Steam Generator In-Service Inspection Summary Report Unit 2, End of Cycle (EOC) 14
ML021640320
Person / Time
Site: Mcguire
Issue date: 05/30/2002
From: Barron H
Duke Energy Corp
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML021640320 (22)


Text

P Duke fEnergy.

Duke Energy Corporation McGuire Nuclear Station 12700 Hagers Ferry Road Huntersville, NC 28078-9340 (704) 875-4800 OFFICE (704) 875-4809 FAX H. B. Barron Vice President May 30, 2002 U. S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555-0001

Subject:

McGuire Nuclear Station Docket Nos. 50-370 Steam Generator In-Service Inspection Summary Report Unit 2, End of Cycle (EOC) 14 Please find attached the Steam Generator In-Service Inspection (ISI) Outage Summary Report for the McGuire Unit 2, EOC 14 refueling outage. This report in submitted pursuant to the filing requirements of ASME Section XI Code 1989 Edition, paragraph IWA-6230.

Questions regarding this submittal should be directed to Kay Crane, McGuire Regulatory Compliance (704) 875-4306.

H. B. Barron Attachment P47

U. S. Nuclear Regulatory Commission Document Control Desk May 30, 2002 Page 2 cc:

L. A. Reyes U. S. Nuclear Regulatory Commission Regional Administrator, Region II Atlanta Federal Center 61 Forsyth St. Suite 23T85 Atlanta, GA 30303 R. E. Martin NRC Senior Project Manager (MNS)

U. S. Nuclear Regulatory Commissior.

Mail Stop 0-8 H12 Washington, DC 20555-0001 S. M. Shaeffer Senior Resident Inspector (MNS)

U. S. Nuclear Regulatory Commission

U. S. Nuclear Regulatory Commission Document Control Desk May 30, 2002 Page 3 bxc:

G.W. Crump EC050-ELL Master File RGC File

Steam Generator Outage Summary Report McGuire Unit 2 2002 Outage EOC 14 Location: Hwy. 73, Cowans Ford, North Carolina 28216 NRC Docket No. 50-370 National Board No. 84 Commercial Service Date: March 1, 1984 Owner: Duke Energy Corporation 526 South Church St.

Charlotte, N.C. 28201-1006 Revision 0 Prepared By:

Reviewed By:

Approved By:

//

Date:

-/1,40 Z Date:

". (,02.

Date: 5 4 -

Copy No.

Controlled:

1 1 -

Assigned To:

Uncontrolled:

Aec &Votoa a4?"o /

Controlled Distribution Copy No.

Assigned To Original McGuire Nuclear Station Document Control Master File MC 1201.35 1

NRC Document Control Uncontrolled Distribution 2

Hartford Steam Boiler Inspection and Insurance Company of Connecticut (AIA) 3 State of North Carolina Department of Labor C/o J. M. Givens, Jr.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Duke Power Company, 526 S. Church St.. Charlotte, NC 28201-1006 (Name and Address of Owner)

2.

Plant:

McGuire Nuclear Station, 12700 Hagers Ferry Rd., Huntersville, NC 28078

3.
5.

7.

(Name and Address of Plant)

Plant Unit:

2

4.

Owner Certificate of Authorization (if required)

N/A Commercial Service Date March 1, 1984

6. National Board Number for Unit 84 Components Inspected:

Component or Appurtenance 2B Steam Generator 2C Steam Generator Manufacturer or Installer B&W Canada B&W Canada Manufacturer or Installer Serial No.

7700-04 7700-01 State or Province No.

N/A N/A Note:Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) information in items 1 through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

National Board No.

161 158

FORM NIS-1 (Back)

8.

Examination Dates March 4, 2002 to March 13, 2002

9.

Inspection Period Identification:

PPriod of the 2nd Interval

10.

Inspection Interval Identification:

2nd Interval

11.

Applicable Edition of Section XI 1989

12.

Date/Revision of Inspection Plan:

3/14/2002 Rev. I

13. Abstract of Examinations and Test.

Addenda None Refer to Attached Steam Generator Outage Summary Report

14. Abstract of Results of Examination and Tests.

Refer to Attached Steam Generator Outage Summary Report

15. Abstract of Corrective Measures.

Refer to Attached Steam Generator Outage Summary Report We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicabl Date Z

20 02_ Signed e)

N/A Expiration Date N/A Duke Power Co.

By Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of North Carolina employed by

  • HSB CT have inspected the components described in this Owners' Report during the period -,

K.

a 0 0 to J04as avola

, and state that to the best of my knowledge and belief, the Owner has performed examinatioudand tests and taken corrective measures described in the Owners' Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, test, and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions I insp'6-tr's Signature Date 4

4 0 -dL a National Board, State, Province, and Endorsements J

  • The Hartford Steam Boiler Inspection & Insurance Company of Connecticut 200 Ashford Center North Suite 300 Atlanta, GA. 30338 Kd /-g, tiJ (LM_

.1 1

DE&S Duke Engineering & Services Outage Summary Report for McGuire Nuclear Station Unit 2 EOC 14 Project Manager

  • r R79 Date 5-o?

1.0 Introduction The Inconel 690 tubing in the two Babcock and Wilcox Canada (BWC) CFR 80 series recirculating steam generators (RSG's) B and C, at Duke Power Company's McGuire Unit 2 were examined with eddy current techniques in March 2002. The tubing in the steam generators measures 0.688" nominal O.D. X 0.040" nominal wall thickness. The eddy current examination was performed by DE&S and Framatome ANP personnel during the MNS 2-EOC-14 inservice inspection.

This report documents the bobbin coil and MRPC examination results.

2.0 Summary The following is a summary of indications and/or tubes examined with eddy current for each steam generator.

Note: All bobbin examinations were performed with a Zetec or R/D Tech "tuned" probe in both steam generators.

2.1 RSGB Bobbin

  • 6630 tubes were examined full length 0 634 tubes (rows 1-9) were examined straight length from the cold leg 634 tubes (rows 1-9) were examined over the u-bend length from the hot leg MRPC 1 outlet special interest location 27 u-bend special interest locations 3 inlet special interest location 0

No mechanical plug inspection I

2.3 RSG C Bobbin a

6632 tubes were examined full length

  • 634 tubes (rows 1-9) were examined straight length from the cold leg
  • 634 tubes (rows 1-9) were examined over the u-bend length from the hot leg MRPC 20 outlet special interest locations 49 u-bend special interest locations 11 inlet special interest location No mechanical plug inspection 3.0 Examination The examinations, equipment, and personnel were in compliance with the requirements of the DE&S NDE Procedure Manual for Inservice Inspection, the applicable Duke Power Technical Specifications, the ASME Boiler and Pressure Vessel Code Section XI, 1989 Edition, and industry standards. Analysis of the eddy current data was performed in accordance with "Eddy Current Analysis Guidelines for McGuire Unit 2 EOC 14".

The steam generator tubing examinations were performed by technicians qualified to Level II or higher, Level I personnel were under the direct supervision of a qualified Level II or higher. Personnel qualified to a minimum of Level IIA evaluated the data.

The examination and evaluation techniques were approved by personnel qualified to Level I1.

The bobbin coil examinations were performed with.560 inch diameter probes at frequencies of 650, 320, 170 and 35 kHz operating in differential and absolute modes.

The frequencies were generated with a Zetec MIZ-30 Remote Data Acquisition Unit.

A 650/170 kHz differential tube support plate (TSP) suppression mix was used to enhance the detection of indications at TSP intersections.

In addition, a 320/170 kHz absolute mix was used to detect wear indications at support plates and fan bars.

A 650/320/170/35 differential turbo mix was also used to enhance the detection of indications at tubesheet transitions and NQI indications.

Additional process channels were used for automated analysis to enhance detection.

2

The MRPC examination was used as a supplemental examination to detect and characterize indications reported by bobbin.

The MRPC examination was performed with.540 or.520 inch diameter probes at frequencies of 400, 300, 200, 100 and 15 kHz. A 300/100 kHz absolute mix was used to improve the detection of indications at TSP locations.

Official results of the data analysis were recorded on optical disks and then loaded into the "Eddy current Inspection Management System" (EIMS) and the "Framatome Data Management System" (FDMS) data management systems. These systems were used to check the data for invalid analysis entries, perform data sorting routines, ensure that the required extents of all tubes in the inspection plan were examined, and to print out final data sheets.

Note:

A list of all three-digit codes and acronyms used throughout this report can be found in "Attachment 3A" of the Bobbin Analysis Guidelines and "Attachment 1B" of the Rotating Coil Analysis Guidelines.

4.0 Results The McGuire Unit 2 CFR 80 series steam generators have minimal manufacturing discontinuities with the eddy current results verifying a number of manufacturing burnish marks (MBM).

The "Absolute Drift Indications" (ADI) code was used for reporting absolute signals for indications where an adequate differential response was not present and the absolute signal was indicative of degradation.

The "Non-Quantifiable Indications" (NQI) code was used for reporting signals of interests where two differential channels did not correlate within 10% or an accurate percent throughwall could not be assigned.

3

The following are results from the Bobbin and MRPC examinations:

4.1 RSG B:

4.1.1 Bobbin Coil Examination 3 tubes with 4 ADI indications 0 tubes with 0 DNT indications 0 tubes with 0 NQI indications 26 tubes with 27 Fan Bar Wear indications 2 tubes with 2 PLP indications 4.1.2 All MRPC Examinations 1 tube with 1 Volumetric indication No I code indications 24 tubes with 24 Fan Bar Wear indications (Confirmed with Pancake) 2 tubes with 2 PLP indications (confirmed with MRPC)

No tubes required repair 4.2 RSG C:

4.2.1 Bobbin Coil Examination 6 tubes with 7 ADI indications 1 tube with 1 DNT indication 0 tubes with 0 NQI indications 22 tubes with 22 PLP indications 55 tubes with 55 Fan Bar Wear indications 4.2.2 MRPC Examination 0 tubes with 0 Volumetric indications No I code indications 55 tubes with 44 Fan Bar Wear indications (Confirmed with Pancake) 22 tubes with 2 PLP indications (confirmed with MRPC)

No tubes required repair 5.0 Documentation All optical disks (working copies) and row/column examination results will be retained by DE&S.

4

March 18, 2002 Michael T. Cash Regulatory Compliance -MG02RC Attention:

Kay Crane

Subject:

McGuire Nuclear Station Unit 2 Steam Generator NRC Inspection Report - 15 Day & 12 Month

Dear Sir,

Pursuant to Technical Specification 5.6.8 part b., the following information is submitted:

1.

The following quantity of tubes were inspected from either side of the Generator.

Steam Generator B

B C

C Quantity 6630 29 6632 79 I nspection Method Bobbin MRPC Bobbin MRPC

2.

The following information is submitted concerning tube indications of imperfections. (The attached list identifies the tubes with imperfections, their locations and their size.)

Steam Generator B

C

3.

There were no tubes removed from service by plugging.

Attachment 1

2

For further information, please contact me at 704-875-5563.

Sincerely, 4wlw" Emma N. Currence Eddy Current Data Administrator cc:

w/o Attachments w/Attachments W.F. Brady

- EC090 R.W. Eaker

- EC07E W.M. Sample - EC07E W.K. Davis

-.EC07E G.W. Crump - EC07E D.E. Kinard

- MGO1MM

Framatome ANP Inc.

03/18/02 13:43:39 Component: S/G B Indications of Imperfection ROW COL VOLTS 2

123 0.65 9

130 0.20 12 85 0.30 25 24 0.35 47 80 0.27 49 70 0.35 49 82 0.71 54 73 0.14 54 83 0.15 58 71 0.37 0.58 62 61 1.58 62 93 0.23 0.15 64 77 0.18 66 83 0.19 68 71 0.33 70 67 0.18 0.26 72 53 0.37 72 89 0.13 0.10 73 66 0.14 0.24 75 108 0.22 76 77 0.53 77 66 0.12 0.28 78 61 0.18 0.17 78 77 0.17 79 66 0.15 80 67 0.23 0.23 81 78 0.21 84 67 0.24 0.15 85 64 0.32 0.17 87 66 0.14 0.19 87 78 0.20 89 72 0.27 90 67 0.32 0.41 0.08 0.60 91 60 0.24 0.18 91 66 0.15 0.18 91 68 0.16 0.12 93 114 1.14 0.22 0.11 95 114 1.39 0.21 0.10 98 75 0.14 0.09 99 74 0.28 0.16 99 80 1.17 100 95 0.47 101 66 0.15 0.17 102 61 0.30 0.47 103 76 0.13 0.15 104 49 0.25 105 66 0.27 0.33 DEG CHN IND %TW 42 6

HNI 83 6

HNI 78 6

ADI 76 6

HNI 88 6

HNI 84 6

HNI 18 P 1 HNI 86 6

HNI 93 6

HNI 91 6

ADI 96 6

ADI 16 1

HNI 92 P 2 TWD 6 18 P 3 TWD 5 81 6

ADI 84 6

HNI 131 P 1 HNI 0

P 2 TWD 5 0

P 3 TWD 8 86 6

HNI 77 P 2 TWD 4 0

P 3 TWD 3 0

P 2 TWD 4 0

P 3 TWD 7 66 6

HNI 97 6

HNI 0

P 2 TWD 3 0

P 3 TWD 8 0

P 2 TWD 5 0

P 3 TWD 5 99 P 2 TWD 5 0

P 2 TWD 4 0

P 3 TWD 8 0

P 2 TWD 6

87 P 2 TWD 6 0

P 3 TWD 9 0

P 2 TWD 4 108 P 3 TWD 7 0

P 2 TWD 5 0

P 3 TWD 5 0

P 2 TWD 5 85 6

HNI 74 6

HNI 0

P 3 TWD 11 0

P 2 TWD 11 0

P 2 TWD 2 84 P 2 VOL 0

P 3 TWD 9 0

P 2 TWD 5 0

P 3 TWD 5 0

P 2 TWD 5 0

P 3 TWD 6 0

P 2 TWD 3 164 5 PLP 87 10 PLP 91 10 PLP 160 5 PLP 68 10 PLP 94 10 PLP 76 P 2 TWD 4 10 P 3 TWD 2 53 P 2 TWD 8 0

P 3 TWD 6 72 6-HNI 71 6

HNI 0

P3TWD6 0

P 2 TWD 4 0

P 3 TWD 11 0

P 2 TWD 12 115 P 2 TWD 4 0

P 3 TWD 6 91 6

HNI 0

P 2 TWD 7 0

P 3 TWD 10 LOCATI 08H 03H 08C 06C 04H 01H 09C 05H 04H 02H 06H 09C FB5 FB5 05H 05H CBH FB5 FB5 01H FB8 FB8 FB4 FB4 04H 02C FB4 FB4 FB5 FB5 FB2 FB4 FB3 FB3 FB5 FB4 FB4 FB7 FB7 FB3 FB3 01C 09C FB4 FB4 FB5 FB5 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB6 FB6 FB4 FB4 08C TSH FB3 FB3 FB4 FB4 FB3 FB3 04H FB3 FB3 ON

+30.70

+18.51

+36.49

+34.56

+30.'70

+27.87

+12.11

+13.51

+16.44

+20.55

+14.06

+13.02

+1.64

+2.05

+12.09

+10.77

+3.03

+0.56

+0.35

+24.66

+1.22

+0.83

+0.58

+0.73

+24.41

+20.64

+0.49

+0.69

-1.89

-1.89

+0.81

+0.58

-1.75

-1.75

+0.98

+1.67

+1.67

+0.59

+0.62

+0.70

+0.51

+31.78

+15.20

-1.09

-0.73

-1.07

-1.25

-0.68

-0.53

+0.62

+0.64

+0.60

+0.60

+7.13

+6.89

+7.69

+6.76

+6.80

+7.63

+1.80

+1.85

+1.00

+1.02

+31.55

+8.73

+0.67

+0.56

-1.13

-1.20

+1.69

+1.69

+25.66

+0.70

+0.70 EXT EXT UTIL 09C TEH 09C TEH TEC TEH TEH TEC TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC WAR FB5 FB5 WAR TEC TEH TEC TEH TEH TEC TEC TEH WAR FB5 FB5 WAR TEH TEC TEC TEH WAR FB8 FB8 WAR TEC TEH WAR FB4 FB4 WAR TEC TEH TEC TEH TEC TEH WAR FB4 FB4 WAR TEC TEH WAR FB4 FB5 WAR TEC TEH WAR TEC TEH WAR FB2 FB3 WAR TEC TEH WAR TEC TEH WAR FB4 FB5 WAR TEC TEH WAR FB7 FB7 WAR TEC TEH WAR 09H FB3 WAR TEC TEH WAR TEC TEH TEH TEC FB4 FB4 WAR TEC TEH WAR TEC TEH WAR FB5 FB5 FB3 FB3 WAR TEC TEH WAR FB3 FB3 WAR TEC TEH WAR FB3 FB3 WAR TEC TEH WAR TEC TEH FB3 FB4 FB3 FB4 TEC TEH FB3 FB4 FB3 FB4 TEC TEH WAR FB6 FB6 WAR TEC TEH WAR FB4 FB4 WAR TEC TEH TEC TEH FB3 FB3 WAR TEC TEH WAR FB4 FB4 WAR TEC TEH WAR TEC TEH WAR FB3 FB4 WAR TEH TEC TEC TEH WAR FB3 FB3 WAR 1 UTIL 2 CAL #

50 48 26 41 24 33 26 24 28 35 35 53 91 99 24 28 33 100 108 21 76 97 100 108 18 8

100 108 100 108 76 100 106 100 76 106 100 97 100 106 100 6

27 106 100 100 101 106 100 106 100 106 100 20 108 108 18 108 108 76 97 76 106 12 14 106 100 106 100 76 106 19 100 108 Page 1 of 2 LEG HOT HOT HOT COLD HOT COLD HOT HOT HOT COLD COLD COLD COLD COLD HOT HOT COLD HOT HOT COLD HOT COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD HOT HOT HOT HOT COLD HOT HOT HOT COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD HOT HOT PROBE 560BP 560BP 560RD 560RD 560RD 560RD 560RD 560RD 56ORD 560UL 560UL 560RD 560RD 460SI 560RD 560RD 56ORD 560UL 540SI 560UL 560BP 540SI 560UL 540SI 560RD 560RD 56OUL 540SI 560UL 540SI 560BP 560UL 540SI 560UL 560BP 540SI 56OUL 540SI 560UL 540SI 560UL 560RD 560RD 540SI 560UL 56OUL 460SI 540SI 560UL 540SI 560UL 540SI 560UL 560RD 540SI 540SI 560RD 540SI 540SI 560BP 540SI 560BP 540SI 560RD 560RD 540SI 56OUL 540SI 560UL 560BP 540SI 560UL 560UL 540SI Customer Lýame:

c-u re V

4 Unit 2 Re lacement

Framatome ANP Inc.

03/18/02 13:43:39 Customer Name: McGuire - Unit 2 Replacement Component: S/G B Indications of Imperfection QUERY: QueryMl ROW COL VOLTS 106 75 0.12 0.17 107 66 0.10 0.17 108 61 0.26 0.36 DEG 115 0

0 0

0 0

CHN P 2 P 3 P 2 P 3 P 3 P 2 IND TWO TWD TWD TWD TWD TWD

%TW 3

5 2

5 9

10 LOCATION FB6

+1.79 FB6

+1.69 FB3

+0.62 FB3

+0.62 FB4

+1.22 FB4

+0.64 EXT EXT TEC TEH FB6 FB6 TEC TEH FB3 FB3 FB4 FB4 TEC TEH UTIL 1 UTIL 2 WAR WAR WAR WAR WAR WAR Total Tubes

50 Total Records:

80 Page 2 of 2 CAL 76 97 100 108 106 100

  1. LEG HOT COLD HOT HOT HOT HOT PROBE 560BP 540SI 560OUL 540SI 540SI 560UL

McGUIRE UNIT 2 S/G B REPAIR LETTER RFO-02 STEAM GENERATOR B

ROW COL COMMENTS No Tubes To Be Repair Independent QDA Review Analysts:

Carson R. Black III A-*

A.

Prepared & Approved By:

Ronald

. Smathers ECT Concurrence

Framatome ANP Inc.

Customer Name: McGuire - Unit 2 Replacement Indications of Imperfection ROW 1

1 2

7 11 13 27 27 43 47 48 48 49 49 51 53 54 54 54 56 57 57 58 58 58 58 59 60 61 61 61 61 62 62 63 63 64 65 65 66 66 68 68 68 68 68 68 69 71 71 72 75 78 80 80 80 COL 28 128 11 6

52 128 30 44 60 50 71 77 34 46 86 94 67 75 91 61 82 90 51 79 89 91 92 91 64 80 90 92 89 91 60 92 91 54 90 89 91 15 49 53 63 85 91 90 64 "88 73 66 67 45 67 79 03/18/02 13:47:57 Component: S/G C Page 1 of 3 VOLTS 1.22 11.08 1.16 1.16 0.15 1.09 0.85 0.15 0.12 0.16 0.23 1.25 0.04 0.15 0.23 0.16 0.22 0.16 0.22 0.17 0.28 0.19 0.22 0.14 0.07 0.17 0.20 0.09 0.21 0.35 0.10 0.17 0.18 0.33 0.26 0.14 0.26 0.18 0.22 0.17 0.22 0.28 0.15 0.17 0.18 0.14 0.16 0.10 0.17 0.11 0.19 0.12 0.17 0.49 0.24 0.18 0.17 0.15 0.29 0.12 0.15 0.11 0.46 0.22 0.25 0.16 0.10 0.08 0.16 0.06 0.42 0.58 0.38 0.14 0.25 DEG 257 179 65 258 86 259 78 86 84 87 0

67 0

0 86 72 79 74 0

0 0

0 0

0 65 0

0 0

55 0

0 0

56 54 59 59 0

0 0

0 52 50 61 52 0

0 60 50 0

51 51 54 80 50 0

0 0

0 56 58 0

0 0

165 0

27 0

135 0

70 109 0

133 0

CHN 7

1 6

7 6

7 6

6 6

6 P 2 6

P 2 P 3 6

6 6

6 P 2 P 2 P 3 P 2 P 3 P 2 7

P 2 P 3 P 2 P 3 7

P 2 P 2 P 3 7

7 7

7 P 2 P 3 P 2 P 3 7

7 7

7 P 2 P 3 7

7 P 2 7

7 7

6 6

P 2 P 2 P 2 P 2 7

7 P 2 P 3 P 2 P 3 P 2 P 3 P 2 P 3 P 2 6

P 3 P 2 P 3 P 2 IND PLP DNT ADI PLP ADI PLP HNI HNI HNI HNI TWD HNI TWD TWD ADI ADI HNI HNI TWD TWD TWD TWD TWD TWD PLP TWD TWD TWD TWD PLP TWD TWD TWD PLP PLP PLP PLP TWD TWD TWD TWD PLP PLP PLP PLP TWD TWD PLP PLP TWD PLP PLP PLP HNI HNI TWD TWD TWD TWD PLP PLP TWD

  • TWD TWD
  • TWD
  • TWD
  • TWD
  • TWD TWD
  • TWD ADI 3 TWO
  • TWD TWD
  • TWD

%TW LOCATION 07H

+3.64 CBH

+6.23 04C

+32.04 06H

+7.82 01C

+7.14 06C

+20.44 03H

+13.06 TO+24.71 01H

+25.53 01H

+23.64 01H

+5.69 6

FB4

+0.56 01H

+20.16 1

FB5

+1.59 2

FB5

+1.49 02H

+21.67 02H

+19.11 02C

+7.74 02C

+8.60 5

FB4

-1.60 4

FB5

+1.63 4

FB5

+1.68 5

FB4

-1.63 4

FB4

-1.66 3

FB4

+0.97 TSC

+11.47 5

FB5

+1.65 3

FB5

+1.53 2

FB3

-1.57 3

FB3

-1.52 TSC

+11.50 3

FB4

-1.20 4

FB5

+1.54 3

FB5

+1.54 TSC

+11.55 TSC

+11.45 TSC

+11.50 TSC

+11.66 5

FB4

-1.69 4

FB4

-1.80 4

FB5

-0.94 3

FB5

-1.04 TSC

+11.56 TSC

+11.46 TSC

+11.53 TSC

+11.42 4

FB5

+0.80 2

FB5

+0.64 TSC

+11.52 TSC

+11.68 3

FB5

+0.82 TSC

+11.49 TSC

+11.50 TSC

+11.47 02H

+19.14 TSH

+14.81 5

FB5

-0.60 5

FB4

+1.07 4

FBS

-1.71 7

FB5

+0.94 TSC

+11.47 TSC

+11.56 3

FB5

+1.19 9

FBS

+1.51 6

FB5

+1.42 6

FB4

-0.97 4

FB4

-0.98 2

FB4

-1.18 2

F84

-1.01 4

FB5

-0.90 1

FB5

-0.93 08H

+32.97 13 FB5

+1.35 10 FB5

+1.22 3

FB4

-1.86 6

FB4

-1.68 EXT EXT 09C TEH 09C TEH CBC TEC 09C TEH TEC TEH TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC FB5 FB5 TEC TEH TEC TEH TEC TEH TEC TEH "TEH TEC TEH TEC FB5 FB5 TEC TEH FB4 FB4 TEH TEC TEH TEC TEC TEH FB5 FB5 TEN TEC FB3 FB3 TEN TEC TEC TEH TEN TEC FB5 FB5 TEN TEC TEH TEC TEH TEC TEH TEC TEC TEN FB4 FB4 TEN TEC FB5 FB5 TEN TEC TEN TEC TEN TEC TEH TEC TEC TEN FB5 FBS TEH TEC TEH TEC TEC TEH TEH TEC TEN TEC TEN TEC TEC TEH TEC TEN TEC TEH TEC TEN TEC TEH TEH TEC TEN TEC TEN TEC TEC TEH FBS FB5 TEC TEN FB4 FB4 TEC TEN

£B4 FB4 TEC TEN FB5 FB5 TEC TEN TEC TEH FB5 FB5 TEC TEH FB4 FB4 TEC TEN UTIL 1 UTIL 2 WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR CAL #

38 46 73 36 34 31 16 30 30 62 84 56 103 104 18 18 32 32 103 103 104 84 102 103 49 84 104 103 104 51 84 103 104 51 49 49 47 84 102 103 104 51 47 51 49 84 104 49 47 84 51 51 49 18 18 84 84 84 103 47 51 90 102 90 100 90 100 90 100 90 74 100 90 100 90 LEG HOT HOT COLD HOT HOT COLD HOT HOT HOT HOT HOT HOT COLD HOT HOT HOT HOT HOT COLD COLD HOT HOT HOT COLD COLD HOT HOT COLD HOT COLD HOT COLD HOT COLD COLD COLD COLD HOT HOT COLD HOT COLD COLD COLD COLD HOT HOT COLD COLD HOT COLD COLD COLD HOT HOT HOT HOT HOT COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 560BP 560BP 560RD 560BP 560RD 560RD 560RD 560RD 560RD 560UL 560BP 560UL 56ORD 520SI 560RD 560RD 560RD 560RD 560RD 560RD 520SI 560BP 520SI 560RD 560RD 560BP 520SI 560RD 520SI 560RD 560BP 560RD 520SI 560RD 560RD 560RD 560RD 560BP 520SI 560RD 520SI 56ORD 560RD 560RD 56ORD 560BP 520SI 560RD 560RD 560BP 560RD 560RD 560RD 560RD 560RD 560BP 560BP 560BP 560RD 56ORD 560RD 560BP 520SI 560BP 540SI 560BP 540SI 560BP 540SI 560BP 560BP 540SI 560BP 540SI 560BP

Framatome ANP Inc.

03/18/02 13:47:57 Customer Name: McGuire - Unit 2 Replacement Component:

S/G C Indications of QUERY: QueryMl ROW COL VOLTS 81 64 0.39 0.21 82 61 0.08 0.03 82 79 0.08 0.19 82 85 0.13 0.24 86 65 0.12 0.03 86 79 0.11 0.20 86 89 0.10 0.09 87 84 0.08 88 85 0.15 0.21 90 61 0.19 0.13 90 117 0.84 92 73 0.15 0.18 93 80 0.15 0.19 94 87 0.14 0.23 95 76 0.18 0.13 96 83 0.23 0.12 98 79 0.16 98 85 0.21 0.29 98 89 0.14 99 86 0.32 0.28 101 80 0.25 0.30 102 77 0.27 0.19 104 57 1.15 105 78 0.17 105 84 0.12 0.23 107 78 0.08 0.17 107 80 0.10 0.17 108 75 0.10 0.10 110 77 0.09 0.13 110 79 0.06 0.05 110 91 0.20 0.07 111 80 0.14 0.07 0.03 112 73 2.63 1.56 113 72 0.72 2.18 114 83 0.12 0.07 115 76 0.13 0.12 Imperfection DEG 15 0

12 0

15 0

56 0

166 0

ill 0

34 0

0 151 0

0 0

61 133 0

163 0

23 0

44 0

85 0

83 159 0

82 124 0

146 0

43 0

7-7 0

131 0

196 0

163 0

8 0

0 0

8 0

71 0

17 169 0

144 63 52 144 92 0

99 0

CHN P 3 P 2 P 3 P 2 P 3 P 2 P 2 P 3 P 3 P 2 P

3 P 2 P 3 P

2 P 2 P 3 P 2 P 2 P 3 6

P 3 P 2 P 3 P 2 P 3 P 2 P 3 P 2 P 2 P 3 6

P 3 P 2 6

P 3 P 2 P 3 P 2 P 3 P 2 6

P 2 P 3 P 2 P 3 P 2 P

3 P 2 P 3 P 2 P 3 P 2 P

3 P 2 P

3 P 2 P 3 P

3 P 2 7

7 7

7 P 3 P 2 P 3 P 2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD HNI TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD ADI TWD TWD ADI TWD TWD TWD TWD TWD TWD HNI TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD PLP PLP PLP PLP TWD TWD TWD TWD

%TW 9

6 2

1 2

5 3

4 3

1 3

5 3

2 2

4 5

5 5

4 5

5 5

4 6

6 3

6 5

7 7

10 7

8 8

9 5

4 4

6 2

4 3

4 3

3 2

3 2

1 6

2 4

2 1

4 2

4 3

LOCATI FB4 FB4 FB5 FB5 FB4 FB4 FB5 FB5 FB5 FB5 FB4 FB4 FB4 FB4 FB5 FB4 FB4 FB4 FB4 09H FB5 FB5 FB7 FB7 FB5 FB5 FB4 FB4 FB5 FB5 01H FB5 FB5 01H FB4 FB4 FB4 FB4 FB3 FB3 06C FB4 FB4 FB4 FB3 FB3 FB7 FB7 FB4 FB4 FB3 FB3 FB7 FB7 FB4 FB4 FB4 FB4 FB4 TSH TSH TSH TSH FB4 FB4 FB3 FB3 ON

+1.28

+1.22

-1.55

-1.48

-1.58

-1.60

-0.71

-0.84

-0.61

-0.63

-1.79

-1.68

+1.51

+1.39

+0.76

-1.57

-1.71

-0.93

-1.05

+10.17

-0.76

-0.79

+1.79

+1.86

+1.48

+1. 68

-0.70

-0.73

-1.31

-1.26

+19.29

-1.54

-1.69

+20.53

+0.75

+0.68

+0.77

+0.58

+0.56

+0.52

+29.03 TO+

+1.33

+0.74

+0.68

+1.65

+1.86

+1.66

+1.86

-1.68

-1.75

+0.58

+0.71

+0.59

+0.58

+1.30

+1.37

-1.05

+1.21

+1.34

+13.87

+13.65

+13.91

+13.81

-1.50

-1.47

+1.59

+1.80 EXT EXT UTIL 1 FB4 FB4 WAR TEC TEH WAR FBS FB5 WAR TEC TEH WAR FB4 FB4 WAR TEC TEH WAR TEC TEH WAR FB5 FB5 WAR FB5 FB5 WAR TEC TEH WAR FB4 FB4 WAR TEC TEH WAR FB4 FB4 WAR TEC TEH WAR TEC TEH WAR FB4 FB4 WAR TEC TEH WAR TEC TEH WAR FB4 FB4 WAR TEH TEC HR FB5 FB5 WAR TEC TEH WAR FB7 FB7 WAR TEC TEH WAR FB5 FB5 WAR TEC TEH WAR FB4 FB4 WAR TEC TEH WAR TEC TEH WAR FB5 FB5 WAR TEH TEC FB5 FB5 WAR TEC TEH WAR TEH TEC FB4 FB4 WAR TEC TEH WAR FB4 FB4 WAR TEC TEH WAR FB3 FB3 WAR TEC TEH WAR 16.71 TEC TEH TEC TEH WAR FB4 FB4 WAR TEC TEH WAR FB3 FB3 WAR TEC TEH WAR FB7 FB7 WAR TEC TEH WAR FB4 FB4 WAR TEC TEH WAR FB3 FB3 WAR TEC TEH WAR FB7 FB7 WAR TEC TEH WAR FB4 FB4 WAR TEC TEH WAR FB4 FB4 WAR FB4 FB4 WAR TEC TEH WAR TSH 01H TEH TEC TEC TEH TSH 01H FB4 FB4 WAR TEC TEH WAR FB3 FB3 WAR TEC TEH WAR UTIL 2 CAL $

100 90 100 90 100 90 90 104 100 90 100 90 100 90 90 100 90 90 117 11 98 90 96 90 96 90 96 90 90 117 23 96 90 17 96 90 96 90 96 90 68 90 96 90 96 90 96 90 96 90 96 90 96 90 96 90 96 96 90 92 21 64 92 96 90 96 90 Total Tubes

92 Total Records:

142 Page 2 of 3 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD HOT HOT COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD HOT HOT HOT HOT HOT HOT PROBE 540SI 560BP 540SI 560BP 540SI 560BP 560BP 520SI 540SI 560BP 540SI 560BP 540SI 560BP 560BP 540SI 560BP 560BP 540SI 560RD 540SI 560BP 540SI 560BP 540SI 560BP 540SI 560BP 560BP 540SI 560RD 540SI 560BP 560RD 540SI 560BP 540SI 560BP 540SI 560BP 560BP 560BP 540SI 560BP 540SI 560BP 540SI 560BP 540SI 560BP 540SI 560BP 540SI 560BP 540SI 560BP 540SI 540SI 560BP 540SI 560RD 560BP 540SI 540SI 560BP 540SI 560BP

Framatome ANP Inc.

03/18/02 13:47:57 Customer Name: McGuire - Unit 2 Replacement Component: S/G C Page 3 of 3 Indications of Imperfection QUERY:

QueryMl ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

McGUIRE UNIT 2 S/G C REPAIR LETTER RFO-02 STEAM GENEATO ROW COL C

COMMENTS No Tubes To Be Repair Independent QDA Review Analysts:

Carson R. Black i f,*

Prepared & Approved By:

Ronald D. Smathers zz ECT Concurrence:

STEAM GENERATOR TUBE REPAIR LIST Station/Unit/Outage MNS2 EOC14 ROW COL Date 3/12/02 REVISION 0 REPAIR METHOD HL CL COMMENTS STEAM GENERATOR A

B C

D APPROVALS:

SGME Engin ring

,6~ (1 ECT Coordinator or Designee KEY TO REPAIRS P -

Inconel 690 Rolled Mechanical Plug ST-Rolled Plug with a Wire Rope Stabilizer (Length)

RWP - Remote Welded Plug MWP -Manual Welded Plug SP-Sleeve Plug ROLL-Upper Tube Sheet Re-roll Not Inspected No Tubes Require Repair No Tubes Require Repair Not Inspected