Indiana Michigan Power Company Cook Ndear Pant 500 Crce Drve Bu&ianan, MI 49107 616465-901 INDIANA MICHIGAN POWER July 3, 2002 AEP:NRC:2054-03 10 CFR 50.54(f)
Docket No.:
50-315 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Stop O-P1-17 Washington, DC 20555-0001 Donald C. Cook Nuclear Plant Unit 1 RESPONSE TO NUCLEAR REGULATORY COMMISSION BULLETIN 2002-01 REACTOR PRESSURE VESSEL HEAD DEGRADATION AND REACTOR COOLANT PRESSURE BOUNDARY INTEGRITY
Reference:
- 1. Nuclear Regulatory Commission Bulletin 2002-01, "Reactor Pressure Vessel Head Degradation and Reactor Coolant Pressure Boundary Integrity," dated March 18, 2002
- 2. Letter from J. E. Pollock, Indiana Michigan Power Company, to Nuclear Regulatory Commission Document Control Desk, "Donald C. Cook Nuclear Plant Units 1 and 2, Response To Nuclear Regulatory Commission Bulletin 2002-01, Reactor Pressure Vessel Head Degradation and Reactor Coolant Pressure Boundary Integrity," submittal AEP:NRC:2054-01, dated April 1, 2002
- 3. Letter from J. E. Pollock, Indiana Michigan Power Company, to Nuclear Regulatory Commission Document Control Desk, "Donald C. Cook Nuclear Plant Units 1 and 2, Sixty Day
Response
To Nuclear Regulatory Commission Bulletin 2002-01, Reactor Pressure Vessel Head Degradation and Reactor Coolant Pressure Boundary Integrity," submittal AEP:NRC:2054-02, dated May 17, 2002 In Reference 1, the Nuclear Regulatory Commission requested pressurized-water reactor licensees to provide information related to the integrity of the reactor coolant pressure boundary, including the reactor pressure vessel head, and the extent to which inspections have been undertaken to satisfy applicable regulatory requirements. The bulletin also requested that licensees provide the basis for AEP:
RA merica b" E
- gi,' lPartner 10
U. S. Nuclear Regulatory Commission AEP:NRC:2054-03 Page 2 concluding that their plants satisfy applicable regulatory requirements related to the structural integrity of the reactor coolant pressure boundary, and that future inspections will ensure continued compliance with applicable regulatory requirements. The bulletin required that responses be provided within 15 days of the bulletin, within 30 days after restart following the completion of vessel head examinations, and within 60 days of the date of the bulletin. Indiana Michigan Power Company (I&M) provided information regarding the reactor pressure vessel head in Reference 2. Reference 2 contained information about a Unit 2 examination that was completed during the Unit 2 Cycle 13 refueling outage, and contained a commitment to examine the Unit 1 reactor vessel head during the Unit 1 Cycle 18 refueling outage. Additionally, I&M provided information regarding reactor coolant system integrity for both units in Reference 3.
This letter responds to the request to provide the results of the Unit 1 reactor vessel head inspections within 30 days after restart following the vessel head examination that was performed during the Cycle 18 refueling outage. provides a summary of the results, and Attachment 2 provides a detailed report of the non-destructive examinations that were conducted.
There are no new commitments in this letter. Should you have any questions, please contact Mr. Gordon P. Arent, Manager of Regulatory Affairs, at (616) 697-5553.
Sincerely, J. E. Pollock Site Vice President RV/bjb Attachment c:
K. D. Curry, w/o attachment J. E. Dyer MDEQ - DW & RPD, w/o attachment NRC Resident Inspector R. Whale, w/o attachment
U. S. Nuclear Regulatory Commission AEP:NRC:2054-03 Page 3 AFFIRMATION I, Joseph E. Pollock, being duly sworn, state that I am Site Vice President of Indiana Michigan Power Company (I&M), that I am authorized to sign and file this request with the Nuclear Regulatory Commission on behalf of I&M, and that the statements made and the matters set forth herein pertaining to I&M are true and correct to the best of my knowledge, information, and belief.
Indiana Michigan Power Company J. E. Pollock Site Vice President SWORN TO AND SUBSCRIBED BEFORE ME Commission Expires
/
/
U. S. Nuclear Regulatory Commission AEP:NRC:2054-03 Page 4 bc:
G. P. Arent, w/o attachment A. C. Bakken G. F. Borlodan/C. R. Lane/R. E. Hall P. B. Cowan, w/o attachment E. D. Forbis D. J. Garner S. A. Greenlee S. B. Haggerty D. W. Jenkins, w/o attachment J. A. Kobyra, w/o attachment T. P. Noonan/M. R. Hill J. E. Pollock, w/o attachment T. R. Satyan-Sharma R. J. Sieber J. F. Stang, Jr. - NRC Washington, DC T. R. Stephens T. K. Woods, w/o attachment
ATTACHMENT 1 TO AEP:NRC:2054-03 RESPONSE TO NUCLEAR REGULATORY COMMISSION BULLETIN 2002-01, "REACTOR PRESSURE VESSEL HEAD DEGRADATION AND REACTOR COOLANT PRESSURE BOUNDARY INTEGRITY" Nuclear Regulatory Commission (NRC) Bulletin 2002-01, requested pressurized water reactor licensees to provide information related to the integrity of the reactor coolant pressure boundary, including the reactor pressure vessel head, and the extent to which inspections have been undertaken to satisfy applicable regulatory requirements.
The bulletin also requested that licensees provide the basis for concluding that their plants satisfy applicable regulatory requirements related to the structural integrity of the reactor coolant pressure boundary, and that future inspections will ensure continued compliance with applicable regulatory requirements.
The bulletin required that responses be provided within 15 days of the bulletin, 30 days after restart following the completion of vessel head examinations, and 60 days of the date of the bulletin. This letter addresses the 30-day requirement to provide the results of the reactor vessel head inspection.
NRC Request 2A.
the inspection scope (if different than that provided in response to Item 1.D) and the results, including the location, size, and nature of any degradation detected.
Indiana Michigan Power Company (I&M) Response A letter from J. E. Pollock to NRC Document Control Desk, dated April 1, 2002, provided the 15-day response to the bulletin. As part of the response to item 1.D, I&M committed to perform the following on the Unit 1 reactor vessel head:
A 100% bare metal inspection.
A surface examination (eddy current testing or liquid penetrant) of the wetted surfaces on and near the J-groove weld on the outside and inside diameter, supplemented by ultrasonic testing as necessary for weld locations that are not accessible by eddy current probes, or An ultrasonic test from the inside diameter of the penetration capable of detecting circumferential cracks on the outside diameter above in the vicinity of the J-groove weld.
One Hundred Per Cent Bare Metal Inspection Inspection Methodology The examination was accomplished using a remote crawler that was capable of observing 360 degrees (0) around each vessel head penetration (VHP). In areas where the crawler to AEP:NRC:2054-03 could not gain access, manually operated remote video probes were used, again viewing 360' around each penetration. Qualified ASME Section XI, Level II VT-2 examiners, with additional familiarization about recent industry experience with primary water stress corrosion cracking (PWSCC) were used to perform the actual inspection of the vessel head and each penetration.
Inspection Results No evidence of active or previous leakage from the penetrations or degradation of the vessel head was observed. Indications of small trails of boric acid judged to be from previous venting or leakage from the control rod drive mechanisms' (CRDM) canopy seals were evident on the vessel head penetration (VHP) tubes above the reactor vessel head. There were minor accumulations of boric acid observed on the vessel head. This accumulation coincided with leakage from canopy seals. The area around penetration numbers 4, 12, 28 and 34 required cleaning to examine the bare metal. Vacuuming and wire brushing were used. After cleaning an additional inspection was performed of the area.
Only minor surface rusting was observed.
Some debris was observed and subsequently removed.
In addition to the visual examination for boric acids leakage, an external examination was conducted on penetration 76 based on visual examination results from a 1994 inspection.
During a review of the videotapes from the 1994 inspection, the penetration appeared to have a gouge that could not be fully dispositioned due to interference of the head insulation with the camera angle. A re-examination was conducted after removal of the insulation, and the inspection results showed the indication was a grind mark about 2.74 inches long 1/16 inch wide and 1/64 inches at the deepest part. Based on these results, the indication was considered acceptable for continued use-as-is without any repair.
Nondestructive Examinations Inspection Methodology Seventy-nine VHPs were examined using eddy current (ET), ultrasonic (UT) or liquid penetrant (PT) techniques or a combination of those.
Inspection Results There were no cracks, or crack-like defects observed in any of the seventy-nine penetrations.
Based on the results of a time of flight diffraction UT PCS24 circumferential probe examination, ten penetrations (4, 38, 43, 48, 49, 52, 61, 62, 67, 73) required supplemental examinations. Seven of the penetrations' (4, 38, 43, 48, 52, 61 and
Additional UT probes and techniques were used to examine penetrations 49, 62 and 73.
No evidence of PWSCC was identified.
Page 2 to AEP:NRC:2054-03 Penetration 62 contained 21 separate circumferentially oriented indications on the inside diameter of the tube above and below the J-groove weld. The depth of the indications ranged from less than 1 millimeter (0.039 inch) to 1.5 millimeter (0.059 inch).
The circumferential extent ranged from 260 - 2970. Thirteen of the indications were located above the weld and were less than lmm in depth with a circumferential extent ranging from 260 - 58'. Eight indications were located below the weld with the depth at one spot of 1.5 millimeter (all other indications are 1 millimeter), with a circumferential extent ranging from 1110 - 2970. The indications appeared to have relative uniform spacing between them (see Attachment 2, Page 12). There was no loss of back wall signal or crack tips identified for any of these indications. These indications were dispositioned as being results of the original fabrication process.
A detailed report of the non-destructive examination is provided in Attachment 2.
Overall Conclusions There was no evidence of PWSCC observed. All of the penetrations were determined to be acceptable for continued service.
For those penetrations examined by ET and PT, reasonable assurance exists that primary water did not penetrate the VHP base material or J-groove weld. The UT examinations provide reasonable assurance that circumferential cracking caused by PWSCC at and above the J-groove weld is not present.
NRC Request 2B.
The corrective actions taken and the root cause of any degradation detected.
I&M Response This item is not applicable as no degradation was identified.
Page 3
ATTACHMENT 2 TO AEP:NRC:2054-03 D. C. COOK 1 REACTOR VESSEL HEAD PENETRATION INSPECTION FINAL REPORT
1 D.C. Cook Unit 1
(~)
Westinghouse Reactor Vessel Head Penetration bispection, Pg f1 D.C. Cook 1 Reactor Vessel Head Penetration Inspection Final Report July 1, 2002 Author:
Verifier:
4&L PR.McgrawtV*O.C. Cook Unit I RVHP Inspection Final Report PRELIMINARY.doC
D.C. Cook Unit I Westilghouse Reactor Vessel Head Penetration nspection P
D.C. Cook 1 Reactor Vessel Head Penetration Inspection Final Report 1.0 DISCUSSION During the D.C. Cook Unit 1 May 2002 outage, Westinghouse performed nondestructive examinations of all 79-reactor vessel head penetrations (RVHP). The inspections were performed in accordance with the following field service nondestructive examination procedures:
ISI-UT-002, Rev. 1 - "Time of Flight Ultrasonic Inspection of Reactor Vessel Head Penetrations' ISI-UT-003, Rev. 0 - "Ultrasonic Inspection of Reactor Vessel Head Penetrations Using Pulse Echo Techniques" ISI-ET-00 1, Rev. 2 - "Eddy Current Inspection of J-Groove Welds in Vessel Head Penetrations" ISI-ET-002, Rev. 2 - "Eddy Current Procedure for Detection of Cracks in Vessel Head Penetrations With or Without Thermal Sleeves - Differential Gap Probe" WDI-UT-008, Rev. 0 - "Intraspect Time of Flight Ultrasonic Inspection of Reactor Vessel Head Penetrations" WDI-UT-009, Rev. 0 - "IntraSpect Ultrasonic Procedure for Detection of Circumferential Indications in Reactor Vessel Head Penetration Welds - 0 Degree to 20 Degree Probes" WDI-ET-003, Rev. 0- "IntraSpect Eddy Current Imaging Procedure for Inspection of Reactor Vessel Head Penetrations" The vessel head penetrations were dispositioned based on an assessment of 1) results from the ultrasonic and eddy current examinations presented herein, 2) results from visual examinations of 100% of the penetrations from the top of the head, and 3) results from supplementary liquid penetrant examinations.
2.0 SCOPE OF WORK The RVBP examination scope at D.C. Cook Unit 1 was based on a commitment to perform:
- 1) An under the insulation bare-metal exam, and
- 2) Surface examinations of the penetration wetted surfaces, or P:'MgrawLV1D.C. Cook Unit 1 RVHP krspection Final Report PRELIMINARYA.C
g RD.C.
Cook Unit 1
- 3) Volumetric examinations to identify the presence of circumferentially oriented primary water stress corrosion cracking (PWSCC) on the OD surfaces of the penetrations above the J-Groove welds attaching the penetrations to the reactor vessel head.
The delivery system used for the vessel head penetration inspections at D.C. Cook Unit 1 was the Westinghouse DERI 700 manipulator. The DERI 700 is a multi-purpose robot that can access all head penetrations without repositioning and provides a common platform for all reactor vessel head penetration inspection end effectors. The manipulator consists of a central leg, mounted on a carriage, which in turn is mounted onto a guide rail. The manipulator arm, with elbow and removable wrist, is mounted onto the carriage, which travels vertically along the manipulator leg. The DERI 700 was used to deliver the 7010 open housing scanner for eddy current and ultrasonic examinations of six thermocouple column locations and the ultrasonic gap scanner for ultrasonic time-of-flight examinations of fifty-seven penetrations. The eddy current gap scanner and Grooveman end effector were used for eddy current examinations of the inside diameter surfaces, J-Groove welds and outside diameter surfaces of sixteen penetrations.
The 7010 open housing scanner delivers a probe assembly containing ultrasonic and eddy current probes to the ID surface of open reactor vessel head penetrations. The scanning motion is in the axial direction and the probe is indexed in the circumferential direction.
The eddy current and ultrasonic gap scanners are designed to position and guide "sword" probes into the annulus between the ID surface of the reactor vessel head penetration tube and the OD surface of the thermal sleeve and to manipulate the probe to provide the desired coverage. The nominal annulus size is 0.125". The sword probe design utilizes a flexible metal "sword" on which a pair of eddy current or ultrasonic probes are mounted in a spring configuration that enables the probes to ride on the ID surface of the penetration tubes. The scanning motion is in a vertical direction moving from a specified height above the weld toward the lower end of the penetration and the probes are indexed in the circumferential direction. The gap scanners consist of a probe tilt and drive unit to advance and reverse the probe in the tube/thermal sleeve annulus, a turntable to rotate the probe drive around the axis of the penetration, a lifting cylinder to raise and lower the tilt and drive unit and a centering device consisting of two clamping arms. The ultrasonic gapscanner also has a couplant delivery system.
The Grooveman end effector is designed deliver eddy current probes for examination of the surface of the J-Groove weld and the penetration nozzle OD surface. The eddy current probe holders are designed to conform to the geometry of the J-Groove welds and penetration OD surfaces which allow the probes to follow the contour of the assembly. Continuous positional and video feedback is provided to the operator to assist in examining the full surface of the weld and the penetration tube. Scanning of the penetration OD surfaces is conducted in a vertical direction and the probes are indexed in the circumferential direction. For scanning of the J-Groove welds, scanning is conducted in the circumferential direction, along the welds, and the index is in a direction perpendicular to the welds.
P:VihcgrawLV\\D.C. Cook Unit I RVHP Inkspecton Final Report PRIELIMINARY.doc
SW~ingons
- page 4.of 12
-ReactorVessel Head Penetration Inspection 2.1 Time-of-Flight Ultrasonic Examinations with the UT Gapscanner Fifty-seven penetrations were examined using time-of-flight diffraction ultrasonic techniques with PCS24 probes demonstrated capable of detecting circumferentially oriented reflectors on the tube OD surfaces above the elevation of the J-Groove weld. These examinations were conducted with PCS24 probes directed along the tube axis in accordance with ISI-UT-002, Rev. 1; 'Time of Flight Ultrasonic Inspection of Reactor Vessel Head Penetrations". These examinations were conducted with PCS24 TOMD 6.0 MHz ultrasonic transducers.
2.2 Eddy Current Inspection of Penetration II) Surfaces with the ECT Gapscanner The inside diameter surfaces of sixteen penetrations were inspected with eddy current techniques in accordance with ISI-ET-002, Rev. 2; "Eddy Current Procedure for Detection of Cracks in Vessel Head Penetrations With or Without Thermal Sleeves - Differential Gap Probe". These penetration locations were identified for eddy current inspection because they could not be completely examined with the time-of-flight diffraction ultrasonic technique. Centering buttons on the penetration thermal sleeves at thirteen of these locations were at elevations that would not permit the ultrasonic probe to reach the desired height above the weld. At three locations difficulty was encountered with the ability of the TOMD probe to access the penetration through the gap created by the thermal sleeve and the penetration tube ID.
These inspections were performed using a pair of differentially connected pancake coils positioned at 45 degrees to one and other. The inspection frequencies were 600, 280 and 100 kHz in both the absolute and differential modes. The prime frequency was 600 kHz in the differential mode.
2.3 Eddy Current Inspection of J-Groove Welds and Penetration OD Surfaces The J-Groove welds and OD surfaces at sixteen penetration locations were inspected with eddy current techniques in accordance with ISI-ET-001, Rev. 2; "Eddy Current Inspection of J-Groove Welds in Vessel Head Penetrations". These penetration locations were identified for eddy current inspection because they could not be completely examined with the time-of-flight diffraction ultrasonic technique.
Centering buttons on the penetration thermal sleeves at thirteen of these locations were at elevations that would not permit the ultrasonic probe to reach the desired height above the weld. At three locations difficulty was encountered with the ability of the TOFD probe to access the penetration through the gap created by the thermal sleeve and the penetration tube ID.
These inspections were performed using a 3mm diameter, x-wound coil in a driver-pickup configuration.
The inspection frequencies were 400 and 450 kHz.
Penetrations #73 and 70 could not be inspected over their entire length, due to the acute angle between the vessel head and the penetration tube J-weld. These locations were subject to supplementary liquid penetrant examinations.
P:\\McgrawLV\\D.C. Cook Unit 1 RVHP Inspection Final Report PRELIMINARY.doc
S]
- D.C. Cook UnitI
. ReactorVessel Head Penetration Inspection
( ) WestinghouseReato D
.C.Cok ni PageSor 12 2.4 Rotating Probe Examinations Rotating probe examinations were conducted on the six-thermocouple column locations. These examinations included:
- 1) TOFD ultrasonic techniques demonstrated capable of detecting axial and circumferential reflectors on the tube OD surfaces with 5.0 MHz PCS24 probes in accordance with WDI-UT-008, Rev. 0; "Intraspect Time of Flight Ultrasonic Inspection of Reactor Vessel Head Penetrations",
- 2) eddy current examinations using crosswound coils operated at 400 kHz demonstrated capable of detecting axial and circumferential degradation on the tube ID surface in accordance with WDI-ET 003, Rev. 0; "IntraSpect Eddy Current Imaging Procedure for Inspection of Reactor Vessel Head Penetrations", and
- 3) 00, 2.25 MHz and 5.0 MHz longitudinal wave examinations of the J-Groove welds in accordance with WDI-UT-009, Rev. 0; "IntraSpect Ultrasonic Procedure for Detection of Circumferential Indications in Reactor Vessel Head Penetration Welds - 0 Degree to 20 Degree Probes".
2.5 Summary of All RVHP NDE Inspections at D.C. Cook Unit 1 The following table provides a summary of all RVHP nondestructive inspections performed at D.C.
Cook Unit I during the May 2002 refueling outage.
Penetration ECT of JwGroove ECT of TOFD UT Rotating Qualified Liquid Weld and Penetration Penetration ID PCS24 Ax.
Probe Visual Penetrant OD Surfaces Surfaces (VT-2)
(PT) 1 x
x 2
x 3
x 4
Supplemental x
5 x
6 x
x 7
x x
8 x
x 9
x x
10 x
x x
11 x
x x
12 x
x x
13 x
x x
14 x
x x
15 x
x 16 X
x x
17 x
x 18 xx x
P:\\cgrawLVYD.C. Cook Unit I RVHP Inspecdon Final Report PRELIMVINAY.doc
SD.C.
Cook Unit 1 Page of 12 W tn osReactor Vesel Head Penetration spection Pane 6 o Penetration ECT of J-Groove ECT of TOFM UT Rotating Qualified Liquid Weld and Penetration Penetration ID PCS24 Ax.
Probe Visual Penetrant OD Surfaces Surfaces (VT-2)
(PT) 19 x
x 20 x
x x
21 x
x 22 x
x 23 x
x 24 x
x 25 x
x 26 x
x 27 x
x 28 x
x 29 x
x 30 x
x 31 x
x 32 x
x 33 x
x 34 x
x 35 x
x 36 x
x 37 x
x 38 Supplemental x
x 39 x
x 40 x
x 41 x
x 42 x
x 43 Supplemental x
x 4x x
45 x
x 46 x
x 47
__x x
48 Supplemental x
x 49 x
x 50 x
x 51 x
x 52 Supplemental x
x 53 x
x 54 x
x 55 x
x 56 x
x 57 x
x 58 x
x 59 x
x 60 x
x 61 Supplemental x
x P:V,,cgrawLV'D.C. Cock Unit I RVHP Inspection F'W Report PREUMINARY.doc
S*....
D.C Cook Unit 1 7o Reactor Vessel Head Penetrationtinsipection, Penetration ECT of J-Groove ECT of TOFD UT Rotating Qualified Liquid Weld and Penetration Penetration ID PCS24 Ax.
Probe Visual Penetrant OD Surfaces Surfaces (VT-2)
(PT) 62 x
x 63 x
x 64 x
x 65 x
x 66 x
x 67 Supplemental X
x 68 x
X 69 x
x X
70 x
x x
x 71 x
x 72 x
x 73 Xx x
x 74 x
x 75 x
x 76 x
x 77 x
x 78 x
x 79 x
x 3.0 EDDY CURRENT AND ULTRASONIC INSPECTION RESULTS 3.1 Time-of-Flight Ultrasonic Examinations with the UT Gapscanner Fifty-seven penetrations were examined using time-of-flight diffraction ultrasonic techniques with PCS24 probes.
Ten of those penetrations were identified for additional investigation. Investigations were conducted on seven of those locations; #4, 38, 43,48, 52, 61, and 67, using eddy current techniques in accordance with ISI-ET-001, Rev. 2; "Eddy Current Inspection of J-Groove Welds in Vessel Head Penetrations".
Penetrations #62 and 73 were investigated with 45 degree techniques in accordance with ISI-UT-003, Rev. 0 - "Ultrasonic Inspection of Reactor Vessel Head Penetrations Using Pulse Echo Techniques" and penetrations #49 and 62 were investigated with PCS 10 TOMD circ probes in accordance with ISI-UT 002, Rev. 1; '*Time of Flight Ultrasonic Inspection of Reactor Vessel Head Penetrations".
PAMcgrawLVCD.C. Cook Unit I RVHP Irspection FiMat Report PRELIMINARY.doc
) Wet s
Reactor D.C. Cook Unit 1 RatrVessel Read Penetrationiins age 8of 1 3.2 Eddy Current Inspection of Penetration ID Surfaces with the ECT Gapscanner Eddy current examinations of sixteen penetration tube ID surfaces were conducted with the eddy current gapscanner. No detectable degradation (NDD) was identified in any of the penetrations. Inspection coverage and a summary of results are found in the following table.
Penetration Inspection Number Results 1
NDD 6
NDD 7
NDD 8
NDD 9
NDD.
10 NDD "11 NDD 12 NDD 13 NDD 14 NDD 16 NDD 18 NDD 20 NDD "69 NDD 70 NDD 73 NDD 3.3 Eddy Current Inspection of J-Groove Welds and Penetration OD Surfaces Eddy current inspections of sixteen J-Groove welds and penetration tube OD surfaces were conducted to the extent possible. All weld surfaces were prepared by grinding to a smooth finish.
For this examination, penetrations were classified as containing no reportable indications (NRI),
recordable indications, or reportable indications. Criteria for these classifications are found in the Analysis Logic Chart in ISI-ET-001, Rev.2, "Eddy Current Inspection of J-Groove Welds in Vessel Head Penetrations". Reportable indications are those exhibiting phase angles of 900 + 150 (circumferential) or 2700 + 150 (axial), signal-to-noise ratios greater than 2:1, and lengths 9 mm or greater.
Penetration Number Inspection Results Inspection Results Penetration OD J-Groove Weld Surface 1
NRI NRI 6
NRI NRI 7
Nl, NRM 8
NRI NRI 9
NRI NRI 10 NRI NRI 11 Nm NRI 12 NRI NRI P:VgcrwLVD.C. Cook Unit 1 RVHP Inspection Final Report PIIEUMINARY.doc
eD.C.
Cook Unit 1 SReactorVesselI Head Penetration Inspection Penetration Number Inspection Results Inspection Results Penetration OD J-Groove Weld
________ _ Surface 13 NRI NRI 14 NRI NRI 16 NRI NRI 18 NRI NRI 20 NRI NRI 69 NRI "NR 70*
NMI NRJ 73*
NRI NRI Coverage limited to 700 to 2850, supplementary penetrant testing performed There were no reportable or recordable indications identified in any of the J-Groove weld or penetration OD surface inspections. Penetrations #70 and #73 were also inspected with liquid penetrant techniques in areas not accessible with the J-Groove eddy current inspection tooling.
3.4 Rotating Probe Examinations A summary of results from the rotating probe examinations of six thermocouple column locations is provided in the following table:
Penetrat PCS24 PCS24 0 Degree 20 Degree Eddy ion Axial Circumferent Longitudinal Longitudinal Current Number lal 2.25 MHz 5.0 MHz 74 NDD NDD NDD NDD NDD 75 NDD NDD NDD NDD NDD 76 NDD NDD NDD NDD NDD 77
,NDD NDD NDD NDD NDD 78 NDD NDD NDD NDD NDD 79 NDD NDD NDD NDD NDD 4.0 DISCUSSION OF RESULTS A total of 10 penetrations were identified for further investigation based on results from the PCS24 sword probe examinations.
Investigations were conducted on seven of those locations; #4, 38, 43, 48, 52, 61, and 67, using eddy current techniques in accordance with ISI-ET-001, Rev. 2; "Eddy Current Inspection of J-Groove Welds in Vessel Head Penetrations". Penetrations #62 and 73 were investigated with 45 degree techniques in accordance with ISI-UT-003, Rev. 0- "Ultrasonic Inspection of Reactor Vessel Head Penetrations Using Pulse Echo Techniques" and penetrations #49 and 62 were investigated with PCS 10 TOFD circ probes in accordance with ISI-UT-002, Rev. 1; "'Time of Flight Ultrasonic Inspection of Reactor Vessel Head Penetrations".
P:AMcgrawLV\\D.C. Cook Urit 1 RVHP Inspecdon Final Rep0ol PREUMINARY.ACC
(~)
Wesinhoue eacor D.C. Co ok Unit 1 SWestinpfouo
."page
- 10. of 1i2 RatrVessel Head Penetration Inspecton Pae1of2 Results of these supplementary examinations indicate no evidence of primary water stress corrosion cracking in any of the 79 reactor vessel head penetrations. One penetration, #62, has indications on the penetration tube inside diameter surface that appear to be associated with the manufacturing process. These indications are circumferential in orientation and most have depths less than 1.0 num.
The characteristics of the indications are listed in the following table and shown in the attached graphic. The indications do not appear to be crack-like, but likely a result of the manufactuing process.
P:RlcrawLVmD.C. Cook Unit 1 RVHP Inspection Final Repout PRELIMINARY.OC2
D.C. Cook Unit 1
(~~)
WesinghouseReactor essel. Head Penetration lnspectin Pae.
r1 Penetration #62 - Indication Characteristics Notes:
- 1. Altitudes are from bottom of penetration.
- 2. Each indication below the weld is at a constant elevation.
PAMcgrawLV\\D.C. Cook Unit 1 RVHP Inspection Final Report PREUMINARY.doc Indication Top Side Top Bottom Side Bottom Angular Length No.
azimuth Altitude azimuth Altitude Depth Span (approx.)
(deg.)
(mm)
(deg.)
(mm)
(mm)
(deg.)
(mm)
Above Weld 1
133 236 82 235
<<I 51 31 2
137 218 79 226
<<1 58 35 3
138 219 81 217
<<I 57 35 4
138 209 85 207
<<1 53 32 5
138 202 83 200
<<I 55 34 6
128 192 93 190
<<1 35 21 7
138 186 93 185
<<I 45 27 8
138 177 104 175
<<I 34 21 9
158 171 106 165 c<<1 52 32 10 150 160 110 156
<<1 40 24 11 145 153 119 150
<<I 26 16 12 149 144 119 141
<<I 30 18 13 147 128 119 128
<<1 28 17 Below Weld 14 159 77 48 same 1
111 68 15 178 71 44 same 1
134 82 16 164 65 14 same 1
150 91 17 191 61
-7 same 1
198 121 18 174 58
-17 same 1
191 116 19 180 55
-19 same 1
199 121 20 193 51
-11 same 1
204 124 21 274 41
-23 same 1.5 297 181
,CN D.C. Cook Unit 1 Westinghouse Reactor Vessel Head Penetration Inspection Below Weld Indications 21 to 14 Penetration #62 PCS 10 Circ Results Above Weld Indications 13 to I col C %DOCUME-1~S91 876,MOCAtS-1*Týnp%-1tO4789.doc