 23 18 17 19 27 29 27 27 2

VOL 2

TEA 2

TEA P 3 TWO 13 P 3 TWO 7 P 1 SCI P 3 TWO 0 P 3 TWO 19 P 3 TWO 47 P 3 TWO 67 P 3 TWO 45 P 3 TWO 13 P 3 TWO 0 1

ONT 1

ONT P 1 SCI P 3 TWO 0 P 3 TWO 1 P 3 TWO 5 P 3 TWO 9 P 3 TWO 24 P 3 TWO 57 P 3 TWO 73 P 3 TWO 55 P 3 TWO 38 P 3 TWO 23 P 3 TWO 0 1

ONT 2

TEA 1

ONT P 1 SCI P 3 TWO 0 P 3 TWO 30 P 3 TWO 37 P 3 TWO 53 P 3 TWO 72 p*3 TWO 66 P 3 TWO 39 P 3 TWO 31 P 3 TWO 37 P 3 TWO 31 P 3 TWO 19 P 3 TWO 0 1

ONT 2

TEA 1

ONT 1

ONT 1

ONT 2

TEA 2

TEA 2

TEA P 3 TWO 14 2

TEA 2

TEA 2

TEA P 3 TWO 7 2

TEA P 3 TWO 9 P 3 TWO 4 2

TEA 2

TEA 2

TEA P 3 TWO 5 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 014 UTE UTE 008 008 UTE UTE UTE UTE UTE UTE UTE UTE 009 009 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 UTE 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 UTE UTE 010 LTE UTE UTE UTE 010 UTE UTE UTE 010 UTE 008 008 UTE UTE UTE 008 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE

+1.15

-0.21

-0.15

-0.72

+0.65

-0.40

-0.40

-0.40

-0.40

-0.40

-0.40

-0.40

-0.40

+0.29

+0.42

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.69

-0.15

-0.01

-0.16

-0.16

-0.16

-0.16

-0.16

-0.16

-0.16

-0.16

-0.16

-0.16

-0.16

-0.16

-0.16

+0.10

-0.21

-12.16

-0.23

+11. 40

-0.17

-0.19

-0.24

-0.70

-0.13

-0.17

-0.17

+0.60

-0.20

-0.62

+0.65

-0.19

-0.20

-0.19

+0.55

-0.22

-0.15

-0.18

-0.15

-0.16

-0.19

-0.14

-0.16

-0.16

-0.17

-0.18

-0.12 TO+355.5 TO+4.5 TO+13.5 TO+22.5 TO+31.5 T0+40.5 TO+49.5 TO+310.5 TO+319.5 TO+328.5 TO+337.5 TO+346.5 TO+355.5 TO+4.5 TO+13.5 TO+22.5 TO+31.5 TO+40.5 TO+274.5 TO+283.5 TO+292.5 TO+301. 5 TO+310.5 TO+319.5 TO+328.5 TO+337.5 TO+346.5 TO+355.5 TO+4.5 TO+13.5 05/02/02 13:29:21 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG 014 014 UTE UTE UTE UTE 008 008 008 008 UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS 009 009 009 009 UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS 010 010 UTE UTE 010 010 UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS 010 010 UTE UTE UTE UTE 010 010 LTE LTE UTE UTE UTE UTE UTE UTE 010 010 UTE UTE UTE UTE UTE UTE 010 010 UTE UTE 008 008 008 008 UTE UTE UTE UTE UTE UTE 008 008 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE WAR WAR CL CL CL WAR WAR WAR WAR WAR 4112 2055 2055 4112 4112 2056 2056 2056 2056 2056 2056 2056 2056 4112 4130 2056 2056 2056 2056 2056 2056 2056 2056 2056 2056 2056 2056 4112 2055 4130 2056 2056 2056 2056 2056 2056 2056 2056 2056 2056 2056 2056 2056 4071 2091 4036 4036 4036 2091 2090 2090 4036 2090 2091 2091 4036 2090 4036 4036 2091 2090 2091 4036 2091 2090 2090 2091 2090 2090 2090 2090 2091 2091 2091 2090 OUTLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 51 of 155 PROBE 520SI 460HR 460HR 520SI 520SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 520SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 520SI 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460SI 460SI 460SI 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460SI 460HR 460SI 460SI 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR

Framatome ANP Inc.

05/02/02 13:29:22 Customer Name: Oconee Unit 1 Component: S/G B Page 52 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

49 60 2.84 178 1 DNT LTS

+12.83 LTS LTS 4067 INLET 460SI 2.46 179 1 DNT LTS

+15.14 LTS LTS 4067 INLET 460SI 49 61 3.13 22 2

TEA UTE

-0.14 UTE UTE 2099 INLET 460HR 49 64

1. 98 37 2

TEA UTE

-0.25 UTE UTE 2050 INLET 460HR 49 67 2.30 21 2

TEA UTE

-0.19 UTE UTE 2049 INLET 460HR 49 68 1.11 25 2

TEA UTE

-0.27 UTE UTE 2050 INLET 460HR 49 69 2.67 31 2

TEA UTE

-0.23 UTE UTE 2049 INLET 460HR 49 71 5.92 28 2

TEA UTE

-0.19 UTE UTE 2049 INLET 460HR 49 72 2.23 38 2

TEA UTE

-0.12 UTE UTE 2050 INLET 460HR 49 73

1. 74 18 2

TEA UTE

-0.15 UTE UTE 2055 INLET 460HR 49 74 3.14 25 2

TEA UTE

-0.25 UTE UTE 2056 INLET 460HR 49 75 5.49 30 2

TEA UTE

-0.13 UTE UTE 2055 INLET 460HR 49 77 2.76 19 2

TEA UTE

-0.14 UTE UTE 2055 INLET 460HR 49 80 3.28 28 2

TEA UTE

-0.13 UTE UTE 2055 INLET 460HR 49 81 0.76 10 2

TEA UTE

-0.20 UTE UTE 2056 INLET 460HR 49 82 1.43 23 2

TEA UTE

-0.08 UTE UTE 2055 INLET 460HR 49 83 2.B8 26 2

TEA UTE

-0.30 UTE UTE 2056 INLET 460HR 49 84 2.69 22 2

TEA UTE

-0.17 UTE UTE 2055 INLET 460HR 49 B5 10.00 179 1 DNT LTS

-10.33 LTS LTS 4114 OUTLET 520SI 6.71 35B 1 DNT UTE

-11.10 UTE UTE 4130 INLET 460SI 2.21 33 2

TEA UTE

-0.25 UTE UTE 2056 INLET 460HR 49 86 7.03 173 1 DNT LTS

-9.87 LTS LTS 4114 OUTLET 520SI 5.59 172 1 DNT UTE

-11. 59 UTE UTE 4130 INLET 460SI 49 88 5.80 24 2

TEA UTE

-0.15 UTE UTE 2055 INLET 460HR 49 89 3.48 22 2

TEA UTE

-0.20 UTE UTE 2056 INLET 460HR 49 91 2.43 17 2

TEA UTE

-0.25 UTE UTE 2056 INLET 460HR 49 96 0.69 12 2

TEA UTE

-0.16 UTE UTE 2055 INLET 460HR 49 101 3.78 19 2

TEA UTE

-0.14 UTE UTE 2055 INLET 460HR 49 103 2.08 28 2

TEA UTE

-0.16 UTE UTE 2055 INLET 460HR 49 104 1.60 21 2

TEA UTE

-0.28 UTE UTE 2056 INLET 460HR 49 105 2.52 19 2

TEA UTE

-0.13 UTE UTE 2055 INLET 460HR 49 113 2.43 21 2

TEA UTE

-0.17 UTE UTE 2055 INLET 460HR 49 114 0.63 72 P 3 TWD 11 010

-0.73 010 010 WAR 4114 OUTLET 520SI 49 115

1. 96 23 2

TEA UTE

-0.15 UTE UTE 2055 INLET 460HR 49 116 0.4B 75 P 3 TWD 9 008

-0.71 008 008 WAR 4114 OUTLET 520SI 0.47 103 P 3 TWD 8 008

+0.6B OOB OOB WAR 4114 OUTLET 520SI 49 117 0.18 76 P 3 TWD 3 008

-0.6B 008 OOB WAR 4114 OUTLET 520SI 5.74 168 1 DNT 009

+0.62 009 009 4114 OUTLET 520SI

1. 61 20 2

TEA UTE

-0.16 UTE UTE 2055 INLET 460HR 49 121 3.68 175 1 DNT LTE

+12.37 LTE LTE

\\ 4114 OUTLET 520SI 0.49 73 P 3 TWD 9 010

-0.69 010 010 WAR 4114 OUTLET 520SI 8.53 169 1 DNT UTE

-11. 92 UTE UTE 4114 OUTLET 520SI 49 122 7.B5 175 1 DNT LTE

+8.01 LTE LTE 4114 OUTLET 520SI 6.49 175 1 DNT LTE

+12.39 LTE LTE 4114 OUTLET 520SI 4.B5 175 1 DNT 010

-0.57 010 010 4114 OUTLET 520SI 0.52 81 P 3 TWO 9 010

+0.75 010 010 WAR 4114 OUTLET 520SI 0.12 99 2

VOL 014

+0.84 014 014 4114 OUTLET 520SI 0.08 92 2

VOL 014

+1.29 014 014 4114 OUTLET 520SI 9.51 1

1 DNT UTE

-8.93 UTE UTE 4130 INLET 460SI 5.78 182 1 DNT UTE

-12.15 UTE UTE 4130 INLET 460SI 5.57 24 2

TEA UTE

-0.26 UTE UTE 2056 INLET 460HR 49 124 0.16 119 2 VOL 015

-0.60 015 015 4114 OUTLET 520SI 13.02 172 1 DNT 010

-0.2B 010 010 4130 INLET 46081 50 4

1.26 29 2

TEA UTE

-0.19 UTE UTE 2091 INLET 460HR 50 5

0.44 76 2

VOL 013

+1.44 013 013 4036 INLET 46081 0.16 90 2

VOL 013

+1. OB 013 013 4036 INLET 46081 50 8

3.40 32 2

TEA UTE

-0.24 UTE UTE 2091 INLET 460HR 50 10 2.58 25 2

TEA UTE

-0.21 UTE UTE 2091 INLET 460HR 50 11 4.19 24 2

TEA UTE

-0.22 UTE UTE 2090 INLET 460HR 50 12 3.61 1B 2

TEA UTE

-0.22 UTE UTE 2090 INLET 460HR 50 14 5.71 166 1 DNT 010

-4.37 010 010 4036 INLET 46081 5.62 168 1 DNT 009

+11. 85 009 009 4036 INLET 460SI 1.05 87 P 3 TWD 11 OOB

-0.68 008 008 WAR 4036 INLET 460SI 50 15 2.39 19 2

TEA UTE

-0.17 UTE UTE 2090 INLET 460HR 50 17 3.90 31 2

TEA UTE

-0.19 UTE UTE 2090 INLET 460HR 50 18 2.54 17 2

TEA UTE

-0.18 UTE UTE 2091 INLET 460HR 50 19 2.94 23 2

TEA UTE

-0.15 UTE UTE 2090 INLET 460HR 50 20 4.53 28 2

TEA UTE

-0.17 UTE UTE 2091 INLET 460HR 50 22 2.99 22 2

TEA UTE

-0.20 UTE UTE 2091 INLET 460HR 50 26 2.77 30 2

TEA UTE

-0.18 UTE UTE 2091 INLET 460HR 50 27

1. 90 11 2

TEA UTE

-0.17 UTE UTE 2090 INLET 460HR 50 30 4.24 21 2

TEA UTE

-0.17 UTE UTE 2091 INLET 460HR 50 31 2.08 21 2

TEA UTE

-0.21 UTE UTE 2090 INLET 460HR 50 36 2.85 26 2

TEA UTE

-0.14 UTE UTE 2091 INLET 460HR 50 37 4.42 178 1 DNT LT8

+8.59 LT8 LT8 4067 INLET 46081

Framatome ANP Inc.

Customer Name: Oconee unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMI ROW TUBE VOLTS DEG CHN IND %TW LOCATION 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 42 47 50 51 52 57 60 61 62 63 64 65 66 67 68 77 78 86 88 89 90 95 96 97 98 100 101 104 105 106 107 108 109 110 112 115 123 4.02 0.84 0.84 8.03 2.84

1. 63 9.12 3.05 9.84 0.16 0.16 4.23 1.36 1.36 5.78 0.78 0.78 2.80 2.55 3.09 1.02 1.02 3.09 5.23 2.22
1. 33 0.57 0.57 2.60 0.62 0.00 0.38 0.34 0.38 0.51 0.47 0.41 0.39 0.43 0.52 0.58 0.51 0.37 0.49 0.51 0.48 0.46 0.52 0.35 0.29 0.30 0.29 0.00 1.56 2.50 2.38 3.97 2.12 6.65 7.49
1. 84 7.65 0.16 7.31 4.76 6.03 2.05 2.83 2.63 0.34 0.74 4.08 0.31 7.66 6.94 TEA SVI UTE UTE 20 2

29 2

29 2

173 1 23 2

24 2

173 1 26 2

23 2

76 2

76 2

24 2

26 2

26 2

23 2

16 2

16 2

21 2

28 2

23 2

15 2

15 2

23 2

23 2

18 2

21 2

20 2

20 2

20 2

23 TWD 100 UTE DNT 009 o

17 19 16 14 16 22 20 20 20 14 15 17 15 16 14 16 13 17 11 18 12 o

22 30 20 19 30 179 175 21 176 77 176 26 26 20 26 21 55 69 183 82 167 166 TEA TEA DNT TEA TEA SAl TWD 35 TEA SAl TWD 71 TEA SAl TWD 33 TEA TEA TEA SAl TWD 30 TEA TEA TEA TEA SAl TWD 46 TEA P 1 SCI P 3 TWD 0 P 3 TWD 23 P 3 TWD 21 P 3 TWD 24 P 3 TWD 32 P 3 TWD 29 P 3 TWD 26 P 3 TWD 24 P 3 TWD 27 P 3 TWD 32 P 3 TWD 36 P 3 TWD 32 P 3 TWD 23 P 3 TWD 31 P 3 TWD 32 P 3 TWD 30 P 3 TWD 29 P 3 TWD 32 P 3 TWD 22 P 3 TWD 18 P 3 TWD 18 P 3 TWD 17 P 3 TWD 0 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 1

DNT 1

DNT 2

TEA 1

DNT 2

VOL 1

DNT 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA P 3 TWD 6 P 3 TWD 13 1

DNT P 3 TWD 6 1

DNT 1

DNT UTE UTE 002 UTE UTE 010 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE UTE UTE LTE 014 UTE UTE UTE UTE UTE UTE 008 010 009 010 LTE LTE

-0.16

-0.79

-0.79

+13.26

-0.24

-0.21

-15.38

-0.17

-0.11

-9.77

-9.77

-0.14

-3.34

-3.34

-0.17

-3.57

-3.57

-0.17

-0.15

-0.20

-2.38

-2.38

-0.20

-0.15

-0.16

-0.13

-1. 2B

-1. 28

-0.17

-3.11

-3.11

-3.11

-3.11

-3.11

-3.11

-3.11

-3.11

-3.11

-3.11

-3.11

-3.11

-3.11

-3.11

-3.11

-3.11

-3.11

-3.11

-3.11

-3.11

-3.11

-3.11

-3.11

-3.11

-0.14

-0.11

-0.16

-0.20

-0.14

+11. 80

-11. 74

-0.19

+12.16

+1. 03

-11. 67

-0.19

-0.15

-0.19

-0.18

-0.27

-0.70

-0.04

+0.45

+0.36

+7.83

+11.0B TO+213.3 TO+222.2 TO+231.1 TO+240.0 TO+24B.9 TO+257.8 TO+266.7 TO+275.6 TO+284.4 TO+293.3 TO+302.2 TO+311.1 To+320.0 TO+328.9 To+337.8 TO+346.7 TO+355.6 TO+4.4 TO+13.3 TO+22.2 TO+31.1 T0+40.0 TO+48.9 05/02/02 13:29:22 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE UTE UTE 009 009 UTE UTE UTE UTE 002 002 UTE UTE UTE UTE 010 010 010 010 UTE UTE UTE UTS UTE UTS UTE UTE UTE UTS UTE UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE LTE LTE 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 008 OOB 010 010 009 009 010 010 LTE LTE LTE LTE TR TR WAR WAR WAR 2091 2090 2090 4067 2090 2091 4067 2099 2098 4124 4124 2055 2056 2056 2055 2056 2056 2055 2055 2056 2056 2056 2055 2055 2055 2056 2056 2056 2055 2055 2055 2055 2055 2055 2055 2055 2055 2055 2055 2055 2055 2055 2055 2055 2055 2055 2055 2055 2055 2055 2055 2055 2055 2055 2055 2056 2056 2055 4114 4114 2056 4114 4114 4114 2056 2055 2056 2055 2056 4114 4114 4114 4114 4114 4114 INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET Page 53 of 155 PROBE 460HR 460HR 460HR 460SI 460HR 460HR 460S1 460HR 460HR 520S1 520S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 520SI 520S1 460HR 520S1 520S1 520S1 460HR 460HR 460HR 460HR 460HR 520S1 520S1 520SI 520SI 520SI 520SI

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS ~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51

. 51 1

6 9

12 13 14 17 18 21 22 23 26 27 28 29 31 32 34 37 39 40 55 65 67 68 72 73 74 76 77 80 81 83 86 92 93 94 95 96 98 99 100 101 102 103 104 106 107 108 109 7.83 7.51 7.55 4.19 8.10 8.08 0.48 10.11 0.25 0.70

1. 80 0.45 0.58 2.59 3.90 2.35 0.37 0.37 2.80
1. 50 2.83 4.84 2.14 0.89 2.60 0.38 8.33 2.11 4.34 0.54 0.18 4.89 4.79 0.58 4.58 3.41 0.21 3.24 7.70 0.20 3.23 3.84 4.60 3.12 2.16 1.28 3.40 3.33 1.40 4.15 3.10 1.54
1. 93 2.55 2.48 0.11 2.27 5.49 6.92 6.38 0.39 6.96 2.40 5.50 7.17 2.16 6.17 6.58 0.99 0.80 0.00 0.26 0.67 0.87 0.65 ONT ONT ONT TEA ONT ONT VOL ONT PLP 170 1 172 1 166 1 22 2

169 1 170 1 62 2

171 1 91 9

147 17 101 75 P 3 TWO 8 2

TEA 22 25 28 25 25 21 28 22 29 21 19 17 25 27 22 25 43 19 25 18 107 25 27 49 172 24 P 3 TWO 6 P 3 TWO 6 2

TEA 2

TEA 2

TEA 2

SAl 2

TWO 82 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA P 3 TWO 7 2

TEA 2

TEA 2

TEA 2

TEA P 3 TWO 4 2

TEA 2

TEA P 3 TWO 11 2

TEA 2

TEA P 3 TWO 6 1

ONT 2

TEA 3 TWO 6 TEA ONT TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA VOL TEA ONT ONT ONT 3 TWO 11 79 P

17 2

166 1 15 2

25 2

21 2

14 2

22 2

21 2

17 2

23 2

28 2

23 2

25 2

27 2

28 2

99 2

24 2

176 1 178 1 173 1 110 P 173 1 24 2

176 1 176 1 20 2

172 1 172 1 27 2

26 P 1 P 3 P 3 P 3 P 3 P 3 ONT TEA ONT ONT TEA ONT ONT TEA SCI o

12 17 16 17 TWO 0 17 44 54 44 TWO TWO TWD TWO UTE UTE 010 UTE UTS UTS 001 LTE 014 010 UTE 010 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 011 UTE UTE UTE UTE 007 UTE UTE 007 UTE UTE 007 UTS UTE 007 UTE 005 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 UTE LTE UTE LTE 008 UTE UTE LTE UTE UTE LTE UTE UTE UTE UTE UTE UTE UTE UTE

-10.54

-8.04

-0.03

-0.27

+11.72

+12.20

+0.80

+11.35

+0.89

+0.74

-0.15

+0.67

-0.71

-0.07

-0.13

-0.14

-3.67

-3.67

-0.15

-0.16

-0.14

-0.17

-0.21

-0.15

-0.21

+0.77

-0.13

-0.12

-0.11

-0.08

+0.43

-0.12

-0.15

-0.33

-0.23

-0.12

-0.40

+7.69

-0.17

-0.49

-0.15

+7.84

-0.18

-0.11

-0.16

-0.22

-0.18

-0.17

-0.15

-0.18

-0.18

-0.22

-0.20

-0.24

-0.14

+1.11

-0.19

+11. 04

-11.57

+11. 25

-0.62

-11. 31

-0.17

+11.14

-11. 72

-0.19

+10.43

-10.81

-0.13

-1. 37

-1. 37

-1. 37

-1.37

-1.37

-1. 37 TO+328.1 TO+337.2 TO+346.3 TO+355.4 TO+4.6 05/02/02 13:29:23 Component: 8/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE 010 010 UTE UTE UTE UTS UTE UTS 002 001 LTS LTE 014 014 010 010 UTE UTE 010 010 010 010 UTE UTE UTE UTE UTE UTE UTE UT8 UTE UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 011 011 UTE UTE UTE UTE UTE UTE UTE UTE 007 007 UTE UTE UTE UTE 007 007 UTE UTE UTE UTE 007 007 UTS UTS UTE UTE 007 007 UTE UTE 005 005 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 014 UTE UTE LTE LTE UTE UTE LTE LTE 008 008 UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UT8 UTE UTS WAR WAR WAR WAR WAR WAR WAR WAR WAR TR 4114 4114 4130 2056 4071 4071 4071 4071 4036 4036 2090 4036 4036 2090 2090 2091 2090 2090 2091 2090 2091 2090 2091 2090 2090 4067 2091 2090 2090 2090 4067 2055 2055 4124 2056 2055 4115 4115 2056 4115 2055 4115 2056 2055 2055 2056 2056 2055 2056 2055 2056 2056 2055 2056 2055 4115 2055 4115 4115 4115 4115 4115 2055 4115 4115 2056 4115 4115 2055 2056 2056 2056 2056 2056 2056 OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET OUTLET OUTLET INLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET Page 54 of 155 PROBE 520SI 520SI 46081 460HR 46081 46081 460SI 460SI 46081 460SI 460HR 460SI 46081 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460SI 460HR 460HR 520SI 460HR 460HR 520S1 520SI 460HR 520SI 460HR 52081 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 520SI 460HR 520SI 520S1 52081 52081 520SI 460HR 52081 52081 460HR 52081 520SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR

Framatome ANP Inc.

05/02/02 13:29:23 Customer Name: Oconee Unit 1 Component: S/G B Page 55 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

0.28 15 P 3 TWO 19 UTE

-1. 37 TO+13.7 UTE UTS 2056 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-1. 37 TO+22.8 UTE UTS 2056 INLET 460HR 51 110 4.60 24 2

TEA UTE

-0.17 UTE UTE 2055 INLET 460HR 51 111 0.32 105 P 3 TWO 9 008

-0.70 008 008 WAR 4115 OUTLET 520SI 51 112 1.79 25 2

TEA UTE

-0.16 UTE UTE 2055 INLET 460HR 51 115 0.38 93 P 3 TWO 10 008

-0.71 008 008 WAR 4115 OUTLET 520SI 2.25 19 2

TEA UTE

-0.16 UTE UTE 2056 INLET 460HR 51 116 8.52 177 1 ONT LTE

+10.22 LTE LTE 4115 OUTLET 520SI 0.27 125 P 3 TWO 7 010

-0.72 010 010 WAR 4115 OUTLET 520SI 0.18 61 2

VOL 012

+1.07 012 012 4115 OUTLET 520SI 6.41 175 1 ONT UTE

-10.48 UTE UTE 4115 OUTLET 520S1 2.69 27 2

TEA UTE

-0.12 UTE UTE 2055 INLET 460HR 51 117 5.88 175 1 ONT LTE

+11. 65 LTE LTE 4114 OUTLET 520SI 7.03 164 1 ONT UTE

-10.85 UTE UTE 4114 OUTLET 520SI 51 124 6.77 169 1 ONT LTE

+11.50 LTE LTE 4114 OUTLET 520S1 0.66 64 P 3 TWO 12 008

-0.68 008 008 WAR 4114 OUTLET 520S1 10.16 175 1 ONT 010

-0.13 010 010 4130 INLET 460SI 7.80 166 1 ONT UTE

-10.40 UTE UTE 4124 OUTLET 520SI 2.53 30 2

TEA UTE

-0.19 UTE UTE 2056 INLET 460HR 52 1

7.33 345 1 ONT UTS

+12.76 UTE UTS 4071 INLET 460SI 12.10 168 1 ONT 010

+0.47 011 010 4071 INLET 460SI 0.34 133 2 VOL 001

+0.94 002 001 4071 INLET 460S1 7.72 340 1 ONT LTE

+11. 51 LTS LTE 4071 INLET 460SI 1.51 24 2

TEA UTE

-0.17 UTE UTE 2091 INLET

. 460HR 52 5

0.65 78 P 3 TWO 7 010

+0.65 010 010 WAR 4036 INLET 460SI 52 7

2.16 22 2

TEA UTE

-0.22 UTE UTE 2091 INLET 460HR 52 8

3.36 21 2

TEA UTE

-0.24 UTE UTE 2090 INLET 460HR 0.80 73 2

VOL 013

+0.77 013 013 4036 INLET 460SI 52 9

0.76 49 2

VOL 013

+1.19 013 013 4036 INLET 460SI 52 11 1.00 87 P 3 TWO 11 009

+0.71 009 009 WAR 4036 INLET 460SI 52 12 4.27 29 2

TEA UTE

-0.19 UTE UTE 2090 INLET 460HR 52 14 1.13 15 2

TEA UTE

-0.13 UTE UTE 2090 INLET 460HR 52 15

1. 78 35 2

TEA UTE

-0.19 UTE UTE 2091 INLET 460HR 52 16 5.64 172 1 ONT LTS

-8.71 LTS LTS 4036 INLET 460SI 52 17 3.75 32 2

TEA UTE

-0.21 UTE UTE 2091 INLET 460HR 0.29 90 2

VOL 011

+0.90 011 011 4036 INLET 460SI 0.47 72 P 3 TWO 6 008

+0.57 008 008 WAR 4036 INLET 460SI 52 19 2.68 30 2

TEA UTE

-0.22 UTE UTE 2091 INLET 460HR 52 21 3.00 27 2

TEA UTE

-0.20 UTE UTE 2091 INLET 460HR 52 22 2.66 23 2

TEA UTE

-0.23 UTE UTE 2090 INLET 460HR 52 23 2.92 27 2

TEA UTE

-0.13 UTE UTE 2091 INLET 460HR 52 27 2.22 21 2

TEA UTE

-0.13 UTE UTE 2090 INLET 460HR 52 44 5.85 25 2

TEA UTE

-0.15 UTE UTE 2091 INLET 460HR 52 47 3.25 26 2

TEA UTE

-0.15 UTE UTE 2090 INLET 460HR 52 58 2.80 26 2

TEA UTE

-0.14 UTE UTE 2099 INLET 460HR 52 59 6.43 27 2

TEA UTE

-0.08 UTE UTE 2098 INLET 460HR 52 60 2.65 17 2

TEA UTE

-0.10 UTE UTE 2098 INLET 460HR 52 64 8.59 22 2

TEA UTE

-0.10 UTE UTE 2074 INLET 460HR 52 66

1. 49 23 2

TEA UTE

-0.19 UTE UTE 2074 INLET 460HR 52 71 6.71 175 1 ONT 003

+12.84 003 003 4124 OUTLET 520SI 52 74 6.19 28 2

TEA UTE

-0.14 UTE UTE 2060 INLET 460HR 52 75 3.73 24 2

TEA UTE

-0.23 UTE UTE 2059 INLET 460HR 52 77 2.92 22 2

TEA UTE

-0.14 UTE UTE 2059 INLET 460HR 52 78 2.30 21 2

TEA UTE

-0.22 UTE UTE 2060 INLET 460HR 52 79 5.04 167 1 ONT LTE

+8.91 LTE LTE 4124 OUTLET 520SI 52 82 1.33 97 1

VOL 008

-13.22 008 008 4124 OUTLET 520S1 52 85 3.51 26 2

TEA UTE

-0.14 UTE UTE 2055 INLET 460HR 52 87 2.83 17 2

TEA UTE

-0.14 UTE UTE 2055 INLET 460HR 52 88 4.46 25 2

TEA UTE

-0.16 UTE UTE 2056 INLET 460HR 52 90 2.58 20 2

TEA UTE

-0.17 UTE UTE 2056 INLET 460HR 52 92 3.19 20 2

TEA UTE

-0.14 UTE UTE 2056 INLET 460HR 52 93 2.72 30 2

TEA UTE

-0.16 UTE UTE 2055 INLET 460HR 52 94 3.18 20 2

TEA UTE

-0.14 UTE UTE 2056 INLET 460HR 52 95 3.22 21 2

TEA UTE

-0.12 UTE UTE 2055 INLET 460HR 52 96 0.23 64 2

SAl 012

-8.83 012 012 4124 OUTLET 520SI 0.23 64 2

TWO 57 012

-8.83 012 012 4124 OUTLET 520SI 5.04 21 2

TEA UTE

-0.20 UTE UTE 2056 INLET 460HR 52 97 3.21 25 2

TEA UTE

-0.16 UTE UTE 2055 INLET 460HR 52 98 2.17 18 2

TEA UTE

-0.21 UTE UTE 2056 INLET 460HR 52 99 1.25 26 2

TEA UTE

-0.14 UTE UTE 2055 INLET 460HR 52 100 3.31 23 2

TEA UTE

-0.16 UTE UTE 2056 INLET 460HR 52 101 0.20 101 2 VOL 007

+0.77 007 007 4115 OUTLET 520SI 2.32 19 2

TEA UTE

-0.12 UTE UTE 2055 INLET 460HR 52 102 0.18 71 2

VOL 007

+1. 04 007 007 4115 OUTLET 520SI 2.37 23 2

TEA UTE

-0.21 UTE UTE 2056 INLET 460HR

Framatome ANP Inc.

customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION 52 52 52 52 52 52 52 52 52 52 52 52 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 103 104 105 106 109 113 116 119 120 121 123 125 1

6 9

11 12 14 15 17 19 22 24 36 39 43 45 46 55 56 58 60 65 67 69 71 72 82 86 87 90 92 93 94 95 97 0.22 0.19 3.09 5.65 7.63 2.68 7.06 7.47 2.13 6.40 5.60

1. 64 0.23 6.12 7.27 7.06
1. 34 0.44 3.86 2.57
1. 34 8.79 5.27 0.32 7.84 2.30 7.75 0.44 7.40 6.44 12.41 2.87 8.09 7.32 4.38 2.72 0.29 4.33 0.78 0.78 2.73 4.08 2.85 0.38 3.90 0.81 0.34 2.91 3.11 2.23 2.04 2.36 5.26 0.13 0.13 1.16 3.15 2.66
1. 61 1.37 6.73 4.14
1. 62 5.71 0.11 0.11
1. 97 2.05 3.95 3.05 3.68 5.22
1. 65 3.53
1. 61 VOL VOL TEA DNT DNT TEA DNT DNT TEA DNT DNT TEA VOL DNT DNT DNT TEA 3 TWD 10 TEA TEA TEA DNT DNT PLP DNT TEA DNT 3 TWD 11 DNT DNT DNT TEA DNT ONT TEA TEA PLP TEA SVI TWO 41 TEA TEA TEA 78 2

64 2

23 2

170 1 172 1 19 2

175 1 180 1 24 2

171 1 171 1 28 2

68 2

170 1 172 1 178 1 22 2

76 P

23 2

26 2

35 2

165 1 171 1 76 9

169 1 25 2

167 1 107 P 169 1 169 1 173 1 16 2

175 1 173 1 24 2

22 2

80 9

23 2

16 2

16 2

22 2

27 2

16 2

89 P 3 TWO 5 2

TEA 23 93 P

44 P

23 2

23 2

161 1 168 1 15 2

28 2

56 2

56 2

18 2

21 2

20 2

20 2

26 2

23 2

166 1 27 2

27 2

80 2

86 2

35 2

26 2

22 2

23 2

26 2

24 2

29 2

19 2

2 28 3 TWO 9 3 TWO 4 TEA TEA ONT DNT TEA TEA SAl TWO 87 TEA TEA TEA TEA TEA TEA ONT TEA TEA VOL VOL TEA TEA TEA TEA TEA TEA TEA TEA TEA 007 007 UTE LTE UTE UTE LTE UTE UTE LTE UTE UTE 009 LTE LTE UTE UTE 010 UTE UTE UTE LTE 010 014 UTE UTE LTE 007 UTE UTE 010 UTE UTS LTE UTE UTE 014 UTE UTE UTE UTE UTE UTE 010 UTE 008 008 UTE UTE UTS UTS UTE UTE 007 007 UTE UTE UTE UTE UTE UTE 006 UTE UTE 011 011 UTE UTE UTE UTE UTE UTE UTE UTE UTE

+0.85

+0.91

-0.14

+11. 02

-11. 66

-0.16

+11.40

-11. 71

-0.16

+11. 09

-11. 33

-0.20

-0.59

+11. 01

+10.39

-11. 40

-0.22

-0.76

-0.20

-0.18

-0.23

+10.40

-0.56

+1.17

-10.32

-0.16

+11.02

-0.74

-11.62

-11. 22

-0.19

-0.21

+11.77

+11. 43

-0.25

-0.20

+0.89

-0.24

-1. 29

-1. 29

-0.31

-0.25

-0.26

-0.76

-0.19

-0.79

+0.61

-0.29

-0.15

-16.30

-17.27

-0.32

-0.09

-14.96

-14.96

-0.14

-0.04

-0.19

-0.13

-0.20

-0.15

-9.57

-0.19

-0.13

+14.31

+11. 97

-0.20

-0.16

-0.17

-0.15

-0.13

-0.12

-0.17

-0.20

-0.17 05/02/02 13:29:24 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG 007 007 007 007 UTE UTE LTE LTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE 009 009 LTE LTE LTE LTE UTE UTE UTE UTE 010 010 WAR UTE UTE UTE UTE UTE UTE LTE LTE 010 010 014 014 UTE UTE UTE UTE LTE LTE 007 007 WAR UTE UTE UTE UTE 010 010 UTE UTE UTE UTS LTS LTE UTE UTE UTE UTE 014 014 UTE UTE UTE UTE TR UTE UTE UTE UTE UTE UTE UTE UTE 010 010 WAR UTE UTE 008 008 WAR 008 008 WAR UTE UTE UTE UTE UTS UTS UTS UTS UTE UTE UTE UTE 007 007 007 007 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 006 006 UTE UTE UTE UTE 011 011 011 011 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 4115 4115 2056 4115 4115 2055 4115 4115 2056 4115 4115 2.055 4115 4115 4115 4115 2056 4115 2055 2055 2056 4115 4115 4115 4115 2055 4115 4115 4115 4115 4130 2056 4071 4071 2091 2091 4036 2091 2091 2091 2090 2091 2090 4036 2090 4036 4036 2090 2090 4067 4067 2090 2090 4067 4067 2091 2090 2099 2099 2099 2108 4124 2059 2059 4124 4124 2060 2060 2059 2060 2060 2059 2060 2059 2059 OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 56 of 155 PROBE 520S1 520SI 460HR 520SI 520S1 460HR 520SI 520SI 460HR 520SI 520SI 460HR 520SI 520SI 520SI 520SI 460HR 520SI 460HR 460HR 460HR 520SI 520SI 520SI 520SI 460HR 520SI 520SI 520SI 520S1 460SI 460HR 460SI 460SI 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460SI 46051 460HR 460HR 460SI 460SI 460HR 460HR 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 520SI 460HR 460HR 520SI 520SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR

Framatome ANP Inc.

05/02/02 13:29:24 Customer Name: Oconee Unit 1 Component: S/G B Page 57 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

53 98

1. 31 38 2

TEA UTE

-0.21 UTE UTE 2060 INLET 460HR 53 99 2.76 33 2

TEA UTE

-0.21 UTE UTE 2059 INLET 460HR 53 100 3.43 25 2

TEA UTE

-0.15 UTE UTE 2060 INLET 460HR 53 102

1. 62 17 2

TEA UTE

-0.16 UTE UTE 2060 INLET 460HR 53 103 4.99 28 2

TEA UTE

-0.15 UTE UTE 2059 INLET 460HR 53 104 3.54 28 2

TEA UTE

-0.17 UTE UTE 2060 INLET 460HR 53 105 8.12 37 1

SAl UTE

-1. 63 UTE UTE 603 INLET 410MB 53 108 5.39 170 1 oNT LTE

+11. 64 LTE LTE 4116 OUTLET 520S1 2.42 37 2

TEA UTE

-0.18 UTE UTE 2059 INLET 460HR 53 109 6.46 173 1 oNT LTE

+11. 39 LTE LTE 4116 OUTLET 520S1 6.67 170 1 oNT UTE

-11. 65 UTE UTE 4116 OUTLET 520S1 1.25 23 2

TEA UTE

-0.20 UTE UTE 2060 INLET 460HR 53 111

1. 88 22 2

TEA UTE

-0.19 UTE UTE 2060 INLET 460HR 53 112 2.69 30 2

TEA UTE

-0.21 UTE UTE 2059 INLET 460HR 53 113 0.23 95 P 3 TWO 4 009

-0.55 009 009 WAR 4116 OUTLET 520S1 1.07 28 2

TEA UTE

-0.19 UTE UTE 2060 INLET 460HR 53 114 4.20 31 2

TEA UTE

-0.26 UTE UTE 2059 INLET 460HR 53 117 7.26 172 1 ONT UTE

-10.97 UTE UTE 4115 OUTLET 520SI 6.38 356 1 ONT LTE

+11. 05 LTE LTE 4130 INLET 460SI

1. 01 16 2

TEA UTE

-0.23 UTE UTE 2060 INLET 460HR 53 118 6.74 168 1 ONT UTE

-10.91 UTE UTE 4115 OUTLET 520S1 5.37 354 1 oNT LTE

+10.60 LTE LTE 4130 INLET 460S1 3.58 22 2

TEA UTE

-0.18 UTE UTE 2059 INLET 460HR 53 119 0.65 74 P 3 TWO 14 010

-0.75 010 010 WAR 4115 OUTLET 520S1 0.92 32 2

TEA UTE

-0.21 UTE UTE 2060 INLET 460HR 53 120 0.38 88 P 3 TWO 8 008

-0.72 008 008 WAR 4115 OUTLET 520S1 53 122 8.07 173 1 ONT 010

-0.56 010 010 4115 OUTLET 520S1 1.26 35 2

TEA UTE

-0.20 UTE UTE 2059 INLET 460HR 53 123 6.53 24 2

TEA UTE

-0.18 UTE UTE 2060 INLET 460HR 53 125 8.89 36 1

SCI LTE

+0.50 LTE LTE 718 OUTLET 380EX 12.59 25 1

SCI LTE

+2.22 LTE LTE 718 OUTLET 380EX 53 126 6.61 170 1 ONT LTE

+11.09 LTE LTE 4115 OUTLET 520SI 0.29 69 P 3 TWO 6 007

-0.. 79 007 007 WAR 4115 OUTLET 520SI 0.26 101 P 3 TWO 6 007

+0.59 007 007 WAR 4115 OUTLET 520SI 0.12 59 9

PLP 007

+0.90 007 007 4115 OUTLET 520S1 0.14 76 2

VOL 011

+0.83 011 011 4115 OUTLET 520S1 6.69 170 1 ONT UTE

-11.11 UTE UTE 4115 OUTLET 520S1 2.79 28 2

TEA UTE

-0.20 UTE UTE 2060 INLET 460HR 54 1

4.83 162 1 ONT UTS

+12.89 UTE UTS 4071 INLET 460SI

11. 06 165 1 oNT 010

+0.62 011 010 4071 INLET 460S1 10.52 169 1 ONT LTE

+11. 75 LTE LTS 4071 INLET 460SI 1.28 29 2

TEA UTE

-0.21 UTE UTE 2091 INLET 460HR 54 6

0.63 58 P 3 TWO 6 009

-0.17 009 009 WAR 4036 INLET 460S1 54 8

0.24 0

P 3 TWO 4 008

+0.67 008 008 WAR 4036 INLET 460SI 54 9

4.41 23 2

TEA UTE

-0.17 UTE UTE 2090 INLET 460HR 54 11 3.36 30 2

TEA UTE

-0.23 UTE UTE 2090 INLET 460HR 0.48 100 P 3 TWO 5 009

+0.66 009 009 WAR 4036 INLET 460SI 54 13 0.48 83 P 3 TWO 6 008

+0.60 008 008 WAR 4036 INLET 460SI 54 14 0.19 79 2

VOL 014

+1.14 014 014 4036 INLET 460SI 54 15

1. 89 29 2

TEA UTE

-0.22 UTE UTE 2090 INLET 460HR 54 17 4.99 171 1 ONT LTE

+13.31 LTE LTE 4036 INLET 460S1 54 19 6.07 29 2

TEA UTE

-0.18 UTE UTE 2091 INLET 460HR 0.56 58 P 3 TWO 6 008

+0.59 008 008 WAR 4036 INLET 460SI 54 20 2.89 23 2

TEA UTE

-0.13 UTE UTE 2090 INLET 460HR 54 23 3.54 22 2

TEA UTE

-0.17 UTE UTE 2091 INLET 460HR 54 26 2.25 23 2

TEA UTE

-0.14 UTE UTE 2090 INLET 460HR 54 40 3.32 19 2

TEA UTE

-0.17 UTE UTE 2090 INLET 460HR 54 47

1. 94 171 1 ONT UTS

+3.50 UTS UTS 4067 INLET 460SI 54 48 6.26 26 2

TEA UTE

-0.10 UTE UTE 2090 INLET 460HR 54 49 6.07 26 2

TEA UTE

-0.10 UTE UTE 2091 INLET 460HR 54 52 0.42 96 2

VOL 001

+6.02 001 001 4067 INLET 460SI 54 63 10.12 350 1 ONT 004

-18.45 004 004 4130 INLET 460SI 54 72 0.91 165 P 3 TWO 0 UTE

-0.49 TO+341. 8 UTE UTS 2060 INLET 460HR 1.02 19 P 3 TWO 46 UTE

-0.49 TO+332.7 UTE UTS 2060 INLET 460HR 2.83 34 P 3 TWO 76 UTE

-0.49 TO+323.5 UTE UTS 2060 INLET 460HR 4.18 36 P 3 TWO 93 UTE

-0.49 TO+314.4 UTE UTS 2060 INLET 460HR 2.82 32 P 3 TWO 76 UTE

-0.49 TO+305.3 UTE UTS 2060 INLET 460HR 0.63 160 P 3 TWO 36 UTE

-0.49 TO+296.2 UTE UTS 2060 INLET 460HR 0.47 120 P 3 TWO 0 UTE

-0.49 TO+287.1 UTE UTS 2060 INLET 460HR 5.42 38 P 1 SCI UTE

-0.49 UTE UTS CL/CS 2060 INLET 460HR 0.88 27 P 1 SCI UTE

-3.67 UTE UTS TR 2060 INLET 460HR 0.18 162 P 3 TWO 43 UTE

-3.67 TO+182.3 UTE UTS 2060 INLET 460HR 0.15 159 P 3 TWO 0 UTE

-3.67 TO+191. 4 UTE UTS 2060 INLET 460HR 0.22 20 P 3 TWO 47 UTE

-3.67 TO+173.2 UTE UTS 2060 INLET 460HR 0.30 26 P 3 TWO 56 UTE

-3.67 TO+164.1 UTE UTS 2060 INLET 460HR

Framatome ANP Inc.

05/02/02 13:29:25 Customer Name: Oconee Unit 1 Component: S/G B Page 58 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS - MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

0.34 23 P 3 TWO 59 UTE

-3.67 TO+154.9 UTE UTS 2060 INLET 460HR 0.37 21 P 3 TWO 62 UTE

-3.67 TO+145.8 UTE UTS 2060 INLET 460HR 0.51 24 P 3 TWO 73 UTE

-3.67 TO+136.7 UTE UTS 2060 INLET 460HR 0.56 23 P 3 TWO 76 UTE

-3.67 TO+127.6 UTE UTS 2060 INLET 460HR 0.53 22 P 3 TWO 74 UTE

-3.67 TO+118.5 UTE UTS 2060 INLET 460HR 0.63 24 P 3 TWO 80 UTE

-3.67 TO+109.4 UTE UTS 2060 INLET 460HR 0.69 24 P 3 TWO 84 UTE

-3.67 TO+100.3 UTE UTS 2060 INLET 460HR 0.70 21 P 3 TWO 85 UTE

-3.67 TO+91.1 UTE UTS 2060 INLET 460HR 0.64 21 P 3 TWO 81 UTE

-3.67 To+82.0 UTE UTS 2060 INLET 460HR 0.66 20 P 3 TWO 83 UTE

-3.67 TO+72.9 UTE UTS 2060 INLET 460HR 0.62 17 P 3 TWO 80 UTE

-3.67 TO+63.8 UTE UTS 2060 INLET 460HR 0.50 17 P 3 TWO 72 UTE

-3.67 TO+54.7 UTE UTS 2060 INLET 460HR 0.45 16 P 3 TWO 68 UTE

-3.67 TO+45.6 UTE UTS 2060 INLET 460HR 0.40 20 P 3 TWO 65 UTE

-3.67 TO+36.5 UTE UTS 2060 INLET 460HR 0.33 19 P 3 TWO 58 UTE

-3.67 TO+27.3 UTE UTS 2060 INLET 460HR 0.19 21 P 3 TWO 0 UTE

-3.67 TO+18.2 UTE UTS 2060 INLET 460HR 54 73 1.24 25 2

TEA UTE

-0.20 UTE UTE 2059 INLET 460HR 54 75 0.53 11 2

VOL UTE

-0.79 UTE UTE 2055 INLET 460HR 54 78 1.27 36 2

TEA UTE

-0.28 UTE UTE 2059 INLET 460HR 54 79 7.40 33 2

TEA UTE

-0.17 UTE UTE 2060 INLET 460HR 54 85 3.40 19 2

TEA UTE

-0.12 UTE UTE 2059 INLET 460HR 54 86 1.75 27 2

TEA UTE

-0.21 UTE UTE 2059 INLET 460HR 54 93

1. 85 34 2

TEA UTE

-0.20 UTE UTE 2059 INLET 460HR 54 94 2.80 21 2

TEA UTE

-0.21 UTE UTE 2060 INLET 460HR 54 95 2.00 30 2

TEA UTE

-0.18 UTE UTE 2059 INLET 460HR 54 96 2.24 26 2

TEA UTE

-0.14 UTE UTE 2060 INLET 460HR 54 97 2.56 33 2

TEA UTE

-0.17 UTE UTE 2059 INLET 460HR 54 98 5.01 25 2

TEA UTE

-0.13 UTE UTE 2060 INLET 460HR 54 100 0.35 113 P 3 TWO 0 UTE

-0.42 TO+198.0 UTE UTS 2060 INLET 460HR 0.43 121 P 3 TWO 56 UTE

-0.42 TO+189.0 UTE UTS 2060 INLET 460HR 0.90 37 P 3 TWO 81 UTE

-0.42 TO+180.0 UTE UTS 2060 INLET 460HR 1.32 30 P 3 TWO 98 UTE

-0.42 TO+171.0 UTE UTS 2060 INLET 460HR 0.44 102 P 3 TWO 56 UTE

-0.42 TO+162.0 UTE UTS 2060 INLET 460HR 0.47 326 P 3 TWO 0 UTE

-0.42 TO+153.0 UTE UTS 2060 INLET 460HR 1.87 25 P 1 SCI UTE

-0.42 UTE UTS CL 2060 INLET 460HR 54 102 0.94 23 2

TEA UTE

-0.24 UTE UTE 2060 INLET 460HR 54 106. 0.87 26 2

TEA UTE

-0.22 UTE UTE 2060 INLET 460HR 54 108 3.08 30 2

TEA UTE

-0.22 UTE UTE 2059 INLET 460HR 54 109 5.27 27 2

TEA UTE

-0.18 UTE UTE 2059 INLET 460HR 54 111

1. 97 24 2

TEA UTE

-0.23 UTE UTE 2060 INLET 460HR 54 112 0.39 82 P 3 TWO 7 009

-0.63 009 009 WAR 4116 OUTLET 520SI 54 113 0.37 59 P 3 TWO 6 009

-0.64 009 009 WAR 4116 OUTLET 520SI 54 116 0.35 106 P 3 TWO 6 009

+0.33 009 009 WAR 4116 OUTLET 520SI 54 121 4.63 174 1 ONT 010

-0.62 010 010 4116 OUTLET 520SI 54 122 5.23 168 1 ONT 010

-0.62 010 010 4116 OUTLET 520SI 4.02 28 2

TEA UTE

-0.16 UTE UTE 2059 INLET 460HR 54 123 1.18 29 2

TEA UTE

-0.21 UTE UTE 2059 INLET 460HR 54 124 6.66 165 1 ONT LTE

+11.94 LTE LTE 4116 OUTLET 520SI 4.02 171 1 ONT 010

-0.53 010 010 4116 OUTLET 520SI 7.07 170 1 ONT UTE

-11. 44 UTE UTE 4116 OUTLET 520SI 1.38 28 2

TEA UTE

-0.17 UTE UTE 2060 INLET 460HR 54 125 5.99 346 1 DNT LTE

+9.82 LTE LTE 4116 OUTLET 520SI 6.44 169 1 ONT LTE

+10.92 LTE LTE 4116 OUTLET 520SI 0.11 97 2

VOL 012

+1.00 012 012 4116 OUTLET 520SI 0.15 78 2

VOL 013

+1. 48 013 013 4116 OUTLET 520SI 5.49 347 1 ONT UTE

-11.24 UTE UTE 4116 OUTLET 520SI 2.72 35 2

TEA UTE

-0.18 UTE UTE 2059 INLET 460HR 54 126 4.85 168 1 ONT LTE

+10.52 LTE LTE 4116 OUTLET 520SI 0.2B BB 2

VOL 012

+1. 02 012 012 4116 OUTLET 520SI 5.64 170 1 ONT UTE

-11. 22 UTE UTE 4116 OUTLET 520SI 3.23 20 2

TEA UTE

-0.21 UTE UTE 2060 INLET 460HR 54 127 3.75 20 2

TEA UTE

-0.14 UTE UTE 2060 INLET 460HR 55 1

7.B3 171 1 DNT UTE

-12.82 UTE UTE 4036 INLET 460SI 0.93 98 P 3 TWO 10 011

-0.69 011 011 WAR 4036 INLET 460SI 0.B2 93 P 3 TWD 9 008

+0.67 008 008 WAR 4036 INLET 460SI 6.61 163 1 ONT LTE

+10.89 LTE LTE 4036 INLET 460SI 55 8

1.92 22 2

TEA UTE

-0.17 UTE UTE 2091 INLET 460HR 55 9

3.16 25 2

TEA UTE

-0.15 UTE UTE 2090 INLET 460HR 55 12 3.24 24 2

TEA UTE

-0.24 UTE UTE 2091 INLET 460HR 55 14 2.98 28 2

TEA UTE

-0.19 UTE UTE 2091 INLET 460HR 55 15 2.38 23 2

TEA UTE

-0.24 UTE UTE 2090 INLET 460HR 55 16 0.42 75 P 3 TWO 5 008

+0.73 008 008 WAR 4036 INLET 460SI 55 17 3.25 27 2

TEA UTE

-0.22 UTE UTE 2090 INLET 460HR 55 18 0.32 122 P 3 TWO 5 008

+0.58 008 008 WAR 4036 INLET 460SI 55 21 1.88 21 2

TEA UTE

-0.20 UTE UTE 2090 INLET 460HR

Framatome ANP Inc.

05/02/02 13:29:26 Customer Name: Oconee Unit 1 Component: S/G B Page 59 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

55 40

1. 54 17 2

TEA UTE

-0.04 UTE UTE 2087 INLET 460HR 55 41

1. 64 15 2

TEA UTE

-0.23 UTE UTE 2086 INLET 460HR 55 45

1. 66 15 2

TEA UTE

-0.13 UTE UTE 2086 INLET 460HR 55 52 0.13 90 2

VOL UTE

-3.95 UTE UTS 2087 INLET 460HR 55 56 5.12 177 1 ONT LTS

+8.65 LTS 001 4125 OUTLET 520SI 55 67 4.78 23 2

TEA UTE

-0.19 UTE UTS 2074 INLET 460HR 55 68 1.02 22 2

TEA UTE

-0.18 UTE UTE 2073 INLET 460HR 55 77

1. 02 165 1 ONT UTS

+4.36 UTS UTS 4124 OUTLET 520S1 1.29 158 1 ONT UTS

+4.48 UTS UTS 4124 OUTLET 520SI 0.94 144 1 ONT UTS

+5.03 UTS UTS 4124 OUTLET 520S1 1.23 28 2

TEA UTE

-0.18 UTE UTE 2059 INLET 460HR 55 82

1. 62 21 2

SAl UTE

-3.58 UTE UTS 2060 INLET 460HR

1. 62 21 2

TWO 60 UTE

-3.58 UTE UTS 2060 INLET 460HR 55 83 2.93 29 2

TEA UTE

-0.19 UTE UTE 2059 INLET 460HR 55 84 2.34 16 2

TEA UTE

-0.13 UTE UTE 2060 INLET 460HR 55 85 3.33 29 2

TEA UTE

-0.18 UTE UTE 2059 INLET 460HR 55 86 4.00 26 2

TEA UTE

-0.19 UTE UTE 2060 INLET 460HR 55 91 3.21 30 2

TEA UTE

-0.22 UTE UTE 2059 INLET 460HR 55 92 4.16 17 2

TEA UTE

-0.16 UTE UTE 2060 INLET 460HR 55 93 2.08 24 2

TEA UTE

-0.14 UTE UTE 2059 INLET 460HR 55 94 2.74 27 2

TEA UTE

-0.19 UTE UTE 2060 INLET 460HR 55 96

1. 93 23 2

TEA UTE

-0.18 UTE UTE 2060 INLET 460HR 55 97

1. 34 29 2

TEA UTE

-0.18 UTE UTE 2059 INLET 460HR 55 103 1.58 25 2

TEA UTE

-0.20 UTE UTE 2059 INLET 460HR 55 104 1.48 22 2

TEA UTE

-0.18 UTE UTE 2060 INLET 460HR 55 106 3.01 27 2

TEA UTE

-0.16 UTE UTE 2060 INLET 460HR 55 107 0.51 115 P 3 TWO 12 008

-0.37 008 008 WAR 4117 OUTLET 520SI 2.77 25 2

TEA UTE

-0.15 UTE UTE 2059 INLET 460HR 55 112 0.27 119 P 3 TWO 7 009

-0.70 009 009 WAR 4117 OUTLET 520SI 0.25 88 P 3 TWO 6 009

-0.71 009 009 WAR 4117 OUTLET 520SI 55 114 0.37 84 2

VOL 014

+1.02 014 014 4117 OUTLET 520SI 55 117 0.45 76 2

SVI 014

+1. 68 014 014 4117 OUTLET 520SI 0.45 75 P 4 TWO 32 014

+1.65 014 014 4117 OUTLET 520SI 55 118 0.61 86 P 3 TWO 14 010

-0.66 010 010 WAR 4117 OUTLET 520SI 0.19 33 P 3 TWO 5 014

+0.74 014 014 WAR 4117 OUTLET 520SI 55 119 0.36 100 P 3 TWO 9 010

-0.77 010 010 WAR 4117 OUTLET 520S1 2.55 17 2

TEA UTE

-0.15 UTE UTE 2059 INLET 460HR 55 120 0.60 124 P 3 TWD 14 010

-0.73 010 010 WAR 4117 OUTLET 520S1 55 121 0.32 108 P 3 TWO 8 008

-0.80 008 008 WAR 4117 OUTLET 520S1 3.87 191 P 3 ONT 010

-0.49 010 010 4117 OUTLET 520SI 55 122 7.91 174 1 ONT 010

-0.53 010 010 4117 OUTLET 520SI 55 123 4.48 185 1 ONT LTE

+11. 55 LTE LTE 4117 OUTLET 520SI 5.34 192 P 3 ONT 010

-0.61 010 010 4117 OUTLET 520SI 5.70 183 1 ONT UTS

+12.53 UTS UTE 4117 OUTLET 520SI 3.63 21 2

TEA UTE

-0.20 UTE UTE 2059 INLET 460HR 55 126 6.47 183 1 DNT LTE

+9.88 LTE LTE 4117 OUTLET 520S1 3.87 182 1 ONT LTE

+11. 21 LTE LTE 4117 OUTLET 520SI 3.45 189 1 ONT UTE

-11. 30 UTE UTE 4117 OUTLET 520SI 4.85 190 1 ONT UTE

-11. 90 UTE UTE 4117 OUTLET 520SI 56 1

4.87 26 2

TEA UTE

-0.12 UTE UTE 2087 INLET 460HR 56 3

2.26 23 2

TEA UTE

-0.07 UTE UTE 2087 INLET 460HR 56 5

3.19 22 2

TEA UTE

-0.06 UTE UTE 2087 INLET 460HR 56 6

4.45 23 2

TEA UTE

-0.16 UTE UTE 2086 INLET 460HR 0.61 112 P 3 TWO 9 008

+0.52 008 008 WAR 4027 INLET 460SI 56 7

0.35 108 P 3 TWO 4 008

+0.67 008 008 WAR 4036 INLET 460SI 56 8

1. 62 17 2

TEA UTE

-0.17 UTE UTE 2086 INLET 460HR 0.20 69 2

VOL 011

+1. 04 011 011 4036 INLET 460SI 56 9

2.28 22 2

TEA UTE

-0.11 UTE UTE 2087 INLET 460HR 56 10 4.51 23 2

TEA UTE

-0.21 UTE UTE 2086 INLET 460HR 0.46 63 P 3 TWD 5 008

+0.68 008 008 WAR 4036 INLET 460S1 56 12 3.84 21 2

TEA UTE

-0.14 UTE UTE 2086 INLET 460HR 56 17 4.28 165 1 ONT LTS

-6.68 LTS LTS 4036 INLET 460SI 56 26

1. 39 69 2

TEA UTE

-0.15 UTE UTE 2086 INLET 460HR 56 28 2.05 18 2

TEA UTE

-0.11 UTE UTE 2086 INLET 460HR 56 30 3.07 25 2

TEA UTE

-0.15 UTE UTE 2086 INLET 460HR 56 32 2.42 19 2

TEA UTE

-0.21 UTE UTE 2086 INLET 460HR 56 35 2.93 25 2

TEA UTE

-0.08 UTE UTE 2087 INLET 460HR 56 46 4.30 23 2

TEA UTE

-0.14 UTE UTE 2086 INLET 460HR 56 54 1.53 26 2

TEA UTE

-0.08 UTE UTE 2099 INLET 460HR 56 56 0.29 28 2

SVI UTE

-1.50 UTE UTE CS 2099 INLET 460HR 0.29 28 2

TWO 79 UTE

-1. 50 UTE UTE 2099 INLET 460HR 56 58 4.40 25 2

TEA UTE

-0.16 UTE UTE 2099 INLET 460HR 56 60

1. 62 25 2

TEA UTE

-0.15 UTE UTE 2099 INLET 460HR S6 69 8.26 21 2

TEA UTE

-0.17 UTE UTE 2074 INLET 460HR 56 71

1. 69 26 2

TEA UTE

-0.12 UTE UTE 2073 INLET 460HR

Framatome ANP Inc.

05/02/02 13:29:26 Customer Name: Oconee Unit 1 Component: S/G B Page 60 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -: MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

56 74 4.50 176 1 DNT LTE

+6.49 LTE LTE 4124 OUTLET 520SI 56 75 4.09 23 2

TEA UTE

-0.18 UTE UTE 2060 INLET 460HR 56 76 3.68 36 2

TEA UTE

-0.14 UTE UTE 2059 INLET 460HR 56 78

1. 91 32 2

TEA UTE

-0.22 UTE UTE 2059 INLET 460HR 56 81 2.07 18 2

TEA UTE

-0.12 UTE UTE 2060 INLET 460HR 56 83 3.59 26 2

TEA UTE

-0.17 UTE UTE 2060 INLET 460HR 56 85 3.83 28 2

TEA UTE

-0.32 UTE UTE 2059 INLET 460HR 56 90 2.67 23 2

TEA UTE

-0.27 UTE UTE 2059 INLET 460HR 56 91 2.21 172 1 DNT 010

-3.28 010 010 4124 OUTLET 520S1 56 93 4.17 30 2

TEA UTE

-0.20 UTE UTE 2060 INLET 460HR 56 95 2.11 22 2

TEA UTE

-0.17 UTE UTE 2060 INLET 460HR 56 100 4.60 32 2

TEA UTE

-0.18 UTE UTE 2059 INLET 4601lR 56 102 4.59 27 2

TEA UTE

-0.18 UTE UTE 2059 INLET 460HR 56 104 2.02 32 2

TEA UTE

-0.15 UTE UTE 2059 INLET 460HR 56 108

1. 93 24 2

TEA UTE

-0.17 UTE UTE 2059 INLET 460HR 56 110 4.21 34 2

TEA UTE

-0.15 UTE UTE 2059 INLET 460HR 56 112 2.45 25 2

TEA UTE

-0.13 UTE UTE 2059 INLET 460HR 56 113 0.35 50 P 3 TWD 9 009

-0.56 009 009 WAR 4117 OUTLET 520SI 2.92 28 2

TEA UTE

-0.13 UTE UTE 2060 INLET 460HR 56 115 5.15 31 2

TEA UTE

-0.18 UTE UTE 2060 INLET 460HR 56 117 0.23 83 2

VOL 011

+0.99 011 011 4117 OUTLET 520S1 1.05 24 2

TEA UTE

-0.15 UTE UTE 2059 INLET 460HR 56 118

1. 65 27 2

TEA UTE

-0.12 UTE UTE 2059 INLET 460HR 56 120 0.53 0

P 3 TWD 13 010

-0.79 010 010 WAR 4117 OUTLET 520S1 2.71 30 2

TEA UTE

-0.13 UTE UTE 2059 INLET 460HR 56 121 4.29 35 2

TEA UTE

-0.12 UTE UTE 2059 INLET 460HR 56 122 5.08 183 1 DNT 010

-0.62 010 010 4117 OUTLET 520SI 56 123 0.31 69 2

VOL 014

+0.96 014 014 4117 OUTLET 520SI 4.91 28 2

TEA UTE

-0.18 UTE UTE 2060 INLET 460HR 56 125 5.04 176 1 DNT LTE

+11. 03 LTE LTE 4117 OUTLET 520S1 0.11 58 2

VOL 006

+7.43 006 006 4117 OUTLET 520SI 0.14 72 2

VOL 006

+11. 64 006 006 4117 OUTLET 520S1 0.18 61 2

VOL 006

+6.87 006 006 4117 OUTLET 520SI 10.01 175 1 DNT 010

-0.64 010 010 4117 OUTLET 520SI 4.44 359 1 DNT UTE

-11.42 UTE UTE 4117 OUTLET 520S1 5.61 26 2

TEA UTE

-0.18 UTE UTE 2059 INLET 460HR 56 126 14.13 18 1

SCI LTE

+2.03 LTE LTE 724 OUTLET 380EX 57 1

1. 64 24 2

TEA UTE

-0.12 UTE UTE 2087 INLET 460HR 57 2

5.31 166 1 DNT LTE

+12.23 LTE LTE 4108 OUTLET 520S1 5.76 28 2

TEA UTE

-0.10 UTE UTE 2087 INLET 460HR 5.41 165 1 DNT UTE

-11.71 UTE UTE 4027 INLET 460S1 0.41 38 P 3 TWD 7 010

-0.62 010 010 WAR 4027 INLET 460S1 57 6

2.89 22 2

TEA UTE

-0.17 UTE UTE 2086 INLET 460HR 57 7

1. 36 42 2

TEA UTE

-0.07 UTE UTE 2087 INLET 460HR 0.27 74 P 4 TWD 6 008

+0.64 008 008 WAR 4027 INLET 460S1 57 8

0.17 40 P 3 TWD 3 011

+0.76 011 011 WAR 4027 INLET 460SI 57 11 2.12 23 2

TEA UTE

-0.11 UTE UTE 2087 INLET 460HR 57 13 0.54 88 P 3 TWD 6 008

+0.68 008 008 WAR 4036 INLET 460S1 57 16 0.70 130 P 3 TWD 8 008

-0.64 008 008 WAR 4036 INLET 460S1 57 17 0.49 114 P 3 TWD 5 008

+0.66 008 008 WAR 4036 INLET 460SI 57 23 0.18 103 2 VOL UTE

-4.63 UTE UTS 2137 INLET 460NR 0.60 22 2

VOL UTE

-0.60 UTE UTE 2087 INLET 460HR 57 28 3.71 155 1 DNT 005

-1.10 005 005 4036 INLET 460SI 57 29 0.11 110 2 VOL UTE

-3.68 UTE UTS 2087 INLET 460HR 57 32 0.08 50 2

VOL 007

-14.49 007 007 4067 INLET 460S1 2.29 21 2

TEA UTE

-0.20 UTE UTE 2086 INLET 460HR 57 45 2.26 25 2

TEA UTE

-0.11 UTE UTE 2087 INLET 460HR 57 47 2.51 25 2

TEA UTE

-0.05 UTE UTE 2087 INLET 460HR 57 61 2.89 24 2

TEA UTE

-0.14 UTE UTE 2099 INLET 460HR 57 63 2.17 24 2

SAl UTE

-3.62 UTE UTS 2099 INLET 460HR 2.17 24 2

TWD 66 UTE

-3.62 UTE UTS 2099 INLET 460HR 57 66

1. 81 23 2

TEA UTE

-0.09 UTE UTE 2108 INLET 460HR 57 68 1.59 19 2

TEA UTE

-0.17 UTE UTE 2073 INLET 460HR 57 69 3.74 25 2

TEA UTE

-0.13 UTE UTE 2074 INLET 460HR 57 70 3.56 25 2

TEA UTE

-0.13 UTE UTE 2073 INLET 460HR 57 71 4.04 30 2

TEA UTE

-0.16 UTE UTE 2108 INLET 460HR 57 72 4.27 26 2

TEA UTE

-0.14 UTE UTE 2073 INLET 460HR 57 73 3.00 33 2

TEA UTE

-0.10 UTE UTE 2104 INLET 460HR 57 74 3.53 28 2

TEA UTE

-0.22 UTE UTE 2073 INLET 460HR 57 75 4.59 31 2

TEA UTE

-0.24 UTE UTE 2059 INLET 460HR 57 76 5.10 25 2

TEA UTE

-0.18 UTE UTE 2060 INLET 460HR 57 77 2.24 33 2

TEA UTE

-0.21 UTE UTE 2059 INLET 460HR 57 78 3.10 20 2

TEA UTE

-0.16 UTE UTE 2060 INLET 460HR 57 83

1. 86 30 2

TEA UTE

-0.23 UTE UTE 2059 INLET 460HR 57 87 4.13 30 2

TEA UTE

-0.32 UTE UTE 2059 INLET 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -. MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 58 58 58 58 58 58 58 58 58 58 58 58 58 58 88 89 90 91 93 94 95 96 97 102 105 107 108 111 112 115 118 119 120 121 122 123 124 125 127 2

4 5

6 7

8 9

10 12 14 18 27 43 52 7.83 0.62 0.62 3.42 4.32 4.96 3.49 1.19 3.56 6.54 4.16 2.60 1.22 4.81 2.52 3.83 3.03 0.26 2.12 0.21 0.19 3.82 0.66 4.93 0.77 3.14 0.30 0.22 2.10

1. 87 10.28 3.02 9.33 0.24 4.55 0.09 0.16 3.10 6.86 0.24 0.11 0.46 5.66 2.75 2.41 3.33 0.22 8.12 4.33 9.67 6.44 0.15 0.23 0.22 2.38 0.97 2.81 2.18 2.14 2.44 3.41 0.59 1.34 3.28 0.70 0.00 0.32 0.46 0.36 0.28 0.24 0.00 2.70 6.60 0.00 23 25 25 25 26 27 24 14 26 26 32 22 47 27 25 26 28 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

TEA MAl TWD 74 TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA TEA 3 TWD 6 TEA PLP VOL TEA 76 P

27 2

69 9

297 2 29 2

94 P 3 TWO 16 2

TEA 28 85 P 3 TWO 18 2

TEA 28 100 P 73 9

31 2

23 2

170 1 31 2

168 1 266 9 29 2

90 2

81 9

35 2

177 1 o

P 104 2 260 9 175 1 36 2

23 2

348 1 30 2

355 1 357 1 176 1 353 1 84 2

91 2

95 2

23 2

18 2

17 2

27 2

14 2

32 2

25 2

3 TWO 7 PLP TEA TEA ONT TEA DNT PLP TEA VOL PLP TEA DNT 3 TWO 6 VOL PLP DNT TEA TEA ONT VOL DNT DNT DNT DNT VOL VOL VOL TEA TEA TEA TEA TEA TEA TEA 70 P 3 TWO 6 21 2

TEA 178 1 ONT 28 P 1 SCI o

P 3 TWO 0 24 P 3 TWO 34 22 P 3 TWO 67 26 P 3 TWO 43 19 P 3 TWO 27 13 P 3 TWO 20 o

P 3 TWO 0 24 2

TEA 19 P 1 SCI o

P 3 TWO 0 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 008 UTE 014 014 UTE 010 UTE 010 UTE 010 014 UTE UTE 010 UTE 010 014 UTE 014 014 UTE LTE 012 014 014 UTE UTE UTE UTE 013 LTE LTE LTE UTE 014 014 007 UTE UTE UTE UTE UTE UTE UTE 008 UTE LTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE

-0.15

-2.12

-2.12

-0.31

-0.18

-0.31

-0.28

-0.16

-0.31

-0.16

-0.18

-0.22

-0.25

-0.14

-0.19

-0.17

-0.16

-0.73

-0.18

+1. 21

+0.86

-0.15

-0.68

-0.09

-0.75

-0.22

-0.74

+1. 09

-0.21

-0.18

-0.52

-0.23

-0.51

+1. 35

-0.18

+2.09

+1.14

-0.17

+11.78

+0.72

+1. 42.

+1. 33

-11.40

-0.20

-0.11

-11. 94

+0.99

+11.06

+12.27

+11. 50

-11. 56

+1. 47

+0.84

+1.29

-0.20

-0.08

-0.19

-0.12

-0.22

-0.15

-0.15

+0.70

-0.14

-9.24

-3.77

-3.77

-3.77

-3.77

-3.77

-3.77

-3.77

-3.77

-0.17

-0.24

-0.24 TO+ll1.1 TO+120.0 TO+128.9 TO+137.8 TO+146.7 TO+155.6 TO+164.4 TO+140.5 05/02/02 13:29:27 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 008 008 UTE UTE 014 014 014 014 UTE UTE 010 010 UTE UTE 010 010 UTE UTE 010 010 014 014 UTE UTE UTE UTE 010 010 UTE UTE 010 010 014 014 UTE UTE 014 014 014 014 UTE UTE LTE LTE 012 012 014 014 014 014 UTE UTE UTE UTE UTE UTE UTE UTE 013 013 LTS LTE LTS LTE LTE LTE UTE UTE 014 014 014 014 007 007 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 008 008 UTE UTE LTS LT8 UTE UT8 UTE UT8 UTE UTS UTE UT8 UTE UTS UTE UT8 UTE UTS UTE UT8 UTE UTE UTE UTS UTE UTS WAR WAR WAR WAR WAR WAR CL/CS 2060 2060 2060 2059 2060 2059 2059 2060 2059 2060 2059 2060 2059 2059 2060 2059 2060 4117 2059 4117 4117 2060 4117 2059 4117 2060 4117 4117 2059 2060 4117 2059 4117 4117 2104 4117 4117 2059 4117 4117 4117 4117 4117 2059 2087 4027 4027 4027 4027 4108 4027 4027 4027 4027 2086 2087 2086 2087 2086 2087 2087 4036 2087 4036 2086 2086 2086 2086 2086 2086 2086 2086 2086 2087 2087 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET OUTLET OUTLET INLET OUTLET INLET OUTLET INLET OUTLET OUTLET INLET INLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 61 of 155 PROBE 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 520SI 460HR 520S1 520SI 460HR 52081 460HR 520SI 460HR 52081 520SI 460HR 460HR 520SI 460HR 520SI 520SI 460HR 52081 520SI 460HR 520SI 520SI 52081 520SI 520SI 460HR 460HR 46081 460SI 460SI 46081 520SI 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR

Framatome ANP Inc.

05/02/02 13:29:27 Customer Name: Oconee Unit 1 Component: S/G B Page 62 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS - MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

0.99 11 P 3 TWD 18 UTE

-0.24 TO+149.3 UTE UTS 2087 INLET 460HR 4.31 22 P 3 TWD 64 UTE

-0.24 TO+158.0 UTE UTS 2087 INLET 460HR 4.83 21 P 3 TWD 70 UTE

-0.24 TO+166.8 UTE UTS 2087 INLET 460HR

1. 41 18 P 3 TWD 24 UTE

-0.24 TO+175.6 UTE UTS 2087 INLET 460HR 0.73 177 P 3 TWD 14 UTE

-0.24 TO+184.4 UTE UTS 2087 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.24 TO+193.2 UTE UTS 2087 INLET 460HR 58 53 2.77 24 2

TEA UTE

-0.19 UTE UTE 2086 INLET 460HR 58 63 7.07 29 2

TEA UTE

-0.13 UTE UTE 2098 INLET 460HR 58 64 5.66 22 2

TEA UTE

-0.09 UTE UTE 2098 INLET 460HR 58 68 2.17 27 2

TEA UTE

-0.16 UTE UTE 2073 INLET 460HR 58 69 4.02 23 2

TEA UTE

-0.19 UTE UTE 2108 INLET 460HR 58 71 3.69 25 2

TEA UTE

-0.16 UTE UTE 2108 INLET 460HR 58 73 3.34 21 2

TEA UTE

-0.14 UTE UTE 2108 INLET 460HR 58 75 4.48 27 2

TEA UTE

-0.20 UTE UTE 2108 INLET 460HR 58 76 2.60 25 2

TEA UTE

-0.16 UTE UTE 2059 INLET 460HR 58 78 2.51 26 2

TEA UTE

-0.17 UTE UTE 2059 INLET 460HR 58 79

1. 48 22 2

MAl UTE

-3.26 UTE UTS 2060 INLET 460HR 1.48 22 2

TWD 63 UTE

-3.26 UTE UTS 2060 INLET 460HR 58 81 1.22 30 P 1 SCI UTE

-0.59 UTE UTS CL/CS 2059 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.59 TO+92.2 UTE UTS 2059 INLET 460HR 1.23 17 P 3 TWD 46 UTE

-0.59 TO+101.0 UTE UTS 2059 INLET 460HR 1.40 19 P 3 TWD 52 UTE

-0.59 TO+109.8 UTE UTS 2059 INLET 460HR 1.32 21 P 3 TWD 49 UTE

-0.59 TO+118.5 UTE UTS 2059 INLET 460HR 1.10 21 P 3 TWD 41 UTE

-0.59 TO+127.3 UTE UTS 2059 INLET 460HR 0.64 20 P 3 TWD 24 UTE

-0.59 TO+136.1 UTE UTS 2059 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.59 TO+144.9 UTE UTS 2059 INLET 460HR 58 82 2.06 28 2

TEA UTE

-0.15 UTE UTE 2059 INLET 460HR 58 84

1. 57 20 2

TEA UTE

-0.18 UTE UTE 2060 INLET 460HR 58 87 3.09 24 2

TEA UTE

-0.13 UTE UTE 2059 INLET 460HR 58 93 4.00 26 2

TEA UTE

-0.15 UTE UTE 2059 INLET 460HR 58 95 0.80 33 2

TEA UTE

-0.11 UTE UTE 2059 INLET 460HR 58 96 0.97 26 2

TEA UTE

-0.17 UTE UTE 2060 INLET 460HR 58 100 1.17 20 2

SAl UTE

-3.53 UTE UTS 2060 INLET 460HR 1.17 20 2

TWD 56 UTE

-3.53 UTE UTS 2060 INLET 460HR 58 112 0.16 88 2

VOL 014

+0.87 014 014 4117 OUTLET 520S1 0.21 67 P 3 TWD 5 014

+0.76 014 014 WAR 4117 OUTLET 520S1 1.23 28 2

TEA UTE

-0.19 UTE UTE 2059 INLET 460HR 58 117 0.57 77 2

SVI 011

+0.80 011 011 4117 OUTLET 520S1 0.57 70 P 4 TWD 40 011

+0.92 011 011 4117 OUTLET 520S1 0.11 87 2

VOL 014

+1.13 014 014 4117 OUTLET 520S1 3.08 24 2

TEA UTE

-0.15 UTE UTE 2059 INLET 460HR 58 118 0.09 115 2 VOL 014

+1.21 014 014 4117 OUTLET 520S1 58 119 0.34 88 P 3 TWD 8 010

-0.68 010 010 WAR 4117 OUTLET 520S1 0.16 64 2

VOL 014

+0.94 014 014 4117 OUTLET 520S1 58 120 0.37 72 P 3 TWD 9 010

-0.72 010 010 WAR 4117 OUTLET 520S1 58 121

1. 46 28 2

TEA UTE

-0.19 UTE UTE 2060 INLET 460HR 58 122 0.38 76 P 3 TWD 7 010

-0.79 010 010 WAR 4117 OUTLET 520S1 5.39 32 2

TEA UTE

-0.17 UTE UTE 2059 INLET 460HR 58 123 0.54 96 P 3 TWD 13 009

+0.63 009 009 WAR 4117 OUTLET 520SI 2.21 24 2

TEA UTE

-0.17 UTE UTE 2060 INLET 460HR 58 124 0.91 27 2

TEA UTE

-0.12 UTE UTE 2059 INLET 460HR 58 125 13.64 171 1 DNT 010

-0.53 010 010 4117 OUTLET 520S1 0.12 68 2

VOL 014

+1.93 014 014 4117 OUTLET 520S1 58 128 0.28 116 2 VOL 011

-0.18 011 011 4117 OUTLET 520S1 3.50 22 2

TEA UTE

-0.14 UTE UTE 2059 INLET 460HR 58 129 2.76 23 2

TEA UTE

-0.18 UTE UTE 2060 INLET 460HR 59 2

6.17 161 1 DNT LTE

+12.38 LTE LTE 4108 OUTLET 520S1 2.68 19 2

TEA UTE

-0.12 UTE UTE 2087 INLET 460HR 7.53 355 1 DNT UTE

-11. 98 UTE UTE 4027 INLET 460SI 59 3

5.39 166 1 DNT LTE

+11.56 LTE LTE 4108 OUTLET 520S1

1. 34 33 2

TEA UTE

-0.12 UTE UTE 2087 INLET 460HR 4.90 180 1 DNT UTE

-12.06 UTE UTE 4027 INLET 460S1 59 9

4.94 32 2

TEA UTE

-0.12 UTE UTE 2087 INLET 460HR 59 10 2.68 26 2

TEA UTE

-0.18 UTE UTE 2086 INLET 460HR 59 17 0.37 80 2

VOL 013

+0.79 013 013 4027 INLET 460S1 59 21 2.90 23 2

TEA UTE

-0.14 UTE UTE 2086 INLET 460HR 59 22

1. 66 32 2

TEA UTE

-0.13 UTE UTE 2087 INLET 460HR 59 23 2.16 19 2

TEA UTE

-0.23 UTE UTE 2086 INLET 460HR 59 24 2.99 26 2

TEA UTE

-0.12 UTE UTE 2087 INLET 460HR 59 28

1. 65 23 2

TEA UTE

-0.12 UTE UTE 2087 INLET 460HR 59 33 2.79 23 2

TEA UTE

-0.17 UTE UTE 2086 INLET 460HR 59 37 4.03 23 2

TEA UTE

-0.20 UTE UTE 2086 INLET 460HR 59 41

1. 89 21 2

TEA UTE

-0.19 UTE UTE 2086 INLET 460HR 59 44 2.49 25 2

TEA UTE

-0.16 UTE UTE 2087 INLET 460HR 59 48 4.97 174 1 DNT LTE

+8.64 LTE LTE 4067 INLET 460SI

Framatome ANP Inc.

05/02/02 13:29:28 Customer Name: Oconee Unit 1 Component: S/G B Page 63 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS.., MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

4.20 173 1 DNT LTE

+9.29 LTE LTE 4067 INLET 460S1 59 49 3.05 16 2

TEA UTE

-0.14 UTE UTE 2086 INLET 460HR 59 50 1.28 21 2

TEA UTE

-0.14 UTE UTE 2099 INLET 460HR 59 61 2.76 20 2

TEA UTE

-0.18 UTE UTE 2004 INLET 460HR 59 64

1. 98 24 2

TEA UTE

-0.26 UTE UTE 2003 INLET 460HR 59 68 2.86 30 2

TEA UTE

-0.17 UTE UTE 2003 INLET 460HR 0.14 86 2

SAl LTS

-0.64 LTS LTS 3001 OUTLET 460TS 0.14 86 2

TWD 27 LTS

-0.64 LTS LTS 3001 OUTLET 460TS 59 70

1. 88 25 2

TEA UTE

-0.14 UTE UTE 2073 INLET 460HR 59 74

1. 87 25 2

TEA UTE

-0.14 UTE UTE 2059 INLET 460HR 59 79 0.60 112 P 3 TWD 12 007

-0.47 007 007 WAR 4124 OUTLET 520S1 59 81 0.70 24 2

MAl UTE

-3.58 UTE UTS 2060 INLET 460HR 0.70 24 2

TWD 70 UTE

-3.58 UTE UTS 2060 INLET 460HR 59 84 6.10 29 2

TEA UTE

-0.16 UTE UTE 2059 INLET 460HR 59 87 8.62 182 1 DNT LTS

+11.10 LTS LTS 4118 OUTLET 520SI

1. 84 168 1 DNT 001

-12.24 001 001 4118 OUTLET 520SI

1. 65 184 1 DNT 001

-13.56 001 001 4118 OUTLET 520SI 59 92 3.48 342 1 DNT 002

+16.19 002 002 4118 OUTLET 520SI 4.10 29 2

TEA UTE

-0.16 UTE UTE 2059 INLET 460HR 59 93 0.92 20 2

MAl UTE

-3.82 UTE UTS 2060 INLET 460HR 0.92 20 2

TWD 56 UTE

-3.82 UTE UTS 2060 INLET 460HR 59 94 3.20 33 2

TEA UTE

-0.21 UTE UTE 2059 INLET 460HR 59 104 3.27 27 2

TEA UTE

-0.17 UTE UTE 2063 INLET 460HR 59 109 7.60 352 1 DNT LTE

+10.10 LTE LTE 4118 OUTLET 520SI 0.22 69 2

VOL 014

+0.89 014 014 4118 OUTLET 520SI 5.83 351 1 DNT UTE

-10.66 UTE UTE 4118 OUTLET 520S1

1. 85 28 2

SAl UTE

-3.32 UTE UTS 2063 INLET 460HR

1. 85 28 2

TWD 85 UTE

-3.32 UTE UTS 2063 INLET 460HR 59 110 7.55 354 1 DNT LTE

+10.52 LTE LTE 4118 OUTLET 520SI 9.40 172 1 DNT UTE

-10.87 UTE UTE 4118 OUTLET 520S1 59 115 0.54 90 P 3 TWD 13 010

-0.67 010 010 WAR 4117 OUTLET 520S1 59 117

1. 78 34 2

TEA UTE

-0.14 UTE UTE 2063 INLET 460HR 59 119 0.50 94 P 3 TWD 12 010

-0.72 010 010 WAR 4117 OUTLET 520S1 0.26 116 P 3 TWD 7 010

-0.62 010 010 WAR 4117 OUTLET 520S1 2.91 33 2

TEA UTE

-0.18 UTE UTE 2063 INLET 460HR 59 120 0.41 80 P 3 TWD 10 009

-0.68 009 009 WAR 4117 OUTLET 520S1 0.26 58 P 3 TWD 7 009

+0.69 009 009 WAR 4117 OUTLET 520S1 7.63 173 1 DNT 010

-0.53 010 010 4117 OUTLET 520S1 0.11 58 2

VOL 014

+2.58 014 014 4117 OUTLET 520SI 59 121 12.90 350 1 DNT 010

-0.55 010 010 4117 OUTLET 520SI 0.26 117 2 VOL 014

+0.88 014 014 4117 OUTLET 520S1 0.17 89 2

VOL 014

+1. 37 014 014 4117 OUTLET 520S1 0.10 71 2

VOL 014

+1. 09 014 014 4117 OUTLET 520SI 0.84 20 2

SAl UTE

-3.11 UTE UTS 2063 INLET 460HR 0.84 20 2

TWD 57 UTE

-3.11 UTE UTS 2063 INLET 460HR 59 122 7.76 354 1 DNT LTE

+10.66 LTE LTE 4117 OUTLET 520S1 0.16 72 2

VOL 014

+1. 05 014 014 4117 OUTLET 520S1 6.67 170 1 DNT UTE

-10.96 UTE UTE 4117 OUTLET 520SI 13.20 176 1 DNT 010

-0.07 010 010 4130 INLET 460S1 59 123 9.00 166 1 DNT LTE

+11. 34 LTE LTE 4117 OUTLET 520SI 7.76 169 1 DNT 010

+0.62 010 010 4117 OUTLET 520SI 0.17 82 2

VOL 014

+0.80 014 014 4117 OUTLET 520S1 0.26 83 2

VOL 014

+1. 06 014 014 4117 OUTLET 520S1 0.50 79 9

PLP 014

+1.28 014 014 4117 OUTLET 520SI 5.63 182 1 DNT UTE

-11.18 UTE UTE 4117 OUTLET 520SI 4.25 26 2

TEA UTE

-0.22 UTE UTE 2063 INLET 460HR 60 2

2.59 29 2

TEA UTE

-0.13 UTE UTE 2087 INLET 460HR 8.45 170 1 DNT UTE

-11. 94 UTE UTE 4027 INLET 460S1 0.63 113 P 3 TWD 10 010

-0.66 010 010 WAR 4027 INLET 460SI 0.37 86 2

VOL 007

+1. 43 007 007 4027 INLET 460SI 0.07 93 2

VOL 005

+1. 97 005 005 4027 INLET 460SI 1.68 181 1 DNT LTS

-11. 99 LTS LTS 4027 INLET 460SI 6.84 167 1 DNT LTS

-13.44 LTS LTS 4027 INLET 460SI 60 3

0.27 92 2

VOL 012

+0.80 012 012 4027 INLET 460SI 60 8

2.20 30 2

TEA UTE

-0.20 UTE UTE 2087 INLET 460HR 60 9

2.30 19 2

TEA UTE

-0.18 UTE UTE 2086 INLET 460HR 0.19 75 2

VOL 012

+1.32 012 012 4027 INLET 460SI 60 10 5.20 164 1 DNT LTE

+12.47 LTE LTE 4108 OUTLET 520SI 2.01 36 2

TEA UTE

-0.15 UTE UTE 2087 INLET 460HR 5.94 2

1 DNT UTE

-12.11 UTE UTE 4027 INLET 460S1 60 11 4.67 178 1 DNT LTE

+12.04 LTE LTE 4108 OUTLET 520S1 2.50 171 1 DNT LTE

+12.64 LTE LTE 4108 OUTLET 520SI 7.25 352 1 DNT UTE

-10.80 UTE UTE 4108 OUTLET 520SI 6.40 354 1 DNT UTE

-12.09 UTE UTE 4108 OUTLET 520SI 2.66 23 2

TEA UTE

-0.16 UTE UTE 2086 INLET 460HR

Framatome ANP Inc.

05/02/02 13:29:29 Customer Name: Oconee Unit 1 Component: S/G B Page 64 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -: MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

60 12 6.89 176 1 ONT LTE

+12.46 LTE LTE 4108 OUTLET 520S1 2.72 24 2

TEA UTE

-0.14 UTE UTE 2087 INLET 460HR 8.92 178 1 ONT UTE

-10.73 UTE UTE 4027 INLET 460S1 0.30 113 P 3 TWO 5 008

+0.50 008 008 WAR 4027 INLET 460S1 60 13 1.83 27 2

TEA UTE

-0.18 UTE UTE 2086 INLET 460HR 0.58 70 P 3 TWO 9 008

+0.64 008 008 WAR 4027 INLET 460SI 60 18 0.26 45 2

VOL 013

+0.79 013 013 4027 INLET 460SI 60 19 0.17 56 2

VOL 013

+1. 06 013 013 4027 INLET 460S1 0.10 70 2

VOL 013

+1.31 013 013 4027 INLET 460S1 0.28 141 2 VOL 013

+0.73 013 013 4027 INLET 460S1 60 20

1. 63 32 2

TEA UTE

-0.20 UTE UTE 2086 INLET 460HR 60 24 2.40 24 2

TEA UTE

-0.17 UTE UTE 2086 INLET 460HR 60 34 0.93 28 2

TEA UTE

-0.14 UTE UTE 2087 INLET 460HR 60 54 4.92 173 1 ONT LTE

+2.46 LTE LTE 4108 OUTLET 520SI 2.70 24 2

TEA UTE

-0.17 UTE UTE 2098 INLET 460HR 60 55 3.77 18 2

TEA UTE

-0.12 UTE UTE 2099 INLET 460HR 60 57 2.45 34 2

TEA UTE

-0.14 UTE UTE 2099 INLET 460HR 60 58 2.82 177 1 DNT 006

+4.75 006 006 4108 OUTLET 520S1 60 60 0.74 16 P 1 SCI UTE

-2.32 UTE UTS TR 2003 INLET 460HR 0.27 21 P 3 TWO 0 UTE

-2.32 TO+297.8 UTE UTS 2003 INLET 460HR 0.25 23 P 3 TWO 50 UTE

-2.32 TO+288.9 UTE UTS 2003 INLET 460HR 0.41 27 P 3 TWO 64 UTE

-2.32 TO+280.0 UTE UTS 2003 INLET 460HR 0.49 22 P 3 TWO 70 UTE

-2.32 TO+271. 1 UTE UTS 2003 INLET 460HR 0.47 25 P 3 TWO 68 UTE

-2.32 TO+262.2 UTE UTS 2003 INLET 460HR 0.42 21 P 3 TWO 65 UTE

-2.32 TO+253.3 UTE UTS 2003 INLET 460HR 0.27 25 P 3 TWO 52 UTE

-2.32 TO+244.4 UTE UTS 2003 INLET 460HR 0.34 27 P 3 TWO 59 UTE

-2.32 TO+235.6 UTE UTS 2003 INLET 460HR 0.54 33 P 3 TWO 74 UTE

-2.32 TO+226.7 UTE UTS 2003 INLET 460HR 0.42 42 P 3 TWO 65 UTE

-2.32 TO+217.8 UTE UTS 2003 INLET 460HR 0.24 38 P 3 TWO 49 UTE

-2.32 TO+208.9 UTE UTS 2003 INLET 460HR 0.09 126 P 3 TWO 29 UTE

-2.32 TO+200.0 UTE UTS 2003 INLET 460HR 0.16 183 P 3 TWO 0 UTE

-2.32 TO+l91.1 UTE UTS 2003 INLET 460HR 60 62 0.77 13 2

VOL LTS

+15.94 LTS LTS 4002 OUTLET 460S1 3.85 172 1 DNT LTS

+15.90 LTS LTS 4002 OUTLET 460S1 0.46 28 P 3 TWO 0 UTE

-0.24 TO+342.2 UTE UTS 2003 INLET 460HR 0.48 31 P 3 TWO 34 UTE

-0.24 TO+333.3 UTE UTS 2003 INLET 460HR 0.55 18 P 3 TWD 36 UTE

-0.24 TO+324.4 UTE UTS

.2003 INLET 460HR 0.48 22 P 3 TWO 34 UTE

-0.24 TO+315.6 UTE UTS 2003 INLET 460HR 0.66 21 P 3 TWO 40 UTE

-0.24 TO+306.7 UTE UTS 2003 INLET 460HR 0.58 26 P 3 TWO 0 UTE

-0.24 TO+297.8 UTE UTS 2003 INLET 460HR 1.13 20 P 1 SCI UTE

-0.24 UTE UTS CL 2003 INLET 460HR 60 65 2.85 165 1 DNT 003

+15.73 003 003 4002 OUTLET 460S1 60 67 2.43 17 2

TEA UTE

-0.16 UTE UTE 2004 INLET 460HR 60 68 2.16 19 2

TEA UTE

-0.21 UTE UTE 2003 INLET 460HR 60 72 3.77 19 2

TEA UTE

-0.13 UTE UTE 2004 INLET 460HR 60 75 1.57 19 2

TEA UTE

-0.12 UTE UTE 2108 INLET 460HR 60 79 2.23 17 2

TEA UTE

-0.13 UTE UTE 2063 INLET 460HR 60 81 3.82 29 2

TEA UTE

-0.19 UTE UTE 2063 INLET 460HR 60 86 5.81 27 2

TEA UTE

-0.31 UTE UTE 2064 INLET 460HR 60 87 4.19 27 2

TEA UTE

-0.25 UTE UTE 2063 INLET 460HR 60 88 3.40 25 2

TEA UTE

-0.16 UTE UTE 2064 INLET 460HR 60 89 3.39 21 2

TEA UTE

-0.18 UTE UTE 2063 INLET 460HR 60 90 0.19 75 2

VOL 003

+14.24 003 003 4124 OUTLET 520S1 2.75 36 2

TEA UTE

-0.22 UTE UTE 2064 INLET 460HR 60 91 6.07 180 1 ONT LTE

+10.22 LTE LTE 4118 OUTLET 520S1 7.70 178 1 DNT UTE

-11. 37 UTE UTE 4118 OUTLET 520S1 3.86 22 2

TEA UTE

-0.14 UTE UTE 2063 INLET 460HR 60 92 6.98 173 1 DNT LTE

+11.18 LTE LTE 4118 OUTLET 520S1 11.20 170 1 DNT UTE

-11. 21 UTE UTE 4118 OUTLET 520SI 3.94 22 2

TEA UTE

-0.20 UTE UTE 2064 INLET 460HR 60 95 3.04 27 2

TEA UTE

-0.20 UTE UTE 2063 INLET 460HR 60 100 2.53 18 2

TEA UTE

-0.11 UTE UTE 2063 INLET 460HR 60 101 2.65 21 2

TEA UTE

-0.19 UTE UTE 2063 INLET 460HR 60 106 2.17 39 2

TEA UTE

-0.16 UTE UTE 2063 INLET 460HR 60 108 4.19 32 2

TEA UTE

-0.17 UTE UTE 2063 INLET 460HR 60 111 2.14 19 2

TEA UTE

-0.11 UTE UTE 2064 INLET 460HR 60 115 7.32 354 1 DNT LTE

+10.12 LTE LTE 4118 OUTLET 520S1 9.61 174 1 DNT UTE

-10.76 UTE UTE 4118 OUTLET 520SI 60 118 0.66 26 2

VOL 014

+1. 02 014 014 4118 OUTLET 520SI 0.29 78 9

PLP 014

+1. 21 014 014 4118 OUTLET 520SI 60 119 8.72 353 1 ONT 014

-2.71 014 014 4118 OUTLET 520SI 60 121 0.50 93 P 3 TWO 11 010

-0.73 010 010 WAR 4118 OUTLET 520SI 60 122 1.11 25 2

TEA UTE

-0.16 UTE UTE 2063 INLET 460HR 60 124 2.81 28 2

TEA UTE

-0.24 UTE UTE 2064 INLET 460HR 60 129 0.25 84 2

VOL 004

+0.85 004 004 4118 OUTLET 520SI

Framatome ANP Inc.

05/02/02 13:29:29 Customer Name: Oconee Unit 1 Component: S/G B Page 65 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL II LEG PROBE

============
===

0.38 88 P 3 TWD 9 008

-0.83 008 008 WAR 4118 OUTLET 520SI 61 3

3.85 26 2

TEA UTE

-0.17 UTE UTE 2087 INLET 460HR 0.48 71 P 3 TWO 7 008

+0.61 008 008 WAR 4027 INLET 460SI 0.29 58 2

VOL 005

+0.81 005 005 4027 INLET 460SI 61 4

1.48 27 2

TEA UTE

-0.12 UTE UTE 2087 INLET 460HR 61 7

2.64 24 2

TEA UTE

-0.16 UTE UTE 2087 INLET 460HR 61 9

3.48 25 2

TEA UTE

-0.14 UTE UTE 2087 INLET 460HR 61 10 2.26 353 1 ONT LTE

+7.76 LTE LTE 4108 OUTLET 520SI 5.65 179 1 ONT LTE

+12.24 LTE LTE 4108 OUTLET 520SI 7.78 352 1 DNT UTE

-9.60 UTE UTE 4027 INLET 460SI 7.62 352 1 DNT UTE

-13.22 UTE UTE 4027 INLET 460SI 3.53 22 2

TEA UTE

-0.23 UTE UTE 2126 INLET 460HR 61 13 1.33 23 2

TEA UTE

-0.11 UTE UTE 2087 INLET 460HR 0.45 107 P 3 TWD 7 009

-0.59 009 009 WAR 4027 INLET 460SI 61 15 0.21 79 2

VOL 014

+0.85 014 014 4027 INLET 460SI 61 16 0.70 67 1

VOL 010

+5.85 010 010 4027 INLET 460SI 61 17

1. 95 17 2

TEA UTE

-0.21 UTE UTE 2086 INLET 460HR 61 18 0.19 78 2

VOL 013

+0.94 013 013 4027 INLET 460SI 61 19 0.30 89 P 3 TWD 5 008

-0.28 008 008 WAR 4027 INLET 460SI 61 25 3.03 16 2

TEA UTE

-0.14 UTE UTE 2086 INLET 460HR 61 30 4.72 25 2

TEA UTE

-0.13 UTE UTE 2087 INLET 460HR 61 45 2.10 16 2

TEA UTE

-0.13 UTE UTE 2086 INLET 460HR 61 50

1. 85 21 2

TEA UTE

-0.07 UTE UTE 2087 INLET 460HR 61 54 3.72 22 2

TEA UTE

-0.18 UTE UTE 2099 INLET 460HR 61 67 4.36 29 2

TEA UTE

-0.23 UTE UTE 2004 INLET 460HR 61 75

1. 44 22 2

TEA UTE

-0.17 UTE UTE 2108 INLET 460HR 61 77 2.98 27 2

TEA UTE

-0.05 UTE UTE 2064 INLET 460HR 61 78

1. 67 18 2

TEA UTE

-0.24 UTE UTE 2063 INLET 460HR 61 80 3.53 31 2

TEA UTE

-0.20 UTE UTE 2063 INLET 460HR 61 81 2.08 26 P 1 SCI UTE

-0.24 UTE UTS CL 2064 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.24 TO+223.3 UTE UTS 2064 INLET 460HR 0.44 43 P 3 TWD 24 UTE

-0.24 TO+232.4 UTE UTS 2064 INLET 460HR

1. 05 25 P 3 TWD 58 UTE

-0.24 TO+241. 5 UTE UTS 2064 INLET 460HR

1. 80 22 P 3 TWD 100 UTE

-0.24 TO+250.6 UTE UTS 2064 INLET 460HR

1. 66 23 P 3 TWD 92 UTE

-0.24 TO+259.7 UTE UTS 2064 INLET 460HR 1.02 27 P 3 TWO 57 UTE

-0.24 TO+268.9 UTE UTS 2064 INLET 460HR 0.83 30 P 3 TWO 46 UTE

-0.24 TO+278.0 UTE UTS 2064 INLET 460HR 0.76 34 P 3 TWO 42 UTE

-0.24 TO+287.1 UTE UTS 2064 INLET 460HR 0.51 34 P 3 TWD 28 UTE

-0.24 TO+296.2 UTE UTS 2064 INLET 460HR 0.29 26 P 3 TWD 16 UTE

-0.24 TO+305.3 UTE UTS 2064 INLET 460HR 0.17 27 P 3 TWD 9 UTE

-0.24 TO+314.4 UTE UTS 2064 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.24 TO+323.5 UTE UTS 2064 INLET 460HR 61 88 8.43 180 1 ONT LTE

+11.05 LTE LTE 4118 OUTLET 520SI 12.74 178 1 ONT UTE

-10.99 UTE UTE 4118 OUTLET 520SI 4.75 26 2

TEA UTE

-0.18 UTE UTE 2064 INLET 460HR 61 89 16.18 20 1

SCI LTE

+2.08 LTE LTE 724 OUTLET 380EX 8.59 16 1

SCI LTE

+0.40 LTE LTE 724 OUTLET 380EX 61 90 5.59 168 1 ONT LTE

+10.05 LTE LTE 4118 OUTLET 520SI 8.11 169 1 DNT UTE

-10.98 UTE UTE 4118 OUTLET 520SI 3.58 32 2

TEA UTE

-0.18 UTE UTE 2063 INLET 460HR 61 93 2.15 42 2

TEA UTE

-0.17 UTE UTE 2064 INLET 460HR 61 95 3.91 29 P 1 SCI UTE

-0.22 UTE UTS CL 2064 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.22 TO+177.7 UTE UTS 2064 INLET 460HR 2.54 23 P 3 TWD 30 UTE

-0.22 TO+186.8 UTE UTS 2064 INLET 460HR 4.60 18 P 3 TWO 54 UTE

-0.22 TO+195.9 UTE UTS 2064 INLET 460HR 2.95 17 P 3 TWD 35 UTE

-0.22 TO+205.1 UTE UTS 2064 INLET 460HR 0.41 20 P 3 TWD 5 UTE

-0.22 TO+214.2 UTE UTS 2064 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.22 TO+223.3 UTE UTS 2064 INLET 460HR 61 100 4.02 27 2

TEA UTE

-0.29 UTE UTE 2109 INLET 460HR 61 103 6.89 28 2

TEA UTE

-0.28 UTE UTE 2064 INLET 460HR 61 105

1. 87 21 2

TEA UTE

-0.20 UTE UTE 2064 INLET 460HR 61 106 2.32 28 2

TEA UTE

-0.20 UTE UTE 2063 INLET 460HR 61 107

1. 42 12 2

TEA UTE

-0.27 UTE UTE 2064 INLET 460HR 61 108 4.01 34 2

TEA UTE

-0.25 UTE UTE 2063 INLET 460HR 61 109 9.43 346 1 ONT LTE

+11.24 LTE LTE 4118 OUTLET 520SI 0.36 126 2 VOL 012

+0.65 012 012 4118 OUTLET 520SI 0.16 82 2

VOL 012

+1.17 012 012 4118 OUTLET 520SI 11.13 168 1 DNT UTE

-11. 63 UTE UTE 4118 OUTLET 520SI 3.00 20 2

TEA UTE

-0.24 UTE UTE 2064 INLET 460HR 61 111 7.99 354 1 ONT LTE

+9.88 LTE LTE 4118 OUTLET 520SI 0.26 92 P 3 TWO 6 009

+0.70 009 009 WAR 4118 OUTLET 520SI 7.70 356 1 ONT UTE

-10.94 UTE UTE 4118 OUTLET 520SI 2.08 35 2

TEA UTE

-0.13 UTE UTE 2063 INLET 460HR 61 112

1. 94 27 2

TEA UTE

-0.17 UTE UTE 2064 INLET 460HR 61 113 0.14 80 2

VOL 012

-0.85 012 012 4118 OUTLET 520SI

Frarnatorne ANP Inc.

Customer Name: Oconee unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 61 61 61 61 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 117 118 119 121 3

5 6

8 9

32 37 52 57 63 77 81 82 83 84 86 88 89 91 92 98 99 100 102 107 110 112 113 115 117 121 122 1.53 0.70 0.28 0.74 2.89 0.39 2.63 0.71 0.14 1.47 0.42 0.30 0.18 0.27 0.15 3.77 3.78 7.59 6.15

1. 77 2.95 6.01 4.37 9.93 0.86 0.86 6.08 7.13 6.82 0.00 0.70 2.49 4.67 5.69 5.40 3.59 2.08 0.00 0.13
1. 80 1.06 0.13 0.13 8.68 10.94 5.07 9.32 13.09 3.22 3.86 0.00 1.35 2.64 3.60 2.89 1.24 0.00 4.97 1.57 5.66 0.84 2.25 4.56 4.55 2.45 4.04 0.10 4.34 2.38 3.84 0.41 2.82 0.13 2.40 1.52 2

TEA 36 100 32 109 35 108 26 P 3 TWO 15 2

VOL P 3 TWO 16 2

TEA P 3 TWO 9 2

TEA 99 P

82 2

33 2

72 2

45 2

75 2

58 2

65 2

21 2

173 1 178 1 27 2

22 2

31 2

22 2

3 TWO 11 171 174 23 23 30 22 27 o

37 32 25 25 24 28 33 o

122 25 29 84 84 174 175 27 176 179 20 1

1 2

2 2

2 P 1 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 2

2 2

2 2

1 1

2 1

1 2

VOL TEA VOL VOL VOL VOL VOL TEA ONT ONT TEA TEA TEA TEA ONT ONT SVI TWO 67 TEA TEA SCI TWO 0 12 43 81 99 94 62 36 o

TWO TWO TWO TWO TWO TWO TWO TWO VOL TEA TEA SAl TWO 17 ONT DNT TEA DNT ONT TEA SCI TWO 0 TWO 23 TWO TWO TWO TWO TWO TEA TEA TEA TEA TEA ONT ONT TEA ONT VOL DNT TEA TEA 45 62 50 21 o

20 P 1 o

P 3 15 P 3 19 P 3 19 P 3 18 P 3 20 P 3 o

P 3 30 2

28 2

34 2

27 2

26 2

158 1 165 1 35 2

161 1 78 2

161 1 29 2

32 2

75 P 3 TWO 9 2

TEA 29 85 32 24 2

VOL 2

2 TEA TEA UTE 010 014 010 UTE 010 UTE 010 014 UTE 012 009 013 014 011 UTE LTE UTE UTE UTE UTE UTE LTE 001 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTE UTE 014 014 LTE UTE UTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE UTE UTE LTE 014 UTE UTE UTE 010 UTE 014 UTE UTE

-0.12

-0.62

+0.68

-0.66

-0.20

-0.64

-0.24

-0.68

+0.99

-0.26

+1.22

+1.60

+1. 23

+0.77

+1.16

-0.15

+8.26

-7.94

-0.12

-0.15

-0.12

-0.24

+10.56

-7.36

-0.49

-0.49

-0.18

-0.22

-0.11

-0.11

-0.11

-0.11

-0.11

-0.11

-0.11

-0.11

-0.11

-0.11

-10.87

-0.19

-0.15

+5.52

+5.52

+10.94

-11. 07

-0.10

+10.27

-11. 33

-0.14

-0.34

-0.34

-0.34

-0.34

-0.34

-0.34

-0.34

-0.34

-0.11

-0.21

-0.15

-0.23

-0.19

+12.43

-12.75

-0.20

+12.42

+1.07

-12.26

-0.26

-0.31

-0.64

-0.22

+0.98

-0.18

-0.22 TO+O.O TO+8.8 TO+17.6 TO+26.3 TO+35.1 TO+43.9 TO+52.7 TO+61.5 TO+70.2 TO+74.6 TO+83.4 TO+92.2 TO+101. 0 TO+109.8 TO+118.5 TO+127.3 05/02/02 13:29:30 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE 010 010 014 014 010 010 UTE UTE 010 010 UTE UTE 010 010 014 014 UTE UTE 012 012 009 009 013 013 014 014 011 011 UTE UTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTS 001 001 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UT8 UTE UT8 UTE UT8 UTE UT8 UTE UT8 UTE UT8 UTE UTS UTE UT8 UT8 UT8 UTE UTE UTE UTE 014 014 014 014 LTE LTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE UTE UT8 UTE UT8 UTE UT8 UTE UT8 UTE UTS UTE UTS UTE UT8 UTE UT8 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE LTE LTE 014 014 UTE UTE UTE UTE UTE UTE 010 010 UTE UTE 014 014 UTE UTE UTE UTE WAR WAR WAR WAR C8 CL TR WAR 2063 4118 4118 4118 2063 4118 2064 4118 4118 2063 4027 4027 4027 4027 4027 2086 4108 4027 2087 2086 2087 2098 4006 4124 2063 2063 2063 2064 2063 2063 2063 2063 2063 2063 2063 2063 2063 2063 4124 2063 2063 4124 4124 4118 4118 2064 4118 4118 2063 2063 2063 2063 2063 2063 2063 2063 2063 2064 2063 2063 2064 2063 4119 4119 2063 4119 4119 4119 2064 2064 4119 2064 4119 2063 2064 INLET OUTLET OUTLET OUTLET INLET OUTLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET OUTLET INLET INLET Page 66 of 155 PROBE 460HR 520SI 520SI 52081 460HR 520SI 460HR 52081 52081 460HR 460SI 46081 460SI 46081 46081 460HR 520SI 460SI 460HR 460HR 460HR 460HR 460SI 520SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 52081 460HR 460HR 52081 52081 520SI 520S1 460HR 520SI 520S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 520SI 520SI 460HR 52081 52081 520SI 460HR 460HR 520SI 460HR 520SI 460HR 460HR

Framatome ANP Inc.

05/02/02 13:29:31 Customer Name: Oconee Unit 1 Component: S/G B Page 67 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

62 123 0.57 68 P 3 TWD 13 010

-0.59 010 010 WAR 4119 OUTLET 520S1 0.11 116 2 VOL 014

+0.83 014 014 4119 OUTLET

. 520S1 3.07 34 2

TEA UTE

-0.24 UTE UTE 2063 INLET 460HR 62 124 2.22 25 2

TEA UTE

-0.31 UTE UTE 2064 INLET 460HR 62 125 0.12 52 2

VOL 011

+1.00 011 011 4119 OUTLET 520S1 4.69 30 2

TEA UTE

-0.20 UTE UTE 2063 INLET 460HR 62 126

1. 30 19 2

TEA UTE

-0.12 UTE UTE 2064 INLET 460HR 62 128 0.21 73 2

VOL 014

+2.17 014 014 4119 OUTLET 520S1 0.36 74 9

PLP 014

+1. 22 014 014 4119 OUTLET 520S1 2.49 30 2

TEA UTE

-0.18 UTE UTE 2063 INLET 460HR 62 129 3.14 19 2

TEA UTE

-0.12 UTE UTE 2064 INLET 460HR 63 2

5.39 16 P 1 DRS UTE

-0.77 UTE UTE SLV 1001 INLET 400PS 0.39 84 p 3 TWD 9 006

+0.17 006 006 WAR 4054 OUTLET 460S1 63 5

1. 92 24 2

TEA UTE

-0.14 UTE UTE 2087 INLET 460HR 0.16 63 2

VOL 011

+1. 55 011 011 4027 INLET 460S1 63 6

1. 94 20 2

TEA UTE

-0.15 UTE UTE 2086 INLET 460HR 63 10 3.28 178 1 DNT LTE

+7.74 LTE LTE 4108 OUTLET 520S1 3.18 28 2

TEA UTE

-0.18 UTE UTE 2086 INLET 460HR 7.34 178 1 DNT UTE

-8.13 UTE UTE 4027 INLET 460S1 0.26 61 2

VOL 013

+0.90 013 013 4027 INLET 460S1 63 19 2.79 23 2

TEA UTE

-0.23 UTE UTE 2086 INLET 460HR 63 21 2.75 23 2

TEA UTE

-0.20 UTE UTE 2086 INLET 460HR 63 24 4.34 29 2

TEA UTE

-0.11 UTE UTE 2087 INLET 460HR 63 49 0.27 114 2 VOL LTS

+21.18 LTS LTS 4108 OUTLET 520S1 63 51 2.76 180 1 DNT LTS

-0.10 LTS LTS 4067 INLET 460S1 63 58 0.86 41 2

MAl UTE

-3.47 UTE UTS 2098 INLET 460HR 0.86 41 2

TWD 92 UTE

-3.47 UTE UTS 2098 INLET 460HR 63 71 0.61 21 2

SVI UTE

-3.37 UTE UTS TR 2004 INLET 460HR 0.61 21 2

TWD 62 UTE

-3.37 UTE UTS 2004 INLET 460HR 63 72 4.58 25 2

TEA UTE

-0.27 UTE UTE 2003 INLET 460HR 63 73 2.67 19 2

TEA UTE

-0.38 UTE UTE 2004 INLET 460HR 63 74 5.25 173 1 DNT 015

'-4.22 015 015 4124 OUTLET 520S1 63 79 3.10 24 2

TEA UTE

-0.18 UTE UTE 2063 INLET 460HR 63 81 0.88 22 2

TEA UTE

-0.11 UTE UTE 2063 INLET 460HR 63 82 6.52 27 2

TEA UTE

-0.24 UTE UTE 2064 INLET 460HR 63 85

1. 55 17 2

SAl UTE

-3.22 UTE UTS 2063 INLET 460HR

1. 55 17 2

TWD 47 UTE

-3.22 UTE UTS 2063 INLET 460HR 63 89 4.29 33 2

TEA UTE

-0.16 UTE UTE 2063 INLET 460HR 63 95 2.89 30 2

TEA UTE

-0.10 UTE UTE 2064 INLET 460HR 1.05 18 2

SAl UTE

-1.29 UTE UTE TR 2064 INLET 460HR

1. 05 18 2

TWD 51 UTE

-1.29 UTE UTE 2064 INLET 460HR 63 96 2.07 26 2

TEA UTE

-0.12 UTE UTE 2063 INLET 460HR 63 102 0.26 0

p 3 TWD 7 007

-0.44 007 007 WAR 4119 OUTLET 520S1 63 108 4.90 27 2

TEA UTE

-0.15 UTE UTE 2063 INLET 460HR 63 109 2.48 28 2

TEA UTE

-0.20 UTE UTE 2064 INLET 460HR 63 110 3.06 30 2

TEA UTE

-0.14 UTE UTE 2063 INLET 460HR 63 113 0.56 56 P 3 TWD 12 007

-0.57 007 007 WAR 4119 OUTLET 520S1 6.64 31 2

TEA UTE

-0.12 UTE UTE 2063 INLET 460HR 63 116 0.29 0

P 3 TWD 7 009

+0.58 009 009 WAR 4119 OUTLET 520S1 63 118 0.40 73 P 3 TWD 9 009

-0.45 009 009 WAR 4119 OUTLET 520S1 2.67 26 2

TEA UTE

-0.17 UTE UTE 2063 INLET 460HR 63 121 0.24 61 P 3 TWD 6 009

+0.59 009 009 WAR 4119 OUTLET 520SI 0.11 85 2

VOL 014

+0.82 014 014 4119 OUTLET 520SI 63 122 0.31 70 P 3 TWD 7 009

+0.67 009 009 WAR 4119 OUTLET 520SI 1..20 24 2

SAl UTE

-3.11 UTE UTS 2063 INLET 460HR

1. 20 24 2

TWD 70 UTE

-3.11 UTE UTS 2063 INLET 460HR 63 124 0.48 85 P 3 TWD 11 010

-0.32 010 010 WAR 4119 OUTLET 520S1 5.61 29 2

TEA UTE

-0.16 UTE UTE 2063 INLET 460HR 63 126 9.01 177 1 DNT UTE

-10.94 UTE UTE 4123 OUTLET 520S1 2.73 164 1 DNT LTE

+10.54 LTE LTE 4119 OUTLET 520SI 0.16 69 2

VOL 014

+1.32 014 014 4119 OUTLET 520S1 63 129 0.42 49 2

VOL 014

+1.80 014 014 4119 OUTLET 520S1 0.22 79 9

PLP 014

+1.80 014 014 4119 OUTLET 520S1 64 3

9.38 22 P 1 DRS UTE

-0.81 UTE UTE SLV 1001 INLET 400PS 64 6

2.17 30 2

TEA UTE

-0.14 UTE UTE 2087 INLET 460HR 64 8

2.89 27 2

TEA UTE

-0.16 UTE UTE 2087 INLET 460HR 64 11 2.84 21 2

TEA UTE

-0.20 UTE UTE 2086 INLET 460HR 64 13 3.13 27 2

TEA UTE

-0.12 UTE UTE 2086 INLET 460HR 64 14

1. 59 23 2

TEA UTE

-0.16 UTE UTE 2087 INLET 460HR 64 15 0.16 46 2

VOL 014

+1.15 014 014 4027 INLET 460S1 64 20

1. 04 23 2

TEA UTE

-0.16 UTE UTE 2087 INLET 460HR 64 22 4.29 30 2

TEA UTE

-0.12 UTE UTE 2087 INLET 460HR 64 29

1. 58 21 2

TEA UTE

-0.18 UTE UTE 2086 INLET 460HR 64 32 3.27 22 2

TEA UTE

-0.13 UTE UTE 2086 INLET 460HR 64 34 4.01 21 2

TEA UTE

-0.14 UTE UTE 2086 INLET 460HR

Framatome ANP Inc.

05/02/02 13:29:31 Customer Name: Oconee Unit 1 Component: S/G B Page 68 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

64 36 2.71 24 2

TEA UTE

-0.17 UTE UTE 2086 INLET 460HR 64 38 0.23 151 P 3 TWO 3 007

+0.42 007 007 WAR 4067 INLET 460SI 64 45 1.94 25 2

TEA UTE

-0.15 UTE UTE 2087 INLET 460HR 64 48 3.50 25 2

TEA UTE

-0.19 UTE UTE 2086 INLET 460HR 64 53 3.39 37 2

DNT 015

+17.98 015 015 4108 OUTLET 520SI 64 57 0.68 18 P 1 SCI UTE

-3.58 UTE UTS 2098 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.58 TO+302.2 UTE UTS 2098 INLET 460HR 0.37 9

P 3 TWO 65 UTE

-3.58 TO+311.1 UTE UTS 2098 INLET 460HR 0.40 22 P 3 TWD 70 UTE

-3.58 TO+320.0 UTE UTS 2098 INLET 460HR 0.31 18 P 3 TWD 54 UTE

-3.58 TO+328.9 UTE UTS 2098 INLET 460HR 0.24 9

P 3 TWD 43 UTE

-3.58 TO+337.8 UTE UTS 2098 INLET 460HR 0.23 12 P 3 TWO 39 UTE

-3.58 TO+346.7 UTE UTS 2098 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.58 TO+355.6 UTE UTS 2098 INLET 460HR 64 62 5.35 179 1 DNT 014

+3.26 014 014 4002 OUTLET 460SI 64 71 6.49 22 2

TEA UTE

-0.13 UTE UTE 2003 INLET 460HR 64 73 4.04 22 2

TEA UTE

-0.20 UTE UTE 2003 INLET 460HR 64 81 2.35 28 2

TEA UTE

-0.18 UTE UTE 2064 INLET 460HR 64 87

1. 87 23 2

TEA UTE

-0.18 UTE UTE 2063 INLET 460HR 64 88 3.55 21 2

TEA UTE

-0.14 UTE UTE 2063 INLET 460HR 64 92 1.57 22 2

TEA UTE

-0.13 UTE UTE 2063 INLET 460HR 64 94 2.61 18 2

TEA UTE

-0.14 UTE UTE 2063 INLET 460HR 64 95 4.67 28 2

TEA UTE

-0.20 UTE UTE 2064 INLET 460HR 64 103 3.17 28 2

TEA UTE

-0.20 UTE UTE 2064 INLET 460HR 64 109 0.63 39 2

TEA UTE

-0.26 UTE UTE 2064 INLET 460HR 64 111 1.58 28 2

TEA UTE

-0.14 UTE UTE 2064 INLET 460HR 64 113

1. 67 33 2

TEA UTE

-0.21 UTE UTE 2064 INLET 460HR 64 115 3.61 32 2

TEA UTE

-0.17 UTE UTE 2063 INLET 460HR 64 116 0.49 64 P 3 TWD 9 009

-0.28 009 009 WAR 4123 OUTLET 520SI 0.16 83 2

VOL 014

+1. 30 014 014 4123 OUTLET 520SI 64 117 0.36 88 P 3 TWD 7 009

+0.10 009 009 WAR 4123 OUTLET 520SI 2.88 29 2

TEA UTE

-0.14 UTE UTE 2063 INLET 460HR 64 118 0.35 84 P 3 TWD 8 009

+0.08 009 009 WAR 4119 OUTLET 52081 64 120 0.45 0

P 3 TWO 11 009

+0.00 009 009 WAR 4119 OUTLET 520SI 64 121 0.38 158 2 VOL 009

+0.02 009 009 4119 OUTLET 520SI 0.35 67 2

VOL 012

-0.71 012 012 4119 OUTLET 520SI 4.88 31 2

TEA UTE

-0.18 UTE UTE 2063 INLET 460HR 64 123 0.35 88 P 3 TWO 7 014

+0.78 014 014 WAR 4123 OUTLET 520SI 7.86 172 1 ONT UTE

-10.99 UTE UTE 4123 OUTLET 52081 5.55 175 1 DNT LTE

+10.89 LTE LTE 4119 OUTLET 52081 2.63 35 2

TEA UTE

-0.17 UTE UTE 2063 INLET 460HR 64 126 0.07 69 2

VOL 014

+1. 00 014 014 4123 OUTLET 520SI 7.13 351 1 ONT UTE

-10.60 UTE UTE 4123 OUTLET 520SI 6.15 177 1 DNT UTE

-9.97 UTE UTE 4123 OUTLET 520SI 8.52 177 1 DNT UTE

-10.60 UTE UTE 4123 OUTLET 52081 5.77 173 1 DNT LTE

+11.43 LTE LTE 4130 INLET 460SI

1. 76 30 2

TEA UTE

-0.13 UTE UTE 2063 INLET 460HR 64 127

1. 61 18 2

TEA UTE

-0.16 UTE UTE 2063 INLET 460HR 65 3

8.22 20 P 1 DRS UTE

-0.75 UTE UTE SLV 1001 INLET 400PS

1. 97 28 P 1 DRS 015

-4.35 015 015 SLV 1001 INLET 400PS 2.85 26 P 1 DRS 015

-6.33 015 015 SLV 1001 INLET 400PS 0.91 122 P 3 TWD 19 009

-0.75 009 009 WAR 4054 OUTLET 460SI 0.34 110 P 3 TWO 8 010

+0.15 010 010 WAR 4054 OUTLET 460SI 65 4

5.04 20 P 1 DR8 UTE

-0.61 UTE UTE SLY 1001 INLET 400PS 0.57 116 P 3 TWO 11 010

+0.15 010 010 WAR 4054 OUTLET 460SI 65 6

3.09 21 2

TEA UTE

-0.15 UTE UTE 2087 INLET 460HR 65 7

0.22 83 2

VOL 013

+1.03 013 013 4027 INLET 46081 65 8

2.55 21 2

TEA UTE

-0.13 UTE UTE 2087 INLET 460HR 65 11 1.40 18 2

TEA UTE

-0.31 UTE UTE 2086 INLET 460HR 65 12 2.89 27 2

TEA UTE

-0.17 UTE UTE 2087 INLET 460HR 65 13 3.41 23 2

TEA UTE

-0.31 UTE UTE 2086 INLET 460HR 65 18 2.78 178 1 ONT LTE

+8.40 LTE LTE 4108 OUTLET 520SI 65 19 2.29 32 2

TEA UTE

-0.16 UTE UTE 2087 INLET 460HR 65 21 2.15 33 2

TEA UTE

-0.12 UTE UTE 2087 INLET 460HR 65 23 0.46 29 P 4 8VI UTE

-3.56 UTE UTE 2087 INLET 460HR 0.48 30 P 4 TWO 94 UTE

-3.56 UTE UTE 2087 INLET 460HR 65 34 2.18 19 2

TEA UTE

-0.16 UTE UTE 2086 INLET 460HR 65 38 2.17 165 1 DNT UTS

+4.04 UTS UTS 4067 INLET 460SI 2.99 165 1 DNT UTS

+4.87 UTS UTS 4067 INLET 460SI

1. 86 188 1 DNT UT8

+5.82 UTS UTS 4067 INLET 460SI 3.20 181 1 DNT UTS

+6.72 UTS UTS 4067 INLET 460SI 1.90 194 1 DNT UTS

+7.50 UTS UTS 4067 INLET 460SI 65 43 2.63 169 1 ONT UTE

-5.08 UTE UTE 4063 INLET 460SI 2.88 172 1 DNT UTE

-5.62 UTE UTE 4063 INLET 460S1 3.57 165 1 DNT UTE

-6.11 UTE UTE 4063 INLET 460SI 4.87 180 1 DNT UTE

-8.84 UTE UTE 4063 INLET 460SI

Framatome ANP Inc.

05/02/02 13:29:32 Customer Name: Oconee Unit 1 Component: S/G B Page 69 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

65 45 2.01 23 2

TEA UTE

-0.14 UTE UTE 2087 INLET 460HR 65 54 4.91 28 2

TEA UTE

-0.17 UTE UTE 2098 INLET 460HR 65 57 2.21 27 2

TEA UTE

-0.16 UTE UTE 2099 INLET 460HR 65 58 3.20 23 2

TEA UTE

-0.13 UTE UTE 2098 INLET 460HR 65 62 0.00 0

P 3 TWD 0 UTE

-0.18 TO+4.3 UTE UTS 2007 INLET 460HR 0.20 32 P 3 TWD 9 UTE

-0.18 TO+13.0 UTE UTS 2007 INLET 460HR 0.96 9

P 3 TWD 44 UTE

-0.18 TO+21.7 UTE UTS 2007 INLET 460HR 1.23 11 P 3 TWD 56 UTE

-0.18 TO+30.4 UTE UTS 2007 INLET 460HR 1.18 11 P 3 TWD 54 UTE

-0.18 TO+39.0 UTE UTS 2007 INLET 460HR 0.87 17 P 3 TWD 40 UTE

-0.18 TO+47.7 UTE UTS 2007 INLET 460HR 0.65 16 P 3 TWD 30 UTE

-0.18 TO+56.4 UTE UTS 2007 INLET 460HR 0.16 49 P 3 TWD 7 UTE

-0.18 TO+65.1 UTE UTS 2007 INLET 460HR 0.70 35 P 3 TWD 32 UTE

-0.18 TO+73.7 UTE UTS 2007 INLET 460HR

1. 79 32 P 1 SCI UTE

-0.18 UTE UTS CL 2007 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.18 TO+82.4 UTE UTS 2007 INLET 460HR 65 63 0.97 15 2

TEA UTE

-0.20 UTE UTE 2007 INLET 460HR 65 64 4.67 170 1 DNT LTE

+11. 01 LTE LTS 4006 OUTLET 460SI 65 68 3.72 22 2

TEA UTE

-0.24 UTE UTE 2003 INLET 460HR 65 71 3.43 23 2

TEA UTE

-0.25 UTE UTE 2004 INLET 460HR 65 84 2.09 25 2

TEA UTE

-0.15 UTE UTE 2063 INLET 460HR 65 85 4.89 26 2

TEA UTE

-0.27 UTE UTE 2064 INLET 460HR 65 87 2.86 33 2

TEA UTE

-0.20 UTE UTE 2063 INLET 460HR 65 88 7.83 26 2

TEA UTE

-0.25 UTE UTE 2064 INLET 460HR 65 90 4.59 25 2

TEA UTE

-0.18 UTE UTE 2064 INLET 460HR 65 91 7.06 27 2

TEA UTE

-0.37 UTE UTE 2109 INLET 460HR 65 94 5.08 20 2

TEA UTE

-0.24 UTE UTE 2064 INLET 460HR 65 96 2.70 32 2

TEA UTE

-0.17 UTE UTE 2063 INLET 460HR 65 99 5.78 28 2

TEA UTE

-0.16 UTE UTE 2064 INLET 460HR 65 105 5.31 26 2

TEA UTE

-0.12 UTE UTE 2064 INLET 460HR 65 106 5.30 31 2

TEA UTE

-0.25 UTE UTE 2063 INLET 460HR 65 107 4.45 25 2

TEA UTE

-0.24 UTE UTE 2064 INLET 460HR 65 109 4.25 23 2

TEA UTE

-0.21 UTE UTE 2064 INLET 460HR 65 112 4.13 35 2

TEA UTE

-0.31 UTE UTE 2063 INLET 460HR 65 116 1.16 33 2

TEA UTE

-0.25 UTE UTE 2063 INLET 460HR 65 117 3.05 45 2

TEA UTE

-0.25 UTE UTE 2064 INLET 460HR 65 118 3.42 25 2

TEA UTE

-0.22 UTE UTE 2063 INLET 460HR 65 119 0.56 78 2

VOL 007

-0.59 007 007 4119 OUTLET 520SI 0.56 78 P 4 SVI 007

-0.70 007 007 4119 OUTLET 520SI 0.56 78 P 4 TWD 32 007

-0.70 007 007 4119 OUTLET 520SI 0.47 39 P 3 TWD 11 010

-0.68 010 010 WAR 4119 OUTLET 520SI 65 1,23 3.66 30 2

TEA UTE

-0.27 UTE UTE 2064 INLET 460HR 65 124 6.53 174 1 DNT UTS

+11. 52 UTS UTS 4123 OUTLET 520SI 3.68 161 1 DNT LTE

+11.27 LTE LTE 4119 OUTLET 520SI 2.73 23 2

TEA UTE

-0.20 UTE UTE 2063 INLET 460HR 65 129 0.24 124 2 VOL 015

+0.75 015 015 4119 OUTLET 520SI

1. 68 35 2

TEA UTE

-0.16 UTE UTE 2063 INLET 460HR 65 130 8.19 176 1 DNT UTE

-11. 02 UTE UTE 4123 OUTLET 520SI 5.60 174 1 DNT LTE

+11.92 LTE LTE 4130 INLET 460SI 66 2

7.31 18 P 1 DRS UTE

-0.81 UTE UTE SLV 1001 INLET 400PS 66 3

8.28 21 P 1 DRS UTE

-0.80 UTE UTE SLV 1001 INLET 400PS 0.25 56 2

VOL 014

+1.17 014 014 4031 OUTLET 460SI 66 7

1. 65 22 2

TEA UTE

-0.17 UTE UTE 2083 INLET 460HR 0.07 80 2

VOL 013

+1. 44 013 013 4027 INLET 460SI 66 8

0.35 57 P 3 TWD 6 010

+0.35 010 010 WAR 4027 INLET 460SI 66 9

4.34 26 2

TEA UTE

-0.12 UTE UTE 2083 INLET 460HR 66 12 0.30 75 9

PLP 014

+1.15 014 014 4027 INLET 460SI 66 13 5.98 29 2

TEA UTE

-0.16 UTE UTE 2083 INLET 460HR 0.25 45 P 3 TWD 4 008

+0.62 008 008 WAR 4027 INLET 460SI 0.24 70 P 3 TWD 4 008

-0.47 008 008 WAR 4027 INLET 460SI 66 22 2.69 20 2

TEA UTE

-0.14 UTE UTE 2082 INLET 460HR 66 24

1. 33 29 2

VOL UTE

-0.20 UTE UTE 2082 INLET 460HR 66 31 6.45 28 2

TEA UTE

-0.11 UTE UTE 2083 INLET 460HR 66 36 3.13 28 2

TEA UTE

-0.14 UTE UTE 2087 INLET 460HR 66 37 2.61 23 2

TEA UTE

-0.15 UTE UTE 2086 INLET 460HR 66 41 0.83 20 P 1 SVI UTE

-2.76 UTE UTS 2086 INLET 460HR 0.83 20 P 1 TWD 59 UTE

-2.76 UTE UTS 2086 INLET 460HR 66 44 2.40 22 2

TEA UTE

-0.11 UTE UTE 2087 INLET 460HR 66 50 4.96 180 1 DNT 006

+18.05 006 006 4067 INLET 460SI 66 51

1. 90 173 1 DNT UTE

-5.70 UTE UTE 4067 INLET 460SI 66 52 0.42 23 2

TEA UTE

-0.10 UTE UTE 2087 INLET 460HR 66 55 2.56 36 2

TEA UTE

-0.11 UTE UTE 2098 INLET 460HR 66 60 0.87 26 2

TEA UTE

-0.18 UTE UTE 2007 INLET 460HR 66 62

1. 63 17 2

TEA UTE

-0.22 UTE UTE 2003 INLET 460HR 66 69 3.81 30 2

TEA UTE

-0.17 UTE UTE 2003 INLET 460HR 66 70 3.64 20 2

TEA UTE

-0.26 UTE UTE 2004 INLET 460HR

Frarnatome ANP Inc.

05/02/02 13:29:33 Customer Name: Oconee Unit 1 Component: S/G B Page 70 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

66 71 2.03 20 2

TEA UTE

-0.19 UTE UTE 2003 INLET 460HR 8.77 188 1 DNT LTE

+6.00 LTE LTS 4006 OUTLET 460S1 66 76 2.04 23 2

TEA UTE

-0.17 UTE UTE 2073 INLET 460HR 66 79 0.50 19 2

SAl UTE

-3.62 UTE UTS 2068 INLET 460HR 0.50 19 2

TWD 52 UTE

-3.62 UTE UTS 2068 INLET 460HR 66 84 2.40 19 2

TEA UTE

-0.23 UTE UTE 2067 INLET 460HR 66 87 0.11 83 2

SAl 010

-9.26 010 010 4119 OUTLET 520S1 0.34 77 2

SAl 010

-6.56 TO-3.73 010 010 4119 OUTLET 520S1 0.32 78 2

TWD 45 010

-4.82 010 010 4119 OUTLET 520S1 66 88 3.22 23 2

TEA UTE

-0.21 UTE UTE 2067 INLET 460HR 66 89 4.39 25 2

TEA UTE

-0.18 UTE UTE 2068 INLET 460HR 66 90 3.30 21 2

TEA UTE

-0.18 UTE UTE 2067 INLET 460HR 66 91 3.62 25 2

TEA UTE

-0.14 UTE UTE 2068 INLET 460HR 66 93 3.45 18 2

TEA UTE

-0.15 UTE UTE 2068 INLET 460HR 66 97 3.28 19 2

TEA UTE

-0.06 UTE UTE 2068 INLET 460HR 66 101 2.05 17 2

TEA UTE

-0.11 UTE UTE 2068 INLET 460HR 66 103 5.52 28 2

TEA UTE

-0.16 UTE UTE 2068 INLET 460HR 66 106 3.48 22 2

TEA UTE

-0.15 UTE UTE 2067 INLET 460HR 66 108 4.32 25 2

TEA UTE

-0.18 UTE UTE 2067 INLET 460HR 66 114 0.35 54 P 3 TWD 8 007

-0.06 007 007 WAR 4119 OUTLET 520S1 3.24 26 2

TEA UTE

-0.18 UTE UTE 2067 INLET 460HR 66 116 0.54 77 P 3 TWO 11 009

-0.61 009 009 WAR 4120 OUTLET 520S1 0.28 149 2 VOL 007

-0.13 007 007 4130 INLET 460S1 3.29 31 2

TEA UTE

-0.18 UTE UTE 2063 INLET 460HR 66 117 2.85 23 2

TEA UTE

-0.24 UTE UTE 2064 INLET 460HR 66 119 0.47 93 P 3 TWD 9 009

+0.55 009 009 WAR 4120 OUTLET 520S1 2.27 28 2

TEA UTE

-0.19 UTE UTE 2064 INLET 460HR 66 123 0.32 88 P 3 TWD 7 009

+0.48 009 009 WAR 4120 OUTLET 520S1 66 124 4.26 30 2

TEA UTE

-0.24 UTE UTE 2063 INLET 460HR 66 125 5.47 181 1 DNT LTE

+10.90 LTE LTE 4120 OUTLET 520S1 3.03 172 1 DNT UTE

-11.23 UTE UTE 4120 OUTLET 520S1 3.49 33 2

TEA UTE

-0.20 UTE UTE 2063 INLET 460HR 66 126 7.00 180 1 DNT LTE

+11.29 LTE LTE 4120 OUTLET 520S1 7.12 176 1 DNT UTE

-11.20 UTE UTE 4120 OUTLET 520S1 66 130 9.39 185 1 DNT LTE

+11. 68 LTE LTE 4120 OUTLET 520SI 7.25 182 1 DNT UTE

-11. 37 UTE UTE 4120 OUTLET 520SI 4.50 173 1 DNT UTE

-11. 74 UTE UTE 4120 OUTLET 520S1 3.76 173 1 DNT UTE

-12.31 UTE UTE 4120 OUTLET 520S1 3.27 27 2

TEA UTE

-0.21 UTE UTE 2063 INLET 460HR 67 2

5.96 18 P 1 DRS UTE

-0.76 UTE UTE SLV 1001 INLET 400PS 67 6

0.31 78 2

VOL 013

+1.15 013 013 4031 OUTLET 460S1 3.03 17 P 1 DRS UTE

-0.94 UTE UTE SLV 1002 INLET 400PS 67 8

2.12 20 2

TEA UTE

-0.13 UTE UTE 2083 INLET 460HR 67 9

1. 34 22 2

TEA UTE

-0.26 UTE UTE 2082 INLET 460HR 0.44 108 P 3 TWD 7 010

+0.43 010 010 WAR 4027 INLET 460SI 67 12 2.09 29 2

TEA UTE

-0.33 UTE UTE 2082 INLET 460HR 0.41 52 P 3 TWO 6 008

+0.60 008 008 WAR 4027 INLET 460S1 0.42 152 P 3 TWD 6 008

-0.49 008 008 WAR 4027 INLET 460S1 67 13 0.30 46 P 3 TWD 5 003

-0.30 003 003 WAR 4027 INLET 460SI 67 14 0.32 107 P 3 TWD 5 008

+0.45 008 008 WAR 4027 INLET 460S1 67 16 4.73 23 2

TEA UTE

-0.20 UTE UTE 2082 INLET 460HR 67 17

1. 91 22 2

TEA UTE

-0.16 UTE UTE 2083 INLET 460HR 67 18 4.36 179 1 DNT LTS

-11. 73 LTS LTS 4027 INLET 460SI 67 20 2.08 23 2

TEA UTE

-0.17 UTE UTE 2082 INLET 460HR 67 22 1.27 23 2

TEA UTE

-0.24 UTE UTE 2082 INLET 460HR 67 27 0.73 37 2

PVN UTE

-0.09 TO-2.60 UTE UTS 2083 INLET 460HR 67 30 2.86 24 2

TEA UTE

-0.19 UTE UTE 2082 INLET 460HR 67 32 2.14 49 2

TEA UTE

-0.16 UTE UTE 2082 INLET 460HR 67 34 5.34 24 2

TEA UTE

-0.27 UTE UTE 2082 INLET 460HR 0.32 107 2 VOL 007

+0.13 007 007 4027 INLET 460S1 67 38 4.55 176 1 DNT UTS

-10.92 UTS UTS 4063 INLET 460S1 4.65 173 1 DNT UTS

-9.80 UTS UTS 4063 INLET 460S1 2.51 163 1 DNT UTS

-8.69 UTS UTS 4063 INLET 460SI 2.86 174 1 DNT UTS

+0.88 UTS UTS 4063 INLET 460S1 3.44 176 1 DNT UTS

+4.30 UTS UTS 4063 INLET 460S1 3.20 175 1 DNT UTS

+3.14 UTS UTS 4063 INLET 460S1 3.43 166 1 DNT UTS

-20.29 UTS UTS 4063 INLET 460S1 3.43 161 1 DNT UTS

-22.23 UTS UTS 4063 INLET 460SI 4.37 165 1 DNT UTS

-21. 25 UTS UTS 4063 INLET 460SI 67 49

1. 81 20 2

TEA UTE

-0.21 UTE UTE 2083 INLET 460HR 67 53 9.06 186 1 DNT 014

+0.71 014 014 4063 INLET 460S1 67 54 4.03 23 2

TEA UTE

-0.16 UTE UTE 2098 INLET 460HR 67 59 0.08 110 2 SAl LTS

-4.49 LTS LTS 3002 OUTLET 460TS 0.13 118 2 TWD 0 LTS

-4.49 LTS LTS 3002 OUTLET 460TS 67 68 5.78 184 1 DNT UTS

+5.45 UTS UTS 4002 OUTLET 460S1

Framatome ANP Inc.

Customer Name: Oconee Unit 1 05/02/02 13:29:33 Component: S/G B


~---

Page 71 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 68 68 68 68 68 68 68 68 68 68 68 68 68 69 75 76 80 81 84 95 96 97 98 99 108 110 111 113 114 115 116 118 119 121 123 124 126 127 128 129 130 2

5 6

11 12 13 14 22 23 27 29 30 39 6.10 0.78 2.20 3.01 3.26 1.29 0.10 1.09 4.23 3.88 3.25 4.27 3.23 3.99

1. 49
1. 49 0.29 0.36 6.32 2.67 6.14 1.24 0.81 0.11 0.39 0.25 0.16 0.41 0.28 0.21 3.23 9.07 8.74 8.43 7.52 5.32 9.72 7.83 7.93 7.80 3.21 3.01 0.32 0.15 3.24 6.39 6.18 6.99 7.05 3.67 13.84 8.05 0.54
1. 03 0.77 2.07 5.53
1. 04 0.31 0.36 0.51
1. 78 0.20 0.46 0.25 0.33 3.30 2.10 3.12 3.58 4.20
1. 70 2.78 3.71 3.25 22 80 21 25 27 27 96 25 23 19 23 28 21 24 28 28 80 97 24 24 26 30 65 56 97 60 87 81 101 86 29 178 2

TEA 1

VOL 2

TEA 2

TEA 2

TEA 2

TEA 2

VOL 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

SAl 2

TWD 85 P 3 TWD 6 P 3 TWD 7 2

TEA 2

TEA 2

TEA 2

TEA P 3 TWD 15 2

VOL P 3 TWD 8 2

VOL 2

VOL P 3 TWD 9 P 3 TWD 6 2

VOL 2

TEA 1

DNT 178 1 179 1 179 1 24 2

175 1 176 1 179 1 178 1 23 2

25 2

57 P 3 62 2

25 2

181 1 178 1 183 1 181 1 22 2

179 1 177 1 DNT DNT DNT TEA DNT DNT DNT DNT TEA TEA TWD 7 VOL TEA DNT DNT DNT DNT TEA DNT DNT o

39 39 35 22 22 41 94 99 29 53 24 P 3 TWD 10 P 1 VOL P 3 TWD 13 P 1 DRS P 1 DRS 1

DRS P 3 TWD 2 P 3 TWD 2 P 3 TWD 8 2

2 2

56 P

52 P

25 2

6 1

25 2

23 2

20 2

180 1 180 1 180 1 183 1 TEA VOL TEA 3 TWD 4 3 TWD 5 TEA DNT TEA TEA TEA DNT DNT DNT DNT UTE 015 UTE UTE UTE UTE 013 UTE UTE UTE UTE UTE UTE UTE UTE UTE 008 008 UTE UTE UTE UTE 010 014 008 011 014 008 009 014 UTE LTE LTE UTE UTE UTE LTE LTE UTE UTE UTE UTE 010 012 UTE LTE LTE UTE UTE UTE LTE LTE 012 UTE 010 UTE UTE UTE 009 009 008 UTE 014 UTE 009 008 UTE LTE UTE UTE UTE UTS UTS UTS UTS

-0.11

+11.66

-0.37

-0.17

-0.14

-0.07

+5.44

-0.20

-0.16

-0.16

-0.14

-0.24

-0.11

-0.19

-3.73

-3.73

-0.18

-0.36

-0.18

-0.06

-0.18

-0.17

-0.61

+1.70

-0.67

-0.70

+0.93

-0.44

+0.37

+0.80

-0.26

+10.73

+9.44

-8.86

-11. 27

-0.19

+11.16

+9.39

-8.38

-10.58

-0.14

-0.23

-0.51

+0.75

-0.10

+11.07

+11. 30

-11. 06

-11. 38

-0.16

+2.93

+5.50

+0.78

-0.45

+0.69

-0.80

-0.48

-0.88

+0.01

-0.74

+0.61

-0.18

+1. 40

-0.16

-0.66

-0.43

-0.14

+4.16

-0.18

-0.17

-0.20

+6.41

+7.53

+8.71

+9.81 EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE UTE UTE 015 015 UTE UTE UTE UTE UTE UTE UTE UTE 013 013 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS TR UTE UTS 008 008 WAR 008 008 WAR UTE UTE UTE UTE UTE UTE UTE UTE 010 010 WAR 014 014 008 008 WAR 011 011 014 014 008 008 WAR 009 009 WAR 014 014 UTE UTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE 010 010 WAR 012 012 UTE UTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE 012 012 WAR UTE UTE SLV 010 010 WAR UTE UTE SLV UTE UTE SLV UTE UTE SLV 009 009 WAR 009 009 WAR 008 008 WAR UTE UTE 014 014 UTE UTE 009 009 WAR 008 008 WAR UTE UTE LTE LTE UTE UTE UTE UTE UTE UTE UTS UTS UTS UTS UTS UTS UTS UTS 2003 4002 2004 2073 2108 2067 4124 2067 2068 2067 2068 2067 2068 2067 2067 2067 4120 4120 2067 2068 2067 2067 4120 4120 4120 4120 4120 4120 4120 4120 2067 4120 4120 4120 4120 2067 4120 4120 4120 4120 2068 2067 4120 4120 2068 4120 4120 4120 4120 2068 4031 4031 4031 1002 4031 1002 1008 1002 4027 4027 4027 2083 4027 2082 4027 4027 2082 4027 2083 2083 2082 4063 4063 4063 4063

===

INLET OUTLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET 460HR 460SI 460HR 460HR 460HR 460HR 520SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 520SI 520SI 460HR 460HR 460HR 460HR 520SI 520SI 520SI 520SI 520SI 520SI 520SI 520SI 460HR 520SI 520SI 520SI 520SI 460HR 520SI 520SI 520SI 520SI 460HR 460HR 520SI 520SI 460HR 520SI 520SI 520SI 520SI 460HR 460SI 460SI 460S1 400PS 460S1 400PS 400PS 400PS 460SI 460SI 460SI 460HR 460SI 460HR 460SI 460S1 460HR 460SI 460HR 460HR 460HR 460S1 460S1 460S1 460S1

Framatome ANP Inc.

05/02/02 13:29:34 Customer Name: Oconee Unit 1 Component: S/G B Page 72 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS., MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

2.79 26 2

TEA UTE

-0.13 UTE UTE 2083 INLET 460HR 68 49 0.32 53 P 3 TWO 4 007

-0.14 007 007 WAR 4020 INLET 460SI 68 55 3.59 22 2

TEA UTE

-0.13 UTE UTE 2099 INLET 460HR 68 61 3.68 22 2

TEA UTE

-0.18 UTE UTE 2007 INLET 460HR 68 62 1.39 20 2

MAl UTE

-2.38 UTE UTS TR 2003 INLET 460HR 0.89 27 2

TWO 81 UTE

-2.38 UTE UTS TR 2003 INLET 460HR 1.39 20 2

TWO 57 UTE

-2.38 UTE UTS TR 2003 INLET 460HR 1.21 14 2

TWO 37 UTE

-2.38 UTE UTS TR 2003 INLET 460HR 68 65 1.63 16 2

TEA UTE

-0.18 UTE UTE 2004 INLET 460HR 0.38 52 2

TWO 92 UTE

-1. 4 4 UTE UTE 2004 INLET 460HR 0.43 57 2

SVI UTE

-1. 44 UTE UTE CS 2004 INLET 460HR 5.13 176 1 ONT LTE

+11.31 LTE LTS 4006 OUTLET 460SI 68 67 3.22 18 2

TEA UTE

-0.18 UTE UTE 2004 INLET 460HR 68 69 3.49 23 2

TEA UTE

-0.28 UTE UTE 2014 INLET 460HR 68 75 4.02 24 2

TEA UTE

-0.25 UTE UTE 2004 INLET 460HR 68 82 4.79 21 2

TEA UTE

-0.15 UTE UTE 2067 INLET 460HR 68 84 9.07 21 2

TEA UTE

-0.14 UTE UTE 2067 INLET 460HR 68 94 0.72 10 2

TEA UTE

-0.04 UTE UTE 2067 INLET 460HR 68 97 0.93 27 P 1 SCI UTE

-0.21 UTE UTS CL 2068 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.21 TO+58.5 UTE UTS 2068 INLET 460HR 0.12 70 P 3 TWO 14 UTE

-0.21 TO+67.5 UTE UTS 2068 INLET 460HR 0.50 38 P 3 TWO 59 UTE

-0.21 TO+76.5 UTE UTS 2068 INLET 460HR 0.76 33 P 3 TWO 89 UTE

-0.21 TO+85.5 UTE UTS 2068 INLET 460HR 0.80 27 P 3 TWO 94 UTE

-0.21 TO+94.5 UTE UTS 2068 INLET 460HR 0.64 25 P 3 TWO 75 UTE

-0.21 TO+103.5 UTE UTS 2068 INLET 460HR 0.32 35 P 3 TWO 38 UTE

-0.21 TO+112.5 UTE UTS 2068 INLET 460HR 0.53 31 P 3 TWO 62 UTE

-0.21 TO+121. 5 UTE UTS 2068 INLET 460HR 0.81 28 P 3 TWO 95 UTE

-0.21 TO+130.5 UTE UTS 2068 INLET 460HR 0.40 33 P 3 TWO 48 UTE

-0.21 TO+139.5 UTE UTS 2068 INLET 460HR 0.12 38 P 3 TWO 14 UTE

-0.21 TO+148.5 UTE UTS 2068 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.21 TO+157.5 UTE UTS 2068 INLET 460HR 68 99 1.87 23 2

TEA UTE

-0.09 UTE UTE 2068 INLET 460HR 68 100 5.78 24 2

TEA UTE

-0.11 UTE UTE 2067 INLET 460HR 68 101 1.58 24 2

TEA UTE

-0.08 UTE UTE 2068 INLET 460HR 68 102 1.37 30 2

TEA UTE

-0.10 UTE UTE 2067 INLET 460HR 68 103 3.30 28 2

TEA UTE

-0.08 UTE UTE 2068 INLET 460HR 68 104

1. 95 12 P 1 SCI UTE

-0.37 UTE UTS CL 2067 INLET 460HR 0.52 5

P 3 TWO 0 UTE

-0.37 TO+351. 2 UTE UTS 2067 INLET 460HR 0.38 10 P 3 TWO 23 UTE

-0.37 TO+342.4 UTE UTS 2067 INLET 460HR 1.05 17 P 3 TWO 39 UTE

-0.37 TO+333.7 UTE UTS 2067 INLET 460HR 1.28 16 P 3 TWO 43 UTE

-0.37 TO+324.9 UTE UTS 2067 INLET 460HR 0.76 24 P 3 TWO 33 UTE

-0.37 TO+316.1 UTE UTS 2067 INLET 460HR 0.22 25 P 3 TWO 17 UTE

-0.37 TO+307.3 UTE UTS 2067 INLET 460HR 0.71 179 P 3 TWO 0 UTE

-0.37 TO+298.5 UTE-UTS 2067 INLET 460HR 68 108 3.23 20 2

TEA UTE

-0.18 UTE UTE 2067 INLET 460HR 68 109 4.24 29 2

TEA UTE

-0.05 UTE UTE 2068 INLET 460HR 68 111 2.11 23 2

TEA UTE

-0.19 UTE UTE 2067 INLET 460HR 68 113 5.47 24 2

TEA UTE

-0.11 UTE UTE 2068 INLET 460HR 68 115 2.72 18 2

TEA UTE

-0.23 UTE UTE 2067 INLET 460HR 68 117 4.53 28 2

TEA UTE

-0.15 UTE UTE 2067 INLET 460HR 68 120 2.22 21 2

TEA UTE

-0.16 UTE UTE 2067 INLET 460HR 68 122 0.75 88 P 3 TWO 14 014

+0.70 014 014 WAR 4123 OUTLET 520SI 4.88 28 2

TEA UTE

-0.12 UTE UTE 2068 INLET 460HR 68 124 0.45 89 P 3 TWO 8 008

-0.72 008 008 WAR 4123 OUTLET 520S1 4.09 24 2

TEA UTE

-0.22 UTE UTE 2067 INLET 460HR 68 126 5.28 176 1 ONT LTE

+9.64 LTE LTE 4120 OUTLET 520S1 0.57 76 2

VOL 014

+0.55 014 014 4120 OUTLET 520S1 8.37 175 1 ONT UTE

-8.67 UTE UTE 4120 OUTLET 520SI 2.22 19 2

TEA UTE

-0.18 UTE UTE 2067 INLET 460HR 68 128 8.94 175 1 DNT LTE

+9.52 LTE LTE 4120 OUTLET 520S1 8.28 177 1 DNT LTE

+10.50 LTE LTE 4120 OUTLET 520S1 10.17 174 1 DNT UTE

-8.73 UTE UTE 4120 OUTLET 520SI 9.51 174 1 DNT UTE

-10.60 UTE UTE 4120 OUTLET 520SI 3.81 23 2

TEA UTE

-0.21 UTE UTE 2067 INLET 460HR 68 129 0.06 73 2

VOL 012

+1.10 012 012 4121 OUTLET 520SI 0.36 78 2

VOL 014

+1. 43 014 014 4121 OUTLET 520SI

1. 46 23 2

TEA UTE

-0.20 UTE UTE 2067 INLET 460HR 68 130 10.27 179 1 ONT LTE

+10.73 LTE LTE 4123 OUTLET 520SI 8.91 177 1 ONT UTE

-09.94 UTE UTE 4123 OUTLET 520SI

1. 81 21 2

TEA UTE

-0.19 UTE UTE 2068 INLET 460HR 69 7

5.38 20 P 1 DRS UTE

-0.72 UTE UTE SLV 1002 INLET 400PS 69 8

3.68 22 P 1 DRS UTE

-0.66 UTE UTE SLV 1002 INLET 400P5 69 9

0.17 55 2

VOL 014

+1.14 014 014 4031 OUTLET 46051

4. OS 22 p 1 DRS UTE

-0.64 UTE UTE SLV 1002 INLET 400PS 69 12 0.10 57 2

VOL 014

+1.16 014 014 4027 INLET 460S1

Framatome ANP Inc.

05/02/02 13:29:35 Customer Name: Oconee Unit 1 Component: S/G B Page 73 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS.,. MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

69 15 0.10 92 2

VOL 013

+2.15 014 013 4020 INLET 460SI 0.28 87 P 3 TWD 3 008

+0.72 009 008 WAR 4020 INLET 460SI 69 23 0.63 21 2

TEA UTE

-0.22 UTE UTE 2082 INLET 460HR 69 24

1. 23 16 2

TEA UTE

-0.16 UTE UTE 2083 INLET 460HR 69 28 1.13 24 2

TEA UTE

-0.15 UTE UTE 2083 INLET 460HR 69 29

1. 69 14 2

TEA UTE

-0.14 UTE UTE 2082 INLET 460HR 69 33

1. 08 27 2

TEA UTE

-0.21 UTE UTE 2082 INLET 460HR 69 34 0.37 96 P 3 TWD 4 007

+0.52 008 007 WAR 4020 INLET 460SI 69 45 1.72 17 2

TEA UTE

-0.15 UTE UTE 2082 INLET 460HR 0.19 110 2 VOL LTS

+11.85 015 LTS 4020 INLET 460SI 69 47

1. 91 20 2

TEA UTE

-0.21 UTE UTE 2082 INLET 460HR 69 53 2.32 20 2

TEA UTE

-0.12 UTE UTE 2082 INLET 460HR 69 62 3.23 24 2

TEA UTE

-0.25 UTE UTE 2004 INLET 460HR 69 63 2.23 21 2

TEA UTE

-0.21 UTE UTE 2003 INLET 460HR 69 65 3.74 171 1 DNT LTE

+6.87 LTE LTE 4002 OUTLET 460SI 2.53 357 1 DNT LTE

+7.72 LTE LTS 4007 OUTLET 460SI 69 69 3.02 23 2

TEA UTE

-0.34 UTE UTE 2003 INLET 460HR 69 76 2.50 15 2

TEA UTE

-0.32 UTE UTE 2004 INLET 460HR 69 77 2.79 22 2

TEA UTE

-0.19 UTE UTE 2067 INLET 460HR 69 80 5.96 24 2

TEA UTE

-0.13 UTE UTE 2068 INLET 460HR 69 81 2.31 32 2

TEA UTE

-0.20 UTE UTE 2067 INLET 460HR 69 82 2.01 21 2

TEA UTE

-0.08 UTE UTE 2068 INLET 460HR 69 83 3.72 17 2

TEA UTE

-0.10 UTE UTE 2067 INLET 460HR 69 84 2.61 21 2

TEA UTE

-0.13 UTE UTE 2068 INLET 460HR 69 85 7.66 23 2

TEA UTE

-0.13 UTE UTE 2067 INLET 460HR 69 86 1.46 18 2

TEA UTE

-0.12 UTE UTE 2068 INLET 460HR 69 89 1.65 20 2

TEA UTE

-0.11 UTE UTE 2068 INLET 460HR 69 93 8.13 21 2

TEA UTE

-0.11 UTE UTE 2068 INLET 460HR 69 97 3.84 19 2

TEA UTE

-0.09 UTE UTE 2068 INLET 460HR 69 100 2.24 19 2

TEA UTE

-0.14 UTE UTE 2067 INLET 460HR 69 101

1. 49 35 2

TEA UTE

-0.10 UTE UTE 2068 INLET 460HR 69 108 2.95 21 2

TEA UTE

-0.21 UTE UTE 2067 INLET 460HR 69 110 4.69 28 2

TEA UTE

-0.15 UTE UTE 2067 INLET 460HR 69 113 0.91 11 2

TEA UTE

-0.10 UTE UTE 2068 INLET 460HR 69 115 4.08 23 2

TEA UTE

-0.15 UTE UTE 2068 INLET 460HR 69 118 0.32 25 2

VOL 014

+0.93 014 014 4121 OUTLET 520SI 69 120 6.62 24 2

TEA UTE

-0.16 UTE UTE 2067 INLET 460HR 69 122 0.32 94 P 3 TWD 6 009

-0.66 009 009 WAR 4121 OUTLET 520SI 0.16 125 2 VOL 014

+0.89 014 014 4121 OUTLET 520SI 2.32 26 2

TEA UTE

-0.21 UTE UTE 2067 INLET 460HR 69 124 5.18 160 1 DNT LTE

+11.10 LTE LTE 4121 OUTLET 520SI 0.50 92 P 3 TWD 9 007

-0.73 007 007 WAR 4121 OUTLET 520SI 0.20 101 2 VOL 014

+0.94 014 014 4121 OUTLET 520SI 8.16 177 1 DNT UTE

-10.42 UTE UTE 4121 OUTLET 520SI 2.23 31 2

TEA UTE

-0.18 UTE UTE 2067 INLET 460HR 69 125 0.12 77 2

VOL 014

+1. 07 014 014 4121 OUTLET 520SI 2.70 21 2

TEA UTE

-0.11 UTE UTE 2068 INLET 460HR 69 126 0.17 63 2

VOL 014

+1.06 014 014 4121 OUTLET 520SI 0.16 51 2

VOL 014

+1.17 014 014 4121 OUTLET 520SI

1. 25 29 2

TEA UTE

-0.22 UTE UTE 2067 INLET 460HR 69 127 9.12 178 1 DNT LTE

+10.47 LTE LTE 4121 OUTLET 520SI 6.73 171 1 DNT UTE

-8.60 UTE UTE 4121 OUTLET 520SI 6.06 170 1 DNT UTE

-10.57 UTE UTE 4121 OUTLET 520SI 3.94 23 2

TEA UTE

-0.13 UTE UTE 2068 INLET 460HR 69 129 8.92 178 1 DNT UTE

-10.45 UTE UTE 4121 OUTLET 520SI 6.09 172 1 DNT LTE

+11. 77 LTE LTE 4130 INLET 460SI 2.14 170 1 DNT LTE

+10.41 LTE LTE 4130 INLET 460SI

1. 75 33 2

TEA UTE

-0.23 UTE UTE 2067 INLET 460HR 69 130 0.27 87 2

VOL 014

+0.76 014 014 4121 OUTLET 520SI 3.24 27 2

TEA UTE

-0.14 UTE UTE 2068 INLET 460HR 69 131 8.12 177 1 DNT LTE

+11. 09 LTE LTE 4121 OUTLET 520SI 0.12 127 2 VOL 010

+0.52 010 010 4121 OUTLET 520SI 5.76 179 1 DNT UTE

-10.28 UTE UTE 4121 OUTLET 520SI

1. 82 26 2

TEA UTE

-0.13 UTE UTE 2068 INLET 460HR 70 2

4.70 184 1 DNT LTE

+2.53 LTE LTE 4031 OUTLET 460SI 5.51 182 1 DNT LTE

+5.77 LTE LTE 4031 OUTLET 460SI 6.59 181 1 DNT LTE

+10.78 LTE LTE 4031 OUTLET 460SI 70 7

6.84 18 P 2 DRS UTE

-0.77 UTE UTE SLV 1003 INLET 400PS 70 8

5.53 18 P 1 DRS UTE

-0.76 UTE UTE SLV 1002 INLET 400PS 70 9

2.82 32 P 1 DRS UTE

-0.70 UTE UTE SLV 1002 INLET 400PS 70 10 2.28 24 2

TEA UTE

-0.13 UTE UTE 2083 INLET 460HR 5.41 177 1 DNT UTS

-0.55 UTS UTS 4027 INLET 460SI 0.09 94 2

VOL 014

+1.19 014 014 4027 INLET 460SI 6.73 176 1 DNT UTS

-0.66 UTS UTS 904 INLET 460LW 70 12

1. 75 21 2

TEA UTE

-0.16 UTE UTE 2083 INLET 460HR

Framatome ANP Inc.

05/02/02 13:29:36 Customer Name: Oconee Unit 1 Component: S/G B Page 74 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS.,. MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

70 13 3.34 27 2

TEA UTE

-0.20 UTE UTE 2082 INLET 460HR 70 14 0.95 71 P 3 TWD 8 008

+0.74 008 008 WAR 4027 INLET 460SI 70 15 0.35 85 2

VOL 013

+0.64 013 013 4027 INLET 460S1 70 16 3.79 28 2

TEA UTE

-0.15 UTE UTE 2083 INLET 460HR 70 17

1. 50 86 1

VOL 010

+12.45 010 010 4027 INLET 460S1 0.40 79 P 3 TWD 3 008

+0.76 008 008 WAR 4027 INLET 460SI 70 18 0.40 48 P 3 TWD 4 008

+0.81 009 008 WAR 4020 INLET 460SI 70 23

1. 98 18 2

TEA UTE

-0.12 UTE UTE 2082 INLET 460HR 0.85 71 P 3 TWD 9 010

-0.67 010 010 WAR 4020 INLET 460SI 70 24

1. 04 13 2

TEA UTE

-0.15 UTE UTE 2083 INLET 460HR 70 25

1. 42 178 1 DNT LTS

+37.67 001 LTS 4020 INLET 460SI

1. 37 185 1 DNT LTS

+36.69 001 LTS 4020 INLET 460SI 2.49 177 1 DNT LTS

+19.42 001 LTS 4020 INLET 460SI 2.28 188 1 DNT LTS

+18.58 001 LTS 4020 INLET 460SI 70 31 7.00 175 1 DNT 011

+11. 85 012 011 4020 INLET 460SI 70 35 7.50 25 2

TEA UTE

-0.15 UTE UTE 2082 INLET 460HR 70 38 2.97 25 2

TEA UTE

-0.15 UTE UTE 2083 INLET 460HR 70 40 2.86 23 2

TEA UTE

-0.19 UTE UTE 2083 INLET 460HR 70 48 2.27 20 2

TEA UTE

-0.29 UTE UTE 2126 INLET 460HR 70 50

1. 23 26 2

TEA UTE

-0.22 UTE UTE 2083 INLET 460HR 70 54 4.07 185 1 DNT LTS

+16.40 001 LTS 4020 INLET 460SI

1. 06 102 1 VOL LTS

+15.91 001 LTS 4020 INLET 460SI 70 58

1. 65 175 1 DNT 009

+10.54 009 009 4072 INLET 460SI 70 59

1. 82 23 2

TEA UTE

-0.21 UTE UTE 2098 INLET 460HR 70 60 0.17 75 2

VOL 015

+7.43 015 015 4002 OUTLET 460S1 70 65 2.53 175 1 DNT LTS

+2.73 LTS LTS 4002 OUTLET 460S1 3.77 177 1 DNT LTS

+3.68 LTS LTS 4002 OUTLET 460SI 4.15 23 2

TEA UTE

-0.19 UTE UTE 2003 INLET 460HR 2.69 345 1 DNT LTS

+4.68 LTE 001 4007 OUTLET 460SI 70 68 2.50 17 2

TEA UTE

-0.24 UTE UTE 2004 INLET 460HR 70 73 3.44 26 2

TEA UTE

-0.18 UTE UTS 2003 INLET 460HR 2.90 21 2

TEA UTE

-0.27 UTE UTS 2014 INLET 460HR 70 75 2.00 176 1 DNT UTS

+9.28 UTS UTS 4002 OUTLET 460SI 70 77 3.32 19 2

TEA UTE

-0.17 UTE UTE 2067 INLET 460HR 70 80 4.33 27 2

TEA UTE

-0.14 UTE UTE 2068 INLET 460HR 70 89 8.80 22 2

TEA UTE

-0.17 UTE UTE 2068 INLET 460HR 70 90 7.42 23 2

TEA UTE

-0.21 UTE UTE 2067 INLET 460HR 70 96 5.20 28 2

TEA UTE

-0.23 UTE UTE 2108 INLET 460HR 70 97 4.67 28 2

TEA UTE

-0.11 UTE UTE 2068 INLET 460HR 70 100 4.85 26 2

TEA UTE

-0.13 UTE UTE 2067 INLET 460HR 70 101 6.37 26 2

TEA UTE

-0.13 UTE UTE 2068 INLET 460HR 70 104 2.52 25 2

TEA UTE

-0.19 UTE UTE 2067 INLET 460HR 70 106 5.15 26 2

TEA UTE

-0.18 UTE UTE 2067 INLET 460HR 70 107 12.48 178 1 DNT 007

-3.34 007 007 4121 OUTLET 520SI 70 111 0.22 65 P 3 TWD 4 007

-0.17 007 007 WAR 4121 OUTLET 520SI 70 113 6.30 26 2

TEA UTE

-0.16 UTE UTE 2068 INLET 460HR 70 114 3.90 20 2

TEA UTE

-0.19 UTE UTE 2067 INLET 460HR 70 115 3.52 20 2

TEA UTE

-0.16 UTE UTE 2068 INLET 460HR 70 116 5.04 23 2

TEA UTE

-0.20 UTE UTE 2067 INLET 460HR 70 119 0.43 96 P 3 TWD 8 008

-0.61 008 008 WAR 4121 OUTLET 520S1 0.90 26 2

TEA UTE

-0.17 UTE UTE 2067 INLET 460HR 70 120 4.14 26 2

TEA UTE

-0.23 UTE UTE 2067 INLET 460HR 70 121 7.80 26 2

TEA UTE

-0.18 UTE UTE 2068 INLET 460HR 70 124 9.15 176 1 DNT LTE

+11. 03 LTE LTE 4121 OUTLET 520SI 7.98 176 1 DNT UTE

-10.59 UTE UTE 4121 OUTLET 520SI 0.62 144 P 3 TWD 8 008

-0.75 008 008 WAR 4130 INLET 460SI 5.17 21 2

TEA UTE

-0.14 UTE UTE 2067 INLET 460HR 70 125 0.12 59 2

VOL 014

+1. 31 014 014 4121 OUTLET 520SI 1.19 21 2

TEA UTE

-0.09 UTE UTE 2067 INLET 460HR 70 126 0.63 43 2

VOL 014

+0.56 014 014 4121 OUTLET 520SI 70 128 5.54 165 1 DNT LTE

+10.51 LTE LTE 4121 OUTLET 520SI 9.72 176 1 DNT UTE

-10.57 UTE UTE 4121 OUTLET 520SI 70 130 0.12 67 2

VOL 013

+0.78 013 013 4121 OUTLET 520S1 2.89 21 2

TEA UTE

-0.24 UTE UTE 2067 INLET 460HR 71 2

5.87 180 1 DNT LTE

+11.22 LTE LTE 4031 OUTLET 460SI 0.29 113 2 VOL 012

+1. 26 012 012 4031 OUTLET 460SI 71 7

0.68 0

P 3 TWD 13 008

+0.71 008 008 WAR 4031 OUTLET 460S1 71 8

7.71 164 1 DNT LTE

+11. 64 LTE LTE 4031 OUTLET 460SI 5.82 18 P 1 DRS UTE

-0.65 UTE UTE SLV 1003 INLET 400PS 71 9

3.00 172 1 DNT LTE

+11. 76 LTE LTE 4031 OUTLET 460SI 71 12

1. 32 19 2

TEA UTE

-0.10 UTE UTE 2083 INLET 460HR 71 14 3.61 24 2

TEA UTE

-0.16 UTE UTE 2083 INLET 460HR 71 18 1.26 29 2

TEA UTE

-0.15 UTE UTE 2083 INLET 460HR 71 24 1.37 24 2

TEA UTE

-0.14 UTE UTE 2082 INLET 460HR 71 25 1.72 25 2

TEA UTE

-0.13 UTE UTE 2083 INLET 460HR

Framatome ANP Inc.

05/02/02 13:29:36 Customer Name: Oconee Unit 1 Component: S/G B Page 75 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -:- MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

71 30 1.85 16 2

TEA UTE

-0.15 UTE UTE 2082 INLET 460HR 71 32 1.18 18 2

TEA UTE

-0.13 UTE UTE 2082 INLET 460HR 71 39 2.56 18 2

TEA UTE

-0.17 UTE UTE 2082 INLET 460HR 71 44

1. 51 9

2 TEA UTE

-0.15 UTE UTE 2083 INLET 460HR 71 45 2.66 198 2 TEA UTE

-0.11 UTE UTE 2082 INLET 460HR 71 48 0.45 76 P 3 TWD 5 010

-0.56 010 009 WAR 4020 INLET 460S1 71 49

1. 54 22 2

TEA UTE

-0.15 UTE UTE 2082 INLET 460HR 71 59 0.43 140 1 VOL 006

-10.92 006 006 4072 INLET 460S1 71 60 2.32 20 2

TEA UTE

-0.16 UTE UTE 2007 INLET 460HR 71 65 3.72 20 2

TEA UTE

-0.27 UTE UTE 2004 INLET 460HR 71 68 3.46 26 2

TEA UTE

-0.23 UTE UTE 2003 INLET 460HR 4.40 183 1 DNT LTE

+1l.91 LTE LTS 4006 OUTLET 460S1 71 69 4.22 181 1 DNT LTE

+11. 07 LTE LTE 4002 OUTLET 460S1 1.56 17 2

TEA UTE

-0.24 UTE UTE 2004 INLET 460HR 71 71 5.93 185 1 DNT LTE

+9.39 LTE LTS 4006 OUTLET 460S1 71 74 4.18 30 2

TEA UTE

-0.19 UTE UTE 2003 INLET 460HR 71 75 5.25 28 2

TEA UTE

-0.21 UTE UTE 2004 INLET 460HR 71 76 5.08 30 2

TEA UTE

-0.29 UTE UTE 2003 INLET 460HR 71 77 7.04 27 2

TEA UTE

-0.17 UTE UTE 2067 INLET 460HR 71 78 4.23 172 1 DNT LTE

+8.61 LTE LTE 4124 OUTLET 520SI 4.63 171 1 DNT LTE

+9.18 LTE LTE 4124 OUTLET 520SI 3.61 169 1 DNT LTE

+9.69 LTE LTE 4124 OUTLET 520SI 71 83 6.59 25 2

TEA UTE

-0.17 UTE UTE 2067 INLET 460HR 71 84 6.32 25 2

TEA UTE

-0.07 UTE UTE 2068 INLET 460HR 71 86 0.97 21 2

MAl UTE

-3.67 UTE UTS 2068 INLET 460HR 0.97 21 2

TWD 57 UTE

-3.67 UTE UTS 2068 INLET 460HR 71 92 2.71 22 2

TEA UTE

-0.14 UTE UTE 2068 INLET 460HR 71 93 4.71 22 2

TEA UTE

-0.16 UTE UTE 2067 INLET 460HR 71 94 2.34 23 2

TEA UTE

-0.19 UTE UTE 2068 INLET 460HR 71 95 2.18 21 2

TEA UTE

-0.16 UTE UTE 2067 INLET 460HR 71 96 7.44 25 2

TEA UTE

-0.19 UTE UTE 2068 INLET 460HR 71 98 7.83 24 2

TEA UTE

-0.14 UTE UTE 2068 INLET 460HR 71 100 0.44 28 P 1 SCI UTE

-3.71 UTE UTS 2068 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-3.71 TO+346.5 UTE UTS 2068 INLET 460HR 0.14 35 P 3 TWD 23 UTE

-3.71 TO+355.5 UTE UTS 2068 INLET 460HR 0.38 21 P 3 TWD 64 UTE

-3.71 TO+4.5 UTE UTS 2068 INLET 460HR 0.40 22 P 3 TWD 68 UTE

-3.71 TO+13.5 UTE UTS 2068 INLET 460HR 0.38 16 P 3 TWD 64 UTE

-3.71 TO+22.5 UTE UTS 2068 INLET 460HR 0.32 12 P 3 TWD 55 UTE

-3.71 TO+31. 5 UTE UTS 2068 INLET 460HR 0.27 18 P 3 TWD 46 UTE

-3.71 TO+40.5 UTE UTS 2068 INLET 460HR 0.11 12 P 3 TWD 19 UTE

-3.71 TO+49.5 UTE UTS 2068 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-3.71 TO+58.5 UTE UTS 2068 INLET 460HR 71 101 2.84 32 2

TEA UTE

-0.20 UTE UTE 2067 INLET 460HR 71 104 3.43 29 2

TEA UTE

-0.23 UTE UTE 2068 INLET 460HR 71 105 3.44 33 2

TEA UTE

-0.15 UTE UTE 2067 INLET 460HR 71 106 6.15 26 2

TEA UTE

-0.08 UTE UTE 2068 INLET 460HR 71 107 6.25 25 2

TEA UTE

-0.22 UTE UTE 2067 INLET 460HR 71 110 7.32 29 2

TEA UTE

-0.16 UTE UTE 2108 INLET 460HR 71 III 5.85 28 2

TEA UTE

-0.14 UTE UTE 2067 INLET 460HR 71 ll2 3.54 26 2

TEA UTE

-0.18 UTE UTE 2068 INLET 460HR 71 113 5.18 23 2

TEA UTE

-0.17 UTE UTE 2067 INLET 460HR 71 116 0.33 48 2

VOL 014

+0.74 014 014 4122 OUTLET 520SI 71 118 5.99 21 2

TEA UTE

-0.15 UTE UTE 2068 INLET 460HR 71 119 0.57 193 1 DNT UTS

-0.92 UTS UTS 4122 OUTLET 520SI 2.73 31 2

TEA UTE

-0.14 UTE UTE 2067 INLET 460HR 71 121 0.16 72 2

VOL 014

+1.01 014 014 4122 OUTLET 520S1 0.16 86 2

VOL 014

+1.16 014 014 4122 OUTLET 520SI 2.80 24 2

TEA UTE

-0.16 UTE UTE 2067 INLET 460HR 71 123 10.53 170 1 DNT LTE

+10.94 LTE LTE 4121 OUTLET 520SI 0.58 122 P 3 TWD 10 008

-0.65 008 008 WAR 4121 OUTLET 520SI 10.13 177 1 DNT UTE

-10.85 UTE UTE 4121 OUTLET 520SI 6.80 24 2

TEA UTE

-0.14 UTE UTE 2067 INLET 460HR 71 124 0.39 51 2

VOL 014

+1. 40 014 014 4121 OUTLET 520SI 2.54 24 2

TEA UTE

-0.10 UTE UTE 2068 INLET 460HR 71 127 0.16 57 2

VOL 014

+1. 09 014 014 4121 OUTLET 520SI 3.08 168 1 DNT UTS

+1l.81 UTS UTS 4130 INLET 460SI 6.11 171 1 DNT LTE

+12.41 LTE LTE 4130 INLET 460SI 3.23 31 2

TEA UTE

-0.13 UTE UTE 2073 INLET 460HR 71 129 0.09 59 2

VOL 014

+1.14 014 014 4121 OUTLET 520SI

1. 49 18 2

TEA UTE

-0.18 UTE UTE 2073 INLET 460HR 71 130 3.16 38 2

TEA UTE

-0.22 UTE UTE 2074 INLET 460HR 72 2

5.50 7

P 1 DRS UTE

-0.56 UTE UTE SLV 1003 INLET 400PS 72 4

0.25 72 2

VOL 013

+0.78 013 013 4031 OUTLET 460SI 4.58 26 P 1 DRS UTE

-0.76 UTE UTE SLV 1008 INLET 400PS 6.15 32 2

DRS UTE

-0.74 UTE UTE SLY 1003 INLET 400PS

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 6

7 10 11 12 13 18 21 22 24 37 39 41 46 47 49 52 53 55 61 63 64 67 68 0.70 8.33 7.07 7.76 2.58 2.26 4.35

1. 30 3.17 5.20 0.09
1. 79 2.17 4.63 3.41 2.72 0.45 0.51 2.28 1.15 2.35 4.69 0.46 2.95 2.48 0.20 2.98 0.39 0.39 0.54 3.41
1. 62 0.11 3.69 3.75 6.60 2.95 3.20 8.18 16.18 0.00 7.11 7.42 7.61 7.62 8.30 9.63 10.17
11. 76 11.52 12.20 13.24 14.45 15.82 17.83 20.62 20.66 19.14 19.74 20.26 17.61 16.78 14.91 13.62 12.08 10.79 9.16 8.21 7.36 0.00 15.79 0.00 4.14 5.88 7.31 o

21 185 18 P 3 TWD 13 P 1 DRS 1

DNT P 1 DRS 21 P 3 DRS P 1 DRS 1

DNT 21 178 27 P

23 2

25 2

59 2

25 2

24 2

22 2

204 2 21 2

44 2

36 2

176 1 19 2

22 2

27 2

105 25 1 DRS TEA TEA VOL TEA TEA TEA TEA TEA TWD 95 SVI DNT TEA TEA TEA P 3 TWD 5 2

TEA 24 2

TEA 52 28 P 3 TWD 2 2

TEA 55 2

SAl 55 2

TWD 74 3 TWD 5 86 P

21 2

18 2

82 2

165 1 176 1 182 1 183 1 170 1 177 1 28 1

o 14 15 20 20 18 17 16 18 20 18 20 21 23 23 26 25 23 24 25 28 26 27 25 23 17 15 12 11 o

22 o

19 22 26 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 1

P 1 P 1 P 1 P 1 TEA TEA VOL ONT ONT ONT ONT ONT ONT SCI TWO TWO TWO TWO TWO TWD TWO TWO TWO TWO TWO TWO TWO TWD TWD TWO TWD TWO TWD TWO TWO TWO TWO TWO TWD TWO TWO TWO TWD TWO MCI o

76 78 78 78 81 85 86 90 90 91 93 94 96 98 100 100 99 100 100 98 97 95 93 91 88 84 81 77 o

TWO 0 TWO 19 30 41 TWO TWO 011 UTE LTE UTE UTE 015 008 UTE UTE UTE 014 UTE UTE UTE UTE UTE UTE UTE LTE UTE UTE UTE 008 UTE UTE 010 UTE 012 012 009 UTE UTE 002 LTE LTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE MRPC/PLUS POINT

-0.12

-0.32

+11. 67

-0.65

-0.52

-6.38

+11.06

-0.47

-0.12

-0.11

+1.14

-0.13

-0.21

-0.13

-0.10

-0.20

-1. 08

-1.08

+8.51

-0.18

-0.12

-0.15

-0.25

-0.18

-0.09

-0.79

-0.15

+11. 52

+11. 52

+0.54

-0.19

-0.34

+1.19

+7.90

+10.88

-11. 37

-10.56

-10.18

-10.94

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.24

+0.51

+0.51

+0.51

+0.51

+0.51 TO+61. 4 TO+69.5 TO+77.7 TO+85.9 TO+94.1 TO+102.3 TO+110.5 TO+118.6 TO+126.8 TO+135.0 TO+143.2 TO+151. 4 TO+159.5 TO+167.7 TO+175.9 TO+184.1 TO+192.3 TO+200.5 TO+208.6 TO+216.8 TO+225.0 TO+233.2 TO+241.4 TO+249.5 TO+257.7 TO+265.9 TO+274.1 TO+282.3 To+290.5 TO+298.6 TO+155.5 TO+147.3 TO+139.1 TO+130.9 05/02/02 13:29:37 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG 011 011 UTE UTE LTE LTE UTE UTE UTE UTE 015 015 008 008 UTE UTE UTE UTE UTE UTE 015 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTS LTE UTE UTE UTE UTE UTE UTE 008 008 UTE UTE UTE UTE 010 009 UTE UTE 013 012 013 012 010 009 UTE UTE UTE UTE 002 003 LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE WAR SLY SLY SLY SLY SLY TR WAR WAR WAR 4031 1003 4031 1003 1003 1003 4031 1003 2082 2082 4020 2082 2083 2082 2082 2126 2126 2126 4020 2083 2082 2083 4020 2083 2082 4020 2083 4020 4020 4020 2004 2004 4006 4002 4002 4002 4002 4002 4002 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 702 OUTLET INLET OUTLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET Page 76 of 155 PROBE 460S1 400PS 460S1 400PS 400PS 400PS 460S1 400PS 460HR 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460HR 460HR 460S1 460HR 460HR 460S1 460HR 460S1 460S1 460S1 460HR 460HR 460S1 460S1 460S1 460S1 460SI 460S1 460S1 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX 380EX

Framatome ANP Inc.

05/02/02 13:29:38 Customer Name: Oconee unit 1 Component: S/G B Page 77 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

8.46 27 P 1 TWO 49 LTE

+0.51 TO+122.7 LTE LTE 702 OUTLET 380EX 9.40 27 P 1 TWO 57 LTE

+0.51 TO+114.5 LTE LTE 702 OUTLET 380EX 10.60 27 P 1 TWO 66 LTE

+0.51 TO+106.4 LTE LTE 702 OUTLET 380EX 12.39 25 P 1 TWO 82 LTE

+0.51 TO+98.2 LTE LTE 702 OUTLET 380EX

11. 76 27 P 1 TWO 77 LTE

+0.51 TO+90.0 LTE LTE 702 OUTLET 380EX 12.21 27 P 1 TWO 81 LTE

+0.51 TO+81. 8 LTE LTE 702 OUTLET 380EX 12.03 28 P 1 TWO 79 LTE

+0.51 TO+73.6 LTE LTE 702 OUTLET 380EX

11. 55 28 P 1 TWO 75 LTE

+0.51 TO+65.5 LTE LTE 702 OUTLET 380EX 11.54 28 P 1 TWO 75 LTE

+0.51 TO+57.3 LTE LTE 702 OUTLET 380EX 11.66 30 P 1 TWO 76 LTE

+0.51 TO+49.1 LTE LTE 702 OUTLET 380EX 12.22 27 P 1 TWO 81 LTE

+0.51 TO+40.9 LTE LTE 702 OUTLET 380EX 13.10 26 P 1 TWO 89 LTE

+0.51 TO+32.7 LTE LTE 702 OUTLET 380EX 14.29 24 P 1 TWO 100 LTE

+0.51 TO+24.5 LTE LTE 702 OUTLET 380EX 13.33 26 P 1 TWO 91 LTE

+0.51 TO+16.4 LTE LTE 702 OUTLET 380EX 13.23 26 P 1 TWO 90 LTE

+0.51 TO+8.2 LTE LTE 702 OUTLET 380EX 12.34 25 P 1 TWO 82 LTE

+0.51 TO+O.O LTE LTE 702 OUTLET 380EX 13.05 3

P 1 TWO 89 LTE

+0.51 TO+351.8 LTE LTE 702 OUTLET 380EX 8.71 23 P 1 TWO 51 LTE

+0.51 TO+343.6 LTE LTE 702 OUTLET 380EX 7.23 22 P 1 TWO 40 LTE

+0.51 TO+335.5 LTE LTE 702 OUTLET 380EX 3.13 49 P 1 TWO 13 LTE

+0.51 TO+327.3 LTE LTE 702 OUTLET 380EX 6.69 4

P 1 TWO 36 LTE

+0.51 TO+319.1 LTE LTE 702 OUTLET 380EX 0.00 0

P 1 TWO 0 LTE

+0.51 TO+310.9 LTE LTE 702 OUTLET 380EX 0.00 0

P 1 TWO 0 LTE

+0.51 TO+315.0 LTE LTE CRACK2 702 OUTLET 380EX 2.40 21 P 1 TWO 10 LTE

+0.51 TO+306.8 LTE LTE 702 OUTLET 380EX 2.56 26 P 1 TWO 11 LTE

+0.51 TO+298.6 LTE LTE 702 OUTLET 380EX 3.44 29 P 1 TWO 19 LTE

+0.51 TO+290.5 LTE LTE 702 OUTLET 380EX 5.40 26 P 1 TWO 35 LTE

+0.51 TO+282.3 LTE LTE 702 OUTLET 380EX 7.00 25 P 1 TWO 50 LTE

+0.51 TO+274.1 LTE LTE 702 OUTLET 380EX 8.68 24 P 1 TWO 65 LTE

+0.51 TO+265.9 LTE LTE 702 OUTLET 380EX 10.22 24 P 1 TWO 80 LTE

+0.51 TO+257.7 LTE LTE 702 OUTLET 380EX

11. 34 23 P 1 TWO 91 LTE

+0.51 TO+249.5 LTE LTE 702 OUTLET 380EX

11. 40 24 P 1 TWO 92 LTE

+0.51 TO+241. 4 LTE LTE 702 OUTLET 380EX 12.23 23 P 1 TWO 100 LTE

+0.51 TO+233.2 LTE LTE 702 OUTLET 380EX

11. 40 24 P 1 TWO 92 LTE

+0.51 TO+225.0 LTE LTE 702 OUTLET 380EX

11. 30 23 P 1 TWO 91 LTE

+0.51 TO+216.8 LTE LTE 702 OUTLET 380EX 10.59 24 P 1 TWO 84 LTE

+0.51 TO+208.6 LTE LTE 702 OUTLET 380EX 9.22 27 P 1 TWO 70 LTE

+0.51 TO+200.5 LTE LTE 702 OUTLET 380EX 8.59 24 P 1 TWO 64 LTE

+0.51 TO+192.3 LTE LTE 702 OUTLET 380EX 7.16 24 P 1 TWO 51 LTE

+0.51 TO+184.1 LTE LTE 702 OUTLET 380EX 5.59 28 P 1 TWO 37 LTE

+0.51 TO+175.9 LTE LTE 702 OUTLET 380EX 2.86 35 P 1 TWO 14 LTE

+0.51 TO+167.7 LTE LTE 702 OUTLET 380EX 1.81 173 P 1 TWO 5 LTE

+0.51 TO+159.5 LTE LTE 702 OUTLET 380EX 2.93 14 P 1 TWO 14 LTE

+0.51 TO+151. 4 LTE LTE 702 OUTLET 380EX 0.00 0

P 1 TWO 0 LTE

+0.51 TO+143.2 LTE LTE 702 OUTLET 380EX 72 69 7.01 175 1 ONT UTE

-11. 01 UTE UTE 4002 OUTLET 460S1

1. 79 27 2

TEA UTE

-0.30 UTE UTE 2003 INLET 460HR 7.07 182 1 ONT LTE

+11.19 LTE LTS 4006 OUTLET 460S1 72 70 2.68 18 2

TEA UTE

-0.26 UTE UTE 2004 INLET 460HR 72 71 2.73 25 P 1 SCI UTE

-0.08 UTE UTS CL 2003 INLET 460HR 1.53 31 P 3 TWO 61 UTE

-0.08 TO+O.O UTE UTS 2003 INLET 460HR 1.45 22 P 3 TWO 59 UTE

-0.08 TO+8.9 UTE UTS 2003 INLET 460HR 0.95 19 P 3 TWO 48 UTE

-0.08 TO+17.8 UTE UTS 2003 INLET 460HR 0.67 22 P 3 TWO 40 UTE

-0.08 TO+26.7 UTE UTS 2003 INLET 460HR 0.34 33 P 3 TWO 29 UTE

-0.08 TO+35.6 UTE UTS 2003 INLET 460HR 0.55 21 P 3 TWO 0 UTE

-0.08 TO+44.4 UTE UTS 2003 INLET 460HR 0.97 169 P 3 TWO 0 UTE

-0.08 TO+306.7 UTE UTS 2003 INLET 460HR 1.10 173 P 3 TWO 51 UTE

-0.08 TO+315.6 UTE UTS 2003 INLET 460HR 0.77 157 P 3 TWO 43 UTE

-0.08 TO+324.4 UTE UTS 2003 INLET 460HR 0.92 51 P 3 TWO 47 UTE

-0.08 TO+342.2 UTE UTS 2003 INLET 460HR 1.19 35 P 3 TWO 53 UTE

-0.08 TO+351.1 UTE UTS 2003 INLET 460HR 0.58 75 P 3 TWO 37 UTE

-0.08 TO+333.3 UTE UTS 2003 INLET 460HR 72 72 5.77 24 2

TEA UTE

-0.23 UTE UTE 2004 INLET 460HR 72 74 4.64 28 2

TEA UTE

-0.25 UTE UTE 2004 INLET 460HR 72 82 4.41 24 2

TEA UTE

-0.15 UTE UTE 2068 INLET 460HR 72 84 10.08 26 2

TEA UTE

-0.14 UTE UTE 2068 INLET 460HR 72 88 9.29 24 2

TEA UTE

-0.16 UTE UTE 2068 INLET 460HR 72 99

1. 70 23 2

TEA UTE

-0.16 UTE UTE 2067 INLET 460HR 72 101 4.64 28 2

TEA UTE

-0.20 UTE UTE 2067 INLET 460HR 72 102 1.97 32 2

TEA UTE

-0.14 UTE UTE 2068 INLET 460HR 72 104 4.00 34 2

TEA UTE

-0.15 UTE UTE 2068 INLET 460HR 72 106 3.18 26 2

TEA UTE

-0.13 UTE UTE 2068 INLET 460HR 72 109 3.38 28 2

TEA UTE

-0.15 UTE UTE 2067 INLET 460HR 72 110 3.75 24 2

TEA UTE

-0.13 UTE UTE 2068 INLET 460HR 72 112 1.26 24 2

TEA UTE

-0.14 UTE UTE 2068 INLET 460HR 72 114 4.24 25 2

TEA UTE

-0.21 UTE UTE 2068 INLET 460HR

Framatome ANP Inc.

05/02/02 13:29:39 Customer Name: Oconee Unit 1 Component: S/G B Page 78 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

72 122 0.22 62 2

VOL 014

+0.80 014 014 4122 OUTLET 520SI 0.26 68 2

VOL 014

+1. 39 014 014 4122 OUTLET 520SI 5.77 24 2

TEA UTE

-0.15 UTE UTE 2067 INLET 460HR 72 123 0.09 90 2

VOL 014

+1. 25 014 014 4122 OUTLET 520SI 0.50 64 2

VOL 014

+0.74 014 014 4122 OUTLET 520SI

1. 64 23 2

TEA UTE

-0.20 UTE UTE 2067 INLET 460HR 72 126 9.52 186 1 DNT LTE

+11. 75 LTE LTE 4122 OUTLET 520SI 5.53 171 1 DNT UTS

+12.03 UTS UTS 4122 OUTLET 520SI

1. 70 30 2

TEA UTE

-0.20 UTE UTE 2073 INLET 460HR 72 129 0.35 71 P 3 TWD 10 010

+0.71 010 010 WAR 4122 OUTLET 520SI 0.12 67 2

VOL 014

+1. 00 014 014 4122 OUTLET 520SI 73 2

9.21 183 1 DNT LTE

+11. 87 LTE LTE 4031 OUTLET 460SI 5.79 11 P 1 DRS UTE

-0.28 UTE UTE SLY 1003 INLET 400PS 73 3

4.31 179 1 DNT LTE

+11. 51 LTE LTE 4031 OUTLET 460SI 1.92 30 P 1 DRS UTE

-0.82 UTE UTE SLV 1003 INLET 400PS 73 4

4.91 16 P 1 DRS UTE

-0.38 UTE UTE SLV 1003 INLET 400PS 73 5

5.77 15 P 1 DRS UTE

-0.32 UTE UTE SLY 1003 INLET 400PS 73 10 2.51 21 P 1 DRS UTE

-0.65 UTE UTE SLY 1003 INLET 400PS 73 11 4.12 17 P 1 DRS UTE

-0.62 UTE UTE SLY 1003 INLET 400PS 73 12 2.84 25 P 1 DRS UTE

-0.57 UTE UTE SLY 1003 INLET 400PS 73 13 5.21 27 2

TEA UTE

-0.16 UTE UTE 2083 INLET 460HR 0.23 120 P 3 TWO 2 012

-0.28 012 012 WAR 4020 INLET 460SI 73 14

1. 92 20 2

TEA UTE

-0.09 UTE UTE 2082 INLET 460HR 0.24 68 2

VOL 014

+0.72 015 014 4020 INLET 460SI 0.14 69 2

VOL 014

+1. 35 015 014 4020 INLET 460SI 73 15 2.39 22 2

TEA UTE

-0.17 UTE UTE 2083 INLET 460HR 0.25 37 P 3 TWD 3 013

-0.35 013 013 WAR 4020 INLET 460SI 73 19 1.10 28 2

TEA UTE

-0.13 UTE UTE 2083 INLET 460HR 73 21 1.55 26 2

TEA UTE

-0.17 UTE UTE 2083 INLET 460HR 73 23 2.36 25 2

TEA UTE

-0.18 UTE UTE 2083 INLET 460HR 73 25 2.58 28 2

TEA UTE

-0.14 UTE UTE 2083 INLET 460HR 73 28 1.26 19 2

TEA UTE

-0.11 UTE UTE 2082 INLET 460HR 73 31

1. 91 29 2

TEA UTE

-0.16 UTE UTE 2083 INLET 460HR 0.28 151 P 3 TWD 4 015

-0.11 015 015 WAR 905 INLET 460LW 73 32 4.68 23 2

TEA UTE

-0.13 UTE UTE 2082 INLET 460HR 73 37 3.03 27 2

TEA UTE

-0.16 UTE UTE 2083 INLET 460HR 73 38 7.05

25. 2 TEA UTE

-0.09 UTE UTE 2082 INLET 460HR 73 40 2.94 161 1 DNT UTS

-3.84 UTS UTS 4108 OUTLET 520SI 3.39 163 1 DNT UTS

-4.84 UTS UTS 4108 OUTLET 520SI 73 54 1.26 27 2

TEA UTE

-0.13 UTE UTE 2083 INLET 460HR 73 65 2.35 172 1 ONT LTE

+11. 67 LTE LTE 4002 OUTLET 460SI 3.18 28 2

TEA UTE

-0.19 UTE UTE 2006 INLET 460HR 73 67 7.41 l78 1 ONT UTE

-11.48 UTE UTE 4002 OUTLET 460SI 7.00 181 1 DNT LTE

+11.30 LTE LTS 4006 OUTLET 460SI 73 68 8.17 l73 1 DNT LTE

+11.11 LTE LTE 4002 OUTLET 460SI 7.11 175 1 DNT UTE

-11. 53 UTE UTE 4002 OUTLET 460SI 73 79 3.42 21 2

TEA UTE

-0.10 UTE UTE 2068 INLET 460HR 73 80 2.96 25 2

TEA UTE

-0.23 UTE UTE 2067 INLET 460HR 73 85 1.07 18 2

TEA UTE

-0.16 UTE UTE 2068 INLET 460HR 73 88

1. 68 23 2

TEA UTE

-0.13 UTE UTE 2073 INLET 460HR 73 90 7.83 27 2

TEA UTE

-0.14 UTE UTE 2073 INLET 460HR 73 91 6.08 22 2

TEA UTE

-0.12 UTE UTE 2074 INLET 460HR 73 93 0.18 68 2

VOL 013

+0.94 013 013 4123 OUTLET 520SI 73 94 2.60 26 2

TEA UTE

-0.19 UTE UTE 2073 INLET 460HR 73 95 3.49 36 2

TEA UTE

-0.14 UTE UTE 2074 INLET 460HR 73 97 0.51 87 P 3 TWD 9 007

-0.51 007 007 WAR 4123 OUTLET 520SI 73 98 4.22 21 2

TEA UTE

-0.19 UTE UTE 2073 INLET 460HR 73 101 3.31 36 2

TEA UTE

-0.13 UTE UTE 2074 INLET 460HR 73 104 4.05 23 2

TEA UTE

-0.19 UTE UTE 2073 INLET 460HR 73 107 2.61 29 2

TEA UTE

-0.19 UTE UTE 2108 INLET 460HR 73 108 1.39 34 2

TEA UTE

-0.14 UTE UTE 2073 INLET 460HR 73 109 0.31 52 P 3 TWO 6 007

-0.28 007 007 WAR 4123 OUTLET 520SI 73 110 3.11 22 2

TEA UTE

-0.15 UTE UTE 2073 INLET 460HR 73 111 4.48 17 2

TEA UTE

-0.15 UTE UTE 2074 INLET 460HR 73 112 4.31 22 2

TEA UTE

-0.20 UTE UTE 2073 INLET 460HR 73 113

1. 67 39 2

TEA UTE

-0.16 UTE UTE 2074 INLET 460HR 73 117 7.77 175 1 DNT LTE

+12.42 LTE LTE 4123 OUTLET 520SI 0.39 99 2

VOL 008

+0.62 008 008 4123 OUTLET 520SI 0.25 109 P 3 TWO 5 008

-0.61 008 008 WAR 4123 OUTLET 520SI 0.16 87 2

VOL 014

+0.95 014 014 4123 OUTLET 520SI 9.22 174 1 DNT UTE

-10.74 UTE UTE 4123 OUTLET 520SI 3.12 23 2

TEA UTE

-0.14 UTE UTE 2073 INLET 460HR 73 l18 6.01 175 1 DNT LTE

+l1.98 LTE LTE 4123 OUTLET 520SI 0.38 64 P 3 TWO 7 014

+0.70 014 014 WAR 4123 OUTLET 520SI 0.09 76 2

VOL 014

+1. 05 014 014 4123 OUTLET 520SI

Framatome ANP Inc.

05/02/02 13:29:40 Customer Name: Oconee Unit 1 Component: S/G B Page 79 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS MRPC!PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

7.76 172 1 DNT UTE

-10.10 UTE UTE 4123 OUTLET 520S1 73 119 8.80 168 1 DNT LTE

+10.49 LTE LTE 4122 OUTLET 520S1 7.94 171 1 DNT UTS

+11.84 UTS UTS 4123 OUTLET 520S1 0.17 75 2

VOL 014

+1.04 014 014 4130 INLET 460S1 73 121 7.66 166 1 DNT LTE

+10.45 LTE LTE 4122 OUTLET 520S1 8.15 175 1 DNT UTE

-10.74 UTE UTE 4123 OUTLET 520S1 2.88 29 2

TEA UTE

-0.19 UTE UTE 2073 INLET 460HR 73 129 7.79 173 1 DNT LTE

+11. 03 LTE LTE 4122 OUTLET 520S1 2.04 22 2

TEA UTE

-0.16 UTE UTE 2073 INLET 460HR 74 2

19.88 17 1

SCI LTE

+2.02 LTE LTE 705 OUTLET 380EX 74 3

5.09 27 P 1 DRS UTE

-0.85 UTE UTE SLV 1007 INLET 400PS 8.32 175 1 DNT LTE

+11. 77 LTE LTE 4034 OUTLET 460S1 74 4

5.56 27 P 1 DRS UTE

-0.85 UTE UTE SLV 1007 INLET 400PS 4.05 178 1 DNT 014

+23.01 014 014 4054 OUTLET 460S1 74 5

6.88 31 P 1 DRS UTE

-0.89 UTE UTE SLV 1007 INLET 400PS 74 7

3.98 19 P 1 DRS UTE

-0.76 UTE UTE SLV 1007 INLET 400PS 6.67 185 1 DNT LTE

+11.37 LTE LTE 4031 OUTLET 460S1 74 8

32.76 19 1

SCI LTE

+0.14 LTE LTE 705 OUTLET 380EX 37.78 19 1

SCI LTE

+0.21 LTE LTE 705 OUTLET 380EX 74 9

4.69 19 P 1 DRS UTE

-0.84 UTE UTE SLV 1007 INLET 400PS 3.20 178 1 DNT LTE

+11. 45 LTE LTE 4031 OUTLET 460S1 0.20 126 2 VOL 011

+1. 31 011 011 4031 OUTLET 460S1 0.37 64 2

VOL 014

+0.98 014 014 4031 OUTLET 460S1 74 10 3.20 19 P 1 DRS UTE

-0.77 UTE UTE SLV 1007 INLET 400PS 74 11 2.84 27 P 1 DRS UTE

-0.76 UTE UTE SLV 1007 INLET 400PS 8.48 179 1 DNT LTE

+10.28 LTE LTE 4031 OUTLET 460S1 74 12 5.62 28 P 1 DRS UTE

-0.80 UTE UTE SLV 1007 INLET 400PS 5.24 181 1 DNT LTE

+10.36 LTE LTE 4031 OUTLET 460S1 74 13 4.37 26 P 1 DRS UTE

-0.81 UTE UTE SLV 1007 INLET 400PS 5.56 29 P 1 DRS UTE

-2.05 UTE UTE SLV 1007 INLET 400PS 74 14 7.20 22 P 1 DRS UTE

-2.09 UTE UTE SLV 1007 INLET 400PS 4.99 24 P 1 DRS UTE

-0.67 UTE UTE SLV 1007 INLET 400PS 74 15 7.61 22 P 1 DRS UTE

-0.78 UTE UTE SLV 1007 INLET 400PS 6.90 23 P 1 DRS UTE

-2.06 UTE UTE SLV 1007 INLET 400PS 74 16 4.79 25 P 1 DRS UTE

-0.70 UTE UTE SLV 1007 INLET 400PS 5.65 23 P 1 DRS UTE

-2.00 UTE UTE SLV 1007 INLET 400PS 74 17 3.85 37 P 1 DRS UTE

-0.76 UTE UTE SLV 1.007 INLET 400PS 7.31 23 P 1 DRS UTE

-2.10 UTE UTE SLV 1007 INLET 400PS 3.56 33 P 1 DRS 015

-4.51 015 015 SLV 1007 INLET 400PS 7.40 180 1 DNT LTE

+11. 22 LTE LTE 4031 OUTLET 460S1 74 18 4.50 188 1 DNT LTE

+11. 27 LTE LTE 4031 OUTLET 460S1 3.30 19 P 1 DRS UTE

-0.73 UTE UTE SLV 1008 INLET 400PS 2.13 56 P 1 DRS 015

-4.63 015 015 SLV 1008 INLET 400PS 4.52 33 P 1 DRS 015

-6.45 015 015 SLV 1008 INLET 400PS 74 20 2.68 28 P 1 DRS UTE

-0.66 UTE UTE SLV 1008 INLET 400PS 7.46 27 P 1 DRS 015

-4.63 015 015 SLV 1008 INLET 400PS 74 21 3.97 17 P 1 DRS UTE

-0.69 UTE UTE SLV 1008 INLET 400PS 3.92 27 P 1 DRS 015

-4.64 015 015 SLV 1008 INLET 400PS 74 22 3.49 34 P 1 DRS UTE

-0.53 UTE UTE SLV 1008 INLET 400PS 5.21 18 P 1 DRS 015

-4.81 015 015 SLV 1008 INLET 400PS 74 23 3.41 15 P 1 DRS 015

-5.26 015 015 SLV 1008 INLET 400PS 74 24 0.52 53 P 1 VOL 015

-4.42 015 015 SLV 1008 INLET 400PS 0.38 45 P 1 VOL 015

-6.44 015 015 SLV 1008 INLET 400PS 74 25 2.13 47 P 1 DRS UTE

-0.63 UTE UTE SLV 1008 INLET 400PS 74 26 6.55 30 P 1 DRS UTE

-0.68 UTE UTE SLV 1008 INLET 400PS 74 27 4.51 29 P 1 DRS UTE

-0.66 UTE UTE SLV 1008 INLET 400PS 74 28 3.94 21 P 1 DRS UTE

-0.82 UTE UTE SLV 1004 INLET 400PS 74 29 2.38 17 P 1 DRS UTE

-0.43 UTE UTE SLV 1003 INLET 400PS

1. 48 113 P 2 VOL UTE

-0.17 UTE UTE SLV 1003 INLET 400PS 74 30 8.50 27 2

TEA UTE

-0.16 UTE UTE 2083 INLET 460HR 74 31 2.31 23 2

TEA UTE

-0.12 UTE UTE 2082 INLET 460HR 74 33 8.68 20 2

TEA UTE

-0.15 UTE UTE 2082 INLET 460HR 74 34

1. 81 24 2

TEA UTE

-0.18 UTE UTE 2083 INLET 460HR 74 36 2.55 20 2

TEA UTE

-0.13 UTE UTE 2083 INLET 460HR 74 38 1.56 17 2

TEA UTE

-0.13 UTE UTE 2083 INLET 460HR 74 56

1. 32 29 2

TEA UTE

-0.13 UTE UTE 2082 INLET 460HR 74 58 3.11 26 2

TEA UTE

-0.29 UTE UTE 2007 INLET 460HR 74 60 0.82 85 1

VOL UTS

-23.02 TO-20.19 UTS UTS 4002 OUTLET 460SI 74 62 2.52 27 2

TEA UTE

-0.39 UTE UTE 2005 INLET 460HR 74 69 0.64 23 P 4 TWD 79 UTE

-1. 59 UTE UTE 2005 INLET 460HR

1. 30 15 2

SVI UTE

-1. 59 UTE UTE TR 2005 INLET 460HR 74 70

1. 65 26 P 1 MCI UTE

-0.41 UTE UTS CL 2006 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.40 TO+126.0 UTE UTS 2006 INLET 460HR 0.58 35 p 3 TWD 16 UTE

-0.40 TO+135.0 UTE UTS 2006 INLET 460HR

1. 43 21 P 3 TWD 39 UTE

-0.41 TO+144.0 UTE UTS 2006 INLET 460HR

Framatome ANP Inc.

05/02/02 13:29:40 Customer Name: Oconee Unit 1 Component: S/G B Page 80 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

0.74 29 P 3 TWD 20 UTE

-0.41 TO+153.0 UTE UTS 2006 INLET 460HR 0.15 3

P 3 TWD 4 UTE

-0.41 TO+162.0 UTE UTS 2006 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.41 TO+171.0 UTE UTS 2006 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.40 TO+99.0 UTE UTS 2006 INLET 460HR 0.20 78 P 3 TWO 5 UTE

-0.40 TO+108.0 UTE UTS 2006 INLET 460HR 0.73 28 P 3 TWO 20 UTE

-0.40 TO+ll7.0 UTE UTS 2006 INLET 460HR 0.67 31 P 3 TWO 18 UTE

-0.40 TO+126.0 UTE UTS 2006 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.40 TO+135.0 UTE UTS 2006 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.40 TO+63.0 UTE UTS 2006 INLET 460HR 0.12 121 P 3 TWD 3 UTE

-0.40 TO+72.0 UTE UTS 2006 INLET 460HR 0.37 40 P 3 TWD 10 UTE

-0.40 TO+81.0 UTE UTS 2006 INLET 460HR 0.65 34 P 3 TWO 18 UTE

-0.40 TO+90.0 UTE UTS 2006 INLET 460HR 0.34 36 P 3 TWD 9 UTE

-0.40 TO+99.0 UTE UTS 2006 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.40 TO+l08.0 UTE UTS 2006 INLET 460HR 74 73 6.11 28 2

TEA UTE

-0.24 UTE UTE 2067 INLET 460HR 74 82 5.31 20 2

TEA UTE

-0.16 UTE UTE 2067 INLET 460HR 74 86 6.44 26 2

TEA UTE

-0.36 UTE UTE 2109 INLET 460HR 74 87

1. 94 21 P 1 SCI UTE

-0.11 UTE UTS CL 2073 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.11 TO+65.9 UTE UTS 2073 INLET 460HR 0.59 14 P 3 TWO 37 UTE

-0.11 TO+74.6 UTE UTS 2073 INLET 460HR 0.66 12 P 3 TWO 42 UTE

-0.11 TO+83.4 UTE UTS 2073 INLET 460HR 0.78 42 P 3 TWO 49 UTE

-0.11 TO+92.2 UTE UTS 2073 INLET 460HR

1. 40 25 P 3 TWO 88 UTE

-0.11 TO+I01. 0 UTE UTS 2073 INLET 460HR 0.71 29 P 3 TWD 45 UTE

-0.11 TO+109.8 UTE UTS 2073 INLET 460HR 0.40 33 P 3 TWD 25 UTE

-0.11 TO+llS.5 UTE UTS 2073 INLET 460HR 0.38 18 P 3 TWO 24 UTE

-0.11 TO+127.3 UTE UTS 2073 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.11 TO+136.1 UTE UTS 2073 INLET 460HR 74 93 2.95 23 2

TEA UTE

-0.21 UTE UTE 2109 INLET 460HR 74 95 3.58 26 2

TE~

UTE

-0.24 UTE UTE 2109 INLET 460HR 74 96 3.03 31 2

TEA UTE

-0.14 UTE UTE 2073 INLET 460HR 74 97 6.03 25 2

TEA UTE

-0.18 UTE UTE 2109 INLET 460HR 74 100 3.92 24 2

TEA UTE

-0.15 UTE UTE 2073 INLET 460HR 74 101 2.32 25 2

TEA UTE

-0.20 UTE UTE 2108 INLET 460HR 74 105 2.42 24 2

TEA UTE

-0.17 UTE UTE 2108 INLET 460HR 74 106 2.01 20 2

TEA UTE

-0.12 UTE UTE 2073 INLET 460HR 74 107 2.53 24 2

TEA UTE

-0.18 UTE UTE 2108 INLET 460HR 2.09 15 P 1 SCI UTE

-0.30 UTE UTE CL 2108 INLET 460HR 0.25 8

P 3 TWO 0 UTE

-0.30 TO+99.0 UTE UTE 2108 INLET 460HR 0.44 14 P 3 TWD 20 UTE

-0.30 TO+90.0 UTE UTE 2108 INLET 460HR 1.53 12 P 3 TWD 37 UTE

-0.30 TO+81.0 UTE UTE 2108 INLET 460HR

1. 75 14 P 3 TWO 39 UTE

-0.30 TO+72.0 UTE UTE 2108 INLET 460HR 0.75 18 P 3 TWO 26 UTE

-0.30 TO+63.0 UTE UTE 2108 INLET 460HR 0.27 28 P 3 TWO 16 UTE

-0.30 TO+54.0 UTE UTE 2108 INLET 460HR 0.16 16 P 3 TWO 0 UTE

-0.30 TO+45.0 UTE UTE 2108 INLET 460HR 74 llO 0.55 77 P 3 TWD 10 014

+0.66 014 014 WAR 4123 OUTLET 520SI 74 116 9.30 173 1 DNT LTE

+11.13 LTE LTE 4123 OUTLET 520SI 0.17 74 2

VOL 014

+1.05 014 014 4123 OUTLET 520SI 8.18 179 1 DNT UTE

-10.45 UTE UTE 4123 OUTLET 520S1 2.58 20 2

TEA UTE

-0.14 UTE UTE 2073 INLET 460HR 74 118 6.90 162 1 DNT LTE

+11.65 LTE LTE 4123 OUTLET 520SI 0.45 74 P 3 TWO 8 013

-0.67 013 013 WAR 4123 OUTLET 520SI 0.06 88 2

VOL 014

+1.0S 014 014 4123 OUTLET 520SI S.35 175 1 DNT UTE

-10.00 UTE UTE 4123 OUTLET 520SI 4.47 29 2

TEA UTE

-0.11 UTE UTE 2074 INLET 460HR 74 125

11. 34 174 1 ONT LTE

+10.S5 LTE LTE 4123 OUTLET 520S1 75 5

9.38 27 P 1 DRS UTE

-0.79 UTE UTE SLV 1007 INLET 400PS 75 8

6.53 27 P 1 DRS UTE

-0.75 UTE UTE SLV 1007 INLET 400PS 6.33 177 1 ONT LTE

+11.57 LTE LTE 4034 OUTLET 460SI 75 9

4.57 19 P 1 DRS UTE

-0.75 UTE UTE SLV 1007 INLET 400PS 4.65 18 P 1 DRS 015

-4.68 015 015 SLV 1007 INLET 400PS 3.39 28 P 1 DRS 015

-6.12 015 015 SLV 1007 INLET 400PS 5.43 132 P 3 VOL 015

-11.34 015 015 TUB 1007 INLET 400PS 4.76 172 1 DNT LTE

+11.26 LTE LTE 4034 OUTLET 460SI 75 11 5.95 24 P 1 DRS UTE

-0.79 UTE UTE SLV 1007 INLET 400PS S.19 179 1 DNT LTE

+10.55 LTE LTE 4034 OUTLET 460S1 75 13 5.36 19 P 1 DRS UTE

-0.65 UTE UTE SLV 1007 INLET 400PS 9.20 1

1 ONT LTS

-13.93 LTS LTS 4034 OUTLET 460S1 0.38 151 2 VOL 014

-0.73 014 014 4034 OUTLET 460S1 75 14 4.74 22 P 1 DRS UTE

-0.79 UTE UTE SLV 1007 INLET 400PS 75 15 5.79 25 P 1 DRS UTE

-0.80 UTE UTE SLV 1007 INLET 400PS 75 16 3.48 32 P 1 DRS UTE

-0.67 UTE UTE SLV 1007 INLET 400PS 75 17 3.76 208 P 1 DRS UTE

-0.83 UTE UTE SLV 1007 INLET 400PS 6.03 lSI 1 ONT LTE

+11.41 LTE LTE 4034 OUTLET 460S1 75 18 54.14 10 1

SCI LTE

+0.14 LTE LTE 705 OUTLET 380EX 75 19 7.13 178 1 ONT LTE

+10.92 LTE LTE 4034 OUTLET 460SI

Framatome ANP Inc.

05/02/02 13:29:41 Customer Name: Oconee Unit 1 Component: S/G B Page 81 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -. MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG eHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

75 20 3.76 180 1 DNT LTE

+11. 42 LTE LTE 4034 OUTLET 460SI 75 21 5.27 21 P 1 DRS UTE

-0.66 UTE UTE SLV 1007 INLET 400PS 75 22 9.68 23 P 1 DRS UTE

-0.64 UTE UTE SLV 1007 INLET 400PS 75 23 6.75 26 P 1 DRS UTE

-0.70 UTE UTE SLY 1007 INLET 400PS 75 24 4.29 25 P 1 DRS UTE

-0.71 UTE UTE SLY 1007 INLET 400PS 75 25 7.55 20 P 1 DRS UTE

-0.64 UTE UTE SLY 1007 INLET 400PS 75 26 4.05 30 P 1 DRS UTE

-0.59 UTE UTE SLY 1007 INLET 400PS 75 28 3.39 28 P 1 DRS UTE

-0.58 UTE UTE SLY 1007 INLET 400PS 75 29 9.18 22 P 1 DRS UTE

-0.60 UTE UTE SLY 1007 INLET 400PS 75 30 6.68 23 P 1 DRS UTE

-0.66 UTE UTE SLY 1007 INLET 400PS 5.76 19 P 1 DRS 015

-5.92 015 015 SLY 1007 INLET 400PS 75 31 7.05 23 P 1 DRS UTE

-0.59 UTE UTE SLY 1007 INLET 400PS 75 32 9.17 21 P 1 DRS UTE

-0.71 UTE UTE SLY 1007 INLET 400PS 75 33 4.04 21 P 1 DRS UTE

-0.74 UTE UTE SLY 1007 INLET 400PS 75 35 3.09 19 P 1 DRS UTE

-0.78 UTE UTE SLY 1007 INLET 400PS 75 47 2.56 28 2

TEA UTE

-0.13 UTE UTE 2082 INLET 460HR 75 66 2.57 20 2

TEA UTE

-0.33 UTE UTE 2005 INLET 460HR 75 70 2.78 28 2

TEA UTE

-0.11 UTE UTE 2005 INLET 460HR 75 73 4.76 24 2

TEA UTE

-0.26 UTE UTE 2006 INLET 460HR 75 75 2.07 45 2

TEA UTE

-0.19 UTE UTE 2067 INLET 460HR 75 77 5.27 23 2

TEA UTE

-0.20 UTE U'I'E 2067 INLET 460HR 75 85 3.28 30 2

TEA UTE

-0.35 UTE UTE 2109 INLET 460HR 75 89 3.45 31 2

TEA UTE

-0.44 UTE UTE 2109 INLET 460HR 75 90 2.73 23 2

TEA UTE

-0.19 UTE UTE 2073 INLET 460HR 75 92 5.00 21 2

TEA UTE

-0.14 UTE UTE 2073 INLET 460HR 75 93 0.51 16 2

TWD 42 UTE

-3.66 UTE UTS 2109 INLET 460HR 0.25 195 2 MAl UTE

-3.66 UTE UTS 2109 INLET 460HR 75 95 0.49 28 2

MAl UTE

-3.62 UTE UTS 2109 INLET 460HR 1.14 28 2

TWD 84 UTE

-3.62 UTE UTS 2109 INLET 460HR 75 102 0.74 58 2

TEA UTE

-0.10 UTE UTE 2108 INLET 460HR 75 103 2.13 27 2

TEA UTE

-0.22 UTE UTE 2073 INLET 460HR 75 105 0.85 37 2

TEA UTE

-0.15 UTE UTE 2073 INLET 460HR 75 107 2.96 30 2

TEA UTE

-0.14 UTE UTE 2073 INLET 460HR 75 108 5.14 27 2

TEA UTE

-0.19 UTE UTE 2108 INLET 460HR 75 110 2.09 21 2

TEA UTE

-0.19 UTE UTE 2108 INLET 460HR 75 111

1. 66 38 2

TEA UTE

-0.20 UTE UTE 2073 INLET 460HR 75 116 7.17 13 1

SAl UTE

-2.15 UTE UTE 603 INLET 410MB 75 117 2.67 27 2

TEA UTE

-0.23 UTE UTE 2073 INLET 460HR 75 118 6.43 163 1 DNT LTE

+10.68 LTE LTE 4123 OUTLET 520SI 75 122 7.10 168 1 DNT LTE

+10.06 LTE LTE 4123 OUTLET 520SI 7.21 176 1 DNT UTE

-10.17 UTE UTE 4123 OUTLET 520SI 75 123 6.26 171 1 DNT LTE

+10.32 LTE LTE 4123 OUTLET 520SI 0.13 70 2

VOL 014

+0.88 014 014 4123 OUTLET 520SI 0.19 118 P 3 TWD 3 014

+0.79 014 014 WAR 4123 OUTLET 520SI 8.27 173 1 DNT UTE

-10.42 UTE UTE 4123 OUTLET 520S1 2.04 27 2

TEA UTE

-0.16 UTE UTE 2108 INLET 460HR 75 125 11.11 16 P 1 SCI UTE

-0.15 UTE UTS CL 2073 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.15 TO+302.9 UTE UTS 2073 INLET 460HR

1. 61 169 P 3 TWD 12 UTE

-0.15 To+311. 7 UTE UTS 2073 INLET 460HR 2.05 178 P 3 TWO 15 UTE

-0.15 TO+320.5 UTE UTS 2073 INLET 460HR 2.61 5

P 3 TWO 20 UTE

-0.15 TO+329.3 UTE UTS 2073 INLET 460HR 2.36 17 P 3 TWO 18 UTE

-0.15 TO+338.0 UTE UTS 2073 INLET 460HR 2.23 18 P 3 TWO 17 UTE

-0.15 TO+346.8 UTE UTS 2073 INLET 460HR 2.23 29 p 3 TWD 17 UTE

-0.15 TO+355.6 UTE UTS 2073 INLET 460HR 3.24 24 P 3 TWD 25 UTE

-0.15 TO+4.4 UTE UTS 2073 INLET 460HR 3.97 19 P 3 TWO 30 UTE

-0.15 TO+13.2 UTE UTS 2073 INLET 460HR 4.43 21 P 3 TWD 34 UTE

-0.15 TO+22.0 UTE UTS 2073 INLET 460HR 3.45 28 P 3 TWD 26 UTE

-0.15 TO+30.7 UTE UTS 2073 INLET 460HR 3.79 25 P 3 TWD 29 UTE

-0.15 TO+39.5 UTE UTS 2073 INLET 460HR 4.47 19 P 3 TWD 34 UTE

-0.15 TO+48.3 UTE UTS 2073 INLET 460HR 4.50 21 P 3 TWD 34 UTE

-0.15 TO+57.1 UTE UTS 2073 INLET 460HR 5.61 21 P 3 TWD 42 UTE

-0.15 TO+65.9 UTE UTS 2073 INLET 460HR 6.96 21 P 3 TWD 53 UTE

-0.15 TO+74.6 UTE UTS 2073 INLET 460HR 7.46 21 P 3 TWD 56 UTE

-0.15 TO+83.4 UTE UTS 2073 INLET 460HR 7.76 18 P 3 TWD 59 UTE

-0.15 TO+92.2 UTE UTS 2073 INLET 460HR 7.17 14 P 3 TWD 54 UTE

-0.15 T0+101. 0 UTE UTS 2073 INLET 460HR 3.47 11 P 3 TWD 26 UTE

-0.15 TO+109.8 UTE UTS 2073 INLET 460HR 3.80 22 P 3 TWD 29 UTE

-0.15 TO+118.5 UTE UTS 2073 INLET 460HR 3.76 24 P 3 TWD 28 UTE

-0.15 TO+127.3 UTE UTS 2073 INLET 460HR 3.30 25 P 3 TWD 25 UTE

-0.15 TO+136.1 UTE UTS 2073 INLET 460HR 2.27 13 P 3 TWO 17 UTE

-0.15 TO+144.9 UTE UTS 2073 INLET 460HR

1. 64 40 P 3 TWO 12 UTE

-0.15 TO+153.7 UTE UTS 2073 INLET 460HR 2.25 41 P 3 TWD 17 UTE

-0.15 TO+162.4 UTE UTS 2073 INLET 460HR 3.16 34 P 3 TWO 24 UTE

-0.15 TO+171.2 UTE UTS 2073 INLET 460HR 3.13 29 P 3 TWO 24 UTE

-0.15 TO+180.0 UTE UTS 2073 INLET 460HR

Framatome ANP Inc.,

05/02/02 13:29:42 Customer Name: Oconee Unit 1 Component: S/G B Page 82 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

2.44 30 P 3 TWO 18 UTE

-0.15 TO+188.8 UTE UTS 2073 INLET 460HR 2.17 30 P 3 TWO 16 UTE

-0.15 TO+197.6 UTE UTS 2073 INLET 460HR

1. 85 40 P 3 TWO 14 UTE

-0.15 TO+206.3 UTE UTS 2073 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.15 TO+215.1 UTE UTS 2073 INLET 460HR 75 126 0.27 83 2

VOL 013

+0.74 013 013 4123 OUTLET 520SI 76 64 2.28 19 2

TEA UTE

-0.17 UTE UTE 4002 OUTLET 460SI 1.56 18 2

TEA UTE

-0.18 UTE UTE 2005 INLET 460HR 0.59 0

P 3 TWO 10 009

-0.10 008 009 WAR 4006 OUTLET 460SI 76 67 2.43 22 2

TEA UTE

-0.51 UTE UTE 2006 INLET 460HR 76 74 2.22 165 1 ONT UTS

+1. 93 UTS UTS 4033 OUTLET 460SI

1. 83 190 1 ONT UTS

+3.07 UTS UTS 4033 OUTLET 46031

1. 34 347 1 ONT UTS

+8.84 UTS UTS 4033 OUTLET 460SI

1. 49 182 1 ONT UTS

+7.82 UTS UTS 4033 OUTLET 460SI 76 77 4.91 24 2

TEA UTE

-0.14 UTE UTE 2012 INLET 460HR 76 78 2.98 24 2

TEA UTE

-0.29 UTE UTE 2011 INLET 460HR 76 82 2.73 18 2

TEA UTE

-0.21 UTE UTE 2011 INLET 460HR 76 87 3.12 23 2

TEA UTE

-0.23 UTE UTE 2012 INLET 460HR 76 97 1.90 21 2

TEA UTE

-0.16 UTE UTE 2012 INLET 460HR 76 98 2.97 26 2

TEA UTE

-0.14 UTE UTE 2011 INLET 460HR 76 103 5.36 30 2

TEA UTE

-0.15 UTE UTE 2012 INLET 460HR 76 104 0.19 188 P 3 TWO 0 UTE

-0.38 TO+56.4 UTE UTS 2011 INLET 460HR 0.32 23 P 3 TWO 0 UTE

-0.38 TO+303.6 UTE UTS 2011 INLET 460HR 0.41 170 P 3 TWO 10 UTE

-0.38 TO+312.3 UTE UTS 2011 INLET 460HR 1.10 190 P 3 TWO 17 UTE

-0.38 TO+321. 0 UTE UTS 2011 INLET 460HR 0.70 156 P 3 TWO 11 UTE

-0.38 TO+13.0 UTE UTS 2011 INLET 460HR 0.71 186 P 3 TWO 11 UTE

-0.38 TO+21. 7 UTE UTS 2011 INLET 460HR 0.64 188 P 3 TWO 10 UTE

-0.38 TO+30.4 UTE UTS 2011 INLET 460HR 0.44 184 P 3 TWO 7 UTE

-0.38 TO+39.0 UTE UTS 2011 INLET 460HR 0.25 194 P 3 TWO 4 UTE

-0.38 TO+47.7 UTE UTS 2011 INLET 460HR

1. 51 189 P 3 TWO 24 UTE

-0.38 TO+329.6 UTE UTS 2011 INLET 460HR

1. 57 190 P 3 TWO 25 UTE

-0.38 TO+338.3 UTE UTS 2011 INLET 460HR 1.52 187 P 3 TWO 24 UTE

-0.38 TO+347.0 UTE UTS 2011 INLET 460HR 1.20 180 P 3 TWO 19 UTE

-0.38 TO+355.7 UTE UTS 2011 INLET 460HR 2.75 20 P 1 SCI UTE

-0.38 UTE UTS CL 2011 INLET 460HR 0.87 159 P 3 TWO 14 UTE

-0.38 TO+4.3 UTE UTS 2011 INLET 460HR 76 106 1.86 24 2

TEA UTE

-0.09 UTE UTE 2071 INLET 460HR 76 110 4.06 173 1 ONT LTE

+10.94 LTE LTE 4043 OUTLET 460S1 6.06 178 1 ONT UTE

-11. 75 UTE UTE 4043 OUTLET 460S1 3.67 30 2

TEA UTE

-0.09 UTE UTE 2071 INLET 460HR 76 117 7.13 175 1 ONT LTE

+10.03 LTE LTE 4043 OUTLET 460S1 8.50 181 1 ONT UTE

-10.16 UTE UTE 4043 OUTLET 460S1 76 120 5.35 167 1 ONT LTE

+9.53 LTE LTE 4043 OUTLET 460S1 8.55 173 1 ONT LTE

+10.40 LTE LTE 4043 OUTLET 460S1 0.44 88 2

VOL 012

-0.75 012 012 4043 OUTLET 460SI 7.21 181 1 ONT UTE

-11.19 UTE UTE 4043 OUTLET 460S1 2.28 42 2

TEA UTE

-0.09 UTE UTE 2071 INLET 460HR 76 121 10.72 175 1 ONT LTE

+10.39 LTE LTE 4043 OUTLET 460S1 10.06 175 1 ONT UTE

-11.30 UTE UTE 4043 OUTLET 460S1 2.28 24 2

TEA UTE

-0.21 UTE UTE 2072 INLET 460HR 76 123 5.11 27 2

TEA UTE

-0.14 UTE UTE 2072 INLET 460HR 3.90 25 P 1 SCI UTE

-0.21 UTE UTE CL 2072 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.21 TO+302.2 UTE UTE 2072 INLET 460HR 1.20 36 p 3 TWO 27 UTE

-0.21 TO+311.1 UTE UTE 2072 INLET 460HR 1.00 11 P 3 TWO 23 UTE

-0.21 TO+320.0 UTE UTE 2072 INLET 460HR 2.80 18 P 3 TWO 64 UTE

-0.21 TO+328.9 UTE UTE 2072 INLET 460HR

1. 97 28 P 3 TWO 45 UTE

-0.21 TO+337.8 UTE UTE 2072 INLET 460HR 0.52 26 P 3 TWO 12 UTE

-0.21 TO+346.7 UTE UTE 2072 INLET 460HR 0.00 0

p 3 TWO 0 UTE

-0.21 TO+355.6 UTE UTE 2072 INLET 460HR 77 4

5.75 22 P 1 ORS UTE

-0.77 UTE UTE SLV 1008 INLET 400PS 9.49 184 1 ONT LTS

-14.83 LTS LTS 4038 OUTLET 460S1 10.25 186 1 ONT LTS

-l3.37 LTS LTS 4038 OUTLET 460S1 4.99 191 1 ONT LTS

-11. 71 LTS LTS 4038 OUTLET 460S1 77 6

34.55 14 1

SCI LTE

+0.83 LTE LTE 708 OUTLET 380EX 64.78 26 1

MCI LTE

+0.66 LTE LTE 708 OUTLET 380EX 77 12 6.34 187 1 ONT LTE

+11.44 LTE LTE 4038 OUTLET 460S1 0.30 130 p 3 TWO 5 014

+0.74 014 014 WAR 4038 OUTLET 460S1 77 19 4.56 28 P 1 ORS UTE

-9*66 UTE UTE SLV 1008 INLET 400PS 7.78 181 1 ONT LTE

+11.21 LTE LTE 4038 OUTLET 460S1 77 21 2.77 31 P 1 ORS UTE

-0.59 UTE UTE SLY 1008 INLET 400PS 7.42 183 1 ONT LTE

+10.92 LTE LTE 4038 OUTLET 460S1 77 26 4.88 27 P 1 ORS UTE

-0.69 UTE UTE SLV 1008 INLET 400PS 7.07 178 1 ONT LTE

+11.22 LTE LTE 4038 OUTLET 460S1 5.61 177 1 ONT LTE

+11. 96 LTE LTE 4038 OUTLET 460S1 77 27 64.25 18 1

MC!

LTE

+1.44 LTE LTE 708 OUTLET 380EX 56.18 17 1

MCI LTE

+1.73 LTE LTE 708 OUTLET 380EX

Framatome ANP Inc.

05/02/02 13:29:43 Customer Name: Oconee Unit 1 Component: S/G B Page 83 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

46.33 18 1

SCI LTE

+2.07 LTE LTE 708 OUTLET 380EX 77 28 5.49 182 1 DNT LTE

+11.29 LTE LTE 4038 OUTLET 460S1 5.68 173 1 DNT LTE

+11. 73 LTE LTE 4038 OUTLET 460S1 77 30 5.68 18 P 1 DRS UTE

-0.50 UTE UTE SLV 1008 INLET 400PS 5.46 189 1 DNT LTE

+10.78 LTE LTE 4038 OUTLET 460S1 77 31 6.40 29 P 1 DRS UTE

-0.72 UTE UTE SLV 1008 INLET 400PS 77 33 6.89 178 1 DNT LTS

-11. 73 LTS LTS 4038 OUTLET 46081 77 34 3.80 26 P 1 DRS UTE

-0.69 UTE UTE 8LV 1008 INLET 400P8 77 40 4.94 167 1 DNT LTE

+10.13 LTE LTE 4103 OUTLET 46081 9.16 165 1 DNT LTE

+11. 61 LTE LTE 4103 OUTLET 46081 77 41 8.48 170 1 DNT LTE

+9.96 LTE LTE 4103 OUTLET 46081 2.38 174 1 DNT LTE

+11. 71 LTE LTE 4103 OUTLET 46081 77 44 0.87 19 2

TEA UTE

-0.11 UTE UTE 2123 INLET 460HR 77 47 7.65 172 1 DNT LTE

+11. 96 LTE LT8 4113 OUTLET 52081 77 49 5.48 173 1 DNT LTE

+10.08 LTE LT8 4113 OUTLET 52081 77 50 0.06 73 2

VOL LTS

+8.74 LT8 LT8 4101 OUTLET 46081 77 55 2.71 181 1 DNT UT8

-0.67 UT8 UT8 4101 OUTLET 46081 77 56 6.40 172 1 DNT LTE

+11. 00 LTE LTE 4101 OUTLET 46081 3.41 14 2

TEA UTE

-0.12 UTE UTE 2123 INLET 460HR 77 57 8.92 172 1 DNT LTE

+10.97 LTE LTE 4101 OUTLET 46081 4.43 35 2

TEA UTE

-0.14 UTE UTE 2122 INLET 460HR 77 60

1. 49 31 P 1 8CI UTE

-1. 33 UTE UT8 TR 2008 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-1.33 TO+135.0 UTE UT8 2008 INLET 460HR 0.68 56 P 3 TWO 52 UTE

-1. 33 TO+126.0 UTE UT8 2008 INLET 460HR 1.20 42 P 3 TWO 96 UTE

-1. 33 TO+117.0 UTE UT8 2008 INLET 460HR 1.15 48 P 3 TWD 92 UTE

-1. 33 TO+108.0 UTE UT8 2008 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-1. 33 TO+99.0 UTE UTS 2008 INLET 460HR 1.28 28 2

MAl UTE

-3.78 UTE UT8 TR 2008 INLET 460HR 1.28 28 2

TWO 100 UTE

-3.78 UTE UT8 2008 INLET 460HR 77 62 0.11 60 2

VOL LT8

+2.84 LTS LT8 4005 OUTLET 46081 77 70 3.70 17 2

TEA UTE

-0.16 UTE UTE 2007 INLET 460HR 4.65 181 1 ONT LTE

+11.36 LT8 LTE 4004 INLET 46081 77 71 5.00 19 2

TEA UTE

-0.17 UTE UTE 2008 INLET 460HR 5.93 175 1 DNT LTE

+11. 04 LT8 LTE 4004 INLET 46081 77 77 4.43 27 2

TEA UTE

-0.23 UTE UTE 2011 INLET 460HR 77 78 4.38 173 1 DNT LTE

+5.08 LTE LTE 4033 OUTLET 46081 4.32 24 2

TEA UTE

-0.25 UTE UTE 2012 INLET 460HR 77 79 3.25 24 2

TEA UTE

-0.17 UTE UTE 2011 INLET 460HR 0.57 184 2 DNT LTE

+4.83 LTE LTE 4033 OUTLET 46081 3.42 178 1 DNT LTE

+6.51 LTE LTE 4033 OUTLET 46081 5.32 177 1 ONT LTE

+12.69 LTE LTE 4033 OUTLET 46081 77 80 5.62 175 1 ONT LT8

-12.18 LT8 LT8 4033 OUTLET 46081 4.65 25 2

TEA UTE

-0.16 UTE UTE 2012 INLET 460HR 77 84 3.09 20 2

TEA UTE

-0.21 UTE UTE 2012 INLET 460HR 77 86 5.26 176 1 ONT LTE

+11.86 LTE LTE 4033 OUTLET 46081 4.18 22 2

TEA UTE

-0.18 UTE UTE 2012 INLET 460HR 77 87 4.42 20 2

TEA UTE

-0.19 UTE UTE 2011 INLET 460HR 6.86 177 1 DNT LTE

+12.25 LTE LTE 4033 OUTLET 46081 77 88 2.87 17 2

TEA UTE

-0.20 UTE UTE 2012 INLET 460HR 77 89 4.74 28 2

TEA UTE

-0.17 UTE UTE 2011 INLET 460HR 77 93 5.17 170 1 DNT LT8

-11.17 LT8 LT8 4033 OUTLET 46081 77 94 3.88 30 2

TEA UTE

-0.19 UTE UTE 2012 INLET 460HR 77 95

1. 67 22 2

TEA UTE

-0.20 UTE UTE 2011 INLET 460HR 77 96 2.48 23 2

TEA UTE

-0.24 UTE UTE 2012 INLET 460HR 77 97 2.78 22 2

TEA UTE

-0.19 UTE UTE 2011 INLET 460HR 77 98 3.06 23 2

TEA UTE

-0.21 UTE UTE 2012 INLET 460HR 77 102 5.03 23 2

TEA UTE

-0.15 UTE UTE 2012 INLET 460HR 77 103 4.62 24 2

TEA UTE

-0.25 UTE UTE 2011 INLET 460tIR 77 108 0.07 99 2

VOL 014

+1.15 014 014 4043 OUTLET 46081 77 109 1.20 30 2

TEA UTE

-0.14 UTE UTE 2071 INLET 460HR 77 110 3.48 28 2

TEA UTE

-0.23 UTE UTE 2072 INLET 460HR 77 111 0.08 86 2

VOL 014

+1.07 014 014 4043 OUTLET 46081 4.37 27 2

TEA UTE

-0.10 UTE UTE 2071 INLET 460HR 77 112 5.45 166 1 ONT LTE

+7.28 LTE LTE 4043 OUTLET 460S1 4.60 179 1 DNT LTE

+10.62 LTE LTE 4043 OUTLET 46081 8.67 179 1 ONT UTE

-8.75 UTE UTE 4043 OUTLET 46081 5.82 182 1 ONT UTE

-11.74 UTE UTE 4043 OUTLET 46081 77 115 0.11 87 2

VOL 014

+1.19 014 014 4043 OUTLET 46081 2.04 32 2

MAl UTE

-0.58 UTE UTE C8 2072 INLET 460HR 2.04 32 2

TWO 99 UTE

-0.58 UTE UTE 2072 INLET 460HR 77 117 6.24 176 1 DNT LT8

-11.23 LT8 LT8 4043 OUTLET 460SI 2.05 31 2

TEA UTE

-0.18 UTE UTE 2072 INLET 460HR 77 118 6.81 33 2

TEA UTE

-0.13 UTE UTE 2071 INLET 460HR 77 120 6.20 166 1 DNT LTE

+10.42 LTE LTE 4043 OUTLET 46081 6.94 172 1 ONT UTE

-11. 42 UTE UTE 4043 OUTLET 46081

Framatome ANP Inc.

05/02/02 13:29:44 Customer Name: Oconee Unit 1 Component: S/G B Page 84 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS..., MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

2.58 27 2

TEA UTE

-0.15 UTE UTE 2071 INLET 460HR 77 121 6.93 172 1 DNT LTE

+10.42 LTE LTE 4043 OUTLET 460SI 0.60 84 2

VOL 008

+0.66 008 008 4043 OUTLET 460SI 3.05 24 2

TEA UTE

-0.19 UTE UTE 2072 INLET 460HR 78 1

56.93 18 1

SCI LTE

+1. 07 LTE LTE 708 OUTLET 380EX 56.94 24 1

SCI LTE

+1.16 LTE LTE 708 OUTLET 380EX 23.58 26 1

SCI LTE

+1. 81 LTE LTE 708 OUTLET 380EX 45.50 8

1 SCI LTE

+1. 72 LTE LTE 708 OUTLET 380EX 78 2

72.72 9

1 MCI LTE

+2.35 LTE LTE 708 OUTLET 380EX 78 3

55.63 23 1

MCI LTE

+2.18 LTE LTE 708 OUTLET 380EX 78 5

4.74 18 P 1 DRS UTE

-0.65 UTE UTE SLV 1006 INLET 400PS 5.30 178 1 DNT LTE

+9.83 LTE LTE 4038 OUTLET 460SI 5.22 178 1 DNT LTE

+10.90 LTE LTE 4038 OUTLET 460SI 6.47 178 1 DNT LTE

+11. 26 LTE LTE 4038 OUTLET 460SI 78 6

4.05 22 P 1 DRS UTE

-0.69 UTE UTE SLV 1006 INLET 400PS 9.12 171 1 DNT LTE

+11. 36 LTE LTE 4054 OUTLET 460SI 7.70 176 1 DNT LTS

+11.16 LTS LTS 4038 OUTLET 460SI 78 7

6.92 171 1 DNT LTE

+10.82 LTE LTE 4054 OUTLET 460SI 78 8

8.38 180 1 DNT LTS

-12.92 LTS LTS 4038 OUTLET 460SI 4.09 187 1 DNT LTS

-11.79 LTS LTS 4038 OUTLET 460SI 2.32 157 1 DNT 013

+3.08 013 013 4038 OUTLET 460SI 78 9

48.91 22 1

Mel LTE

+1. 90 LTE LTE 708 OUTLET 380EX 78 10 6.50 179 1 DNT LTE

+11.11 LTE LTE 4038 OUTLET 460SI 78 11 7.04 179 1 DNT LTE

+11. 62 LTE LTE 4038 OUTLET 460SI 5.50 178 1 DNT LTE

+10.93 LTE LTE 4038 OUTLET 460SI 78 14 4.79 181 1 DNT LTE

+10.98 LTE LTE 4038 OUTLET 460SI 78 15 7.62 182 1 DNT LTE

+10.98 LTE LTE 4038 OUTLET 460SI 78 17 5.89 177 1 DNT LTE

+11. 03 LTE LTE 4038 OUTLET 460SI 78 18 6.82 179 1 DNT LTE

+11. 08 LTE LTE 4038 OUTLET 460SI 78 21 5.70 177 1 DNT LTE

+11.10 LTE LTE 4038 OUTLET 460SI 78 22 5.01 29 P 1 DRS UTE

-0.77 UTE UTE SLV 1008 INLET 400PS 5.69 180 1 DNT LTE

+10.75 LTE LTE 4038 OUTLET 460S1 4.80 180 1 DNT LTE

+11.22 LTE LTE 4038 OUTLET 460S1 78 25 4.75 177 1 DNT LTS

-11. 77 LTS LTS 4038 OUTLET 460SI 5.97 183 1 DNT LTS

-12.88 LTS LTS 4038 OUTLET 460SI 78 26 6.85 181 1 DNT LTE

+11.38 LTE LTE 4038 OUTLET 460S1 78 28 5.45 186 1 DNT LTE

+10.29 LTE LTE 4038 OUTLET.

460SI 78 29 3.68 35 P 1 DRS UTE

-0.62 UTE UTE SLV 1008 INLET 400PS 5.47 187 1 DNT LTE

+10.48 LTE LTE 4038 OUTLET 460SI 78 34 7.52 177 1 DNT LTS

-11. 85 LTS LTS 4103 OUTLET 460SI 0.59 0

P 3 TWD 9 013

+0.38 013 013 WAR 4103 OUTLET 460SI 78 36 1.13 33 2

MAl UTE

-3.60 UTE UTS 2127 INLET 460HR 1.13 33 2

TWD 96 UTE

-3.60 UTE UTS 2127 INLET 460HR 78 39 6.67 160 1 DNT LTE

+10.21 LTE LTE 4103 OUTLET 460SI 3.14 161 1 DNT LTE

+11. 45 LTE LTE 4103 OUTLET 460SI 5.00 166 1 DNT UTS

+19.24 UTE UTS 4113 OUTLET 520SI 4.69 168 1 DNT UTS

+20.31 UTE UTS 4113 OUTLET 520SI

1. 58 11 2

TEA UTE

-0.21 UTE UTE 2122 INLET 460HR 78 40 27.76 9

1 Mel LTE

+1. 97 LTE LTE 708 OUTLET 380EX 78 41 7.37 181 1 DNT LTE

+9.99 LTE LTE 4103 OUTLET 460SI 4.20 179 1 DNT LTE

+11.47 LTE LTE 4103 OUTLET 460SI 0.25 56 P 3 TWD 5 013

+0.63 013 013 WAR 4113 OUTLET 520SI 0.47 79 P 3 TWD 10 013

-0.73 013 013 WAR 4113 OUTLET 520SI 3.28 27 2

TEA UTE

-0.15 UTE UTE 2123 INLET 460HR 78 46 5.04 183 1 DNT LTS

-12.07 LTS LTS 4103 OUTLET 460SI 78 47 35.20 32 1

Mel LTE

+2.14 LTE LTE 708 OUTLET 380EX 78 49 7.22 169 1 DNT LTE

+10.25 LTE LTE 4103 OUTLET 460SI 4.64 22 2

TEA UTE

-0.17 UTE UTE 2123 INLET 460HR 78 54 3.53 185 1 DNT UTS

-0.21 UTS UTS 4103 OUTLET 460SI 78 55 9.20 181 1 DNT LTE

+10.31 LTE LTE 4103 OUTLET 460SI 3.28 25 2

TEA UTE

-0.23 UTE UTE 2122 INLET 460HR 78 57 2.71 22 2

TEA UTE

-0.16 UTE UTE 2007 INLET 460HR 6.94 179 1 DNT LTE

+10.62 LTE LTE 4003 INLET 460SI 78 60 2.20 13 2

TEA UTE

-0.14 UTE UTE 2008 INLET 460HR 78 62 1.52 124 1 VOL 008

+10.84 008 009 4006 OUTLET 460SI 78 63 2.81 174 1 DNT LTE

+5.12 LTE LTE 4005 OUTLET 460SI 1.82 172 1 DNT LTE

+6.16 LTE LTE 4005 OUTLET 460SI 78 66 6.17 25 2

TEA UTE

-0.16 UTE UTE 2008 INLET 460HR 78 67 0.17 74 2

VOL 015

+31.32 UTS 015 4004 INLET 460SI 78 68 0.29 70 2

SAl 013

+31. 82 014 013 4004 INLET 460S1 0.29 70 2

TWD 49 013

+31.82 014 013 4004 INLET 460SI 78 69 1.09 20 2

TEA UTE

-0.14 UTE UTE 2007 INLET 460HR 78 70 5.92 25 2

TEA UTE

-0.15 UTE UTE 2007 INLET 460HR 5.26 178 1 DNT LTE

+11.03 LTS LTE 4004 INLET 460SI 78 72 4.20 23 2

TEA UTE

-0.15 UTE UTE 2007 INLET 460HR

Framatome ANP Inc.

Customer Name: Oconee unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 79 79 79 79 79 79 79 79 79 79 79 79 79 79 79 74 76 78 80 82 86 88 89 93 94 95 98 99 100 102 103 104 106 110 111 114.

115 118 119 120 122 124 9

10 11 12 20 23 25 33 34 40 41 47 48 49 51 5.48 4.32 0.62 0.62

1. 69 3.21 7.06 2.68 10.22 20.69 2.06 2.85 5.71 9.16 4.86
1. 79
1. 36 7.85 5.86 15.22 24.99 25.70 7.25 0.84 4.84
1. 07 7.39 2.72 26.53 26.75 6.18
1. 50 3.38 5.79 117.50 18.45 6.40 7.65 0.10 22.95 17.29 32.35 3.60 6.09 2.99 33.05 8.39 5.14 4.92 3.86 3.76 0.51 2.20 2.67 7.05 2.53 7.05 7.96 2.53 7.67 1.10
1. 75
1. 41
1. 01
1. 87 6.68 4.16 1.21
1. 21 0.71 5.53 4.88 5.42 5.24 0.67 173 1 23 2

18 2

18 2

26 2

20 2

167 1 168 1 31 1

23 1

23 2

179 1 24 2

178 1 20 2

176 1 171 1 177 1 25 2

29 1

25 1

15 1

22 2

28 2

17 2

16 2

180 1 27 2

20 1

26 1

25 2

25 2

35 2

167 1 43 1

9 1

173 1 175 1 75 2

10 1

32 1

19 1

30 2

27 2

19 2

26 1

32 1

179 1 173 1 26 P 1 19 P 1 135 P 3 26 2

20 2

332 1 144 1 172 1 172 1 169 1 172 1 173 1 168 1 170 1 171 1 183 1 177 1 27 2

29 2

29 2

28 2

174 1 181 1 25 2

176 1 26 2

DNT TEA TWD 49 SVI TEA TEA DNT DNT MCI MCI TEA DNT TEA DNT TEA DNT DNT DNT TEA MCI MCI MCI TEA TEA TEA TEA DNT TEA SCI MCI TEA TEA TEA DNT MCI SCI DNT DNT VOL MCI MCI MCI TEA TEA TEA SCI SCI DNT DNT DRS DRS TWD 7 TEA TEA DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT TEA MAl TWD 85 TWD 82 DNT DNT TEA DNT TEA LTE UTE UTE UTE UTE UTE LTE LTE LTE LTE UTE LTE UTE LTS UTE LTS LTS LTS UTE LTE LTE LTE UTE UTE UTE UTE LTS UTE LTE LTE UTE UTE UTE LTE LTE LTE LTE UTE 014 LTE LTE LTE UTE UTE UTE LTE LTE LTS LTS UTE UTE 015 UTE UTE LTS LTS LTS LTE LTE LTE LTE UTS UTS UTS LTE LTE UTE UTE UTE UTE LTE LTE UTE LTE UTE

+11. 37

-0.23

-0.81

-0.81

-0.22

-0.12

+4.80

+6.65

+1.18

+2.30

-0.16

+12.31

-0.13

-12.56

-0.19

-11. 35

-12.24

-11.41

-0.17

+1. 09

+1. 35

+2.54

-0.14

-0.20

-0.22

-0.23

-11.59

-0.18

+0.77

+1. 01

-0.22

-0.22

-0.10

+11.66

+2.09

+1. 01

+7.32

-8.81

+0.93

+0.56

+0.80

+1. 74

-0.14

-0.24

-0.19

+1.10

+0.84

-11.86

-11.91

-0.92

-0.88

-0.78

-0.18

-0.15

-12.04

-2.68

-11. 91

+9.89

+11. 54

+11.54

+9.89

+8.03

+9.03

+10.14

+11.71

+10.17

-0.26

-3.57

-3.57

-3.58

+10.75

+12.27

-0.16

+10.15

-0.31 05/02/02 13:29:45 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG LTS LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE LTE LTE UTE UTE LTS LTS UTE UTE LTS LTS LTS LTS LTS LTS UTE UTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE LTS LTS UTE UTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE 014 014 LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTS LTS LTS LTS UTE UTE UTE UTE 015 015 UTE UTE UTE UTE LTS LTS LTS LTS LTS LTS LTE LTE LTE LTE LTE LTE LTE LTE UTS UTS UTS UTS UTS UTS LTE LTE LTE LTE UTE UTE UTE UTS UTE UTS UTE UTS LTE LTE LTE LTE UTE UTE LTE LTE UTE UTE CS SLV SLV WAR 4004 2007 2007 2007 2011 2077 4033 4033 710 710 2018 4033 2017 4033 2018 4033 4033 4033 2017 709 709 709 2018 2017 2018 2017 4033 2017 709 709 2017 2017 2071 4039 709 709 4043 4043 4043 709 709 709 2071 2072 2072 709 709 4038 4038 1005 1005 905 2123 2123 4104 4104 4104 4103 4103 4104 4104 4104 4104 4104 4103 4103 2122 2122 2122 2122 4103 4103 2123 4103 2127 INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET OUTLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET INLET Page 85 of 155 PROBE 460S1 460HR 460HR 460HR 460HR 460HR 460SI 460SI 380EX 380EX 460HR 460S1 460HR 460S1 460HR 460SI 460S1 460SI 460HR 380EX 380EX 380EX 460HR 460HR 460HR 460HR 460SI 460HR 380EX 380EX 460HR 460HR 460HR 460SI 380EX 380EX 460SI 460S1 460SI 380EX 380EX 380EX 460HR 460HR 460HR 380EX 380EX 460S1 460SI 400PS 400PS 460LW 460HR 460HR 460S1 460S1 460S1 460S1 460S1 460S1 460S1 460S1 460S1 460SI 460S1 460S1 460HR 460HR 460HR 460HR 460S1 460S1 460HR 460S1 460HR

Framatome ANP Inc.

05/02/02 13:29:46 Customer Name: Oconee Unit 1 Component: S/G B Page 86 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS - MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

79 56 8.68 179 1 DNT LTE

+10.79 LTE LTE 4103 OUTLET 460SI 3.02 29 2

TEA UTE

-0.18 UTE UTE 2123 INLET 460HR 79 57 5.74 166 1 DNT LTE

+10.35 LTE LTE 4103 OUTLET 460SI

1. 40 51 2

TEA UTE

-0.12 UTE UTE 2122 INLET 460HR 79 65 3.27 21 2

TEA UTE

-0.33 UTE UTE 2007 INLET 460HR 79 69 2.13 25 2

TEA UTE

-0.18 UTE UTE 2007 INLET 460HR 79 71 3.20 28 2

TEA UTE

-0.15 UTE UTE 2007 INLET 460HR 79 73 3.68 27 2

TEA UTE

-0.12 UTE UTE 2007 INLET 460HR 79 74 3.74 180 1 DNT LTE

+11.13 LTS LTE 4004 INLET 460SI 79 75 3.16 17 2

TEA UTE

-0.22 UTE UTE 2007 INLET 460HR 5.32 179 1 DNT LTE

+10.93 LTS LTE 4004 INLET 460SI 79 78 1.25 170 1 DNT LTE

+9.53 LTE LTE 4109 OUTLET 460SI 0.96 16 2

TEA UTE

-0.18 UTE UTE 2017 INLET 460HR 79 79 0.57 34 2

TEA UTE

-0.24 UTE UTE 2017 INLET 460HR 79 80 3.14 24 2

TEA UTE

-0.23 UTE UTE 2018 INLET 460HR 79 82 5.90 169 1 DNT LTE

+4.77 LTE LTE 4033 OUTLET 460SI 4.45 171 1 DNT LTE

+5.59 LTE LTE 4033 OUTLET 460SI 4.05 175 1 DNT LTE

+6.65 LTE LTE 4033 OUTLET 460SI

4. 63 22 2

TEA UTE

-0.15 UTE UTE 2018 INLET 460HR 79 83 7.45 173 1 DNT LTS

-12.08 LTS LTS 4033 OUTLET 460SI 3.32 177 1 DNT LTS

-18.29 LTS LTS 4033 OUTLET 460SI 6.53 174 1 DNT LTS

-19.51 LTS LTS 4033 OUTLET 460SI 1.37 26 2

TEA UTE

-0.25 UTE UTE 2017 INLET 460HR 79 89 1.80 26 2

TEA UTE

-0.13 UTE UTE 2018 INLET 460HR 79 90 9.10 179 1 DNT LTE

+12.35 LTE LTE 4033 OUTLET 460SI 1.57 23 2

TEA UTE

-0.22 UTE UTE 2017 INLET 460HR 79 91 5.26 172 1 DNT LTS

-12.54 LTS LTS 4033 OUTLET 460SI 2.48 179 1 DNT LTS

-10.91 LTS LTS 4033 OUTLET 460SI 2.10 19 2

TEA UTE

-0.16 UTE UTE 2018 INLET 460HR 79 95 2.50 22 2

TEA UTE

-0.10 UTE UTE 2018 INLET 460HR 79 96 0.77 20 2

SVI UTE

-0.38 UTE UTE CL/CS 2017 INLET 460HR 0.77 20 2

TWD 61 UTE

-0.38 UTE UTE 2017 INLET 460HR 79 97 7.12 174 1 DNT LTS

-11.20 LTS LTS 4033 OUTLET 460SI 3.86 21 2

TEA UTE

-0.12 UTE UTE 2018 INLET 460HR 79 98 6.16 25 2

TEA UTE

-0.14 UTE UTE 2017 INLET 460HR 79 101 3.15 22 2

TEA UTE

-0.13 UTE UTE 2018 INLET 460HR 79 106 6.37 177 1 DNT LTE

+12.08 LTE LTE 4033 OUTLET 460SI 1.65 40 2

TEA UTE

-0.29 UTE UTE 2017 INLET 460HR 79 107 3.00 32 2

TEA UTE

-0.13 UTE UTE 2018 INLET 460HR 79 111 3.46 28 2

TEA UTE

-0.17 UTE UTE 2018 INLET 460HR 79 114 2.02 25 2

TEA UTE

-0.24 UTE UTE 2072 INLET 460HR 5.03 169 1 DNT LTE

+11. 87 LTE LTE 4039 OUTLET 460SI 79 115 2.27 26 2

TEA UTE

-0.14 UTE UTE 2071 INLET 460HR 79 116 0.32 48 2

VOL 014

+1.13 014 014 4043 OUTLET 460SI 0.44 76 2

SVI 014

+0.95 014 014 4043 OUTLET 460SI 0.45 76 2

TWD 28 014

+0.95 014 014 4043 OUTLET 460SI 2.43 16 2

TEA UTE

-0.28 UTE UTE 2072 INLET 460HR 79 117 1.29 63 2

SVI 014

+1. 05 014 014 4043 OUTLET 460SI 1.29 63 2

TWD 42 014

+1. 05 014 014 4043 OUTLET 460SI 79 119

1. 90 26 2

TEA UTE

-0.14 UTE UTE 2124 INLET 460HR 79 121 5.39 173 1 DNT LTS

-11.04 LTS LTS 4043 OUTLET 460SI 2.60 47 2

TEA UTE

-0.13 UTE UTE 2124 INLET 460HR 79 122 3.25 17 2

TEA UTE

-0.15 UTE UTE 2072 INLET 460HR 79 126 0.22 52 2

VOL 014

+1.02 014 014 4043 OUTLET 460SI 79 127 4.86 173 1 DNT LTS

-11. 37 LTS LTS 4043 OUTLET 460SI 0.06 1162 VOL 014

+2.02 014 014 4043 OUTLET 460SI 0.08 73 2

VOL 014

+1.09 014 014 4043 OUTLET 460SI 8.46 176 1 DNT UTE

-10.34 UTE UTE 4043 OUTLET 460SI 80 2

4.83 17 P 1 DRS UTE

-0.72 UTE UTE SLV 1005 INLET 400PS 6.44 174 1 DNT LTE

+10.65 LTE LTE 4038 OUTLET 460SI 80 4

5.13 20 P 1 DRS UTE

-0.75 UTE UTE SLV 1005 INLET 400PS 0.16 165 P 3 TWD 3 011

-0.82 011 011 WAR 4038 OUTLET 460SI 0.16 73 2

VOL 012

+1. 06 012 012 4038 OUTLET 460SI 80 5

5.89 19 P 1 DRS UTE

-0.75 UTE UTE SLV 1005 INLET 400PS 80 6

3.03 29 P 1 DRS UTE

-0.75 UTE UTE SLV 1005 INLET 400PS 80 7

4.19 24 P 2 DRS UTE

-0.74 UTE UTE SLV 1005 INLET 400PS 80 8

6.13 21 P 1 DRS UTE

-0.67 UTE UTE SLV 1005 INLET 400PS 80 9

3.75 25 P 1 DRS UTE

-0.69 UTE UTE SLV 1005 INLET 400PS 80 10 5.54 21 P 1 DRS UTE

-0.85 UTE UTE SLV 1005 INLET 400PS 0.28 160 P 3 TWD 5 011

-0.74 011 011 WAR 4038 OUTLET 460SI 80 11 2.84 21 P 1 DRS UTE

-0.73 UTE UTE SLV 1005 INLET 400PS 0.66 154 P 3 TWD 11 014

+0.82 014 014 WAR 4038 OUTLET 460SI 80 14 1.24 17 2

TEA UTE

-0.20 UTE UTE 2122 INLET 460HR 80 16 0.31 114 P 3 TWD 8 013

+0.73 013 013 WAR 4092 OUTLET 460SI 80 19 0.21 61 2

VOL 014

-4.51 014 014 4092 OUTLET 460SI

Framatome ANP Inc.

05/02/02 13:29:47 Customer Name: Oconee Unit 1 Component: S/G B Page 87 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS "C MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

80 22

1. 78 34 2

TEA UTE

-0.21 UTE UTE 2122 INLET 460HR 80 32

1. 36 30 2

SAl UTE

-3.37 UTE UTS 2122 INLET 460HR 1.36 30 2

TWD 89 UTE

-3.37 UTE UTS 2122 INLET 460HR 80 34 0.82 25 P 4 SVI UTE

-1.18 UTE UTE TR 2122 INLET 460HR 0.82 25 P 4 TWD 94 UTE

-1.18 UTE UTE 2122 INLET 460HR 80 35 2.24 19 2

TEA UTE

-0.16 UTE UTE 2123 INLET 460HR 80 37 2.38 163 1 DNT UTS

-15.51 UTS UTS 4104 OUTLET 460S1 80 39 3.99 165 1 DNT UTS

-14.80 UTS UTS 4104 OUTLET 460S1 3.21 164 1 DNT UTS

-13.77 UTS UTS 4104 OUTLET 460SI 2.55 132 1 DNT UTS

-2.65 UTS UTS 4104 OUTLET 460S1 2.36 157 1 DNT UTS

-0.42 UTS UTS 4104 OUTLET 460SI 2.38 156 1 DNT UTS

-1. 54 UTS UTS 4104 OUTLET 460S1 2.50 168 1 DNT UTE

-12.36 UTE UTE 4104 OUTLET 460S1 3.57 166 1 DNT UTE

-11. 30 UTE UTE 4104 OUTLET 460S1 3.90 167 1 DNT UTE

-11. 04 UTE UTE 4104 OUTLET 460SI 3.44 166 1 DNT UTE

-10.07 UTE UTE 4104 OUTLET 460S1 80 47

1. 79 40 2

TEA UTE

-0.15 UTE UTE 2123 INLET 460HR 80 48 1.03 23 2

SAl UTE

-3.58 UTE UTS 2122 INLET 460HR

1. 03 23 2

TWD 65 UTE

-3.58 UTE UTS 2122 INLET 460HR 80 53 1.92 15 2

TEA UTE

-0.13 UTE UTE 2123 INLET 460HR 80 59

1. 69 185 1 DNT LTE

+7.21 LTE LTE 4003 INLET 460SI 80 61

1. 41 19 2

TEA UTE

-0.20 UTE UTE 2007 INLET 460HR 80 68 2.68 20 2

TEA UTE

-0.12 UTE UTE 2008 INLET 460HR 80 70 1.28 15 2

TEA UTE

-0.11 UTE UTE 2008 INLET 460HR 80 72

1. 99 19 2

TEA UTE

-0.13 UTE UTE 2007 INLET 460HR 80 75 3.46 22 2

TEA UTE

-0.13 UTE UTE 2007 INLET 460HR 80 80 0.62 26 2

TEA UTE

-0.24 UTE UTE 2017 INLET 460HR 80 81 3.13 29 2

TEA UTE

-0.14 UTE UTE 2018 INLET 460HR 80 82

1. 82 26 2

TEA UTE

-0.23 UTE UTE 2017 INLET 460HR 80 83 2.31 21 2

TEA UTE

-0.14 UTE UTE 2018 INLET 460HR 80 84 1.07 18 2

TEA UTE

-0.21 UTE UTE 2017 INLET 460HR 80 85 3.99 17 2

TEA UTE

-0.15 UTE UTE 2018 INLET 460HR 80 87 2.07 19 2

TEA UTE

-0.13 UTE UTE 2018 INLET 460HR 80 89 3.53 24 2

TEA UTE

-0.12 UTE UTE 2018 INLET 460HR 80 95 2.47 21 2

TEA UTE

-0.18 UTE UTE 2018 INLET 460HR 80 97 2.01 23 2

TEA UTE

-0.10 UTE UTE 2018 INLET 460HR 80 102

1. 73 17 2

TEA UTE

-0.18 UTE UTE 2017 INLET 460HR 80 103 3.55 24 2

TEA UTE

-0.14 UTE UTE 2018 INLET 460HR 80 108

1. 49 55 2

TEA UTE

-0.13 UTE UTE 2017 INLET 460HR 80 112 3.36 27 2

TEA UTE

-0.12 UTE UTE 2071 INLET 460HR 80 113 4.02 28 2

TEA UTE

-0.17 UTE UTE 2072 INLET 460HR 80 116 0.07 89 2

VOL 014

+0.90 014 014 4039 OUTLET 460SI 80 117 10.46 175 1 DNT LTE

+10.29 LTE LTE 4043 OUTLET 460SI 1.11 181 1 DNT LTE

+11. 65 LTE LTE 4043 OUTLET 460SI 9.80 176 1 DNT UTE

-9.12 UTE UTE 4043 OUTLET 460SI

1. 91 20 2

TEA UTE

-0.15 UTE UTE 2072 INLET 460HR 80 118 2.84 169 1 DNT LTE

+11.44 LTE LTE 4043 OUTLET 460SI 0.34 56 P 3 TWD 10 008

-0.59 008 008 WAR 4043 OUTLET 460SI 7.32 173 1 DNT UTE

-9.15 UTE UTE 4043 OUTLET 460SI 80 123 0.25 85 2

VOL 014

+0.74 014 014 4043 OUTLET 460SI 80 127 0.22 70 2

VOL 011

+0.76 011 011 4043 OUTLET 460SI 0.30 69 2

VOL 014

+0.80 014 014 4043 OUTLET 460SI 0.13 110 2 VOL 014

+1. 34 014 014 4043 OUTLET 460SI 81 2

6.27 40 P 1 DRS UTE

-0.23 UTE UTE SLV 1005 INLET 400PS

1. 92 40 P 1 DRS 015

-6.55 015 015 SLV 1005 INLET 400PS 81 4

0.80 44 P 1 DRS 015

-6.33 015 015 SLV 1004 INLET 400PS 0.21 90 2

TWD 0 012

+1.26 012 012 4038 OUTLET 460SI 0.67 97 P 3 TWD 12 012

+0.79 012 012 WAR 4038 OUTLET 460SI 0.21 90 2

VOL 012

+1.26 012 012 4038 OUTLET 460SI 0.20 57 2

VOL 013

+1. 41 013 013 4038 OUTLET 460SI 81 5

4.51 20 P 1 DRS UTE

-0.84 UTE UTE SLV 1005 INLET 400PS 0.07 88 2

VOL 003

+1.03 003 003 4038 OUTLET 460SI 81 6

3.16 15 P 1 DRS UTE

-0.69 UTE UTE SLV 1005 INLET 400PS 4.07 13 P 1 DRS 015

-4.62 015 015 SLV 1005 INLET 400PS 4.14 15 P 1 DRS 015

-6.73 015 015 SLV 1005 INLET 400PS 81 10 5.50 18 P 1 DRS UTE

-0.70 UTE UTE SLV 1004 INLET 400PS 2.41 19 P 1 DRS 015

-4.18 015 015 SLV 1004 INLET 400PS 81 16 0.56 82 P 3 TWD 13 009

-0.72 009 009 WAR 4092 OUTLET 460SI 81 24 2.14 29 2

TEA UTE

-0.21 UTE UTE 2122 INLET 460HR 81 36 2.31 34 2

TEA UTE

-0.20 UTE UTE 2122 INLET 460HR 81 40 2.96 158 1 DNT UTE

-2.14 UTE UTE 4104 OUTLET 460SI 81 58 0.39 141 P 3 TWD 9 007

+0.38 007 007 WAR 4104 OUTLET 460SI 81 61 4.35 355 1 DNT LTE

+5.25 LTE LTE 4005 OUTLET 460SI 81 65 0.80 8

2 SAl UTE

-1.20 UTE UTE TR 2008 INLET 460HR 0.80 8

2 TWD 14 UTE

-1.20 UTE UTE 2008 INLET 460HR

Framatome ANP Inc.

05/02/02 13:29:48 Customer Name: Oconee Unit 1 Component: S/G B Page 88 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS - MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

81 68 2.24 26 2

TEA UTE

-0.16 UTE UTE 2007 INLET 460HR 81 69 7.20 22 2

TEA UTE

-0.13 UTE UTE 2008 INLET 460HR 81 70 2.37 23 2

TEA UTE

-0.11 UTE UTE 2007 INLET 460HR 81 71 2.48 24 2

TEA UTE

-0.11 UTE UTE 2008 INLET 460HR 81 75 4.71 30 2

TEA UTE

-0.23 UTE UTE 2007 INLET 460HR 81 76 2.23 28 2

TEA UTE

-0.08 UTE UTE 2008 INLET 460HR 81 79 2.94 20 2

TEA UTE

-0.22 UTE UTE 2018 INLET 460HR 81 81 2.60 18 2

TEA UTE

-0.21 UTE UTE 2018 INLET 460HR 81 83

1. 47 17 2

TEA UTE

-0.16 UTE UTE 2018 INLET 460HR 81 84 4.36 23 2

TEA UTE

-0.15 UTE UTE 2017 INLET 460HR 81 85 2.36 22 2

TEA UTE

-0.15 UTE UTE 2018 INLET 460HR 81 86 0.47 23 2

TEA UTE

-0.23 UTE UTE 2017 INLET 460HR 81 93 2.06 19 2

TEA UTE

-0.24 UTE UTE 2018 INLET 460HR 81 96 1.93 29 2

TEA UTE

-0.22 UTE UTE 2017 INLET 460HR 81 103 2.12 11 2

TEA UTE

-0.18 UTE UTE 2018 INLET 460HR 81 105 2.14 8

2 TEA UTE

-0.15 UTE UTE 2018 INLET 460HR 81 106 3.08 34 2

TEA UTE

-0.17 UTE UTE 2017 INLET 460HR 81 107 3.65 27 2

TEA UTE

-0.14 UTE UTE 2018 INLET 460HR 81 112 0.21 119 2 VOL 014

+0.48 014 014 4039 OUTLET 460S1 81 113 2.47 18 2

TEA UTE

-0.13 UTE UTE 2071 INLET 460HR 81 115 1.25 25 2

TEA UTE

-0.16 UTE UTE 2124 INLET 460HR 81 116 4.15 170 1 ONT UTE

-9.81 UTE UTE 4087 OUTLET 460S1 6.67 173 1 ONT LTE

+11.00 LTE LTE 4039 OUTLET 460S1 6.22 174 1 ONT LTE

+11. 74 LTE LTE 4039 OUTLET 460S1 81 118 6.95 174 1 ONT LTE

+11. 63 LTE LTE 4043 OUTLET 460S1 6.26 177 1 ONT UTE

-9.91 UTE UTE 4043 OUTLET 460S1 81 119 0.37 55 P 3 TWO 11 008

-0.65 008 008 WAR 4043 OUTLET 460S1 81 121 4.59 29 2

TEA UTE

-0.15 UTE UTE 2071 INLET 460HR 81 122 0.10 86 2

VOL 015

-0.79 015 015 4043 OUTLET 460S1 81 126 0.88 15 2

VOL 014

+1. 46 014 014 4043 OUTLET 460S1 3.39 29 2

TEA UTE

-0.18 UTE UTE 2071 INLET 460HR 82 6

2.23 16 P 1 VOL 015

-6.65 015 015 SLV 1004 INLET 400PS 0.16 72 2

VOL 013

+0.87 013 013 4038 OUTLET 460SI 82 8

7.94 18 P 1 ORS UTE

-0.82 UTE UTE SLV 1004 INLET 400PS 82 9

5.79 17 P 1 ORS UTE

-0.74 UTE UTE SLV 1004 INLET 400PS

1. 55 36 2

SVI 013

+0.80 013 013 4038 OUTLET 460SI 2.64 40 P 3 TWO 36 013

+0.80 013 013 4038 OUTLET 460SI 82 17 0.10 84 2

VOL 014

+1.01 014 014 4092 OUTLET 460S1 82 19

1. 98 200 1 ONT LTE

+11.21 LTE LTE 4092 OUTLET 460SI 3.38 183 1 ONT LTE

+11.57 LTE LTE 4092 OUTLET 460SI 82 22 2.17 21 2

TEA UTE

-0.11 UTE UTE 2121 INLET 460HR 82 29

1. 27 21 2

TEA UTE

-0.20 UTE UTE 2120 INLET 460HR 82 30 2.69 21 2

TEA UTE

-0.24 UTE UTE 2121 INLET 460HR 82 35 1.10 39 2

MAl UTE

-3.47 UTE UTS 2120 INLET 460HR 1.10 39 2

TWO 98 UTE

-3.47 UTE UTS 2120 INLET 460HR 82 36 0.63 37 2

TEA UTE

-0.17 UTE UTE 2121 INLET 460HR 82 37 3.00 21 2

TEA UTE

-0.18 UTE UTE 2120 INLET 460HR 82 38 2.15 17 2

TEA UTE

-0.22 UTE UTE 2121 INLET 460HR 82 48 2.79 24 2

TEA UTE

-0.14 UTE UTE 2121 INLET 460HR 82 63 2.30 180 1 ONT UTS

-0.11 UTS UTS 4005 OUTLET 460S1 82 64 6.35 172 1 ONT LTE

+8.70 LTE LTE 4005 OUTLET 460S1 0.47 0

P 3 TWO 12 008

+0.75 008 008 WAR 4005 OUTLET 460S1 82 65 2.65 27 2

TEA UTE

-0.12 UTE UTE 2008 INLET 460HR 82 70 5.73 28 2

TEA UTE

-0.15 UTE UTE 2007 INLET 460HR 82 74 5.56 27 2

TEA UTE

-0.17 UTE UTE 2007 INLET 460HR 82 75 2.57 36 2

TEA UTE

-0.07 UTE UTE 2008 INLET 460HR 82 81

1. 28 42 2

TEA UTE

-0.26 UTE UTE 2017 INLET 460HR 82 82 6.45 27 2

TEA UTE

-0.15 UTE UTE 2018 INLET 460HR 82 84 0.00 0

P 3 TWO 0 UTE

-0.l3 TO+264.3 UTE UTS 2018 INLET 460HR 2.69 20 P 3 TWO 61 UTE

-0.13 TO+273.4 UTE UTS 2018 INLET 460HR 3.61 27 P 3 TWO 75 UTE

-0.13 TO+282.5 UTE UTS 2018 INLET 460HR 3.50 21 P 1 SCI UTE

-0.13 UTE UTS CL 2018 INLET 460HR 4.31 32 P 3 TWO 84 UTE

-0.13 TO+300.8 UTE UTS 2018 INLET 460HR 4.00 37 P 3 TWO 80 UTE

-0.13 TO+291. 6 UTE UTS 2018 INLET 460HR 3.92 26 P 3 TWO 79 UTE

-0.13 TO+309.9 UTE UTS 2018 INLET 460HR 3.52 20 P 3 TWO 74 UTE

-0.13 TO+319.0 UTE UTS 2018 INLET 460HR 2.21 16 P 3 TWO 52 UTE

-0.13 TO+328.1 UTE UTS 2018 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.13 TO+337.2 UTE UTS 2018 INLET 460HR 82 85 2.34 18 2

TEA UTE

-0.17 UTE UTE 2017 INLET 460HR 82 92 1.50 22 2

TEA UTE

-0.17 UTE UTE 2018 INLET 460HR 82 93 0.86 23 2

TEA UTE

-0.21 UTE UTE 2017 INLET 460HR 82 94 2.54 17 2

TEA UTE

-0.19 UTE UTE 2018 INLET 460HR 82 95

1. 04 28 2

TEA UTE

-0.16 UTE UTE 2017 INLET 460HR 82 96 3.33 27 2

TEA UTE

-0.14 UTE UTE 2018 INLET 460HR 82 98 3.44 23 2

TEA UTE

-0.17 UTE UTE 2018 INLET 460HR

Framatome ANP Inc.

05/02/02 13:29:49 Customer Name: Oconee Unit 1 Component: S/G B Page 89 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -- MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

82 102 4.39 21 2

TEA UTE

-0.16 UTE UTE 2018 INLET 460HR 82 105 0.83 26 2

TEA UTE

-0.21 UTE UTE 2017 INLET 460HR 82 107 2.86 21 2

TEA UTE

-0.12 UTE UTE 2017 INLET 460HR 82 115 1.87 23 2

TEA UTE

-0.15 UTE UTE 2071 INLET 460HR 6.44 174 1 DNT LTE

+10.91 LTE LTE 4039 OUTLET 460SI 0.14 73 2

VOL 014

+0.87 014 014 4039 OUTLET 460SI 82 116 4.17 25 2

TEA UTE

-0.22 UTE UTE 2072 INLET 460HR 9.47 174 1 DNT LTE

+11.04 LTE LTE 4039 OUTLET 460S1 6.78 183 1 DNT UTE

-9.62 UTE UTE 4039 OUTLET 460S1 82 118 0.44 95 P 3 TWD 13 009

+0.66 009 009 WAR 4043 OUTLET 460S1 1.15 37 2

TEA UTE

-0.16 UTE UTE 2071 INLET 460HR 82 120 1.15 59 2

TEA UTE

-0.06 UTE UTE 2071 INLET 460HR 82 121 2.70 26 2

TEA UTE

-0.16 UTE UTE 2072 INLET 460HR 82 122 2.79 25 2

TEA UTE

-0.14 UTE UTE 2071 INLET 460HR 82 123 5.15 28 2

TEA UTE

-0.19 UTE UTE 2072 INLET 460HR 82 124 0.41 65 2

VOL 014

+0.68 014 014 4043 OUTLET 460S1 0.22 77 2

VOL 014

+0.42 014 014 4043 OUTLET 460SI 0.17 59 2

VOL 014

+1. 28 014 014 4043 OUTLET 460SI 4.65 31 2

TEA UTE

-0.19 UTE UTE 2071 INLET 460HR 83 2

2.61 18 P 1 VOL UTE

-0.77 UTE UTE SLV 1004 INLET 400PS 83 4

1.87 22 P 2 DRS UTE

-0.70 UTE UTE SLV 1004 INLET 400PS 83 5

7.32 21 P 1 DRS UTE

-0.69 UTE UTE SLV 1004 INLET 400PS 83 6

0.17 142 P 3 TWD 3 013

+0.84 013 013 WAR 4038 OUTLET 460SI 83 8

4.10 22 P 1 DRS UTE

-0.76 UTE UTE SLV 1004 INLET 400PS 83 9

1.14 18 P 1 DRS 015

-5.55 015 015 SLV 1004 INLET 400PS 83 12 0.32 44 P 3 TWD 9 008

+0.74 008 008 WAR 4091 OUTLET 460S1 83 19

1. 88 189 1 DNT LTS

-2.80 LTS LTS 4092 OUTLET 460SI

1. 99 182 1 DNT LTS

-3.81 LTS LTS 4092 OUTLET 460SI

1. 54 181 1 DNT LTS

-4.87 LTS LTS 4092 OUTLET 460SI 83 20 2.34 18 2

TEA UTE

-0.18 UTE UTE 2121 INLET 460HR 83 22

1. 66 14 2

TEA UTE

-0.19 UTE UTE 2121 INLET 460HR 83 25 3.08 16 2

TEA UTE

-0.12 UTE UTE 2120 INLET 460HR 83 26 0.97 31 2

TEA UTE

-0.21 UTE UTE 2121 INLET 460HR 83 32 2.45 19 2

TEA UTE

-0.23 UTE UTE 2121 INLET 460HR 83 34 2.63 21 2

TEA UTE

-0.25 UTE UTE 2121 INLET 460HR 83 35 3.31 25 2

TEA UTE

-0.18 UTE UTE 2120 INLET 460HR 83 39 3.49 23 2

TEA UTE

-0.27 UTE UTE 2120 INLET 460HR 83 40 4.96 169 1 DNT UTS

-3.23 UTS UTS 4104 OUTLET 460S1 3.16 170 1 DNT UTS

-4.23 UTS UTS 4104 OUTLET 460S1 3.26 169 1 DNT UTS

-9.09 UTS UTS 4104 OUTLET 460S1 2.74 168 1 DNT UTS

-10.21 UTS UTS 4104 OUTLET 460S1

1. 30 172 1 DNT UTS

-21.74 UTS UTS 4104 OUTLET 460S1 3.00 159 1 DNT UTS

-22.64 UTS UTS 4104 OUTLET 460S1 2.15 160 1 DNT UTE

-2.43 UTE UTE 4104 OUTLET 460S1 83 41 0.90 19 2

TEA UTE

-0.27 UTE UTE 2120 INLET 460HR 83 44 0.56 19 2

TWO 53 UTE

-1. 32 UTE UTE 2121 INLET 460HR 0.46 20 2

SAl UTE

-1. 32 UTE UTE CS 2121 INLET 460HR 83 48 3.81 28 2

TEA UTE

-0.15 UTE UTE 2121 INLET 460HR 83 53 2.02 31 2

TEA UTE

-0.16 UTE UTE 2120 INLET 460HR 83 55 1.97 166 1 DNT LTS

-0.02 LTS LTS 4104 OUTLET 460S1 83 61

1. 26 196 1 DNT UTS

+4.09 UTS UTS 4003 INLET 460S1 2.03 186 1 DNT UTS

+5.34 UTS UTS 4003 INLET 460S1 3.20 180 1 ONT UTS

+7.66 UTS UTS 4003 INLET 460S1 83 71 3.41 24 2

TEA UTE

-0.14 UTE UTE IDOK 2013 INLET 460HR 3.85 26 2

TEA UTE

-0.22 UTE UTE 2007 INLET 460HR 83 72 0.04 69 2

VOL 006

+3.82 007 006 4004 INLET 460SI 83 73 1.51 180 1 DNT UTS

+13.70 UTE UTS 4004 INLET 460SI 2.94 178 1 DNT UTS

+15.04 UTE UTS 4004 INLET 460SI 2.62 169 1 DNT UTS

+16.42 UTE UTS 4004 INLET 460SI 83 78 0.69 23 2

TEA UTE

-0.23 UTE UTE 2021 INLET 460HR 83 80

1. 49 14 2

TEA UTE

-0.20 UTE UTE 2021 INLET 460HR 83 81

1. 55 19 2

TEA UTE

-0.16 UTE UTE 2022 INLET 460HR 83 83 3.78 28 2

TEA UTE

-0.16 UTE UTE 2022 INLET 460HR 83 92

1. 57 22 2

TEA UTE

-0.15 UTE UTE 2021 INLET 460HR 83 94

1. 38 48 2

TEA UTE

-0.22 UTE UTE 2021 INLET 460HR 83 96 1.34 30 P 1 SCI UTE

-0.20 UTE UTE CL 2021 INLET 460HR 0.37 53 P 3 TWD 45 UTE

-0.20 TO+147.5 UTE UTE 2021 INLET 460HR 0.51 53 P 3 TWO 64 UTE

-0.20 TO+156.1 UTE UTE 2021 INLET 460HR 0.71 45 P 3 TWD 92 UTE

-0.20 TO+164.8 UTE UTE 2021 INLET 460HR 0.69 40 P 3 TWO 89 UTE

-0.20 TO+173.5 UTE UTE 2021 INLET 460HR 0.59 40 P 3 TWD 76 UTE

-0.20 TO+182.2 UTE UTE 2021 INLET 460HR 0.48.

41 P 3 TWD 59 UTE

-0.20 TO+190.8 UTE UTE 2021 INLET 460HR 0.38 41 P 3 TWD 46 UTE

-0.20 TO+199.5 UTE UTE 2021 INLET 460HR 0.15 60 P 3 TWD 18 UTE

-0.20 TO+208.2 UTE UTE 2021 INLET 460HR 0.13 38 P 3 TWD 16 UTE

-0.20 TO+216.9 UTE UTE 2021 INLET 460HR

Framatome ANP Inc.

05/02/02 13:29:50 Customer Name: Oconee Unit 1 Component: S/G B Page 90 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

0.14 47 P 3 TWD 17 UTE

-0.20 TO+225.5 UTE UTE 2021 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.20 TO+234.2 UTE UTE 2021 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.20 TO+138.8 UTE UTE 2021 INLET 460HR 83 98 0.93 18 2

TEA UTE

-0.19 UTE UTE 2021 INLET 460HR 83 100 3.06 27 2

TEA UTE

-0.19 UTE UTE 2021 INLET 460HR 83 101 4.42 26 2

TEA UTE

-0.18 UTE UTE 2022 INLET 460HR 83 104

1. 44 19 2

TEA UTE

-0.20 UTE UTE 2017 INLET 460HR 83 106 3.23 22 2

TEA UTE

-0.18 UTE UTE 2017 INLET 460HR 83 107 3.20 22 2

TEA UTE

-0.18 UTE UTE 2018 INLET 460HR 83 108

1. 38 31 2

TEA UTE

-0.23 UTE UTE 2017 INLET 460HR 83 109 1.27 20 2

TEA UTE

-0.20 UTE UTE 2018 INLET 460HR 83 110 3.40 26 2

TEA UTE

-0.22 UTE UTE 2017 INLET 460HR 83 114 0.14 66 2

VOL 013

+1.06 013 013 4039 OUTLET 460SI 83 118 7.68 175 1 DNT LTE

+11.33 LTE LTE 4039 OUTLET 460S1 0.16 113 2 VOL 014

+0.79 014 014 4039 OUTLET 460SI 83 121 0.41 71 P 3 TWO 12 008

-0.54 008 008 WAR 4043 OUTLET 460SI 0.42 95 P 3 TWO 12 014

+0.64 014 014 WAR 4043 OUTLET 460SI 1.25 25 2

TEA UTE

-0.15 UTE UTE 2072 INLET 460HR 83 123 3.07 24 2

TEA UTE

-0.15 UTE UTE 2072 INLET 460HR 83 125 3.31 31 2

TEA UTE

-0.16 UTE UTE 2071 INLET 460HR 83 126 0.10 85 2

VOL 014

+0.85 014 014 4043 OUTLET 460SI 0.72 44 P 1 SCI UTE

-0.22 UTE UTE CL 2071 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.22 TO+162.0 UTE UTE 2071 INLET 460HR 0.16 5

P 3 TWO 19 UTE

-0.22 TO+17 1. 0 UTE UTE 2071 INLET 460HR 0.25 203 P 3 TWO 31 UTE

-0.22 TO+180.0 UTE UTE 2071 INLET 460HR 0.24 36 P 3 TWO 29 UTE

-0.22 TO+189.0 UTE UTE 2071 INLET 460HR 0.35 37 P 3 TWO 43 UTE

-0.22 TO+198.0 UTE UTE 2071 INLET 460HR 0.51 39 P 3 TWD 63 UTE

-0.22 TO+207.0 UTE UTE 2071 INLET 460HR 0.80 38 P 3 TWD 98 UTE

-0.22 TO+216.0 UTE UTE 2071 INLET 460HR 0.65 43 P 3 TWD 80 UTE

-0.22 TO+225.0 UTE UTE 2071 INLET 460HR 0.22 80 P 3 TWO 27 UTE

-0.22 TO+234.0 UTE UTE 2071 INLET 460HR 0.13 10 P 3 TWO 15 UTE

-0.22 TO+243.0 UTE UTE 2071 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.22 TO+252.0 UTE UTE 2071 INLET 460HR 83 127 2.76 21 2

TEA UTE

-0.17 UTE UTE 2072 INLET 460HR 0.37 92 2

VOL 008

+0.42 008 008 4049 OUTLET 460SI 83 131 4.20 31 2

TEA UTE

-0.22 UTE UTE 2071 INLET 460HR 5.16 172 1 ONT LTE

+11. 98 LTE LTE 4049 OUTLET 460SI 0.11 84 2

VOL 013

+1.05 013 013 4049 OUTLET 460SI 8.45 353 1 DNT UTE

-11.53 UTE UTE 4049 OUTLET 460S1 7.30 349 1 DNT UTE

-11.70 UTE UTE 4049 OUTLET 460SI 83 132 4.15 24 2

TEA UTE

-0.18 UTE UTE 2072 INLET 460HR 6.09 180 1 DNT LTE

+11.51 LTE LTE 4049 OUTLET 460SI 0.37 56 P 3 TWD 14 012

-0.62 012 012 WAR 4049 OUTLET 460SI 5.76 177 1 ONT UTE

-11.56 UTE UTE 4049 OUTLET 460S1 84 8

2.55 29 2

TEA UTE

-0.09 UTE UTE 2121 INLET 460HR 84 10 2.09 17 2

TEA UTE

-0.10 UTE UTE 2121 INLET 460HR 84 12 0.09 67 2

VOL 012

+1.05 012 012 4092 OUTLET 460SI 84 13 0.17 66 2

SAl 015

+4.33 015 015 4092 OUTLET 460SI 0.17 66 2

TWD 58 015

+4.33 015 015 4092 OUTLET 460SI 0.16 65 2

SAl 015

+4.21 015 015 4092 OUTLET 460SI 0.16 65 2

TWD 61 015

+4.21 015 015 4092 OUTLET 460S1 0.11 63 2

SAl 015

+3.86 015 015 4092 OUTLET 460S1 0.11 63 2

TWD 67 015

+3.86 015 015 4092 OUTLET 460SI 84 14 0.20 53 P 3 TWO 5 008

+0.44 008 008 WAR 4092 OUTLET 460S1 1.96 21 2

TEA UTE

-0.13 UTE UTE 2121 INLET 460HR 84 17 2.86 27 2

TEA UTE

-0.18 UTE UTE 2120 INLET 460HR 84 18 3.52 181 1 DNT 002

+1. 43 002 002 4092 OUTLET 460S1 84 25 2.10 25 2

TEA UTE

-0.15 UTE UTE 2120 INLET 460HR 84 32 2.54 22 P 1 SCI UTE

-0.55 UTE UTS TR 2121 INLET 460HR 1.23 38 P 3 TWO 0 UTE

-0.55 TO+275.6 UTE UTS 2121 INLET 460HR

1. 76 32 P 3 TWD 86 UTE

-0.55 TO+266.7 UTE UTS 2121 INLET 460HR 2.06 32 P 3 TWD 93 UTE

-0.55 TO+257.8 UTE UTS 2121 INLET 460HR 2.34 30 P 3 TWD 99 UTE

-0.55 TO+248.9 UTE UTS 2121 INLET 460HR 2.34 28 P 3 TWD 99 UTE

-0.55 TO+240.0 UTE UTS 2121 INLET 460HR 2.26 29 P 3 TWO 97 UTE

-0.55 TO+231.1 UTE UTS 2121 INLET 460HR 2.12 27 P 3 TWO 94 UTE

-0.55 TO+222.2 UTE UTS 2121 INLET 460HR

1. 95 27 P 3 TWO 90 UTE

-0.55 TO+213.3 UTE UTS 2121 INLET 460HR 2.14 26 P 3 TWO 95 UTE

-0.55 TO+204.4 UTE UTS 2121 INLET 460HR 2.29 26 P 3 TWO 98 UTE

-0.55 TO+195.6 UTE UTS 2121 INLET 460HR 1.66 30 P 3 TWD 83 UTE

-0.55 TO+186.7 UTE UTS 2121 INLET 460HR 1.14 42 P 3 TWD 0 UTE

-0.55 TO+177.8 UTE UTS 2121 INLET 460HR 84 35

1. 91 23 2

TEA UTE

-0.21 UTE UTE 2120 INLET 460HR 84 36 4.91 23 2

TEA UTE

-0.06 UTE UTE 2121 INLET 460HR 84 37

1. 70 29 2

TEA UTE

-0.24 UTE UTE 2120 INLET 460HR 84 38 2.85 23 2

TEA UTE

-0.18 UTE UTE 2121 INLET 460HR

Framatome ANP Inc.

05/02/02 13:29:51 Customer Name: Oconee Unit 1 Component: S/G B Page 91 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -_ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

84 39 0.68 22 2

SAl UTE

-3.44 UTE UTS 2120 INLET 460HR 0.68 22 2

TWO 60 UTE

-3.44 UTE UTS 2120 INLET 460HR 84 47 4.70 27 2

TEA UTE

-0.14 UTE UTE 2120 INLET 460HR 84 51

1. 49 21 2

TEA UTE

-0.25 UTE UTE 2120 INLET 460HR 84 60 3.13 17 2

TEA UTE

-0.15 UTE UTE 2008 INLET 460HR 84 61

1. 69 23 2

SAl UTE

-3.57 UTE UTS TR 2007 INLET 460HR

1. 69 23 2

TWO 66 UTE

-3.57 UTE UTS 2007 INLET 460HR 84 65 1.29 182 1 DNT LTS

+3.04 LTS LTS 4005 OUTLET 460S1 3.21 170 1 DNT LTS

-16.74 LTS LTS 4005 OUTLET 460S1 84 67

1. 63 25 2

TEA UTE

-0.22 UTE UTE 2007 INLET 460HR 84 72 2.39 32 2

TEA UTE

-0.10 UTE UTE 2008 INLET 460HR 84 75

1. 89 42 2

TEA UTE

-0.18 UTE UTE 2007 INLET 460HR 84 76 4.71 23 2

TEA UTE

-0.18 UTE UTE 2007 INLET 460HR 84 79 1.47 32 2

TEA UTE

-0.22 UTE UTE 2021 INLET 460HR 84 80 2.01 25 2

TEA UTE

-0.12 UTE UTE 2022 INLET 460HR 84 82 2.01 17 2

TEA UTE

-0.11 UTE UTE 2022 INLET 460HR 84 83 2.10 20 2

TEA UTE

-0.15 UTE UTE 2021 INLET 460HR 84 85 4.06 176 1 DNT 014

-17.39 014 014 4033 OUTLET 460SI

1. 61 26 2

TEA UTE

-0.22 UTE UTE 2021 INLET 460HR 84 87 2.63 174 1 DNT LTS

-9.46 LTS LTS 4033 OUTLET 460S1 84 89 0.97 29 2

TEA UTE

-0.24 UTE UTE 2021 INLET 460HR 84 91 0.87 27 2

TEA UTE

-0.21 UTE UTE 2021 INLET 460HR 84 92 1.10 25 2

TEA UTE

-0.13 UTE UTE 2022 INLET 460HR 84 93

1. 97 22 2

TEA UTE

-0.23 UTE UTE 2021 INLET 460HR 84 95 0.61 49 2

TEA UTE

-0.23 UTE UTE 2021 INLET 460HR 84 97

1. 45 28 2

TEA UTE

-0.20 UTE UTE 2021 INLET 460HR 84 98 4.11 36 2

TEA UTE

-0.14 UTE UTE 2022 INLET 460HR 84 99 0.61 32 2

TEA UTE

-0.32 UTE UTE 2021 INLET 460HR 84 101 2.77 15 2

TEA UTE

-0.19 UTE UTE 2021 INLET 460HR 84 102 3.53 20 2

TEA UTE

-0.14 UTE UTE 2022 INLET 460HR 84 103 0.69 43 2

TEA UTE

-0.26 UTE UTE 2021 INLET 460HR 84 104

1. 37 11 2

TEA UTE

-0.20 UTE UTE 2022 INLET 460HR 84 105

1. 58 32 2

TEA UTE

-0.29 UTE UTE 2021 INLET 460HR 84 106 0.94 29 2

TEA UTE

-0.25 UTE UTE 2022 INLET 460HR 84 108 4.88 24 2

TEA UTE

-0.21 UTE UTE 2022 INLET 460HR 84 109 2.58 17 2

TEA UTE

-0.09 UTE UTE 2021 INLET 460HR 84 110 2.50 20 2

TEA UTE

-0.16 UTE UTE 2022 INLET 460HR 84 112

1. 77 24 2

TEA UTE

-0.21 UTE UTE 2072 INLET 460HR 84 113 3.40 32 2

TEA UTE

-0.16 UTE UTE 2071 INLET 460HR 84 114 2.44 24 2

TEA UTE

-0.17 UTE UTE 2072 INLET 460HR 0.18 54 2

VOL 013

+0.81 013 013 4039 OUTLET 460S1 84 115 2.10 30 2

TEA UTE

-0.08 UTE UTE 2071 INLET 460HR 0.34 144 2 VOL 014

+0.73 014 014 4039 OUTLET 460S1 84 116 2.60 26 2

TEA UTE

-0.22 UTE UTE 2072 INLET 460HR 6.45 173 1 DNT LTE

+11.49 LTE LTE 4039 OUTLET 460SI 84 117 4.07 32 2

TEA UTE

-0.13 UTE UTE 2071 INLET 460HR 7.38 169 1 DNT LTE

+10.96 LTE LTE 4039 OUTLET 460SI 84 119 0.41 63 P 3 TWO 11 010

-0.58 010 010 WAR 4039 OUTLET 460SI 84 121 3.13 28 2

TEA UTE

-0.14 UTE UTE 2124 INLET 460HR 84 122 0.18 78 2

VOL 013

+1.09 013 013 4043 OUTLET 460S1 84 123 0.22 64 2

VOL 013

+0.67 013 013 4043 OUTLET 460SI 0.11 88 2

VOL 014

+0.95 014 014 4043 OUTLET 460SI 3.64 32 2

TEA UTE

-0.15 UTE UTE 2071 INLET 460HR 84 130

1. 43 18 2

TEA UTE

-0.17 UTE UTE 2072 INLET 460HR 5.80 173 1 DNT LTE

+11. 56 LTE LTE 4049 OUTLET 460SI 0.25 59 P 3 TWD 10 010

+0.68 010 010 WAR 4049 OUTLET 460SI 6.57 174 1 DNT UTE

-10.06 UTE UTE 4049 OUTLET 460SI 85 2

66.75 4

1 SCI LTE

+0.69 LTE LTE 708 OUTLET 380EX 85 4

0.20 62 2

VOL 014

+1. 45 014 014 4038 OUTLET 460SI 0.12 68 2

VOL 014

+1. 29 014 014 4038 OUTLET 460SI 85 8

0.20 58 P 3 TWD 5 009

+0.56 009 009 WAR 4092 OUTLET 460SI 2.85 18 2

TEA UTE

-0.10 UTE UTE 2121 INLET 460HR 85 10 0.43 50 P 3 TWD 11 008

+0.61 008 008 WAR 4092 OUTLET 460SI

1. 93 28 2

TEA UTE

-0.08 UTE UTE 2121 INLET 460HR 85 11 0.25 111 P 3 TWO 6 010

+0.48 010 010 WAR 4092 OUTLET 460S1 2.17 28 2

TEA UTE

-0.17 UTE UTE 2120 INLET 460HR 85 12 0.39 131 P 3 TWO 10 009

-0.74 009 009 WAR 4092 OUTLET 460SI 2.10 19 2

TEA UTE

-0.09 UTE UTE 2121 INLET 460HR 85 14 0.43 81 P 3 TWD 11 008

+0.71 008 008 WAR 4092 OUTLET 460SI 85 17 3.81 184 1 DNT LTS

-13.45 LTS LTS 4092 OUTLET 460SI

1. 85 88 1

VOL LTS

+14.95 TO+19.99 LTS LTS 4092 OUTLET 460SI 5.38 182 1 DNT UTE

-11. 56 UTE UTE 4092 OUTLET 460SI 85 18 3.46 184 1 DNT LTE

+10.72 LTE LTE 4092 OUTLET 460SI 7.54 180 1 DNT UTE

-11.85 UTE UTE 4092 OUTLET 460SI 85 22 1.37 20 2

TEA UTE

-0.12 UTE UTE 2121 INLET 460HR

Framatome ANP Inc.

05/02/02 13:29:52 Customer Name: Oconee Unit 1 Component: S/G B Page 92 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

85 23 0.29 140 P 3 TWO 7 008

-0.39 008 008 WAR 4092 OUTLET 460S1 85 28 3.24 22 2

TEA UTE

-0.11 UTE UTE 2121 INLET 460HR 85 34 2.72 29 2

TEA UTE

-0.17 UTE UTE 2120 INLET 460HR 85 35 2.85 23 2

TEA UTE

-0.12 UTE UTE 2121 INLET 460HR 85 39 5.50 175 1 DNT LTS

+8.00 LTS LTS 4104 OUTLET 460S1 2.38 20 2

TEA UTE

-0.12 UTE UTE 2121 INLET 460HR 85 42 2.92 29 2

TEA UTE

-0.20 UTE UTE 2120 INLET 460HR 85 46 1.79 26 2

TEA UTE

-0.29 UTE UTE 2120 INLET 460HR 85 48 1.71 35 2

TEA UTE

-0.21 UTE UTE 2120 INLET 460HR 85 49 4.01 27 2

TEA UTE

-0.20 UTE UTE 2121 INLET 460HR 85 61 1.90 20 2

TEA UTE

-0.22 UTE UTE 2007 INLET 460HR 85 62 0.15 74 2

SAl UTS

-12.19 UTS UTS 4005 OUTLET 460S1 0.15 74 2

TWD 62 UTS

-12.19 UTS UTS 4005 OUTLET 460S1 85 63 2.18 166 1 DNT LTE

+7.26 LTE LTE 4005 OUTLET 460S1 2.80 167 1 ONT LTE

+8.12 LTE LTE 4005 OUTLET 460SI 85 68 2.08 22 2

TEA UTE

-0.25 UTE UTE 2013 INLET 460HR 85 73 3.48 20 2

TEA UTE

-0.19 UTE" UTE 2007 INLET 460HR 85 78 0.57 44 2

TEA UTE

-0.17 UTE UTE 2021 INLET 460HR 85 81 2.31 22 2

TEA UTE

-0.15 UTE UTE 2022 INLET 460HR 85 82 0.37 18 2

TEA UTE

-0.21 UTE UTE 2021 INLET 460HR 85 84 2.25 30 2

TEA UTE

-0.10 UTE UTE 2021 INLET 460HR 85 87 6.23 20 2

TEA UTE

-0.14 UTE UTE 2022 INLET 460HR 85 93 1.02 22 2

TEA UTE

-0.22 UTE UTE 2021 INLET 460HR 85 94 2.90 20 2

TEA UTE

-0.10 UTE UTE 2022 INLET 460HR 85 96 0.90 16 2

SAl UTE

-3.48 UTE UTS TR 2022 INLET 460HR 0.90 16 2

TWO 44 UTE

-3.48 UTE UTS 2022 INLET 460HR 85 98

1. 90 18 2

TEA UTE

-0.20 UTE UTE 2021 INLET 460HR 85 99 5.12 24 2

TEA UTE

-0.16 UTE UTE 2022 INLET 460HR 85 100 0.84 27 2

TEA UTE

-0.21 UTE UTE 2021 INLET 460HR 1.00 16 2

TWO 41 UTE

-2.53 UTE UTE 2021 INLET 460HR 1.00 16 2

SVI UTE

-2.53 UTE UTE CS 2021 INLET 460HR 85 101 0.72 20 P 1 SCI UTE

-3.74 UTE UTS TR 2022 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.74 TO+223.3 UTE UTS 2022 INLET 460HR 0.19 23 P 3 TWO 3 UTE

-3.74 TO+214.2 UTE UTS 2022 INLET 460HR 0.34 17 P 3 TWO 18 UTE

-3.74 TO+205.1 UTE UTS 2022 INLET 460HR 0.27 11 P 3 TWO 8 UTE

-3.74 TO+195.9 UTE UTS 2022 INLET 460HR 0.26 22 P 3 TWO 7 UTE

-3.74 TO+186.8 UTE UTS 2022 INLET 460HR 0.51 29 P 3 TWO 88 UTE

-3.74 TO+177.7 UTE UTS 2022 INLET 460HR 0.45 31 P 3 TWO 50 UTE

-3.74 TO+168.6 UTE UTS 2022 INLET 460HR 0.46 31 P 3 TWO 54 UTE

-3.74 TO+159.5 UTE UTS 2022 INLET 460HR 0.35 32 P 3 TWO 20 UTE

-3.74 TO+150.4 UTE UTS 2022 INLET 460HR 0.24 23 P 3 TWO 5 UTE

-3.74 T0+141. 3 UTE UTS 2022 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.74 TO+132.2 UTE UTS 2022 INLET 460HR 85 102 0.72 49 2

TEA UTE

-0.18 UTE UTE 2021 INLET 460HR 85 103 2.47 20 2

TEA UTE

-0.16 UTE UTE 2022 INLET 460HR 85 106

1. 46 28 2

TEA UTE

-0.24 UTE UTE 2021 INLET 460HR 85 107 5.90 27 2

TEA UTE

-0.17 UTE UTE 2022 INLET 460HR 85 108 2.77 40 2

TEA UTE

-0.17 UTE UTE 2021 INLET 460HR 85 109 2.82 23 2

TEA UTE

-0.09 UTE UTE 2022 INLET 460HR 85 112 4.20 29 2

TEA UTE

-0.15 UTE UTE 2071 INLET 460HR 85 113 5.13 25 2

TEA UTE

-0.15 UTE UTE 2072 INLET 460HR 85 115 4.54 23 2

TEA UTE

-0.18 UTE UTE 2072 INLET 460HR 85 116 2.33 28 2

TEA UTE

-0.17 UTE UTE 2071 INLET 460HR 85 117 2.90 26 2

TEA UTE

-0.18 UTE UTE 2072 INLET 460HR 85 118 3.65 29 2

TEA UTE

-0.18 UTE UTE 2071 INLET 460HR 85 119 2.36 20 2

TEA UTE

-0.19 UTE UTE 2072 INLET 460HR 85 123 4.78 24 2

TEA UTE

-0.20 UTE UTE 2072 INLET 460HR 85 129 0.15 60 2

VOL 012

+1.36 012 012 4049 OUTLET 460SI 5.05 31 2

TEA UTE

-0.23 UTE UTE 2124 INLET 460HR 85 130

1. 04 89 2

VOL 010

+0.38 010 010 4049 OUTLET 460S1 86 2

9.02 25 P 1 ORS UTE

-0.87 UTE UTE SLY 1004 INLET 400PS

1. 01 86 P 1 VOL UTE

-1. 27 UTE UTE SLY 1004 INLET 400PS 7.13 183 1 ONT LTE

+10.41 LTE LTE 4038 OUTLET 460S1 5.90 178 1 ONT LTE

+11.02 LTE LTE 4038 OUTLET 460SI 0.14 86 2

VOL 014

+1.35 014 014 4038 OUTLET 460SI 86 3

5.26 17 P 1 ORS UTE

-0.88 UTE UTE SLY 1004 INLET 400PS 5.97 180 1 ONT LTS

-13.82 LTS LTS 4038 OUTLET 460SI 0.63 135 P 3 TWO 11 014

+0.75 014 014 WAR 4038 OUTLET 460S1 86 5

5.86 22 P 1 DRS UTE

-0.64 UTE UTE SLY 1004 INLET 400PS 86 6

7.64 176 1 ONT LTE

+11.16 LTE LTE 4092 OUTLET 460SI 0.36 70 P 3 TWO 9 010

+0.37 010 010 WAR 4092 OUTLET 460S1 3.32 174 1 DNT UTE

-11. 74 UTE UTE 4092 OUTLET 460S1 3.78 28 2

TEA UTE

-0.11 UTE UTE 2121 INLET 460HR 86 7

2.48 177 1 DNT LTE

+11.27 LTE LTE 4092 OUTLET 460S1 5.41 173 1 DNT UTE

-11. 92 UTE UTE 4092 OUTLET 460SI

Framatome ANP Inc.

05/02/02 13:29:53 Customer Name: Oconee Unit 1 Component: S/G B Page 93 of 155 ATTACHMENT #4 - LIST OF IMPERFECTIONS -, MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===
1. 40 26 2

TEA UTE

-0.20 UTE UTE 2120 INLET 460HR 86 8

1. 36 21 2

TEA UTE

-0.11 UTE UTE 2121 INLET 460HR 86 9

1. 86 27 2

TEA UTE

-0.16 UTE UTE 2120 INLET 460HR 86 11 3.79 25 2

TEA UTE

-0.24 UTE UTE 2120 INLET 460HR 86 13

1. 43 28 2

TEA UTE

-0.16 UTE UTE 2120 INLET 460HR 86 14 2.49 28 2

TEA UTE

-0.13 UTE UTE 2120 INLET 460HR 86 15 0.29 67 2

VOL 012

+0.73 012 012 4092 OUTLET 460SI 86 17 6.10 180 1 DNT LTE

+10.85 LTE LTE 4092 OUTLET 460SI 4.87 184 1 DNT UTE

-11.16 UTE UTE 4092 OUTLET 460SI 4.67 180 1 DNT UTE

-11.60 UTE UTE 4092 OUTLET 460S1 1.09 19 2

TEA UTE

-0.09 UTE UTE 2121 INLET 460HR 86 18 30.96 12 1

SCI LTE

+0.82 LTE LTE 708 OUTLET 380EX 86 19 5.39 180 1 DNT LTE

+10.73 LTE LTE 4092 OUTLET 460SI 6.30 183 1 DNT UTE

-11.75 UTE UTE 4092 OUTLET 460SI 86 21 3.03 20 2

TEA UTE

-0.13 UTE UTE 2121 INLET 460HR 86 26 2.40 26 2

TEA UTE

-0.23 UTE UTE 2120 INLET 460HR 86 29 3.63 24 2

TEA UTE

-0.10 UTE UTE 2121 INLET 460HR 86 30

1. 95 33 2

TEA UTE

-0.16 UTE UTE 2120 INLET 460HR 86 33 2.74 28 2

TEA UTE

-0.06 UTE UTE 2121 INLET 460HR 86 41 0.74 24 2

SAl UTE

-3.50 UTE UTS 2121 INLET 460HR 0.74 24 2

TWD 74 UTE

-3.50 UTE UTS 2121 INLET 460HR 86 42 4.'00 30 2

TEA UTE

-0.23 UTE UTE 2120 INLET 460HR 86 44 0.51 21 2

TEA UTE

-0.26 UTE UTE 2120 INLET 460HR 86 49 3.25 22 2

TEA UTE

-0.16 UTE UTS 2121 INLET 460HR 86 59 2.33 179 1 DNT 009

-13.47 009 009 4003 INLET 460SI 86 60 2.53 173 1 DNT UTS

+8.78 UTS UTS 4003 INLET 460SI 86 61 0.70 24 2

SVI UTE

-0.95 UTE UTE TR 2008 INLET 460HR 0.70 24 2

TWD 75 UTE

-0.95 UTE UTE 2008 INLET 460HR 86 70 5.97 186 1 DNT 012

+12.20 012 012 4003 INLET 460S1 86 71 3.35 201 2 TEA UTE

-0.32 UTE UTE 2008 INLET 460HR 86 82 0.45 37 2

TEA UTE

-0.21 UTE UTE 2021 INLET 460HR 86 84 0.74 28 2

TEA UTE

-0.21 UTE UTE 2021 INLET 460HR 86 85 3.33 23 2

TEA UTE

-0.24 UTE UTE 2022 INLET 460HR 86 89 2.77 27 2

TEA UTE

-0.18 UTE UTE 2022 INLET 460HR 86 90

1. 37 33 2

TEA UTE

-0.22 UTE UTE 2021 INLET 460HR 86 94 2.31 30 2

TEA UTE

-0.21 UTE UTE 2021 INLET 460HR 86 98 3.96 23 2

TEA UTE

-0.16 UTE UTE 2022 INLET 460HR 86 99 1.55 31 2

TEA UTE

-0.18 UTE UTE 2021 INLET 460HR 86 104 2.74 20 2

TEA UTE

-0.21 UTE UTE 2022 INLET 460HR 86 105

1. 25 41 2

TEA UTE

-0.28 UTE UTE 2021 INLET 460HR 86 106 2.59 22 2

TEA UTE

-0.24 UTE UTE 2022 INLET 460HR 86 107 1.25 36 2

TEA UTE

-0.20 UTE UTE 2021 INLET 460HR 86 109 3.30 30 2

TEA UTE

-0.24 UTE UTE 2021 INLET 460HR 86 110 3.01 32 2

TEA UTE

-0.18 UTE UTE 2022 INLET 460HR 86 112

1. 43 21 2

TEA UTE

-0.23 UTE UTE 2022 INLET 460HR 86 113 7.62 31 2

TEA UTE

-0.19 UTE UTE 2071 INLET 460HR 86 114 2.13 18 2

TEA UTE

-0.19 UTE UTE 2072 INLET 460HR 86 116 6.04 26 2

TEA UTE

-0.19 UTE UTE 2072 INLET 460HR 86 117 5.31 30 2

TEA UTE

-0.21 UTE UTE 2071 INLET 460HR 86 120 0.07 83 2

VOL 014

+1.01 014 014 4047 OUTLET 460SI 86 122 3.36 30 2

TEA UTE

-0.20 UTE UTE 2071 INLET 460HR 86 123 2.55 26 2

TEA UTE

-0.17 UTE UTE 2072 INLET 460HR 86 124 2.25 25 2

TEA UTE

-0.18 UTE UTE 2071 INLET 460HR 86 129 6.34 27 2

TEA UTE

-0.19 UTE UTE 2071 INLET 460HR 9.50 176 1 DNT 009

+0.18 009 009 4049 OUTLET 460S1 0.06 97 2

VOL 014

+1.38 014 014 4049 OUTLET 460S1 87 2

4.40 17 P 1 DRS UTE

-0.71 UTE UTE SLV 1004 INLET 400PS 87 3

0.22 56 2

VOL 012

+0.86 012 012 4038 OUTLET 460S1 87 5

5.65 177 1 DNT LTE

+11.29 LTE LTE 4092 OUTLET 460SI 4.18 176 1 DNT LTE

+10.76 LTE LTE 4092 OUTLET 460S1 0.29 82 2

VOL

'012

+1.39 012 012 4092 OUTLET 460SI 5.27 175 1 DNT UTE

-12.42 UTE UTE 4092 OUTLET 460S1 87 8

2.02 16 2

TEA UTE

-0.12 UTE UTE 2121 INLET 460HR 87 9

0.19 75 2

VOL 014

+1.10 014 014 4092 OUTLET 460SI 87 10 0.26 86 P 3 TWD 7 008

+0.64 008 008 WAR 4092 OUTLET 460SI 0.20 84 2

VOL 014

+0.77 014 014 4092 OUTLET 460SI 1.93 23 2

TEA UTE

-0.10 UTE UTE 2121 INLET 460HR 87 16 0.43 75 P 3 TWD 11 008

+0.66 008 008 WAR 4092 OUTLET 460SI 0.26 60 2

VOL 014

+0.72 014 014 4092 OUTLET 460SI 87 17 6.80 177 1 DNT UTE

-11.23 UTE UTE 4092 OUTLET 460SI 6.68 167 1 DNT LTE

+10.90 LTE LTE 4092 OUTLET 460SI

1. 37 27 2

TEA UTE

-0.21 UTE UTE 2120 INLET 460HR 87 18 0.61 188 2 DNT LTE

+10.79 LTE LTE 4092 OUTLET 460SI 2.07 182 1 DNT UTE

-6.74 UTE UTE 4092 OUTLET 460SI 6.05 183 1 DNT UTE

-11.56 UTE UTE 4092 OUTLET 460SI

Framatome ANP Inc.

05/02/02 13:29:54 Customer Name: Oconee Unit 1 Component: S/G B Page 94 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

87 26 2.74 21 2

TEA UTE

-0.13 UTE UTE 2121 INLET 460HR 87 27 3.02 29 2

TEA UTE

-0.16 UTE UTE 2120 INLET 460HR 87 28 3.59 21 1

TEA UTE

-0.06 UTE UTE 2121 INLET 460HR 87 29 2.85 24 2

TEA UTE

-0.15 UTE UTE 2120 INLET 460HR 87 30 3.57 20 2

TEA UTE

-0.12 UTE UTE 2121 INLET 460HR 87 31 5.92 25 2

TEA UTE

-0.19 UTE UTE 2120 INLET 460HR 87 35

1. 78 24 2

TEA UTE

-0.17 UTE UTE 2120 INLET 460HR 87 36 2.09 20 2

TEA UTE

-0.12 UTE UTE 2121 INLET 460HR 87 37 2.70 30 2

TEA UTE

-0.24 UTE UTE 2120 INLET 460HR 87 39 2.62 20 2

TEA UTE

-0.19 UTE UTE 2120 INLET 460HR 87 40 1.50 15 2

TEA UTE

-0.07 UTE UTE 2121 INLET 460HR 87 42 4.67 25 2

TEA UTE

-0.12 UTE UTE 2121 INLET 460HR 87 46

1. 89 16 2

TEA UTE

-0.10 UTE UTE 2121 INLET 460HR 87 48 2.47 24 2

TEA UTE

-0.17 UTE UTE 2121 INLET 460HR 87 54 3.33 21 2

TEA UTE

-0.14 UTE UTE 2121 INLET 460HR 87 59 3.32 21 2

TEA UTE

-0.16 UTE UTE 2008 INLET 460HR 87 62 4.05 24 2

TEA UTE

-0.21 UTE UTE 2007 INLET 460HR 87 64 2.90 23 2

TEA UTE

-0.20 UTE UTE 2007 INLET 460HR 2.60 182 1 DNT 013

-9.40 013 013 4003 INLET 460S1 87 72 3.21 21 2

TEA UTE

-0.24 UTE UTE 2013 INLET 460HR 1.12 178 1 DNT UTS

+1.96 UTS UTS 4003 INLET 460S1 87 73 4.88 25 2

TEA UTE

-0.24 UTE UTE 2001 INLET 460HR 0.89 14 2

VOL UTE

-1.25 UTE UTE 2001 INLET 460HR 87 74 1.89 22 2

TEA UTE

-0.33 UTE UTE 2001 INLET 460HR 87 75

1. 06 24 2

TEA UTE

-0.17 UTE UTE 2021 INLET 460HR 87 76 2.98 19 2

TEA UTE

-0.20 UTE UTE 2022 INLET 460HR 87 78 4.06 179 1 DNT LTE

+9.25 LTE LTE 4033 OUTLET 460S1 5.17 176 1 ONT LTE

+11.48 LTE LTE 4033 OUTLET 460S1 87 83 0.58 55 2

TEA UTE

-0.19 UTE UTE 2021 INLET 460HR 87 84 3.07 20 2

TEA UTE

-0.17 UTE UTE 2022 INLET 460HR 87 91 2.74 30 2

TEA UTE

-0.17 UTE UTE 2021 INLET 460HR 87 92 3.16 28 P 1 SCI UTE

-0.12 UTE UTS CL 2022 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.12 TO+214.2 UTE UTS 2022 INLET 460HR

1. 14 26 P 3 TWO 20 UTE

-0.12 TO+223.3 UTE UTS 2022 INLET 460HR

1. 90 32 P 3 TWD 34 UTE

-0.12 TO+232.4 UTE UTS 2022 INLET 460HR 4.06 28 P 3 TWD 78 UTE

-0.12 TO+241.5 UTE UTS 2022 INLET 460HR 4.20 31 P 3 TWO 81 UTE

-0.12 TO+250.6 UTE UTS 2022 INLET 460HR 2.87 37 P 3 TWO 54 UTE

-0.12 TO+259.7 UTE UTS 2022 INLET 460HR 3.05 31 P 3 TWO 57 UTE

-0.12 TO+268.9 UTE UTS 2022 INLET 460HR 3.18 30 P 3 TWO 60 UTE

-0.12 TO+278.0 UTE UTS 2022 INLET 460HR 2.17 37 P 3 TWO 40 UTE

-0.12 TO+287.1 UTE UTS 2022 INLET 460HR 1.50 44 P 3 TWO 26 UTE

-0.12 TO+296.2 UTE UTS 2022 INLET 460HR 1.20 49 P 3 TWO 21 UTE

-0.12 TO+305.3 UTE UTS 2022 INLET 460HR

1. 37 38 P 3 TWO 24 UTE

-0.12 TO+314.4 UTE UTS 2022 INLET 460HR 0.94 42 P 3 TWO 16 UTE

-0.12 TO+323.5 UTE UTS 2022 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.12 TO+332.7 UTE UTS 2022 INLET 460HR 87 94 2.21 22 2

TEA UTE

-0.15 UTE UTE 2022 INLET 460HR 87 97

1. 92 32 2

TEA UTE

-0.17 UTE UTE 2021 INLET 460HR 87 108 2.33 19 2

TEA UTE

-0.20 UTE UTE 2022 INLET 460HR 87 109 1.20 20 2

TEA UTE

-0.22 UTE UTE 2021 INLET 460HR 87 110 0.30 41 P 3 TWO 8 014

+0.66 014 014 WAR 4039 OUTLET 460SI 87 111 0.97 31 2

TEA UTE

-0.23 UTE UTE 2021 INLET 460HR 87 113 6.36 26 2

TEA UTE

-0.13 UTE UTE 2071 INLET 460HR 87 115 3.03 28 2

TEA UTE

-0.19 UTE UTE 2071 INLET 460HR 87 116 0.20 82 9

PLP 014

+1.09 014 014 4047 OUTLET 460S1 87 118 5.07 26 2

TEA UTE

-0.16 UTE UTE 2072 INLET 460HR 87 120 2.89 34 2

TEA UTE

-0.14 UTE UTE 2071 INLET 460HR 87 121 3.72 20 2

TEA UTE

-0.16 UTE UTE 2072 INLET 460HR 87 122 4.81 30 2

TEA UTE

-0.19 UTE UTE 2071 INLET 460HR 8.07 176 1 ONT LTE

+10.29 LTE LTE 4047 OUTLET 460SI 10.25 179 1 ONT UTE

-12.01 UTE UTE 4047 OUTLET 460SI 87 123 6.69 162 1 ONT LTE

+9.93 LTE LTE 4049 OUTLET 460SI 0.47 61 P 3 TWO 12 010

-0.19 010 010 WAR 4049 OUTLET 460SI 9.15 174 1 ONT UTE

-11. 93 UTE UTE 4049 OUTLET 460S1 87 124 4.20 35 2

TEA UTE

-0.20 UTE UTE 2071 INLET 460HR 87 125 3.24 22 2

TEA UTE

-0.13 UTE UTE 2072 INLET 460HR 8.00 178 1 DNT LTE

+10.38 LTE LTE 4049 OUTLET 460SI 0.22 74 P 3 TWO 9 007

-0.11 007 007 WAR 4049 OUTLET 460SI 0.34 86 P 3 TWO 13 008

+0.56 008 008 WAR 4049 OUTLET 460SI 7.23 177 1 ONT UTE

-12.07 UTE UTE 4049 OUTLET 460SI 7.90 176 1 ONT UTE

-11.57 UTE UTE 4049 OUTLET 460SI 87 128 3.35 26 2

TEA UTE

-0.13 UTE UTE 2072 INLET 460HR 9.45 176 1 ONT 009

-0.28 009 009 4049 OUTLET 460SI 0.11 83 2

VOL 014

+1.13 014 014 4049 OUTLET 460S1 88 2

4.05 20 P 1 DRS UTE

-0.82 UTE UTE SLV 1004 INLET 400PS

Framatome ANP Inc.

05/02/02 13:29:55 Customer Name: Oconee Unit 1 Component: S/G B Page 95 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMI ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

0.21 143 P 3 TWO 3 014

+0.74 014 014 WAR 4038 OUTLET 460S1 88 4

4.32 22 P 1 ORS UTE

-0.75 UTE UTE SLV 1004 INLET 400PS 88 10 0.53 51 P 3 TWO 13 009

+0.65 009 009 WAR 4092 OUTLET 460SI 0.53 101 P 3 TWO 13 010

+0.72 010 010 WAR 4092 OUTLET 460S1 88 15 1.18 19 2

TEA UTE

-0.l3 UTE UTE 2118 INLET 460HR 88 22

1. 60 24 2

TEA UTE

-0.20 UTE UTE 2119 INLET 460HR 88 29 2.83 36 2

TEA UTE

-0.24 UTE UTE 2120 INLET 460HR 88 48 1.14 18 2

TWO 50 UTE

-1.14 UTE UTE 2121 INLET 460HR 1.14 18 2

SAl UTE

-1.14 UTE UTE TR 2121 INLET 460HR 88 51 0.28 16 2

VOL UTE

-3.61 UTE UTS 2120 INLET 460HR 88 60 1.81 28 2

TEA UTE

-0.l7 UTE UTE 2001 INLET 460HR 88 67 2.02 22 2

TEA UTE

-0.29 UTE UTE 2001 INLET 460HR 88 69 4.35 180 1 ONT 014

-l7.66 014 014 4003 INLET 460S1 88 72 6.73 184 1 ONT 009

-5.93 009 009 4003 INLET 460SI 88 73 4.44 13 1

ONT 001

-22.92 001 001 4003 INLET 460S1 3.63 189 1 ONT LTS

+22.37 001 LTS 4004 INLET 460S1 88 78 2.28 16 P 1 SCI UTE

-0.15 UTE UTS CL 2022 INLET 460HR 0.75 23 P 3 TWO l7 UTE

-0.15 TO+O.O UTE UTS 2022 INLET 460HR

1. 43 17 P 3 TWO 35 UTE

-0.15 TO+9.1 UTE UTS 2022 INLET 460HR 2.27 20 P 3 TWO 59 UTE

-0.15 TO+18.2 UTE UTS 2022 INLET 460HR 2.14 21 P 3 TWO 55 UTE

-0.15 TO+27.3 UTE UTS 2022 INLET 460HR

1. 69 23 P 3 TWO 42 UTE

-0.15 TO+36.5 UTE UTS 2022 INLET 460HR 1.14 15 P 3 TWO 27 UTE

-0.15 TO+45.6 UTE UTS 2022 INLET 460HR 0.31 26 P 3 TWO 6 UTE

-0.15 TO+54.7 UTE UTS 2022 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.15 TO+63.8 UTE UTS 2022 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.15 TO+341.8 UTE UTS 2022 INLET 460HR 0.30 32 P 3 TWO 5 UTE

-0.15 TO+350.9 UTE UTS 2022 INLET 460HR 88 85 5.61 173 1 ONT LTE

+5.39 LTE LTE 4033 OUTLET 460S1 88 90 0.44 20 P 4 TWO 91 UTE

-0.86 UTE UTE 2022 INLET 460HR 0.44 20 2

SVI UTE

-0.86 UTE UTE CS 2022 INLET 460HR 88 94 3.73 23 P 1 SCI UTE

-0.07 UTE UTE CL 2022 INLET 460HR

1. 45 11 P 3 TWO 14 UTE

-0.07 TO+9.1 UTE UTE 2022 INLET 460HR

1. 69 28 P 3 TWO l7 UTE

-0.07 TO+18.2 UTE UTE 2022 INLET 460HR 4.01 26 P 3 TWO 70 UTE

-0.07 TO+27.3 UTE UTE 2022 INLET 460HR 3.06 28 P 3 TWO 42 UTE

-0.07 TO+36.5 UTE UTE 2022 INLET 460HR 3.16 41 P 3 TWO 45 UTE

-0.07 TO+45.6 UTE UTE 2022 INLET 460HR 3.91 39 P 3 TWO 67 UTE

-0.07 TO+54.7 UTE UTE 2022 INLET 460HR 3.75 37 P 3 TWO 61 UTE

-0.07 TO+63.8 UTE UTE 2022 INLET 460HR 2.73 34 P 3 TWO 35 UTE

-0.07 TO+72.9 UTE UTE 2022 INLET 460HR 1.26 17 P 3 TWO 11 UTE

-0.07 TO+82.0 UTE UTE 2022 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.07 TO+91.1 UTE UTE 2022 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.07 TO+O.O UTE UTE 2022 INLET 460HR 88 96 0.73 13 2

SAl UTE

-3.84 UTE UTS TR 2022 INLET 460HR 0.73 13 2

TWO 31 UTE

-3.84 UTE UTS 2022 INLET 460HR 88 116 0.62 35 P 3 TWO 15 009

+0.29 009 009 WAR 4047 OUTLET 460S1 0.36 155 P 3 TWO 7 010

+0.07 010 010 WAR 4047 OUTLET 460S1 88 ll7 0.27 161 P 3 TWO 5 008

+0.74 008 008 WAR 4047 OUTLET 460S1 88 ll8 0.46 115 P 3 TWO 9 009

-0.77 009 009 WAR 4047 OUTLET 460S1 0.42 163 P 3 TWO 8 010

+0.13 010 010 WAR 4047 OUTLET 460S1 88 120 0.93 32 2

SAl UTE

-3.58 UTE UTS 2071 INLET 460HR 0.93 32 2

TWO 84 UTE

-3.58 UTE UTS 2071 INLET 460HR 0.42 12 P 3 TWO 8 009

+0.19 009 009 WAR 4047 OUTLET 460S1 0.49 127 P 3 TWO 9 010

+0.20 010 010 WAR 4047 OUTLET 460S1 88 121 2.98 23 2

TEA UTE

-0.16 UTE UTE 2072 INLET 460HR 8.33 171 1 ONT LTE

+9.26 LTE LTE 4047 OUTLET 460S1 7.70 l76 1 ONT UTE

-11.68 UTE UTE 4047 OUTLET 460S1 88 123 6.50 l72 1 ONT LTE

+8.45 LTE LTE 4049 OUTLET 460S1 8.01 178 1 ONT UTE

-11. 50 UTE UTE 4049 OUTLET 460S1 88 129 2.39 24 2

TEA UTE

-0.16 UTE UTE 2072 INLET 460HR 89 2

6.83 18 P 1 ORS UTE

-0.76 UTE UTE SLY 1004 INLET 400PS 89 10 0.47 106 P 3 TWO 8 010

-0.77 010 010 WAR 4092 OUTLET 460S1 89 13 0.43 90 P 3 TWO 11 008

+0.70 008 008 WAR 4092 OUTLET 460S1 2.79 22 2

TEA UTE

-0.28 UTE UTE 2119 INLET 460HR 89 16

1. 46 27 2

MAl UTE

-3.56 UTE UTS 2118 INLET 460HR

1. 46 27 2

TWO 76 UTE

-3.56 UTE UTS 2118 INLET 460HR 89 20 2.29 26 2

TEA UTE

-0.14 UTE UTE 2118 INLET 460HR 89 21

1. 56 29 2

MAl UTE

-3.65 UTE UTS 2119 INLET 460HR

1. 56 29 2

TWO 93 UTE

-3.65 UTE UTS 2119 INLET 460HR 89 25 3.08 l7 2

TEA UTE

-0.16 UTE UTE 2119 INLET 460HR 89 29 2.89 24 2

TEA UTE

-0.18 UTE UTE 2119 INLET 460HR 89 33 0.40 27 P 1 SCI UTE

-3.66 UTE UTS 2119 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.66 TO+144.0 UTE UTS 2119 INLET 460HR 0.31 10 P 3 TWO 23 UTE

-3.66 TO+153.0 UTE UTS 2119 INLET 460HR 0.40 12 P 3 TWD 30 UTE

-3.66 TO+l62.0 UTE UTS 2119 INLET 460HR 0.31 12 P 3 TWO 24 UTE

-3.66 TO+l71. 0 UTE UTS 2119 INLET 460HR

Framatome ANP Inc.

05/02/02 13:29:56 Customer Name: Oconee Unit 1 Component: S/G B Page 96 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
::;;=:::;==

0.00 0

P 3 TWD 0 UTE

-3.66 TO+180.0 UTE UTS 2119 INLET 460HR 89 54 5.73 24 2

TEA UTE

-0.12 UTE UTE 2119 INLET 460HR 89 55 1.39 23 2

TEA UTE

-0.24 UTE UTE 2118 INLET 460HR 89 56 8.36 29 2

TEA UTE

-0.21 UTE UTE 2122 INLET 460HR 89 74 1.02 26 2

TEA UTE

-0.20 UTE UTE 2021 INLET 460HR 89 75 2.85 20 2

TEA UTE

-0.22 UTE UTE 2022 INLET 460HR 89 79

1. 42 17 2

TEA UTE

-0.12 UTE UTE 2022 INLET 460HR 89 80 1.53 25 2

TEA UTE

-0.18 UTE UTE 2021 INLET 460HR 89 81 4.50 19 2

TEA UTE

-0.16 UTE UTE 2022 INLET 460HR 89 83 0.95 20 2

TEA UTE

-0.24 UTE UTE 2021 INLET 460HR 89 86 1.28 21 2

SAl UTE

-4.01 UTE UTS TR 2021 INLET 460HR 1.28 21 2

TWD 53 UTE

-4.01 UTE UTS 2021 INLET 460HR 89 95 2.13 18 2

TEA UTE

-0.12 UTE UTE 2022 INLET 460HR 0.72 15 2

SAl UTE

-1.10 UTE UTE TR 2022 INLET 460HR 0.72 15 2

TWD 39 UTE

-1.10 UTE UTE 2022 INLET 460HR 89 107

1. 24 2

2 TEA UTE

-0.14 UTE UTE 2022 INLET 460HR 89 112 9.23 179 1 DNT LTE

+5.62 LTE LTE 4039 OUTLET 46081 89 117 0.49 90 P 3 TWD 9 009

-0.11 009 009 WAR 4047 OUTLET 460SI 89 119 0.67 153 P 3 TWD 12 010

-0.16 010 010 WAR 4047 OUTLET 460SI 89 120 0.46 84 2

VOL 009

+0.82 009 009 4047 OUTLET 460SI 89 122 7.02 178 1 DNT LTE

+9.88 LTE LTE 4047 OUTLET 460SI 9.44 183 1 DNT UTE

-11. 77 UTE UTE 4047 OUTLET 460S1 89 124 7.24 177 1 DNT LTE

+8.49 LTE LTE 4049 OUTLET 460S1 7.40 177 1 DNT LTE

+10.69 LTE LTE 4049 OUTLET 46081 5.16 175 1 DNT UTE

-11. 82 UTE UTE 4049 OUTLET 460SI 89 126 8.29 177 1 DNT LTE

+8.70 LTE LTE 4049 OUTLET 460SI 0.09 80 2

VOL 014

+1. 43 014 014 4049 OUTLET 460S1 6.43 179 1 DNT UTE

-11.52 UTE UTE 4049 OUTLET 460S1 89 128 0.39 75 2

VOL 008

+1.20 008 008 4049 OUTLET 460S1 0.13 77 2

VOL 008

+1. 63 008 008 4049 OUTLET 460SI 0.37 104 2 VOL 011

+1.10 011 011 4049 OUTLET 46081 0.41 80 2

VOL 013

+1.54 013 013 4049 OUTLET 460S1 89 129 8.03 171 1 DNT LTE

+12.05 LTE LTE 4047 OUTLET 460S1 0.66 81 2

VOL 011

+0.87 011 011 4047 OUTLET 460S1 0.10 78 10 PLP 011

+1. 01 011 011 4047 OUTLET 460S1 10.14 180 1 DNT UTE

-12.48 UTE UTE 4047 OUTLET 460S1 90 2

0.12 81 2

VOL 014

+1. 35 014 014 4092 OUTLET

.460SI 0.18 74 2

VOL 014

+1. 71 014 014 4092 OUTLET 460SI 90 6

1. 00 121 P 3 TWD 21 010

-0.77 010 010 WAR 4092 OUTLET 460S1 0.10 86 2

VOL 014

+1.17 014 014 4092 OUTLET 460SI 90 7

0.29 68 2

VOL 011

+0.78 011 011 4092 OUTLET 460SI 90 8

0.68 98 P 3 TWD 14 010

+0.76 010 010 WAR 4092 OUTLET 460SI 0.17 73 2

VOL 011

+1. 23 011 011 4092 OUTLET 460S1 0.19 70 2

VOL 014

+1. 04 014 014 4092 OUTLET 460S1 90 11 0.48 76 P 3 TWO 13 009

+0.61 009 009 WAR 4095 OUTLET 460S1 90 18 0.69 24 P 4 SVI UTE

-1.15 UTE UTE TR 2118 INLET 460HR 0.69 24 P 4 TWD 96 UTE

-1.15 UTE UTE 2118 INLET 460HR 90 38 0.22 89 2

VOL 011

+0.95 011 011 4069 INLET 460S1 0.40 95 2

VOL 011

+0.76 011 011 4069 INLET 460SI 90 40 0.14 80 2

VOL 011

+1.14 011 011 4069 INLET 460SI 0.45 134 P 3 TWO 10 007

-0.37 007 007 WAR 4069 INLET 460S1 90 45 3.01 26 2

TEA UTE

-0.23 UTE UTE 2118 INLET 460HR 90 48 0.22 76 2

VOL 011

+0.71 011 011 4069 INLET 460SI 0.16 74 2

VOL 011

+1. 06 011 011 4069 INLET 460S1 90 51 2.47 19 2

TEA UTE

-0.23 UTE UTE 2118 INLET 460HR 90 57 2.15 110 1 VOL 002

+15.18 TO+15.93 002 002 4095 OUTLET 460S1 90 63 2.78 173 1 ONT LTE

+6.46 LTE LTE 4003 INLET 460SI 3.44 173 1 DNT LTE

+5.87 LTE LTE 4003 INLET 460SI 90 64 1.66 187 1 DNT LTE

+9.43 LTE LTE 4003 INLET 460SI 0.93 181 1 DNT LTE

+8.80 LTE LTE 4003 INLET 460SI 90 66

1. 52 31 2

TEA UTE

-0.20 UTE UTE 2002 INLET 460HR 90 68

1. 81 22 2

TEA UTE

-0.20 UTE UTE 2001 INLET 460HR 90 75 2.27 16 2

TEA UTE

-0.19 UTE UTE 2022 INLET 460HR 90 82 1.16 21 2

TEA UTE

-0.18 UTE UTE 2021 INLET 460HR 90 83 2.50 24 2

TEA UTE

-0.12 UTE UTE 2022 INLET 460HR 90 84 0.68 29 2

TEA UTE

-0.20 UTE UTE 2021 INLET 460HR 90 93 1.40 178 1 DNT LTS

+13.65 LTS LTS 4033 OUTLET 460SI 90 95 1.31 13 2

TEA UTE

-0.15 UTE UTE 2026 INLET 460HR 90 96 2.48 21 2

TEA UTE

-0.17 UTE UTE 2025 INLET 460HR 90 101 4.45 173 1 DNT 008

-5.43 008 008 4033 OUTLET 460SI 90 103 3.49 24 2

TEA UTE

-0.18 UTE UTE 2026 INLET 460HR 90 104 1.39 22 2

TEA UTE

-0.26 UTE UTE 2025 INLET 460HR 90 112 1.32 18 2

TEA UTE

-0.13 UTE UTE 2026 INLET 460HR 90 114 0.15 53 2

VOL 014

+0.99 014 014 4044 OUTLET 460SI 0.22 25 2

VOL 014

+0.85 014 014 4044 OUTLET 460SI

Framatome ANP Inc.

05/02/02 13:29:57 Customer Name: Oconee Unit 1 Component: 8/G B Page 97 of 155 ATTACHMENT #4 -

LI8T OF IMPERFECTION8 -

MRPC/PLU8 POINT QUERY: QueryMl ROW TUBE VOLT8 DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

1.07 25 2

8AI UTE

-3.67 UTE UT8 2071 INLET 460HR 1.07 25 2

TWD 68 UTE

-3.67 UTE UT8 2071 INLET 460HR 90 117 0.82 109 P 3 TWD 16 008

+0.63 008 008 WAR 4087 OUTLET 46081 0.26 69 P 3 TWD 6 008

-0.67 008 008 WAR 4087 OUTLET 46081 90 120 0.32 0

P 3 TWD 9 010

+0.69 010 010 WAR 4087 OUTLET 46081 90 121 3.77 24 2

TEA UTE

-0.19 UTE UTE 2072 INLET 460HR 90 122 0.26 84 2

VOL 011

+1.06 011 011 4047 OUTLET 46081 90 123 9.21 172 1 DNT LTE

+10.95 LTE LTE 4047 OUTLET 46081 8.51 176 1 DNT LTE

+11. 55 LTE LTE 4047 OUTLET 46081 8.11 177 1 DNT UTE

-11.38 UTE UTE 4047 OUTLET 46081 91 3

4.20 176 1 DNT LTE

+11.52 LTE LTE 4095 OUTLET 46081 2.83 173 1 DNT UTE

-12.21 UTE UTE 4095 OUTLET 46081 2.34 29 2

TEA UTE

-0.14 UTE UTE 2118 INLET 460HR 91 4

31. 34 12 1

MCI LTE

+2.11 LTE LTE 708 OUTLET 380EX 91 5

2.75 341 1 DNT LTE

+10.89 LTE LTE 4095 OUTLET 46081 4.50 175 1 DNT LTE

+11.70 LTE LTE 4095 OUTLET 46081 4.80 173 1 DNT 010

-0.49 010 010 4095 OUTLET 46081 6.19 352 1 DNT UTE

-11. 00 UTE UTE 4095 OUTLET 46081 91 8

0.08 59 2

VOL 014

+0.89 014 014 4095 OUTLET 46081 91 16 0.19 104 P 3 TWD 6 008

+0.78 008 008 WAR 4095 OUTLET 46081 91 17 0.59 66 p 3 TWD 12 008

+0.54 008 008 WAR 4113 OUTLET 52081 91 24 2.06 28 2

8AI UTE

-3.66 UTE UT8 2118 INLET 460HR 2.06 28 2

TWD 80 UTE

-3.66 UTE UT8 2118 INLET 460HR 91 44 0.37 25 2

8AI UTE

-3.79 UTE UT8 2118 INLET 460HR 0.37 25 2

TWD 70 UTE

-3.79 UTE UT8 2118 INLET 460HR 91 46 0.96 45 2

TEA UTE

-0.16 UTE UTE 2118 INLET 460HR 91 53 0.12 37 2

8AI 012

-15.17 012 012 4069 INLET 46081 0.09 48 2

TWD 88 012

-15.17 012 012 4069 INLET 46081 91 69 2.26 25 2

TEA UTE

-0.12 UTE UTE 2002 INLET 460HR 91 78

1. 90 21 2

TEA UTE

-0.16 UTE UTE 2025 INLET 460HR 91 82

1. 64 20 2

TEA UTE

-0.22 UTE UTE 2025 INLET 460HR 91 86 0.08 102 2 VOL 015

+2.79 015 015 4033 OUTLET 46081 91 107 0.91 26 2

TEA UTE

-0.22 UTE UTE 2025 INLET 460HR 91 110 0.18 45 2

VOL 010

+1.10 010 010 4039 OUTLET 46081 0.13 41 2

VOL 010

+1. 29 010 010 4039 OUTLET 46081 91 111 4.08 36 2

TEA UTE

-0.15 UTE UTE 2071 INLET 460HR 91 113 0.22 0

P 3 TWD 6 008

-0.68 008 008 WAR 4087 OUTLET 46081 91 114 0.15 84 2

VOL 014

+1. 23 014 014 4047 OUTLET 46081 91 115 0.12 95 2

VOL 014

+0.83 014 014 4087 OUTLET 46081 91 119

1. 64 19 2

TEA UTE

-0.16 UTE UTE 2071 INLET 460HR 91 120

1. 05 21 2

TEA UTE

-0.20 UTE UTE 2072 INLET 460HR 7.08 170 1 DNT LTE

+11. 30 LTE LTE 4047 OUTLET 46081 7.40 178 1 DNT UTE

-11.64 UTE UTE 4047 OUTLET 46081 8.10 177 1 DNT UTE

-12.25 UTE UTE 4047 OUTLET 46081 91 121 6.19 174 1 DNT UTE

-10.81 UTE UTE 4109 OUTLET 46081 6.67 2

1 DNT LTE

+10.94 LTE LTE 4087 OUTLET 46081 7.77 179 1 DNT LTE

+11.08 LTE LTE 4091 OUTLET 46081 2.43 21 2

TEA UTE

-0.21 UTE UTE 2071 INLET 460HR 91 124 0.11 100 2 VOL 014

+0.90 014 014 4047 OUTLET 46081 92 2

2.37 22 2

TEA UTE

-0.22 UTE UTE 2118 INLET 460HR 92 5

1. 77 20 2

TEA UTE

-0.12 UTE UTE 2119 INLET 460HR 92 12 5.16 348 1 DNT 012

+6.96 012 012 4095 OUTLET 46081 92 15 0.52 74 P 3 TWD 9 008

+0.71 008 008 WAR 4095 OUTLET 46081 0.33 112 P 3 TWD 10 009

+0.47 009 009 WAR 4095 OUTLET 46081 92 19

1. 01 26 2

MAl UTE

-3.61 UTE UT8 2119 INLET 460HR 1.25 27 2

TWD 84 UTE

-3.61 UTE UT8 2119 INLET 460HR 92 28 0.43 113 P 3 TWD 12 007

+0.50 007 007 WAR 4095 OUTLET 46081 92 31 0.54 18 P 1 8CI UTE

-3.61 UTE UT8 2119 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-3.61 TO+146.7 UTE UTS 2119 INLET 460HR 0.27 29 P 3 TWD 33 UTE

-3.61 TO+155.6 UTE UT8 2119 INLET 460HR 0.40 18 P 3 TWD 50 UTE

-3.61 TO+164.4 UTE UTS 2119 INLET 460HR 0.24 13 P 3 TWD 29 UTE

-3.61 TO+173.3 UTE UT8 2119 INLET 460HR 0.14 24 P 3 TWD 17 UTE

-3.61 TO+182.2 UTE UT8 2119 INLET 460HR 0.09 22 P 3 TWD 11 UTE

-3.61 TO+191. 1 UTE UT8 2119 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-3.61 TO+200.0 UTE UTS 2119 INLET 460HR 92 33 6.74 21 2

TEA UTE

-0.22 UTE UTE 2119 INLET 460HR 92 48 3.06 176 1 DNT LTS

-0.02 LT8 LTS 4069 INLET 46081 92 49 5.46 184 1 DNT 010

-12.01 010 010 4069 INLET 4608I

1. 62 28 2

TEA UTE

-0.14 UTE UTE 2119 INLET 460HR 92 58 0.28 127 P 3 TWD 7 007

-0.48 007 007 WAR 4095 OUTLET 46081 92 69 2.46 181 1 DNT LTE

+3.30 LTE LTE 4003 INLET 46081 92 73 2.49 181 1 DNT 008

-8.18 008 008 4003 INLET 46081 92 87 0.16 109 2 VOL 010

+1.14 010 010 4033 OUTLET 46081 92 93 3.50 174 1 DNT UTE

-11.00 UTE UTE 4033 OUTLET 46081 92 108 2.31 23 2

TEA UTE

-0.19 UTE UTE 2025 INLET 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 92 114 92 123 92 124 92 125 92 126 92. 127 92 128 92 129 93 3

93 11 93 16 93 27 93 30 93 33 93 45 93 57 93 61 93 69 93 73 93 75 93 78 93 83 93 92 93 94 93 109 93 111 93 114 93 118 7.45 6.43 3.16 9.02 9.25

1. 60 7.97 0.26 7.99 3.38
1. 78
1. 91 8.30
11. 58 0.16 0.20 0.12 2.63 0.99 3.71 0.35 0.23 0.17 0.17 0.33 0.33 1.24 0.53 0.00 0.17 0.53 0.57 0.53 0.60 0.41 0.28 0.13 0.00 3.41 0.40 0.00 0.18 0.40 0.19 0.08 2.36 2.40 2.52 1.82 2.38 0.18 0.07
1. 42 0.16 1.15 5.10 0.00 0.77 2.85 5.85 3.59 0.77 0.00 1.14 5.61
1. 49 8.10 8.45
11. 03 0.92 8.50 2.15 0.56 0.37 10.07 ONT ONT TEA ONT ONT TEA ONT 3 TWO 5 ONT TEA TEA TEA ONT ONT VOL VOL VOL TEA 169 1 177 1 28 2

176 1 179 1 20 2

174 1 161 P 175 1 26 2

25 2

21 2

173 1 179 1 61 2

98 2

72 2

23 2

75 P 3 TWO 15 2

TEA 22 76 o

83 83 74 74 109 16 o

41 18 21 25 23 21 21 27 o

19 14 o

14 17 11 o

173 356 350 188 176 84 74 13 137 29 24 o

2 22 27 29 18 o

17 23 23 177 180 169 87 174 21 89 87 172 2

VOL P 3 TWO 4 2

SAl 2

TWO 0 2

SAl 2

TWO 32 P 3 TWO 14 P 1 SCI P 3 TWO 0 P 3 TWO 20 P 3 TWO 60 P 3 TWO 64 P 3 TWO 60 P 3 TWO 68 P 3 TWO 47 P 3 TWO 31 P 3 TWO 15 P 3 TWO 0 2

TEA P 1 SCI P 3 TWO 0 P 3 TWO 20 P 3 TWO 46 P 3 TWO 22 P 3 TWO 0 1

ONT 1

ONT 1

ONT 1

ONT 1

ONT 2

SAl 2

TWO 82 2

TEA P 3 TWO 4 2

TEA P 1 SCI P 3 TWO 0 P 3 TWO 12 P 3 TWO 42 P 3 TWO 78 P 3 TWO 52 P 3 TWO 12 P 3 TWO 0 2

TEA 2

TEA 2

TEA 1

ONT 1

ONT 1

ONT P 3 TWO 14 1

ONT 2

TEA P 3 TWO 9 P 3 TWO 6 1

ONT LTE UTE UTE LTE UTE UTE LTE 009 UTE UTE UTE UTE 007 009 013 011 013 UTE 011 UTE 013 009 015 015 015 015 009 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTS UTE UTE LTE LTE 012 012 UTE 006 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE UTE LTE 008 UTE UTE 008 008 LTE

+11.03

-11. 30

-0.23

+10.91

-11. 91

-0.20

+11. 30

-0.46

-12.12

-0.19

-0.25

-0.17

-3.85

-0.11

+1.28

+1. 41

+1.26

-0.17

+0.22

-0.22

+1.14

-0.65

-5.94

-5.94

-4.04

-4.04

-0.70

-3.57

-3.57

-3.57

-3.57

-3.57

-3.57

-3.57

-3.57

-3.57

-3.57

-3.57

-0.20

-1.19

-1.19

-1.19

-1.19

-1. 19

-1.19

-0.03

-6.46

-6.73

+8.63

+9.64

+9.71

+9.71

-0.16

-0.63

-0.16

-0.37

-0.37

-0.37

-0.37

-0.37

-0.37

-0.37

-0.37

-0.14

-0.12

-0.15

+11.11

-11. 20

+11. 28

-0.70

-11. 65

-0.21

+0.59

-0.58

+10.64 TO+44.4 TO+53.3 TO+62.2 TO+71.1 TO+80.0 TO+88.9 TO+97.8 TO+106.7 TO+115.6 TO+124.4 TO+346.7 TO+337.8 TO+328.9 TO+320.0 TO+311.1 TO+150.4 TO+159.5 T0+168.6 TO+177.7 TO+186.8 TO+195.9 TO+205.1 05/02/02 13:29:58 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG LTE LTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE LTE LTE 009 009 UTE UTE UTE UTE UTE UTE UTE UTE 007 007 009 009 013 013 011 011 013 013 UTE UTE 01l 01l UTE UTE 013 013 009 009 015 015 015 015 015 015 015 015 009 009 UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTS LTS UTE UTE UTE UTE LTE LTE LTE LTE 012 012 012 012 UTE UTE 006 006 UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE UTE UTE UTE UTE LTE LTE UTE UTE LTE LTE 008 008 UTE UTE UTE UTE 008 008 008 008 LTE LTE WAR WAR WAR WAR TR WAR CL WAR WAR WAR 4039 4039 2071 4047 4047 2072 4047 4047 4047 2071 2072 2071 4047 4047 4047 4044 4044 2072 4044 2072 4095 4095 4095 4095 4095 4095 4095 2119 2119 2119 2119 2119 2119 2119 2119 2119 2119 2119 2118 2119 2119 2119 2119 2119 2119 4069 4003 4003 4003 4003 4003 4003 2026 4033 2025 2026 2026 2026 2026 2026 2026 2026 2026 2026 2026 2071 4039 4039 4044 4044 4044 2071 4044 4044 4047 OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET Page 98 of 155 PROBE 460SI 460S1 460HR 460S1 460S1 460HR 460S1 460SI 460SI 460HR 460HR 460HR 460S1 460S1 460SI 460SI 460S1 460HR 460S1 460HR 460S1 460SI 460S1 460S1 460S1 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460S1 460S1 460S1 460SI 460S1 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460S1 460S1 460S1 460S1 460HR 460S1 460S1 460S1

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 93 123 93 124 94 1

94 7

94 10 94 16 94 28 94 33 94 40 94 41 94 47 94 48 94 50 94 53 94 63 94 98 94 111 94 115 94 116 94 120 94 121 94 124 94 128 95 2

95 3

95 4

95 5

95 8

95 16 95 27 95 28 95 38 95 39 95 41 95 42 95 44 95 50 95 63 95 65 95 72 95 79 95 86 95 88 95 109 9.02 0.14 0.16 0.13

1. 55 0.28
1. 99 3.04 0.70 0.90 0.50 6.25 1.06
1. 06
1. 24 1.24 4.57 5.36
1. 85 3.52 0.51 0.51 0.26 0.30 0.93 2.34 1.27 1.24 0.33 6.80 0.52 5.05 0.95 0.94 2.75 0.45 7.92 9.14 7.93 0.15 1.25 0.06 5.47 2.82 4.07 2.83
1. 68 3.78 0.14 6.45 2.82
1. 24
1. 47
1. 47 2.81 2.16
1. 07 3.48 0.49 0.97 0.39 1.29 2.82 2.89 2.16
1. 78 3.24 2.20
1. 88 0.75 0.25
1. 79 2.02 0.44 0.26 ONT VOL VOL VOL TEA VOL TEA TEA 170 1 96 2

76 2

87 2

17 2

1152 23 2

28 2

o P 3 TWO 12 P 3 TWO 10 2

VOL 97 66 27 22 22 26 26 23 181 22 167 14 14 103 113 30 177 179 211 43 179 89 181 93 79 17 142 178 179 175 74 18 102 21 2

TEA 2

SAl 2

TWO 50 2

MAl 2

TWO 69 2

TEA 1

ONT 2

TEA 1

ONT 2

SAl 2

TWO 31 2

VOL 2

VOL 2

TEA 1

ONT 1

ONT 2

TEA P 3 TWO 9 1

ONT P 3 TWO 11 1

ONT P 3 TWO 15 P 3 TWO 15 2

TEA P 3 TWO 7 1

ONT 1

ONT 1

ONT 2

VOL 2

TEA 2

VOL 2

TEA 2

TEA 19 176 176 1 22 2

1 ONT ONT TEA ONT VOL ONT TEA 1

2 1

2 172 67 175 34 100 P 13 2

13 2

20 2

21 2

13 2

22 2

18 2

38 2

26 2

17 26 349 354 7

2 2

1 1

1 1

1 1

2 2

2 1

3 TWO 14 TWO 14 SVI TEA TEA TEA TEA VOL TEA VOL TEA TEA ONT ONT ONT ONT ONT ONT ONT VOL TEA ONT 8

10 13 7

28 34 180 111 31 P 3 TWO 9 P 3 TWO 7 UTE 013 014 014 UTE 010 UTE UTE 009 010 012 UTE UTE UTE UTE UTE UTE 013 UTE LTS UTE UTE 006 006 UTE LTE LTE UTE 008 LTE 010 UTE 010 008 UTE 008 LTE LTE UTE 013 UTE 006 UTE UTE LTE UTE UTE LTE 013 UTE UTE 010 UTE UTE UTE UTE UTE UTE LTS UTE LTS UTE UTE LTE LTE UTS UTS UTS UTS UTS 006 UTE LTE 002 008

-11.87

+1. 41

+0.94

+1.15

-0.14

+0.80

-0.17

-0.24

-0.75

-0.67

+0.80

-0.24

-3.57

-3.57

-3.57

-3.57

-0.13

+13.78

-0.06

-0.26

-3.55

-3.55

-0.14

-0.38

-0.17

+8.68

+7.37

-0.14

-0.65

+10.68

+0.58

-12.24

+0.68

-0.75

-0.20

-0.68

+11.21

+10.66

-11. 65

+1. 01

-0.14

+2.91 T0+14.62

-0.34

-0.25

+11.26

-11. 52

-0.20

+11.02

+1.00

-11. 60

-0.18

-0.60

-0.21

-0.21

-0.20

-0.16

-0.17

-0.15

+13.55

-0.11

+5.50

-0.22

-0.28

+8.23

+9.12

+6.79

+7.24

+9.03

+0.69

-1. 33

-0.33

-0.13

+10.38

+0.79

-0.70 05/02/02 13:29:59 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE 013 013 014 014 014 014 UTE UTE 010 010 UTE UTE UTE UTE 009 009 WAR 010 010 WAR 012 012 UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE 013 013 UTE UTE LTS LTS UTE UTS UTE UTS 006 006 006 006 UTE UTE LTE LTE LTE LTE UTE UTE 008 008 WAR LTE LTE 010 010 WAR UTE UTE 010 010 WAR 008 008 WAR UTE UTE 008 008 WAR LTE LTE LTE LTE UTE UTE 013 013 UTE UTE 006 006 UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE LTE LTE 013 013 UTE UTE UTE UTE 010 010 WAR UTE UTE UTE UTE CL UTE UTE UTE UTE UTE UTE UTE UTE LTS LTS UTE UTE LTS LTS UTE UTE UTE UTE LTE LTE LTE LTE UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS 006 006 UTE UTE LTE LTE 002 002 WAR 008 008 WAR 4047 4044 4044 4044 2069 4044 2070 2117 4095 4095 4095 2117 2117 2117 2127 2127 2119 4069 2118 4069 2127 2127 4064 4064 2118 4003 4003 2025 4039 4087 4087 4091 4044 4044 2069 4044 4044 4044 4044 4044 2124 4095 2117 2117 4095 4095 2117 4095 4095 4095 2117 4095 2117 2117 2117 2117 2117 2117 4064 2117 4064 2117 2116 4003 4003 4003 4003 4003 4003 4003 4051 2025 4033 4033 4039 OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET OUTLET OUTLET OUTLET Page 99 of 155 PROBE 460SI 460SI 460S1 460S1 460HR 460SI 460HR 460HR 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460S1 460HR 460HR 460SI 460S1 460HR 460S1 460S1 460HR 460S1 460SI 460S1 460S1 460S1 460S1 460HR 460S1 460SI 460S1 460SI 460S1 460HR 460SI 460HR 460HR 460S1 460S1 460HR 460SI 460SI 460S1 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460SI 460HR 460HR 460S1 460S1 460SI 460S1 460S1 460S1 460S1 460S1 460HR 460SI 460S1 460SI

Framatome ANP Inc.

05/02/02 13:30:00 Customer Name: Oconee Unit 1 Component: S/G B Page 100 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

95 110 0.12 1162 VOL 014

+15.66 014 014 4039 OUTLET 460S1 95 111 0.41 40 P 3 TWO 11 008

-0.65 008 008 WAR 4039 OUTLET 460S1 95 114 0.34 36 P 3 TWD 9 008

-0.65 008 008 WAR 4039 OUTLET 460S1 95 115 0.35 90 P 3 TWD 5 010

+0.62 010 010 WAR 4044 OUTLET 460S1 95 118 0.39 68 P 3 TWD 6 007

-0.62 007 007 WAR 4044 OUTLET 460S1 95 120 0.52 111 P 3 TWD 8 007

-0.70 007 007 WAR 4044 OUTLET 460S1

1. 61 21 2

TEA UTE

-0.14 UTE UTE 2070 INLET 460HR 95 121 0.44 134 P 3 TWO 9 007

-0.69 007 007 WAR 4044 OUTLET 460S1 95 122 0.60 71 P 3 TWO 10 007

-0.68 007 007 WAR 4044 OUTLET 460S1 95 124 0.56 61 P 3 TWO 9 009

-0.59 009 009 WAR 4044 OUTLET 460S1 1.26 15 2

TEA UTE

-0.15 UTE UTE 2069 INLET 460HR 95 125 15.99 186 1 ONT 008

-0.08 008 008 4044 OUTLET 460S1 95 126 10.09 180 1 ONT 009

-0.22 009 009 4044 OUTLET 460S1 95 127 0.51 52 P 3 TWO 8 010

+0.70 010 010 WAR 4044 OUTLET 460S1 96 1

0.52 45 2

SAl 010

+0.05 010 010 4095 OUTLET 460S1 0.52 45 2

TWO 87 010

+0.05 010 010 4095 OUTLET 460S1 3.99 23 2

TEA UTE

-0.29 UTE UTE 2117 INLET 460HR 96 2

2.29 23 2

TEA UTE

-0.28 UTE UTE 2116 INLET 460HR 96 3

6.31 171 1 ONT LTE

+11.29 LTE LTE 4095 OUTLET 460S1 0.14 81 2

VOL 006

+10.47 006 006 4095 OUTLET 460S1 0.32 25 2

VOL 014

+1.17 014 014 4095 OUTLET 460S1 0.18 258 9 PLP 014

+1.10 014 014 4095 OUTLET 460S1 5.71 165 1 DNT UTE

-10.50 UTE UTE 4095 OUTLET 460S1 3.16 22 2

TEA UTE

-0.24 UTE UTE 2116 INLET 460HR 96 4

32.94 48 1

MCI LTE

+1.00 LTE LTE 708 OUTLET 380EX 47.36 12 1

SCI LTE

+2.32 LTE LTE 708 OUTLET 380EX 96 5

5.79 170 1 ONT LTE

+11. 33 LTE LTE 4095 OUTLET 460S1 8.75 175 1 ONT UTE

-11.44 UTE UTE 4095 OUTLET 460S1 6.56 26 2

TEA UTE

-0.24 UTE UTE 2117 INLET 460HR 96 7

2.00 26 2

TEA UTE

-0.22 UTE UTE 2117 INLET 460HR 96 8

3.89 20 2

TEA UTE

-0.18 UTE UTE 2116 INLET 460HR 96 10 2.35 28 2

TEA UTE

-0.32 UTE UTE 2116 INLET 460HR 96 11 4.51 20 2

TEA UTE

-0.25 UTE UTE 2117 INLET 460HR 96 13 3.63 28 2

TEA UTE

-0.23 UTE UTE 2117 INLET 460HR 96 14 0.10 62 2

VOL 014

+1.15 014 014 4095 OUTLET 460S1 96 15 2.12 13 2

TEA UTE

-0.19 UTE UTE 2117 INLET 460HR 96 17

1. 92 186 1 ONT LTE

+2.81 LTE LTE 4095 OUTLET 460S1 0.27 81 P 3 TWO 8 008

+0.75 008 008 WAR 4095 OUTLET 460S1 0.84 30 2

TEA UTE

-0.25 UTE UTE 2117 INLET 460HR 96 18

1. 86 21 2

TEA UTE

-0.32 UTE UTE 2116 INLET 460HR 96 20 0.50 89 P 3 TWO 14 008

+0.73 008 008 WAR 4095 OUTLET 460S1 96 21 1.28 18 2

TEA UTE

-0.20 UTE UTE 2117 INLET 460HR 96 29 2.05 20 2

TEA UTE

-0.18 UTE UTE 2117 INLET 460HR 96 30 2.60 21 2

TEA UTE

-0.23 UTE UTE 2117 INLET 460HR 96 32

1. 43 16 2

TEA UTE

-0.13 UTE UTE 2117 INLET 460HR 96 43 0.65 16 2

ONT 014

+9.06 014 014 4064 INLET 460S1 96 44 0.76 41 2

TEA UTE

-0.12 UTE UTE 2117 INLET 460HR 96 45 2.88 21 2

TEA UTE

-0.23 UTE UTE 2116 INLET 460HR 96 46 2.95 168 1 ONT LTS

-0.08 LTS LTS 4064 INLET 460S1 96 47 2.89 22 2

TEA UTE

-0.15 UTE UTE 2116 INLET 460HR 96 49 2.96 23 2

TEA UTE

-0.17 UTE UTE 2114 INLET 460HR 96 53 4.70 28 2

TEA UTE

-0.07 UTE UTE 2114 INLET 460HR 96 56

1. 31 17 2

TEA UTE

-0.27 UTE UTE 2123 INLET 460HR 96 62 3.07 165 1 ONT LTE

+8.84 LTE LTE 4104 OUTLET 460S1 2.44 168 1 ONT LTE

+10.00 LTE LTE 4104 OUTLET 460SI 96 63 2.79 160 1 ONT LTE

+11.31 LTE LTE 4104 OUTLET 460S1 96 66

1. 22 16 2

TEA UTE

-0.20 UTE UTE 2026 INLET 460HR 96 75 0.20 115 2 VOL 006

-0.31 006 006 4051 OUTLET 460SI 3.34 26 2

TEA UTE

-0.20 UTE UTE 2026 INLET 460HR 96 76 2.39 179 1 ONT UTS

+4.94 UTS UTS 4033 OUTLET 460SI 2.91 178 1 ONT UTE

-10.15 UTE UTE 4033 OUTLET 460S1 0.67 23 2

TEA UTE

-0.22 UTE UTE 2025 INLET 460HR 96 108 0.60 51 P 3 TWO 15 008

+0.58 008 008 WAR 4039 OUTLET 460S1 96 110 0.64 50 P 3 TWO 16 008

-0.67 008 008 WAR 4039 OUTLET 460SI 96 113 0.21 43 P 3 TWO 6 008

-0.60 008 008 WAR 4039 OUTLET 460SI 96 116 0.62 0

P 3 TWO 10 014

+0.19 014 014 WAR 4044 OUTLET 460SI 0.18 82 2

VOL 014

+1. 07 014 014 4044 OUTLET 460S1 96 117 0.53 81 P 3 TWO 8 008

-0.70 008 008 WAR 4044 OUTLET 460S1 96 118 0.92 20 2

MAl UTE

-3.68 UTE UTS 2069 INLET 460HR 0.92 20 2

TWO 68 UTE

-3.68 UTE UTS 2069 INLET 460HR 96 119 0.95 96 P 3 TWO 15 007

-0.68 007 007 WAR 4044 OUTLET 460SI 0.64 85 P 3 TWO 10 010

+0.73 010 010 WAR 4044 OUTLET 460SI 0.64 59 2

VOL 010

+0.73 010 010 4044 OUTLET 460SI 96 120 6.82 178 1 ONT LTE

+12.15 LTE LTE 4044 OUTLET 460SI 0.43 91 P 3 TWO 7 008

+0.70 008 008 WAR 4044 OUTLET 460SI

Framatome ANP Inc.

05/02/02 13:30:01 Customer Name: Oconee Unit 1 Component: S/G B Page 101 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -: MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

0.13 23 2

VOL 010

+0.89 010 010 4044 OUTLET 460SI 10.00 184 1 DNT UTE

-8.49 UTE UTE 4044 OUTLET 46081 96 121 4.65 176 1 DNT LTE

+11.99 LTE LTE 4044 OUTLET 46081 0.92 97 p 3 TWD 14 007

-0.66 007 007 WAR 4044 OUTLET 46081

1. 01 90 P 3 TWD 16 010

+0.70 010 010 WAR 4044 OUTLET 460SI 8.00 176 1 DNT UTE

-8.49 UTE UTE 4044 OUTLET 460SI 96 122

11. 78 179 1 DNT 008

+0.48 008 008 4044 OUTLET 460SI 0.72 102 P 3 TWD 11 009

-0.67 009 009 WAR 4044 OUTLET 460SI 96 123 7.88 174 1 DNT LTE

+7.42 LTE LTE 4044 OUTLET 46081 12.14 176 1 DNT 008

+0.02 008 008 4044 OUTLET 460SI 9.97 173 1 DNT UTE

-12.55 UTE UTE 4044 OUTLET 46081 0.37 21 2

MAl UTE

-3.47 UTE UTS 2070 INLET 460HR 0.37 21 2

TWD 60 UTE

-3.47 UTE UTS 2070 INLET 460HR 97 1

4.62 28 2

TEA UTE

-0.38 UTE UTE 2116 INLET 460HR 97 3

7.73 174 1 DNT LTE

+11.13 LTE LTE 4095 OUTLET 460SI 5.68 173 1 DNT LTE

+12.07 LTE LTE 4095 OUTLET 46081 14.37 173 1 DNT 010

+0.57 010 010 4095 OUTLET 46081 5.38 176 1 DNT UTE

-9.86 UTE UTE 4095 OUTLET 460SI 8.35 177 1 DNT UTE

-10.44 UTE UTE 4095 OUTLET 460SI 4.53 174 1 DNT UTE

-11. 28 UTE UTE 4095 OUTLET 460SI 3.30 22 2

TEA UTE

-0.19 UTE UTE 2116 INLET 460HR 97 4

7.08 174 1 DNT LTE

+11. 01 LTE LTE 4095 OUTLET 46081 6.25 181 1 DNT UTE

-11.83 UTE UTE 4095 OUTLET 460SI 5.26 24 2

TEA UTE

-0.25 UTE UTE 2117 INLET 460HR 97 5

2.06 17 2

TEA UTE

-0.20 UTE UTE 2116 INLET 460HR 97 6

3.69 24 2

TEA UTE

-0.18 UTE UTE 2117 INLET 460HR 97 7

0.11 42 2

VOL 014

+0.87 014 014 4095 OUTLET 46081 97 8

5.38 25 2

TEA UTE

-0.17 UTE UTE 2117 INLET 460HR 97 9

5.26 19 2

TEA UTE

-0.34 UTE UTE 2116 INLET 460HR 97 10 4.06 28 2

TEA UTE

-0.20 UTE UTE 2117 INLET 460HR 97 11 1.68 32 2

TWD 97 UTE

-3.50 UTE UTS 2116 INLET 460HR

1. 68 32 2

SAl UTE

-3.50 UTE UTS 2116 INLET 460HR 97 13 0.09 82 2

VOL 014

+1. 24 014 014 4095 OUTLET 460S1 97 14 2.41 26 2

TEA UTE

-0.16 UTE UTE 2117 INLET 460HR 97 20 1.18 15 2

TEA UTE

-0.16 UTE UTE 2114 INLET 460HR 0.52 27 P 1 VOL UTE

-0.60 UTE UTE CS 2114 INLET 460HR 97 27 0.18 99 2

VOL UT8

+11.79 UT8 UTS 4064 INLET 460SI 97 28 1.19 15 2

TEA UTE

-0.18 UTE UTE 2114 INLET 460HR 97 30 0.94 14 2

TEA UTE

-0.16 UTE UTE 2114 INLET 460HR 97 32 1.82 21 2

TEA UTE

-0.16 UTE UTE 2114 INLET 460HR 0.57 28 2

8VI UTE

-0.49 UTE UTE CS 2114 INLET 460HR 0.57 29 P 4 TWD 95 UTE

-0.49 UTE UTE 2114 INLET 460HR 97 37 4.05 167 1 DNT LTE

+22.64 LTE 001 4113 OUTLET 520SI 2.55 166 1 DNT LT8

+2.21 LTE 001 4113 OUTLET 52081 3.14 167 1 DNT LT8

+3.17 LTE 001 4113 OUTLET 520SI 4.56 167 1 DNT LTS

-0.36 LTE 001 4113 OUTLET 520S1 3.72 26 2

TEA UTE

-0.22 UTE UTE 2115 INLET 460HR 97 41 3.55 188 1 DNT LTS

-10.29 LTS LTS 4064 INLET 460S1 97 51

1. 67 22 2

TEA UTE

-0.18 UTE UTE 2115 INLET 460HR 97 52 3.67 24 2

TEA UTE

-0.12 UTE UTE 2114 INLET 460HR 97 56 0.80 33 2

MAl UTE

-3.49 UTE UT8 2122 INLET 460HR 0.80 33 2

TWD 100 UTE

-3.49 UTE UTS 2122 INLET 460HR 1.23 27 2

TWD 78 UTE

-3.40 UTE UT8 2122 INLET 460HR 97 58

1. 42 171 1 DNT 005

-4.34 005 005 4104 OUTLET 460S1 97 70 0.20 108 2 VOL UTE

-5.20 UTE UTS 2030 INLET 460HR 97 75 2.61 14 2

TEA UTE

-0.13 UTE UTE 2026 INLET 460HR 97 89 3.54 18 2

TEA UTE

-0.16 UTE UTE 2026 INLET 460HR 97 95 0.87 26 2

TWD 66 UTE

-0.55 UTE UTE 2026 INLET 460HR 0.87 26 2

8VI UTE

-0.55 UTE UTE CL/C8 2026 INLET 460HR 97 109 0.7l 160 P 3 TWD 12 008

-0.66 008 008 WAR 4039 OUTLET 460S1 97 112 9.55 173 1 DNT 005

+5.49 005 005 4039 OUTLET 460S1 0.54 45 P 3 TWD 14 009

+0.64 009 009 WAR 4039 OUTLET 46081 5.12 174 1 DNT 010

+6.36 010 010 4039 OUTLET 460S1 97 114 1.11 127 P 3 TWD 21 010

+0.64 010 010 WAR 4044 OUTLET 46081 97 115 0.23 80 P 3 TWD 3 007

-0.67 007 007 WAR 4044 OUTLET 46081 0.53 82 P 3 TWD 9 008

+0.62 008 008 WAR 4044 OUTLET 46081 0.35 74 P 3 TWD 6 009

+0.53 009 009 WAR 4044 OUTLET 460S1 97 116 0.79 87 P 3 TWD 13 010

+0.67 010 010 WAR 4044 OUTLET 460S1 0.94 17 2

8AI UTE

-2.39 UTE UTE TR 2069 INLET 460HR 0.94 17 2

TWD 59 UTE

-2.39 UTE UTE 2069 INLET 460HR 97 117 0.23 102 P 3 TWD 4 008

-0.74 008 008 WAR 4044 OUTLET 460SI 97 118 0.30 133 P 3 TWD 5 007

-0.67 007 007 WAR 4044 OUTLET 46081 97 119 7.32 167 1 DNT LTE

+11.79 LTE LTE 4044 OUTLET 46081 8.84 168 1 DNT UTE

-8.57 UTE UTE 4044 OUTLET 46081 3.81 23 2

TEA UTE

-0.11 UTE UTE 2070 INLET 460HR

Framatome ANP Inc.

05/02/02 13:30:03 Customer Name: Oconee Unit 1 Component: S/G B Page 102 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -: MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

97 121 9.00 178 1 ONT UTE

-8.63 UTE UTE 4044 OUTLET 460SI 4.44 171 1 ONT LTE

+11. 93 LTE LTE 4087 OUTLET 460SI 3.03 19 2

TEA UTE

-0.12 UTE UTE 2069 INLET 460HR 97 122 6.22 175 1 ONT LTE

+7.36 LTE LTE 4033 OUTLET 460SI 6.34 174 1 ONT UTS

+11. 90 UTS UTS 4033 OUTLET 460SI 97 125 4.51 179 1 ONT LTE

+5.04 LTE LTE 4033 OUTLET 460SI 9.11 4

1 ONT 009

+0.25 009 009 4033 OUTLET 460SI 10.75 5

1 ONT 009

-0.47 009 009 4033 OUTLET 460SI 0.30 76 9

PLP 014

+1.18 014 014 4033 OUTLET 460SI 7.82 183 1 ONT UTE

-11.46 UTE UTE 4033 OUTLET 460SI 97 126 2.52 20 2

TEA UTE

-0.13 UTE UTE 2070 INLET 460HR 0.34 0

P 3 TWO 10 009

+0.84 009 009 WAR 4033 OUTLET 460SI 98 1

0.72 89 P 3 TWO 12 011

-0.70 011 011 WAR 4095 OUTLET 460SI 3.29 19 2

TEA UTE

-0.33 UTE UTE 2113 INLET 460HR 98 2

3.85 20 2

TEA UTE

-0.22 UTE UTE 2113 INLET 460HR 98 3

5.09 166 1 ONT LTE

+11.84 LTE LTE 4095 OUTLET 460SI 3.37 164 1 ONT UTE

-11.50 UTE UTE 4095 OUTLET 460SI 2.44 166 1 ONT UTE

-11. 87 UTE UTE 4095 OUTLET 460SI 98 5

4.28 168 1 ONT LTE

+11.41 LTE LTE 4095 OUTLET 460SI 0.09 99 2

VOL 005

-19.24 005 005 4095 OUTLET 460SI 7.83 175 1 ONT UTE

-12.23 UTE UTE 4095 OUTLET 460SI 2.68 26 2

TEA UTE

-0.21 UTE UTE 2113 INLET 460HR 98 6

1. 51 31 2

TEA UTE

-0.21 UTE UTE 2112 INLET 460HR 98 7

5.96 25 2

TEA UTE

-0.26 UTE UTE 2113 INLET 460HR 98 8

0.62 73 P 3 TWO 11 006

-0.33 006 006 WAR 4095 OUTLET 460SI 0.72 71 P 3 TWO 12 009

-0.77 009 009 WAR 4095 OUTLET 460SI 2.76 29 2

TEA UTE

-0.17 UTE UTE 2112 INLET 460HR 98 9

0.05 67 2

VOL 004

+1.15 004 004 4095 OUTLET 460SI 6.32 28 2

TEA UTE

-0.18 UTE UTE 2112 INLET 460HR 98 11 0.28 89 2

VOL 014

+1.26 014 014 4097 OUTLET 460SI 98 14 5.68 26 2

TEA UTE

-0.20 UTE UTE 2112 INLET 460HR 98 15 0.48 88 P 3 TWO 15 008

+0.62 008 008 WAR 4097 OUTLET 460SI 98 18 0.08 165 P 3 TWO 3 009

-0.68 009 009 WAR 4097 OUTLET 460SI

1. 76 22 2

TEA UTE

-0.14 UTE UTE 2112 INLET 460HR 98 19 6.89 23 2

TEA UTE

-0.21 UTE UTE 2113 INLET 460HR 98 20 6.79 29 2

TEA UTE

-0.17 UTE UTE 2112 INLET 460HR 98 25

1. 67 24 2

TEA UTE

-0.16 UTE UTE 2113 INLET 460HR 98 26 3.32 28 2

TEA UTE

-0.13 UTE UTE 2112 INLET 460HR 98 30 3.96 27 2

TEA UTE

-0.19 UTE UTE 2112 INLET 460HR 98 33 2.70 17 2

TEA UTE

-0.23 UTE UTE 2113 INLET 460HR 98 34 2.91 28 2

TEA UTE

-0.17 UTE UTE 2112 INLET 460HR 98 37 4.78 22 2

TEA UTE

-0.17 UTE UTE 2113 INLET 460HR 98 40 3.36 28 2

TEA UTE

-0.16 UTE UTE 2112 INLET 460HR 98 42

1. 93 166 1 ONT LTE

+10.82 LTE LTS 4113 OUTLET 520SI 98 44 4.92 25 2

TEA UTE

-0.14 UTE UTE 2112 INLET 460HR 98 47

1. 98 19 2

TEA UTE

-0.23 UTE UTE 2113 INLET 460HR 98 58 6.72 164 1 ONT UTE

-4.86 UTE UTE 4104 OUTLET 460SI 4.89 164 1 ONT UTE

-6.13 UTE UTE 4104 OUTLET 460SI 98 62 6.10 176 1 ONT LTS

-14.29 LTS LTS 4104 OUTLET 460SI 3.07 176 1 ONT LTS

-15.19 LTS LTS 4104 OUTLET 460SI 3.01 166 1 ONT LTS

+2.37 LTS LTS 4104 OUTLET 460SI 98 63 4.73 172 1 ONT LTE

+8.30 LTE LTE 4104 OUTLET 460SI 98 71 0.16 77 2

VOL 013

+16.61 013 013 4051 OUTLET 460SI 98 74 0.34 120 2 VOL 006

+0.50 006 006 4051 OUTLET 460SI 98 78 8.16 172 1 ONT 013

+11. 98 013 013 4029 OUTLET 460SI 98 98 2.19 18 2

TEA UTE

-0.33 UTE UTE 2030 INLET 460HR 98 103 0.54 0

P 3 TWO 15 008

-0.74 008 008 WAR 4033 OUTLET 460SI 98 104 0.36 0

P 3 TWO 11 008

-0.63 008 008 WAR 4033 OUTLET 460SI 98 106 3.96 18 2

TEA UTE

-0.16 UTE UTE 2029 INLET 460HR 98 110 0.24 0

P 3 TWO 8 008

-0.77 008 008 WAR 4033 OUTLET 460SI 0.27 170 P 3 TWO 5 008

+0.70 008 008 WAR 4033 OUTLET 460SI 98 112 2.25 22 2

TEA UTE

-0.16 UTE UTE 2069 INLET 460HR 98 116

1. 61 12 2

TEA UTE

-0.15 UTE UTE 2069 INLET 460HR 0.39 0

P 3 TWO 12 008

-0.80 008 008 WAR 4033 OUTLET 460SI 98 117 0.44 0

P 3 TWO 13 008

+0.50 008 008 WAR 4033 OUTLET 460SI 0.57 158 P 3 TWO 12 010

+0.67 010 010 WAR 4033 OUTLET 460SI 0.31 160 P 3 TWO 6 012

-0.73 012 012 WAR 4033 OUTLET 460SI 0.16 51 2

VOL 014

+1. 09 014 014 4033 OUTLET 460SI 98 118 0.38 0

P 3 TWO 11 009

-0.70 009 009 WAR 4033 OUTLET 460SI 98 120

1. 92 37 2

TEA UTE

-0.25 UTE UTE 2069 INLET 460HR

1. 98 174 1 ONT LTE

+11.15 LTE LTE 4033 OUTLET 460SI 8.66 178 1 ONT LTE

+11. 69 LTE LTE 4033 OUTLET 460SI 0.65 76 P 3 TWO 12 006

-0.69 006 006 WAR 4033 OUTLET 460SI 6.86 179 1 DNT UTE

-8.36 UTE UTE 4033 OUTLET 460SI 98 121 0.89 28 2

SAl UTE

-3.45 UTE UTS 2070 INLET 460HR

Framatome ANP Inc.

Customer Name: Oconee unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION 98 98 98 98 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 122 123 126 127 1

3 5

6 7

9 10 12 14 22 23 25 27 28 31 38 42 47 49 50 53 55 60 68 69 72 78 83 85 99 103 106 110 111 114 0.89 8.67 9.16 2.94 0.24 9.08 0.19 9.20 7.51 5.98 10.47 0.34 8.56 0.50 0.33 6.94 3.50 0.29 4.34 3.85 2.06 0.22 3.04 3.27 3.33 0.12 4.53 0.95 1.26 0.14 1.71 3.88 0.37

1. 48 0.20 3.28 4.46 4.50 6.79 2.37 5.13 4.25 0.34 0.97 0.97 0.54 2.19 0.27 0.27 2.65 0.73 0.73 1.13 0.00 0.16 0.33 0.73 0.97 1.14 1.72 2.30 2.33 2.26
1. 90 1.10 0.70 0.00 4.33 2.21 3.78 2.97 4.67 0.29 1.14 0.38 28 182 1

19 o

183 o

177 181 178 180 157 o

154 89 21 179 47 178 30 29 137 26 22 27 105 30 17 13 99 21 30 20 29 o

24 24 22 27 2

TWD 85 1

DNT 1

DNT 2

TEA P 3 TWD 7 1

DNT P 3 TWD 6 1

DNT 1

DNT 1

DNT 1

DNT P 3 TWO 7 1

DNT P 3 TWD 11 P 3 TWD 7 2

TEA 1

DNT P 3 TWD 10 1

DNT 2

TEA 2

TEA P 3 TWD 6 2

TEA 2

TEA 2

TEA P 3 TWD 4 2

TEA 2

TEA 2

TEA 2

VOL 2

TEA 2

TEA 2

VOL 2

TEA P 3 TWD 4 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 20 170 187 116 P 21 2

21 2

18 2

18 2

68 2

68 2

25 2

20 2

20 2

28 1

DNT 1

DNT 3 TWO 8 TWD 58 MAl TWD 49 TEA SAl P 1 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 1

TWD 52 TEA TWD 63 MAl SCI o

91 65 29 26 24 29 28 26 31 42 45 33 o

171 174 20 27 27 137 162 73 1

2 2

2 TWD 0 2

5 13 18 22 40 65 66 62 46 21 12 o

TWD TWO TWO TWO TWD TWD TWO TWO TWO TWO TWO TWD TWO ONT ONT TEA TEA TEA P 3 TWO 7 P 3 TWD 22 P 3 TWO 9 UTE LTE UTE UTE 006 LTE 008 UTE LTE LTE LTE 011 UTE 010 010 UTE LTE 014 UTE UTE UTE 008 UTE UTE UTE 009 UTE UTE UTE 014 UTE UTE UTS UTE 007 UTE UTE UTE UTE UTE 015 015 007 UTE UTE UTE UTE 010 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE 013 UTE UTE UTE 008 010 008

-3.45

+10.79

-7.58

-0.25

+0.42

+7.30

+0.51

-11.41

+4.95

+7.48

+11. 07

+0.79

-11.86

+0.76

-0.79

-0.32

+11.20

+0.81

-11.85

-0.19

-0.16

-0.57

-0.16

-0.13

-0.17

-0.64

-0.15

-0.11

-0.22

-0.16

-0.27

-0.14

-1. 34

-0.13

+0.04

-0.11

-0.20

-0.13

-0.16

-0.17

+12.63

+11.62

-0.42

-3.49

-3.49

-3.57

-0.36

+11.43

+11.43

-0.19

-3.63

-3.63

-0.24

-0.24

-0.24

-0.24

-0.24

-0.24

-0.24

-0.24

-0.24

-0.24

-0.24

-0.24

-0.24

-0.24

-0.24

+8.48

+19.22

-0.15

-0.33

-0.22

-0.71

+0.72

-0.73 TO+198.0 TO+207.0 TO+216.0 TO+225.0 TO+234.0 TO+243.0 TO+252.0 TO+261.0 TO+270.0 TO+279.0 TO+288.0 TO+297.0 TO+306.0 TO+315.0 05/02/02 13:30:04 Component: S/G B Page 103 of 155 EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE UTE UTS LTE LTE UTE UTE UTE UTE 006 006 LTE LTE 008 008 UTE UTE LTE LTE LTE LTE LTE LTE 011 011 UTE UTE 010 010 010 010 UTE UTE LTE LTE 014 014 UTE UTE UTE UTE UTE UTE 008 008 UTE UTE UTE UTE UTE UTE 009 009 UTE UTE UTE UTE UTE UTE 014 014 UTE UTE UTE UTE UTS UTS UTE UTE 007 007 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 015 015 015 015 007 007 UTE UTS UTE UTS UTE UTS UTE UTE 010 010 010 010 UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS LTE LTE 013 013 UTE UTE UTE UTE UTE UTE 008 008 010 010 008 008 WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR TR CL WAR WAR WAR 2070 4033 4033 2069 4033 4033 4033 4033 4033 4033 4033 4033 4033 4033 4033 2113 4097 4097 4097 2112 2112 4097 2113 2112 2112 4097 2113 2113 2113 4064 2112 2112 4064 2113 4064 2113 2113 2112 2112 2113 4069 4069 4069 2122 2122 2122 2030 4051 4051 2029 2029 2029 2030 2030 2030 2030 2030 2030 2030 2030 2030 2030 2030 2030 2030 2030 2030 4029 4029 2030 2030 2029 4029 4029 4029

===

INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET 460HR 460SI 460S1 460HR 460S1 460S1 460SI 460S1 460S1 460S1 460S1 460S1 460SI 460S1 460S1 460HR 460S1 460S1 460S1 460HR 460HR 460S1 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460S1 460HR 460HR 460SI 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460SI 460S1 460S1 460HR 460HR 460HR 460HR 460S1 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460S1 460HR 460HR 460HR 460S1 460S1 460S1

Framatome ANP Inc.

05/02/02 13:30:05 Customer Name: Oconee Unit 1 Component: S/G B Page 104 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

0.53 65 P 3 TWD 12 009

-0.60 009 009 WAR 4029 OUTLET 460SI 99 116 2.75 23 2

TEA UTE

-0.17 UTE UTE 2069 INLET 460HR 99 117 3.66 19 2

TEA UTE

-0.15 UTE UTE 2070 INLET 460HR 0.22 42 2

VOL 011

-1.12 Oll Oll 4029 OUTLET 460S1 99 118 1.32 19 2

TEA UTE

-0.20 UTE UTE 2069 INLET 460HR 0.16 74 9

PLP 014

+1.07 014 014 4029 OUTLET 460S1 0.17 74 2

VOL 014

+0.81 014 014 4029 OUTLET 460SI 99 120 1.29 24 2

TEA UTE

-0.16 UTE UTE 2069 INLET 460HR 99 121 7.05 24 2

TEA UTE

-0.13 UTE UTE 2070 INLET 460HR 0.71 23 2

SAl UTE

-l. 97 UTE UTE CS 2070 INLET 460HR 0.71 23 2

TWD 67 UTE

-1. 97 UTE UTE 2070 INLET 460HR

11. 19 174 1 DNT 009

-0.24 009 009 4029 OUTLET 46081 99 122 8.24 176 1 DNT LTE

+10.81 LTE LTE 4029 OUTLET 46081 12.06 180 1 DNT 009

-0.44 009 009 4029 OUTLET 460S1 100 1 0.23 71 2

VOL 002

+0.64 002 002 4097 OUTLET 460SI 3.35 29 2

TEA UTE

-0.37 UTE UTE 2127 INLET 460HR 100 2 8.47 165 1 DNT UT8

+12.85 UTE UT8 4113 OUTLET 52081 4.32 175 1 DNT LTE

+10.89 LTE LTE 4097 OUTLET 46081 5.27 166 1 DNT UTE

-1l.60 UTE UTE 4097 OUTLET 46081 100 4 5.06 173 1 DNT LTE

+1l.14 LTE LTE 4097 OUTLET 460S1 2.97 164 1 DNT LTE

+10.60 LTE LTE 4097 OUTLET 460S1 6.16 178 1 DNT UTE

-12.03 UTE UTE 4097 OUTLET 46081 100 5 3.06 174 1 DNT LTE

+11.32 LTE LTE 4097 OUTLET 460S1 7.12 168 1 DNT UTE

-12.04 UTE UTE 4097 OUTLET 460S1 2.43 26 2

TEA UTE

-0.15 UTE UTE 2112 INLET 460HR 100 6 l.96 170 1 DNT LTS

+4.91 LTS LT8 4097 OUTLET 46081 2.36 17 2

TEA UTE

-0.17 UTE UTE 2113 INLET 460HR 100 7 1.34 29 2

TEA UTE

-0.17 UTE UTE 2112 INLET 460HR 100 8 0.18 82 2

VOL 004

+0.90 004 004 4097 OUTLET 460S1 2.32 21 2

TEA UTE

-0.14 UTE UTE 2113 INLET 460HR 100 12 0.26 56 P 3 TWD 9 009

+0.69 009 009 WAR 4097 OUTLET 460SI 0.68 80 P 3 TWD 17 009

-0.78 009 009 WAR 4097 OUTLET 46081 100 13

1. 82 24 2

TEA UTE

-0.14 UTE UTE 2112 INLET 460HR 100 14 1.57 21 2

TEA UTE

-0.20 UTE UTE 2113 INLET 460HR 100 15 3.91 178 1 DNT UTE

-7.03 UTE UTE 4097 OUTLET 460S1 100 16 2.82 23 2

TEA UTE

-0.15 UTE UTE 2113 INLET 460HR 100 17 5.48 31 2

TEA UTE

-0.19 UTE UTE 2112 INLET 460HR 100 18 2.61 27 2

TEA UTE

-0.20 UTE UTE 2113 INLET 460HR 100 20 4.85 26 2

TEA UTE

-0.21 UTE UTE 2113 INLET 460HR 100 23 0.38 25 2

VOL 015

-10.01 015 015 4064 INLET 46081 100 27 3.53 27 2

TEA UTE

-0.18 UTE UTE 2112 INLET 460HR 100 28 5.96 28 2

TEA UTE

-0.26 UTE UTE 2113 INLET 460HR 100 32 0.82 20 2

VOL 003

+18.65 003 003 4064 INLET 460SI 100 33 l.16 17 2

TEA UTE

-0.17 UTE UTE 2112 INLET 460HR 100 37 3.19 26 2

TEA UTE

-0.25 UTE UTE 2112 INLET 460HR 100 39 l.23 24 2

TEA UTE

-0.20 UTE UTE 2112 INLET 460HR 100 41 2.06 169 1 DNT LTE

+9.75 LTE LT8 4113 OUTLET 520S1 2.62 169 1 DNT LTE

+8.78 LTE LT8 4113 OUTLET 520S1 3.56 24 2

TEA UTE

-0.17 UTE UTE 2112 INLET 460HR 100 42 2.62 20 2

TEA UTE

-0.16 UTE UTE 2113 INLET 460HR 100 44 5.50 30 2

TEA UTE

-0.15 UTE UTE 2113 INLET 460HR 100 47 1.25 27 2

TEA UTE

-0.18 UTE UTE 2112 INLET 460HR 100 48 1.72 21 2

TEA UTE

-0.18 UTE UTE 2113 INLET 460HR 100 54 1.28 24 2

TEA UTE

-0.13 UTE UTE 2113 INLET 460HR 100 55 7.89 26 2

TEA UTE

-0.14 UTE UTE 2112 INLET 460HR 100 62 2.62 161 1 DNT LTE

+8.80 LTE LTE 4104 OUTLET 460S1 100 65 0.99 18 2

TWD 42 UTE

-1. 41 UTE UTS 2030 INLET 460HR 0.99 18 2

SVI UTE

-1. 41 UTE UTS TR 2030 INLET 460HR 100 66

1. 81 180 1 DNT LTS

-9.09 LTS LTS 4049 OUTLET 46081 1.10 182 1 DNT LTS

-9.67 LTS LTS 4049 OUTLET 46081 100 67 7.20 171 1 DNT 014

+14.36 014 014 4051 OUTLET 46081 100 70 0.52 20 2

TWD 63 UTE

-3.92 UTE UT8 2029 INLET 460HR 0.52 20 2

MAl UTE

-3.92 UTE UT8 TR 2029 INLET 460HR 100 85 3.41 19 2

TEA UTE

-0.16 UTE UTE 2030 INLET 460HR 100 88 3.66 20 2

TEA UTE

-0.20 UTE UTE 2029 INLET 460HR 100 89 2.69 22 2

TEA UTE

-0.24 UTE UTE 2030 INLET 460HR 100 92 0.66 l3 P 1 SCI UTE

-3.86 UTE UTS TR 2029 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-3.86 TO+93.3 UTE UTS 2029 INLET 460HR 0.37 33 P 3 TWD 63 UTE

-3.86 TO+84.4 UTE UT8 2029 INLET 460HR 0.44 25 P 3 TWD 73 UTE

-3.86 TO+75.6 UTE UT8 2029 INLET 460HR 0.39 24 P 3 TWD 66 UTE

-3.86 TO+66.7 UTE UT8 2029 INLET 460HR 0.39 21 P 3 TWD 66 UTE

-3.86 TO+57.8 UTE UT8 2029 INLET 460HR 0.36 23 P 3 TWD 61 UTE

-3.86 TO+48.9 UTE UTS 2029 INLET 460HR 0.32 41 P 3 TWD 56 UTE

-3.86 TO+40.0 UTE UTS 2029 INLET 460HR 0.35 34 P 3 TWD 60 UTE

-3.86 TO+31.1 UTE UTS 2029 INLET 460HR

Framatome ANP Inc.

05/02/02 13:30:06 Customer Name: Oconee unit 1 Component: S/G B Page 105 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -: MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

==;:::::;::

============

::;:==:::;===

0.38 33 P 3 TWO 65 UTE

-3.86 TO+22.2 UTE UTS 2029 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.86 TO+13.3 UTE UTS 2029 INLET 460HR 100 97

1. 74 48 2

TEA UTE

-0.23 UTE UTE 2030 INLET 460HR 100 103 3.95 25 2

TEA UTE

-0.34 UTE UTE 2030 INLET 460HR 100 106 6.24 23 2

TEA UTE

-0.18 UTE UTE 2029 INLET 460HR 100 108 0.49 25 2

MAl UTE

-3.62 UTE UTS TR 2029 INLET 460HR 0.49 25 2

TWO 81 UTE

-3.62 UTE UTS 2029 INLET 460HR 100 111 0.87 162 P 3 TWO 18 010

+0.71 010 010 WAR 4029 OUTLET 460S1 100 115 2.75 21 2

TEA UTE

-0.15 UTE UTE 2070 INLET 460HR

1. 00 156 P 3 TWO 20 010

-0.76 010 010 WAR 4029 OUTLET 460S1 0.71 165 P 3 TWO 15 012

-0.72 012 012 WAR 4029 OUTLET 460S1 100 116 3.17 28 2

TEA UTE

-0.17 UTE UTE 2069 INLET 460HR 100 117 2.43 24 2

TEA UTE

-0.17 UTE UTE 2070 INLET 460HR 100 118 1.12 17 2

TEA UTE

-0.15 UTE UTE 2069 INLET 460HR 100 120 6.87 184 1 ONT UTE

-12.16 UTE UTE 4091 OUTLET 460S1 8.59 177 1 ONT LTE

+10.97 LTE LTE 4029 OUTLET 460S1 12.03 177 1 ONT 009

+0.01 009 009 4029 OUTLET 460S1 6.98 183 1 ONT 009

+0.61 009 009 4029 OUTLET 460S1 0.20 62 2

VOL 014

+1.01 014 014 4029 OUTLET 460SI 100 125 4.45 183 1 ONT UTE

-11. 44 UTE UTE 4091 OUTLET 460S1 5.81 185 1 ONT UTE

-10.12 UTE UTE 4091 OUTLET 460S1 3.03 161 1 ONT LTE

+7.93 LTE LTE 4029 OUTLET 460S1 4.60 162 1 ONT LTE

+10.38 LTE LTE 4029 OUTLET 460S1 4.17 173 1 ONT LTE

+11. 46 LTE LTE 4029 OUTLET 460S1 4.94 160 1 ONT 001

+0.75 001 001 4029 OUTLET 460SI 0.39 168 P 3 TWO 9 010

-0.80 010 010 WAR 4029 OUTLET 460S1 0.78 163 P 3 TWO 16 010

-0.13 010 010 WAR 4029 OUTLET 460S1 0.63 164 P 3 TWO 14 010

+0.60 010 010 WAR 4029 OUTLET 460S1 0.15 69 9

PLP 014

+1. 81 014 014 4029 OUTLET 460S1 0.12 59 2

VOL 014

+1.12 014 014 4029 OUTLET 460S1 101 1 0.12 41 2

VOL 012

+1. 67 012 012 4097 OUTLET 460S1 2.92 22 2

TEA UTE

-0.25 UTE UTE 2113 INLET 460HR 101 2 10.52 171 1 ONT LTE

+10.89 LTE LTE 4097 OUTLET 460S1 7.92 169 1 ONT UTE

-12.22 UTE UTE 4097 OUTLET 460S1 101 3 7.04 177 1 ONT LTE

+11.30 LTE LTE 4097 OUTLET 460S1

11. 77 174 1 ONT 010

-0.37 010 010 4097 OUTLET 460S1 7.58 173 1 ONT UTE

-12.19 UTE UTE 4097 OUTLET 460S1 5.23 30 2

TEA UTE

-0.19 UTE UTE 2112 INLET 460HR 101 5 4.13 173 1 ONT LTE

+11.19 LTE LTE 4097 OUTLET 460S1 7.50 176 1 ONT UTE

-11.87 UTE UTE 4097 OUTLET 460S1 7.65 179 1 ONT UTE

-12.34 UTE UTE 4097 OUTLET 460S1 101 6 2.71 31 2

TEA UTE

-0.22 UTE UTE 2112 INLET 460HR 101 9 3.14 30 2

TEA UTE

-0.25 UTE UTE 2113 INLET 460HR 101 10 5.29 29 2

TEA UTE

-0.19 UTE UTE 2112 INLET 460HR 101 11

1. 74 25 2

TEA UTE

-0.26 UTE UTE 2113 INLET 460HR 101 12 3.63 27 2

TEA UTE

-0.17 UTE UTE 2112 INLET 460HR 101 13 4.45 27 2

TEA UTE

-0.24 UTE UTE 2113 INLET 460HR 101 16 0.13 109 P 3 TWO 5 009

-0.60 009 009 WAR 4097 OUTLET 460S1 101 18

1. 77 19 2

TEA UTE

-0.25 UTE UTE 2113 INLET 460HR 101 25 0.70 19 2

SAl UTE

-1. 20 UTE UTE CL 2113 INLET 460HR 0.70 19 2

TWO 56 UTE

-1.20 UTE UTE 2113 INLET 460HR 101 27

1. 74 19 2

TEA UTE

-0.31 UTE UTE 2113 INLET 460HR 101 29 7.02 23 2

TEA UTE

-0.27 UTE UTE 2113 INLET 460HR 101 36 2.63 210 2 TEA UTE

-0.19 UTE UTE 2112 INLET 460HR 101 37 3.52 22 2

TEA UTE

-0.18 UTE UTE 2113 INLET 460HR 101 38 3.84 27 2

TEA UTE

-0.24 UTE UTE 2112 INLET 460HR 101 39 0.12 116 2 VOL 012

+5.08 012 012 4064 INLET 460SI 101 43 2.19 25 2

TEA UTE

-0.18 UTE UTE 2113 INLET 460HR 101 44

1. 77 36 2

SAl UTE

-3.52 UTE UTS 2127 INLET 460HR

1. 77 36 2

TWO 99 UTE

-3.52 UTE UTS 2127 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-1. 45 TO+245.9 UTE UTS 2127 INLET 460HR

1. 37 25 P 3 TWO 51 UTE

-1. 45 TO+254.6 UTE UTS 2127 INLET 460HR 2.13 25 P 3 TWO 85 UTE

-1. 45 TO+263.4 UTE UTS 2127 INLET 460HR 2.36 29 P 1 SCI UTE

-1. 45 UTE UTS TR 2127 INLET 460HR 2.35 29 P 3 TWO 96 UTE

-1. 45 TO+272.2 UTE UTS 2127 INLET 460HR 2.23 22 P 3 TWO 90 UTE

-1. 45 TO+281.0 UTE UTS 2127 INLET 460HR

1. 87 22 P 3 TWO 73 UTE

-1. 45 TO+289.8 UTE UTS 2127 INLET 460HR 1.08 24 P 3 TWO 39 UTE

-1. 45 TO+298.5 UTE UTS 2127 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-1. 45 TO+307.3 UTE UTS 2127 INLET 460HR 101 48 3.57 20 2

TEA UTE

-0.19 UTE UTE 2113 INLET 460HR 101 49 0.91 24 2

SAl UTE

-3.50 UTE UTS 2112 INLET 460HR 0.91 24 2

TWO 65 UTE

-3.50 UTE UTS 2112 INLET 460HR 101 51 0.75 31 2

SAl UTE

-3.53 UTE UTS 2112 INLET 460HR 0.75 31 2

TWD 89 UTE

-3.53 UTE UTS 2112 INLET 460HR 101 54 0.12 56 2

VOL 002

-8.77 002 002 4069 INLET 460SI

Framatome ANP Inc.

05/02/02 13:30:07 Customer Name: Oconee Unit 1 Component: S/G B Page 106 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -: MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

101 59 5.02 157 1 DNT UTS

+8.89 UTS UTS 4104 OUTLET 460SI 4.18 162 1 DNT UTS

+7.79 UTS UTS 4104 OUTLET 460S1 0.70 171 1 DNT UTS

+6.43 UTS UTS 4104 OUTLET 460SI 101 61 2.47 27 2

TEA UTE

-0.19 UTE UTE 2122 INLET 460HR 101 71 0.31 26 2

TWD 84 UTE

-3.55 UTE UTS TR 2029 INLET 460HR 0.32 27 2

SAl UTE

-3.55 UTE UTS TR 2029 INLET 460HR 101 75 0.72 24 2

SAl UTE

-1. 08 UTE UTE TR 2029 INLET 460HR 0.70 23 2

TWD 72 UTE

-1. 08 UTE UTE TR 2029 INLET 460HR 101 77

1. 07 20 2

MAl UTE

-3.95 UTE UTS TR 2029 INLET 460HR

1. 07 20 2

TWD 63 UTE

-3.95 UTE UTS 2029 INLET 460HR 101 79

1. 08 11 2

MAl UTE

-3.71 UTE UTS TR 2029 INLET 460HR 1.08 11 2

TWD 33 UTE

-3.71 UTE UTS 2029 INLET 460HR 101 82 2.38 18 2

TEA UTE

-0.24 UTE UTE 2030 INLET 460HR 101 87

1. 64 167 1 DNT LTE

+9.46 LTE LTE 4029 OUTLET 460S1 101 96

1. 92 22 2

TEA UTE

-0.25 UTE UTE 2030 INLET 460HR 101 104 0.55 152 P 3 TWD 12 008

+0.66 008 008 WAR 4029 OUTLET 460SI 101 107 3.84 22 2

TEA UTE

-0.18 UTE UTE 2029 INLET 460HR 101 109

1. 02 22 2

MAl UTE

-3.50 UTE UTS 2069 INLET 460HR

1. 02 22 2

TWD 75 UTE

-3.50 UTE UTS 2069 INLET 460HR 0.96 164 P 3 TWD 19 010

+0.75 010 010 WAR 4029 OUTLET 460S1 101 110 2.77 20 2

TEA UTE

-0.16 UTE UTE 2069 INLET 460HR 101 III 2.92 25 2

TEA UTE

-0.14 UTE UTE 2070 INLET 460HR 0.27 22 P 3 TWD 6 008

-0.68 008 008 WAR 4029 OUTLET 460S1 101 113 0.80 161 P 3 TWD 17 010

-0.75 010 010 WAR 4029 OUTLET 460S1 101 114

1. 84 22 2

TEA UTE

-0.18 UTE UTE 2069 INLET 460HR 101 115

1. 55 22 2

TEA UTE

-0.14 UTE UTE 2070 INLET 460HR 0.55 151 P 3 TWD 12 007

+0.73 007 007 WAR 4029 OUTLET 460S1 101 117 2.68 24 2

TEA UTE

-0.18 UTE UTE 2069 INLET 460HR 101 118 2.96 23 2

TEA UTE

-0.20 UTE UTE 2069 INLET 460HR 5.24 179 1 DNT 009

+0.44 009 009 4029 OUTLET 460S1 101 119 7.16 185 1 DNT UTE

-11. 97 UTE UTE 4091 OUTLET 460S1 2.71 19 2

TEA UTE

-0.15 UTE UTE 2070 INLET 460HR

1. 37 181 1 DNT LTE

+10.72 LTE LTE 4029 OUTLET 460S1 8.75 180 1 DNT LTE

+11.79 LTE LTE 4029 OUTLET 460S1 7.11 176 1 DNT 009

+0.70 009 009 4029 OUTLET 460S1 0.35 62 2

VOL 014

+0.75 014 014 4029 OUTLET 460S1 101 121

11. 84 IS 1

SCI LTE

+3.00 LTE LTE 710 OUTLET 380EX 102 2 0.11 92 2

VOL 014

+1. 34 014 014 4097 OUTLET 460S1 102 3 10.09 173 1 DNT LTE

+11.39 LTE LTE 4097 OUTLET 460S1 7.80 176 1 DNT LTE

+13.53 LTE LTE 4097 OUTLET 460S1 5.28 173 1 DNT UTE

-12.03 UTE UTE 4097 OUTLET 460S1 1.82 168 1 DNT UTE

-11.77 UTE UTE 4097 OUTLET 460S1

1. 21 22 2

MAl UTE

-3.55 UTE UTS 2113 INLET 460HR 1.21 22 2

TWD 68 UTE

-3.55 UTE UTS 2113 INLET 460HR 102 4 7.62 171 1 DNT LTE

+10.35 LTE LTE 4097 OUTLET 460S1 6.12 173 1 DNT LTE

+11.18 LTE LTE 4097 OUTLET 460S1 0.47 84 P 3 TWD 13 009

-0.76 009 009 WAR 4097 OUTLET 460S1 5.24 171 1 DNT UTE

-11.34 UTE UTE 4097 OUTLET 460S1 8.28 174 1 DNT UTE

-12.28 UTE UTE 4097 OUTLET 460S1 2.49 37 2

TEA UTE

-0.19 UTE UTE 2112 INLET 460HR 102 7

1. 36 29 2

SAl UTE

-3.55 UTE UTS 2112 INLET 460HR

1. 36 29 2

TWD 82 UTE

-3.55 UTE UTS 2112 INLET 460HR 102 10 0.21 122 P 3 TWD 8 011

-0.63 011 011 WAR 4097 OUTLET 460SI 0.50 144 P 3 TWD 16 013

-0.66 013 013 WAR 4097 OUTLET 460S1 102 14 2.18 171 1 DNT UTE

-8.75 UTE UTE 4097 OUTLET 460S1 2.31 169 1 DNT UTE

-9.48 UTE UTE 4097 OUTLET 460S1 102 19 0.77 24 P 1 SCI UTE

-3.65 UTE UTS 2113 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-3.65 TO+333.0 UTE UTS 2113 INLET 460HR 0.33 100 P 3 TWD 39 UTE

-3.65 To+342.0 UTE UTS 2113 INLET 460HR 0.61 53 P 3 TWD 73 UTE

-3.65 TO+351. 0 UTE UTS 2113 INLET 460HR 0.65 47 P 3 TWD 78 UTE

-3.65 TO+O.O UTE UTS 2113 INLET 460HR 0.65 47 P 3 TWD 77 UTE

-3.65 TO+9.0 UTE UTS 2113 INLET 460HR 0.61 52 P 3 TWD 73 UTE

-3.65 TO+l8.0 UTE UTS 2113 INLET 460HR 0.50 56 P 3 TWD 59 UTE

-3.65 TO+27.0 UTE UTS 2113 INLET 460HR 0.38 63 P 3 TWD 46 UTE

-3.65 TO+36.0 UTE UTS 2113 INLET 460HR 0.36 63 P 3 TWD 44 UTE

-3.65 TO+45.0 UTE UTS 2113 INLET 460HR 0.32 72 P 3 TWD 39 UTE

-3.65 TO+54.0 UTE UTS 2113 INLET 460HR 0.26 104 P 3 TWD 31 UTE

-3.65 TO+63.0 UTE UTS 2113 INLET 460HR 0.29 97 P 3 TWD 35 UTE

-3.65 TO+72.0 UTE UTS 2113 INLET 460HR 0.49 58 P 3 TWD 58 UTE

-3.65 TO+81.0 UTE UTS 2113 INLET 460HR 0.51 58 P 3 TWD 61 UTE

-3.65 TO+90.0 UTE UTS 2113 INLET 460HR 0.50 60 P 3 TWD 60 UTE

-3.65 TO+99.0 UTE UTS 2113 INLET 460HR 0.70 47 P 3 TWD 84 UTE

-3.65 TO+108.0 UTE UTS 2113 INLET 460HR 0.80 43 P 3 TWD 96 UTE

-3.65 TO+117.0 UTE UTS 2113 INLET 460HR 0.80 41 P 3 TWD 96 UTE

-3.65 TO+126.0 UTE UTS 2113 INLET 460HR

Framatome ANP Inc.

05/02/02 13:30:08 Customer Name: Oconee unit 1 Component: S/G B Page 107 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

==~=========
===

0.68 42 P 3 TWO 81 UTE

-3.65 TO+135.0 UTE UTS 2113 INLET 460HR 0.52 48 P 3 TWO 63 UTE

-3.65 TO+144.0 UTE UTS 2113 INLET 460HR 0.36 58 P 3 TWO 43 UTE

-3.65 TO+153.0 UTE UTS 2113 INLET 460HR 0.33 59 P 3 TWO 40 UTE

-3.65 TO+162.0 UTE UTS 2113 INLET 460HR 0.35 57 P 3 TWO 42 UTE

-3.65 TO+171.0 UTE UTS 2113 INLET 460HR 0.33 55 P 3 TWO 40 UTE

-3.65 TO+180.0 UTE UTS 2113 INLET 460HR 0.28 73 P 3 TWO 33 UTE

-3.65 TO+189.0 UTE UTS 2113 INLET 460HR 0.33 96 P 3 TWO 40 UTE

-3.65 TO+198.0 UTE UTS 2113 INLET 460HR 0.34 60 P 3 TWO 41 UTE

-3.65 TO+207.0 UTE UTS 2113 INLET 460HR 0.37 78 P 3 TWO 44 UTE

-3.65 TO+216.0 UTE UTS 2113 INLET 460HR 0.57 48 P 3 TWO 68 UTE

-3.65 TO+225.0 UTE UTS 2113 INLET 460HR 0.70 42 P 3 TWO 83 UTE

-3.65 TO+234.0 UTE UTS 2113 INLET 460HR 0.62 45 P 3 TWO 74 UTE

-3.65 TO+243.0 UTE UTS 2113 INLET 460HR 0.56 46 P 3 TWO 68 UTE

-3.65 TO+252.0 UTE UTS 2113 INLET 460HR 0.52 53 P 3 TWO 62 UTE

-3.65 TO+261. 0 UTE UTS 2113 INLET 460HR 0.45 61 P 3 TWO 54 UTE

-3.65 TO+270.0 UTE UTS 2113 INLET 460HR 0.27 79 P 3 TWO 33 UTE

-3.65 TO+279.0 UTE UTS 2113 INLET 460HR 0.21 110 P 3 TWO 25 UTE

-3.65 TO+288.0 UTE UTS 2113 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.65 TO+297.0 UTE UTS 2113 INLET 460HR 102 43 5.91 23 2

TEA UTE

-0.14 UTE UTE 2113 INLET 460HR 102 51 1.06 27 2

MAl UTE

-3.62 UTE UTS 2127 INLET 460HR 1.06 27 2

TWO 73 UTE

-3.62 UTE UTS 2127 INLET 460HR 102 54 1.22 26 2

SAl UTE

-3.53 UTE UTS 2112 INLET 460HR 1.25 24 2

TWO 65 UTE

-3.53 UTE UTS 2112 INLET 460HR 102 55 0.46 24 P 1 SCI UTE

-3.70 UTE UTS 2113 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.70 TO+319.5 UTE UTS 2113 INLET 460HR 0.20 40 P 3 TWO 23 UTE

-3.70 TO+328.5 UTE UTS 2113 INLET 460HR 0.16 56 P 3 TWO 19 UTE

-3.70 TO+337.5 UTE UTS 2113 INLET 460HR 0.21 38 P 3 TWO 24 UTE

-3.70 TO+346.5 UTE UTS 2113 INLET 460HR 0.20 45 P 3 TWO 24 UTE

-3.70 TO+355.5 UTE UTS 2113 INLET 460HR 0.10 82 P 3 TWO 12 UTE

-3.70 TO+4.5 UTE UTS 2113 INLET 460HR 0.10 90 P 3 TWO 11 UTE

-3.70 TO+13.5 UTE UTS 2113 INLET 460HR 0.20 38 P 3 TWO 23

  • UTE

-3.70 TO+22.5 UTE UTS 2113 INLET 460HR 0.19 54 P 3 TWO 23 UTE

-3.70 TO+31. 5 UTE UTS 2113 INLET 460HR 0.26 39 P 3 TWO 30 UTE

-3.70 TO+40.5 UTE UTS 2113 INLET 460HR 0.24 41 P 3 TWO 28 UTE

-3.70 TO+49.5 UTE UTS 2113 INLET 460HR 0.33 32 P 3 TWO 39

.uTE

-3.70 TO+58.5 UTE UTS 2113 INLET 460HR 0.41 29 P 3 TWO 48 UTE

-3.70 TO+67.5 UTE UTS 2113 INLET 460HR 0.47 25 P 3 TWO 55 UTE

-3.70 TO+76.5 UTE UTS 2113 INLET 460HR 0.54 24 P 3 TWO 63 UTE

-3.70 TO+85.5 UTE UTS 2113 INLET 460HR 0.56 26 P 3 TWO 65 UTE

-3.70 TO+94.5 UTE UTS 2113 INLET 460HR 0.59 25 P 3 TWO 68 UTE

-3.70 TO+I03.5 UTE UTS 2113 INLET 460HR 0.60 24 P 3 TWO 70 UTE

-3.70 TO+112.5 UTE UTS 2113 INLET 460HR 0.47 25 P 3 TWO 55 UTE

-3.70 TO+121. 5 UTE UTS 2113 INLET 460HR 0.23 25 P 3 TWO 27 UTE

-3.70 TO+130.5 UTE UTS 2113 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.70 TO+139.5 UTE UTS 2113 INLET 460HR 102 64 0.13 43 2

VOL 002

+1. 36 002 002 4049 OUTLET 460SI 102 68

1. 64 17 2

TEA UTE

-0.20 UTE UTE 2029 INLET 460HR 102 70 3.06 172 1 ONT LTE

+6.01 LTE LTE 4051 OUTLET 460S1 5.08 167 1 ONT LTE

+6.71 LTE LTE 4051 OUTLET 460SI 102 78 5.83 33 2

TEA UTE

-0.16 UTE UTE 2029 INLET 460HR 102 84 2.14 166 1 ONT LTS

-0.55 LTS LTS 4029 OUTLET 460SI 2.99 27 2

TEA UTE

-0.23 UTE UTE 2029 INLET 460HR 102 87

1. 52 18 2

TEA UTE

-0.17 UTE UTE 2030 INLET 460HR 102 88 4.43 31 2

TEA UTE

-0.12 UTE UTE 2029 INLET 460HR 102 90

1. 84 25 2

TEA UTE

-0.20 UTE UTE 2029 INLET 460HR 102 95 0.95 23 2

SAl UTE

-3.52 UTE UTS TR 2029 INLET 460HR 0.95 23 2

TWO 72 UTE

-3.52 UTE UTS TR 2029 INLET 460HR 102 99 0.81 29 2

SAl UTE

-3.57 UTE UTS TR 2029 INLET 460HR 0.81 29 2

TWO 96 UTE

-3.57 UTE UTS TR 2029 INLET 460HR 102 101 2.83 23 2

TEA UTE

-0.19 UTE UTE 2029 INLET 460HR 102 105 0.76 23 P 1 SCI UTE

-3.00 UTE UTS TR 2029 INLET 460HR 0.49 24 P 3 TWO 44 UTE

-3.00 TO+75.6 UTE UTS 2029 INLET 460HR 0.50 28 P 3 TWO 45 UTE

-3.00 TO+66.7 UTE UTS 2029 INLET 460HR 0.61 27 P 3 TWO 57 UTE

-3.00 TO+57.8 UTE UTS 2029 INLET 460HR 0.66 30 P 3 TWO 63 UTE

-3.00 TO+48.9 UTE UTS 2029 INLET 460HR 0.67 32 P 3 TWO 64 UTE

-3.00 TO+40.0 UTE UTS 2029 INLET 460HR 0.79 32 P 3 TWO 77 UTE

-3.00 TO+31. 1 UTE UTS 2029 INLET 460HR 0.58 37 P 3 TWO 54 UTE

-3.00 TO+22.2 UTE UTS 2029 INLET 460HR 0.36 30 P 3 TWO 32 UTE

-3.00 TO+13.3 UTE UTS 2029 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.00 TO+4.4 UTE UTS 2029 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.00 TO+84.4 UTE UTS 2029 INLET 460HR 102 107

1. 38 23 2

TEA UTE

-0.14 UTE UTE 2035 INLET 460HR 102 109 1.11 22 2

TEA UTE

-0.24 UTE UTE 2069 INLET 460HR 102 110 0.62 126 P 3 TWO 13 009

-0.56 009 009 WAR 4029 OUTLET 460S1

Framatome ANP Inc.

05/02/02 13:30:10 Customer Name: Oconee Unit 1 Component: S/G B Page 108 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS :- MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

102 114 3.14 24 2

TEA UTE

-0.13 UTE UTE 2070 INLET 460HR 102 115 3.64 24 2

TEA UTE

-0.20 UTE UTE 2069 INLET 460HR 0.27 37 P 3 TWO 6 009

+0.77 009 009 WAR 4029 OUTLET 460S1 102 116 2.07 24 2

TEA UTE

-0.17 UTE UTE 2070 INLET 460HR 102 117 0.75 26 2

TEA UTE

-0.26 UTE UTE 2069 INLET 460HR 0.47 48 P 3 TWO 13 006

-0.67 006 006 WAR 4029 OUTLET 460S1 102 118 0.38 13 P 3 TWO 10 009

+0.59 009 009 WAR 4029 OUTLET 460S1 102 119 2.98 354 3 ONT UTE

-11.43 UTE UTE 4087 OUTLET 460S1 7.58 177 1 ONT LTE

+11.02 LTE LTE 4029 OUTLET 460S1

11. 87 178 1 ONT 009

+0.84 009 009 4029 OUTLET 460S1 102 121 4.21 28 2

TEA UTE

-0.19 UTE UTE 2069 INLET 460HR 7.31 171 1 ONT LTE

+6.57 LTE LTE 4029 OUTLET 460S1 6.63 175 1 ONT LTE

+11. 77 LTE LTE 4029 OUTLET 460S1 6.54 169 1 ONT LTE

+7.36 LTE LTE 4029 OUTLET 460S1 4.29 345 1 ONT UTE

-8.67 UTE UTE 4029 OUTLET 460S1 6.94 169 1 ONT UTE

-12.31 UTE UTE 4029 OUTLET 460S1 102 123 4.97 191 1 ONT UTE

-9.29 UTE UTE 4087 OUTLET 460S1 3.44 173 1 ONT LTE

+7.03 LTE LTE 4029 OUTLET 460S1 103 3 0.31 77 2

VOL 004

+0.75 004 004 4099 OUTLET 460S1 103 4 0.15 106 2 VOL 004

+1.40 004 004 4099 OUTLET 460S1 103 6 3.22 28 2

TEA UTE

-0.21 UTE UTE 2112 INLET 460HR 103 8 0.39 109 P 3 TWO 11 011

+0.73 011 011 WAR 4099 OUTLET 460S1

1. 60 76 P 3 TWO 27 012

-0.63 012 012 WAR 4099 OUTLET 460S1 0.42 66 P 3 TWO 9 015

-0.73 015 015 WAR 4099 OUTLET 460S1 2.06 34 2

SAl UTE

-3.61 UTE UTS 2112 INLET 460HR 2.06 34 2

TWO 100 UTE

-3.61 UTE UTS 2112 INLET 460HR 103 9 0.36 91 P 3 TWO 10 010

-0.73 010 010 WAR 4099 OUTLET 460S1 0.43 96 P 3 TWO 12 011

-0.73 011 011 WAR 4099 OUTLET 460S1 0.51 III P 3 TWO 14 011

+0.75 011 011 WAR 4099 OUTLET 460S1 103 10 0.75 73 P 3 TWO 20 011

+0.69 011 011 WAR 4099 OUTLET 460S1 0.62 67 P 3 TWO 13 012

+0.73 012 012 WAR 4099 OUTLET 460S1 0.20 87 2

VOL 015

-0.92 015 015 4099 OUTLET 460S1

1. 04 65 P 3 TWO 19 015

+0.00 015 015 WAR 4099 OUTLET 460S1 3.78 29 2

TEA UTE

-0.17 UTE UTE 2112 INLET 460HR 103 11 0.60 97 P 3 TWO 12 007

+0.07 007 007 WAR 4099 OUTLET 460S1 2.13 29 2

TEA UTE

-0.22 UTE UTE 2113 INLET 460HR 103 14 0.64 100 P 3 TWO 13 009

-0.61 009 009 WAR 4099 OUTLET 460S1 0.51 72 P 3 TWO 11 009

+0.75 009 009 WAR 4099 OUTLET 460S1 0.08 88 2

VOL 014

+0.97 014 014 4099 OUTLET 460S1 103 15 0.33 99 2

VOL 014

+0.88 014 014 4097 OUTLET 460S1 103 16 0.20 72 2

VOL 014

+1. 00 014 014 4097 OUTLET 460S1 103 27 1.29 23 2

MAl UTE

-3.57 UTE UTS 2113 INLET 460HR 1.29 23 2

TWO 72 UTE

-3.57 UTE UTS 2113 INLET 460HR 103 31

1. 06 25 2

MAl UTE

-3.56 UTE UTS 2113 INLET 460HR

1. 06 25 2

TWO 80 UTE

-3.56 UTE UTS 2113 INLET 460HR 103 32 3.23 22 2

TEA UTE

-0.19 UTE UTE 2112 INLET 460HR 103 36 1.11 21 P 1 SCI UTE

-3.64 UTE UTS 2112 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.64 TO+120.0 UTE UTS 2112 INLET 460HR 0.12 42 P 3 TWO 6 UTE

-3.64 TO+128.9 UTE UTS 2112 INLET 460HR 0.32 10 P 3 TWO 17 UTE

-3.64 TO+137.8 UTE UTS 2112 INLET 460HR 0.60 15 P 3 TWO 31 UTE

-3.64 TO+146.7 UTE UTS 2112 INLET 460HR 0.70 16 P 3 TWO 37 UTE

-3.64 TO+155.6 UTE UTS 2112 INLET 460HR 0.80 14 P 3 TWO 42 UTE

-3.64 TO+164.4 UTE UTS 2112 INLET 460HR 0.69 12 P 3 TWO 36 UTE

-3.64 TO+173.3 UTE UTS 2112 INLET 460HR 0.54 15 P 3 TWO 28 UTE

-3.64 TO+182.2 UTE UTS 2112 INLET 460HR 0.33 18 P 3 TWO 18 UTE

-3.64 TO+191.1 UTE UTS 2112 INLET 460HR 0.34 14 P 3 TWO 18 UTE

-3.64 TO+200.0 UTE UTS 2112 INLET 460HR 0.32 29 P 3 TWO 17 UTE

-3.64 TO+208.9 UTE UTS 2112 INLET 460HR 0.24 30 P 3 TWO 12 UTE

-3.64 TO+217.8 UTE UTS 2112 INLET 460HR 0.23 24 P 3 TWO 12 UTE

-3.64 TO+226.7 UTE UTS 2112 INLET 460HR 0.32 24 P 3 TWO 17 UTE

-3.64 TO+235.6 UTE UTS 2112 INLET 460HR 0.24 21 P 3 TWO 12 UTE

-3.64 TO+244.4 UTE UTS 2112 INLET 460HR 0.15 26 P 3 TWO 8 UTE

-3.64 TO+253.3 UTE UTS 2112 INLET 460HR 0.11 106 P 3 TWO 6 UTE

-3.64 TO+262.2 UTE UTS 2112 INLET 460HR 0.14 68 P 3 TWO 7 UTE

-3.64 TO+271.1 UTE UTS 2112 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.64 TO+280.0 UTE UTS 2112 INLET 460HR 103 38 0.67 20 2

MAl UTE

-3.64 UTE UTS 2112 INLET 460HR 0.67 24 2

TWO 65 UTE

-3.64 UTE UTS 2112 INLET 460HR 0.80 22 2

TWO 59 UTE

-3.64 UTE UTS 2112 INLET 460HR 103 39 2.35 26 2

MAl UTE

-3.59 UTE UTS 2113 INLET 460HR 2.35 26 2

TWO 84 UTE

-3.59 UTE UTS 2113 INLET 460HR 103 60

1. 46 27 2

SAl UTE

-3.59 UTE UTS 2122 INLET 460HR

1. 46 27 2

TWO 78 UTE

-3.59 UTE UTS 2122 INLET 460HR 103 65 3.00 27 2

TEA UTE

-0.25 UTE UTE 2035 INLET 460HR 103 70 0.12 65 2

SAl 012

-9.96 012 012 4051 OUTLET 460S1

Framatome ANP Inc.

05/02/02 13:30:11 Customer Name: Oconee Unit 1 Component: S/G B Page 109 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS :- MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLT8 OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

0.12 65 2

TWO 60 012

-9.96 012 012 4051 OUTLET 460SI 103 73 2.59 22 2

TEA UTE

-0.20 UTE UTE 2035 INLET 460HR 103 75

1. 59 36 2

TEA UTE

-0.17 UTE UTE 2035 INLET 460HR 103 77 4.73 27 2

TEA UTE

-0.23 UTE UTE 2035 INLET 460HR 103 81 3.81 26 2

TEA UTE

-0.14 UTE UTE 2035 INLET 460HR 103 88 5.17 165 1 DNT LTE

+9.41 LTE LTE 4029 OUTLET 460SI 103 89 4.51 25 2

TEA UTE

-0.12 UTE UTE 2035 INLET 460HR 103 90 0.68 35 2

TEA UTE

-0.22 UTE UTE 2036 INLET 460HR 103 95 0.16 87 2

TWO 30 UT8

-1. 57 UTS UT8 4029 OUTLET 460SI 0.16 87 2

SAl UT8

-1. 57 UT8 UT8 4029 OUTLET 46081 103 104 0.11 73 2

VOL 010

+1. 07 010 010 4029 OUTLET 46081 103 109 0.63 164 P 3 TWO 14 010

+0.71 010 010 WAR 4029 OUTLET 460SI 103 117

1. 39 29 2

TEA UTE

-0.23 UTE UTE 2069 INLET 460HR 103 118 0.37 0

P 3 TWO 10 010

-0.86 010 010 WAR 4025 OUTLET 460SI 103 124 0.17 72 2

VOL 014

+1. 31 014 014 4029 OUTLET 46081 104 1

1. 39 27 2

TEA UTE

-0.27 UTE UTE 2111 INLET 460HR 104 3 0.25 75 2

VOL 004

+1.07 004 004 4099 OUTLET 460SI 104 4 3.87 23 2

TEA UTE

-0.17 UTE UTE 2111 INLET 460HR 104 7 2.07 29 2

TEA UTE

-0.13 UTE UTE 2110 INLET 460HR 104 8 0.40 103 P 3 TWO 11 008

+0.71 008 008 WAR 4099 OUTLET 46081 0.52 80 P 3 TWO 11 008

-0.69 008 008 WAR 4099 OUTLET 460SI 0.63 60 P 3 TWO 13 012

-0.66 012 012 WAR 4099 OUTLET 460SI 3.12 27 2

TEA UTE

-0.29 UTE UTE 2111 INLET 460HR 104 9 0.35 71 P 3 TWO 10 011

+0.73 011 011 WAR 4099 OUTLET 460SI

1. 02 69 P 3 TWO 19 011

-0.71 011 011 WAR 4099 OUTLET 460SI 0.40 135 P 3 TWO 12 012

+0.73 012 012 WAR 4099 OUTLET 460SI 0.49 71 P 3 TWO 10 012

-0.73 012 012 WAR 4099 OUTLET 460SI 104 10 0.62 37 P 3 TWO 13 011

+0.71 011 011 WAR 4099 OUTLET 46081 0.78 77 P 3 TWO 15 011

-0.69 011 011 WAR 4099 OUTLET 46081 104 16 0.50 87 P 3 TWO 11 014

+0.74 014 014 WAR 4099 OUTLET 460SI 104 22 2.21 34 2

TEA UTE

-0.19 UTE UTE 2112 INLET 460HR 104 25 0.93 34 2

MAl UTE

-3.57 UTE UT8 2113 INLET 460HR 0.93 34 2

TWO 88 UTE

-3.57 UTE UTS 2113 INLET 460HR 104 37 4.38 23 2

TEA UTE

-0.58 UTE UTE 2113 INLET 460HR 104 40 2.03 23-2 TEA UTE

-0.16 UTE UTE 2112 INLET 460HR 104 41 3.43 25 2

TEA UTE

-0.33 UTE UTE 2113 INLET 460HR 104 63 0.47 93 P 3 TWO 11 006

+0.23 006 006 WAR 4049 OUTLET 460SI 104 65 3.51 24 2

TEA UTE

-0.11 UTE UTE 2035 INLET 460HR 104 73 3.30 26 2

TEA UTE

-0.19 UTE UTE 2035 INLET 460HR 104 74 3.92 20 2

TEA UTE

-0.17 UTE UTE 2036 INLET 460HR 104 77 3.63 30 2

TEA UTE

-0.13 UTE UTE 2035 INLET 460HR 104 79 2.85 29 2

TEA UTE

-0.29 UTE UTE 2035 INLET 460HR 104 85 1.19 31 2

TEA UTE

-0.12 UTE UTE 2035 INLET 460HR 104 88 2.66 24 2

TEA UTE

-0.19 UTE UTE 2036 INLET 460HR 104 89 9.05 25 2

TEA UTE

-0.16 UTE UTE 2035 INLET 460HR 104 94 0.14 77 2

VOL UT8

-3.63 UTS UTS 4025 OUTLET 460SI 104 97 3.84 28 2

TEA UTE

-0.18 UTE UTE 2035 INLET 460HR 104 98 4.12 29 2

TEA UTE

-0.24 UTE UTE 2036 INLET 460HR 104 99 2.07 29 2

TEA UTE

-0.11 UTE UTE 2035 INLET 460HR 104 101 6.46 20 P 1 SCI UTE

-0.42 UTE UT8 CL 2035 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.42 TO+274.5 UTE UT8 2035 INLET 460HR 2.81 28 P 3 TWO 48 UTE

-0.42 TO+292.5 UTE UT8 2035 INLET 460HR 4.49 27 P 3 TWO 80 UTE

-0.42 TO+301.5 UTE UT8 2035 INLET 460HR 2.47 30 P 3 TWO 42 UTE

-0.42 TO+310.5 UTE UTS 2035 INLET 460HR 0.96 27 P 3 TWO 16 UTE

-0.42 TO+319.5 UTE UTS 2035 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.42 TO+328.5 UTE UTS 2035 INLET 460HR

1. 45 29 P 3 TWO 24 UTE

-0.42 TO+283.5 UTE UTS 2035 INLET 460HR 104 106 0.84 0

P 3 TWO 19 010

+0.67 010 010 WAR 4025 OUTLET 460SI 104 109 2.44 28 2

TEA UTE

-0.33 UTE UTE 2069 INLET 460HR 104 115 5.28 23 2

TEA UTE

-0.24 UTE UTE 2069 INLET 460HR 104 116 5.87 23 2

TEA UTE

-0.12 UTE UTE 2070 INLET 460HR 0.30 77 2

VOL 014

+0.86 014 014 4025 OUTLET 460SI 104 119 8.86 32 2

TEA UTE

-0.28 UTE UTE 2069 INLET 460HR 0.98 0

P 3 TWO 22 010

-0.56 010 010 WAR 4025 OUTLET 460SI 105 1 0.70 74 p 3 TWO 14 008

-0.27 008 008 WAR 4099 OUTLET 460SI 105 3 0.21 73 2

VOL 004

+0.80 004 004 4099 OUTLET 46081 2.81 26 2

TEA UTE

-0.12 UTE UTE 2110 INLET 460HR 105 6 0.69 57 P 3 TWO 19 007

-0.56 007 007 WAR 4099 OUTLET 460SI 9.33 174 1 ONT 009

+0.59 009 009 4099 OUTLET 460SI 105 7 0.44 110 P 3 TWO 9 008

+0.70 008 008 WAR 4099 OUTLET 46081 3.51 177 1 ONT 009

+0.55 009 009 4099 OUTLET 46081 105 11 0.11 72 2

VOL 014

+1. 07 014 014 4099 OUTLET 460SI 105 13 0.37 76 P 3 TWO 8 008

+0.63 008 008 WAR 4099 OUTLET 460SI 0.73 72 P 3 TWO 15 014

+0.73 014 014 WAR 4099 OUTLET 460SI 105 16

1. 54 84 P 3 TWO 26 014

+0.74 014 014 WAR 4099 OUTLET 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 105 17 105 29 105 37 105 60 105 61 105 62 105 63 105 64 105 65 105 67 105 68 105 69 105 70 105 73 105 74 105 79 105 81 105 88 105 98 105 100 105 102 105 103 105 105 105 106 105 108 105 111 105 113 105 114 105 115 3.20 0.62 0.00 0.09 0.13 0.28 0.37 0.40 0.21 0.15 0.00 4.73 0.35

1. 37
1. 92 3.24 1.24 3.68 3.88 8.09
1. 60
1. 60
1. 85 4.07 4.83
1. 37
1. 43 4.76 2.76 4.46 2.87 5.00
1. 80 1.80
1. 34 0.00 0.22 0.60 1.20 0.78 0.64 0.29 0.10 0.00 0.48 1.16 0.97 0.58 0.42 0.17 0.05 0.33
1. 74 3.81 3.87 5.37 0.33 0.73 0.57 0.72 3.33 4.65 3.23 0.00 2.06 3.00 2.36
1. 31 0.00 0.28 0.33 0.54 0.38 0.48 0.43 24 36 o

157 70 41 42 40 68 143 o

27 o

48 20 24 37 31 26 31 26 26 27 28 21 25 24 25 28 31 25 26 29 29 lS o

16 20 21 lS 20 23 170 o

25 20 20 19 22 17 296 59 19 22 26 3 o o o o 181 24 35 o

26 30 29 32 o o o o o o o 2

TEA UTE P 1 SCI UTE P 3 TWO 0 UTE P 3 TWO 22 UTE P 3 TWO 31 UTE P 3 TWO 6S UTE P 3 TWO 90 UTE P 3 TWO 98 UTE P 3 TWO 52 UTE P 3 TWO 36 UTE P 3 TWO 0 UTE 2

TEA UTE P 3 TWO 6 003 2

TEA UTE 2

TEA UTE 2

TEA UTE 2

TEA UTE 2

TEA UTE 2

TEA UTE 2

TEA UTE 2

SAl UTE 2

TWO 81 UTE 2

TEA UTE 2

TEA UTE 2

TEA UTE 2

TEA UTE 2

TEA UTE 2

TEA UTE 2

TEA UTE 2

TEA UTE 2

TEA UTE 2

TEA UTE 2

SAl UTE 2

TWO 95 UTE P 1 SCI UTE P 3 TWO 0 UTE P 3 TWO 11 UTE P 3 TWO 31 UTE P 3 TWO 62 UTE P 3 TWO 40 UTE P 3 TWO 33 UTE P 3 TWO 15 UTE P 3 TWO 5 UTE P 3 TWD 0 UTE P 3 TWD 30 UTE P 3 TWD 46 UTE P 3 TWD 42 UTE P 3 TWD 33 UTE P 3 TWD 2S UTE P 3 TWD 17 UTE P 3 TWO 0 UTE P 3 TWD 0 UTE P 1 SCI UTE 2

TEA UTE 2

TEA UTE 1

DNT LTE P 3 TWO 9 007 P 3 TWO 17 008 P 3 TWD 14 010 P 3 TWO 17 011 1

DNT UTS 2

TEA UTE P 1 SCI UTE P 3 TWD 0 UTE P 3 TWD 69 UTE P 3 TWD 100 UTE P 3 TWD 79 UTE P 3 TWD 44 UTE P 3 TWD 0 UTE P 3 TWD S 007 P 3 TWD 9 008 P 3 TWD 14 011 P 3 TWD 10 014 P 3 TWD 12 008 P 3 TWD 11 010

-0.24

-3.70

-3.70

-3.70

-3.70

-3.70

-3.70

-3.70

-3.70

-3.70

-3.70

-0.22

-0.19

-0.06

-0.20

-0.20

-0.21

-0.15

-0.23

-0.29

-3.55

-3.55

-0.19

-0.17

-0.24

-O.lS

-0.20

-0.22

-0.22

-0.23

-0.20

-0.19

-3.70

-3.70

-0.23

-0.23

-0.23

-0.23

-0.23

-0.23

-0.23

-0.23

-0.23

-0.23

-0.32

-0.32

-0.32

-0.32

-0.32

-0.32

-0.32

-0.32

-0.32

-0.27

-0.13

+12.49

-0.71

-0.74

-0.72

+0.60

+12.10

-0.23

-0.26

-0.26

-0.26

-0.26

-0.26

-0.26

-0.26

-0.73

-0.57

+0.62

+0.89

-0.55

-0.72 TO+198.0 TO+207.0 TO+216.0 TO+225.0 TO+234.0 TO+243.0 TO+252.0 TO+261.0 TO+270.0 TO+24S.9 TO+240.0 TO+231.1 TO+222.2 TO+213.3 TO+204.4 TO+195.6 TO+186.7 TO+177.S TO+144.0 TO+135.0 TO+126.0 TO+117.0 TO+10S.0 TO+99.0 TO+90.0 TO+153.0 TO+99.0 TO+108.0 TO+117.0 TO+126.0 TO+135.0 TO+144.0 05/02/02 13:30:12 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE 003 003 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE; UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE UTE UTE LTE LTE 007 007 008 008 010 010 011 011 UTS UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 007 007 OOS 008 011 011 014 014 008 008 010 010 WAR CL CL WAR WAR WAR WAR CL WAR WAR WAR WAR WAR WAR 2111 2111 2111 2111 2111 2111 2111 2111 2111 2111 2111 2111 4064 2110 2035 2036 2035 2036 2036 2035 2036 2036 2035 2036 2035 2036 2036 2035 2035 2035 2035 2036 2036 2036 2070 2070 2070 2070 2070 2070 2070 2070 2070 2070 2035 2035 2035 2035 2035 2035 2035 2035 2035 2069 2070 4025 4025 4025 4025 4025 4025 2069 2069 2069 2069 2069 2069 2069 2069 4025 4025 4025 4025 4025 4025 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET Page 110 of 155 PROBE 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460S1 460S1 460S1 460SI 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460S1 460SI 460SI 460S1 460SI

Framatome ANP Inc.

05/02/02 13:30:13 Customer Name: Oconee Unit 1 Component: S/G B Page 111 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -: MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

105 117 3.20 26 2

TEA UTE

-0.22 UTE UTE 2069 INLET 460HR 0.35 0

P 3 TWO 9 009

+0.64 009 009 WAR 4025 OUTLET 460S1 105 118 0.54 0

P 3 TWO 14 009

+0.68 009 009 WAR 4025 OUTLET 460SI 105 119 2.85 18 2

TEA UTE

-0.19 UTE UTE 2069 INLET 460HR 0.58 0

P 3 TWO 15 009

-0.67 009 009 WAR 4025 OUTLET 460S1 106 2 2.54 35 2

TEA UTE

-0.22 UTE UTE 2110 INLET 460HR 106 4 4.60 26 2

TEA UTE

-0.18 UTE UTE 2110 INLET 460HR 106 6 4.12 179 1 ONT 009

+0.58 009 009 4099 OUTLET 460SI 106 8 2.36 18 2

TEA UTE

-0.30 UTE UTE 2111 INLET 460HR 106 9 2.96 23 2

TEA UTE

-0.15 UTE UTE 2110 INLET 460HR 106 11 0.34 138 P 3 TWO 8 007

-0.70 007 007 WAR 4099 OUTLET 460SI 0.39 77 P 3 TWO 9 007

+0.67 007 007 WAR 4099 OUTLET 460S1 106 16

1. 79 23 2

TEA UTE

-0.12 UTE UTE 2110 INLET 460HR 106 19

1. 90 17 2

TEA UTE

-0.17 UTE UTE 2110 INLET 460HR 106 21 1.88 32 2

TEA UTE

-0.22 UTE UTE 2110 INLET 460HR 106 23 1.55 24 2

TEA UTE

-0.13 UTE UTE 2110 INLET 460HR 106 33 2.65 46 2

TEA UTE

-0.13 UTE UTE 2110 INLET 460HR 106 40 4.38 167 1 ONT LTS

-15.13 LTS LTS 4064 INLET 460SI

1. 91 169 1 ONT LTS

-11.17 LTS LTS 4064 INLET 460SI 106 42 3.37 24 2

TEA UTE

-0.30 UTE UTE 2111 INLET 460HR 106 45 8.67 36 2

TEA UTE

-0.07 UTE UTE 2110 INLET 460HR 106 51

1. 96 20 2

TEA UTE

-0.28 UTE UTE 2111 INLET 460HR 106 55 4.37 182 1 ONT UTE

-6.95 UTE UTE 4064 INLET 460SI 4.15 172 1 ONT UTE

-6.29 UTE UTE 4064 INLET 460SI 106 58 1.22 36 2

TEA UTE

-0.13 UTE UTE 2110 INLET 460HR 106 64 2.99 25 2

TEA UTE

-0.22 UTE UTE 2036 INLET 460HR 106 66 3.65 32 2

TEA UTE

-0.24 UTE UTE 2035 INLET 460HR 106 69

1. 42 27 2

TEA UTE

-0.18 UTE UTE 2035 INLET 460HR 106 70 4.34 23 2

TEA UTE

-0.21 UTE UTE 2036 INLET 460HR 106 73 2.33 30 2

TEA UTE

-0.15 UTE UTE 2035 INLET 460HR 106 74 1.12 40 2

TEA UTE

-0.29 UTE UTE 2036 INLET 460HR 106 76

1. 45 32 2

TEA UTE

-0.23 UTE UTE 2036 INLET 460HR 106 78 5.60 23 2

TEA UTE

-0.24 UTE UTE 2036 INLET 460HR 106 81 2.35 20 2

TEA UTE

-0.24 UTE UTE 2035 INLET 460HR 106 84

1. 42 20 2

TEA UTE

-0.29 UTE UTE 2036 INLET 460HR 106 85 1.23 24 P 1 MCI UTE

-4.22 UTE UTS TR 2035 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-4.22 TO+234.0 UTE UTS 2035 INLET 460HR 0.33 19 P 3 TWO 26 UTE

-4.22 TO+243.0 UTE UTS 2035 INLET 460HR 0.50 31 P 3 TWO 44 UTE

-4.22 TO+252.0 UTE UTS 2035 INLET 460HR 0.76 27 P 3 TWO 74 UTE

-4.22 TO+261. 0 UTE UTS 2035 INLET 460HR 0.64 26 P 3 TWO 60 UTE

-4.22 TO+270.0 UTE UTS 2035 INLET 460HR 0.42 21 P 3 TWO 36 UTE

-4.22 TO+279.0 UTE UTS 2035 INLET 460HR 0.37 20 P 3 TWO 30 UTE

-4.22 TO+288.0 UTE UTS 2035 INLET 460HR 0.26 12 P 3 TWO 19 UTE

-4.22 TO+297.0 UTE UTS 2035 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-4.22 TO+306.0 UTE UTS 2035 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-4.22 TO+333.0 UTE UTS CRACK2 2035 INLET 460HR 0.34 26 P 3 TWO 41 UTE

-4.22 TO+342.0 UTE UTS 2035 INLET 460HR 0.48 27 P 3 TWO 58 UTE

-4.22 TO+351. 0 UTE UTS 2035 INLET 460HR 0.66 26 P 3 TWO 76 UTE

-4.22 TO+O.O UTE UTS 2035 INLET 460HR 0.64 29 P 3 TWO 74 UTE

-4.22 TO+9.0 UTE UTS 2035 INLET 460HR 0.56 34 P 3 TWO 67 UTE

-4.22 TO+18.0 UTE UTS 2035 INLET 460HR 0.60 32 p 3 TWO 70 UTE

-4.22 TO+27.0 UTE UTS 2035 INLET 460HR 0.56 31 P 3 TWO 67 UTE

-4.22 TO+36.0 UTE UTS 2035 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-4.22 TO+45.0 UTE UTS 2035 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-4.22 TO+153.0 UTE UTS CRACK3 2035 INLET 460HR 0.05 145 P 3 TWO 5 UTE

-4.22 TO+162.0 UTE UTS 2035 INLET 460HR 0.14 52 P 3 TWO 12 UTE

-4.22 T0+171. 0 UTE UTS 2035 INLET 460HR 0.29 35 P 3 TWO 92 UTE

-4.22 TO+180.0 UTE UTS 2035 INLET 460HR 0.24 210 P 3 TWO 54 UTE

-4.22 TO+189.0 UTE UTS 2035 INLET 460HR 0.15 35 P 3 TWO 16 UTE

-4.22 TO+198.0 UTE UTS 2035 INLET 460HR 0.07 63 P 3 TWO 5 UTE

-4.22 TO+207.0 UTE UTS 2035 INLET 460HR 0.19 32 P 3 TWO 28 UTE

-4.22 TO+216.0 UTE UTS 2035 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-4.22 TO+225.0 UTE UTS 2035 INLET 460HR 106 88 1.17 29 2

TEA UTE

-0.29 UTE UTE 2036 INLET 460HR 106 91 5.57 26 2

TEA UTE

-0.20 UTE UTE 2035 INLET 460HR 106 92

1. 92 25 2

TEA UTE

-0.24 UTE UTE 2036 INLET 460HR 106 94 3.26 29 2

TEA UTE

-0.19 UTE UTE 2036 INLET 460HR 106 96 0.13 67 2

VOL 014

+1. 22 014 014 4025 OUTLET 460S1 2.99 19 2

TEA UTE

-0.15 UTE UTE 2036 INLET 460HR 106 99 3.14 26 2

TEA UTE

-0.13 UTE UTE 2035 INLET 460HR 106 100 3.06 22 2

TEA UTE

-0.16 UTE UTE 2036 INLET 460HR 106 102 0.27 0

P 3 TWO 7 008

-0.70 008 008 WAR 4025 OUTLET 460SI 0.27 0

P 3 TWO 7 009

+0.67 009 009 WAR 4025 OUTLET 460SI 106 103 0.61 0

P 3 TWD 15 010

+0.70 010 010 WAR 4025 OUTLET 46081 106 106

1. 86 24 2

TEA UTE

-0.10 UTE UTE 2070 INLET 460HR

Framatome ANP Inc.

05/02/02 13:30:15 Customer Name: Oconee Unit 1 Component: S/G B Page 112 of 155 ATTACHMENT #4 -

LI5T OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMI ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

106 109 3.04 170 1 ONT UTS

+12.19 UTS UTS 4025 OUTLET 460SI 106 113 3.24 25 2

TEA UTE

-0.20 UTE UTE 2069 INLET 460HR 2.45 179 1 ONT LTE

+11. 38 LTE LTE 4025 OUTLET 460SI 0.24 0

P 3 TWO 7 009

+0.71 009 009 WAR 4025 OUTLET 460SI 0.50 0

P 3 TWO 13 012

-0.64 012 012 WAR 4025 OUTLET 460SI 0.22 0

P 3 TWO 6 015

-0.75 015 015 WAR 4025 OUTLET 460SI 5.78 183 1 ONT UTE

-11. 65 UTE UTE 4025 OUTLET 460SI 106 114 3.39 18 2

TEA UTE

-0.14 UTE UTE 2070 INLET 460HR 6.21 175 1 ONT LTE

+11. 94 LTE LTE 4025 OUTLET 460SI 5.14 181 1 ONT UTE

-11.69 UTE UTE 4025 OUTLET 460SI 6.47 178 1 ONT UTE

-12.18 UTE UTE 4025 OUTLET 460SI 106 115 3.87 25 2

TEA UTE

-0.17 UTE UTE 2069 INLET 460HR 0.20 0

P 3 TWO 6 007

-0.61 007 007 WAR 4025 OUTLET 460SI 106 116 3.27 19 2

TEA UTE

-0.16 UTE UTE 2070 INLET 460HR 106 118 2.64 17 2

TEA UTE

-0.24 UTE UTE 2069 INLET 460HR 5.16 176 1 ONT LTS

-13.31 LTS LTS 4025 OUTLET 460SI 1.21 175 1 ONT LTS

-11.64 LTS LTS 4025 OUTLET 46051 0.15 64 2

VOL 014

+0.98 014 014 4025 OUTLET 460SI 6.05 180 1 ONT UTE

-11.10 UTE UTE 4025 OUTLET 460SI 106 119 6.16 177 1 ONT LTE

+11.77 LTE LTE 4025 OUTLET 460SI 9.67 173 1 ONT 010

-0.52 010 010 4025 OUTLET 460SI 0.11 64 2

VOL 014

+0.98 014 014 4025 OUTLET 460SI 6.15 180 1 ONT UTE

-11.81 UTE UTE 4025 OUTLET 460SI 107 2 0.37 101 2 VOL 012

+0.79 012 012 4099 OUTLET 460SI 107 3 0.37 70 P 3 TWO 8 008

-0.12 008 008 WAR 4099 OUTLET 460SI 107 4 14.25 176 1 ONT 009

+0.43 009 009 4099 OUTLET 460SI 107 13 2.26 22 2

TEA UTE

-0.20 UTE UTE 2111 INLET 460HR 107 27 0.45 0

P 3 TWO 10 004

+0.65 004 004 WAR 4064 INLET 46051 107 29 6.00 23 2

TEA UTE

-0.28 UTE UTE 2111 INLET 460HR 107 31 2.76 22 2

TEA UTE

-0.25 UTE UTE 2111 INLET 460HR 107 33 1.74 16 2

TEA UTE

-0.22 UTE UTE 2111 INLET 460HR 107 35

1. 56 11 2

TEA UTE

-0.19 UTE UTE 2111 INLET 460HR 107 36 0.80 18 P 1 5VI UTE

-1.14 UTE UTE TR 2110 INLET 460HR 0.80 18 P 1 TWO 51 UTE

-1.14 UTE UTE 2110 INLET 460HR 107 46 0.20 0

P 3 TWO 4 007

+0.07 007 007 WAR 4064 INLET 46051 107 63 3.01 27 2

TEA UTE

-0.23 UTE UTE 2036 INLET 460HR 107 64 2.06 29 2

TEA UTI;:

-0.27 UTE UTE 2035 INLET 460HR 107 66 4.09 27 2

TEA UTE

-0.29 UTE UTE 2035 INLET 460HR 107 67 4.16 28 2

TEA UTE

-0.18 UTE UTE 2036 INLET 460HR 107 75 0.69 59 2

TEA UTE

-0.24 UTE UTE 2036 INLET 460HR 107 78 4.71 27 2

TEA UTE

-0.18 UTE UTE 2035 INLET 460HR 107 79 2.50 23 2

TEA UTE

-0.21 UTE UTE 2036 INLET 460HR 107 81 0.20 97 2

VOL 007

+0.46 007 007 4025 OUTLET 46051 107 85

1. 04 189 1 ONT LT5

-9.38 LTS LTS 4025 OUTLET 460SI 107 87

1. 67 41 2

TEA UTE

-0.19 UTE UTE 2036 INLET 460HR 107 89 3.11 19 2

TEA UTE

-0.18 UTE UTE 2036 INLET 460HR 107 92

1. 43 22 2

TEA UTE

-0.31 UTE UTE 2035 INLET 460HR 0.08 86 2

VOL UT5

-5.19 UTE UTS 4025 OUTLET 460SI 107 95 2.91 20 2

TEA UTE

-0.21 UTE UTE 2036 INLET 460HR 107 96 2.02 19 2

TEA UTE

-0.24 UTE UTE 2035 INLET 460HR 107 104 2.03 25 2

TEA UTE

-0.17 UTE UTE 2035 INLET 460HR 0.25 0

P 3 TWO 7 008

-0.76 008 008 WAR 4025 OUTLET 46051 107 105 0.40 0

P 3 TWO 11 010

+0.76 010 010 WAR 4025 OUTLET 460SI 2.59 27 2

TEA UTE

-0.21 UTE UTE 2036 INLET 460HR 107 106 0.52 44 2

VOL 014

+0.81 014 014 4025 OUTLET 46051 107 107 0.20 0

P 3 TWO 6 010

+0.68 010 010 WAR 4025 OUTLET 460SI

1. 90 23 2

TEA UTE

-0.20 UTE UTE 2036 INLET 460HR 107 109 2.94 26 2

TEA UTE

-0.14 UTE UTE 2070 INLET 460HR 0.28 0

P 3 TWO 7 008

-0.67 008 008 WAR 4025 OUTLET 460SI 0.59 0

P 3 TWO 15 009

+0.36 009 009 WAR 4025 OUTLET 46051 107 110 4.33 28 2

TEA UTE

-0.15 UTE UTE 2069 INLET 460HR 0.89 0

P 3 TWO 20 008

-0.63 008 008 WAR 4025 OUTLET 46051 107 111 2.19 22 2

TEA UTE

-0.16 UTE UTE 2070 INLET 460HR 2.99 176 1 ONT LTE

+11.91 LTE LTE 4025 OUTLET 460SI 2.85 179 1 ONT UTE

-11. 98 UTE UTE 4025 OUTLET 460SI 107 112 2.54 23 2

TEA UTE

-0.20 UTE UTE 2069 INLET 460HR 5.20 181 1 ONT LTE

+11. 68 LTE LTE 4025 OUTLET 460SI 0.45 0

P 3 TWO 12 008

-0.69 008 008 WAR 4025 OUTLET 460SI 0.54 0

P 3 TWO 14 010

-0.74 010 010 WAR 4025 OUTLET 46051 0.50 0

p 3 TWO 13 011

+0.63 011 011 WAR 4025 OUTLET 460SI 0.39 60 2

VOL 012

-0.64 012 012 4025 OUTLET 460SI 6.49 187 1 ONT UTS

+12.65 UTS UTS 4025 OUTLET 460SI 107 116 1.22 20 2

TEA UTE

-0.20 UTE UTE 2069 INLET 460HR 6.25 354 1 ONT UTE

-11.75 UTE UTE 4025 OUTLET 46051 107 120 2.49 11 2

TEA UTE

-0.18 UTE UTE 2070 INLET 460HR

Framatome ANP Inc.

05/02/02 13:30:16 Customer Name: Oconee unit 1 Component: S/G B Page 113 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS "7 MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

108 2 4.68 5

1 DNT LTE

+2.67 LTE LTE 4099 OUTLET 460S1 2.39 177 1 DNT LTS

+0.22 LTS LTS 4099 OUTLET 460S1

1. 48 180 1 DNT LTS

+1.33 LTS LTS 4099 OUTLET 460S1 108 3 3.36 19 2

TEA UTE

-0.23 UTE UTE 2111 INLET 460HR 108 4 0.70 31 2

TEA UTE

-0.22 UTE UTE 2110 INLET 460HR 108 5 1.15 33 2

TEA UTE

-0.20 UTE UTE 2110 INLET 460HR 108 7 2.66 24 2

TEA UTE

-0.24 UTE UTE 2111 INLET 460HR 108 8 0.82 48 2

TEA UTE

-0.21 UTE UTE 2110 INLET 460HR 108 9 0.23 101 2 VOL 014

+0.97 014 014 4099 OUTLET 460S1 2.94 20 2

TEA UTE

-0.26 UTE UTE 2111 INLET 460HR 108 11 5.51 29 2

TEA UTE

-0.20 UTE UTE 2110 INLET 460HR 108 13 1.28 18 2

TEA UTE

-0.27 UTE UTE 2111 INLET 460HR 108 15 2.80 24 2

TEA UTE

-0.23 UTE UTE 2111 INLET 460HR 108 16 0.70 31 2

TEA UTE

-0.24 UTE UTE 2110 INLET 460HR 108 17 4.25 34 2

TEA UTE

-0.23 UTE UTE 2111 INLET 460HR 108 18

1. 94 20 2

TEA UTE

-0.18 UTE UTE 2110 INLET 460HR 108 19 3.11 16 2

TEA UTE

-0.16 UTE UTE 2111 INLET 460HR 108 20

1. 99 26 2

TEA UTE

-0.13 UTE UTE 2110 INLET 460HR 108 26 0.59 15 P 1 SVI UTE

-1. 35 UTE UTE TR 2110 INLET 460HR 0.59 15 P 1 TWD 41 UTE

-1.35 UTE UTE 2110 INLET 460HR 108 28 1.56 28 2

TEA UTE

-0.18 UTE UTE 2110 INLET 460HR 108 31 4.19 21 2

TEA UTE

-0.22 UTE UTE 2111 INLET 460HR 108 33 0.26 135 2 VOL 007

+0.43 007 007 4064 INLET 460S1

1. 46 16 2

TEA UTE

-0.27 UTE UTE 2111 INLET 460HR 108 34 3.88 26 2

TEA UTE

-0.12 UTE UTE 2110 INLET 460HR 108 36 1.33 22 2

TEA UTE

-0.15 UTE UTE 2110 INLET 460HR 108 44 3.97 32 2

TEA UTE

-0.11 UTE UTE 2110 INLET 460HR 108 47 0.32 0

P 3 TWD 6 007

+0.34 007 007 WAR 4064 INLET 460S1 6.78 23 2

TEA UTE

-0.30 UTE UTE 2111 INLET 460HR 108 48

1. 69 29 2

TEA UTE

-0.14 UTE UTE 2110 INLET 460HR 108 58 3.61 21 2

TEA UTE

-0.28 UTE UTE 2111 INLET 460HR 108 59

1. 93 27 2

TEA UTE

-0.11 UTE UTE 2110 INLET 460HR 108 63 0.76 27 2

TEA UTE

-0.20 UTE UTE 2039 INLET 460HR 108 64 3.42 24 2

TEA UTE

-0.22 UTE UTE 2040 INLET 460HR 108 65 3.70 28 2

TEA UTE

-0.22 UTE UTE 2039 INLET 460HR lOB 66 0.24 74 2

SAl 015

+19.65 015 015 4022 OUTLET 460S1 0.24 74 2

TWD 36 015

+19.65 015 015 4022 OUTLET 460S1 0.35 71 2

SAl 015

+20.75 015 015 4022 OUTLET 460S1 0.35 71 2

TWD 41 015

+20.75 015 015 4022 OUTLET 460S1 4.67 24 2

TEA UTE

-0.15 UTE UTE 2040 INLET 460HR 108 67 0.53 15 2

TEA UTE

-0.20 UTE UTE 2039 INLET 460HR 108 68 2.29 24 2

TEA UTE

-0.13 UTE UTE 2040 INLET 460HR 108 69 0.53 19 2

TEA UTE

-0.23 UTE UTE 2039 INLET 460HR 108 70 3.44 22 2

TEA UTE

-O.lB UTE UTE 2040 INLET 460HR lOB 74 4.08 30 2

TEA UTE

-0.14 UTE UTE 2040 INLET 460HR 108 77 0.32 41 2

TEA UTE

-0.17 UTE UTE 2039 INLET 460HR 108 B2

1. 92 21 2

TEA UTE

-0.20 UTE UTE 2040 INLET 460HR 108 87 0.49 15 2

TEA UTE

-0.22 UTE UTE 2039 INLET 460HR 108 88 2.75 26 2

TEA UTE

-0.17 UTE UTE 2040 INLET 460HR 108 90 2.79 24 2

TEA UTE

-0.14 UTE UTE 2040 INLET 460HR 108 91 1.04 23 2

TEA UTE

-0.20 UTE UTE 2039 INLET 460HR 108 93 0.38 19 2

TEA UTE

-0.19 UTE UTE 2039 INLET 460HR 108 94 2.48 22 2

TEA UTE

-0.20 UTE UTE 2040 INLET 460HR 108 107 2.70 176 1 DNT 012

+14.46 012 012 4025 OUTLET 460S1 108 109 0.25 0

P 3 TWD 7 008

-0.60 008 008 WAR 4025 OUTLET 460S1 0.19 0

P 3 TWD 5 011

-0.05 011 011 WAR 4025 OUTLET 460S1 108 110 2.84 19 2

TEA UTE

-0.11 UTE UTE 2070 INLET 460HR 108 115 2.60 18 2

TEA UTE

-0.25 UTE UTE 2069 INLET 460HR 5.74 181 1 DNT LTE

+11. 30 LTE LTE 4025 OUTLET 460S1 5.63 173 1 DNT UTE

-11. 68 UTE UTE 4025 OUTLET 460S1 108 118 0.68 22 P 1 SCI UTE

-3.47 UTE UTS 2069 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-3.47 TO+18.0 UTE UTS 2069 INLET 460HR 0.28 29 P 3 TWD 30 UTE

-3.47 TO+27.0 UTE UTS 2069 INLET 460HR 0.46 26 P 3 TWD 50 UTE

-3.47 To+36.0 UTE UTS 2069 INLET 460HR 0.60 22 P 3 TWD 66 UTE

-3.47 TO+45.0 UTE UTS 2069 INLET 460HR 0.58 22 P 3 TWD 64 UTE

-3.47 TO+54.0 UTE UTS 2069 INLET 460HR 0.56 20 P 3 TWD 62 UTE

-3.47 TO+63.0 UTE UTS 2069 INLET 460HR 0.50 19 p 3 TWD 55 UTE

-3.47 TO+72.0 UTE UTS 2069 INLET 460HR 0.34 21 P 3 TWD 37 UTE

-3.47 TO+81. 0 UTE UTS 2069 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-3.47 TO+90.0 UTE UTS 2069 INLET 460HR 108 119 1.57 19 2

TEA UTE

-0.16 UTE UTE 2070 INLET 460HR 109 2 0.26 75 2

VOL 012

+0.91 012 012 4101 OUTLET 460SI 109 3 6.13 174 1 DNT 009

+0.17 009 009 4101 OUTLET 46081 3.11 27 2

TEA UTE

-0.21 UTE UTE 2110 INLET 460HR 109 8 3.44 30 2

TEA UTE

-0.14 UTE UTE 2110 INLET 460HR

Framatome ANP Inc.

05/02/02 13:30:17 Customer Name: Oconee Unit 1 Component: S/G B Page 114 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS..., MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

109 9 0.90 76 P 3 TWD 14 009

-0.74 009 009 WAR 4101 OUTLET 460SI 109 14 4.81 30 2

TEA UTE

-0.14 UTE UTE 2110 INLET 460HR 109 16 0.40 29 P 1 SVI UTE

-3.67 UTE UT8 TR 2110 INLET 460HR 0.40 29 P 1 TWD 96 UTE

-3.67 UTE UT8 2110 INLET 460HR 109 23 3.32 17 2

TEA UTE

-0.18 UTE UTE 2111 INLET 460HR 109 27 2.59 21 2

TEA UTE

-0.25 UTE UTE 2111 INLET 460HR 109 28 1.27 28 2

TEA UTE

-0.22 UTE UTE 2110 INLET 460HR 109 30 2.98 26 2

TEA UTE

-0.12 UTE UTE 2110 INLET 460HR 109 32 3.38 177 1 DNT LTE

+8.71 LTE LTE 4064 INLET 46081 109 33 4.20 27 2

TEA UTE

-0.20 UTE UTE 2111 INLET 460HR 109 34

1. 50 22 2

TEA UTE

-0.21 UTE UTE 2110 INLET 460HR 109 36

1. 89 28 2

TEA UTE

-0.12 UTE UTE 2110 INLET 460HR 109 39 2.38 21 2

TEA UTE

-0.24 UTE UTE 2111 INLET 460HR 109 42 2.41 22 2

TEA UTE

-0.20 UTE UT8 2110 INLET 460HR 109 44 8.98 184 1 DNT UT8

+13.41 UT8 UTE 4113 OUTLET 520SI 2.65 90 1

VOL UT8

+13.58 UTE UTS 4113 OUTLET 520SI

1. 43 81 1

VOL UT8

+16.44 UTE UT8 4113 OUTLET 52081 0.83 82 1

VOL UT8

+18.93 UTE UT8 4113 OUTLET 52081 109 48 3.07 22 2

TEA UTE

-0.18 UTE UTE 2110 INLET 460HR 109 49 5.19 23 2

TEA UTE

-0.29 UTE UTE 2111 INLET 460HR 109 50 0.50 8

2 ONT 015

+12.23 015 015 4064 INLET 460SI 109 59 3.25 27 2

TEA UTE

-0.08 UTE UTE 2110 INLET 460HR 109 60

1. 41 178 1 ONT UT8

+11.82 UT8 UT8 4022 OUTLET 46081 2.07 163 1 DNT UT8

+12.82 UTS UT8 4022 OUTLET 46081

1. 60 11 1

DNT UT8

+13.82 UT8 UT8 4022 OUTLET 46081 0.86 23 2

TEA UTE

-0.22 UTE UTE 2039 INLET 460HR 109 62

1. 66 187 1 ONT 015

+17.04 015 015 4022 OUTLET 46081 109 63

1. 06 29 2

TEA UTE

-0.25 UTE UTE 2039 INLET 460HR 109 67 0.60 31 2

TEA UTE

-0.24 UTE UTE 2039 INLET 460HR 109 78 0.67 21 2

TEA UTE

-0.20 UTE UTE 2039 INLET 460HR 109 84 0.87 23 2

TEA UTE

-0.21 UTE UTE 2039 INLET 460HR 109 85 1.10 55 2

TEA UTE

-0.20 UTE UTE 2040 INLET 460HR 109 90 0.81 33 2

TEA UTE

-0.17 UTE UTE 2039 INLET 460HR 109 93 2.32 23 2

TEA UTE

-0.26 UTE UTE 2040 INLET 460HR 109 95 3.04 27 2

TEA UTE

-0.15 UTE UTE 2040 INLET 460HR 109 98 0.76 32 2

TEA UTE

-0.16 UTE UTE 2039 INLET 460HR 109 99 4.61 23 2

TEA UTE

-0.13 UTE UTE 2040 INLET 460HR 109 102 1.20 14 2

TEA UTE

-0.14 UTE UTE 2039 INLET 460HR 109 103 0.58 124 P 3 TWD 13 010

+0.01 010 010 WAR 4022 OUTLET 46081 109 104 1.19 101 P 3 TWD 24 010

+0.66 010 010 WAR 4022 OUTLET 46081 109 106 3.34 22 2

TEA UTE

-0.14 UTE UTE 2069 INLET 460HR 109 108 0.65 114 P 3 TWO 15 008

-0.63 008 008 WAR 4022 OUTLET 46081 0.67 109 P 3 TWD 15 010

+0.70 010 010 WAR 4022 OUTLET 46081 109 109

1. 84 25 2

TEA UTE

-0.19 UTE UTE 2070 INLET 460HR 0.26 54 P 3 TWD 6 007

-0.73 007 007 WAR 4022 OUTLET 460SI 0.47 108 P 3 TWD 11 008

-0.67 008 008 WAR 4022 OUTLET 46081 0.23 87 P 3 TWD 6 010

+0.77 010 010 4022 OUTLET 46081 1.10 102 P 3 TWD 22 011

+0.63 011 011 WAR 4022 OUTLET 4608I 0.66 74 P 3 TWD 15 011

-0.71 011 011 WAR 4022 OUTLET 46081 0.35 58 P 3 TWD 8 012

-0.82 012 012 WAR 4022 OUTLET 4608I 0.99 78 P 3 TWD 21 013

+0.65 013 013 WAR 4022 OUTLET 460SI 109 111 4.39 27 2

TEA UTE

-0.15 UTE UTE 2069 INLET 460HR 5.20 182 1 DNT LTE

+12.14 LTE LTE 4022 OUTLET 46081 0.50 100 P 3 TWO 12 008

-0.77 008 008 WAR 4022 OUTLET 46081 0.74 98 P 3 TWD 16 009

+0.58 009 009 WAR 4022 OUTLET 46081 0.80 66 P 3 TWD 17 010

-0.71 010 010 WAR 4022 OUTLET 460SI 0.34 67 P 3 TWD 8 011

+0.66 011 011 WAR 4022 OUTLET 460SI 109 112

1. 56 25 2

8Al UTE

-3.47 UTE UT8 2070 INLET 460HR

1. 56 25 2

TWD 74 UTE

-3.47 UTE UT8 2070 INLET 460HR 4.09 182 1 ONT 010

-0.75 010 010 4022 OUTLET 46081 0.63 168 P 3 TWO 15 010

-0.70 010 010 WAR 4022 OUTLET 46081 0.67 84 P 3 TWO 15 008

+0.62 008 008 WAR 4022 OUTLET 460SI 0.75 0

P 3 TWD 18 010

-0.59 010 010 WAR 4022 OUTLET 46081 109 113 0.41 96 P 3 TWD 10 008

-0.68 008 008 WAR 4022 OUTLET 460S1 0.62 0

P 3 TWD 15 009

+0.75 009 009 WAR 4022 OUTLET 46081 4.52 167 1 ONT 010

-0.58 010 010 4022 OUTLET 46081 0.85 100 P 3 TWO 18 013

+0.67 013 013 WAR 4022 OUTLET 46081 109 114 2.31 27 2

TEA UTE

-0.18 UTE UTE 2070 INLET 460HR 7.06 177 1 DNT 010

-0.50 010 010 4022 OUTLET 46081 109 115 1.20 20 2

TEA UTE

-0.16 UTE UTE 2069 INLET 460HR 8.53 177 1 DNT 010

-0.64 010 010 4022 OUTLET 460S1 109 117 2.95 23 2

TEA UTE

-0.18 UTE UTE 2069 INLET 460HR 110 1 3.82 13 2

TEA UTE

-0.13 UTE UTE 2103 INLET 460HR 0.15 59 2

VOL LT8

+3.28 LT8 LT8 4051 OUTLET 46081 110 2

1. 66 31 2

TWD 95 UTE

-3.53 UTE UT8 2102 INLET 460HR

Framatome ANP Inc.

Customer Name: Oconee unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION 1103 110 4 1106 1107 110 8 110 10 110 15 110 16 110 25 110 27 110 32 110 43 110 45 110 48 110 49 110 56 110 57 110 59 110 61 110 64 110 67 110 70 110 71 110 76 110 77 110 78 110 79 110 92 110 93 110 94 110 95 110 97 110 100 110 104 110 107 110 108 110 109 110 112 110 113 110 114 110 115 110 116 III 4 III 5 111 6 111 8 11111 111 15 III 18 III 24 111 28 III 30 III 31 111 33 III 34

1. 66 3.08 12.58 0.11 5.01 0.37 2.95 2.79 0.14 2.40 2.05 0.73 2.48 5.06 0.66 0.66 4.49 3.22
1. 59 0.19 6.55 6.31 4.30
1. 48
1. 58
1. 35
1. 35
1. 35 1.28 3.65 2.05 5.53 4.64 2.44 2.15 0.98 0.98 2.87
1. 95 2.71 0.25 0.13 0.37 0.30 5.86 0.29 0.48 4.06 6.89 1.92 7.43 6.66 7.99 2.58 2.15 5.13 6.22 10.83 0.53 10.70 10.79 8.82 6.22 4.60 3.29 5.77 2.28 4.37 0.46 0.46 10.83 2.25 2.44 2.55 2.25 31 2

SAl 167 1 DNT 172 1 DNT 84 2

VOL 22 2

TEA 44 27 30 P 3 TWO 9 2

TEA 2

TEA 76 P

25 2

22 2

23 2

27 2

23 2

22 2

22 2

24 2

22 2

30 2

49 P

26 2

25 2

20 2

24 2

21 2

31 2

24 2

24 2

25 2

21 2

25 2

180 1 25 2

2 2

2 2

2 2

2 23 25 24 24 26 30 28 3 TWO 3 TEA TEA VOL TEA TEA MAl TWO 60 TEA TEA TEA 3 TWD 5 TEA TEA TEA TEA TEA TEA MAl TWO 62 TEA TEA TEA DNT TEA TEA TEA MAl TWD 62 TEA TEA TEA TWD 6 3

9 8

TWO TWO TWO DNT 96 P3 149 P 3 54 P 3 138 P 3 184 1 141 P 3 TWD 4 P 3 TWO 7 1

DNT 106 183 DNT TEA DNT DNT DNT TEA TEA TEA TEA DNT 3 TWD 12 ONT ONT DNT TEA TEA TEA TEA TEA TEA 181 1 24 2

182 1 178 1 179 1 25 2

27 2

24 2

18 2

178 1 64 P

178 1 181 1 173 1 27 2

21 2

15 2

19 2

20 2

28 2

23 P 4 TWO 74 P 4 SVI 23 185 1 ONT 20 2

TEA 13 2

TEA 14 2

TEA 21 2

TEA UTE 010 009 013 UTE 009 UTE UTE 008 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 007 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 006 UTE UTE UTE UTE UTE UTE UTE UTE 009 009 009 010 UTE 012 011 LTE UTS UTE 010 010 010 UTE UTE UTE UTE LTE 009 UTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 006 UTE UTE UTE UTE

-3.53

+4.74

+0.25

+1.22

-0.29

-0.71

-0.17

-0.32

+0.78

-0.20

-0.35

-1. 29

-0.18

-0.21

-3.62

-3.62

-0.14

-0.44

-0.13

+0.74

-0.29

-0.17

-0.13

-0.14

-0.16

-0.12

-2.96

-2.96

-0.17

-0.16

-0.11

+16.21

-0.16

-0.22

-0.12

-3.33

-3.33

-0.17

-0.24

-0.13

-0.21

-0.60

+0.57

-0.74

-11.43

-0.68

+0.72

+11.95

+12.57

-0.19

-0.66

-0.64

-0.63

-0.18

-0.26

-0.19

-0.13

+11. 36

-0.46

-11.16

+11. 23

. -12.20

-0.18

-0.19

-0.16

-0.18

-0.22

-0.15

-1.80

-1. 80

+12.10

-0.18

-0.11

-0.13

-0.15 05/02/02 13:30:19 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTS TR 010 010 009 009 013 013 UTE UTE 009 009 WAR UTE UTE UTE UTE 008 008 WAR UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UTE UTE UTE UTE UTE 007 007 WAR UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS TR UTE UTS UTE UTE UTE UTE UTE UTE 006 006 UTE UTE UTE UTE UTE UTE UTE UTS TR UTE UTS UTE UTE UTE UTE UTE UTE 009 009 WAR 009 009 WAR 009 009 WAR 010 010 WAR UTE UTE 012 012 WAR 011 011 WAR LTE LTE UTE 015 UTE UTE 010 010 010 010 010 010 UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE 009 009 WAR UTE UTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE CS 006 006 UTE UTE UTE UTE UTE UTE UTE UTE 2102 4051 4051 4051 2107 4051 2106 2107 4051 2106 2107 2106 2106 2107 2106 2106 2106 2107 2106 4061 2107 2106 2042 2041 2042 2041 2042 2042 2041 2042 2041 4014 2041 2042 2041 2042 2042 2042 2041 2041 4014 4014 4014 4014 4026 4026 4026 4026 4014 2065 4014 4014 4014 2066 2065 2102 2103 4051 4051 4051 4051 4051 2102 2102 2103 2103 2102 2102 2102 2102 4040 2102 2103 2103 2102 INLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 115 of 155 PROBE 460HR 460SI 460SI 460SI 460HR 460SI 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460S1 460SI 460SI 460S1 460HR 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460S1 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR

Framatome ANP Inc.

05/02/02 13:30:20 Customer Name: Oconee Unit 1 Component: S/G B Page 116 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

111 35 3.54 16 2

TEA UTE

-0.15 UTE UTE 2103 INLET 460HR 111 36 3.19 28 2

TEA UTE

-0.12 UTE UTE 2102 INLET 460HR 111 41 4.47 14 2

TEA UTE

-0.17 UTE UTE 2103 INLET 460HR 111 42

1. 65 21 2

TEA UTE

-0.19 UTE UTE 2102 INLET 460HR 111 44 3.08 27 2

TEA UTE

-0.24 UTE UTE 2102 INLET 460HR 111 48

1. 67 32 2

TEA UTE

-0.12 UTE UTE 2102 INLET 460HR 111 57 2.97 20 2

TEA UTE

-0.10 UTE UTE 2103 INLET 460HR 0.34 46 P 3 TWO 9 008

-0.77 008 008 WAR 4061 OUTLET 460SI 111 58 3.40 23 2

TEA UTE

-0.12 UTE UTE 2102 INLET 460HR 111 59 2.86 183 1 ONT UTE

-1.78 UTE UTE 4014 INLET 460SI 1.61 186 1 ONT UTE

-3.26 UTE UTE 4014 INLET 460SI 2.48 191 1 ONT UTE

-4.01 UTE UTE 4014 INLET 460SI 111 62

1. 43 25 2

TEA UTE

-0.20 UTE UTE 2042 INLET 460HR 111 63

1. 09 24 2

SAl UTE

-3.64 UTE UTS 2041 INLET 460HR

1. 09 24 2

TWO 75 UTE

-3.64 UTE UTS 2041 INLET 460HR 111 72 2.81 19 2

TEA UTE

-0.17 UTE UTE 2042 INLET 460HR 111 74 0.10 109 2 SAl 015

+9.63 015 015 4014 INLET 460SI 0.10 109 2 TWO 18 015

+9.63 015 015 4014 INLET 460SI 0.10 134 2 SAl 015

+10.60 015 015 4014 INLET 460SI 0.10 134 2 TWO 9 015

+10.60 015 015 4014 INLET 460SI 0.08 151 2 SAl 015

+11. 78 015 015 4014 INLET 460SI 0.08 151 2 TWO 4 015

+11.78 015 015 4014 INLET 460SI 111 77 2.22 26 2

TEA UTE

-0.13 UTE UTE 2041 INLET 460HR 111 78 4.55 23 2

TEA UTE

-0.24 UTE UTE 2042 INLET 460HR 111 79 2.00 22 2

TEA UTE

-0.19 UTE UTE 2041 INLET 460HR 111 86 3.45 25 2

TEA UTE

-0.24 UTE UTE 2042 INLET 460HR 111 87 3.25 26 2

TEA UTE

-0.14 UTE UTE 2041 INLET 460HR 111 94 2.52 22 2

TEA UTE

-0.15 UTE UTE 2041 INLET 460HR 111 95 2.27 14 2

TEA UTE

-0.17 UTE UTE 2042 INLET 460HR 111 96 2.60 31 2

TEA UTE

-0.14 UTE UTE 2041 INLET 460HR 111 97

1. 59 27 2

TEA UTE

-0.17 UTE UTE 2042 INLET 460HR 111 101 0.31 74 P 3 TWO 8 014

+0.71 014 014 WAR 4014 INLET 460SI 111 104 0.40 47 P 3 TWO 10 008

-0.61 008 008 WAR 4014 INLET 460SI 2.04 30 2

TEA UTE

-0.15 UTE UTE 2042 INLET 460HR 111 105

1. 98 25 2

TEA UTE

-0.14 UTE UTE 2065 INLET 460HR 111 106 0.23 29 P 3 TWO 6 010

-0.57 010 010 WAR 4014 INLET 460SI 111 108

1. 05 24 2

TEA UTE

-0.19 UTE UTE 2066 INLET 460HR 111 109 6.89 173 1 ONT LTE

+11.56 LTE LTE 4087 OUTLET 460SI 4.83 32 2

TEA UTE

-0.11 UTE UTE 2065 INLET 460HR 7.19 182 1 ONT UTE

-12.47 UTE UTE 4014 INLET 460SI 0.10 169 P 3 TWO 3 015

-0.75 015 015 WAR 4014 INLET 460SI 0.37 115 P 3 TWO 9 012

-0.66 012 012 WAR 4014 INLET 460SI 0.51 41 P 3 TWO 12 010

-0.72 010 010 WAR 4014 INLET 460SI 0.33 142 P 3 TWO 8 008

-0.65 008 008 WAR 4014 INLET 460SI 111 110 9.75 183 1 ONT LTE

+11.73 LTE LTE 4109 OUTLET 460SI 0.76 19 2

MAl UTE

-3.35 UTE UTS TR 2066 INLET 460HR 0.61 18 2

TWO 59 UTE

-3.35 UTE UTS 2066 INLET 460HR 0.51 12 2

TWO 39 UTE

-3.35 UTE UTS 2066 INLET 460HR 8.37 187 1 ONT UTE

-12.40 UTE UTE 4014 INLET 460SI 0.65 131 P 3 TWO 15 013

+0.71 013 013 WAR 4014 INLET 460SI 0.39 151 P 3 TWO 10 012

-0.77 012 012 WAR 4014 INLET 460SI 0.70 54 P 3 TWO 16 010

-0.69 010 010 WAR 4014 INLET 460SI 111 111 6.28 175 1 ONT 010

-0.72 010 010 4014 INLET 460SI 111 112 2.13 18 2

TEA UTE

-0.14 UTE UTE 2065 INLET 460HR 7.25 170 1 ONT 010

-0.70 010 010 4014 INLET 460SI 111 113 5.16 31 2

TEA UTE

-0.17 UTE UTE 2066 INLET 460HR 0.47 92 P 3 TWO 11 013

+0.66 013 013 WAR 4014 INLET 460SI 6.05 177 1 ONT 010

-0.66 010 010 4014 INLET 460S1 0.61 120 P 3 TWO 14 006

-0.76 006 006 WAR 4014 INLET 460S1 111 114 2.82 32 2

TEA UTE

-0.16 UTE UTE 2065 INLET 460HR 111 115 0.18 97 2

VOL 014

+1.14 014 014 4014 INLET 460SI 112 3 5.05 18 2

TEA UTE

-0.13 UTE UTE 2103 INLET 460HR 112 4 0.18 141 2 VOL 008

+0.32 008 008 4051 OUTLET 460SI 0.14 100 P 3 TWO 3 008

+0.70 008 008 WAR 4051 OUTLET 460SI 0.13 85 2

VOL 014

+0.95 014 014 4051 OUTLET 460SI 1.35 30 2

TWO 91 UTE

-3.54 UTE UTS 2102 INLET 460HR 1.35 30 2

SAl UTE

-3.54 UTE UTS TR 2102 INLET 460HR 112 7

1. 78 12 2

TEA UTE

-0.20 UTE UTE 2103 INLET 460HR 8.35 178 1 ONT LTE

+11. 38 LTE LTE 4051 OUTLET 460SI 7.63 184 1 ONT UTE

-11.10 UTE UTE 4051 OUTLET 460SI 112 8 0.23 27 P 3 TWO 6 009

+0.50 009 009 WAR 4051 OUTLET 460SI 112 9 3.73 14 2

TEA UTE

-0.19 UTE UTE 2103 INLET 460HR 112 12 2.18 22 2

TEA UTE

-0.16 UTE UTE 2102 INLET 460HR 1.17 20 P 4 SVI UTE

-1.24 UTE UTE TR 2102 INLET 460HR 1.17 20 P 4 TWO 65 UTE

-1.24 UTE UTE 2102 INLET 460HR

Framatome ANP Inc.

05/02/02 13:30:21 Customer Name: Oconee Unit 1 Component: S/G B Page 117 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -. MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

112 13 2.45 16 2

TEA UTE

-0.12 UTE UTE 2103 INLET 460HR 112 14 2.79 24 2

TEA UTE

-0.21 UTE UTE 2102 INLET 460HR 112 16 2.39 165 1 ONT 007

+9.88 007 007 4051 OUTLET 460S1 112 20 0.91 34 P 4 TWO 97 UTE

-1.14 UTE UTE 2102 INLET 460HR 0.91 34 P 4 SVI UTE

-1.14 UTE UTE TR 2102 INLET 460HR 112 22 2.41 30 2

TEA UTE

-0.18 UTE UTE 2102 INLET 460HR 112 28 6.75 26 2

TEA UTE

-0.14 UTE UTE 2102 INLET 460HR 112 29 4.16 22 2

TEA UTE

-0.10 UTE UTE 2103 INLET 460HR 112 30 2.97 27 2

TEA UTE

-0.14 UTE UTE 2102 INLET 460HR 112 38 2.87 28 2

TEA UTE

-0.17 UTE UTE 2102 INLET 460HR 112 41 7.12 18 2

TEA UTE

-0.14 UTE UTE 2103 INLET 460HR 112 43 4.48 17 2

TEA UTE

-0.17 UTE UTE 2103 INLET 460HR 112 45 2.74 24 2

TEA UTE

-0.12 UTE UTE 2103 INLET 460HR 112 46 12.97 170 1 ONT 006

+6.85 006 006 4061 OUTLET 460S1 112 52

1. 42 32 2

TWO 100 UTE

-3.61 UTE UTS 2102 INLET 460HR

1. 42 32 2

SAl UTE

-3.61 UTE UTS TR 2102 INLET 460HR 112 56 0.21 351 P 3 TWO 0 UTE

-0.12 TO+327.7 UTE UTE 2102 INLET 460HR 0.34 21 P 3 TWO 16 UTE

-0.12 TO+318.5 UTE UTE 2102 INLET 460HR 1.03 17 P 3 TWO 28 UTE

-0.12 TO+309.2 UTE UTE 2102 INLET 460HR 1.25 13 P 3 TWO 31 UTE

-0.12 TO+300.0 UTE UTE 2102 INLET 460HR 1.04 14 P 3 TWO 28 UTE

-0.12 TO+290.8 UTE UTE 2102 INLET 460HR 0.36 24 P 3 TWO 16 UTE

-0.12 TO+281.5 UTE UTE 2102 INLET 460HR 0.27 357 P 3 TWO 0 UTE

-0.12 TO+272.3 UTE UTE 2102 INLET 460HR

1. 91 20 P 1 SCI UTE

-0.12 UTE UTE CL 2102 INLET 460HR 112 67 1.35 28 2

SAl UTE

-3.29 UTE UTS 2041 INLET 460HR 1.35 28 2

TWO 89 UTE

-3.29 UTE UTS 2041 INLET 460HR 112 73 0.60 20 P 1 MCI UTE

-3.78 UTE UTS 2041 INLET 460HR 0.24 25 P 3 TWO 0 UTE

-3.78 TO+40.5 UTE UTS 2041 INLET 460HR 0.27 18 P 3 TWO 55 UTE

-3.78 TO+31. 5 UTE UTS 2041 INLET 460HR 0.31 24 P 3 TWO 59 UTE

-3.78 TO+22.5 UTE UTS 2041 INLET 460HR 0.37 22 P 3 TWO 64 UTE

-3.78 TO+13.5 UTE UTS 2041 INLET 460HR 0.27 21 P 3 TWO 55 UTE

-3.78 TO+4.5 UTE UTS 2041 INLET 460HR 0.35 16 P 3 TWO 0 UTE

-3.82 TO+I08.0 UTE UTS 2041 INLET 460HR 0.29 15 P 3 TWO 57 UTE

-3.82 TO+99.0 UTE UTS 2041 INLET 460HR 0.26 20 P 3 TWO 54 UTE

-3.82 TO+90.0 UTE UTS 2041 INLET 460HR 0.34 22 P 3 TWO 61 UTE

-3.82 TO+81. 0 UTE UTS 2041 INLET 460HR 0.27 13 P 3 TWO 55 UTE

-3.82 T.O+72.0 UTE UTS 2041 INLET 460HR 0.26 1

P 3 TWO 0 UTE

-3.82 TO+63.0 UTE UTS 2041 INLET 460HR 0.14 21 P 3 TWO 0 UTE

-3.78 TO+355.5 UTE UTS 2041 INLET 460HR 112 75 0.82 19 2

TWO 58 UTE

-3.58 UTE UTS 2041 INLET 460HR 0.82 19 2

SAl UTE

-3.58 UTE UTS 2041 INLET 460HR 112 76 2.97 20 2

TEA UTE

-0.24 UTE UTE 2042 INLET 460HR 112 77 3.13 23 2

TEA UTE

-0.15 UTE UTE 2041 INLET 460HR 112 82

1. 42 19 2

TEA UTE

-0.19 UTE UTE 2042 INLET 460HR 112 89

1. 83 37 2

TEA UTE

-0.17 UTE UTE 2041 INLET 460HR 112 95

1. 71 24 2

SAl UTE

-3.16 UTE UTS 2041 INLET 460HR

1. 71 24 2

TWO 75 UTE

-3.16 UTE UTS 2041 INLET 460HR 112 97 4.88 23 2

TEA UTE

-0.12 UTE UTE 2041 INLET 460HR 112 98 3.03 22 2

TEA UTE

-0.18 UTE UTE 2042 INLET 460HR 112 103 1.10 0

P 3 TWO 14 009

+0.66 009 009 WAR 4014 INLET 460SI 112 104 2.35 23 2

TEA UTE

-0.18 UTE UTE 2042 INLET 460HR 112 106 2.53 23 2

TEA UTE

-0.16 UTE UTE 2062 INLET 460HR 112 107 2.24 23 2

TEA UTE

-0.26 UTE UTE 2061 INLET 460HR 0.36 142 P 3 TWO 9 011

+0.58 011 011 WAR 4014 INLET 460S1 0.30 147 P 3 TWO 7 008

-0.70 008 008 WAR 4014 INLET 460S1 0.35 149 P 3 TWO 9 007

-0.62 007 007 WAR 4014 INLET 460S1 112 108 3.48 28 2

TEA UTE

-0.20 UTE UTE 2062 INLET 460HR 0.58 115 P 3 TWO 14 013

+0.63 013 013 WAR 4014 INLET 460S1 0.57 145 P 3 TWO 13 008

-0.68 008 008 WAR 4014 INLET 460S1 0.48 58 P 3 TWO 12 007

-0.60 007 007 WAR 4014 INLET 460S1 112 109 0.43 125 P 3 TWO 11 013

-0.63 013 013 WAR 4014 INLET 460S1 0.69 52 P 3 TWO 16 010

-0.70 010 010 WAR 4014 INLET 460SI 0.43 110 P 3 TWO 11 008

-0.70 008 008 WAR 4014 INLET 460SI 0.14 105 P 3 TWO 3 007

-0.62 007 007 WAR 4014 INLET 460S1 112 110 5.14 166 1 ONT LTE

+10.82 LTE LTE 4087 OUTLET 460S1

1. 81 15 2

TEA UTE

-0.19 UTE UTE 2062 INLET 460HR 0.56 95 P 3 TWO 13 010

-0.79 010 010 WAR 4014 INLET 460SI 0.71 112 P 3 TWO 16 009

+0.66 009 009 WAR 4014 INLET 460SI 112 112 6.73 169 1 ONT LTE

+11.25 LTE LTE 4087 OUTLET 460S1

1. 46 28 2

TEA UTE

-0.28 UTE UTE 2061 INLET 460HR 7.87 169 1 ONT UTE

-11. 71 UTE UTE 4015 INLET 460S1 1.80 41 2

TEA UTE

-0.21 UTE UTE 4015 INLET 460S1 0.14 67 2

VOL 014

+1.17 014 014 4015 INLET 460S1 8.26 170 1 ONT 010

-0.70 010 010 4015 INLET 460SI 112 113 8.69 171 1 ONT LTE

+11. 23 LTE LTE 4087 OUTLET 460SI

Framatome ANP Inc.

05/02/02 13:30:23 Customer Name: Oconee Unit 1 Component: 8/G B Page 118 of 155 ATTACHMENT #4 -

LI8T OF IMPERFECTIONS -, MRPC/PLU8 POINT QUERY: QueryMI ROW TUBE VOLT8 OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

1.81 18 2

TEA UTE

-0.22 UTE UTE 2062 INLET 460HR 9.96 161 1 DNT UTE

-12.10 UTE UTE 4015 INLET 46081

11. 55 168 1 ONT 010

-0.66 010 010 4015 INLET 46081 0.39 64 P 3 TWO 6 009

+0.64 009 009 WAR 4015 INLET 46081 112 114 12.26 169 1 ONT 010

-0.61 010 010 4015 INLET 46081 112 116 9.12 168 1 DNT 010

-0.63 010 010 4015 INLET 460SI 0.14 110 2 VOL 004

+1. 23 004 004 4015 INLET 46081 113 3 0.11 70 2

VOL 012

+1.17 012 012 4051 OUTLET 46081 0.11 60 2

VOL 013

+0.99 013 013 4051 OUTLET 46081 113 4 0.21 118 P 3 TWO 5 008

+0.62 008 008 WAR 4051 OUTLET 460SI 0.37 89 P 3 TWO 9 009

-0.76 009 009 WAR 4051 OUTLET 460SI 0.27 108 P 3 TWO 6 011

+0.79 011 011

.WAR 4051 OUTLET 46081 0.37 23 P 3 TWO 9 011

-0.70 011 011 WAR 4051 OUTLET 46081 3.30 23 2

TEA UTE

-0.18 UTE UTE 2102 INLET 460HR 113 11 0.51 16 P 1 VOL UTE

-1. 89 UTE UTE 2102 INLET 460HR 113 15

1. 87 27 2

TEA UTE

-0.17 UTE UTE 2102 INLET 460HR 113 16

1. 31 9

2 TEA UTE

-0.10 UTE UTE 2103 INLET 460HR 0.13 72 2

VOL 014

+1.22 014 014 4051 OUTLET 46081 113 18 3.68 24 2

TEA UTE

-0.15 UTE UTE 2103 INLET 460HR 113 19 2.09 28 2

TEA UTE

-0.22 UTE UTE 2102 INLET 460HR 113 23 4.39 20 2

TEA UTE

-0.17 UTE UTE 2103 INLET 460HR 113 25 5.91 23 2

TEA UTE

-0.13 UTE UTE 2103 INLET 460HR 113 27

1. 92 21 2

8AI UTE

-3.56 UTE UT8 2103 INLET 460HR

1. 92 21 2

TWO 62 UTE

-3.56 UTE UT8 2103 INLET 460HR 113 33 4.23 15 2

TEA UTE

-0.19 UTE UTE 2103 INLET 460HR 113 35 3.23 17 2

TEA UTE

-0.16 UTE UTE 2103 INLET 460HR 113 37 3.35 20 2

TEA UTE

-0.17 UTE UTE 2103 INLET 460HR 113 39 1.50 15 2

TEA UTE

-0.15 UTE UTE 2103 INLET 460HR 113 49 0.92 12 2

TEA UTE

-0.16 UTE UTE 2103 INLET 460HR 113 55 4.51 19 2

TEA UTE

-0.15 UTE UTE 2103 INLET 460HR 113 56 1.86 16 2

TEA UTE

-0.11 UTE UTE 2102 INLET 460HR 113 59 10.87 51 2

PVN 013

-10.09 TO+4.13 013 013 4087 OUTLET 46081 7.25 53 2

PVN 014

-9.86 TO+4.37 014 014 4087 OUTLET 46081 2.23 25 2

TEA UTE

-0.18 UTE UTE 2041 INLET 460HR 113 60 3.01 25 2

TEA UTE

-0.16 UTE UTE 2042 INLET 460HR 113 63 0.54 33 2

8AI UTE

-3.33 UTE UT8 2041 INLET 460HR 0.54 33 2

TWO 99 UTE

-3.33 UTE UT8 2041 INLET 460HR 113 67 0.52 24 2

MAl UTE

-3.49 UTE UTS 2041 INLET 460HR 0.52 24 2

TWO 75 UTE

-3.49 UTE UTS 2041 INLET 460HR 113 68 2.96 34 2

TEA UTE

-0.22 UTE UTE 2042 INLET 460HR 113 73 0.35 89 P 3 TWO 6 007

-0.32 007 007 WAR 4023 INLET 46081 1.15 25 2

8AI UTE

-3.58 UTE UT8 2041 INLET 460HR 1.16 25 2

TWO 78 UTE

-3.58 UTE UT8 2041 INLET 460HR 113 83 2.66 21 2

TEA UTE

-0.15 UTE UTE 2041 INLET 460HR 113 104 0.35 79 2

VOL 014

+1.19 014 014 4023 INLET 46081 0.27 73 2

VOL 014

+0.78 014 014 4023 INLET 46081 113 109 0.57 99 P 3 TWO 9 010

-0.63 010 010 WAR 4023 INLET 46081 0.32 91 P 3 TWO 5 009

+0.66 009 009 WAR 4023 INLET 460SI 0.40 105 P 3 TWO 8 008

-0.61 008 008 WAR 4023 INLET 46081 0.49 69 P 3 TWO 8 008

+0.54 008 008 WAR 4023 INLET 46081 9.30 179 1 ONT LTE

+10.61 LTE LTE 4023 INLET 46081 7.61 180 1 ONT LTE

+11.48 LTE LTE 4023 INLET 46081 113 111

11. 21 180 1 ONT UTE

-7.68 UTE UTE 4023 INLET 46081 7.03 185 1 ONT UTE

-11. 04 UTE UTE 4023 INLET 46081 5.03 183 1 DNT UTE

-11.72 UTE UTE 4023 INLET 460SI

11. 36 176 1 ONT 010

-0.54 010 010 4023 INLET 46081 8.37 184 1 DNT LTE

+10.83 LTE LTE 4023 INLET 46081 7.03 3

1 DNT LTE

+4.32 LTE LTE 4023 INLET 46081 113 113 9.34 182 1 ONT UTE

-12.20 UTE UTE 4023 INLET 46081 13.06 178 1 ONT 010

-0.48 010 010 4023 INLET 46081 8.82 182 1 ONT LTE

+11. 06 LTE LTE 4023 INLET 460SI 8.40 182 1 ONT LTE

+11.83 LTE LTE 4023 INLET 46081 113 115 0.10 78 2

VOL 004

+0.74 TO+l.55 004 004 4015 INLET 46081 113 116 5.38 31 2

TEA UTE

-0.18 UTE UTE 2062 INLET 460HR 0.11 116 2 VOL 004

+1. 70 005 004 4035 INLET 46081 114 2 7.36 178 1 DNT LTE

+11.70 LTE LTE 4051 OUTLET 46081 0.15 41 2

VOL 010

+1. 32 010 010 4051 OUTLET 460S1 10.43 181 1 ONT UTE

-11. 54 UTE UTE 4051 OUTLET 46081

1. 51 27 2

MAl UTE

-3.61 UTE UT8 2101 INLET 460HR

1. 51 27 2

TWO 76 UTE

-3.61 UTE UT8 2101 INLET 460HR 114 5 0.19 78 2

VOL 013

+1. 04 013 013 4051 OUTLET 46081 114 7 2.25 21 2

TEA UTE

-0.09 UTE UTE 2101 INLET 460HR 114 8 3.70 21 2

TEA UTE

-0.12 UTE UTE 2100 INLET 460HR 114 10 3.53 182 1 DNT UTE

-5.36 UTE UTE 4051 OUTLET 46081 114 12 0.49 16 2

VOL UTE

-1.21 UTE UTE 2100 INLET 460HR

Framatome ANP Inc.

05/02/02 13:30:24 Customer Name: Oconee Unit 1 Component: S/G B Page 119 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -, MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

114 13 2.48 15 2

TEA UTE

-0.12 UTE UTE 2101 INLET 460HR 114 15 2.04 24 2

TEA UTE

-0.10 UTE UTE 2101 INLET 460HR 114 17

1. 68 22 2

TEA UTE

-0.17 UTE UTE 2101 INLET 460HR 114 20 3.77 30 2

TEA UTE

-0.21 UTE UTE 2100 INLET 460HR 114 21 0.85 31 2

SAl UTE

-3.54 UTE UTS 2101 INLET 460HR 0.85 31 2

TWO 92 UTE

-3.54 UTE UTS 2101 INLET 460HR 114 23 2.50 32 2

TEA UTE

-0.12 UTE UTE 2103 INLET 460HR 114 25 2.73 32 2

TEA UTE

-0.10 UTE UTE 2103 INLET 460HR 114 26 0.51 44 2

TWO 92 UTE

-3.60 UTE UTS 2102 INLET 460HR 0.51 44 2

SAl UTE

-3.60 UTE UTS TR 2102 INLET 460HR 114 27

1. 48 19 2

TEA UTE

-0.14 UTE UTE 2103 INLET 460HR 114 28 3.25 28 2

TEA UTE

-0.22 UTE UTE 2102 INLET 460HR 6.22 6

1 ONT 009

+15.31 009 009 4040 INLET 460SI 114 33 1.00 19 2

TEA UTE

-0.17 UTE UTE 2103 INLET 460HR 114 34 2.61 24 2

TEA UTE

-0.16 UTE UTE 2102 INLET 460HR 114 35 2.61 23 2

TEA UTE

-0.12 UTE UTE 2103 INLET 460HR 114 41

1. 61 15 2

TEA UTE

-0.15 UTE UTE 2103 INLET 460HR 0.35 46 2

VOL 001

+0.73 001 001 4061 OUTLET 460SI 114 42

1. 53 26 2

TEA UTE

-0.20 UTE UTE 2102 INLET 460HR 114 45 0.57 20 2

MAl UTE

-3.50 UTE UTS 2103 INLET 460HR 0.57 20 2

TWO 58 UTE

-3.50 UTE UTS 2103 INLET 460HR 114 49 4.22 16 2

TEA UTE

-0.14 UTE UTE 2103 INLET 460HR 114 53

1. 86 18 2

SAl UTE

-3.64 UTE UTS 2103 INLET 460HR

1. 86 18 2

TWO 50 UTE

-3.64 UTE UTS 2103 INLET 460HR 114 55 5.75 16 2

TEA UTE

-0.13 UTE UTE 2103 INLET 460HR 114 68 2.77 22 2

TEA UTE

-0.21 UTE UTE 2041 INLET 460HR 114 69 0.77 19 2

VOL UTE

-1. 07 UTE UTE TR 2042 INLET 460HR 0.68 22 2

VOL UTE

-1.27 UTE UTE TR 2042 INLET 460HR 114 70 0.61 28 P 1 MCI UTE

-3.64 UTE UTS 2041 INLET 460HR 0.15 334 p 3 TWO 0 UTE

-3.65 TO+184.5 UTE UTS 2041 INLET 460HR 0.23 10 p 3 TWO 36 UTE

-3.65 TO+175.5 UTE UTS 2041 INLET 460HR 0.43 22 P 3 TWO 49 UTE

-3.65 TO+166.5 UTE UTS 2041 INLET 460HR 0.37 27 P 3 TWO 45 UTE

-3.65 TO+157.5 UTE UTS 2041 INLET 460HR 0.39 34 P 3 TWO 47 UTE

-3.65 TO+148.5 UTE UTS 2041 INLET 460HR 0.29 28 P 3 TWO 40 UTE

-3.64 TO+139.5 UTE UTS 2041 INLET 460HR 0.16 21 p 3 TWO 30 UTE

-3.64 TO+130.5 UTE UTS 2041 INLET 460HR 0.39 37 P 3 TWO 47 UTE

-3.64 TO+121. 5 UTE UTS 2041 INLET 460HR 0.47 37 P 3 TWO 51 UTE

-3.64 TO+112.5 UTE UTS 2041 INLET 460HR 0.45 35 P 3 TWO 50 UTE

-3.64 TO+103.5 UTE UTS 2041 INLET 460HR 0.43 32 P 3 TWD 49 UTE

-3.64 TO+94.5 UTE UTS 2041 INLET 460HR 0.40 28 P 3 TWD 48 UTE

-3.64 TO+85.5 UTE UTS 2041 INLET 460HR 0.29 34 P 3 TWO 40 UTE

-3.64 TO+76.5 UTE UTS 2041 INLET 460HR 0.26 51 P 3 TWO 38 UTE

-3.64 TO+67.5 UTE UTS 2041 INLET 460HR 0.35 29 P 3 TWD 44 UTE

-3.64 TO+58.5 UTE UTS 2041 INLET 460HR 0.45 24 P 3 TWD 51 UTE

-3.64 TO+49.5 UTE UTS 2041 INLET 460HR 0.69 22 P 3 TWD 62 UTE

-3.64 TO+40.5 UTE UTS 2041 INLET 460HR 0.75 22 P 3 TWD 65 UTE

-3.64 TO+31. 5 UTE UTS 2041 INLET 460HR 0.55 33 P 3 TWO 56 UTE

-3.64 TO+22.5 UTE UTS 2041 INLET 460HR 0.41 40 P 3 TWO 48 UTE

-3.64 TO+13.5 UTE UTS 2041 INLET 460HR 0.31 40 P 3 TWD 42 UTE

-3.64 TO+4.5 UTE UTS 2041 INLET 460HR 0.32 35 P 3 TWD 42 UTE

-3.65 TO+355.5 UTE UTS 2041 INLET 460HR 0.23 37 P 3 TWD 36 UTE

-3.65 TO+346.5 UTE UTS 2041 INLET 460HR 0.12 29 P 3 TWD 0 UTE

-3.65 TO+337.5 UTE UTS 2041 INLET 460HR 114 71

1. 67 21 2

TEA UTE

-0.21 UTE UTE 2042 INLET 460HR 0.76 15 2

VOL UTE

-1. 31 UTE UTE TR 2042 INLET 460HR 114 72 0.48 21 2

SAl UTE

-3.63 UTE UTS 2041 INLET 460HR 0.48 21 2

TWO 64 UTE

-3.63 UTE UTS 2041 INLET 460HR 114 75 2.79 20 2

TEA UTE

-0.26 UTE UTE 2042 INLET 460HR 114 76 4.39 20 2

TEA UTE

-0.18 UTE UTE 2041 INLET 460HR 114 83

l. 99 18 2

TEA UTE

-0.27 UTE UTE 2042 INLET 460HR 114 84 0.50 22 2

MAl UTE

-3.67 UTE UTS 2041 INLET 460HR 0.50 22 2

TWO 68 UTE

-3.67 UTE UTS 2041 INLET 460HR 114 87 0.58 27 P 1 SCI UTE

-3.57 UTE UTS TR 2042 INLET 460HR 0.14 26 P 3 TWO 0 UTE

-3.57 TO+293.3 UTE UTS 2042 INLET 460HR 0.04 13 P 3 TWD 25 UTE

-3.57 TO+284.4 UTE UTS 2042 INLET 460HR 0.24 18 P 3 TWD 60 UTE

-3.57 TO+275.6 UTE UTS 2042 INLET 460HR 0.36 25 P 3 TWD 74 UTE

-3.57 TO+240.0 UTE UTS 2042 INLET 460HR 0.31 23 P 3 TWO 69 UTE

-3.57 TO+231.1 UTE UTS 2042 INLET 460HR 0.09 48

'p 3 TWO 38 UTE

-3.57 TO+222.2 UTE UTS 2042 INLET 460HR 0.10 358 p 3 TWO 0 UTE

-3.57 TO+213.3 UTE UTS 2042 INLET 460HR 0.37 22 P 3 TWO 75 UTE

-3.57 TO+248.9 UTE UTS 2042 INLET 460HR 0.31 22 P 3 TWD 69 UTE

-3.57 TO+257.8 UTE UTS 2042 INLET 460HR 0.40 20 P 3 TWD 78 UTE

-3.57 TO+266.7 UTE UTS 2042 INLET 460HR 114 90 0.81 22 2

MAl UTE

-3.68 UTE UTS 2041 INLET 460HR 0.81 22 2

TWD 68 UTE

-3.68 UTE UTS 2041 INLET 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION 114 91 114 92 114 93 114 95 114 96 114 97 114 103 114 104 114 108 114 112 114 113 114 115 1152 1153 115 5 115 6 115 7 115 8 115 9 115 10 115 11 115 13 115 14 115 17 115 21 115 22 115 29 115 30 115 39 115 54 115 55 115 57 115 63 115 68 115 69 115 70 115 73 115 74 115 75 115 77 115 78 115 80 115 82 115 84 115 94 115 95 115 98 115 101

1. 70 0.87 0.87 3.00 2.56 0.58 3.07 0.59 0.13 0.19 2.02 9.95 8.67 8.24 4.98 7.69 4.76 2.51
11. 55 0.20 0.09 0.14
1. 05 0.10 0.24 2.71 3.40 4.54 6.51 0.45 6.62 5.67 4.27 7.57 4.47 4.31 2.54 0.57 0.57 2.87 2.87 3.92
1. 75
1. 75 2.42 2.42 3.24 5.98 7.35 7.66 1.15 7.23 0.19
1. 85 1.14 1.14
1. 71 13.06 2.09
1. 83 3.32 2.41 2.39 2.66 2.05 2.40 3.33 2.88
1. 68
1. 59 2.57 4.64 5.50 3.35 3.14 23 2

TEA 23 2

SAl 23 2

TWD 71 27 2

TEA 20 2

TEA 144 P 3 TWD 9 17 2

TEA 52 P 3 TWD 9 69 2

VOL 87 2

VOL 20 2

TEA 185 1 DNT 182 1 DNT 356 1 DNT 182 1 DNT 184 1 DNT 181 1 DNT 27 2

TEA 180 1 DNT 66 2

VOL 82 2

VOL 68 2

VOL 25 2

TEA 90 2

VOL 72 2

VOL 26 2

TEA 24 2

TEA 27 2

TEA 185 1 DNT 102 P 3 TWD 11 186 1 DNT 176 1 DNT 186 1 DNT 184 1 DNT 27 2

TEA 28 2

TEA 22 2

TEA 29 2

SAl 29 2

TWD 84 30 2

MAl 30 2

TWD 93 29 2

TEA 38 2

MAl 38 2

TWD 98 29 2

MAl 29 2

TWD 89 28 2

TEA 179 1 DNT 176 1 DNT 177 1 DNT 169 1 DNT 178 1 DNT 126 P 3 TWD 3 17 2

TEA 22 2

SAl 22 2

TWD 65 26 2

TEA 178 1 DNT 15 2

TEA 27 2

TEA 17 2

TEA 26 2

TEA 24 2

TEA 16 2

TEA 26 2

TEA 42 2

TEA 25 2

TEA 19 2

TEA 18 2

TEA 23 2

TEA 27 2

TEA 26 2

TEA 22 2

TEA 26 2

TEA 188 1 DNT UTE UTE UTE UTE UTE 008 UTE 008 014 014 UTE LTE UTE 010 LTE LTE LTE UTE 010 004 012 012 UTE 010 013 UTE UTE UTE LTE 009 UTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE UTE 007 UTE UTE UTE UTE LTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE

-0.26

-3.35

-3.35

-0.20

-0.25

-0.69

-0.14

+0.74

+0.99

+0.97

-0.18

+10.42

-11.99

-0.65

+11.33

+10.81

+10.17

-0.20

-0.57

+1. 46

+1.15

+0.95

-0.16

+1.19

+1.20

-0.15

-0.22

-0.16

+10.75

-0.76

-11.72

+11.26

+10.66

-11. 75

-0.21

-0.19

-0.19

-3.53

-3.53

-3.66

-3.66

-0.21

-3.57

-3.57

-3.55

-3.55

-0.16

-11. 75

+10.59

+11.19

+10.40

-11.77

-0.02

-0.12

-1.20

-1.20

-0.11

+19.29

-0.13

-0.19

-0.12

-0.14

-0.14

-0.16

-0.26

-0.10

-0.20

-0.18

-0.17

-0.16

-0.17

-0.29

-0.19

-0.16

-11.00 05/02/02 13:30:25 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTS UTE UTS UTE UTE UTE UTE 008 008 WAR UTE UTE 008 008 WAR 014 014 014 014 UTE UTE LTE LTE UTE UTE 010 010 LTE LTE LTE LTE LTE LTE UTE UTE 010 010 005 004 012 012 012 012 UTE UTE 010 010 013 013 UTE UTE UTE UTE UTE UTE LTE LTE 009 009 WAR UTE UTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE UTE UTE 007 007 WAR UTE UTE UTE UTE CS UTE UTE UTE UTE LTS LTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 2042 2041 2041 2066 2042 4023 2041 4023 4023 4023 2081 4023 4023 4023 4023 4023 4023 2061 4023 4035 4055 4055 2125 4055 4055 2100 2100 2101 4055 4055 4055 4055 4055 4055 2101 2125 2100 2101 2101 2100 2100 2100 2101 2101 2100 2100 2100 4040 4040 4109 4109 4109 4040 2101 2100 2100 2101 4061 2100 2048 2047 2048 2047 2047 2048 2047 2048 2047 2047 2047 2047 2048 2047 2041 4023 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET It'lLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 120 of 155 PROBE 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460SI 460SI 460S1 460HR 460S1 460S1 46081 46081 46081 46081 460HR 460SI 46081 46081 460SI 460HR 460SI 46081 460HR 460HR 460HR 46081 46081 46081 460SI 460SI 46081 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 46081 46081 46081 46081 46081 460S1 460HR 460HR 460HR 460HR 46081 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 46081

Framatome ANP Inc.

05/02/02 13:30:27 Customer Name: Oconee Unit 1 Component: S/G B Page 121 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY; QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

115 102 4.26 25 2

TEA UTE

-0.20 UTE UTE 2061 INLET 460HR 115 103 0.47 110 P 3 TWO 8 009

+0.63 009 009 WAR 4023 INLET 460S1 5.49 29 2

TEA UTE

-0.24 UTE UTE 2061 INLET 460HR 115 107 1.28 24 2

TEA UTE

-0.28 UTE UTE 2061 INLET 460HR 115 108 5.46 182 1 ONT LTE

+10.02 LTE LTE 4023 INLET 460S1 3.95 21 2

TEA UTE

-0.17 UTE UTE 2062 INLET 460HR 115 111 4.93 186 1 ONT UTE

-12.63 UTE UTE 4023 INLET 460S1 4.64 174 1 ONT UTE

-12.93 UTE UTE 4023 INLET 460S1 10.78 180 1 ONT 010

-0.59 010 010 4023 INLET 460S1 3.18 193 1 ONT LTE

+5.84 LTE LTE 4023 INLET 460S1 6.08 187 1 ONT LTE

+6.47 LTE LTE 4023 INLET 460S1 6.12 184 1 ONT LTE

+10.56 LTE LTE 4023 INLET 460S1 7.13 183 1 ONT LTE

+11. 32 LTE LTE 4023 INLET 460S1 4.02 32 2

TEA UTE

-0.26 UTE UTE 2124 INLET 460HR 115 112 6.53 172 1 ONT 010

-0.65 010 010 4023 INLET 460S1 2.09 21 2

TEA UTE

-0.22 UTE UTE 2062 INLET 460HR 115 114 1.16 19 2

TEA UTE

-0.19 UTE UTE 2062 INLET 460HR 0.22 63 2

VOL 014

+1.04 015 014 4035 INLET 460S1 116 2 0.29 97 P 3 TWO 7 009

-0.67 009 009 WAR 4055 OUTLET 460S1 116 3 2.75 29 2

TEA UTE

-0.19 UTE UTE 2100 INLET 460HR 116 13 0.28 41 P 3 TWO 7 012

+0.76 012 012 WAR 4055 OUTLET 460S1 116 14 2.01 20 2

TEA UTE

-0.17 UTE UTE 2100 INLET 460HR 116 20 10.53 168 1 ONT UTE

-11. 33 UTE UTE 4040 INLET 460S1 10.96 166 1 ONT LTE

+10.82 LTE LTE 4040 INLET 460S1 116 28 2.06 26 2

TEA UTE

-0.17 UTE UTE 2100 INLET 460HR 0.42 14 2

VOL UTE

-1. 48 UTE UTE 2100 INLET 460HR 116 30 4.31 178 1 ONT 004

+9.16 004 004 4040 INLET 460S1 5.07 175 1 DNT 004

+10.20 004 004 4040 INLET 460S1 2.16 168 1 ONT 004

+11.20 004 004 4040 INLET 460S1 3.35 167 1 DNT 003

-0.77 003 003 4040 INLET 460S1 2.07 192 1 ONT 003

-1. 08 003 003 4040 INLET 460S1 3.22 165 1 ONT 003

+1.60 003 003 4040 INLET 460S1 3.62 167 1 ONT 003

+2.21 003 003 4040 INLET 460S1 3.91 176 1 ONT 003

+2.58 003 003 4040 INLET 460S1 2.69 172 1 ONT 003

+12.99 003 003 4040 INLET 460S1 4.25 176 1 ONT 003

+13.59 003 003 4040 INLET 460S1 4.35 176 1 ONT 003

+14.02 003 003 4040 INLET 460S1 3.49 164 1 ONT 003

+15.18 003 003 4040 INLET 460S1 3.51 158 1 DNT 003

+18.26 003 003 4040 INLET 460S1 1.52 192 1 ONT 003

+19.28 003 003 4040 INLET 460S1 2.84 168 1 ONT 003

+17.85 003 003 4040 INLET 460S1

1. 59 158 1 ONT 003

+17.30 003 003 4040 INLET 460S1 2.71 194 1 ONT 002

-2.79 002 002 4040 INLET 460S1 2.97 189 1 DNT 002

-0.44 002 002 4040 INLET 460S1 4.20 179 1 ONT 002

+0.59 002 002 4040 INLET 460S1 1.96 154 1 ONT 002

+1. 61 002 002 4040 INLET 460SI 3.16 174 1 ONT 002

+13.27 002 002 4040 INLET 460S1 4.01 171 1 ONT 002

+15.39 002 002 4040 INLET 460S1 3.46 175 1 ONT 002

+14.27 002 002 4040 INLET 460S1 116 33 1.45 23 2

TEA UTE

-0.17 UTE UTE 2101 INLET 460HR 116 40 0.60 147 P 3 TWO 14 007

+0.58 007 007 WAR 4061 OUTLET 460S1 116 42 0.64 128 P 3 TWO 15 007

+0.62 007 007 WAR 4061 OUTLET 460S1 116 53

1. 99 37 P 1 SCI UTE

-0.14 UTE UTS CL 2100 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.14 TO+138.5 UTE UTS 2100 INLET 460HR 0.39 137 P 3 TWO 4 UTE

-0.14 TO+147.7 UTE UTS 2100 INLET 460HR 0.91 28 P 3 TWO 14 UTE

-0.14 TO+l56.9 UTE UTS 2100 INLET 460HR 2.35 22 P 3 TWD 42 UTE

-0.14 TO+166.2 UTE UTS 2100 INLET 460HR 3.72 17 P 3 TWO 71 UTE

-0.14 TO+175.4 UTE UTS 2100 INLET 460HR 2.03 23 P 3 TWO 36 UTE

-0.14 TO+184.6 UTE UTS 2100 INLET 460HR 1.65 20 P 3 TWD 28 UTE

-0.14 TO+193.8 UTE UTS 2100 INLET 460HR 0.89 27 P 3 TWO 14 UTE

-0.14 TO+203.1 UTE UTS 2100 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.14 TO+212.3 UTE UTS 2100 INLET 460HR 116 55 4.56 30 2

TEA UTE

-0.15 UTE UTE 2100 INLET 460HR 116 58 1.80 24 2

TEA UTE

-0.19 UTE UTE 2048 INLET 460HR 116 63 4.37 26 2

TEA UTE

-0.33 UTE UTE 2048 INLET 460HR 116 70 2.59 16 2

TEA UTE

-0.16 UTE UTE 2047 INLET 460HR 116 71 4.07 25 2

TEA UTE

-0.43 UTE UTE 2048 INLET 460HR 116 72 0.61 17 2

TWO 42 UTE

-3.66 UTE UTS 2047 INLET 460HR 0.62 17 2

SAl UTE

-3.66 UTE UTS 2047 INLET 460HR 116 73 2.01 24 2

TEA UTE

-0.40 UTE UTE 2048 INLET 460HR 116 74 5.23 17 2

TEA UTE

-0.22 UTE UTE 2047 INLET 460HR 116 79 0.82 17 2

TEA UTE

-0.49 UTE UTE 2048 INLET 460HR 116 82 2.69 22 2

TEA UTE

-0.24 UTE UTE 2047 INLET 460HR 116 84 4.80 23 2

TEA UTE

-0.28 UTE UTE 2047 INLET 460HR 116 86 2.65 19 2

TEA UTE

-0.16 UTE UTE 2047 INLET 460HR

Framatome ANP Inc.

05/02/02 13:30:28 Customer Name: Oconee Unit 1 Component: S/G B Page 122 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -: MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

116 87 3.54 25 2

TEA UTE

-0.49 UTE UTE 2048 INLET 460HR 116 93 2.73 21 2

TEA UTE

-0.35 UTE UTE 2048 INLET 460HR 116 94 3.30 21 2

TEA UTE

-0.24 UTE UTE 2047 INLET 460HR 116 96 0.09 109 2 VOL 014

+1.19 014 014 4023 INLET 460S1 3.27 26 2

TEA UTE

-0.17 UTE UTE 2047 INLET 460HR 116 97 0.25 139 P 3 TWD 5 014

+0.71 014 014 WAR 4023 INLET 460S1 116 98 0.64 58 P 3 TWD 9 009

+0.69 009 009 WAR 4023 INLET 460S1 116 101 1.54 127 P 3 TWO 21 010

+0.66 010 010 WAR 4023 INLET 460S1 116 102

1. 07 122 P 3 TWO 16 010

+0.66 010 010 WAR 4023 INLET 460S1 116 106 0.17 101 2 VOL 010

+0.47 010 010 4023 INLET 460S1

1. 67 46 2

TEA UTE

-0.27 UTE UTE 2061 INLET 460HR 116 108 7.29 180 1 ONT UTE

-12.15 UTE UTE 4023 INLET 460S1 7.09 176 1 ONT LTE

+10.71 LTE LTE 4023 INLET 460S1 0.94 31 2

TEA UTE

-0.23 UTE UTE 2062 INLET 460HR 116 110 9.14 181 1 DNT UTE

-12.69 UTE UTE 4023 INLET 460S1 0.26 106 P 3 TWO 4 014

+0.82 014 014 WAR 4023 INLET 460S1 9.27 178 1 DNT 010

-0.55 010 010 4023 INLET 460S1 0.73 102 P 3 TWO 11 010

+0.68 010 010 WAR 4023 INLET 460SI 0.93 98 P 3 TWO 12 007

+0.67 007 007 WAR 4023 INLET 460SI 7.89 182 1 ONT LTE

+11.13 LTE LTE 4023 INLET 460S1 7.40 177 1 DNT LTE

+6.48 LTE LTE 4023 INLET 460SI 5.76 26 2

TEA UTE

-0.27 UTE UTE 2061 INLET 460HR 116 111 9.22 177 1 DNT 010

-0.64 010 010 4023 INLET 460S1 8.96 21 P 1 MCI UTE

-0.24 UTE UTS CL 2062 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.24 TO+284.4 UTE UTS 2062 INLET 460HR 1.69 30 P 3 TWO 21 UTE

-0.24 TO+293.3 UTE UTS 2062 INLET 460HR 3.18 28 P 3 TWO 40 UTE

-0.24 TO+302.2 UTE UTS 2062 INLET 460HR 3.88 21 P 3 TWO 49 UTE

-0.24 TO+311. 1 UTE UTS 2062 INLET 460HR 4.28 26 P 3 TWD 54 UTE

-0.24 TO+320.0 UTE UTS 2062 INLET 460HR 7.10 23 P 3 TWD 90 UTE

-0.24 TO+328.9 UTE UTS 2062 INLET 460HR 6.92 26 P 3 TWD 88 UTE

-0.24 TO+337.8 UTE UTS 2062 INLET 460HR 5.40 27 P 3 TWD 69 UTE

-0.24 TO+346.7 UTE UTS 2062 INLET 460HR 7.03 26 P 3 TWD 89 UTE

-0.24 TO+355.6 UTE UTS 2062 INLET 460HR 7.47 25 P 3 TWO 95 UTE

-0.24 TO+4.4 UTE UTS 2062 INLET 460HR 5.64 26 P 3 TWO 72 UTE

-0.24 TO+13.3 UTE UTS 2062 INLET 460HR 4.29 27 P 3 TWO 55 UTE

-0.24 TO+22.2 UTE UTS 2062 INLET 460HR 3.38 26 P 3 TWD 43 UTE

-0.24 TO+31.1 UTE UTS 2062 INLET 460HR 2.25 27 P 3 TWO 29 UTE

-0.24 TO+40.0 UTE UTS 2062 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.24 TO+48.9 UTE UTS 2062 INLET 460HR 7.84 20 P 1 MCI UTE

-0.23 UTE UTS CL 2062 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.23 TO+80.0 UTE UTS 2062 INLET 460HR 2.06 38 P 3 TWD 16 UTE

-0.23 TO+88.9 UTE UTS 2062 INLET 460HR 2.79 32 P 3 TWD 21 UTE

-0.23 TO+97.8 UTE UTS 2062 INLET 460HR 2.71 25 P 3 TWD 21 UTE

-0.23 TO+106.7 UTE UTS 2062 INLET 460HR

1. 91 28 P 3 TWD 15 UTE

-0.23 TO+115.6 UTE UTS 2062 INLET 460HR 2.21 33 P 3 TWO 17 UTE

-0.23 TO+124.4 UTE UTS 2062 INLET 460HR 4.80 24 P 3 TWO 37 UTE

-0.23 TO+133.3 UTE UTS 2062 INLET 460HR 7.80 20 P 3 TWO 60 UTE

-0.23 TO+142.2 UTE UTS 2062 INLET 460HR 6.63 23 P 3 TWO 51 UTE

-0.23 TO+151.1 UTE UTS 2062 INLET 460HR 5.75 23 P 3 TWD 44 UTE

-0.23 TO+160.0 UTE UTS 2062 INLET 460HR 6.47 20 P 3 TWD 50 UTE

-0.23 TO+168.9 UTE UTS 2062 INLET 460HR 6.84 18 P 3 TWD 53 UTE

-0.23 TO+177.8 UTE UTS 2062 INLET 460HR 5.56 22 P 3 TWD 43 UTE

-0.23 TO+186.7 UTE UTS 2062 INLET 460HR 3.18 19 P 3 TWD 24 UTE

-0.23 TO+195.6 UTE UTS 2062 INLET 460HR 2.59 29 P 3 TWD 20 UTE

-0.23 TO+204.4 UTE UTS 2062 INLET 460HR 3.91 32 P 3 TWD 30 UTE

-0.23 TO+213.3 UTE UTS 2062 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.23 TO+222.2 UTE UTS 2062 INLET 460HR 116 112 0.16 58 2

VOL 014

+1. 26 014 014 4023 INLET 460S1 13.61 176 1 DNT 010

-0.60 010 010 4023 INLET 460SI 11.22 176 1 DNT 010

+0.40 010 010 4023 INLET 460S1 2.45 33 2

TEA UTE

-0.26 UTE UTE 2061 INLET 460HR 116 113 2.82 27 2

TEA UTE

-0.20 UTE UTE 2062 INLET 460HR 117 4 0.30 90 2

VOL 005

+2.15 005 005 4055 OUTLET 460S1 0.39 138 2 VOL 009

-0.01 009 009 4055 OUTLET 460S1 0.27 35 P 3 TWO 7 013

+0.73 013 013 WAR 4055 OUTLET 460S1 2.49 29 2

TEA UTE

-0.19 UTE UTE 2100 INLET 460HR 117 6 6.31 182 1 ONT LTE

+11.17 LTE LTE 4055 OUTLET 460SI 7.27 181 1 ONT UTE

-11. 71 UTE UTE 4055 OUTLET 460SI

1. 82 29 2

TEA UTE

-0.18 UTE UTE 2100 INLET 460HR 117 8 2.97 27 2

TEA UTE

-0.18 UTE UTE 2100 INLET 460HR 117 13 2.00 31 2

TEA UTE

-0.18 UTE UTE 2101 INLET 460HR 117 14 0.40 93 P 3 TWD 10 014

+0.77 014 014 WAR 4055 OUTLET 460S1 117 15 0.51 36 2

SAl UTE

-3.64 UTE UTS 2101 INLET 460HR 0.51 36 2

TWD 99 UTE

-3.64 UTE UTS 2101 INLET 460HR 117 16 2.00 20 2

TEA UTE

-0.17 UTE UTE 2100 INLET 460HR

Framatome ANP Inc.

05/02/02 13:30:30 Customer Name: Oconee Unit 1 Component: S/G B Page 123 of 155 ATTACHMENT #4 - LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

117 18

1. 91 17 2

TEA UTE

-0.17 UTE UTE 2100 INLET 460HR 117 21 2.78 27 2

TEA UTE

-0.17 UTE UTE 2101 INLET 460HR 117 22 0.40 111 P 3 TWD 7 007

+0.30 007 007 WAR 4040 INLET 460S1 117 30 2.14 32 2

TEA UTE

-0.16 UTE UTE 2100 INLET 460HR 117 32 1.48 180 3 DNT LTS

+17.21 LTS LTS 4061 OUTLET 460S1 117 37 3.19 161 3 DNT 015

+22.44 015 015 4061 OUTLET 460S1 4.02 29 2

TEA UTE

-0.19 UTE UTE 2100 INLET 460HR 117 47 2.24 23 2

TEA UTE

-0.21 UTE UTE 2096 INLET 460HR 117 55 1.11 32 2

TEA UTE

-0.31 UTE UTE 2048 INLET 460HR 117 57 2.82 180 1 ONT UTE

-6.97 UTE UTE 4014 INLET 460S1 117 60 2.91 31 2

TEA UTE

-0.30 UTE UTE 2048 INLET 460HR 117 62 1.50 24 2

TEA UTE

-0.28 UTE UTE 2048 INLET 460HR 117 65 6.12 25 2

TEA UTE

-0.13 UTE UTE 2047 INLET 460HR 117 67 3.40 22 2

TEA UTE

-0.16 UTE UTE 2047 INLET 460HR 117 69 2.90 23 2

TEA UTE

-0.13 UTE UTE 2047 INLET 460HR 117 72

1. 44 23 2

TEA UTE

-0.23 UTE UTE 2048 INLET 460HR 117 73 3.17 15 2

TEA UTE

-0.19 UTE UTE 2047 INLET 460HR 117 74 3.37 26 2

TEA UTE

-0.21 UTE UTE 2048 INLET 460HR 117 76 2.17 26 2

TEA UTE

-0.37 UTE UTE 2048 INLET 460HR 117 77 4.32 18 2

TEA UTE

-0.20 UTE UTE 2047 INLET 460HR 117 78 7.39 169 1 DNT 006

-17.93 006 006 4023 INLET 460S1 117 81 1.16 23 2

TWO 68 UTE

-3.56 UTE UTS 2047 INLET 460HR 1.19 23 2

MAl UTE

-3.56 UTE UTS 2047 INLET 460HR 117 87 5.41 21 2

TEA UTE

-0.15 UTE UTE 2047 INLET 460HR 117 88 1.52 27 2

TEA UTE

-0.33 UTE UTE 2048 INLET 460HR 117 90 0.14 92 2

VOL 014

+0.99 014 014 4023 INLET 460S1 0.57 20 2

TEA UTE

-0.33 UTE UTE 2048 INLET 460HR 117 91 5.10 23 2

TEA UTE

-0.14 UTE UTE 2047 INLET 460HR 117 92 4.35 26 2

TEA UTE

-0.37 UTE UTE 2048 INLET 460HR 117 96 2.87 18 2

TEA UTE

-0.39 UTE UTE 2048 INLET 460HR 117 97 1.21 130 P 3 TWO 17 010

+0.71 010 010 WAR 4023 INLET 460SI 117 98 1.25 125 P 3 TWO 18 010

+0.64 010 010 WAR 4023 INLET 460SI 117 99 1.43 89 P 3 TWO 20 010

+0.60 010 010 WAR 4023 INLET 460S1 4.69 23 2

TEA UTE

-0.18 UTE UTE 2062 INLET 460HR 117 100 1.57 29 2

TEA UTE

-0.20 UTE UTE 2061 INLET 460HR 117 101 0.34 160 P 3 TWD 6 010

+0.04 010 010 WAR 4023 INLET 460S1 4.12 27 2

TEA UTE

-0.22 UTE UTE 2062 INLET 460HR 117 104 2.49 23 2

TEA UTE

-0.25 UTE UTE 2061 INLET 460HR 7.08 186 1 DNT UTE

-11. 61 UTE UTE 4026 INLET 460S1

1. 41 27 2

TEA UTE

-0.25 UTE UTE 4026 INLET 460SI 8.94 183 1 ONT LTE

+11.12 LTE LTE 4026 INLET 460SI 117 107 6.75 170 1 ONT 010

-0.59 010 010 4026 INLET 460S1 117 108 19.22 181 1 DNT 010

-0.37 010 010 4085 OUTLET 460SI 118 4 3.90 16 2

TEA UTE

-0.20 UTE UTE 2097 INLET 460HR 118 5 5.13 32 2

TEA UTE

-0.17 UTE UTE 2096 INLET 460HR 118 7 2.42 188 1 DNT UTE

-7.83 UTE UTE 4055 OUTLET 460SI 2.06 29 2

TEA UTE

-0.12 UTE UTE 2096 INLET 460HR 118 8 0.53 10 2

SVI UTE

-1.16 UTE UTE TR 2097 INLET 460HR 0.53 10 2

TWD 11 UTE

-1.16 UTE UTE 2097 INLET 460HR 118 10 0.20 50 2

VOL LTS

+14.34 LTS LTS 4055 OUTLET 460S1

1. 04 25 2

TEA UTE

-0.15 UTE UTE 2097 INLET 460HR 0.52 23 2

SAl UTE

-1.14 UTE UTE TR 2097 INLET 460HR 0.52 23 2

TWO 77 UTE

-1.14 UTE UTE 2097 INLET 460HR 118 11 0.90 30 2

SAl UTE

-3.55 UTE UTS 2096 INLET 460HR 0.90 30 2

TWO 89 UTE

-3.55 UTE UTS 2096 INLET 460HR 118 13 2.32 23 2

TEA UTE

-0.15 UTE UTE 2096 INLET 460HR 118 16 2.22 22 2

TEA UTE

-0.19 UTE UTE 2097 INLET 460HR 118 19 0.16 104 2 VOL 014

+0.81 014 014 4040 INLET 460SI 118 21

1. 70 32 2

TWO 99 UTE

-3.55 UTE UTS 2097 INLET 460HR

1. 70 32 2

MAl UTE

-3.55 UTE UTS 2097 INLET 460HR 0.57 37 P 1 SCI UTE

-3.55 UTE UTS 2097 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.55 TO+217.8 UTE UTS 2097 INLET 460HR 0.62 31 P 3 TWO 46 UTE

-3.55 TO+226.7 UTE UTS 2097 INLET 460HR 0.78 28 P 3 TWO 58 UTE

-3.55 TO+235.6 UTE UTS 2097 INLET 460HR 0.77 29 P 3 TWO 57 UTE

-3.55 TO+244.4 UTE UTS 2097 INLET 460HR 0.65 30 P 3 TWO 48 UTE

-3.55 TO+253.3 UTE UTS 2097 INLET 460HR 0.59 25 P 3 TWD 43 UTE

-3.55 TO+262.2 UTE UTS 2097 INLET 460HR 0.72 28 P 3 TWO 54 UTE

-3.55 TO+271.1 UTE UTS 2097 INLET 460HR 0.69 34 P 3 TWO 51 UTE

-3.55 TO+280.0 UTE UTS 2097 INLET 460HR 0.92 33 P 3 TWO 68 UTE

-3.55 TO+288.9 UTE UTS 2097 INLET 460HR 0.97 39 P 3 TWO 71 UTE

-3.55 TO+297.8 UTE UTS 2097 INLET 460HR 1.14 34 P 3 TWO 83 UTE

-3.55 TO+306.7 UTE UTS 2097 INLET 460HR 1.23 33 P 3 TWO 88 UTE

-3.55 TO+315.6 UTE UTS 2097 INLET 460HR 1.28 34 p 3 TWD 92 UTE

-3.55 TO+324.4 UTE UTS 2097 INLET 460HR 1.26 33 P 3 TWD 90 UTE

-3.55 TO+333.3 UTE UTS 2097 INLET 460HR

Framatome ANP Inc.

05/02/02 13:30:31 Customer Name: Oconee unit 1 Component: S/G B Page 124 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -. MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

1.32 33 P 3 TWO 94 UTE

-3.55 TO+342.2 UTE UTS 2097 INLET 460HR 1.23 35 P 3 TWO 89 UTE

-3.55 TO+351.1 UTE UTS 2097 INLET 460HR 1.00 35 P 3 TWO 74 UTE

-3.55 TO+O.O UTE UTS 2097 INLET 460HR 0.89 34 P 3 TWO 66 UTE

-3.55 TO+8.9 UTE UTS 2097 INLET 460HR 0.87 36 P 3 TWO 64 UTE

-3.55 TO+17.8 UTE UTS 2097 INLET 460HR 0.69 36 P 3 TWO 51 UTE

-3.55 TO+26.7 UTE UTS 2097 INLET 460HR 0.20 35 P 3 TWO 11 UTE

-3.55 TO+35.6 UTE UTS 2097 INLET 460HR 0.38 26 p 3 TWO 27 UTE

-3.55 TO+44.4 UTE UTS 2097 INLET 460HR 0.44 25 P 3 TWO 32 UTE

-3.55 TO+53.3 UTE UTS 2097 INLET 460HR 0.50 32 p 3 TWO 36 UTE

-3.55 TO+62.2 UTE UTS 2097 INLET 460HR 0.57 35 P 3 TWO 42 UTE

-3.55 TO+71.1 UTE UTS 2097 INLET 460HR 0.68 36 p 3 TWO 51 UTE

-3.55 TO+80.0 UTE UTS 2097 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.55 TO+88.9 UTE UTS 2097 INLET 460HR 118 22 5.45 167 1 ONT 011

+14.73 011 011 4040 INLET 460SI 118 24 3.42 26 2

TEA UTE

-0.14 UTE UTE 2096 INLET 460HR 0.68 21 2

SVI UTE

-0.92 UTE UTE TR 2096 INLET 460HR 0.68 21 2

TWO 59 UTE

-0.92 UTE UTE 2096 INLET 460HR 1.23 23 2

SVI UTE

-1. 30 UTE UTE TR 2096 INLET 460HR 1.23 23 2

TWO 66 UTE

-1. 30 UTE UTE 2096 INLET 460HR 0.70 30 2

SVI UTE

-1. 67 UTE UTE CS 2096 INLET 460HR 0.70 30 2

TWO 89 UTE

-1.67 UTE UTE 2096 INLET 460HR 118 35

1. 50 14 2

TEA UTE

-0.13 UTE UTE 2097 INLET 460HR 118 37 1.32 12 2

TEA UTE

-0.16 UTE UTE 2097 INLET 460HR 118 38

1. 00 56 2

TEA UTE

-0.14 UTE UTE 2096 INLET 460HR 118 44 0.95 13 2

TEA UTE

-0.19 UTE UTE 2096 INLET 460HR 118 49

1. 78 20 2

TEA UTE

-0.17 UTE UTE 2097 INLET 460HR 118 50

1. 50 29 2

TEA UTE

-0.13 UTE UTE 2096 INLET 460HR 118 51 2.55 28 2

TEA UTE

-0.17 UTE UTE 2097 INLET 460HR 118 52 0.73 30 2

SAl UTE

-3.57 UTE UTS 2096 INLET 460HR 0.73 30 2

TWO 89 UTE

-3.57 UTE UTS 2096 INLET 460HR 118 58 3.69 20 2

TEA UTE

-0.17 UTE UTE 2047 INLET 460HR 118 59 3.80 26 2

TEA UTE

-0.33 UTE UTE 2048 INLET 460HR 118 60 5.45 159 1 ONT LTS

-13.69 LTS LTS 4015 INLET 460SI 118 61 5.55 25 2

TEA UTE

-0.32 UTE UTE 2048 INLET 460HR 118 62 4.10 14 2

TEA UTE

-0.17 UTE UTE 2047 INLET 460HR 118 63 2.65 26 2

TEA UTE

-0.36 UTE UTE 2048 INLET 460HR 118 67 3.26 23 2

TEA UTE

-0.27 UTE UTE 2048 INLET 460HR 118 70 1.17 26 2

TWO 84 UTE

-3.23 UTE UTS 2047 INLET 460HR

1. 04 27 2

8AI UTE

-3.23 UTE UT8 2047 INLET 460HR 118 71 3.04 23 2

TEA UTE

-0.47 UTE UTE 2048 INLET 460HR 118 73 3.06 23 2

TEA UTE

-0.32 UTE UTE 2048 INLET 460HR 118 74 3.48 22 2

TEA UTE

-0.22 UTE UTE 2047 INLET 460HR 118 76 5.62 27 2

TEA UTE

-0.27 UTE UTE 2047 INLET 460HR 118 91 2.32 20 P 1 SCI UTE

-0.26 UTE UT8 CL 2047 INLET 460HR 0.26 355 P 3 TWO 0 UTE

-0.26 TO+244.4 UTE UT8 2047 INLET 460HR 0.32 354 P 3 TWO 23 UTE

-0.26 TO+235.6 UTE UTS 2047 INLET 460HR

1. 08 16 P 3 TWO 42 UTE

-0.26 TO+226.7 UTE UTS 2047 INLET 460HR

1. 55 17 P 3 TWO 50 UTE

-0.26 TO+217.8 UTE UT8 2047 INLET 460HR 0.87 16 P 3 TWO 38 UTE

-0.26 TO+208.9 UTE UT8 2047 INLET 460HR 0.35 356 P 3 TWO 0 UTE

-0.26 TO+200.0 UTE UTS 2047 INLET 460HR 118 92

1. 97 27 2

TEA UTE

-0.32 UTE UTE 2048 INLET 460HR 118 93 1.50 10 2

TEA UTE

-0.20 UTE UTE 2047 INLET 460HR 118 95 2.05 27 2

TEA UTE

-0.31 UTE UTE 2048 INLET 460HR 118 98 3.30 27 2

TEA UTE

-0.19 UTE UTE 2061 INLET 460HR 0.52 148 P 3 TWO 11 010

+0.61 010 010 WAR 4026 INLET 46081 118 99

1. 08 80 P 3 TWO 15 010

+0.65 010 010 WAR 4026 INLET 46081 118 100 0.57 0

P 3 TWO 9 009

+0.64 009 009 WAR 4026 INLET 460SI 118 104 6.58 185 1 ONT UTE

-11. 63 UTE UTE 4026 INLET 460SI 10.61 182 1 ONT LTE

+11.59 LTE LTE 4026 INLET 460S1 118 105 11.74. 180 1 ONT UTE

-11. 88 UTE UTE 4026 INLET 460SI 3.84 180 1 ONT LTE

+11. 06 LTE LTE 4026 INLET 460SI 118 106 7.14 173 1 ONT 010

-0.42 010 010 4026 INLET 46081 118 107 18.29 181 1 ONT 010

-0.13 010 010 4085 OUTLET 460SI

1. 68 25 2

TEA UTE

-0.22 UTE UTE 2062 INLET 460HR 119 3 3.33 30 2

TEA UTE

-0.15 UTE UTE 2096 INLET 460HR 119 4 3.80 23 2

TEA UTE

-0.16 UTE UTE 2097 INLET 460HR 119 5 0.40 105 P 3 TWO 10 010

+0.47 010 010 WAR 4055 OUTLET 460SI 0.27 101 P 3 TWO 7 011

+0.72 011 011 WAR 4055 OUTLET 460SI 0.60 105 P 3 TWO 14 012

+0.67 012 012 WAR 4055 OUTLET 460SI 4.80 33 2

TEA UTE

-0.16 UTE UTE 2096 INLET 460HR 119 6 2.88 185 1 ONT UTE

-10.48 UTE UTE 4055 OUTLET 460S1 2.80 183 1 ONT UTE

-9.46 UTE UTE 4055 OUTLET 46081 119 9 4.95 179 1 ONT LTS

+10.81 LTS LTS 4055 OUTLET 460SI 3.60 33 2

TEA UTE

-0.11 UTE UTE 2096 INLET 460HR 119 11

1. 01 6

2 TEA UTE

-0.12 UTE UTE 2096 INLET 460HR

Framatome ANP Inc.

05/02/02 13:30:33 Customer Name: Oconee Unit 1 Component: S/G B Page 125 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -. MRPC/PLUS POINT QUERY: QueryMI ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============

==========::;:

119 14

1. 47 28 2

TWO 94 UTE

-3.54 UTE UTS 2097 INLET 460HR

1. 47 28 2

MAl UTE

-3.54 UTE UTS 2097 INLET 460HR 119 15 5.09 30 2

TEA UTE

-0.18 UTE UTE 2096 INLET 460HR 119 17 4.41 28 2

TEA UTE

-0.18 UTE UTE 2096 INLET 460HR 119 19 2.39 21 2

TEA UTE

-0.08 UTE UTE 2097 INLET 460HR 119 23 2.73 20 2

TEA UTE

-0.09 UTE UTE 2097 INLET 460HR 119 25

1. 68 13 2

TEA UTE

-0.13 UTE UTE 2097 INLET 460HR 119 34 3.43 174 1 ONT 012

-18.86 012 012 4061 OUTLET 460SI 119 39 0.30 31 P 1 SCI UTE

-1.10 UTE UTE TR 2097 INLET 460HR 0.15 42 P 3 TWO 39 UTE

-1.10 TO+252.0 UTE UTE 2097 INLET 460HR 0.26 37 P 3 TWO 66 UTE

-1.10 TO+243.0 UTE UTE 2097 INLET 460HR 0.35 30 P 3 TWO 88 UTE

-1.10 TO+234.0 UTE UTE 2097 INLET 460HR 0.19 32 P 3 TWO 48 UTE

-1.10 TO+225.0 UTE UTE 2097 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-1.10 TO+216.0 UTE UTE 2097 INLET 460HR 0.14 35 P 1 SCI UTE

-0.82 UTE UTE CS 2097 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.82 TO+315.0 UTE UTE 2097 INLET 460HR 0.16 32 P 3 TWO 66 UTE

-0.82 TO+306.0 UTE UTE 2097 INLET 460HR 0.22 26 P 3 TWO 80 UTE

-0.82 TO+297.0 UTE UTE 2097 INLET 460HR*

0.08 13 P 3 TWO 41 UTE

-0.82 TO+288.0 UTE UTE 2097 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.82 TO+279.0 UTE UTE 2097 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-1.10 TO+2610 0 UTE UTE 2097 INLET 460HR 119 42

1. 44 20 2

SAl UTE

-3.58 UTE UTS 2096 INLET 460HR

1. 44 20 2

TWO 56 UTE

-3.58 UTE UTS 2096 INLET 460HR 119 43 3.16 11 2

TEA UTE

-0.09 UTE UTE 2097 INLET 460HR 119 44 1.02 19 P 1 SCI UTE

-3.74 UTE UTS 2096 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.74 TO+46.2 UTE UTS 2096 INLET 460HR 0.25 149 P 3 TWO 37 UTE

-3.74 TO+55.4 UTE UTS 2096 INLET 460HR 0.24 146 P 3 TWO 36 UTE

-3.74 TO+64.6 UTE UTS 2096 INLET 460HR 0.24 138 P 3 TWO 36 UTE

-3.74 TO+73.8 UTE UTS 2096 INLET 460HR 0.24 138 P 3 TWO 36 UTE

-3.74 TO+83.1 UTE UTS 2096 INLET 460HR 0.22 133 P 3 TWO 33 UTE

-3.74 TO+92.3 UTE UTS 2096 INLET 460HR 0.23 88 P 3 TWO 33 UTE

-3.74 TO+1010 5 UTE UTS 2096 INLET 460HR 0.23 91 P 3 TWO 34 UTE

-3.74 TO+ll0.8 UTE UTS 2096 INLET 460HR 0.28 70 P 3 TWO 41 UTE

-3.74 TO+120.0 UTE UTS 2096 INLET 460HR 0.35 62 P 3 TWO 49 UTE

-3.74 TO+129.2 UTE UTS 2096 INLET 460HR 0.53 41 P 3 TWO 71 UTE

-3.74 TO+138.5 UTE UTS 2096 INLET 460HR 0.54 44 P 3 TWO 73 UTE

-3.74 TO+147.7 UTE UTS 2096 INLET

.460HR 0.53 41 P 3 TWO 72 UTE

-3.74 TO+156.9 UTE UTS 2096 INLET 460HR 0.62 36 P 3 TWO 81 UTE

-3.74 TO+166.2 UTE UTS 2096 INLET 460HR 0.66 36 P 3 TWO 86 UTE

-3.74 TO+175.4 UTE UTS 2096 INLET 460HR 0.73 30 P 3 TWO 93 UTE

-3.74 TO+184.6 UTE UTS 2096 INLET 460HR 0.65 31 P 3 TWO 84 UTE

-3.74 TO+193.8 UTE UTS 2096 INLET 460HR 0.60 37 P 3 TWO 79 UTE

-3.74 TO+203.1 UTE UTS 2096 INLET 460HR 0.50 44 P 3 TWO 68 UTE

-3.74 TO+212.3 UTE UTS 2096 INLET 460HR 0.43 46 P 3 TWO 59 UTE

-3.74 TO+2210 5 UTE UTS 2096 INLET 460HR 0.44 29 P 3 TWO 60 UTE

-3.74 TO+230.8 UTE UTS 2096 INLET 460HR 0.51 31 P 3 TWO 69 UTE

-3.74 TO+240.0 UTE UTS 2096 INLET 460HR 0.40 48 P 3 TWO 56 UTE

-3.74 TO+249.2 UTE UTS 2096 INLET 460HR 0.31 48 P 3 TWO 44 UTE

-3.74 TO+258.5 UTE UTS 2096 INLET 460HR 0.26 64 P 3 TWO 38 UTE

-3.74 TO+267.7 UTE UTS 2096 INLET 460HR 0.28 50 P 3 TWO 40 UTE

-3.74 TO+276.9 UTE UTS 2096 INLET 460HR 0.22 73 P 3 TWO 32 UTE

-3.74 TO+286.2 UTE UTS 2096 INLET 460HR 0.18 70 P 3 TWO 28 UTE

-3.74 TO+295.4 UTE UTS 2096 INLET 460HR 0.20 131 P 3 TWO 29 UTE

-3.74 TO+304.6 UTE UTS 2096 INLET 460HR 0.15 135 P 3 TWO 23 UTE

-3.74 TO+313.8 UTE UTS 2096 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.74 TO+323.1 UTE UTS 2096 INLET 460HR 119 50 0.84 17 2

TEA UTE

-0.15 UTE UTE 2096 INLET 460HR 119 54 0.35 51 P 3 TWO 9 007

-0.14 007 007 WAR 4061 OUTLET 460S1 119 62 1.84 23 2

TEA UTE

-0.28 UTE UTE 2051 INLET 460HR 119 63 0.85 27 2

TWO 99 UTE

-3.28 UTE UTS 2052 INLET 460HR 0.85 27 2

MAl UTE

-3.28 UTE UTS TR 2052 INLET 460HR 119 65 1.26 23 2

TWO 90 UTE

-3.24 UTE UTS 2052 INLET 460HR 1.26 23 2

MAl UTE

-3.24 UTE UTS TR 2052 INLET 460HR 119 72 2.81 25 2

TEA UTE

-0.52 UTE UTE 2048 INLET 460HR 119 76 3.77 29 2

TEA UTE

-0.33 UTE UTE 2048 INLET 460HR 119 78 3.06 25 2

TEA UTE

-0.25 UTE UTE 2048 INLET 460HR 119 82 0.55 71 2

VOL 014

+0.69 014 014 4023 INLET 460S1 119 87 7.37 26 2

TEA UTE

-0.17 UTE UTE 2047 INLET 460HR 119 90 2.66 25 2

TEA UTE

-0.33 UTE UTE 2048 INLET 460HR 119 95 0.18 97 2

VOL 014

+1.25 014 014 4085 OUTLET 460S1 119 100 2.39 26 2

TEA UTE

-0.18 UTE UTE 2062 INLET 460HR

1. 35 91 P 3 TWO 18 010

+0.43 010 010 WAR 4026 INLET 460S1 119 102 2.40 24 2

TEA UTE

-0.17 UTE UTE 2080 INLET 460HR 119 103 4.24 25 2

TEA UTE

-0.19 UTE UTE 2062 INLET 460HR 119 104 3.70 25 2

TEA UTE

-0.19 UTE UTE 2080 INLET 460HR

Framatome ANP Inc.

Customer Name: Oconee unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION 119 108 120 3 120 5 120 7 120 8 120 9 120 11 120 12 120 14 120 15 120 21 120 36 120 37 120 38 120 42 120 47 120 50 120 53 120 58 120 66 120 72 120 73 120 76 120 78 120 83 120 84 120 87 120 92 120 93 120 94 120 98 120 100 120 101 120 105 120 106 121 2 121 3 121 4 121 5 121 6 121 8 121 9 121 10 6.81 1.04 2.00 3.24 3.93 2.33

1. 35 0.88 0.48 0.36 0.75 8.86 0.35 0.48 10.06 0.28 0.34 2.32 0.27
1. 62 4.55 0.13 7.14 8.11 7.97 0.38 8.05 2.37
1. 69 1.07 0.92 0.92 2.16 6.73 1.31 2.89 2.29 2.76
1. 57 2.06 0.53 2.16 2.54 4.51 2.25 4.12 2.46 4.68 1.29 3.14 2.47 2.09 2.35
1. 70 0.26 0.18
1. 91 0.39 0.34 2.34 7.74 7.36 8.92 2.69 78.01 8.11 0.80 5.36 0.44 0.44 0.36 3.23 2.47 0.39 2.73 P 1 P 3 P 3 P 3 P 3 P 3 P 3 P 3 2

SCI TWD 0 48 61 67 52 39 o

TWD TWD TWD TWO TWD TWO VOL 27 22 22 24 22 16 14 20 89 101 21 183 44 74 185 48 46 20 P 3 TWO 9 2

TEA 1

ONT P 3 TWD 9 P 3 TWD 12 1

ONT P 3 TWD 7 P 3 TWD 8 2

TEA 3 TWD 7 TEA TEA VOL DNT DNT DNT 50 P

26 2

32 2

64 2

181 1 180 1 181 1 46 P 3 181 1 27 2

21 2

36 2

22 2

22 2

27 2

31 2

11 2

17 2

33 2

19 2

31 2

19 2

69 P

20 2

21 2

25 2

24 2

27 2

26 2

184 1 17 2

20 2

27 2

28 2

30 2

29 2

21 TWD 10 ONT TEA TEA TEA SAl TWD 62 TEA TEA TEA TEA TEA TEA TEA TEA 3 TWD 8 TEA TEA TEA TEA TEA TEA DNT TEA TEA TEA TEA TEA TEA 39 28 P 3 TWO 5 P 3 TWO 4 2

TEA 100 P 106 P 23 2

179 1 179 1 179 1 25 2

29 1

1 3 TWO 6 3 TWO 7 TEA DNT DNT ONT TEA SCI ONT 3 TWO 17 ONT SAl 171 94 P

182 1 25 2

25 2

43 TWD 72 P 3 TWD 9 2

TEA 30 31 74 36 2

P 2

TEA 3 TWD 10 TEA UTE UTE UTE UTE UTE UTE UTE UTE 015 012 UTE LTE 009 010 UTE 010 010 UTE 008 UTE UTE 002 LTE UTE LTE 008 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 007 UTE UTE UTE UTE UTE UTE 008 UTE UTE UTE UTE UTE UTE 010 009 UTE 010 013 UTE LTE UTE UTE UTE LTE LTE 010 UTE UTE UTE 008 UTE UTE 009 UTE

-0.25

-0.25

-0.25

-0.25

-0.25

-0.25

-0.25

-0.25

+0.60

+0.74

-0.16

+11.32

-0.34

+0.66

-11. 82

+0.50

+0.61

-0.16

+0.74

-0.14

-0.17

+1. 24

+11. 60

-11. 60

+11. 59

+0.71

-11. 90

-0.13

-0.13

-0.11

-1.16

-1.16

-0.16

-0.13

-0.12

-0.12

-0.12

-0.11

-0.27

-0.45

-0.23

-0.65

-0.16

-0.25

-0.28

-0.10

-0.30

-4.69

-0.12

-0.17

-0.16

-0.27

-0.24

-0.18

+0.63

-0.69

-0.18

+0.67

-0.72

-0.16

+11. 23

-9.37

-11.46

-0.13

+1.29

+11.31

+0.70

-11.49

-3.54

-3.54

+0.46

-0.16

-0.19

-0.75

-0.19 TO+13.3 TO+4.4 TO+355.6 TO+346.7 TO+337.8 TO+328.9 TO+320.0 05/02/02 13:30:34 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS 015 015 012 012 UTE UTE LTE LTE 009 009 010 010 UTE UTE 010 010 010 010 UTE UTE 008 008 UTE UTE UTE UTE 002 002 LTE LTE UTE UTE LTE LTE 008 008 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 007 007 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 008 008 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 010 009 009 UTE UTE 010 010 013 013 UTE UTE LTE LTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE 010 010 UTE UTE UTE UTS UTE UTS 008 008 UTE UTE UTE UTE 009 009 UTE UTE CL WAR WAR WAR WAR WAR WAR WAR TR WAR WAR WAR WAR WAR WAR WAR WAR 2062 2062 2062 2062 2062 2062 2062 2062 4032 4055 2097 4055 4055 4055 4055 4055 4055 2097 4055 2096 2096 4055 4055 4055 4055 4055 4055 2096 2097 2096 2096 2096 2097 2096 2096 2097 2096 2097 2051 2051 4015 2051 2052 2051 2051 2052 2051 4023 2051 2052 2051 2061 2061 2062 4026 4026 2062 4026 4026 2096 4055 4055 4055 2097 708 4056 4056 4056 2096 2096 4055 2096 2096 4055 2096 INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET OUTLET OUTLET

.OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET INLET OUTLET INLET Page 126 of 155 PROBE 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460S1 460HR 460SI 460HR 460HR 460SI 460SI 460S1 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460HR 380EX 460S1 460SI 460SI 460HR 460HR 460SI 460HR 460HR 460SI 460HR

Framatome ANP Inc.

05/02/02 13:30:36 Customer Name: Oconee Unit 1 Component: S/G B Page 127 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

121 11 0.23 72 2

VOL 002

+0.76 002 002 4055 OUTLET 460SI 4.03 23 2

TEA UTE

-0.16 UTE UTE 2097 INLET 460HR 121 13 7.11 184 1 ONT UTE

-11. 95 UTE UTE 4055 OUTLET 460SI 4.48 24 2

TEA UTE

-0.17 UTE UTE 2097 INLET 460HR 121 15 7.95 177 1 ONT LTE

+11.59 LTE LTE 4055 OUTLET 460SI 6.88 177 1 ONT UTE

-11.78 UTE UTE 4055 OUTLET 460SI 121 16 0.91 17 2

TEA UTE

-0.14 UTE UTE 2097 INLET 460HR 121 17 2.78 28 2

TEA UTE

-0.13 UTE UTE 2096 INLET 460HR 121 22 2.48 26 2

TEA UTE

-0.14 UTE UTE 2096 INLET 460HR 121 23 7.02 358 1 ONT 001

-6.85 001 001 4060 OUTLET 460SI 0.41 101 2 VOL 001

-6.79 001 001 4060 OUTLET 460SI 4.68 25 2

TEA UTE

-0.17 UTE UTE 2097 INLET 460HR 121 25 0.28 148 P 3 TWO 7 009

-0.67 009 009 WAR 4060 OUTLET 460SI 121 27 2.48 22 2

TEA UTE

-0.17 UTE UTE 2097 INLET 460HR 121 28 2.86 23 2

TEA UTE

-0.20 UTE UTE 2096 INLET 460HR 121 41 1.20 15 2

TEA UTE

-0.08 UTE UTE 2097 INLET 460HR 121 42

1. 98 23 2

TEA UTE

-0.18 UTE UTE 2096 INLET 460HR 121 45 4.38 22 2

TEA UTE

-0.16 UTE UTE 2097 INLET 460HR 121 50 3.11 29 2

TEA UTE

-0.21 UTE UTE 2096 INLET 460HR 121 51 2.21 24 2

TEA UTE

-0.13 UTE UTE 2097 INLET 460HR 121 52 2.67 18 2

TEA UTE

-0.14 UTE UTE 2096 INLET 460HR 121 53 6.53 22 2

TEA UTE

-0.15 UTE UTE 2097 INLET 460HR 121 55

1. 60 38 2

TEA UTE

-0.39 UTE UTE 2051 INLET 460HR 121 58 0.35 40 2

VOL UTE

-2.80 UTE UTE 2052 INLET 460HR 121 59

1. 98 30 2

TEA UTE

-0.10 UTE UTE 2051 INLET 460HR 121 70

1. 50 26 2

TEA UTE

-0.26 UTE UTE 2051 INLET 460HR 121 74 0.07 72 2

VOL 015

+5.68 015 015 4023 INLET 460SI 121 75 4.10 20 2

TEA UTE

-0.09 UTE UTE 2052 INLET 460HR 121 80 1.53 33 2

TEA UTE

-0.41 UTE UTE 2051 INLET 460HR 121 85 4.91 20 2

TEA UTE

-0.12 UTE UTE 2052 INLET 460HR 121 90 7.47 186 1 ONT UTE

-10.78 UTE UTE 4023 INLET 460SI

11. 39 180 1 ONT LTE

+10.58 LTE LTE 4023 INLET 46081 121 91 7.52 183 1 ONT UTE

-10.75 UTE UTE 4023 INLET 46081 7.29 181 1 ONT UTE

-9.40 UTE UTE 4023 INLET 46081 3.70 175 1 ONT LTE

+11.14 LTE LTE 4085 OUTLET 46081 121 92 8.89 182 1 ONT UTE

-9.55 UTE UTE 4023 INLET 460S1 5.20 181 1 ONT LTE

+11. 66 LTE LTE 4023 INLET 46081 2.51 16 2

TEA UTE

-0.15 UTE UTE 2052 INLET 460HR 121 94 0.43 78 2

VOL 008

+0.49 008 008 4023 INLET 46081 121 96 3.65 21 2

TEA UTE

-0.13 UTE UTE 2052 INLET 460HR 121 99 1.07 106 P 3 TWO 14 010

+0.61 010 010 WAR 4023 INLET 46081 3.87 25 2

TEA UTE

-0.23 UTE UTE 2061 INLET 460HR 121 100 3.28 27 2

TEA UTE

-0.22 UTE UTE 2062 INLET 460HR 121 102 0.33 32 P 3 TWO 6 009

+0.07 009 009 WAR 4023 INLET 46081 2.76 25 2

TEA UTE

-0.17 UTE UTE 2062 INLET 460HR 121 103 0.34 23 P 3 TWO 7 009

+0.65 009 009 WAR 4026 INLET 46081 121 104 0.89 93 P 3 TWO 17 010

+0.58 010 010 WAR 4026 INLET 46081 121 106

1. 55 24 2

TEA UTE

-0.21 UTE UTE 2062 INLET 460HR 122 1 7.37 185 1 ONT LTE

+10.54 LTE LTE 4056 OUTLET 46081 2.29 24 2

TEA UTE

-0.16 UTE UTE 2092 INLET 460HR

1. 02 30 P 1 8CI UTE

-0.26 UTE UTE CL 2092 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.26 TO+91.1 UTE UTE 2092 INLET 460HR 0.30 39 P 3 TWO 25 UTE

-0.26 TO+100.3 UTE UTE 2092 INLET 460HR 0.45 32 P 3 TWO 37 UTE

-0.26 TO+109.4 UTE UTE 2092 INLET 460HR 0.35 41 P 3 TWO 29 UTE

-0.26 TO+118.5 UTE UTE 2092 INLET 460HR 0.40 25 P 3 TWO 34 UTE

-0.26 TO+127.6 UTE UTE 2092 INLET 460HR 0.53 23 P 3 TWO 45 UTE

-0.26 TO+136.7 UTE UTE 2092 INLET 460HR 0.46 26 P 3 TWO 39 UTE

-0.26 TO+145.8 UTE UTE 2092 INLET 460HR 0.76 19 P 3 TWO 67 UTE

-0.26 TO+154.9 UTE UTE 2092 INLET 460HR 0.79 21 P 3 TWO 70 UTE

-0.26 TO+164.1 UTE UTE 2092 INLET 460HR 0.46 24 P 3 TWO 38 UTE

-0.26 TO+173.2 UTE UTE 2092 INLET 460HR 0.10 103 P 3 TWO 10 UTE

-0.26 TO+182.3 UTE UTE 2092 INLET 460HR 0.13 31 P 3 TWO 12 UTE

-0.26 TO+191. 4 UTE UTE 2092 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.26 TO+200.5 UTE UTE 2092 INLET 460HR 122 2 6.33 181 1 ONT LTE

+10.58 LTE LTE 4056 OUTLET 46081 0.26 68 2

VOL 013

+1. 27 013 013 4056 OUTLET 46081 7.52 182 1 ONT UTE

-9.46 UTE UTE 4056 OUTLET 46081 122 3 42.44 18 1

MCI LTE

+2.49 LTE LTE 708 OUTLET 380EX 122 5

1. 85 168 1 ONT UTE

-9.62 UTE UTE 4056 OUTLET 460SI 122 6 0.64 18 2

SAl UTE

-1. 03 UTE UTE TR 2093 INLET 460HR 0.64 18 2

TWO 46 UTE

-1.03 UTE UTE 2093 INLET 460HR 122 7 0.47 112 P 3 TWO 10 010

+0.57 010 010 WAR 4056 OUTLET 460S1 122 8 0.20 126 P 3 TWO 4 010

+0.45 010 010 WAR 4056 OUTLET 460S1 122 9 0.55 0

P 3 TWO 12 010

+0.45 010 010 WAR 4056 OUTLET 46081 122 13 4.16 168 1 ONT LTE

+11.35 LTE LTE 4056 OUTLET 46081

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC!PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 122 14 122 16 122 23 122 24 122 33 122 34 122 39 122 46 122 47 122 53 122 56 122 57 122 61 122 63 122 67 122 68 122 69 122 71 122 75 122 78 122 82 122 89 122 92 122 93 122 94 122 96 122 98 122 100 122 101 122 102 122 103 122 105 123 1 123 2 123 3 123 5 6.18 6.78 2.14 0.36 0.36 2.39 5.96 8.50 5.34 0.14 0.25

1. 95 2.90 3.08 3.46 2.80 3.47 6.71 2.06
1. 48 2.79 0.89 0.89 5.10 0.87 2.85 4.99 0.26
1. 03 3.00 2.19 2.84
1. 72 3.25 2.62 6.41 2.59 7.83 6.65 7.66 12.26 10.49 1.29
1. 29 5.56 5.94 1.12
1. 32 0.43 0.15 0.40 0.52 2.34 0.31
1. 60 3.14 0.54
1. 60 0.45 0.19 0.50
1. 71 4.38 0.39 49.67 36.06 10.01 0.35 9.83 3.22 6.65 0.27 7.59 2.65 0.31 ONT ONT TEA SVI TWO 99 ONT ONT ONT TEA VOL 3 TWO 6 TEA ONT ONT ONT ONT ONT TEA TEA TEA TEA SAl TWO 59 TEA TEA TEA TEA VOL TEA TEA TEA TEA TEA ONT ONT ONT TEA ONT ONT ONT ONT ONT TWO 50 SAl ONT TEA SAl TWO 50 VOL VOL VOL 184 1 181 1 18 2

36 2

34 2

183 1 180 1 180 1 24 2

52 2

147 P 20 2

167 1 163 1 169 1 170 1 168 1 24 2

15 2

19 2

24 2

21 2

21 2

27 2

25 2

19 2

25 2

1102 25 2

196 2 23 2

24 2

24 2

178 1 178 1 182 1 16 2

176 1 174 1 177 1 179 1 182 1 18 2

18 2

179 1 28 2

18 2

18 2

79 2

108 2 66 2

156 25 147 148 26 P 3 TWO S 2

TEA P 3 TWO 5 P 3 TWO 19 2

TEA 31 20 P 3 TWO 9 2

TEA 78 9

PLP 2

VOL 63 156 P 24 2

25 2

88 9

18 1

24 1

178 1 147 2 180 1 30 2

179 1 8S 2

lSI 1 24 2

3 TWO 8 TEA TEA PLP MCI MCI ONT VOL ONT TEA ONT VOL ONT TEA 47 P 3 TWO S UTE UTE UTE UTE UTE LTE LTE UTE UTE 013 009 UTE LTS LTS LTS UTS UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 UTE UTE UTE UTE UTE LTS LTS LTS UTE UTE UTE LTE LTE UTE UTE UTE LTE UTE UTE UTE OOS 008 008 OOS UTE 009 010 UTE 009 UTE 014 014 010 UTE UTE 014 LTE LTE LTE 007 UTE UTE LTE 003 UTE UTE 010

-11. 25

-11.7S

-0.20

-1. 08

-1. 08

+10.65

+11. 06

-11. 59

-0.16

+1.05

-0.64

-0.19

-10.43

-9.43

-8.50

+12.27

+11. 24

-0.19

-0.19

-O.lS

-0.16

-2.3S

-2.38

-0.17

-0.30

-0.19

-0.21

-3.91

-0.20

-0.17

-0.15

-0.26

-O.lS

+12.12

+11. 14

-15.16

-0.09

-10.20

-10.S9

+11.23

+10.44

-9.38

-1.19

-1.19

+11.46

-0.19

-1.23

-1.23

+0.S4

+1.57

+1.03

+0.23

-0.25

-0.61

+0.58

-0.27

+0.38

-0.49

+0.97

+1. 01

+0.62

-0.21

-0.18

+1.15

+0.70

+1. 41

+11.36

-0.39

-8.04

-0.17

+11.30

+0.90

-9.62

-0.22

+0.64 05/02/02 13:30:37 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE UTE UTE UTE UTE TR UTE UTE LTE LTE LTE LTE UTE UTE UTE UTE 013 013 009 009 WAR UTE UTE LTS LTS LTS LTS LTS LTS UTS UTS UTS UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE CS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTS LTS LTS LTS LTS LTS UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE TR LTE LTE UTE UTE UTE UTE UTE UTE OOS OOS OOS OOS OOS OOS OOS 008 WAR UTE UTE 009 009 WAR 010 010 WAR UTE UTE 009 009 WAR UTE UTE 014 014 014 014 010 010 WAR UTE UTE UTE UTE 014 014 LTE LTE LTE LTE LTE LTE 007 007 UTE UTE UTE UTE LTE LTE 003 003 UTE UTE UTE UTE 010 010 WAR 4056 4056 2092 2092 2092 4056 4056 4056 2093 4056 4060 2093 4061 4061 4061 4061 4061 2093 2092 2093 2096 2096 2096 2096 2051 2052 2052 4015 2051 2052 2051 2051 2051 4023 4023 4023 2052 4023 4023 4023 4023 4023 4023 4023 4023 2051 2051 2051 4023 4023 4023 4023 2061 4023 4023 2061 4023 2061 4023 4023 4023 2062 2062 4032 708 70S 4109 4109 4109 2092 4056 4056 4056 2093 4056 OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET Page 128 of 155 PROBE 460S1 460SI 460HR 460HR 460HR 460SI 460SI 460SI 460HR 460S1 460SI 460HR 460S1 460S1 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460S1 460HR 460SI 460SI 460SI 460S1 460S1 460SI 460S1 460S1 460HR 460HR 460HR 460S1 460SI 460SI 460S1 460HR 460SI 460S1 460HR 460SI 460HR 460SI 460S1 460S1 460HR 460HR 460S1 3S0EX 3S0EX 460S1 460S1 460S1 460HR 460S1 460S1 460S1 460HR 460S1

Framatome ANP Inc.

Customer Name: Oconee unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS ~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION 123 6 123 7 123 8 123 9 123 12 123 13 123 14 123 15 123 16 123 22 123 23 123 24 123 32 123 33 123 39 123 48 123 60 123 64 123 68 123 70 123 71 123 80 123 83 123 88 123 90 123 91 123 92 123 95 123 96 123 97 123 98 123 101 123 102 123 103 123 104 124 1 0.31 0.39 2.11 2.11 0.33 0.50 4.10 7.94

1. 95 42.67 5.33 6.70 0.94 0.54 6.38 3.84 8.09 3.34 4.80 5.28
1. 77 5.14 7.26 5.04 5.23
1. 58 2.18 2.18
1. 35
1. 35 0.77 0.77 0.58 0.58
1. 58
1. 58 3.95 2.36 2.25 0.78 0.00 0.21 0.33 0.39 0.27 0.35 0.00 1.17 1.22 1.15 0.70 0.70 5.16 4.80 7.81 2.79 2.74 2.33 8.11
1. 99 5.11 3.46 0.37 0.50 0.75 3.30 5.17 0.45 2.01 4.81 3.47 0.44
1. 46 0.00 0.12 o o P 3 TWD 7 P 3 TWD 9 27 2

2 27 154 P 105 P 179 1 182 1 201 2 9

1 171 1 179 1 18 2

81 P

32 2

28 2

175 1 169 1 171 1 175 1 164 1 172 1 175 1 176 1 162 1 22 2

32 2

32 2

17 2

17 2

20 2

20 2

14 2

14 2

27 2

27 2

25 2

20 2

25 2

22 MAl TWD 80 3 TWD 7 3 TWD 11 o

170 2

11 9

11 o

20 26 DNT DNT TEA SCI DNT DNT TEA 3 TWD 12 P 1 P 3 P 3 P 3 P 3 P 3 P 3 P 3 2

2 TEA TEA DNT DNT DNT DNT DNT DNT DNT DNT DNT TEA MAl TWD 97 SAl TWD 43 SAl TWD 51 SAl TWD 35 SAl TWD 75 TEA TEA TEA SCI TWD 0 TWD 14 TWD TWD TWD TWD TWD TEA TEA 22 25 18 23 o

008 010 UTE UTE 010 010 LTE UTE UTE LTE LTE UTE UTE 008 UTE UTE LTE UTE LTE LTE UTE UTE LTE UTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 20 2

29 2

29 2

28 2

184 1 182 1 31 2

177 1 28 2

182 1 34 2

181 1 20 2

18 TEA UTE TWD 100 UTE 66 53 26 29 31 29 26 24 o

27 o

35 P 3 P 3 P 3 2

2 SAl TEA DNT DNT TEA DNT TEA DNT TEA DNT TEA TWD 8 TWD 10 TWD 15 TEA TEA P 3 TWD 9 2

2 2

P 3 P 1 P 3 P 3 TEA TEA TEA TWD 10 SCI TWD 0 TWD 7 UTE UTE UTE UTE UTE LTE UTE UTE UTE LTE UTE 008 008 009 UTE UTE 009 UTE UTE UTE 006 UTE UTE UTE

+0.29

+0.52

-3.50

-3.50

+0.47

+0.48

+11.04

-11. 73

-0.21

+2.83

+11.17

-11.90

-0.19

+0.72

-0.15

-0.13

+11. 43

-11. 80

+11. 94

+11.09

-11.11

-12.02

+11. 20

-11.86

+6.57

-0.27

-3.50

-3.50

-1. 54

-1. 54

-1. 73

-1. 73

-2.70

-2.70

-3.64

-3.64

-0.10

-0.12

-0.11

-0.45

-0.45

-0.45

-0.45

-0.45

-0.45

-0.45

-0.45

-0.25

-0.20

-0.25

-0.96

-0.96

-0.17

-8.76

-9.50

-0.17

+11. 30

-0.20

-9.81

-0.20

+11. 40

-0.13

+0.16

+0.29

-0.63

-0.18

-0.34

+0.69

-0.15

-0.32

-0.17

+0.80

-0.25

-0.25

-0.25 TO+155.6 TO+146.7 TO+137.8 TO+128.9 TO+120.0 TO+111.1 T0+102.2 TO+91.1 T0+100.3 05/02/02 13:30:39 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG 008 008 010 010 UTE UTS UTE UTS 010 010 010 010 LTE LTE UTE UTE UTE UTE LTE LTE LTE LTE UTE UTE UTE UTE 008 008 UTE UTE UTE UTE LTE LTE UTE UTE LTE LTE LTE LTE UTE UTE UTE UTE LTE LTE UTE UTE LTE LTE UTE UTE UTE UTS UTE UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE UTE UTE LTE LTE UTE UTE 008 008 008 008 009 009 UTE UTE UTE UTE 009 009 UTE UTE UTE UTE UTE UTE 006 006 UTE UTS UTE UTS UTE UTS WAR WAR WAR WAR WAR CS CS CS CL/CS CS WAR WAR WAR WAR WAR CL 4056 4056 2092 2092 4056 4056 4056 4056 2093 708 4056 4056 2092 4056 2092 2093 4060 4060 4060 4060 4060 4060 4060 4060 4061 2092 2092 2092 2093 2093 2093 2093 2093 2093 2054 2054 2054 2054 2054 2054 2054 2054 2054 2054 2054 2054 2054 2053 2054 2051 2052 2052 2051 4026 4026 4026 4026 2051 4026 4026 4026 2052 4026 4026 4026 2054 2053 4026 2054 2053 2054 4056 2092 2092 2092 OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET Page 129 of 155 PROBE 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460HR 380EX 460SI 460SI 460HR 460SI 460HR 460HR 460SI 460SI 460SI 460S1 460S1 460SI 460SI 460S1 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460HR 460S1 460SI 460SI 460HR 460SI 460SI 460SI 460HR 460HR 460SI 460HR 460HR 460HR 460S1 460HR 460HR 460HR

Framatome ANP Inc.

05/02/02 13:30:40 Customer Name: Oconee Unit 1 Component: S/G B Page 130 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

0.27 21 P 3 TWO 11 UTE

-0.25 TO+109.4 UTE UTS 2092 INLET 460HR 0.60 17 P 3 TWO 22 UTE

-0.25 TO+118.5 UTE UTS 2092 INLET 460HR 0.97 16 P 3 TWO 38 UTE

-0.25 TO+127.6 UTE UTS 2092 INLET 460HR 1.12 14 P 3 TWO 45 UTE

-0.25 TO+136.7 UTE UTS 2092 INLET 460HR 0.89 14 P 3 TWO 34 UTE

-0.25 TO+145.8 UTE UTS 2092 INLET 460HR 0.51 15 P 3 TWO 19 UTE

-0.25 TO+154.9 UTE UTS 2092 INLET 460HR 0.28 31 P 3 TWO 11 UTE

-0.25 TO+164.1 UTE UTS 2092 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.25 TO+173.2 UTE UTS 2092 INLET 460HR 124 2 3.87 23 2

TEA UTE

-0.17 UTE UTE 2093 INLET 460HR 124 3 0.08 82 2

VOL 013

+1. 44 013 013 4056 OUTLET 460S1 1.82 179 1 ONT UTE

-7.62 UTE UTE 4056 OUTLET 460S1 124 6 0.29 71 2

VOL 004

+0.72 004 004 4056 OUTLET 460S1 0.35 104 P 3 TWO 9 009

-0.74 009 009 WAR 4056 OUTLET 460SI 1.54 35 2

MAl UTE

-3.50 UTE UTS 2092 INLET 460HR

1. 55 33 2

TWO 100 UTE

-3.50 UTE UTS 2092 INLET 460HR 124 7 2.65 23 2

TEA UTE

-0.21 UTE UTE 2093 INLET 460HR 124 8 0.36 0

P 3 TWO 8 010

+0.28 010 010 WAR 4056 OUTLET 460S1 6.97 29 2

TEA UTE

-0.21 UTE UTE 2092 INLET 460HR 124 9 0.51 0

P 3 TWO 11 009

-0.37 009 009 WAR 4056 OUTLET 460S1 5.37 22 2

TEA UTE

-0.17 UTE UTE 2093 INLET 460HR 124 10

1. 98 27 2

TEA UTE

-0.22 UTE UTE 2092 INLET 460HR 124 13

1. 63 25 2

TEA UTE

-0.27 UTE UTE 2092 INLET 460HR 124 14 0.08 49 2

VOL 014

+1.21 014 014 4056 OUTLET 460S1 3.32 26 2

TEA UTE

-0.10 UTE UTE 2093 INLET 460HR 124 18 0.56 141 P 3 TWO 13 009

-0.77 009 009 WAR 4060 OUTLET 460S1 124 20 6.66 178 1 ONT LTE

+11.28 LTE LTE 4060 OUTLET 460S1 9.17 179 1 ONT UTE

-11. 61 UTE UTE 4060 OUTLET 460S1 124 23 6.78 167 1 ONT LTE

+11. 05 LTE LTE 4060 OUTLET 460S1 7.11 174 1 ONT UTE

-12.12 UTE UTE 4060 OUTLET 460S1 124 24 3.07 24 2

TEA UTE

-0.19 UTE UTE 2093 INLET 460HR 124 25 0.87 19 2

SAl UTE

-3.48 UTE UTS 2125 INLET 460HR 0.88 19 2

TWO 51 UTE

-3.48 UTE UTS 2125 INLET 460HR 124 28

1. 61 24 2

TEA UTE

-0.17 UTE UTE 2093 INLET 460HR 124 32 6.57 29 2

TEA UTE

-0.24 UTE UTE 2092 INLET 460HR 124 41 2.13 24 2

TEA UTE

-0.18 UTE UTE 2093 INLET 460HR 124 48 0.27 33 2

SVI UTE

-3.55 UTE UTS 2092 INLET 460HR 0.27 33 2

TWO 100 UTE

-3.55 UTE UTS 2092 INLET 460HR 124 50 0.90 27 2

SAl UTE

-1.13 UTE UTE TR 2092 INLET 460HR 0.90 27 2

TWO 80 UTE

-1.13 UTE UTE 2092 INLET 460HR 124 53 7.78 180 1 ONT 006

-5.22 006 006 4015 INLET 460SI 124 61 7.30 27 2

TEA UTE

-0.13 UTE UTE 2054 INLET 460HR 124 62 2.22 35 2

TEA UTE

-0.25 UTE UTE 2053 INLET 460HR 124 64 2.68 29 2

TEA UTE

-0.23 UTE UTE 2053 INLET 460HR 124 74 0.50 97 P 3 TWO 11 013

-0.79 013 013 WAR 4085 OUTLET 460S1 124 75 0.08 78 2

VOL 010

+1.03 010 010 4023 INLET 460S1 124 79 0.89 17 2

TWO 51 UTE

-1.19 UTE UTE 2054 INLET 460HR 0.89 17 2

SAl UTE

-1.19 UTE UTE TR 2054 INLET 460HR 124 90 1.24 22 2

TEA UTE

-0.47 UTE UTE 2053 INLET 460HR 124 92 3.48 30 2

TEA UTE

-0.44 UTE UTE 2053 INLET 460HR 124 93 2.69 25 2

TEA UTE

-0.20 UTE UTE 2054 INLET 460HR 124 96 4.75 28 2

TEA UTE

-0.43 UTE UTE 2053 INLET 460HR 124 97 4.31 29 2

TEA UTE

-0.41 UTE UTE 2053 INLET 460HR 0.79 126 P 3 TWO 16 010

+0.79 010 010 WAR 4026 INLET 460SI 9.18 172 1 ONT 009

+0.21 009 009 4026 INLET 460SI 124 98 3.01 25 2

TEA UTE

-0.14 UTE UTE 2054 INLET 460HR 124 99 4.46 32 2

TEA UTE

-0.38 UTE UTE 2053 INLET 460HR 124 100 0.86 30 2

TEA UTE

-0.09 UTE UTE 2054 INLET 460HR 125 1 1.17 26 2

MAl UTE

-3.52 UTE UTS 2092 INLET 460HR 1.17 26 2

TWO 77 UTE

-3.52 UTE UTS 2092 INLET 460HR 125 3 0.24 0

P 3 TWO 5 014

+0.63 014 014 WAR 4056 OUTLET 460SI 3.31 28 2

TEA UTE

-0.22 UTE UTE 2092 INLET 460HR 125 5 0.24 67 2

VOL 004

+1.25 004 004 4056 OUTLET 460SI 0.08 51 2

VOL 012

+1.19 012 012 4056 OUTLET 460S1 4.34 27 2

TEA UTE

-0.16 UTE UTE 2092 INLET 460HR 125 6 3.47 26 2

TEA UTE

-0.17 UTE UTE 2093 INLET 460HR 125 8 0.75 13 P 1 SCI UTE

-0.95 UTE UTE CS 2092 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.95 TO+4.6 UTE UTE 2092 INLET 460HR 0.63 18 p 3 TWO 36 UTE

-0.95 TO+355.4 UTE UTE 2092 INLET 460HR 0.75 13 P 3 TWO 42 UTE

-0.95 TO+346.3 UTE UTE 2092 INLET 460HR 0.67 17 P 3 TWO 38 UTE

-0.95 TO+337.2 UTE UTE 2092 INLET 460HR 0.49 21 P 3 TWO 28 UTE

-0.95 TO+328.1 UTE UTE 2092 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.95 TO+319.0 UTE UTE 2092 INLET 460HR 125 9 0.45 0

P 3 TWO 10 008

-0.52 008 008 WAR 4056 OUTLET 460S1 1.04 0

P 3 TWO 21 009

-0.71 009 009 WAR 4056 OUTLET 460S1 125 10

1. 09 0

P 3 TWO 22 009

-0.74 009 009 WAR 4056 OUTLET 460SI

Framatome ANP Inc.

05/02/02 13:30:42 Customer Name: Oconee Unit 1 Component: S/G B Page 131 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMI ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

===================
===

125 12 3.45 16 2

TEA UTE

-0.21 UTE UTE 2093 INLET 460HR 125 19 0.27 150 P 3 TWO 7 009

-0.66 009 009 WAR 4060 OUTLET 460SI

1. 74 174 1 ONT 010

+17.71 010 010 4060 OUTLET 460SI 125 20 3.04 177 1 DNT LTE

+11. 29 LTE LTE 4060 OUTLET 460SI 1.21 168 1 ONT UTE

-10.83 UTE UTE 4060 OUTLET 460SI 7.66 179 1 ONT UTE

-11.57 UTE UTE 4060 OUTLET 460SI 125 21 3.92 174 1 ONT LTE

+10.79 LTE LTE 4060 OUTLET 460SI 3.15 183 1 ONT UTE

-11.54 UTE UTE 4060 OUTLET 460SI 5.19 186 1 DNT UTE

-11.76 UTE UTE 4060 OUTLET 460SI 7.37 24 2

TEA UTE

-0.23 UTE UTE 2092 INLET 460HR 1.12 27 2

MAl UTE

-1.15 UTE UTE TR 2092 INLET 460HR 1.12 27 2

TWO 80 UTE

-1.15 UTE UTE 2092 INLET 460HR 125 22 7.45 179 1 ONT LTE

+10.90 LTE LTE 4060 OUTLET 460SI 1.36 169 1 DNT LTE

+10.32 LTE LTE 4060 OUTLET 460SI 0.30 68 P 3 TWO 7 009

-0.64 009 009 WAR 4060 OUTLET 460S1 7.51 178 1 ONT UTE

-11. 80 UTE UTE 4060 OUTLET 460S1 0.92 26 2

MAl UTE

-3.48 UTE UTS 2093 INLET 460HR 0.92 23 2

TWO 60 UTE

-3.48 UTE UTS 2093 INLET 460HR 125 25 3.28 24 2

TEA UTE

-0.21 UTE UTE 2092 INLET 460HR 125 28 0.35 73 P 3 TWO 8 009

-0.65 009 009 WAR 4060 OUTLET 460S1 125 30 2.31 25 2

TEA UTE

-0.18 UTE UTE 2093 INLET 460HR 125 43 0.15 34 2

VOL UTE

-2.56 UTE UTE 2092 INLET 460HR 0.27 30 2

SVI UTE

-1.02 UTE UTE CS 2092 INLET 460HR 0.27 30 2

TWO 90 UTE

-1.02 UTE UTE 2092 INLET 460HR 0.59 33 P 1 SCI UTE

-1.10 UTE UTE TR 2092 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-1.10 TO+227.8 UTE UTE 2092 INLET 460HR 0.37 44 P 3 TWD 66 UTE

-1.10 TO+218.7 UTE UTE 2092 INLET 460HR 0.53 37 P 3 TWO 82 UTE

-1.10 TO+209.6 UTE UTE 2092 INLET 460HR 0.56 38 P 3 TWO 85 UTE

-1.10 TO+200.5 UTE UTE 2092 INLET 460HR 0.51 45 P 3 TWO 80 UTE

-1.10 TO+191. 4 UTE UTE 2092 INLET 460HR 0.24 68 P 3 TWO 48 UTE

-1.10 TO+182.3 UTE UTE 2092 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-1.10 TO+173.2 UTE UTE 2092 INLET 460HR 125 47 6.75 29 2

TEA UTE

-0.13 UTE UTE 2092 INLET 460HR 125 49 2.77 24 2

TEA UTE

-0.15 UTE UTE 2092 INLET 460HR 125 50 7.51 23 2

TEA UTE

-0.23 UTE UTE 2093 INLET 460HR 125 51 3.86 30 2

TEA UTE

-0.19 UTE UTE 2053 INLET 460HR 6.00 31 2

TEA UTE

-0.16 UTE UTE 4015 INLET 460S1 125 52

1. 94 30 2

SAl UTE

-3.60 UTE UTS 2054 INLET 460HR

1. 94 30 2

TWD 81 UTE

-3.60 UTE UTS 2054 INLET 460HR 125 55 5.40 178 1 ONT 009

+15.13 009 009 4015 INLET 460S1 125 56 0.41 70 2

VOL 007

+0.89 007 007 4015 INLET 460S1 125 57 3.90 187 1 DNT LTS

+10.37 LTS LTS 4015 INLET 460S1 125 60 3.67 29 2

TEA UTE

-0.15 UTE UTE 2054 INLET 460HR 125 63 3.53 29 2

TEA UTE

-0.24 UTE UTE 2053 INLET 460HR 125 65 2.62 25 2

TEA UTE

-0.22 UTE UTE 2053 INLET 460HR 125 66 2.77 21 2

TEA UTE

-0.11 UTE UTE 2054 INLET 460HR 125 71 3.98 28 2

TEA UTE

-0.16 UTE UTE 2053 INLET 460HR 125 73 1.52 19 2

TEA UTE

-0.34 UTE UTE 2053 INLET 460HR 125 74 3.79 29 2

TEA UTE

-0.10 UTE UTE 2054 INLET 460HR 125 78 4.80 30 2

TEA UTE

-0.14 UTE UTE 2054 INLET 460HR 125 79 0.92 22 2

MAl UTE

-3.66 UTE UTS 2053 INLET 460HR 0.92 22 2

TWO 64 UTE

-3.66 UTE UTS 2053 INLET 460HR 125 83 0.82 31 2

TEA UTE

-0.17 UTE UTE 2053 INLET 460HR 125 84 1.59 33 2

TEA UTE

-0.12 UTE UTE 2054 INLET 460HR 125 87 0.80 24 2

SAl UTE

-3.41 UTE UTS 2053 INLET 460HR 0.80 24 2

TWO 70 UTE

-3.41 UTE UTS 2053 INLET 460HR 125 89 0.84 25 2

TEA UTE

-0.29 UTE UTE 2053 INLET 460HR 125 92 7.51 28 2

TEA UTE

-0.13 UTE UTE 2054 INLET 460HR 0.29 69 P 3 TWO 6 009

+0.69 009 009 WAR 4026 INLET 460S1 0.30 111 P 3 TWO 6 009

-0.74 009 009 WAR 4026 INLET 460S1 125 94 3.88 30 2

TEA UTE

-0.34 UTE UTE 2053 INLET 460HR 125 95 1.11 121 P 3 TWO 21 010

+0.68 010 010 WAR 4026 INLET 460S1 13.48 180 1 ONT 009

-0.02 009 009 4026 INLET 460S1 125 96 0.68 70 P 3 TWD 14 010

-0.59 010 010 WAR 4026 INLET 460S1 125 97

1. 73 26 2

TEA UTE

-0.10 UTE UTE 2054 INLET 460HR 125 98 2.27 25 2

TEA UTE

-0.32 UTE UTE 2053 INLET 460HR 0.31 28 P 3 TWO 6 009

+0.66 009 009 WAR 4026 INLET 460S1 125 100 3.75 24 2

TEA UTE

-0.20 UTE UTE 2054 INLET 460HR 126 2

1. 42 15 P 1 SCI UTE

-0.41 UTE UTE CL/CS 2092 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.41 TO+209.6 UTE UTE 2092 INLET 460HR 0.30 49 P 3 TWO 26 UTE

-0.41 TO+218.7 UTE UTE 2092 INLET 460HR 0.47 54 P 3 TWO 47 UTE

-0.41 TO+227.8 UTE UTE 2092 INLET 460HR 0.72 44 P 3 TWO 95 UTE

-0.41 TO+237.0 UTE UTE 2092 INLET 460HR 0.51 47 P 3 TWO 53 UTE

-0.41 TO+246.1 UTE UTE 2092 INLET 460HR 0.39 44 P 3 TWO 36 UTE

-0.41 TO+255.2 UTE UTE 2092 INLET 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS - MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION 126 6 126 8 126 13 126 15 126 17 126 23 126 24 126 25 126 28 126 31 126 32 126 37 126 40 126 42 126 44 126 45 126 46 126 47 126 48 126 50 126 52 126 53 126 55 126 56 126 58 126 59 126 60 126 61 126 63 126 64 126 65 126 68 126 69 126 73 126 79 126 81 126 83 126 84 126 85 126 90 126 91 126 94 126 97 126 98 126 99 127 2 127 5 127 6 127 7 127 10 127 12 127 16 127 17 127 19 0.00 2.03 0.50 0.45 0.83 0.26 0.20 0.31 0.40 0.24 1.20 1.20 1.24 5.06 2.33

1. 41
1. 46 2.79 1.92 0.72 0.72 2.31 1.95 0.41 0.41 0.62 0.62 2.15 6.52 0.76 0.76 0.55 0.49 0.49 0.33
1. 94 4.09 1.07
1. 07 1.12 2.07 2.07 1.66 0.78 0.72 2.41 1.23 1.36 1.15 2.94 2.57 3.39 2.92 1.49 1.59 5.99 1.41 0.27 15.82 5.53
1. 71 0.24 2.45 0.19 5.23 0.17 2.36 0.53 1.15 0.37 0.26 1.82 3.36 3.57 0.29 o

P 3 TWO 0 UTE 23 2

TEA UTE 89 P 3 TWO 12 009 o

P 3 TWO 10 009 o

P 3 TWO 18 008 137 P 3 TWO 6 008 53 2

VOL 015 121 P 3 TWD 7 009 46 P 3 TWD 9 009 27 P 3 TWD 6 010 15 2

SAl UTE 18 2

TWO 46 UTE 37 2

TEA UTE 28 2

TEA UTE 29 2

TEA UTE 22 2

TEA UTE 27 2

TEA UTE 25 2

TEA UTE 30 2

TEA UTE 18 P 1 SVI UTE 18 P 1 TWO 51 UTE 29 2

TEA UTE 38 2

TEA UTE 18 P 1 SVI UTE 18 P 1 TWD 51 UTE 20 2

MAl UTE 20 2

TWD 51 UTE 31 2

TEA UTE 29 2

TEA UTE 27 2

MAl UTE 27 2

TWD 81 UTE 25 2

TEA UTE 28 2

SAl UTE 28 2

TWD 77 UTE 127 2 VOL 007 20 2

TEA UTE 26 2

TEA UTE 29 2

SAl UTE 29 2

TWO 89 UTE 31 2

SAl UTE 26 2

SAl UTE 26 2

TWD 73 UTE 20 2

TEA UTE 51 P 3 TWO 11 008 27 2

TEA UTE 16 2

TEA UTE 24 2

TEA UTE 107 P 3 TWO 18 009 19 2

TEA UTE 23 2

TEA UTE 23 2

TEA UTE 23 2

TEA UTE 28 2

TEA UTE 28 2

TEA UTE 21 2

TEA UTE 33 2

TEA UTE 21 2

TEA UTE 22 P 3 TWO 6 009 186 1 DNT 009 21 2

TEA UTE 31 2

TEA UTE 75 2

VOL 003 26 2

TEA UTE 70 2

VOL 003 181 1 DNT 014 60 2

VOL 007 205 2 TEA UTE 114 P 3 TWO 12 008 23 2

TEA UTE 77 2

VOL 002 51 P 3 TWO 6 009 37 2

TEA UTE 31 2

TEA UTE 31 2

TEA UTE 69 P 3 TWD 7 007

-0.41 TO+264.3

-0.33

-0.53

+0.29

-0.53

+0.58

-0.74

-0.74

-0.67

-0.71

-1.10

-1.10

-0.33

-0.24

-0.40

-0.29

-0.20

-0.29

-0.22

-0.79

-0.79

-0.20

-0.22

-0.89

-0.89

-3.50

-3.50

-0.14

-0.13

-3.38

-3.38

-0.14

-3.76

-3.76

+0.73

-0.38

-0.20

-3.56

-3.56

-3.56

-3.67

-3.67

-0.12

+0.68

-0.15

-0.17

-0.36

+0.69

-0.17

-0.15

-0.13

-0.16

-0.10

-0.43

-0.17

-0.26

-0.17

-0.69

+0.33

-0.15

-0.40

+1.18

-0.13

+1.12

+7.87

+1. 31

-0.17

+0.34

-0.28

+0.79

-0.68

-0.28

-0.25

-0.22

-0.69 05/02/02 13:30:44 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE 009 009 WAR 009 009 WAR 008 008 WAR 008 008 WAR 015 015 009 009 WAR 009 009 WAR 010 010 WAR UTE UTE TR UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE CS UTE UTE UTE UTE UTE UTE UTE UTE CS UTE UTE UTE UTS UTE UTS UTE UTE UTE UTE UTE UTS UTE UTS UTE UTE UTE UTS UTE UTS 007 007 UTE UTE UTE UTE UTE UTS UTE UTS UTE UTE UTE UTS UTE UTS UTE UTE 008 008 WAR UTE UTE UTE UTE UTE UTE 009 009 WAR UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 009 WAR 009 009 UTE UTE UTE UTE 003 003 UTE UTE 003 003 014 014 007 007 UTE UTE 008 008 WAR UTE UTE 002 002 009 009 WAR UTE UTE UTE UTE UTE UTE 007 007 WAR 2092 2092 4056 4056 4056 4056 4056 4060 4060 4060 2093 2093 2092 2093 2092 2093 2092 2092 2092 2092 2092 2093 2092 2092 2092 2093 2093 2092 2092 2053 2053 2054 2054 2054 4015 2053 2054 2053 2053 4015 2054 2054 2054 4015 2053 2054 2053 4015 2054 2054 2054 2054 2054 2053 2054 2053 2054 4026 4026 2054 2053 4026 2054 4026 4057 4057 2093 4057 2092 4057 4057 2092 2092 2093 4060 INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET INLET OUTLET OUTLET INLET INLET INLET OUTLET Page 132 of 155 PROBE 460HR 460HR 460SI 460SI 460SI 460S1 460S1 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460HR 460HR 460S1 460HR 460S1 460SI 460SI 460HR 460SI 460HR 460S1 460SI 460HR 460HR 460HR 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION 127 26 127 27 127 31 127 33 127 46 127 50 127 53 127 55 127 58 127 60 127 61 127 64 127 68 127 69 127 73 127 74 127 79 127 87 127 88 127 91 127 92 127 93 127 94 127 96 127 98 128 2 128 5 128 6 128 7 128 9 128 14 128 16 128 17 128 18 128 19 128 21 128 22 128 25 128 27 128 28 128 32 128 38 128 44 128 50 128 54 0.74 0.74 0.40 0.81 3.58 0.82 0.82

1. 96 2.24 5.55 2.23 2.87 4.34 0.77 3.21 0.38 0.38 0.97 0.97 1.18 1.18 1.17 0.83 0.83 0.31 0.00 0.14 0.24 0.22 0.17 0.12 0.10 0.00 0.66 0.66 0.24 6.33 3.11 6.12 8.01 0.68 2.89 3.45 0.32 0.32 0.23 0.13 2.51 5.38 0.46 0.72 0.39 0.12 0.25 0.45 0.61 0.23 0.24 0.90 0.90
1. 95
1. 30 2.90 3.69 2.08 2.34 0.27 0.30 0.50 0.50 0.13 0.17 0.28 0.41 0.48 18 18 2

2 SAl TWO 51 3 TWO 9 3 TWO 17 TEA SAl TWO 63 TEA TEA TEA TEA TEA TEA 72 P

130 P 21 2

21 2

21 2

17 2

22 2

21 2

25 2

29 2

22 2

77 P 3 TWO 11 2

TEA 32 43 43 36 36 22 22 27 23 23 37 o

46 45 47 49 52 56 o

18 18 164 31 31 30 181 29 25 25 37 74 55 97 33 28 35 44 32 29 24 43 76 155 93 13 13 24 17 27 26 24 24 84 34 30 30 50 51 45 42 36 2

2 2

2 2

2 2

2 2

TWO 96 SVI SAl TWO 93 TWO 64 SAl TEA MAl TWO 67 P 1 SCI P 3 TWO 0 P 3 TWO 61 P 3 TWO 94 P 3 TWO 90 P 3 TWO 72 P 3 TWO 50 P 3 TWO 44 P 3 TWO 0 2

SAl 2

TWO 50 P 3 TWO 3 2

2 2

1 2

2 2

TEA TEA TEA ONT TEA TEA TEA P 3 TWO 6 2

VOL 2

2 2

2 2

2 P 3 P 3 P 3 P 3 P 3 P 3 P 4 2

2 2

2 2

2 2

2 2

VOL VOL TEA TEA VOL TEA TWO 9 TWO 3 TWO 6 TWO 10 TWO 14 TWO 5 TWO 6 SAl TWO 32 TEA TEA TEA TEA TEA TEA VOL P 1 SCI 2

SAl 2

TWO 92 P 3 P 3 P 3 P 3 P 3 TWO TWO TWO TWo TWO o

53 68 83 90 UTE UTE 009 009 UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 UTE UTE UTE 009 UTE UTE UTE 011 003 001 007 UTE UTE 015 UTE 009 007 009 008 009 009 009 UTE UTE UTE UTE UTE UTE UTE UTE 011 UTE UTE UTE UTE UTE UTE UTE UTE

-1.15

-1.15

-0.66

-0.64

-0.18

-1.13

-1.13

-0.16

-0.17

-0.17

-0.29

-0.22

-0.13

+0.70

-0.15

-0.78

-0.78

-3.50

-3.50

-1.19

-1.19

-0.25

-3.74

-3.74

-1. 20

-1. 20

-1. 20

-1. 20

-1. 20

-1. 20

-1. 20

-1. 20

-1. 20

-0.93

-0.93

+0.70

-0.39

-0.18

-0.30

+0.43

-0.18

-0.32

-0.13

-0.34

+0.93

+1.02

+1. 02

-0.27

-0.17

-0.78

-0.21

-0.76

-0.67

-0.69

+0.64

-0.66

+0.65

-0.69

-1.13

-1.13

-0.24

-0.32

-0.22

-0.22

-0.22

-0.24

+1.11

-1. 27

-3.49

-3.49

-1. 27

-1. 27

-1.27

-1. 27

-1. 27 TO+219.6 TO+228.4 TO+237.2 TO+246.0 TO+254.7 TO+263.5 TO+272.3 TO+281.1 TO+93.3 TO+84.4 TO+75.6 TO+66.7 TO+57.8 05/02/02 13:30:45 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE 009 009 009 009 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 009 UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE UTE UTE 009 009 UTE UTE UTE UTE UTE UTE 009 009 UTE UTE UTE UTE UTE UTE 011 011 003 003 001 001 007 007 UTE UTE UTE UTE 015 015 UTE UTE 009 009 007 007 009 009 008 008 009 009 009 009 009 009 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 011 011 UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS TR WAR WAR TR WAR CS TR TR CS WAR WAR WAR WAR WAR WAR WAR WAR WAR TR TR 2092 2092 4060 4065 2093 2092 2092 2053 2054 2054 2053 2053 2054 4015 2053 2053 2053 2054 2054 2053 2053 2054 2053 2053 2053 2053 2053 2053 2053 2053 2053 2053 2053 2053 2053 4026 2053 2054 2053 4026 2054 2053 2054 4026 4026 4057 4057 2092 2093 4057 2092 4057 4057 4057 4057 4057 4065 4065 2093 2093 2092 2092 2093 2093 2092 2092 4015 2053 2053 2053 2053 2053 2053 2053 2053 INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 133 of 155 PROBE 460HR 460HR 460S1 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460S1 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460HR 460HR 460S1 460HR 460S1 460S1 460S1 460S1 460S1 460S1 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR

Framatome ANP Inc.

05/02/02 13:30:47 Customer Name: Oconee unit 1 Component: S/G B Page 134 of 155 ATTACHMENT 114 -

LIST OF IMPERFECTIONS - MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL II LEG PROBE

============
===

0.33 41 P 3 TWO 74 UTE

-1. 27 TO+48.9 UTE UTS 2053 INLET 460HR 0.17 49 P 3 TWO 0 UTE

-1.27 TO+40.0 UTE UTS 2053 INLET 460HR 0.79 29 P 1 SCI UTE

-3.66 UTE UTS TR 2053 INLET 460HR 0.17 128 P 3 TWO 0 UTE

-3.66 To+17.8 UTE UTS 2053 INLET 460HR 0.17 154 P 3 TWO 49 UTE

-3.66 TO+8.9 UTE UTS 2053 INLET 460HR 0.19 62 P 3 TWO 52 UTE

-3.66 TO+O.O UTE UTS 2053 INLET 460HR 0.23 48 P 3 TWO 57 UTE

-3.66 TO+351.1 UTE UTS 2053 INLET 460HR 0.29 46 P 3 TWO 63 UTE

-3.66 TO+342.2 UTE UTS 2053 INLET 460HR 0.29 47 P 3 TWO 64 UTE

-3.66 TO+333.3 UTE UTS 2053 INLET 460HR 0.23 58 P 3 TWO 56 UTE

-3.66 TO+324.4 UTE UTS 2053 INLET 460HR 0.18 66 P 3 TWO 50 UTE

-3.66 TO+315.6 UTE UTS 2053 INLET 460HR 0.11 89 P 3 TWO 40 UTE

-3.66 TO+306.7 UTE UTS 2053 INLET 460HR 0.16 168 P 3 TWO 47 UTE

-3.66 TO+297.8 UTE UTS 2053 INLET 460HR 0.15 18 P 3 TWO 45 UTE

-3.66 TO+288.9 UTE UTS 2053 INLET 460HR 0.18 51 P 3 TWO 50 UTE

-3.66 TO+280.0 UTE UTS 2053 INLET 460HR 0.24 46 P 3 TWO 58 UTE

-3.66 TO+27l.1 UTE UTS 2053 INLET 460HR 0.29 44 P 3 TWO 63 UTE

-3.66 TO+262.2 UTE UTS 2053 INLET 460HR 0.35 39 P 3 TWO 70 UTE

-3.66 TO+253.3 UTE UTS 2053 INLET 460HR 0.41 37 P 3 TWO 75 UTE

-3.66 TO+244.4 UTE UTS 2053 INLET 460HR 0.40 37 P 3 TWO 74 UTE

-3.66 TO+235.6 UTE UTS 2053 INLET 460HR 0.39 35 P 3 TWO 73 UTE

-3.66 TO+226.7 UTE UTS 2053 INLET 460HR 0.37 39 P 3 TWO 71 UTE

-3.66 TO+217.8 UTE UTS 2053 INLET 460HR 0.40 39 P 3 TWO 74 UTE

-3.66 TO+208.9 UTE UTS 2053 INLET 460HR 0.39 43 P 3 TWO 73 UTE

-3.66 TO+200.0 UTE UTS 2053 INLET 460HR 0.34 51 P 3 TWO 68 UTE

-3.66 TO+191.1 UTE UTS 2053 INLET 460HR 0.48 40 P 3 TWO 81 UTE

-3.66 TO+182.2 UTE UTS 2053 INLET 460HR 0.67 31 P 3 TWO 96 UTE

-3.66 TO+173.3 UTE UTS 2053 INLET 460HR 0.58 37 P 3 TWO 89 UTE

-3.66 TO+l64.4 UTE UTS 2053 INLET 460HR 0.56 41 P 3 TWO 88 UTE

-3.66 TO+155.6 UTE UTS 2053 INLET 460HR 0.44 42 P 3 TWO 78 UTE

-3.66 TO+146.7 UTE UTS 2053 INLET 460HR 0.16 63 P 3 TWO 47 UTE

-3.66 TO+137.8 UTE UTS 2053 INLET 460HR 0.13 103 P 3 TWO 0 UTE

-3.66 TO+128.3 UTE UTS 2053 INLET 460HR 128 55 0.29 91 2

VOL 007

+0.85 007 007 4015 INLET 460S1 128 58 1.02 21 2

TEA UTE

-0.32 UTE UTE 2053 INLET 460HR 128 59 2.63 26 2

TEA UTE

-0.25 UTE UTE 2054 INLET 460HR 128 60 4.72 28 2

TEA UTE

-0.30 UTE UTE 2053 INLET 460HR 128 61 6.18 25 2

TEA UTE

-0.21 UTE UTE 2054 INLET 460HR 128 62 5.29 32 2

TEA UTE

-0.21 UTE UTE 2053 INLET 460HR 128 64 3.12 28 2

TEA UTE

-0.32 UTE UTE 2053 INLET 460HR 128 65 5.66 28 2

TEA UTE

-0.21 UTE UTE 2054 INLET 460HR 128 66 0.54 17 2

SAl UTE

-3.47 UTE UTS 2053 INLET 460HR 0.54 17 2

TWO 47 UTE

-3.47 UTE UTS 2053 INLET 460HR 128 67 4.71 23 2

TEA UTE

-0.20 UTE UTE 2054 INLET 460HR 128 68

1. 58 26 2

SAl UTE

-3.51 UTE UTS 2053 INLET 460HR

1. 58 26 2

TWO 78 UTE

-3.51 UTE UTS 2053 INLET 460HR 128 70 0.62 27 p 1 MCI UTE

-3.7l UTE UTS 2053 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.7l TO+114.1 UTE UTS 2053 INLET 460HR 0.31 152 P 3 TWO 66 UTE

-3.7l TO+122.9 UTE UTS 2053 INLET 460HR 0.29 41 P 3 TWO 62 UTE

-3.71 TO+131. 7 UTE UTS 2053 INLET 460HR 0.36 46 P 3 TWO 78 UTE

-3.71 TO+140.5 UTE UTS 2053 INLET 460HR 0.33 50 P 3 TWO 70 UTE

-3.71 TO+149.3 UTE UTS 2053 INLET 460HR 0.24 51 P 3 TWO 52 UTE

-3.71 TO+158.0 UTE UTS 2053 INLET 460HR 0.15 70 P 3 TWO 32 UTE

-3.71 TO+166.8 UTE UTS 2053 INLET 460HR 0.14 128 P 3 TWO 31 UTE

-3.71 TO+175.6 UTE UTS 2053 INLET 460HR 0.22 159 P 3 TWO 47 UTE

-3.7l TO+184.4 UTE UTS 2053 INLET 460HR 0.31 167 P 3 TWO 66 UTE

-3.7l TO+193.2 UTE UTS 2053 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.7l TO+202.0 UTE UTS 2053 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.7l TO+206.4 UTE UTS 2053 INLET 460HR 0.16 126 P 3 TWO 34 UTE

-3.7l TO+215.2 UTE UTS 2053 INLET 460HR 0.25 52 P 3 TWO 53 UTE

-3.7l TO+224.0 UTE UTS 2053 INLET 460HR 0.25 50 P 3 TWO 53 UTE

-3.71 TO+232.8 UTE UTS 2053 INLET 460HR 0.22 178 P 3 TWO 48 UTE

-3.71 TO+241. 6 UTE UTS 2053 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.71 TO+250.3 UTE UTS 2053 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.71 TO+254.6 UTE UTS 2053 INLET 460HR 0.16 105 P 3 TWO 35 UTE

-3.71 TO+263.4 UTE UTS 2053 INLET 460HR 0.32 44 P 3 TWO 68 UTE

-3.71 TO+272.2 UTE UTS 2053 INLET 460HR 0.44 37 P 3 TWO 94 UTE

-3.7l TO+281. 0 UTE UTS 2053 INLET 460HR 0.42 39 P 3 TWO 90 UTE

-3.71 TO+289.8 UTE UTS 2053 INLET 460HR 0.36 43 P 3 TWO 78 UTE

-3.71 TO+298.5 UTE UTS 2053 INLET 460HR 0.36 48 P 3 TWO 76 UTE

-3.71 TO+307.3 UTE UTS 2053 INLET 460HR 0.26 58 P 3 TWO 55 UTE

-3.71 TO+316.1 UTE UTS 2053 INLET 460HR 0.24 134 P 3 TWO 50 UTE

-3.71 TO+324.9 UTE UTS 2053 INLET 460HR 0.31 0

P 3 TWO 66 UTE

-3.71 TO+333.7 UTE UTS 2053 INLET 460HR 0.34 0

P 3 TWO 72 UTE

-3.71 TO+342.4 UTE UTS 2053 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.71 TO+351.2 UTE UTS 2053 INLET 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS ~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 128 72 128 74 128 76 128 77 128 78 128 80 128 83 128 85 128 86 128 88 128 89 128 90 128 91 128 94 128 95 129 1 129 3 129 4 129 5 129 7 129 10 129 12 129 15 129 16 129 17 129 20 129 21 129 23 129 24 129 25 129 26 129 28 129 29 129 30 129 31 129 36 129 37 129 41 129 43 129 44 129 46 1.19 1.19 0.42 0.42 6.18 5.01

1. 05 1.05
1. 99 1.99 1.17 1.17 3.82 3.85 3.58 0.81 0.25 2.00 4.17 5.02 4.23 2.86 3.39 10.67 4.47
1. 56 0.36
1. 01
1. 85 2.92 0.34 0.55 0.63 0.11 0.17
1. 90 0.50 7.21 7.09 6.71 2.83 0.19 2.51 7.20 4.70 7.74
1. 94 5.92 4.61 1.29 6.47 10.03 0.18 0.37 0.36 0.10 3.76 5.17 0.63 6.28 4.14 3.76 0.94 0.51 0.00 0.33 0.44 0.72 0.84 0.74 0.61 0.53 0.54 0.50 0.00 13 13 14 14 28 30 31 31 29 29 13 13 28 27 SAl TWO 35 SAl TWO 38 TEA TEA SAl TWO 84 TWO 89 SAl SAl TWO 35 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

31 124 P 63 P

34 2

TEA TEA TEA 3 TWO 16 3 TWO 5 TEA ONT ONT ONT TEA ONT ONT TEA TEA 174 359 179 25 184 184 28 19 36 27 38 22 100 103 36 28 137 116 28 26 176 173 171 76 152 171 339 176 170 165 178 29 177 174 82 136 150 139 27 25 18 26 28 33 31 29 o

26 29 26 25 27 24 23 25 23 o

1 1

1 2

1 1

2 2

P 3 TWO 7 2

TEA 2

TEA 2

TEA P 3 TWO 8 P 3 TWO 13 P 3 TWO 14 2

VOL P 3 TWO 4 1

VOL P 3 TWO 12 2

TEA 1

ONT 1

ONT 1

ONT 2

VOL 1

ONT 1

ONT 1

ONT 1

ONT 1

ONT 1

ONT 1

ONT 2

TEA 1

ONT 1

ONT P 4 TWO 4 P 3 TWO 8 P 3 TWO 8 2

VOL 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA P 1 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 MCI TWO 0 18 28 59 77 62 45 36 37 33 o

TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 009 UTE LTE UTE UTE UTE UTE LTE UTE UTE 011 UTE UTE UTE 010 007 009 014 007 009 015 UTE UTE LTS LTS 013 UTE LTE LTE UTE LTE LTE UTE UTE LTS UTE 009 008 009 015 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE

-1.22

-1.22

-1.14

-1.14

-0.41

-0.35

-3.35

-3.35

-3.52

-3.52

-1.19

-1.19

-0.19

-0.19

-0.38

-0.69

+0.66

-0.19

+11. 94

-12.27

-11. 29

-0.36

-11. 62

+11.66

-0.25

-0.13

-0.41

-0.17

-0.26

-0.16

+0.58

+0.48

-0.58

+1. 01

-0.64

+2.74

-0.83

-0.23

-11.27

-13.24

-11. 39

+1.15

-13.33

+10.73

+11. 94

-11.23

+11. 27

+12.18

-11.89

-0.25

-11. 94

-11.67

+0.47

+0.47

-0.78

-1.28

-0.29

-0.11

-0.31

-0.25

-0.15

-0.13

-0.26

-3.71

-3.70

-3.71

-3.71

-3.71

-3.71

-3.71

-3.71

-3.71

-3.71

-3.71

-3.71 TO+O.O TO+9.1 TO+18.2 TO+27.3 TO+36.5 TO+45.6 TO+54.7 TO+63.8 TO+72.9 TO+82.0 TO+91.1 05/02/02 13:30:49 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 009 009 009 UTE UTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE 011 011 UTE UTE UTE UTE UTE UTE 010 010 007 007 009 009 014 014 007 007 009 009 015 015 UTE UTE UTE UTE LTS LTS LTS LTS 013 013 UTE UTE LTE LTE LTE LTE UTE UTE LTE LTE LTE LTE UTE UTE UTE UTE LTS LTS UTE UTE 009 009 008 008 009 009 015 015 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS TR TR TR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 2053 2053 2053 2053 2053 2053 2054 2054 2053 2053 2053 2053 2054 2054 2053 4026 4026 2054 4085 4085 4085 2053 4026 4026 2053 2054 4026 2092 2092 2125 4057 4057 4057 4057 4057 4057 4057 2093 4104 4065 4065 4065 4065 4065 4065 4065 4065 4065 4065 2092 4065 4065 4065 4065 4065 4065 2088 2089 2088 2089 2089 2089 2088 2088 2088 2088 2088 2088 2088 2088 2088 2088 2088 2088 2088 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 135 of 155 PROBE 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460S1 460HR 460SI 460S1 46081 460HR 46081 46081 460HR 460HR 460S1 460HR 460HR 460HR 46081 46081 46081 46081 46081 46081 46081 460HR 460S1 460SI 460S1 460SI 460SI 46081 460SI 460SI 460SI 46081 460SI 460HR 460SI 460S1 460S1 460S1 46081 46081 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR

Frarnatome ANP Inc.

05/02/02 13:30:50 Customer Name: Oconee Unit 1 Component: S/G B Page 136 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

0.00 0

P 3 TWO 0 UTE

-3.71 TO+95.7 UTE UTS 2088 INLET 460HR 0.51 31 P 3 TWO 32 UTE

-3.71 TO+I04.8 UTE UTS 2088 INLET 460HR 0.64 25 P 3 TWO 42 UTE

-3.71 TO+113.9 UTE UTS 2088 INLET 460HR 0.77 25 P 3 TWO 54 UTE

-3.71 TO+123.0 UTE UTS 2088 INLET 460HR

1. 01 23 P 3 TWO 77 UTE

-3.71 TO+132.2 UTE UTS 2088 INLET 460HR 0.80 26 P 3 TWO 57 UTE

-3.71 TO+141.3 UTE UTS 2088 INLET 460HR 0.83 22 P 3 TWO 60 UTE

-3.71 TO+150.4 UTE UTS 2088 INLET 460HR 0.62 26 P 3 TWO 41 UTE

-3.71 TO+159.5 UTE UTS 2088 INLET 460HR 0.64 23 P 3 TWO 43 UTE

-3.71 TO+168.6 UTE UTS 2088 INLET 460HR 0.54 25 P 3 TWO 34 UTE

-3.71 TO+177.7 UTE UTS 2088 INLET 460HR 0.50 21 P 3 TWO 31 UTE

-3.71 TO+186.8 UTE UTS 2088 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.71 TO+195.9 UTE UTS 2088 INLET 460HR 129 50 2.97 178 1 ONT UTE

-7.36 UTE UTE 4015 INLET 460SI 129 52 3.23 30 2

TEA UTE

-0.29 UTE UTE 2053 INLET 460HR 0.87 21 2

TWO 60 UTE

-1.19 UTE UTE 2053 INLET 460HR 0.87 21 2

SVI UTE

-1.19 UTE UTE TR 2053 INLET 460HR 129 60 5.17 26 2

TEA UTE

-0.20 UTE UTE 2054 INLET 460HR 129 66

1. 38 28 2

TEA UTE

-0.25 UTE UTE 2054 INLET 460HR 129 71 4.45 30 2

TEA UTE

-0.24 UTE UTE 2053 INLET 460HR 129 75 0.45 21 2

SAl UTE

-3.53 UTE UTS 2053 INLET 460HR 0.45 21 2

TWO 60 UTE

-3.53 UTE UTS 2053 INLET 460HR 129 77

1. 05 22 2

SAl UTE

-1.19 UTE UTE TR 2053 INLET 460HR

1. 05 22 2

TWO 64 UTE

-1.19 UTE UTE 2053 INLET 460HR 129 79 4.60 29 2

TEA UTE

-0.32 UTE UTE 2053 INLET 460HR 129 80 6.97 24 2

TEA UTE

-0.20 UTE UTE 2054 INLET 460HR 129 81 0.17 90 2

VOL UTS

-5.59 UTS UTS 4016 INLET 460SI 4.34 29 2

TEA UTE

-0.36 UTE UTE 2053 INLET 460HR 129 83 5.28 30 2

TEA UTE

-0.32 UTE UTE 2053 INLET 460HR 129 86 2.28 32 2

TEA UTE

-0.22 UTE UTE 2054 INLET 460HR 129 89 3.43 191 1 ONT UTE

-11. 38 UTE UTE 4026 INLET 460SI 2.74 188 1 ONT LTE

+11. 52 LTE LTE 4026 INLET 460SI 129 91 8.42 179 1 ONT UTE

-11. 78 UTE UTE 4026 INLET 460SI 6.77 181 1 ONT LTS

-11.81 LTS LTS 4026 INLET 460S1 129 93 3.76 28 2

TEA UTE

-0.28 UTE UTE 2053 INLET 460HR 129 94 0.32 26 p 3 TWO 7 011

+0.84 011 011 WAR 4026 INLET 460SI 130 1 0.12 85 2

VOL 009

+1.79 009 009 4057 OUTLET 460SI 130 2 0.11 77 2

VOL 014

+1. 40 014 014 4057 OUTL.ET 460SI 4.84 21 2

TEA UTE

-0.15 UTE UTE 2089 INLET 460HR 130 3 2.50 21 2

TEA UTE

-0.16 UTE UTE 2088 INLET 460HR 130 5 0.99 47 2

TEA UTE

-0.21 UTE UTE 2088 INLET 460HR 130 6 0.18 82 2

VOL 005

+1.05 005 005 4057 OUTLET 460SI 130 7 0.22 52 P 3 TWO 5 010

+0.55 010 010 WAR 4057 OUTLET 460SI

1. 48 23 2

TEA UTE

-0.24 UTE UTE 2088 INLET 460HR 130 8 0.18 71 2

VOL 013

+1. 27 013 013 4057 OUTLET 460SI 2.48 29 2

TEA UTE

-0.15 UTE UTE 2089 INLET 460HR 130 10 0.48 109 2 VOL 014

+0.83 014 014 4057 OUTLET 460S1 130 11 0.48 30 P 3 TWO 11 009

-0.59 009 009 WAR 4057 OUTLET 460SI 130 16 7.00 176 1 DNT 009

+0.59 009 009 4057 OUTLET 460SI 130 17 3.72 27 2

TEA UTE

-0.37 UTE UTE 2088 INLET 460HR 130 19 6.53 173 1 ONT LTE

+11. 88 LTE LTE 4060 OUTLET 460SI 3.13 171 1 ONT UTE

-11. 43 UTE UTE 4060 OUTLET 460SI l30 21 7.48 177 1 ONT LTE

+11. 94 LTE LTE 4060 OUTLET 460SI 0.19 43 p 3 TWD 5 013

+0.79 013 013

~"lAR 4060 OUTLET 460S1 6.94 180 1 ONT UTE

-11. 62 UTE UTE 4060 OUTLET 460SI 1.39 26 2

TEA UTE

-0.29 UTE UTE 2088 INLET 460HR 130 22 7.31 169 1 ONT LTE

+12.09 LTE LTE 4065 OUTLET 460SI 6.36 173 1 ONT UTE

-11.62 UTE UTE 4065 OUTLET 460SI l30 24 8.80 181 1 DNT LTS

-11. 93 LTS LTS 4065 OUTLET 460SI 10.20 180 1 ONT UTE

-11. 52 UTE UTE 4065 OUTLET 460SI l30 25 0.22 71 P 4 TWO 5 007

-0.72 007 007 WAR 4065 OUTLET 460SI 130 28 2.06 25 2

TEA UTE

-0.39 UTE UTE 2088 INLET 460HR 130 29 3.84 25 2

TEA UTE

-0.19 UTE UTE 2089 INLET 460HR 130 30 1.24 146 p 3 TWO 23 010

-0.79 010 010 WAR 4065 OUTLET 460SI 1.48 27 2

MAl UTE

-3.50 UTE UTS TR 2088 INLET 460HR 1.48 27 2

TWO 83 UTE

-3.50 UTE UTS 2088 INLET 460HR 130 35 1.60 28 2

TEA UTE

-0.08 UTE UTE 2089 INLET 460HR l30 37 0.12 128 2 VOL 005

+15.87 005 005 4061 OUTLET 460S1 130 42 2.69 26 2

TEA UTE

-0.28 UTE UTE 2088 INLET 460HR 130 43 0.99 28 P 1 SCI UTE

-3.59 UTE UTS 2089 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-3.59 TO+351.1 UTE UTS 2089 INLET 460HR 0.28 17 P 3 TWO 26 UTE

-3.59 TO+O.O UTE UTS 2089 INLET 460HR 0.54 23 P 3 TWO 44 UTE

-3.59 TO+8.9 UTE UTS 2089 INLET 460HR 0.59 22 P 3 TWD 48 UTE

-3.59 TO+17.8 UTE UTS 2089 INLET 460HR 0.57 29 P 3 TWO 46 UTE

-3.59 TO+26.7 UTE UTS 2089 INLET 460HR 0.61 19 P 3 TWO 49 UTE

-3.59 TO+35.6 UTE UTS 2089 INLET 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS ~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 130 44 130 46 130 47 130 51 130 52 130 54 130 55 130 56 130 57 130 63 130 64 130 66 130 68 130 69 130 71 130 72 130 73 130 79 130 82 130 85 130 86 130 90 130 91 130 92 131 1 131 4 131 6 131 7 131 14 131 17 131 18 131 19 131 21 131 22 131 23 131 24 131 26 131 27 131 28 131 29 0.52 0.29 0.31 0.31 0.25 0.34 0.54 0.76 0.75 0.48 0.42 0.35 0.23 0.14 0.00 4.60 0.95

1. 71
1. 71
1. 30 2.91 2.59
1. 45 3.27 6.22 1.14
1. 81
1. 81 0.17 6.16 0.10
1. 74 0.78 4.63 6.28 1.02 1.02 4.22 4.42 4.07 2.19 3.65 6.91 4.79 3.98 2.95 0.33 0.47 3.30 0.35 2.53 0.17 0.37
1. 25 1.25 0.39
1. 09 3.88 0.13 8.46 9.20 7.39 2.05 10.25 6.13 7.22 2.85 5.17 2.31 0.30 0.54 0.64 0.31 0.39 0.54 18 10 21 25 21 29 27 24 25 26 16 15 24 22 o

30 20 26 26 22 29 27 35 35 208 26 31 31 51 21 15 14 26 32 26 36 36 27 23 29 32 31 183 30 183 30 25 139 24 87 23 79 28 31 31 70 P 3 TWO 43 P 3 TWO 26 P 3 TWO 28 P 3 TWO 28 P 3 TWO 24 P 3 TWO 30 P 3 TWO 44 P 3 TWO 58 P 3 TWO 57 P 3 TWO 41 P 3 TWO 36 P 3 TWO 31 P 3 TWO 22 P 3 TWO 14 P 3 TWO 0 2

TEA 2

TEA 2

SAl 2

TWO 81 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

MAl 2

TWO 83 P 3 TWO 3 2

TEA P 3 TWO 1 2

TEA 2

TEA 2

TEA 2

TEA 2

SAl 2

TWO 99 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 1

ONT 2

TEA 1

ONT 2

TEA P 3 TWO 7 P 3 TWO 7 2

TEA P 3 TWO 8 2

TEA 2

VOL P 3 TWO 9 2

MAl 2

TWO 97 2

VOL 3 TWO 22 ONT 61 P

179 1 94 2

174 1 181 1 179 1 181 1 182 1 172 1 183 1 24 2

174 1 177 1 134 P 3 87 P 3 56 P 3 42 P 3 33 2

96 VOL ONT ONT ONT ONT ONT ONT ONT TEA ONT ONT TWO 7 TWO 12 14 8

TWO TWO TEA P 3 TWO 13 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 007 UTE 007 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE UTE 011 010 UTE 010 UTE 007 010 UTE UTE 014 010 013 013 LTE UTE LTE LTE UTE LTE UTE UTE LTE UTE 009 010 009 009 UTE 009

-3.59

-3.59

-3.59

-3.59

-3.59

-3.59

-3.59

-3.59

-3.59

-3.59

-3.59

-3.59

-3.59

-3.59

-3.59

-0.33

-0.21

-1.19

-1.19

-0.31

-0.20

-0.16

-0.21

-0.33

-0.19

-0.39

-3.55

-3.55

+0.59

-0.18

-0.33

-0.13

-0.25

-0.43

-0.17

-3.35

-3.35

-0.29

-0.11

-0.22

-0.11

-0.46

-11. 68

-0.25

+11.71

-0.45

-0.28

+0.72

-0.24

+0.62

-0.22

+0.90

+0.68

-3.50

-3.50

-0.79

-0.68

-13.33

+1. 59

+11. 69

-11. 90

+11. 38

+13.25

-12.05

+11. 98

-12.25

-0.12

+11.94

-11.78

+0.67

+0.58

-0.61

-0.68

-0.31

-0.64 TO+44.4 TO+53.3 TO+62.2 TO+71.1 TO+80.0 TO+88.9 TO+97.8 T0+106.7 TO+115.6 TO+124.4 T0+133.3 TO+142.2 TO+151.1 TO+160.0 TO+168.9 05/02/02 13:30:52 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UT5 UTE UT5 UTE UTS UTE UT5 UTE UT5 UTE UT5 UTE UTS UTE UT5 UTE UT5 UTE UTS UTE UTS UTE UTS UTE UT5 UTE UTS UTE UT5 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS 007 007 UTE UTE 007 007 UTE UTE UTE UTE UTE UTE UTE UTE UTE UT5 UTE UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE UTE UTE 011 011 010 010 UTE UTE 010 010 UTE UTE 007 007 010 010 UTE UT5 UTE UT5 014 014 010 010 013 013 013 013 LTE LTE UTE UTE LTE LTE LTE LTE UTE UTE LTE LTE UTE UTE UTE UTE LTE LTE UTE UTE 009 009 010 010 009 009 009 009 UTE UTE 009 009 TR WAR WAR WAR WAR WAR WAR TR WAR WAR WAR WAR WAR WAR 2089 2089 2089 2089 2089 2089 2089 2089 2089 2089 2089 2089 2089 2089 2089 2088 2088 2089 2089 2057 2058 2058 2057 2057 2058 2057 2058 2058 4015 2054 4015 2054 2053 2053 2054 2053 2053 2053 2054 2080 2054 2053 4026 4026 4026 2053 4026 4026 2054 4057 2088 4057 4057 2088 2088 4057 4057 4057 4057 4057 4057 4057 4057 4057 4057 4057 2089 4060 4060 4060 4060 4060 4060 2088 4060 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET Page 137 of 155 PROBE 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 46051 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460SI 460SI 460HR 460SI 460SI 460HR 46051 460HR 460SI 460SI 460HR 460HR 460SI 460SI 460SI 46051 460SI 460SI 460SI 460SI 46051 46051 46051 460HR 460SI 46051 46051 46051 460SI 460S1 460HR 460S1

Framatome ANP Inc.

05/02/02 13:30:54 Customer Name: Oconee Unit 1 Component: S/G B Page 138 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS - MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===
1. 83 23 2

TEA UTE

-0.12 UTE UTE 2089 INLET 460HR 131 30 2.00 19 2

TEA UTE

-0.24 UTE UTE 2088 INLET 460HR 131 38 2.82 27 2

TEA UTE

-0.33 UTE UTE 2088 INLET 460HR 131 42

1. 02 27 2

TEA UTE

-0.29 UTE UTE 2088 INLET 460HR 131 43 0.29 65 2

VOL UTE

-1. 07 UTE UTE 2089 INLET 460HR 131 50 4.54 31 2

TEA UTE

-0.31 UTE UTE 2057 INLET 460HR 131 52 2.90 27 2

TEA UTE

-0.37 UTE UTE 2057 INLET 460HR 8.28 166 1 ONT 013

+10.90 013 013 4015 INLET 460SI 3.51 184 1 ONT 009

+7.51 009 009 4015 INLET 460SI 0.53 70 P 3 TWO 8 009

+0.59 009 009 WAR 4015 INLET 460SI 131 59 5.01 172 1 ONT LTE

+10.24 LTE LTE 4085 OUTLET 460SI 1.25 29 2

TEA UTE

-0.16 UTE UTE 2058 INLET 460HR 0.61 57 P 3 TWO 9 009

+0.66 009 009 WAR 4015 INLET 460SI 0.27 65 P 3 TWO 4 007

+0.60 007 007 WAR 4015 INLET 460SI 131 60 5.13 179 1 ONT LTE

+10.18 LTE LTE 4085 OUTLET 460SI 5.94 28 2

TEA UTE

-0.30 UTE UTE 2057 INLET 460HR 7.43 173 1 ONT UTE

-10.72 UTE UTE 4015 INLET 460SI 4.97 30 2

TEA UTE

-0.19 UTE UTE 4015 INLET 460S1 131 62 0.77 110 P 3 TWO 11 010

-0.70 010 010 WAR 4015 INLET 460S1 131 63

1. 74 32 2

TEA UTE

-0.11 UTE UTE 2058 INLET 460HR 131 66 5.32 30 2

TEA UTE

-0.13 UTE UTE 2057 INLET 460HR 131 67 2.23 41 2

TEA UTE

-0.12 UTE UTE 2058 INLET 460HR 0.81 103 P 3 TWO 17 009

+0.63 009 009 WAR 4015 INLET 460S1 131 68 2.18 28 2

MAl UTE

-3.65 UTE UTS 2057 INLET 460HR 2.18 28 2

TWO 82 UTE

-3.65 UTE UTS 2057 INLET 460HR l31 76 0.21 50 2

VOL 007

+1. 32 007 007 4016 INLET 460S1 l31 80 0.59 137 P 3 TWO 11 009

+0.63 009 009 WAR 4016 INLET 460S1 4.20 29 2

TEA UTE

-0.19 UTE UTE 2057 INLET 460HR 131 81 0.62 147 P 3 TWO 12 009

+0.66 009 009 WAR 4016 INLET 460S1 0.41 98 P 3 TWO 8 009

+0.68 009 009 WAR 4016 INLET 460S1 131 83 0.20 107 2 VOL LTS

+7.32 LTS LTS 4016 INLET 460S1 4.27 33 2

TEA UTE

-0.26 UTE UTE 2057 INLET 460HR l31 89 3.58 34 2

TEA UTE

-0.34 UTE UTE 2057 INLET 460HR 0.45 49 P 3 TWO 9 011

-0.37 011 011 WAR 4026 INLET 460S1 0.29 123 P 3 TWO 4 01l

+0.33 01l 01l WAR 4026 INLET 460S1 l31 90 2.13 25 2

TEA UTE

-0.15 UTE UTE 2058 INLET 460HR 0.28 95 P 3 TWO 6 008

-0.55 008 008 V?AR 4026 INLET 460S1 132 3 0.11 88 2

VOL 013

+2.75 013 013 4057 OUTLET 460S1

1. 63 17 2

TEA UTE

-0.30 UTE UTE 2088 INLET 460HR 132 4 0.12 87 2

VOL 013

+0.98 013 013 4057 OUTLET 460S1 l32 5 2.18 37 2

TEA UTE

-0.25 UTE UTE 2088 INLET 460HR 132 7 0.35 24 P 3 TWO 8 010

+0.48 010 010 WAR 4057 OUTLET 460S1 132 14 0.81 24 2

TEA UTE

-0.16 UTE UTE 2089 INLET 460HR 132 17 4.17 28 2

TEA UTE

-0.29 UTE UTE 2088 INLET 460HR l32 18 3.50 168 1 ONT UTE

-8.62 UTE UTE 4057 OUTLET 460S1 2.83 174 1 ONT UTE

-7.98 UTE UTE 4057 OUTLET 460S1 4.32 188 1 ONT UTE

-5.08 UTE UTE 4057 OUTLET 460S1 132 19 3.29 21 2

TEA UTE

-0.28 UTE UTE 2088 INLET 460HR l32 22 0.31 132 P 3 TWO 7 007

-0.59 007 007 WAR 4060 OUTLET 460S1 132 23 0.32 45 P 3 TWO 8 010

+0.46 010 010 WAR 4060 OUTLET 460S1 l32 24 0.63 69 P 3 TWO 14 009

-0.64 009 009 WAR 4060 OUTLET 460S1 132 25 0.26 117 P 3 TWO 6 010

+0.46 010 010 WAR 4060 OUTLET 460S1 l32 29 0.34 64 P 3 TWO 8 009

-0.73 009 009 WAR 4060 OUTLET 460S1 0.18 64 2

VOL 015

-0.90 015 015 4060 OUTLET 460S1 132 31

1. 67 24 2

TEA UTE

-0.17 UTE UTE 2089 INLET 460HR 132 34 1.71 24 2

TEA UTE

-0.27 UTE UTE 2089 INLET 460HR 132 36 7.72 26 2

TEA UTE

-0.20 UTE UTE 2089 INLET 460HR l32 47 4.57 27 2

TEA UTE

-0.13 UTE UTE 2058 INLET 460HR l32 50 2.02 30 2

MAl UTE

-3.52 UTE UTS 2057 INLET 460HR 2.02 30 2

TWO 89 UTE

-3.52 UTE UTS 2057 INLET 460HR 132 51 2.84 23 2

TEA UTE

-0.10 UTE UTE 2058 INLET 460HR 132 53

1. 65 44 2

TEA UTE

-0.13 UTE UTE 2058 INLET 460HR 132 54 5.43 27 2

TEA UTE

-0.22 UTE UTE 2057 INLET 460HR

1. 69 33 2

TEA UTE

-0.23 UTE UTE 4015 INLET 460S1 10.18 173 1 ONT UTE

-11.36 UTE UTE 4015 INLET 460S1 10.72 174 1 ONT LTE

+10.44 LTE LTE 4015 INLET 460S1 132 56 10.68 175 1 ONT UTE

-10.63 UTE UTE 4015 INLET 460S1 8.27 170 1 ONT LTE

+10.28 LTE LTE 4015 INLET 460S1 l32 57 6.03 31 2

TEA UTE

-0.21 UTE UTE 2057 INLET 460HR l32 58 5.35 27 2

TEA UTE

-0.13 UTE UTE 2058 INLET 460HR 132 61 6.28 29 2

TEA UTE

-0.22 UTE UTE 2057 INLET 460HR 132 62 4.18 27 2

TEA UTE

-0.10 UTE UTE 2058 INLET 460HR 132 63 0.42 52 P 3 TWO 10 009

+0.61 009 009 WAR 4015 INLET 460SI 132 64 0.54 79 P 3 TWO 12 009

+0.64 009 009 WAR 4015 INLET 460S1 132 66 1.05 21 2

TEA UTE

-0.22 UTE UTE 2058 INLET 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 132 67 132 70 132 74 132 75 132 76 132 77 132 79 132 80 132 81 132 83 132 84 133 1 133 2 133 8 133 9 133 11 133 12 133 13 133 16 133 17 133 18 133 21 133 22 133 24 133 25 133 27 133 29 133 32 133 33 133 38 133 45 133 47 133 50 133 53 133 58 133 59 133 61 133 62 133 63 133 65 133 66 133 67 133 70 133 71 133 78 133 81 133 83 133 84 133 85 133 86 134 1 134 2 134 3 134 5 5.64 7.38 6.65 0.42 0.22 6.48 0.38 10.48 0.18 12.92

1. 77 18.35 0.53 1.11 0.56 1.14 0.97 0.28 0.52 0.61 0.50 0.72 0.48 0.43 0.26 2.14 0.98 0.58 0.64 0.64
1. 36
1. 88 0.41 0.53 0.63 1.93 6.74 3.47
1. 51 4.09 3.74 0.51 0.51
1. 90 6.03 0.35 5.93 8.34 2.33 4.60
1. 64 0.68 2.45 1.19 1.19 5.78 4.43 1.19 0.72 1.28 11.19 0.07
11. 44 1.82 0.36
1. 93 0.56
1. 90 0.94 3.96 1.67 7.36 0.00 1.56 2.75 27 25 23 78 51 30 57 173 94 179 24 180 132 42 138 20 25 141 47 130 52 48 78 90 81 25 2

2 2

TEA TEA TEA P 3 TWO 8 P 3 TWO 4 2

TEA P 3 TWO 7 1

ONT 2

VOL 1

ONT 2

TEA 1

ONT P 3 TWO 8 2

TEA P 3 TWO 8 2

TEA 2

TEA P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 2

TWO 7 TWO 13 15 12 17 11 10 6

TWO TWO TWO TWO TWO TWO 2

TEA TEA 3 TWO 14 SAl TWO 81 TEA TEA 20 126 P 26 2

26 2

26 2

25 2

85 122 123 20 P 4 TWO 11 P 3 TWO 12 P 3 TWO 14 2

TEA 22 29 130 24 209 22 22 2

TEA 2

TEA 1

VOL 2

TEA 2

TEA 2

SVI 2

TWO 62 2

TEA 25 189 30 p

169 1 166 1 33 2

23 2

28 2

51 P

21 2

25 2

25 2

174 1 28 2

49 2

66 1

ONT 3 TWO 8 ONT ONT TEA TEA TEA 3 TWO 10 TEA SVI TWO 69 ONT TEA TEA P 3 TWO 14 P 3 TWO 22 1

ONT 83 173 98 174 28 119 23 147 16 120 24 13 27 o

5 19 2

VOL 1

ONT 2

TEA P 3 TWO 5 2

TEA P 3 TWO 8 2

TEA P 3 TWO 21 2

TEA 2

TEA P 1 P 3 P 3 P 3 MCI TWO 0 TWO 19 TWO 35 UTE UTE UTE 009 009 UTE 009 009 011 009 UTE 009 011 UTE 011 UTE UTE 009 010 009 008 009 009 010 009 UTE UTE 010 UTE UTE UTE UTE 009 009 009 UTE UTE UTE 004 UTE UTE UTE UTE UTE 002 008 UTE LTE UTE UTE UTE 009 UTE UTE UTE 005 UTE UTE 009 009 009 011 009 UTE 011 UTE 011 UTE 014 UTE UTE UTE UTE UTE UTE

-0.36

-0.13

-0.13

+0.67

-0.70

-0.14

-0.69

-0.55

+1.82

-0.37

-0.19

+0.01

-0.41

-0.13

+0.65

-0.27

-0.22

+0.75

-0.74

-0.68

-0.24

+0.54

-0.68

+0.45

-0.71

-0.20

-0.27

+0.51

-3.43

-3.43

-0.19

-0.17

-0.66

-0.65

-0.73

-0.16

-0.10

-0.20

+17.47

-0.09

-0.08

-1.11

-1.11

-0.27

-12.67

+0.54

-10.79

+10.72

-0.10

-0.13

-0.31

-0.57

-0.10

-1. 01

-1. 01

-13.45

-0.19

-0.17

+0.60

+0.70

-0.77

+1.18

-0.47

-0.36

-0.36

-0.17

-0.50

-0.28

-0.75

-0.23

-0.26

-0.29

-0.29

-0.29

-0.29 T0+18.2 TO+27.3 TO+36.5 05/02/02 13:30:56 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE UTE UTE 009 009 009 009 UTE UTE 009 009 009 009 011 011 009 009 UTE UTE 009 009 011 011 UTE UTE 011 011 UTE UTE UTE UTE 009 009 010 010 009 009 008 008 009 009 009 009 010 010 009 009 UTE UTE UTE UTE 010 010 UTE UT8 UTE UT8 UTE UTE UTE UTE 009 009 009 009 009 009 UTE UTE UTE UTE UTE UTE 004 004 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 002 002 008 008 UTE UTE LTE LTE UTE UTE UTE UTE UTE UTE 009 009 UTE UTE UTE UTE UTE UTE 005 005 UTE UTE UTE UTE 009 009 009 009 009 009 011 011 009 009 UTE UTE 011 011 UTE UTE 011 011 UTE UTE 014 014 UTE UTE UTE UTE UTE UTS UTE UTS UTE UT8 UTE UTS WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR TR WAR WAR TR WAR WAR WAR WAR WAR CL 2057 2058 2058 4016 4016 2058 4016 4016 4016 4016 2058 4016 4026 2058 4026 2088 2088 4070 4070 4070 4070 4070 4068 4068 4068 2089 2088 4068 2089 2089 2088 2089 4065 4065 4065 2089 2088 2089 4061 2058 2058 2058 2058 2057 4015 4015 4015 4015 2058 2058 2057 4015 2058 2058 2058 4015 2058 2057 4016 4016 4016 4016 4016 2057 4026 2058 4026 2088 4073 2089 2088 2088 2088 2088 2088 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET Page 139 of 155 PROBE 460HR 460HR 460HR 46081 46081 460HR 46081 460SI 460S1 460S1 460HR 46081 46081 460HR 46081 460HR 460HR 460SI 460SI 460S1 46081 46081 46081 460SI 460S1 460HR 460HR 46081 460HR 460HR 460HR 460HR 46081 46081 46081 460HR 460HR 460HR 46081 460HR 460HR 460HR 460HR 460HR 460S1 46081 46081 460S1 460HR 460HR 460HR 46081 460HR 460HR 460HR 46081 460HR 460HR 46081 46081 46081 460S1 460S1 460HR 460S1 460HR 460S1 460HR 460S1 460HR 460HR 460HR 460HR 460HR 460HR

Framatome ANP Inc.

05/02/02 13:30:57 Customer Name: Oconee Unit 1 Component: S/G B Page 140 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -. MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

4.94 22 P 3 TWO 64 UTE

-0.29 TO+45.6 UTE UTS 2088 INLET 460HR 6.19 22 P 3 TWO 81 UTE

-0.29 TO+54.7 UTE UTS 2088 INLET 460HR 5.74 22 P 3 TWD 75 UTE

-0.29 TO+63.8 UTE UTS 2088 INLET 460HR 4.19 20 P 3 TWD 54 UTE

-0.29 TO+72.9 UTE UTS 2088 INLET 460HR 2.97 13 P 3 TWO 37 UTE

-0.29 TO+82.0 UTE UTS 2088 INLET 460HR 2.51 8

P 3 TWO 31 UTE

-0.29 TO+91.1 UTE UTS 2088 INLET 460HR

1. 69 8

P 3 TWO 21 UTE

-0.29 TO+100.3 UTE UTS 2088 INLET 460HR

1. 50 38 P 3 TWD 18 UTE

-0.29 TO+109.4 UTE UTS 2088 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.29 TO+118.5 UTE UTS 2088 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.29 TO+173.2 UTE UTS 2088 INLET 460HR 1.12 12 P 3 TWO 12 UTE

-0.29 TO+182.3 UTE UTS 2088 INLET 460HR 2.56 19 P 3 TWD 30 UTE

-0.29 TO+191. 4 UTE UTS 2088 INLET 460HR 4.27 20 P 3 TWO 57 UTE

-0.29 TO+200.5 UTE UTS 2088 INLET 460HR 4.93 22 P 3 TWD 70 UTE

-0.29 TO+209.6 UTE UTS 2088 INLET 460HR 4.17 22 P 3 TWO 55 UTE

-0.29 TO+218.7 UTE UTS 2088 INLET 460HR

1. 94 15 P 3 TWO 22 UTE

-0.29 TO+227.8 UTE UTS 2088 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-0.29 TO+237.0 UTE UTS 2088 INLET 460HR 134 7 0.43 40 P 3 TWD 11 009

-0.71 009 009 WAR 4070 OUTLET 460SI 0.33 22 P 3 TWD 8 010

+0.57 010 010 WAR 4070 OUTLET 460SI

1. 39 26 2

TEA UTE

-0.30 UTE UTE 2088 INLET 460HR 134 8 0.47 94 P 3 TWO 12 009

-0.72 009 009 WAR 4070 OUTLET 460SI 0.10 67 2

VOL 014

-1.17 014 014 4070 OUTLET 46051 134 9 0.83 85 P 3 TWD 19 009

-0.62 009 009 WAR 4070 OUTLET 460SI 134 10 0.47 92 P 3 TWO 12 009

-0.66 009 009 WAR 4070 OUTLET 460SI 2.20 26 2

TEA UTE

-0.19 UTE UTE 2089 INLET 460HR 134 11 0.79 70 P 3 TWO 18 009

-0.69 009 009 WAR 4068 OUTLET 460SI 0.23 18 p 3 TWO 6 010

+0.76 010 010 WAR 4068 OUTLET 460SI 134 12 0.39 111 P 3 TWO 10 009

-0.74 009 009 WAR 4068 OUTLET 460SI 0.44 26 P 1 SCI UTE

-3.13 UTE UTS 2089 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-3.13 TO+102.2 UTE UTS 2089 INLET 460HR 0.33 41 P 3 TWD 46 UTE

-3.13 TO+93.3 UTE UTS 2089 INLET 460HR 0.49 33 P 3 TWD 75 UTE

-3.13 TO+84.4 UTE UTS 2089 INLET 460HR 0.57 33 P 3 TWD 93 UTE

-3.13 TO+75.6 UTE UTS 2089 INLET 460HR 0.46 31 P 3 TWD 69 UTE

-3.13 TO+66.7 UTE UTS 2089 INLET 460HR 0.09 38 P 3 TWO 12 UTE

-3.13 TO+57.8 UTE UTS 2089 INLET 460HR 0.00 0

P 3 TWD 0 UTE

-3.13 TO+48.9 UTE UTS 2089 INLET 460HR 134 13 0.35 86 P 3 TWO 9 009

-0.. 70 009 009 WAR 4068 OUTLET 460SI 0.24 50 P 3 TWD 6 009

+0.54 009 009 WAR 4068 OUTLET 460SI 134 15

1. 22 13 2

TEA UTE

-0.21 UTE UTE 2088 INLET 460HR 134 19 0.28 55 p 3 TWD 7 008

+0.10 008 008 WAR 4068 OUTLET 460SI 0.29 67 P 3 TWD 8 009

-0.87 009 009 WAR 4068 OUTLET 460SI 134 20 0.33 69 P 3 TWO 9 010

+0.44 010 010 WAR 4068 OUTLET 460SI 134 21 0.53 108 P 3 TWO 12 010

+0.38 010 010 WAR 4068 OUTLET 460SI 134 24 0.23 100 P 4 TWO 6 009

-0.70 009 009 WAR 4065 OUTLET 460SI 134 25 0.29 75 P 4 TWO 8 007

-0.63 007 007 WAR 4065 OUTLET 460SI 2.08 32 2

TEA UTE

-0.11 UTE UTE 2089 INLET 460HR 134 34 2.10 181 1 DNT LTS

+13.53 LTS LTS 4061 OUTLET 46051 1.10 22 2

TEA UTE

-0.15 UTE UTE 2089 INLET 460HR 134 35 3.98 25 2

TEA UTE

-0.25 UTE UTE 2088 INLET 460HR 134 38 6.76 24 2

TEA UTE

-0.18 UTE UTE 2089 INLET 460HR 134 42 5.70 174 1 DNT 001

+5.23 001 001 4104 OUTLET 460SI 3.33 28 2

TEA UTE

-0.22 UTE UTE 2089 INLET 460HR 0.75 17 2

SAl UTE

-1.12 UTE UTE TR 2089 INLET 460HR 0.75 17 2

TWD 44 UTE

-1.12 UTE UTE 2089 INLET 460HR 134 48 2.10 38 2

TEA UTE

-0.20 UTE UTE 2057 INLET 460HR 134 49 4.44 27 2

TEA UTE

-0.16 UTE UTE 2058 INLET 460HR 134 50 2.23 24 2

TEA UTE

-0.30 UTE UTE 2057 INLET 460HR 134 54 3.69 29 2

TEA UTE

-0.29 UTE UTE 2057 INLET 460HR 134 55 8.80 173 1 ONT UTE

-11.36 UTE UTE 4016 INLET 460SI 0.50 101 P 3 TWD 10 009

-0.69 009 009 WAR 4016 INLET 460SI 6.07 3

1 DNT LTE

+10.69 LTE LTE 4016 INLET 460SI 134 56 7.10 175 1 DNT UTE

-10.88 UTE UTE 4016 INLET 460SI 0.62 109 P 3 TWD 12 009

-0.71 009 009 WAR 4016 INLET 460SI 6.95 174 1 DNT LTE

+10.47 LTE LTE 4016 INLET 460SI

1. 67 34 2

TEA UTE

-0.29 UTE UTE 2057 INLET 460HR 134 57 9.11 176 1 DNT UTE

-10.74 UTE UTE 4016 INLET 460SI 6.67 180 1 ONT LTE

+10.56 LTE LTE 4016 INLET 460SI 2.65 27 2

TEA UTE

-0.19 UTE UTE 2058 INLET 460HR 134 59 0.68 125 P 3 TWD 13 009

+0.65 009 009 WAR 4016 INLET 460SI 134 61 1.06 90 P 3 TWD 19 010

-0.74 010 010 WAR 4016 INLET 460SI 134 62 2.12 27 2

TEA UTE

-0.17 UTE UTE 2058 INLET 460HR 134 68 4.45 31 2

TEA UTE

-0.35 UTE UTE 2057 INLET 460HR 134 73

1. 06 131 P 3 TWD 19 009

+0.54 009 009 WAR 4016 INLET 460SI 134 74 0.42 80 P 3 TWD 8 009

-0.73 009 009 WAR 4016 INLET 46081 134 76 0.42 63 P 3 TWO 10 009

+0.80 009 009 WAR 4085 OUTLET 460SI

Framatome ANP Inc.

05/02/02 13:30:59 Customer Name: Oconee Unit 1 Component: S/G B Page 141 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -. MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

134 77 0.49 103 P 3 TWD l3 009

+0.73 009 009 WAR 4085 OUTLET 460SI 7.37 26 P 1 MCI UTE

-0.29 UTE UTS CL 2058 INLET 460HR 1.81 27 P 3 TWD 0 UTE

-0.29 TO+333.3 UTE UTS 2058 INLET 460HR 2.17 23 P 3 TWD 46 UTE

-0.29 TO+324.4 UTE UTS 2058 INLET 460HR 2.64 20 P 3 TWD 51 UTE

-0.29 TO+315.6 UTE UTS 2058 INLET 460HR 3.00 24 P 3 TWD 55 UTE

-0.29 TO+306.7 UTE UTS 2058 INLET 460HR 3.23 28 P 3 TWD 57 UTE

-0.29 TO+297.8 UTE UTS 2058 INLET 460HR 3.72 26 P 3 TWD 61 UTE

-0.29 TO+288.9 UTE UTS 2058 INLET 460HR 4.49 23 P 3 TWD 67 UTE

-0.29 TO+280.0 UTE UTS 2058 INLET 460HR 5.66 23 P 3 TWD 75 UTE

-0.29 TO+271.1 UTE UTS 2058 INLET 460HR 6.03 23 P 3 TWD 77 UTE

-0.29 TO+262.2 UTE UTS 2058 INLET 460HR 5.45 23 P 3 TWD 74 UTE

-0.29 TO+253.3 UTE UTS 2058 INLET 460HR 4.84 23 P 3 TWD 69 UTE

-0.29 TO+244.4 UTE UTS 2058 INLET 460HR 4.91 22 P 3 TWD 70 UTE

-0.29 TO+235.6 UTE UTS 2058 INLET 460HR 4.86 24 P 3 TWD 70 UTE

-0.29 TO+226.7 UTE UTS 2058 INLET 460HR 4.54 25 P 3 TWD 67 UTE

-0.29 TO+217.8 UTE UTS 2058 INLET 460HR 3.89 22 P 3 TWD 62 UTE

-0.29 TO+208.9 UTE UTS 2058 INLET 460HR 2.63 24 P 3 TWD 51 UTE

-0.29 TO+200.0 UTE UTS 2058 INLET 460HR

1. 38 31 P 3 TWD 0 UTE

-0.29 TO+191.1 UTE UTS 2058 INLET 460HR 0.62 197 P 3 TWD 0 UTE

-0.29 TO+93.3 UTE UTS 2058 INLET 460HR

1. 63 23 P 3 TWD 37 UTE

-0.29 TO+84.4 UTE UTS 2058 INLET 460HR 2.28 21 P 3 TWD 44 UTE

-0.29 TO+75.6 UTE UTS 2058 INLET 460HR 2.50 19 P 3 TWD 46 UTE

-0.29 TO+66.7 UTE UTS 2058 INLET 460HR 2.67 20 P 3 TWD 47 UTE

-0.29 TO+57.8 UTE UTS 2058 INLET 460HR 3.04 20 P 3 TWD 50 UTE

-0.29 TO+48.9 UTE UTS 2058 INLET 460HR 3.57 20 P 3 TWD 55 UTE

-0.29 TO+40.0 UTE UTS 2058 INLET 460HR 3.84 22 P 3 TWD 57 UTE

-0.29 TO+31.1 UTE UTS 2058 INLET 460HR 4.98 25 P 3 TWD 64 UTE

-0.29 TO+l3.3 UTE UTS 2058 INLET 460HR 4.33 23 P 3 TWD 60 UTE

-0.29 TO+22.2 UTE UTS 2058 INLET 460HR 5.64 24 P 3 TWD 69 UTE

-0.29 TO+4.4 UTE UTS 2058 INLET 460HR 5.63 22 p 3 TWD 69 UTE

-0.29 TO+355.6 UTE UTS 2058 INLET 460HR 4.61 20 P 3 TWD 62 UTE

-0.29 TO+346.7 UTE UTS 2058 INLET 460HR 2.63 18 P 3 TWD 47 UTE

-0.29 TO+337.8 UTE UTS 2058 INLET 460HR 1.86 23 P 3 TWD 0 UTE

-0.29 TO+328.9 UTE UTS 2058 INLET 460HR l34 80 l3.57 357 1 DNT 009

-0.40 009 009 4016 INLET 460SI 134 81 12.24 180 1 DNT 009

-0.25 009 009 4016 INLET 460SI 134 84 0.65 117 P 3 TWD 9 011

-0.56 011 011 WAR 4026 INLET 460SI 134 85 7.30 26 2

TEA UTE

-0.19 UTE UTE 2058 INLET 460HR 0.58 139 P 3 TWD 8 011

+0.05 011 Oll WAR 4026 INLET 460S1 0.44 144 P 3 TWD 6 Oll

+0.66 Oll Oll WAR 4026 INLET 460SI 135 1 0.35 103 P 3 TWD 9 Oll

+0.77 011 011 WAR 4073 OUTLET 460SI 0.20 70 2

VOL 013

+1. 38 013 013 4073 OUTLET 460SI l35 2 0.33 105 p 3 TWD 8 011

+0.74 011 011 WAR 4073 OUTLET 460SI 135 5 0.17 89 2

VOL 007

+0.85 007 007 4070 OUTLET 460S1 0.42 29 P 3 TWD 11 010

+0.69 010 010 WAR 4070 OUTLET 460SI 135 6 0.53 94 P 3 TWD 13 009

-0.67 009 009 WAR 4070 OUTLET 460SI 0.35 48 P 3 TWD 9 009

+0.71 009 009 WAR 4070 OUTLET 460SI 0.52 140 P 3 TWD 13 010

+0.70 010 010 WAR 4070 OUTLET 460SI 0.35 96 2

VOL 013

+0.89 013 013 4070 OUTLET 460S1 7.02 25 2

TEA UTE

-0.18 UTE UTE 2089 INLET 460HR 135 8 0.44 62 P 3 TWD 11 009

-0.65 009 009 WAR 4070 OUTLET 460SI 0.17 36 P 3 TWD 4 010

-0.74 010 010 WAR 4070 OUTLET 460SI 135 9 0.91 61 P 3 TWD 20 009

-0.71 009 009 WAR 4070 OUTLET 460SI 0.48 145 p 3 TWD 12 010

-0.72 010 010 WAR 4070 OUTLET 460S1 6.08 28 2

TEA UTE

-0.17 UTE UTE 2089 INLET 460HR l35 10 0.47 l30 P 3 TWD II 009

-0.69 009 009 WAR 4068 OUTLET 460SI 0.70 98 P 3 TWD 16 010

-0.53 010 010 WAR 4068 OUTLET 460SI 1.99 25 2

MAl UTE

-3.50 UTE UTS TR 2088 INLET 460HR

1. 99 25 2

TWD 72 UTE

-3.50 UTE UTS 2088 INLET 460HR 135 11 0.80 88 P 3 TWD 18 009

-0.74 009 009 WAR 4068 OUTLET 460SI 0.86 96 P 3 TWD 19 010

-0.66 010 010 WAR 4068 OUTLET 460SI l35 12 0.36 113 P 3 TWD 9 009

-0.45 009 009 WAR 4068 OUTLET 460S1 1.16 91 P 3 TWD 24 010

-0.69 010 010 WAR 4068 OUTLET 460SI 0.20 75 2

VOL 013

+0.92 013 013 4068 OUTLET 460SI l35 14 0.14 133 P 3 TWD 4 007

+0.65 007 007 WAR 4068 OUTLET 460SI 3.22 25 2

TEA UTE

-0.21 UTE UTE 2088 INLET 460HR 135 15 0.33 67 2

VOL 009

-0.68 009 009 4068 OUTLET 460SI 135 19 0.73 90 P 3 TWD 17 009

+0.59 009 009 WAR 4070 OUTLET 460SI 0.62 67 P 3 TWD 15 009

-0.72 009 009 WAR 4070 OUTLET 460SI 135 23 0.26 74 P 4 TWD 7 007

-0.72 007 007 WAR 4065 OUTLET 460SI 0.42 90 P 4 TWD 12 009

-0.67 009 009 WAR 4065 OUTLET 460SI 135 24 0.79 138 P 3 TWD 16 009

-0.71 009 009 WAR 4065 OUTLET 460SI 1.28 25 2

TEA UTE

-0.15 UTE UTE 2089 INLET 460HR l35 26 0.62 121 P 3 TWD 13 009

-0.65 009 009 WAR 4065 OUTLET 460SI 135 34 1.56 194 2 TEA UTE

-0.23 UTE UTE 2088 INLET 460HR

Framatome ANP Inc.

Customer Name: Oconee unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS ~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION l35 35 l35 38 l35 46 l35 48 135 49 135 50 l35 54 135 55 135 56 135 60 l35 62 135 67 135 68 l35 69 l35 70 l35 72 l35 73 135 74 l35 75 135 76 135 77 135 78 135 79 l35 80 135 82 136 1 l36 2 136 6 l36 11 l36 12 136 14 136 15 136 16 l36 18 l36 21 l36 27 l36 28 136 30 l36 32 136 33 l36 34 l36 35 l36 40 136 42 l36 43 l36 44 l36 46 l36 48 136 49 136 52 136 53 136 56 136 58 136 59 136 61 l36 62 l36 63 0.59 2.67 3.07 4.28 4.29

1. 05 3.46 0.64 4.40 0.34 0.26 2.79 2.68 0.89 0.28 0.30 0.32 0.29 0.61
1. 22 1.33 0.20 0.62 0.82 0.70 13.28 13.05 9.85 0.27 2.50 4.57 0.44 0.93 4.11 0.77 0.71
1. 00 3.44 0.18 0.34 0.80 0.33 0.31 0.34 3.70 0.38
1. 62 0.17 0.74 4.07 2.42
1. 49 2.60
1. 55 3.70 3.47 1.54 4.37 3.28
1. 74 6.98 1.93 0.54 0.68 1.15 0.64 0.27 3.22 0.37 3.01
1. 55 5.56 3.55 1.11 5.28 62 1

VOL 015 24 2

TEA UTE 28 2

TEA UTE 172 1 DNT LTS 32 2

TEA UTE o

P 3 TWD 15 009 29 2

TEA UTE o

P 3 TWD 8 009 28 2

TEA UTE o

P 3 TWD 5 009 o

P 3 TWD 4 009 27 2

TEA UTE 35 2

TEA UTE 33 2

TEA UTE o

P 3 TWD 4 008 o

P 3 TWD 4 008 95 2

VOL 007 47 P 3 TWD 6 007 103 P 3 TWD 12 008 85 P 3 TWD 21 009 89 P 3 TWD 23 009 64 2

VOL 007 66 P 3 TWD 12 009 134 P 3 TWD 15 009 143 P 3 TWD 13 009 o

1 ONT 008 170 1 DNT 009 172 1 DNT 009 135 P 3 TWD 5 007 27 2

TEA UTE 29 2

TEA UTE 148 P 3 TWD 9 009 23 2

TEA UTE 26 2

TEA UTE III P 3 TWD 18 010 97 P 3 TWD 17 010 2Q 2

TEA UTE 23 2

TEA UTE 43 P 3 TWO 4 007 122 2 VOL 009 22 2

TEA UTE 117 P 3 TWD 8 008 127 P 3 TWD 8 009 60 P 3 TWD 9 010 24 2

TEA UTE 41 P 3 TWD 10 009 17 2

TEA UTE 117 2 VOL 001 89 P 3 TWD 17 009 22 2

TEA UTE 23 2

TEA UTE 19 2

TEA UTE 20 2

TEA UTE 25 2

TEA UTE 37 2

TEA UTE 22 2

TEA UTE 25 2

TEA UTE 29 2

TEA UTE 31 2

TEA UTE 36 2

TEA UTE 25 2

TEA UTE 22 2

TEA UTE o

P 3 TWD 8 009 o

P 3 TWO 10 009 49 2

TEA UTE o

P 3 TWO 10 008 o

P 3 TWO 4 009 29 2

TEA UTE o

P 3 TWD 5 009 29 2

TEA UTE 28 2

TEA UTE 29 2

TEA UTE 28 2

TEA UTE o

P 3 TWD 14 007 29 2

TEA UTE

+11. 57

-0.33

-0.29

-8.55

-0.11

-0.71

-0.24

-0.72

-0.16

+0.79

-0.62

-0.27

-0.23

-0.30

+0.72

-0.55

+1. 24

-0.47

-0.16

+0.58

+0.68

+0.84

+0.69

+0.71

+0.62

+0.34

-0.24

-0.36

+0.66

-0.23

-0.28

+0.54

-0.28

-0.15

-0.72

+0.62

-0.20

-0.19

+0.59

-0.80

-0.24

-0.65

-0.70

-0.68

-0.22

-0.74

-0.34

+6.07

-0.70

-0.36

-0.14

-0.35

-0.29

-0.12

-0.25

-0.19

-0.21

-0.20

-0.25

-0.15

-0.15

-0.18

-0.70

+0.66

-0.15

+0.66

+0.69

-0.26

+0.68

-0.17

-0.22

-0.26

-0.37

+0.68

-0.35 05/02/02 13:31:01 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG 015 015 UTE UTE UTE UTE LTS LTS UTE UTE 009 009 WAR UTE UTE 009 009 WAR UTE UTE 009 009 WAR 009 009 WAR UTE UTE UTE UTE UTE UTE 008 008 WAR 008 008 WAR 007 007 007 007 WAR 008 008 WAR 009 009 WAR 009 009 WAR 007 007 009 009 WAR 009 009 WAR 009 009 WAR 008 008 009 009 009 009 007 007 WAR UTE UTE UTE UTE 009 009 WAR UTE UTE UTE UTE 010 010 WAR 010 010 WAR UTE UTE UTE UTE 007 007 WAR 009 009 UTE UTE 008 008 WAR 009 009 WAR 010 010 WAR UTE UTE 009 009 WAR UTE UTE 001 001 009 009 WAR UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 009 WAR 009 009 WAR UTE UTE 008 008 WAR 009 009 WAR UTE UTE 009 009 WAR UTE UTE UTE UTE UTE UTE UTE UTE 007 007 WAR UTE UTE 4061 2088 2057 4018 2058 4018 2057 4018 2058 4018 4018 2057 2057 2057 4018 4018 4016 4016 4016 4016 4016 4016 4016 4016 4016 4016 4016 4016 4016 2058 2057 4026 2088 2089 4070 4070 2088 2089 4070 4070 2088 4070 4070 4070 2089 4070 2088 4070 4070 2088

  • 2089 2088 2088 2089 2088 2089 2089 2057 2057 2058 2058 2058 4018 4018 2057 4018 4018 2057 4018 2058 2058 2057 2057 4018 2057 OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 142 of 155 PROBE 460SI 460HR 460HR 460SI 460HR 460SI 460HR 460SI 460HR 460SI 460SI 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460HR 460HR 460SI 460SI 460HR 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460HR 460SI 460HR 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460HR 460SI 460SI 460HR 460S1 460HR 460HR 460HR 460HR 460SI 460HR

Framatome ANP Inc.

05/02/02 13:31:03 Customer Name: Oconee Unit 1 Component: S/G B Page 143 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

0.65 0

P 3 TWO 8 008

+0.70 008 008 WAR 4018 INLET 460S1 136 64 4.96 28 2

TEA UTE

-0.15 UTE UTE 2058 INLET 460HR l36 67 0.56 107 P 3 TWO l3 007

-0.18 007 007 WAR 4085 OUTLET 460SI 0.21 130 P 3 TWO 5 008

+0.61 008 008 WAR 4085 OUTLET 460SI 136 68 2.01 116 P 3 TWO 31 009

+0.60 009 009 WAR 4016 INLET 460SI 0.30 32 P 3 TWO 6 007

+0.42 007 007 WAR 4016 INLET 460S1 136 70

1. 64 108 P 3 TWO 26 009

+0.68 009 009 WAR 4016 INLET 460S1 0.56 41 P 3 TWO 11 009

-0.70 009 009 WAR 4016 INLET 460S1 l36 71

1. 95 114 P 3 TWO 30 009

+0.74 009 009 WAR 4016 INLET 460S1 5.40 32 2

TEA UTE

-0.37 UTE UTE 2057 INLET 460HR 136 72

1. 79 109 p 3 TWO 28 009

+0.68 009 009 WAR 4016 INLET 460S1 5.22 27 2

TEA UTE

-0.14 UTE UTE 2058 INLET 460HR l36 73 10.15 186 1 ONT 008

-0.14 008 008 4085 OUTLET 460SI 5.30 32 2

TEA UTE

-0.38 UTE UTE 2057 INLET 460HR 136 74 0.50 122 P 3 TWO 10 010

+0.74 010 010 WAR 4016 INLET 460S1 l3.66 185 1 DNT 008

+0.14 008 008 4085 OUTLET 460S1

1. 79 29 2

TEA UTE

-0.19 UTE UTE 2058 INLET 460HR l36 75 7.62 177 1 DNT 008

+0.54 008 008 4085 OUTLET 460SI l36 76 9.65 169 1 ONT 009

-0.33 009 009 4016 INLET 460SI 8.90 174 1 ONT 008

-0.03 008 008 4016 INLET 460SI 5.88 27 2

TEA UTE

-0.18 UTE UTE 2058 INLET 460HR 136 81 2.35 24 2

TEA UTE

-0.18 UTE UTE 2058 INLET 460HR 0.39 25 P 3 TWD 8 011

-0.33 011 011 WAR 4026 INLET 460SI 137 1 0.59 99 P 3 TWO 15 014

+0.58 014 014 WAR 4073 OUTLET 460S1 0.44 ll2p 3 TWO 11 014

-0.75 014 014 WAR 4073 OUTLET 460SI 13.17 21 P 1 SCI UTE

-0.25 UTE UTS CL 2088 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.25 TO+77.5 UTE UTS 2088 INLET 460HR 3.63 24 P 3 TWO 27 UTE

-0.25 TO+86.6 UTE UTS 2088 INLET 460HR 2.94 26 P 3 TWO 22 UTE

-0.25 TO+95.7 UTE UTS 2088 INLET 460HR 4.53 19 P 3 TWO 35 UTE

-0.25 TO+104.8 UTE UTS 2088 INLET 460HR 6.18 20 P 3 TWO 49 UTE

-0.25 TO+1l3.9 UTE UTS 2088 INLET 460HR 6.94 20 P 3 TWO 56 UTE

-0.25 TO+123.0 UTE UTS 2088 INLET 460HR 7.65 21 P 3 TWO 64 UTE

-0.25 TO+132.2 UTE UTS 2088 INLET 460HR 7.52 21 P 3 TWO 62 UTE

-0.25 TO+141. 3 UTE UTS 2088 INLET 460HR 6.04 24 P 3 TWO 48 UTE

-0.25 TO+150.4 UTE UTS 2088 INLET 460HR 5.62 24 P 3 TWO 44 UTE

-0.25 TO+159.5 UTE UTS 2088 INLET 460HR 5.19 24 P 3 TWO 40 UTE

-0.25 TO+168.6 UTE UTS 2088 INLET 460HR 4.80 23 P 3 TWO 37 UTE

-0.25 TO+177.7 UTE UTS 2088 INLET 460HR 3.76 25 p 3 TWO 28 UTE

-0.25 TO+186.8 UTE UTS 2088 INLET 460HR 3.83 23 P 3 TWO 29 UTE

-0.25 TO+195.9 UTE UTS 2088 INLET 460HR 3.70 22 P 3 TWO 28 UTE

-0.25 TO+205.1 UTE UTS 2088 INLET 460HR 2.49 24 p 3 TWO 19 UTE

-0.25 TO+214.2 UTE UTS 2088 INLET 460HR

1. 74 22 P 3 TWO 13 UTE

-0.25 TO+223.3 UTE UTS 2088 INLET 460HR

1. 32 20 P 3 TWO 10 UTE

-0.25 TO+232.4 UTE UTS 2088 INLET 460HR 0.86 18 P 3 TWO 7 UTE

-0.25 TO+241.5 UTE UTS 2088 INLET 460HR 0.87 22 P 3 TWD 7 UTE

-0.25 TO+250.6 UTE UTS 2088 INLET 460HR 0.52 24 P 3 TWD 5 UTE

-0.25 TO+259.7 UTE UTS 2088 INLET 460HR 0.00 0

P 3 TWO 0 UTE

-0.25 TO+268.9 UTE UTS 2088 INLET 460HR 137 3 6.76 184 1 DNT LTE

+11. 98 LTE LTE 4070 OUTLET 460SI 0.11 98 2

VOL 007

+1.28 007 007 4070 OUTLET 460SI 8.94 178 1 ONT 010

-0.40 010 010 4070 OUTLET 460SI 0.97 41 2

TEA UTE

-0.25 UTE UTE 2088 INLET 460HR l37 5 5.03 177 1 ONT 010

-0.58 010 010 4070 OUTLET 460S1 1.16 18 2

TEA UTE

-0.24 UTE UTE 2088 INLET 460HR 137 6 0.68 104 P 3 TWO 16 009

-0.67 009 009 WAR 4070 OUTLET 460S1 6.16 177 1 ONT 010

-0.54 010 010 4070 OUTLET 460SI 3.65 20 2

TEA UTE

-0.16 UTE UTE 2089 INLET 460HR l37 7 7.85 173 1 ONT 010

-0.41 010 010 4070 OUTLET 460SI l37 8 0.68 113 P 3 TWD 16 009

-0.68 009 009 WAR 4070 OUTLET 460S1 8.75 169 1 ONT 010

-0.36 010 010 4070 OUTLET 460S1 l37 9 0.38 59 P 3 TWO 10 007

-0.57 007 007 WAR 4070 OUTLET 460SI 0.69 108 P 3 TWO 16 009

-0.68 009 009 WAR 4070 OUTLET 460S1 7.39 169 1 ONT 010

-0.34 010 010 4070 OUTLET 460S1 2.59 22 2

TEA UTE

-0.34 UTE UTE 2088 INLET 460HR 137 10 0.27 48 P 3 TWO 7 009

-0.70 009 009 WAR 4070 OUTLET 460SI 8.30 180 1 ONT 010

-0.38 010 010 4070 OUTLET 460SI 2.75 23 2

TEA UTE

-0.15 UTE UTE 2089 INLET 460HR l37 12 0.68 76 P 3 TWO 16 007

-0.70 007 007 WAR 4070 OUTLET 460S1 6.72 171 1 ONT 010

-0.54 010 010 4070 OUTLET 460S1 1.52 23 2

TEA UTE

-0.26 UTE UTE 2088 INLET 460HR 137 13 0.29 69 P 3 TWO 7 007

-0.61 007 007 WAR 4070 OUTLET 460SI 0.88 80 P 3 TWO 20 009

-0.69 009 009 WAR 4070 OUTLET 460SI

1. 65 19 2

TEA UTE

-0.24 UTE UTE 2089 INLET 460HR 137 14 0.41 100 P 3 TWO 10 009

-0.72 009 009 WAR 4070 OUTLET 460SI 137 15 0.69 100 P 3 TWO 16 009

-0.70 009 009 WAR 4070 OUTLET 460S1

Framatome ANP Inc.

Customer Name: Oconee unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION 137 20 l37 23 l37 24 l37 25 137 26 l37 30 137 32 137 33 137 34 137 37 137 38 137 39 137 41 137 42 137 45 137 46 137 48 137 49 137 50 l37 52 137 53 137 54 137 56 137 57 137 58 l37 59 137 60 137 61 137 62 137 63 137 64 137 65 137 66 l37 67 l37 68 137 69 l37 70 137 72 137 74 137 75 137 77 137 78

1. 53 0.58 0.60 0.13
1. 52 2.49 1.17 2.43 2.84 1.41
1. 93 3.57
1. 74 2.10 6.59 5.84 0.53 0.74 5.01 3.12 4.26
1. 80 0.35 2.01 4.03 0.57 0.34 3.02 0.33 0.32 4.44
1. 35 0.27 7.15 3.08 9.90 6.86 1.19 0.16 0.37 5.06 0.71 0.53 4.11 0.75 0.31 3.78 0.49 1.17 5.17 0.61 1.96 1.18 14.07 6.45
1. 04 0.65 0.21 7.66 11.33
1. 39 6.29 1.72 8.01 14.54 3.80 18.61 0.18 4.92 0.34 5.65 3.52 6.44 0.66 0.40 25 82 109 88 24 24 39 24 28 24 29 32 19 41 180 25 o o 27 30 34 30 o

29 30 o o 26 o o 31 38 o

173 29 181 34 o o o 28 o

o 32 o o 23 o o 182 o

2 TEA P 3 TWO 14 P 3 TWO 12 2

VOL 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 1

ONT 2

TEA P 3 TWO 7 P 3 TWO 10 2

TEA 2

TEA 2

TEA 2

TEA P 3 TWO 5 2

TEA 2

TEA P 3 TWO 8 P 3 TWO 5 2

TEA P 3 TWO 5 P 3 TWO 5 2

TEA 2

TEA P 3 TWO 4 1

ONT 2

TEA 1

ONT 2

TEA P 3 TWO 15 P 3 TWO 2 P 3 TWO 5 2

TEA P 3 TWO 9 P 3 TWO 7 2

TEA P 3 TWO 10 P 3 TWO 4 2

TEA P 3 TWO 7 P 3 TWO 16 1

ONT P 3 TWO 8 P 3 TWO 30 P 3 TWO 20 1

ONT 137 102 173 352 73 135 22 165 178 22 171 112 P 166 1 357 1 31 2

2 1

ONT P 3 TWO 19 P 3 TWO 12 P 3 TWO 4 1

ONT 1

ONT 2

TEA 1

ONT 1

3 TWO 27 ONT ONT TEA ONT 16 27 81 23 28 26 153 150 P 3 TWO 3 2

9 2

2 2

TEA PLP TEA TEA TEA P 3 TWO 10 P 3 TWO 6 UTE 007 009 011 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 005 UTE 009 009 UTE UTE UTE UTE 009 UTE UTE 009 009 UTE 009 009 UTE UTE 007 009 UTE 009 UTE 010 010 008 UTE 010 009 UTE 009 009 UTE 009 009 008 007 009 009 008 UTE 009 009 007 LTE 008 UTE UTE 009 LTE 008 UTE 008 007 UTE 014 UTE UTE UTE 010 010

-0.24

-0.18

-0.67

+1. 38

-0.20

-0.29

-0.28

-0.33

-0.16

-0.18

-0.09

-0.22

-0.18

-0.09

-5.06

-0.21

-0.77

-0.73

-0.16

-0.20

-0.21

-0.30

+0.16

-0.17

-0.30

+0.25

+0.69

-0.13

+0.69

+0.51

-0.17

-0.30

-0.56

+0.22

-0.25

+0.16

-0.14

-0.66

+0.69

-0.27

-0.32

-0.66

-0.68

-0.22

-0.68

+0.64

-0.17

-0.65

+0.57

+0.65

-0.59

+0.66

-0.69

-0.15

-11.23

+0.71

-0.67

+0.65

+10.05

+0.13

-0.20

-11.56

+0.56

+9.53

+0.22

-0.33

+0.43

+0.59

-0.30

+1. 30

-0.18

-0.36

-0.18

-0.68

+0.72 05/02/02 13:31:05 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE 007 007 WAR 009 009 WAR 011 011 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 005 005 UTE UTE 009 009 WAR 009 009 WAR UTE UTE UTE UTE UTE UTE UTE UTE 009 009 WAR UTE UTE UTE UTE 009 009 WAR 009 009 WAR UTE UTE 009 009 WAR 009 009 WAR UTE UTE UTE UTE 007 007 WAR 009 009 UTE UTE 009 009 UTE UTE 010 010 WAR 010 010 WAR 008 008 WAR UTE UTE 010 010 WAR 009 009 WAR UTE UTE 009 009 WAR 009 009 WAR UTE UTE 009 009 WAR 009 009 WAR 008 008 007 007 WAR 009 009 WAR 009 009 WAR 008 008 UTE UTE 009 009 WAR 009 009 WAR 007 007 WAR LTE LTE 008 008 UTE UTE UTE UTE 009 009 WAR LTE LTE 008 008 UTE UTE 008 008 007 007 WAR UTE UTE 014 014 UTE UTE UTE UTE UTE UTE 010 010 WAR 010 010 WAR 2089 4070 4065 4065 2089 2088 2088 2088 2089 2088 2089 2088 2089 2058 4018 2058 4018 4018 2057 2058 2057 2057 4018 2058 2057 4018 4018 2058 4018 4018 2058 2057 4018 4085 2057 4018 2058 4018 4018 4018 2057 4018 4018 2057 4018 4018 2058 4018 4018 4018 4018 4016 4016 4082 4016 4016 4016 4016 4016 4082 2058 4016 4016 4016 4082 2057 4016 4016 2057 4016 2058 2057 2058 4026 4026 INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 144 of 155 PROBE 460HR 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460SI 460S1 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460SI 460S1 460HR 460SI 460SI 460HR 460HR 460S1 460SI 460HR 460SI 460HR 460S1 460S1 460SI 460HR 460S1 460S1 460HR 460S1 460SI 460HR 460S1 460SI 460SI 460SI 460SI 460S1 460S1 460S1 460SI 460S1 460S1 460S1 460SI 460HR 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460HR 460HR 460HR 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 138 1 138 3 138 5 138 8 138 10 138 12 138 13 138 14 138 15 138 17 138 21 138 22 138 23 138 25 138 32 138 33 138 34 138 36 138 38 138 40 138 41 138 43 138 44 138 46 138 47 138 48 138 50 138 55 138 56 138 57 138 58 138 60 138 61 138 62 138 64 138 65 138 66 138 69 138 70 138 71 138 72 138 73 138 74 139 1 4.87 0.54 5.91 2.19 7.45 0.56 17.25 0.42 7.00 0.26 13.39 0.27 3.15 0.52 10.28 5.12 0.53 4.85 0.77 0.46 0.44 0.50 0.55 0.79

1. 52 0.41 8.85 4.36 0.50 0.13 1.54 0.36 0.14
1. 70 0.18 0.71
1. 75
1. 71 4.56 2.62 1.53 5.21 3.69 0.37 0.16 4.07 0.56 0.71 2.04 3.85 1.83 1.19 2.85 2.06 0.78 0.85 0.42 2.71 5.23 4.72 0.83 3.04 0.28
1. 29 5.21 5.66 8.80 19.07 2.30 6.20 3.62
1. 61 5.60 5.13 4.90 ONT 3 TWO 13 DNT TEA DNT 180 1 123 P 183 1 25 2

177 1 94 182 39 176 28 178 97 P 3 TWO 14 1

ONT P 3 TWO 11 1

ONT P 3 TWO 7 1

ONT 2

VOL 28 101 175 32 71 29 115 104 90 56 73 84 40 66 170 174 79 75 25 137 80 18 85 150 22 21 27 26 16 24 28 86 32 26 o o 18 29 31 26 22 25 o o o

23 30 29 o

31 o o 176 157 170 180 25 176 30 21 30 28 356 2

TEA P 3 TWO 13 1

ONT 2

TEA P 3 TWO 13 2

TEA P 3 TWO 18 P 3 TWO 12 P 3 TWO 11 P 3 TWO 12 P 3 TWO 13 P 3 TWD 19 2

TEA P 3 TWO 10 1

ONT 1

ONT P 4 TWO 14 2

VOL 2

TEA P 3 TWO 8 2

VOL 2

TEA 2

VOL P 3 TWO 15 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA P 3 TWO 8 P 3 TWO 4 2

TEA P 3 TWO 8 P 3 TWO 10 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA P 3 TWO 12 P 3 TWO 13 P 3 TWO 6 2

TEA 2

TEA 2

TEA P 3 TWD 11 2

TEA P 3 TWO 4 P 3 TWD 16 1

ONT 1

ONT 1

ONT 1

ONT 2

TEA 1

ONT 2

TEA 2

TEA 2

TEA 2

TEA 1

ONT LTE 010 UTE UTE LTE 009 010 013 UTE 009 010 014 UTE 009 010 UTE 009 UTE 008 009 007 009 010 009 UTE 009 009 015 009 013 UTE 009 011 UTE 012 009 UTE UTE UTE UTE UTE UTE UTE 009 009 UTE 009 009 UTE UTE UTE UTE UTE UTE 009 009 009 UTE UTE UTE 010 UTE 009 009 008 UTE LTE 008 UTE 008 UTE UTE UTE UTE UTS

+11.51

+0.37

-13.76

-0.25

+11.31

-0.43

-0.38

+0.75

-11. 27

-0.67

-0.39

+1. 64

-0.26

-0.69

-0.52

-0.22

-0.55

-0.21

-0.23

-0.69

+0.63

-0.62

-0.62

-0.66

-0.21

+0.76

+0.39

+1. 09

-0.59

+1. 05

-0.19

-0.63

+1. 36

-0.10

-0.97

-0.75

-0.20

-0.30

-0.17

-0.16

-0.33

-0.20

-0.29

-0.70

+0.72

-0.20

-0.69

+0.68

-0.14

-0.17

-0.16

-0.21

-0.26

-0.16

+0.63

+0.53

+0.27

-0.20

-0.33

-0.15

-0.64

-0.15

+0.65

+0.73

+0.51

-11. 37

+9.89

+0.00

-0.35

+0.38

-0.30

-0.14

-0.36

-0.16

+12.29 05/02/02 13:31:07 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG LTE LTE 010 010 WAR UTE UTE UTE UTE LTE LTE 009 009 WAR 010 010 013 013 WAR UTE UTE 009 009 WAR 010 010 014 014 UTE UTE 009 009 WAR 010 010 UTE UTE 009 009 WAR UTE UTE 008 008 WAR 009 009 WAR 007 007 WAR 009 009 WAR 010 010 WAR 009 009 WAR UTE UTE 009 009 WAR 009 009 015 015 009 009 WAR 013 013 UTE UTE 009 009 WAR 011 011 UTE UTE 012 012 009 009 WAR UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 009 WAR 009 009 WAR UTE UTE 009 009 WAR 009 009 WAR UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 009 WAR 009 009 WAR 009 009 WAR UTE UTE UTE UTE UTE UTE 010 010 WAR UTE UTE 009 009 WAR 009 009 WAR 008 008 UTE UTE LTE LTE 008 008 UTE UTE 008 008 UTE UTE UTE UTE UTE UTE UTE UTE UTS UTS 4073 4073 4073 2088 4073 4073 4073 4073 4073 4073 4073 4073 2088 4073 4073 2088 4073 2088 4073 4073 4070 4070 4070 4073 2088 4070 4104 4104 4065 4065 2088 4065 4065 2089 4065 4065 2089 2088 2089 2089 2088 2058 2057 4019 4019 2058 4018 4018 2058 2057 2058 2057 2058 2057 4018 4018 4018 2058 2057 2058 4018 2058 4018 4018 4018 4016 4016 4082 2057 4082 2057 2058 2057 2058 4076 OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET OUTLET INLET INLET INLET INLET OUTLET Page 145 of 155 PROBE 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460HR 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460SI 460HR 460HR 460HR 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460HR 460HR 460HR 460HR 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS ~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION 139 2 139 3 139 4 139 6 139 7 139 8 139 9 139 10 139 II 139 12 139 13 139 15 139 16 139 18 139 21 139 23 139 24 139 27 139 31 139 32 139 34 139 36 139 37 139 38 139 41 139 43 139 44 139 46 139 48 139 51 139 55 139 56 139 57 139 58 139 59 139 60 139 62 7.75 8.74

1. 46 7.17 18.87 6.68 2.98 18.93
1. 75 0.52 10.78 0.10 0.65 0.95 0.62 10.82 5.44 0.82 5.27 0.69 0.76 4.56 3.47 0.45 0.30 4.63 0.60 0.44 0.69 3.27
11. 23 0.51 3.74 0.32 5.33 3.85 2.01 4.25 3.91 3.25 2.15 7.75 3.10 5.14 8.86 2.80 3.66 3.77 0.53 4.28 3.10 1.25 0.57
1. 08 0.12 2.17 0.30 0.74 2.38 0.33 0.34 1.27 1.82 1.13 0.22 0.21 0.41 0.53 3.02 3.45 5.09 0.32 5.90 0.61 0.31 DNT DNT TEA DNT DNT DNT TEA DNT TEA 359 1 175 1 28 2

174 1 182 1 179 1 21 2

178 1 24 2

69 177 78 P 3 TWD 13 1

ONT 2

VOL 45 98 102 174 28 ll5 25 60 73 22 30 54 39 23 70 64 80 354 359 48 25 83 29 29 22 21 29 26 28 180 34 181 26 180 181 25 P 3 TWD 16 P 3 TWD 21 P 3 TWD 15 1

ONT 2

TEA P 3 TWO 19 2

TEA P 3 P 3 2

2 TWO 17 TWO 18 TEA TEA P 3 TWO II P 3 TWO 8 2

TEA P 3 TWD 14 P 3 TWO II P 3 TWO 16 1

DNT 1

ONT 2

VOL 2

TEA P 3 TWO 8 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 1

ONT 2

TEA 1

ONT 2

TEA 1

ONT 1

DNT 2

TEA 95 P

158 1 32 2

20 2

o P

14 2

100 2 27 2

o 3 TWO II ONT TEA TEA 3 TWO 8 P 3 P 3 P 1 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 2

TEA VOL TEA TWO 4 TWO 16 SCI TWO 0 TWO 24 85 30 227 26 22 21 24 21 236 93 82 26 30 25 o

25 o o 2

2 TWO TWO TWO TWO TWO TWO 47 56 44 20 o

9 TWO 12 TEA TEA TEA P 3 TWO 4 2

TEA P 3 TWo 8 P 3 TWO 4 UTE LTE UTE LTE 010 UTE UTE 010 UTE 014 010 013 007 009 009 010 UTE 009 UTE 009 009 UTE UTE 009 009 UTE 009 009 010 LTS 009 009 UTE 009 UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE UTE LTE 002 UTE 009 004 UTE UTE 009 UTE 010 UTE 009 010 UTE UTE UTE UTE UTE UTE UTE UTE 009 009 UTE UTE UTE 010 UTE 009 009

-11. 52

+11. 34

-0.22

+11. 80

-0.56

-11.47

-0.07

+0.06

-0.21

-0.68

+0.27

+0.89

-0.70

+0.09

-0.63

-0.33

-0.18

-0.50

-0.21

-0.53

-0.68

-0.21

-0.19

+0.66

-0.72

-0.28

-0.65

+0.69

-0.72

-9.78

+0.52

-0.46

-0.30

-0.96

-0.23

-0.20

-0.18

-0.21

-0.23

-0.17

-0.18

-11.46

-0.17

+11. 36

-0.28

+11.00

+ll.44

-0.16

+0.70

+12.95

-0.24

-0.26

-0.19

-0.24

-1. 72

-0.33

-0.66

-0.70

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.27

-0.69

+0.48

-0.17

-0.31

-0.17

-0.67

-0.35

-0.18

+0.73 TO+204.4 TO+213.3 TO+222.2 TO+231.1 TO+240.0 TO+248.9 TO+257.8 05/02/02 13:31:09 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE LTE LTE UTE UTE LTE LTE 010 010 UTE UTE UTE UTE 010 010 UTE UTE 014 014 010 010 013 013 007 007 009 009 009 009 010 010 UTE UTE 009 009 UTE UTE 009 009 009 009 UTE UTE UTE UTE 009 009 009 009 UTE UTE 009 009 009 009 010 010 LTS LTS 009 009 009 009 UTE UTE 009 009 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE UTE UTE LTE LTE 002 002 UTE UTE 009 009 004 004 UTE UTE UTE UTE 009 009 UTE UTE 010 010 UTE UTE 009 009 010 010 UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS 009 009 009 009 UTE UTE UTE UTE UTE UTE 010 010 UTE UTE 009 009 009 009 WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR CL WAR WAR WAR WAR WAR 4076 4109 2088 4073 4073 4073 2089 4073 2088 4073 4073 4073 4073 4073 4073 4073 2084 4073 2085 4073 4076 2085 2084 4076 4076 2085 4076 4076 4076 4076 4076 4076 2085 4068 2084 2084 2084 2085 2084 2084 2084 4104 2084 4037 2085 4037 4019 2058 4019 4019 2057 2057 4018 2058 4018 2057 4018 4019 2057 2057 2057 2057 2057 2057 2057 2057 4019 4019 2058 2057 2058 4018 2057 4018 4018 OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET OUTLET OUTLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 146 of 155 PROBE 460SI 460SI 460HR 460SI 460SI 460SI 460HR 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460HR 460SI 460SI 460HR 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460HR 460HR 460SI 460HR 460SI 460HR 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460HR 460HR 460HR 460SI 460HR 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryMI ROW TUBE VOLTS DEG CHN IND %TW LOCATION 139 63 139 64 139 66 139 67 139 68 139 70 139 72 139 73 140 6 1407 140 10 140 11 140 12 140 14 140 15 140 18 140 19 140 20 140 25 140 34 140 36 140 38 140 39 140 41 140 43 140 45 140 47 140 48 140 49 140 52 140 53 140 54 140 55 140 57 140 58 140 59 140 61 140 62 140 64 140 65 140 67 5.33 0.82 0.99 0.08 15.13 9.99 5.64 10.69 6.78

11. 41 6.80 8.95 6.37
11. 95 9.62 5.33 5.34 3.25 5.91 0.42 4.25 0.87 1.67 0.58 0.39 0.29 0.85 0.31 0.92 3.91 7.07 2.56 0.23 11.18 3.13 0.41 0.54 2.37 0.36 0.40 0.53 0.17 3.64 4.24 6.64 5.37 6.07 7.65 1.56 2.17 0.33 5.27 0.39 0.25
1. 08 3.21 4.35 3.49 3.01 1.50 0.33 3.73 3.25 3.30 0.31 3.54 2.83 3.36 4.73 3.61 0.57 5.16 0.16 0.56 0.70 29 o o 76 175 354 174 359 178 5

21 177 166 175 174 26 25 27 24 81 28 87 27 65 49 73 78 73 82 29 357 177 76 358 21 111 114 28 94 75 97 94 27 25 177 168 178 179 122 148 58 2

TEA P 3 TWD 11 P 3 TWD 15 2

VOL 1

DNT 1

DNT 1

DNT 1

DNT 1

DNT 1

DNT 2

TEA 1

DNT 1

DNT 1

DNT 1

DNT 2

TEA 2

TEA 2

TEA 2

TEA P 3 TWD 11 2

TEA P 3 TWD 20 2

TEA P 3 TWD 14 P 3 TWD 10 2

VOL P 3 TWD 19 2

VOL P 3 TWD 21 2

TEA 1

DNT 1

DNT 2

VOL 1

DNT 2

TEA P 3 TWD 10 P 3 TWD 13 2

TEA P 3 TWD 9 P 3 TWD 10 P 3 TWD 13 2

VOL 2

TEA 2

TEA 1

DNT 1

DNT 1

DNT 1

DNT 1

DNT 1

DNT P 3 TWD 7 2

TEA 30 103 p 41 P

35 2

29 2

28 2

32 2

26 2

26 2

67 3 TWD 9 3 TWD 6 TEA TEA TEA TEA TEA TEA P 3 TWD 8 2

TEA 28 24 31 2

2 TEA TEA o

30 P 3 TWD 7 2

TEA 26 2

TEA 39 28 34 2

2 2

o P

29 2

94 2

o P

162 2 TEA TEA TEA 3 TWD 8 TEA VOL 3 TWD 7 VOL UTE 010 009 013 008 008 UTE LTE LTE 008 UTE UTE 009 LTE 008 UTE UTE UTE UTE 008 UTE 009 UTE 009 009 011 009 010 009 UTE 009 001 007 009 UTE 008 009 UTE 008 009 009 011 UTE UTE UTE LTE LTE UTE 011 011 009 UTE 009 009 UTE UTE UTE UTE UTE UTE 009 UTE UTE UTE 009 UTE UTE UTE UTE UTE 007 UTE 013 007 014

-0.14

-0.68

-0.66

+1.10

-0.13

+0.58

-11.21

+11. 00

+10.26

+0.30

-0.09

-10.74

-0.50

+10.13

+0.52

-0.34

-0.30

-0.29

-0.20

+0.53

-0.22

-0.38

-0.18

-0.63

+0.66

+1.12

-0.72

-0.56

-0.65

-0.16

+0.52

+17.86

-0.66

+0.38

-0.25

+0.66

-0.68

-0.16

+0.57

-0.72

-0.72

+1.34

-0.17

-0.25

-11.44

+11.05

+12.01

-11. 42

+7.48

+8.09

+0.77

-0.18

+0.73

-0.73

-0.21

-0.20

-0.15

-0.23

-0.25

-0.21

-0.55

-0.19

-0.20

-0.21

-0.55

-0.17

-0.29

-0.24

-0.17

-0.31

+0.55

-0.19

+1.22

+0.70

+0.90 05/02/02 13:31:11 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE 010 010 WAR 009 009 WAR 013 013 008 008 008 008 UTE UTE LTE LTE LTE LTE 008 008 UTE UTE UTE UTE 009 009 LTE LTE 008 008 UTE UTE UTE UTE UTE UTE UTE UTE 008 008 WAR UTE UTE 009 009 WAR UTE UTE 009 009 WAR 009 009 WAR 011 011 009 009 WAR 010 010 009 009 WAR UTE UTE 009 009 001 001 007 007 009 009 UTE UTE 008 008 WAR 009 009 WAR UTE UTE 008 008 WAR 009 009 WAR 009 009 WAR 011 011 UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE UTE UTE 011 011 011 Oll 009 009 WAR UTE UTE 009 009 WAR 009 009 WAR UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 009 WAR UTE UTE UTE UTE UTE UTE 009 009 WAR UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 007 007 WAR UTE UTE 013 013 007 007 WAR 014 014 2058 4018 4018 4016 4082 4082 4016 4016 4016 4082 2058 4016 4016 4016 4082 2057 2057 2057 2058 4076 2085 4076 2084 4076 4076 4076 4076 4076 4076 2084 4076 4076 4076 4076 2085 4068 4068 2084 4068 4068 4068 4068 2084 2085 4104 4037 4037 4040 4019 4019 4019 2062 4019 4019 2062 2062 2061 2062 2061 2062 4019 2061 2062 2061 4019 2062 2061 2061 2062 2061 4018 2062 4018 4018 4016 INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET OUTLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 147 of 155 PROBE 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460SI 460HR 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460SI 460SI 460SI

Framatome ANP Inc.

05/02/02 13:31:13 Customer Name: Oconee Unit 1 Component: S/G B Page 14 8 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============
===

6.54 28 2

TEA UTE

-0.20 UTE UTE 2062 INLET 460HR 140 68 5.06 26 2

TEA UTE

-0.32 UTE UTE 2057 INLET 460HR 140 69 4.39 24 2

TEA UTE

-0.19 UTE UTE 2058 INLET 460HR 140 70 2.91 27 2

TEA UTE

-0.34 UTE UTE 2057 INLET 460HR 140 71 2.70 24 2

TEA UTE

-0.15 UTE UTE 2058 INLET 460HR 141 4 3.24 36 2

TEA UTE

-0.21 UTE UTE 2084 INLET 460HR 141 5 2.09 30 2

TEA UTE

-0.17 UTE UTE 2084 INLET 460HR 141 6 4.78 26 2

TEA UTE

-0.20 UTE UTE 2085 INLET 460HR 141 7 0.95 101 P 3 TWO 21 009

-0.67 009 009 WAR 4076 OUTLET 460SI 6.25 27 2

TEA UTE

-0.23 UTE UTE 2084 INLET 460HR 141 8 0.27 141 P 3 TWO 7 009

-0.75 009 009 WAR 4076 OUTLET 460SI 4.17 30 2

TEA UTE

-0.19 UTE UTE 2085 INLET 460HR 141 12 2.18 349 1 ONT LTS

-9.93 LTS LT8 4076 OUTLET 46081 141 13 0.30 70 P 3 TWD 8 008

-0.65 008 008 WAR 4076 OUTLET 460SI 18.53 181 1 DNT 009

+0.53 009 009 4076 OUTLET 460SI 141 14 3.64 33 2

TEA UTE

-0.20 UTE UTE 2084 INLET 460HR 141 19 0.57 82 P 3 TWD 14 009

-0.77 009 009 WAR 4068 OUTLET 460SI 141 20 0.30 87 P 3 TWD 8 009

-0.69 009 009 WAR 4068 OUTLET 460SI 141 21 0.41 78 P 3 TWD 10 009

-0.77 009 009 WAR 4068 OUTLET 460SI 141 22 3.66 29 2

TEA UTE

-0.28 UTE UTE 2084 INLET 460HR 141 23 0.47 88 P 3 TWD 11 009

-0.71 009 009 WAR 4068 OUTLET 460SI 2.44 23 2

TEA UTE

-0.27 UTE UTE 2085 INLET 460HR 141 24 4.69 28 2

TEA UTE

-0.26 UTE UTE 2084 INLET 460HR 141 25 4.60 28 2

TEA UTE

-0.23 UTE UTE 2085 INLET 460HR 141 26 6.51 28 2

TEA UTE

-0.19 UTE UTE 2084 INLET 460HR 141 27 4.88 25 2

TEA UTE

-0.28 UTE UTE 2085 INLET 460HR 141 28

1. 96 22 2

TEA UTE

-0.25 UTE UTE 2084 INLET 460HR 141 29 2.37 18 2

TEA UTE

-0.19 UTE UTE 2085 INLET 460HR 141 33 9.27 178 1 DNT UTE

-11. 45 UTE UTE 4104 OUTLET 460SI 3.37 23 2

TEA UTE

-0.12 UTE UTE 2084 INLET 460HR

1. 82 158 1 DNT LTE

+10.95 LTE LTE 4037 INLET 46081 141 36

1. 65 23 2

TEA UTE

-0.19 UTE UTE 2062 INLET 460HR 141 38 3.15 31 2

TEA UTE

-0.25 UTE UTE 2061 INLET 460HR 141 39 0.59 85 P 3 TWD 13 009

+0.69 009 009 WAR 4019 INLET 460SI 3.13 27 2

TEA UTE

-0.18 UTE UTE 2062 INLET 460HR 141 40

1. 40 42 2

TEA UTE

-0.17 UTE UTE 2061 INLET 460HR 141 42 2.74 37 2

TEA UTE

-0.29 UTE UTE 2061 INLF;T 460HR 141 43 0.33 83 P 3 TWD 8 009

-0.64 009 009 WAR 4019 INLET 460SI

1. 35 21 2

TEA UTE

-0.13 UTE UTE 2062 INLET 460HR 141 44 2.47 24 2

TEA UTE

-0.18 UTE UTE 2061 INLET 460HR 141 45 2.28 31 2

TEA UTE

-0.20 UTE UTE 2062 INLET 460HR 141 46 0.43 80 P 3 TWO 10 009

-0.50 009 009 WAR 4019 INLET 460SI 0.61 100 P 3 TWD 13 009

+0.68 009 009 WAR 4019 INLET 460SI 0.38 95 P 3 TWD 9 008

+0.57 008 008 WAR 4019 INLET 46081 4.15 36 2

TEA UTE

-0.25 UTE UTE 2061 INLET 460HR 141 47 4.20 30 2

TEA UTE

-0.21 UTE UTE 2062 INLET 460HR 141 48 3.75 27 2

TEA UTE

-0.20 UTE UTE 2061 INLET 460HR 141 51 0.31 104 P 3 TWD 7 010

-0.72 010 010 WAR 4019 INLET 460SI 0.22 68 P 3 TWD 5 007

+0.55 007 007 WAR 4019 INLET 460SI 0.23 134 P 3 TWD 5 007

-0.44 007 007 WAR 4019 INLET 460SI 141 54 0.25 121 P 3 TWO 6 010

-0.72 010 010 WAR 4019 INLET 460SI 0.40 102 P 3 TWD 9 008

-0.08 008 008 WAR 4019 INLET 460SI 141 57 0.37 64 P 3 TWD 8 009

+0.11 009 009 WAR 4019 INLET 460SI 0.33 48 P 3 TWO 7 009

+0.67 009 009 WAR 4019 INLET 460SI 141 60 1.96 149 1 DNT LT8

-1. 99 LTS LTS 4082 OUTLET 460SI 2.24 27 2

TEA UTE

-0.25 UTE UTE 2061 INLET 460HR 141 62 2.42 35 2

TEA UTE

-0.31 UTE UTE 2061 INLET 460HR 141 64 6.69 30 2

TWD 89 UTE

-0.46 UTE UTE 2061 INLET 460HR 6.63 30 2

MAl UTE

-0.46 UTE UTE CL 2061 INLET 460HR 0.46 67 2

VOL 014

+1. 35 014 014 4018 INLET 460SI 0.11 79 9

PLP 014

+1. 24 014 014 4018 INLET 46081 141 66 3.52 32 2

TEA UTE

-0.32 UTE UTE 2061 INLET 460HR 141 67 4.87 27 2

TEA UTE

-0.19 UTE UTE 2062 INLET 460HR 141 68 0.40 160 P 3 TWD 6 009

-0.50 009 009 WAR 4026 INLET 460SI 142 1 0.28 146 P 3 TWO 7 008

+0.49 008 008 WAR 4076 OUTLET 460SI

11. 81 181 1 ONT 010

+0.19 010 010 4076 OUTLET 460SI 4.11 33 2

TEA UTE

-0.17 UTE UTE 2084 INLET 460HR 142 3 0.13 77 2

VOL 006

+6.50 006 006 4076 OUTLET 460SI 0.08 55 2

VOL 006

+7.05 006 006 4076 OUTLET 460SI 3.62 30 2

TEA UTE

-0.14 UTE UTE 2084 INLET 460HR 142 4 0.57 102 P 3 TWD 14 009

+0.35 009 009 WAR 4076 OUTLET 460S1 142 5 4.60 31 2

TEA UTE

-0.16 UTE UTE 2084 INLET 460HR 142 7 5.63 177 1 ONT LTE

+11.26 LTE LTE 4076 OUTLET 460S1 3.59 4

1 ONT UTE

-11.59 UTE UTE 4076 OUTLET 460SI 5.67 29 2

TEA UTE

-0.12 UTE UTE 2084 INLET 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLU8 POINT QUERY: QueryMl ROW TUBE VOLT8 OEG CHN INO %TW LOCATION 142 8 142 9 142 11 142 12 142 13 142 18 142 21 142 22 142 24 142 25 142 26 142 27 142 28 142 30 142 31 142 32 142. 33 142 34 142 36 142 38 142 40 142 41 142 45 142 46 142 47 142 48 142 49 142 53 142 54 142 55 142 57 142 58 142 59 142 60 142 61 142 63 143 1 143 2 5.04 0.74 6.31 4.31 1.08 5.84 16.11 4.1l 0.44 0.41 8.06 0.47 0.51 7.71 0.47 0.69 0.48 0.31 2.34

1. 65 3.39 2.96 4.87 2.07 8.25 0.20 1.22 1.87
1. 83 2.09
1. 80 1.89
1. 40 0.16 4.15 2.20 2.58 0.81 0.81
1. 54 5.87 2.43 0.23 2.53 2.55 4.57 2.65 2.18 0.39 0.31 0.19 2.66 0.49 0.36 7.78 0.29 3.38 0.25 2.32 0.39 0.23 3.96 2.08 0.33 5.30 4.65 2.26 0.38 4.92 2.87 0.20 14.00 0.63 16.58 2.88 357 1 DNT LTE 82 P 3 TWO 17 009 359 1 DNT UTE 22 2

TEA UTE 94 P 3 TWO 23 009 29 2

TEA UTE 179 1 DNT 009 34 2

TEA UTE 121 P 3 TWO 11 005 94 P 3 TWD 10 007 177 1 DNT 009 126 2 VOL 009 106 P 3 TWD 13 007 177 1 DNT 009 101 2 VOL UTS 65 P 3 TWD 16 009 118 P 3 TWD 12 009 111 P 3 TWD 8 009 23 2

TEA UTE 24 2

TEA UTE 28 2

TEA UTE 33 2

TEA UTE 30 2

TEA UTE 32 P 1 8CI UTE 35 2

TEA UTE 111 P 3 TWO 0 UTE 19 P 3 TWO 80 UTE 17 P 3 TWO 99 UTE 18 P 3 TWD 98 UTE 22 P 3 TWD 100 UTE 28 P 3 TWD 97 UTE 31 P 3 TWD 100 UTE 32 P 3 TWD 86 UTE 82 P 3 TWO 0 UTE 26 2

TEA UTE 19 2

TEA UTE 25 2

TEA UTE 24 2

SAl UTE 24 2

TWO 74 UTE 32 2

TEA UTE 27 2

TEA UTE 24 2

TEA UTE 32 P 3 TWO 5 009 29 2

TEA UTE 25 2

TEA UTE 30 2

TEA UTE 26 2

TEA UTE 348 1 DNT 010 95 P 3 TWO 8 010 148 P 3 TWO 6 010 77 P 3 TWO 4 006 33 2

TEA UTE 64 P 3 TWO 11 010 99 P 3 TWO 8 009 29 2

TEA UTE 139 P 3 TWD 7 007 27 2

TEA UTE 104 P 3 TWO 6 010 28 2

TEA UTE 146 P 3 TWO 8 010 125 P 3 TWD 5 010 28 2

TEA UTE 29 2

TEA UTE 81 P 3 TWO 8 009 24 2

TEA UTE 31 2

TEA UTE 30 2

TEA UTE 73 2

VOL 013 28 2

TEA UTE 29 2

TEA UTE 71 2

VOL 003 176 1 ONT 010 121 P 3 TWD 11 009 177 1 ONT 010 22 2

TEA UTE

+11.27

-0.64

-11.89

-0.26

-0.66

-0.17

+0.46

-0.14

-0.14

-0.72

-0.33

+0.75

-0.72

-0.51

-1. 06

-0.68

-0.77

-0.73

-0.24

-0.25

-0.20

-0.27

-0.13

-0.31

-0.23

-0.31

-0.31

-0.31

-0.31

-0.31

-0.31

-0.31

-0.31

-0.31

-0.26

-0.18

-0.28

-4.13

-4.13

-0.25

-0.20

-0.28

-0.70

-0.41

-0.20

-0.22

-0.31

+3.82

-0.68

-0.72

+0.33

-0.25

-0.75

+0.59

-0.15

-0.56

-0.22

-0.72

-0.20

-0.70

-0.66

-0.20

-0.33

+0.56

-0.32

-0.20

-0.30

+0.78

-0.21

-0.38

+0.99

+0.09

-0.54

-0.06

-0.18 TO+13.3 TO+22.2 TO+31.1 TO+40.0 TO+48.9 TO+57.8 TO+66.7 TO+75.6 TO+84.4 05/02/02 13:31:15 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG LTE LTE 009 009 UTE UTE UTE UTE 009 009 UTE UTE 009 009 UTE UTE 005 005 007 007 009 009 009 009 007 007 009 009 UTS UTS 009 009 009 009 009 009 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTE UTS UTE UTE UTE UTE UTE UTE 009 009 UTE UTE UTE UTE UTE UTE UTE UTE 010 010 010 010 010 010 006 006 UTE UTE 010 010 009 009 UTE UTE 007 007 UTE UTE 010 010 UTE UTE 010 010 010 010 UTE UTE UTE UTE 009 009 UTE UTE UTE UTE UTE UTE 013 013 UTE UTE UTE UTE 003 003 010 010 009 009 010 010 UTE UTE WAR WAR WAR WAR WAR WAR WAR WAR CS TR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 4076 4076 4076 2085 4076 2084 4076 2084 4076 4076 4076 4076 4076 4076 4076 4068 4068 4068 2085 2085 2084 2085 2084 2085 2085 2085 2085 2085 2085 2085 2085 2085 2085 2085 2085 2084 2085 2084 2084 2061 2062 2061 4019 2061 2062 2062 2061 4019 4019 4019 4019 2061 4019 4019 2062 4019 2061 4019 2061 4019 4019 2062 2061 4019 2061 2062 2061 4019 2062 2061 4018 4078 4078 4078 2085 OUTLET OUTLET OUTLET INLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET Page 149 of 155 PROBE 46081 46081 460SI 460HR 460S1 460HR 460SI 460HR 46081 460SI 460S1 46081 46081 46081 460SI 460SI 46081 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 46081 460SI 460S1 460S1 460HR 460SI 460SI 460HR 460S1 460HR 46081 460HR 46081 46081 460HR 460HR 460S1 460HR 460HR 460HR 460S1 460HR 460HR 460S1 46081 46081 460S1 460HR

Framatome ANP Inc.

05/02/02 13:31:17 Customer Name: Oconee Unit 1 Component: S/G B Page 150 of 155 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -: MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLT8 OEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

============

==============;::::;:

143 3 7.05 167 1 ONT 010

-0.58 010 010 4078 OUTLET 460SI 143 4 7.28 171 1 ONT LTE

+11. 62 LTE LTE 4078 OUTLET 460SI 8.25 170 1 ONT UTE

-11. 93 UTE UTE 4078 OUTLET 460SI 5.07 25 2

TEA UTE

-0.25 UTE UTE 2085 INLET 460HR 143 8 3.21 24 2

TEA UTE

-0.12 UTE UTE 2084 INLET 460HR 143 9 0.34 74 P 3 TWO 6 008

-0.62 008 008 WAR 4078 OUTLET 46081

11. 87 177 1 ONT 009

+0.45 009 009 4078 OUTLET 460SI 0.18 100 2 VOL 014

+0.85 014 014 4078 OUTLET 460SI 5.05 167 1 ONT 015

+2.36 015 015 4078 OUTLET 460SI 143 10 0.35 43 2

VOL 008

+0.75 008 008 4078 OUTLET 460SI 9.83 185 1 ONT 009

-0.31 009 009 4078 OUTLET 46081 143 15 0.28 70 P 3 TWO 7 009

-0.73 009 009 WAR 4068 OUTLET 460SI 0.23 90 P 3 TWO 6 010

+0.49 010 010 WAR 4068 OUTLET 460SI 4.09 33 2

TEA UTE

-0.10 UTE UTE 2084 INLET 460HR 143 16

1. 07 85 P 3 TWO 23 009

-0.74 009 009 WAR 4068 OUTLET 46081 5.18 30 2

TEA UTE

-0.13 UTE UTE 2084 INLET 460HR 143 17

1. 80 63 P 3 TWO 31 009

-0.64 009 009 WAR 4068 OUTLET 46081 143 19 0.16 118 2 VOL 007

+1.15 007 007 4068 OUTLET 46081 2.18 30 2

TEA UTE

-0.21 UTE UTE 2084 INLET 460HR 143 21 3.86 25 2

TEA UTE

-0.28 UTE UTE 2085 INLET 460HR 143 23 6.20 24 2

TEA UTE

-0.19 UTE UTE 2085 INLET 460HR 143 25 0.13 63 P 3 TWO 3 009

+0.59 009 009 WAR 4061 OUTLET 46081 3.17 32 2

TEA UTE

-0.11 UTE UTE 2084 INLET 460HR 143 26 0.34 119 2 VOL 009

+0.35 009 009 4065 OUTLET 460SI 5.20 28 2

TEA UTE

-0.19 UTE UTE 2084 INLET 460HR 143 27

1. 62 20 2

TEA UTE

-0.21 UTE UTE 2085 INLET 460HR 143 28 6.17 32 2

TEA UTE

-0.16 UTE UTE 2084 INLET 460HR 0.33 31 P 3 TWO 9 007

+0.62 007 007 WAR 4037 INLET 46081 143 29 0.45 57 P 3 TWO 12 012

-0.78 012 012 WAR 4037 INLET 46081 0.60 59 P 3 TWO 15 011

+0.73 011 011 WAR 4037 INLET 460SI 143 31 3.44 27 2

TEA UTE

-0.27 UTE UTE 2085 INLET 460HR 0.12 47 2

VOL 011

+1.28 011 011 4037 INLET 460SI 143 32 3.01 34 2

TEA UTE

-0.30 UTE UTE 2061 INLET 460HR 143 35 4.80 29 2

TEA UTE

-0.23 UTE UTE 2061 INLET 460HR 143 36 0.26 87 P 3 TWO 6 009

+0.71 009 009 WAR 4019 INLET 46081 5.60 28 2

TEA UTE

-0.21 UTE UTE 2062 INLET 460HR 143 37 0.46 48 P 3 TWO 10 009

-0.65 009 009 WAR 4019 INLET 460SI 0.16 40 P 3 TWD 4 009

+0.71 009 009 WAR 4019 INLET 46081 3.15 32 2

TEA UTE

-0.17 UTE UTE 2061 INLET 460HR 143 39 3.26 28 2

TEA UTE

-0.23 UTE UTE 2061 INLET 460HR 143 40 0.29 100 P 3 TWD 7 010

-0.70 010 010 WAR 4019 INLET 46081 143 42 0.56 58 P 3 TWD 11 008

-0.68 008 008 WAR 4019 INLET 46081 8.48 174 1 ONT 009

+0.68 009 009 4082 OUTLET 46081 143 43 0.41 85 P 3 TWD 9 009

+0.73 009 009 WAR 4019 INLET 46081 1.48 25 2

TEA UTE

-0.30 UTE UTE 2061 INLET 460HR 143 44 4.86 30 2

TEA UTE

-0.23 UTE UTE 2062 INLET 460HR 143 45 0.44 101 P 3 TWD 10 010

-0.68 010 010 WAR 4019 INLET 46081 0.18 66 P 3 TWD 4 009

-0.44 009 009 WAR 4019 INLET 460SI

1. 70 28 2

TEA UTE

-0.27 UTE UTE 2061 INLET 460HR 143 48 4.63 176 1 ONT 010

-0.60 010 010 4019 INLET 46081 3.04 30 2

TEA UTE

-0.25 UTE UTE 2061 INLET 460HR 143 51 0.23 57 P 3 TWD 5 009

+0.76 009 009 WAR 4019 INLET 460SI 1.12 28 2

TEA UTE

-0.27 UTE UTE 2061 INLET 460HR 143 53 3.84 28 2

TEA UTE

-0.27 UTE UTE 2061 INLET 460HR 143 55 0.34 69 P 3 TWD 8 010

-0.73 010 010 WAR 4019 INLET 460SI 2.73 30 2

TEA UTE

-0.30 UTE UTE 2061 INLET 460HR 143 56 0.63 81 2

VOL 007

+1.13 007 007 4019 INLET 46081 0.12 117 2 VOL 007

+0.83 007 007 4019 INLET 46081 5.44 28 2

TEA UTE

-0.35 UTE UTE 2061 INLET 460HR 143 57 4.31 31 2

TEA UTE

-0.19 UTE UTE 2062 INLET 460HR 143 58 2.81 30 2

TEA UTE

-0.32 UTE UTE 2061 INLET 460HR 143 59 5.11 28 2

TEA UTE

-0.22 UTE UTE 2062 INLET 460HR 143 60 2.43 28 2

TEA UTE

-0.35 UTE UTE 2061 INLET 460HR 0.90 105 P 3 TWD 17 009

+0.65 009 009 WAR 4026 INLET 460SI 143 61 3.26 18 2

TEA UTE

-0.23 UTE UTE 2062 INLET 460HR 0.40 52 P 3 TWO 8 010

-0.65 010 010 WAR 4026 INLET 460SI 144 1 0.50 66 P 3 TWD 9 006

+0.46 006 006 WAR 4078 OUTLET 46081 10.75 165 1 ONT 010

+0.09 010 010 4078 OUTLET 46081 0.73 26 2

TEA UTE

-0.23 UTE UTE 2084 INLET 460HR 144 3 4.15 172 1 ONT LTE

+11. 58 LTE LTE 4078 OUTLET 46081 3.60 179 1 ONT LTE

+10.87 LTE LTE 4078 OUTLET 46081 3.62 168 1 ONT UTE

-12.94 UTE UTE 4078 OUTLET 46081 5.73 165 1 ONT UTE

-11.47 UTE UTE 4078 OUTLET 46081 4.02 165 1 DNT UTE

-9.27 UTE UTE 4078 OUTLET 460SI 5.57 27 2

TEA UTE

-0.16 UTE UTE 2084 INLET 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS

~ MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS OEG CHN INO %TW LOCATION 144 4 144 6 144 7 144 8 144 9 144 10 144 11 144 12 144 15 144 16 144 17 144 18 144 19 144 20 144 22 144 24 144 26 144 27 144 32 144 33 144 34 144 36 144 37 144 38 144 39 144 40 144 41 144 42 144 45 144 46 144 47 144 50 144 51 144 52 144 53 144 55 144 56 144 57 145 1 145 2 6.02 0.14 5.41 4.12 0.58 0.39 0.42 2.37 5.03 13.52 0.47 0.31 0.29 7.84

1. 41 5.36 8.60 4.12 0.62 2.39 5.28 2.05 3.21
1. 85 0.34
1. 45 5.15 0.83 0.42 4.51 3.13 3.03 3.83 0.12 0.08 4.54 2.09 1.35 2.37 1.68 0.39 3.13 4.41 0.35 0.20 5.23 0.27 0.38 3.09 6.13 0.36 5.76 0.19 0.32 0.43 0.20 3.64 2.60 0.41 4.53 3.93 0.44 0.17 5.39 3.18 0.63 4.26 0.47 0.31 5.75 18.89 0.20 0.53
1. 85 0.67 ONT VOL ONT TEA 177 1 73 2

174 1 23 2

66 P 3 TWO 10 P 3 TWO 7 77 3 TWO 12 TEA DNT DNT 67 P

34 2

166 1 175 1 88 P 3 TWO 8 P 3 TWO 6 P 3 TWO 5 1

DNT 61 49 180 21 24 359 29 87 34 28 26 29 38 94 25 28 67 145 174 26 28 29 92 76 25 118 34 31 27 59 32 27 71 55 25 92 76 28 181 105 24 77 71 76 106 33 26 73 28 30 123 96 28 33 70 26 148 46 28 176 65 98 23 19 2

TEA 2

TEA 1

ONT 2

TEA P 3 TWD 15 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA P 4 TWO 9 2

TEA 2

TEA P 3 TWD 14 P 3 TWO 9 1

ONT 2

TEA 2

TEA 2

TEA 2

VOL 2

VOL 2

TEA 1

VOL 2

TEA 2

TEA 2

TEA P 3 TWD 8 2

TEA 2

TEA P 3 TWD 8 P 3 TWD 5 2

TEA P 3 TWO 6 P 3 TWD 9 2

TEA 1

DNT P 3 TWO 8 2

TEA 2

VOL P 3 TWO 7 P 3 TWO 10 P 3 TWO 5 2

TEA 2

TEA P 3 TWO 9 2

TEA 2

TEA P 3 TWO 10 2

VOL 2

TEA 2

TEA P 3 TWO 13 2

TEA P 3 TWD 10 P 3 TWO 6 2

TEA 1

DNT 2

VOL P 3 TWO 10 2

TEA 2

MAl LTE 007 UTE UTE 009 009 009 UTE 009 009 010 006 007 009 UTE UTE 008 UTE 010 UTE UTE UTE UTE UTE 009 UTE UTE 011 015 003 UTE UTE UTE 014 014 UTE UTE UTE UTE UTE 008 UTE UTE 009 009 UTE 009 009 UTE 010 008 UTE 012 009 009 008 UTE UTE 009 UTE UTE 010 007 UTE UTE 009 UTE 010 009 UTE 010 007 010 UTE UTE

+11. 25

+1. 59

-11.29

-0.23

+0.75

-0.41

-0.69

-0.17

+0.41

-0.28

-0.46

-0.75

-0.66

-0.42

-0.16

-0.27

+0.32

-0.18

-0.86

-0.19

-0.28

-0.17

-0.21

-0.18

-0.71

-0.21

-0.18

+0.69

-0.64

+12.34

-0.25

-0.20

-0.26

+0.94

+1.12

-0.12

-6.15

-0.26

-0.19

-0.31

-0.63

-0.16

-0.29

+0.71

-0.59

-0.17

-0.11

+0.66

-0.31

-0.60

+0.67

-0.19

+0.87

-0.47

+0.64

+0.73

-0.39

-0.36

-0.68

-0.22

-0.29

-0.69

+1.25

-0.23

-0.39

-0.25

-0.26

-0.70

+0.70

-0.19

-0.53

+1.05

-0.58

-0.25

-1.09 05/02/02 13:31:19 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG LTE LTE 007 007 UTE UTE UTE UTE 009 009 WAR 009 009 WAR 009 009 WAR UTE UTE 009 009 009 009 010 010 WAR 006 006 WAR 007 007 WAR 009 009 UTE UTE UTE UTE 008 008 UTE UTE 010 010 WAR UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 009 WAR UTE UTE UTE UTE 011 011 WAR 015 015 WAR 003 003 UTE UTE UTE UTE UTE UTE 014 014 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 008 008 WAR UTE UTE UTE UTE 009 009 WAR 009 009 WAR UTE UTE 009 009 WAR 009 009 WAR UTE UTE 010 010 008 008 WAR UTE UTE 012 012 009 009 WAR 009 009 WAR 008 008 l<!AR UTE UTE UTE UTE 009 009 WAR UTE UTE UTE UTE 010 010 WAR 007 007 UTE UTE UTE UTE 009 009 WAR UTE UTE 010 010 WAR 009 009 WAR UTE UTE 010 010 007 007 010 010 WAR UTE UTE UTE UTE CS 4078 4078 4078 2085 4078 4078 4078 2084 4078 4078 4078 4078 4078 4078 2084 2085 4068 2084 4068 2084 2085 2084 2085 2084 4065 2084 2084 4078 4104 4078 2085 2062 2061 4019 4019 2062 4019 2061 2062 2061 4019 2062 2061 4019 4019 2062 4019 4019 2061 4019 4019 2062 4019 4019 4019 4019 2061 2061 4019 2062 2061 4019 4019 2062 2061 4026 2061 4026 4026 2062 4079 4079 4079 2085 2085 OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET OUTLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET Page 151 of 155 PROBE 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460HR 460SI 460SI 460SI 460HR 460HR 460HR 460SI 460SI 460HR 460SI 460HR 460HR 460HR 460SI 460HR 460HR 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460HR 460HR 460SI 460SI 460HR 460HR 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460HR 460HR

Frarnatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS - MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS OEG CHN INO %TW LOCATION 145 4 145 5 145 6 145 8 145 10 145 12 145 24 145 26 145 27 145 28 145 29 145 35 145 38 145 40 145 41 145 42 145 43 145 45 145 46 145 47 145 50 146 1 146 2 146 3 146 4 1466 146 7 146 8 146 9 146 10 146 11 146 13 146 15 146 16 146 18 146 19 146 20 146 23 146 24 146 25 0.67 1.11 0.57 4.87 0.68 0.59 8.41 1.14

11. 47 3.29 6.12 3.50 0.64 0.81 6.45 5.18 5.24 5.54 5.02 5.74 2.34 4.26 0.31 0.15 0.12 3.13 0.21 0.34 8.55 0.37 0.28 0.40 0.21 2.98 3.59 4.03 0.21 0.28 0.33 0.37 0.24 0.09 0.05 0.30 4.35 0.61 0.69 0.56 4.28 1.17 3.22 0.29 3.46 0.67 0.08 3.01 0.35 1.24 2.05 10.67 10.33 0.60 0.39 3.23 7.38 3.64 0.71 0.19 2.10 0.46 0.96 0.38 5.13 5.67 5.85 19 2

TWO 25 UTE 22 2

TWO 35 UTE 96 P 3 TWO 10 009 29 2

TEA UTE 86 P 3 TWO 12 010 68 P 3 TWO 10 008 182 1 ONT 009 20 2

TEA UTE 177 1 ONT 009 24 2

TEA UTE 167 1 ONT 009 30 2

TEA UTE 86 P 3 TWO 11 009 76 P 3 TWO 14 011 169 1 ONT LTE 176 1 ONT LTE 169 1 ONT LTE 165 1 ONT LTE 165 1 ONT LTE 168 1 ONT UTE 19 2

TEA UTE 169 1 ONT UTE 64 2

VOL 010 34 P 3 TWO 3 009 102 2 VOL 006 4

1 ONT LTE 40 P 3 TWO 5 008 35 P 3 TWO 7 009 182 1 ONT 009 71 P 3 TWO 8 008 86 P 3 TWO 6 010 35 P 3 TWO 9 010 45 P 3 TWO 5 009 356 1 ONT 010 180 1 ONT 010 181 1 ONT 010 83 P 3 TWO 5 009 62 P 3 TWO 7 009 105 P 3 TWO 8 009 82 9

PLP 013 78 9

PLP 013 91 2

VOL 006 80 2

VOL 006 98 P 3 TWO 7 009 26 2

TEA UTE 26 P 3 TWD 11 010 43 P 3 TWO 12 010 83 P 3 TWO 10 010 28 2

TEA UTE 22 2

TEA UTE 28 2

TEA UTE 81 2

VOL UTS 28 2

TEA UTE 26 P 3 TWO 15 009 86 2

VOL 014 25 2

TEA UTE 49 P 3 TWO 8 007 23 2

TEA UTE 28 2

TEA UTE 173 1 ONT 009 179 1 ONT 009 69 P 3 TWO 14 008 108 P 3 TWO 9 008 31 2

TEA UTE 160 1 ONT 009 32 2

TEA UTE 148 P 3 TWO 15 008 56 2

VOL 012 37 2

TEA UTE 62 P 3 TWO 11 009 23 2

TEA UTE 76 P 3 TWO 9 010 28 2

TEA UTE 163 1 ONT LTE 179 1 ONT UTS

-1. 09

-1. 28

-0.21

-0.17

-0.70

+0.20

-0.03

-0.12

-0.49

-0.18

-0.52

-0.26

-0.67

-0.69

+1.19

+1.92

+3.05

+4.44

+11. 37

-11. 95

-0.17

-12.84

-0.71

-0.47

+1. 48

+11.49

+0.25

-0.64

+0.52

-0.60

-0.75

-0.72

-0.62

-0.43

-0.54

-0.32

-0.64

+0.66

+0.58

+1.16

+1. 57

+13.65

+10.40

+0.70

-0.24

+0.03

+0.69

-0.57

-0.16

-0.16

-0.17

-4.02

-0.25

+0.48

+1.37

-0.16

-0.73

-0.18

-0.30

-0.03

-0.35

-0.77

-0.33

-0.26

-0.15

-0.32

-0.12

+1. 01

-0.14

-0.27

-0.22

+0.64

-0.17

+11. 47

+11. 77 05/02/02 13:31:21 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE 009 009 WAR UTE UTE 010 010 WAR 008 008 WAR 009 009 UTE UTE 009 009 UTE UTE 009 009 UTE UTE 009 009 WAR 011 011 WAR LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE 010 010 009 009 WAR 006 006 LTE LTE 008 008 WAR 009 009 WAR 009 009 008 008 WAR 010 010 WAR 010 010 WAR 009 009 WAR 010 010 010 010 010 010 009 009 WAR 009 009 WAR 009 009 WAR 013 013 013 013 006 006 006 006 009 009 WAR UTE UTE 010 010 WAR 010 010 WAR 010 010 WAR UTE UTE UTE UTE UTE UTE UTS UTS UTE UTE 009 009 WAR 014 014 UTE UTE 007 007 WAR UTE UTE UTE UTE 009 009 009 009 008 008 WAR 008 008 WAR UTE UTE 009 009 UTE UTE 008 008 WAR 012 012 UTE UTE 009 009 WAR UTE UTE 010 010 WAR UTE UTE LTE LTE UTS UTS 2085 2085 4078 2084 4078 4078 4078 2084 4078 2084 4078 2085 4078 4078 4078 4078 4078 4078 4078 4078 2084 4019 4019 4019 4019 4019 4019 4019 4019 4019 4019 4019 4019 4082 4082 4019 4019 4019 4019 4019 4019 4019 4019 4019 2085 4079 4079 4079 2084 2084 2085 4079 2085 4079 4079 2084 4079 2084 2085 4079 4079 4079 4079 2085 4079 2085 4065 4065 2084 4079 2085 4079 2084 4079 4079 INLET INLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET INLET OUTLET OUTLET INLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET OUTLET OUTLET INLET OUTLET INLET OUTLET INLET OUTLET OUTLET Page 152 of 155 PROBE 460HR 460HR 460S1 460HR 460S1 460S1 460S1 460HR 460S1 460HR 460S1 460HR 460S1 460S1 460S1 460S1 460SI 460S1 460S1 460S1 460HR 460SI 460S1 460SI 460SI 460S1 460S1 460S1 460S1 460S1 460S1 460SI 460S1 460S1 460S1 460S1 460SI 460S1 460S1 460S1 460S1 460S1 460S1 460S1 460HR 460S1 460S1 460S1 460HR 460HR 460HR 460S1 460HR 460S1 460S1 460HR 460S1 460HR 460HR 460S1 460S1 460S1 460S1 460HR 460S1 460HR 460S1 460S1 460HR 460S1 460HR 460S1 460HR 460S1 460S1

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LI8T OF IMPERFECTION8 -

MRPC/PLU8 POINT QUERY: QueryMl ROW TUBE VOLT8 DEG CHN IND %TW LOCATION 146 27 146 29 146 30 146 35 146 36 146 38 146 39 146 43 146 45.

146 47 146 51 147 1 147 2 147 3 147 7 147 9 147 11 147 12 147 13 147 14 147 15 147 16 147 20 147 21 147 23 147 24 147 26 147 28 147 29 147 30 147 31 147 32 147 33 147 34 147 37 147 38 147 40 147 41 147 42 147 43 147 45 148 2 148 3 148 4 148 5 1487 148 8 4.74 4.36 0.10 3.85 4.21 3.43 5.91 2.32 6.59 0.42 4.40 0.50 2.59 0.12

1. 80 3.08 0.16 4.16 0.67 0.26 0.09 8.10 9.20 6.22 2.52 3.33 0.39 0.27 7.33
11. 55 10.62
1. 77 7.81 3.57 2.05 1.26 3.33 4.49 3.90 6.65 3.79 3.56 0.47 2.68 3.28
1. 64 3.53 7.72
1. 54
1. 58 2.65 2.06 0.33 2.88 0.49 0.14 1.06 9.86 2.34 12.59 3.36 3.42
1. 90 8.22 0.38 3.39 6.49 0.23 0.34 3.59 5.16 3.10 0.84 4.06 6.05 TEA DNT VOL DNT DNT TEA TEA TEA ONT 28 2

182 1 79 2

189 1 182 1 31 2

24 2

28 2

169 1 90 P 3 TWD 9 2

TEA 26 116 25 P 3 TWD 10 2

TEA 76 2

VOL 28 2

TEA 30 2

TEA 92 2

VOL 2

TEA 30 117 P 102 P 76 2

172 1 171 1 177 1 22 2

32 2

55 P

82 2

25 2

178 1 177 1 29 2

168 1 26 2

15 2

31 2

30 2

167 1 154 1 179 1 180 1 31 2

64 P

27 2

27 2

164 1 30 2

170 1 25 2

173 1 28 2

26 2

91 26 106 53 28 176 26 183 2

28 42 160 70 26 180 3 TWD 10 3 TWO 6 VOL DNT DNT ONT TEA TEA 3 TWD 9 VOL TEA DNT DNT TEA DNT TEA TEA TEA TEA DNT DNT DNT DNT TEA 3 TWD 10 TEA TEA ONT TEA DNT TEA DNT TEA TEA P 3 TWO 7 2

TEA P 3 TWO 10 2

VOL 2

TEA 1

ONT 2

TEA 1

ONT 1

ONT 2

TEA 2

TEA 1

ONT P 3 TWO 9 2

TEA 1

DNT 71 P 3 60 P 3 24 2

348 1 24 2

344 1 348 1 355 1 TWO 5 TWO 8 TEA DNT TEA' DNT DNT DNT UTE UTS 006 LTE LTE UTE UTE UTE 009 009 UTE 010 UTE 007 UTE UTE 002 UTE 009 010 010 001 007 001 UTE UTE 008 014 UTE 009 009 UTE 009 UTE UTE UTE UTE LTE UTE UT8 LTE UTE 010 UTE UTE 012 UTE 009 UTE 009 UTE UTE 009 UTE 014 014 UTE 010 UTE 010 011 UTE UTE 001 010 UTE 001 009 010 UTE 001 UTE LT8 001 001

-0.30

+11.29

+1.30

+10.78

+11. 44

-0.20

-0.20

-0.30

+0.00

+0.70

-0.25

-0.67

-0.15

+0.75

-0.18

-0.30

+0.87

-0.27

+0.45

-0.67

+6.65

-0.69

-0.71

-0.77

-0.16

-0.19

+0.23

+1.14

-0.27

+0.00

-0.17

-0.23

-0.04

-0.17

-0.25

-0.21

-0.19

+11.41

-11.95

+11.26

+11.22

-0.23

+0.63

-0.30

-0.21

+17.76

-0.17

+0.00

-0.17

+0.00

-0.20

-0.19

-0.64

-0.22

+0.66

+1.27

-0.19

+0.00

-0.31

-0.24

-0.09

-0.20

-0.18

-0.66

+0.68

-0.17

-0.76

-0.60

-0.61

-0.20

-0.74

-0.23

-0.09

-0.85

-0.78 05/02/02 13:31:23 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UT8 UT8 006 006 LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE 009 009 009 009 WAR UTE UTE 010 010 WAR UTE UTE 007 007 UTE UTE UTE UTE 002 002 UTE UTE 009 009 WAR 010 010 WAR 010 010 001 001 007 007 001 001 UTE UTE UTE UTE 008 008 WAR 014 014 UTE UTE 009 009 009 009 UTE UTE 009 009 UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE UTE UTE UT8 UT8 LTE LTE UTE UTE 010 010 WAR UTE UTE UTE UTE 012 012 UTE UTE 009 009 UTE UTE 009 009 UTE UTE UTE UTE 009 009 WAR UTE UTE 014 014 WAR 014 014 UTE UTE 010 010 UTE UTE 010 010 011 011 UTE UTE UTE UTE 001 001 010 010 WAR UTE UTE 001 001 009 009 WAR 010 010 WAR UTE UTE 001 001 UTE UTE LT8 LT8 001 001 001 001 2085 4019 4019 4019 4019 2061 2062 2061 4019 4019 2061 4019 2062 4019 2062 2061 4019 2061 4026 4079 4079 4079 4079 4079 2084 2084 4079 4079 2085 4079 4079 2085 4079 2084 2085 2085 2084 4079 4079 4019 4019 2061 4019 2061 2062 4019 2062 4019 2062 4019 2061 2062 4019 2062 4019 4019 2062 4019 2061 4082 4082 2062 2080 4079 4079 2084 4079 4079 4079 2085 4082 2085 4082 4082 4082 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET Page 153 of 155 PROBE 460HR 46081 46081 46081 46081 460HR 460HR 460HR 460SI 46081 460HR 46081 460HR 46081 460HR 460HR 460SI 460HR 460SI 460SI 460SI 46081 46081 46081 460HR 460HR 46081 46081 460HR 460SI 460SI 460HR 46081 460HR 460HR 460HR 460HR 46081 46081 46081 46081 460HR 46081 460HR 460HR 460SI 460HR 46081 460HR 46081 460HR 460HR 46081 460HR 46081 46081 460HR 46081 460HR 46081 46081 460HR 460HR 460SI 46081 460HR 460SI 46081 46081 460HR 460SI 460HR 46031 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 1 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION 148 11 148 13 148 14 148 15 148 16 148 17 148 21 148 22 148 23 148 24 148 25 148 29 148 35 148 36 149 1 149 4 149 5 149 9 149 12 149 13 149 14 149 15 149 16 149 18 149 20 149 22 149 23 149 25 149 26 149 27 149 28 149 30 149 31 3.36 4.73 0.73 0.54 0.38 0.25 2.50 2.21 2.17 4.59 3.01 1.15 1.05 0.78 2.48 3.46 2.47 0.44 12.18 0.B4 3.48 6.61 0.20

1. B8 0.27 0.68 1.11
1. 40 1.64 1.92 1.B4 1.01 0.29 0.20 4.40 3.98 0.40 0.23 0.52 0.54 0.54 3.72 0.29 2.78 0.95 O.OB 2.B7 5.54 4.87 3.22 5.43 0.44 0.B7 0.37 3.48 7.99 6.90 6.19 0.63 5.99 4.46 1.33 0.74 3.62 0.10 0.49 0.62 0.45 0.31 0.99 0.25 2.09 0.11
11. 53 16.19 27 27 70 63 140 o

21 22 26 32 29 29 199 198 32 28 29 2

2 P 3 P 3 P 3 P 3 2

2 2

2 2

2 1

1 2

2 2

o P 3 1BO 1 30 2

26 2

171 1 B6 P 3 P 1 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 1

35 155 11 21 24 30 30 28 26 15 8

345 31 2

TEA TEA TWO 20 TWO 16 TWO 10 TWO 7 TEA TEA TEA TEA TEA TEA ONT DNT TEA TEA TEA TWO 5 DNT TEA TEA DNT TWO 6 SCI TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO ONT TEA o

60 77 B6 93 100 98 73 39 o

62 P

23 P

109 P 23 2

23 2

30 2

B3 P

27 2

28 2

80 2

33 2

162 1 173 1 178 1 169 1 3 TWD 10 3 TWD 7 3 TWO 13 o

SAl TWO 64 TEA 3 TWD 9 TEA TEA VOL TEA ONT DNT DNT DNT P 3 TWO 5 3 TWD 10 VOL o

P 48 2

175 1 168 1 29 2

163 1 DNT DNT TEA DNT TWO 7 ONT TEA TEA o

P 3 1B3 1 30 2

26 2

o 34 71 o o 128 134 66 108 21 72 P 3 TWO 9 2

TEA 2

VOL P 3 TWD 6 P 3 TWO 7 P 3 TWO 10 P 3 TWO 7 2

TEA P 3 TWO 5 2

TEA 2

VOL 174 1 DNT 178 1 DNT UTE UTE 009 009 009 009 UTE UTE UTE UTE UTE UTE UTS UTS UTE UTE UTE 013 010 UTE UTE 001 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 001 UTE 009 006 009 UTE UTE UTE 012 UTE UTE 008 UTE UTE LTE LTE UTE 011 011 009 LTE LTE UTE UTE 009 LTE UTE UTE 009 UTE 013 012 011 009 008 UTE 011 UTE 014 010 010

-0.15

-0.23

+0.65

-0.68

+0.67

-0.69

-0.23

-0.21

-0.29

-0.14

-0.29

-0.14

+0.71

+1. 66

-0.22

-0.18

-0.24

+0.72

-0.42

-0.29

-0.19

-0.63

-0.62

-0.20

-0.20

-0.20

-0.20

-0.20

-0.20

-0.20

-0.20

-0.20

-0.20

-0.20

-0.79

-0.17

-0.76

-0.58

-0.37

-3.50

-3.50

-0.20

-0.76

-0.19

-0.19

+1.28

-0.23

-11.1B

+11.24

+12.02

-13.30

-0.72

+0.73

+0.77

+11.02

+11. 78

-0.29

-11.25

+0.77

+11.62

-0.17

-0.20

-0.71

-0.20

+0.92

-0.73

-0.53

-0.67

+0.37

-0.11

-0.74

-0.20

-1.02

-0.59

+0.23 TO+297.8 TO+306.7 TO+315.6 TO+324.4 TO+333.3 TO+342.2 TO+351.1 TO+O.O TO+8.9 TO+17.8 05/02/02 13:31:25 Component: S/G B EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE 009 009 009 009 009 009 009 009 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTS UTS UTS UTE UTE UTE UTE UTE UTE 013 013 010 010 UTE UTE UTE UTE 001 001 010 010 UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS 001 001 UTE UTE 009 009 006 006 009 009 UTE lJTS UTE UTS UTE UTE 012 012 UTE UTE UTE UTE 008 008 UTE UTE UTE UTE LTE LTE LTE LTE UTE UTE 011 011 011 011 009 009 LTE LTE LTE LTE UTE UTE UTE UTE 009 009 LTE LTE UTE UTE UTE UTE 009 009 UTE UTE 013 013 012 012 011 011 009 009 008 008 UTE UTE 011 011 UTE UTE 014 014 010 010 010 010 WAR WAR WAR WAR WAR WAR CL/CS WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 2084 2085 4082 4082 4082 4082 2085 2084 2085 2084 2061 2062 4019 4019 2061 2062 2061 4021 4019 2061 2062 4082 4082 2085 2085 2085 2085 2085 2085 2085 2085 2085 2085 2085 4082 2084 4082 4082 4082 2125 2125 2085 4082 2084 2085 4082 2061 4021 4021 4021 4021 4021 4021 4021 4021 4021 2061 4021 4021 4021 2062 2061 4021 2062 4021 4021 4021 4019 4019 2061 4019 2062 4019 4019 4019 INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET Page 154 of 155 PROBE 460HR 460HR 460SI 460S1 460SI 460S1 460HR 460HR 460HR 460HR 460HR 460HR 460S1 460SI 460HR 460HR 460HR 460SI 460S1 460HR 460HR 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460HR 460SI 460S1 460S1 460HR 460HR 460HR 460SI 460HR 460HR 460S1 460HR 460S1 460S1 460SI 460SI 460SI 460SI 460S1 460S1 460S1 460HR 460SI 460SI 460S1 460HR 460HR 460S1 460HR 460S1 460S1 460SI 460S1 460S1 460HR 460S1 460HR 46051 460SI 46051

Framatome ANP Inc.

05/02/02 13:31:27 Customer Name: Oconee Unit 1 Component: S/G B Page 155 of 155 ATTACHMENT #4 - LIST OF IMPERFECTIONS :- MRPC/PLUS POINT QUERY: QueryMI ROW TUBE VOLTS DEG CHN INO %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

==================
===

0.37 125 P 3 TWO 8 009

-0.61 009 009 WAR 4019 INLET 460S1 3.38 29 2

TEA UTE

-0.23 UTE UTE 2062 INLET 460HR 149 33 12.30 170 1 ONT 010

+0.19 010 010 4082 OUTLET 460S1 3.91 29 2

TEA UTE

-0.21 UTE UTE 2061 INLET 460HR 150 3 5.20 180 1 ONT 001

-0.67 001 001 4082 OUTLET 460S1 150 4 3.39 26 2

TEA UTE

-0.21 UTE UTE 2085 INLET 460HR 150 5 3.56 30 2

TEA UTE

-0.18 UTE UTE 2084 INLET 460HR 150 9 2.16 181 1 ONT UTE

-2.59 UTE UTE 4082 OUTLET 460S1 2.82 174 1 ONT UTE

-3.69 UTE UTE 4082 OUTLET 460S1 3.05 359 1 ONT UTE

-6.46 UTE UTE 4082 OUTLET 460S1 4.66 356 1 ONT UTE

-6.87 UTE UTE 4082 OUTLET 460S1

1. 88 26 2

TEA UTE

-0.24 UTE UTE 2085 INLET 460HR 150 11 0.15 65 2

VOL 012

+1.00 012 012 4082 OUTLET 460S1

1. 45 24 2

TEA UTE

-0.27 UTE UTE 2085 INLET 460HR 150 17 6.36 28 2

TEA UTE

-0.24 UTE UTE 2061 INLET 460HR 7.49 183 1 ONT UTS

+12.21 UTE UTS 4032 INLET 460S1 4.86 184 1 ONT UTE

-11.12 UTE UTE 4032 INLET 460SI 0.23 0

P 3 TWO 2 012

+0.73 012 012 WAR 4032 INLET 460SI 0.40 71 P 3 TWO 8 011

-0.76 011 011 WAR 4032 INLET 460SI 3.54 175 1 ONT LTE

+11. 43 LTE LTE 4032 INLET 460SI 6.80 178 1 ONT LTE

+10.46 LTE LTE 4032 INLET 460SI 150 19 2.57 26 2

TEA UTE

-0.22 UTE UTE 2061 INLET 460HR 4.60 176 1 ONT UTE

-12.23 UTE UTE 4021 INLET 460SI 8.13 178 1 ONT UTE

-11. 05 UTE UTE 4021 INLET 460SI 2.72 165 1 ONT LTE

+12.83 LTE LTE 4021 INLET 460SI 6.61 179 1 ONT LTE

+11. 77 LTE LTE 4021 INLET 460SI 150 20 5.70 177 1 ONT UTE

-9.74 UTE UTE 4021 INLET 460SI 0.25 0

P 3 TWO 3 014

+0.70 014 014 WAR 4021 INLET 460SI 0.51 0

P 3 TWO 6 011

-0.53 011 011 WAR 4021 INLET 460SI 0.35 49 2

VOL 007

+2.59 007 007 4021 INLET 460SI 0.42 0

P 3 TWO 6 007

+0.74 007 007 WAR 4021 INLET 460SI 6.13 172 1 ONT LTE

+11. 59 LTE LTE 4021 INLET 460S1 150 22 0.30 32 P 3 TWO 6 010

+0.53 010 010 WAR 4032 INLET 460SI 0.29 145 P 3 TWO 6 010

-0.76 010 010 WAR 4032 INLET 460S1 0.39 122 P 3 TWO 8 009

+0.36 009 009 WAR 4032 INLET 460SI 150 23 3.23 30 2

TEA UTE

-0.21 UTE UTE 2061 INLET 460HR 150 24 2.10 29 2

TEA UTE

-0.26 UTE UTE 2061 INLET 460HR 0.54 139 P 3 TWO 11 010

+0.49 010 010 WAR 4032 INLET 460SI 150 25 2.59 31 2

TEA UTE

-0.20 UTE UTE 2062 INLET 460HR 150 26

1. 94 30 2

TEA UTE

-0.24 UTE UTE 2061 INLET 460HR 150 27 18.60 0

1 ONT 010

+0.20 010 010 4082 OUTLET 460SI 2.40 31 2

TEA UTE

-0.16 UTE UTE 2062 INLET 460HR 151 1 3.32 0

1 ONT 001

-0.72 001 001 4082 OUTLET 460SI 3.68 26 2

TEA UTE

-0.23 UTE UTE 2084 INLET 460HR 151 3

1. 80 170 1 ONT UTE

-6.05 UTE UTE 4082 OUTLET 460SI

1. 85 187 1 ONT UTE

-8.94 UTE UTE 4082 OUTLET 460SI 2.97 20 2

TEA UTE

-0.25 UTE UTE 2085 INLET 460HR 151 6 3.43 30 2

TEA UTE

-0.22 UTE UTE 2084 INLET 460HR 151 8 8.29 169 1 ONT LTE

+11.38 LTE LTE 4082 OUTLET 460SI 0.37 108 P 3 TWO 10 011

+0.16 011 011 WAR 4082 OUTLET 460SI 6.52 169 1 ONT UTE

-11. 36 UTE UTE 4082 OUTLET 460SI 5.40 32 P 1 MCI UTE

-0.29 UTE UTS CS 2085 INLET 460HR 0.75 21 P 3 TWO 0 UTE

-0.29 TO+151.1 UTE UTS 2085 INLET 460HR

1. 82 25 P 3 TWO 52 UTE

-0.29 TO+160.0 UTE UTS 2085 INLET 460HR 3.27 28 P 3 TWO 69 UTE

-0.29 TO+168.9 UTE UTS 2085 INLET 460HR 4.33 31 P 3 TWO 79 UTE

-0.29 TO+177.8 UTE UTS 2085 INLET 460HR 5.20 28 P 3 TWO 87 UTE

-0.29 TO+186.7 UTE UTS 2085 INLET 460HR 4.70 27 P 3 TWO 83 UTE

-0.29 TO+l95.6 UTE UTS 2085 INLET 460HR 3.17 28 P 3 TWO 68 UTE

-0.29 TO+204.4 UTE UTS 2085 INLET 460HR 2.26 25 P 3 TWO 57 UTE

-0.29 TO+213.3 UTE UTS 2085 INLET 460HR 2.09 20 P 3 TWO 55 UTE

-0.29 TO+222.2 UTE UTS 2085 INLET 460HR

1. 34 20 P 3 TWO 44 UTE

-0.29 TO+231.1 UTE UTS 2085 INLET 460HR 0.70 17 P 3 TWO 0 UTE

-0.29 TO+240.0 UTE UTS 2085 INLET 460HR 0.29 11 P 3 TWO 0 UTE

-0.29 TO+337.8 UTE UTS 2085 INLET 460HR 0.85 21 P 3 TWO 48 UTE

-0.29 TO+346.7 UTE UTS 2085 INLET 460HR

1. 34 23 P 3 TWO 60 UTE

-0.29 TO+355.6 UTE UTS 2085 INLET 460HR 2.05 34 P 3 TWO 74 UTE

-0.29 TO+4.4 UTE UTS 2085 INLET 460HR 3.52 32 P 3 TWO 97 UTE

-0.29 TO+13.3 UTE UTS 2085 INLET 460HR 3.20 32 P 3 TWO 93 UTE

-0.29 TO+22.2 UTE UTS 2085 INLET 460HR 2.16 27 P 3 TWO 76 UTE

-0.29 To+31.1 UTE UTS 2085 INLET 460HR 0.51 20 P 3 TWO 37 UTE

-0.29 TO+40.0 UTE UTS 2085 INLET 460HR 0.33 56 P 3 TWO 0 UTE

-0.29 TO+48.9 UTE UTS 2085 INLET 460HR 151 10 4.45 28 2

TEA UTE

-0.31 UTE UTE 2061 INLET 460HR 4.77 185 1 ONT UTE

-12.81 UTE UTE 4032 INLET 460SI 0.30 97 P 3 TWO 6 011

-0.76 011 011 WAR 4032 INLET 460SI

Steam Generator A Page 1 of 3 Attachment #5 - TUBES PLUGGED FOR EDDY CURRENT INDICATIONS ROW TUBE 1

1 5

42 5

8 5

7 5

1 6

2 6

4 6

10 6

32 6

36 7

14 10 60 11 68 11 2

11 1

13 65 15 6

16 80 18 80 18 78 18 77 21 5

22 53 23 3

23 87 25 2

26 93 28 98 30 101 31 73 34 98 39 116 46 74 46 118 48 110 52 118

Steam Generator A Page 2 of 3 Attachment #5 - TUBES PLUGGED FOR EDDY CURRENT INDICATIONS ROW TUBE 54 9

55 125 58 126 58 95 60 77 61 116 62 119 65 21 67 4

71 67 71 1

72 15 73 34 77 106 80 4

80 3

84 3

85 3

86 3

86 76 89 31 89 9

102 16 103 2

107 3

112 47 116 111 125 6

125 4

126 5

130 74 130 6

135 28 136 81 139 67 141 66

Steam Generator A Page 3 of 3 Attachment #5 - TUBES PLUGGED FOR EDDY CURRENT INDICATIONS ROW TUBE 142 6

143 54 150 19

Steam Generator A Page 1 of 2 Attachment #6 - TUBES PLUGGED TO CAPTURE NON-STABILIZED PLUGGED TUBE LOCATIONS ROW TUBE 3

5 3

6 4

8 4

7 5

9 22 92 23 93 24 94 25 96 25 97 25 98 63 130 63 128 65 129 70 129 70 128 70 127 72 127 101 124 103 124 104 123 105 121 105 122 111 116 112 116 126 3

126 2

127 1

127 3

128 2

129 2

129 3

130 3

131 2

131 87 132 1

Steam Generator A Page 2 of 2 Attachment #6 - TUBES PLUGGED TO CAPTURE NON-STABILIZED PLUGGED TUBE LOCATIONS ROW TUBE 133 85 134 84 134 83 137 5

138 3

138 1

139 1

139 2

141 3

141 2

142 2

Steam Generator B Page 1 of 3 Attachment #7 - TUBES PLUGGED FOR EDDY CURRENT INDICATIONS ROW TUBE 1

5 6

48 7

48 12 47 14 71 16 75 17 80 18 79 18 33 19 19 21 29 22 55 24 80 25 40 25 98 26 2

27 88 27 89 36 90 40 6

41 103 41 1

43 8

43 9

43 99 44 25 44 9

47 4

47 116 50 62 52 8

52 9

52 96 53 45 55 63 55 117

Steam Generator B Page 2 of 3 Attachment #7 - TUBES PLUGGED FOR EDDY CURRENT INDICATIONS ROW TUBE 56 123 57 23 57 127 58 117 59 68 59 109 59 123 60 60 60 9

61 15 62 123 62 89 62 3

63 71 63 129 64 126 65 119 66 87 66 4

67 59 67 124 69 122 69 118 70 10 72 123 72 122 72 55 72 4

73 31 73 117 73 118 74 7

74 6

77 86 78 77 78 68

Steam Generator B Page 3 of 3 Attachment #7 - TUBES PLUGGED FOR EDDY CURRENT INDICATIONS ROW TUBE 78 7

79 20 79 116 79 117 79 127 81 74 81 9

82 9

83 126 84 13 85 62 86 4

91 53 93 11 93 69 96 1

97 13 99 69 99 22 103 70 103 95 107 106 108 66 111 74 113 59 119 108 121 74 130 10 135 12 136 72 140 67 141 64 142 13 143 56 149 26

Steam Generator B Page 1 of 5 Attachment #8 - TUBES PLUGGED TO CAPTURE NON-STABILIZED PLUGGED TUBE LOCATIONS ROW TUBE 4

37 4

38 5

42 5

30 5

29 6

31 6

33 6

44 6

46 7

46 8

47 8

50 9

52 12 70 15 77 15 76 16 79 18 81 21 1

22 2

23 2

24 2

24 1

25 11 25 12 26 11 27 11 28 12 30 12 30 14 31 12 47 2

48 2

48 1

51 124 52 125

Steam Generator B Page 2 of 5 Attachment #8 - TUBES PLUGGED TO CAPTURE NON-STABILIZED PLUGGED TUBE LOCATIONS ROW TUBE 53 126 54 126 57 1

58 2

59 2

59 124 60 92 60 91 60 2

61 90 62 128 62 92 76 120 76 121 76 123 77 121 77 118 77 117 77 112 77 111 77 110 77 103 77 102 77 94 77 93 77 80 77 79 77 78 77 49 77 47 77 34 77 33 77 26 77 4

78 8

78 10

Steam Generator B Page 3 of 5 Attachment #8 - TUBES PLUGGED TO CAPTURE NON-STABILIZED PLUGGED TUBE LOCATIONS ROW TUBE 78 15 78 17 78 18 78 25 78 34 78 46 78 49 78 78 78 81 78 93 78 95 78 102 78 104 78 110 78 119 78 122 79 126 79 122 79 121 79 120 79 115 79 114 79 107 79 106 79 98 79 97 79 84 79 83 79 82 79 49 79 48 79 47 79 34 79 33 79 25 79 24

Steam Generator B Page 4 of 5 Attachment #8 - TUBES PLUGGED TO CAPTURE NON-STABILIZED PLUGGED TUBE LOCATIONS ROW TUBE 79 17 79 16 79 10 79 9

79 4

83 131 84 130 85 17 85 129 86 17 87 17 87 18 89 3

90 2

91 3

92 2

93 3

93 1

94 1

95 4

96 3

97 125 97 4

97 3

98 126 100 125 102 121 102 123 103 119 103 118 104 119 105 118 105 117 106 114 106 118 107 119

Steam Generator B Page 5 of 5 Attachment #8 - TUBES PLUGGED TO CAPTURE NON-STABILIZED PLUGGED TUBE LOCATIONS ROW TUBE 108 118 111 4

112 4

112 113 113 113 113 4

114 3

114 5

114 112 115 3

116 3

117 3

119 4

120 3

121 3

122 13 122 2

122 1

123 2

123 3

123 12 124 10 125 10 125 11 125 12 143 4

144 1

144 3

145 1

151 13

Steam Generator A Page 1 of 2 Attachment #9 - TUBES REP AIRED BY REROLLING IN THE HOTLEG ROW TUBE 23 81 24 78 24 13 24 11 27 55 31 20 33 42 33 100 37 73 44 12 47 31 48 116 50 95 51 102 53 69 61 109 62 83 63 59 63 112 64 123 72 67 73 75 77 108 78 66 79 121 80 69 80 64 80 58 81 61 83 69 84 102 86 83 86 67 96 26 104 23 106 30

Steam Generator A Page 2 of 2 Attachment #9 - TUBES REP AIRED BY REROLLING IN THE HOT LEG ROW TUBE 107 92 107 91 109 97 131 11 136 19

Steam Generator B Page 1 of 6 Attachment #10 - TUBES REPAIRED BY REROLLING IN THE HOTLEG ROW TUBE 3

12 6

3 7

26 12 52 14 2

14 27 15 6

15 2

16 56 16 59 18 9

30 56 31 105 31 58 32 90 34 62 34 44 35 53 39 24 40 25 40 78 40 87 41 49 41 46 41 44 41 13 41 8

41 1

42 11 42 22 42 34 43 53 43 36 43 22 43 17 43 13

Steam Generator B Page 2 of 6 Attachment #10 - TUBES REPAIRED BY REROLLING IN THE HOTLEG ROW TUBE 44 32 44 41 44 84 46 82 47 78 48 96 48 73 50 47 50 77 50 89 50 95 51 21 53 11 54 75 54 72 56 56 57 88 57 29 57 23 58 27 59 109 62 81 63 95 63 58 65 23 66 24 67 27 68 65 71 86 71 100 72 37 74 69 74 107 75 95 75 93 76 123

Steam Generator B Page 3 of 6 Attachment #10 - TUBES REPAIRED BY REROLLING IN THE HOTLEG ROW TUBE 77 115 78 74 79 96 80 34 81 65 83 44 83 96 83 126 85 101 85 100 85 96 86 61 87 73 88 48 88 51 88 90 88 94 89 95 89 33 90 18 91 44 93 27 93 33 95 16 96 123 97 116 97 95 97 70 97 56 97 32 97 20 99 78 99 121 100 92 101 25 101 75

Steam Generator B Page 4 of 6 Attachment #10 - TUBES REPAIRED BY REROLLING IN THE HOTLEG ROW TUBE 101 77 101 109 102 105 102 95 102 55 103 36 105 114 105 29 106 85 107 36 108 26 109 16 110 25 110 43 111 28 112 12 112 20 112 56 112 73 113 73 113 67 113 11 114 12 114 69 114 70 114 71 114 84 114 87 114 90 115 39 116 28 116 72 117 15 118 8

118 10 118 24

Steam Generator B Page 50f 6 Attachment #10 - TUBES REPAIRED BY REROLLING IN THE HOTLEG ROW TUBE 118 52 119 63 119 44 119 39 120 36 121 58 121 5

122 6

122 47 122 92 123 88 123 70 123 60 123 48 123 7

124 50 124 79 125 87 125 79 125 43 125 21 125 8

126 2

126 25 126 44 126 46 126 60 126 61 127 87 127 79 127 73 127 68 127 46 127 26 128 22 128 54

Steam Generator B Page 6 of 6 Attachment #10 - TUBES REPAIRED BY REROLLING IN THE HOTLEG ROW TUBE 128 66 128 68 128 70 128 72 128 74 128 77 128 78 128 80 129 77 129 75 129 52 129 46 130 30 130 43 130 47 131 68 131 43 132 50 133 65 133 47 134 12 134 42 141 64 142 28 142 33 145 2