ROCHESTER GAS AND ELECTRIC CORPORATION
- 89 EAST AVENUE, ROCHESTER, N. Y 14649-0001
"-ý AREA CODE 716 546-2700 March 28, 2002 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Attn: Mr. Robert Clark (Mail Stop O-8-E9)
Project Directorate I-1
Subject:
Revision to Emergency Plan Implementing Procedures R.E. Ginna Nuclear Power Plant Docket No. 50-244 Gentlemen:
In accordance with 10 CFR 50.4(b)(5), enclosed is a revision to a Ginna Station Emergency Plan Implementing Procedure (EPIP).
We have determined, per the requirements of 10 CFR 50.54(q), that these procedure changes do not decrease the effectiveness of our Nuclear Emergency Response Plan.
Very truly yours, Richard J. Watts Manager, Nuclear Training Department Enclosures xc:
USNRC Region 1 (2 copies of letter and 2 copies of each procedure)
Resident Inspector, Ginna Station (1 copy of letter and 1 copy of each procedure)
RG&E Nuclear Safety and Licensing (1 copy of letter)
Dr. Robert C. Mecredy (2 copies of letter only)
PSP/jtw
U.S. Nuclear Regulatory Commission March 28, 2002 Page 2 of 2 PROCEDURE EPIP 5-10 REVISION NUMBER 6
ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER a3 PROCEDURE NO.
EPIP 5-10 REV. NO.
6 EMERGENCY RESPONSE DATA SYSTEM (ERDS)
RESP-ONSIBLE M A
R J&-
09 EFFECTIVE DATE CATEGORY 1.0 THIS PROCEDURE CONTAINS 72 PAGES
EPIP 5-10:1 EPIP 5-10 EMERGENCY RESPONSE DATA SYSTEM (ERDS)
1.0 PURPOSE
1.1 Defines (1) administrative controls to the Plant Process Computer System (PPCS) data points sent to the Nuclear Regulatory Commission (NRC) (2) administrative controls for PPCS data communications protocol and (3) testing of the data link.
2.0 RESPONSIBILITY
2.1 The Onsite Emergency Planner (OEP) and the Ginna Computer Systems will be responsible for any testing of the data link or changes to the Data Point Library (DPL).
3.0 REFERENCES
3.1 NUREG-1394 Emergency Response Data System (ERDS) Implementation
4.0 PRECAUTIONS
4.1 None.
5.0 PREREQUISITES
5.1 None.
6.0 ACTIONS
6.1 DATA POINT LIBRARY (DPL) 6.1.1 The DPL is detailed in Attachment 2. Any changes to the DPL will be routed through the Onsite Emergency Planner and Ginna Computer Systems.
These changes will be sent to the NRC within 30 days of distribution.
6.1.2 The NRC can only accept 8 quality codes. The PPCS has 21 quality codes. fits each one of the 21 PPCS quality codes into one of the 8 NRC quality codes.
6.2 COMMUNICATION PROTOCOL 6.2.1 The NRC shall be notified of proposed PPCS data communications protocol changes prior to installation.
EPIP 5-10:2 6.2.2 Any changes to communications protocol will be routed through the Onsite Emergency Planner and Ginna Computer Systems.
6.3 QUARTERLY TESTING 6.3.1 Testing will be performed as directed by the NRC. Quarterly testing of the ERDS data link will normally be conducted on the first Wednesday of the quarter (i.e. the first Wednesday in January, April, July, October).
NOTE:
THE TEST SHOULD BE CONDUCTED BETWEEN THE HOURS OF 0800 - 1600.
6.3.2 Testing will verify operability of the ERDS link. The test will be conducted as follows:
6.3.2.1 Inform the Control Room that Ginna will be sending plant PPCS parameters to the NRC per EPIP 5-10.
6.3.2.2 Call the NRC Operations Center at (301) 415-5015 and ask if Ginna can begin testing of the ERDS link.
6.3.2.3 Establish the ERDS link by:
- 1.
From the top menu, select "Emergency Plan Menu" on a PPCS terminal.
- 2.
Select "NRC ERDS Data Link".
- 3.
Select "Initiate transmission".
6.3.2.4 Observe that the PPCS establishes the ERDS link.
6.3.2.5 Have the NRC Operations Center disconnect the Ginna ERDS link.
6.3.2.6 Ensure that the PPCS recognizes that the ERDS link has been disconnected. Ensure that the PPCS automatically re-establishes the ERDS link.
6.3.2.7 Once the link has been re-established, inform the NRC Operations Center that Ginna will be sending ERDS data and that the NRC can terminate the link after 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.
EPIP 5-10:3
7.0 ATTACHMENTS
1 - ERDS Data Quality Codes 2.- Data Point Library (DPL)
EPIP 5-10:4 Page 1 of 3 ERDS DATA QUALITY CODES NOTE:
THE NRC ERDS HAS 8 "QUALITY TAGS" AVAILABLE TO IDENTIFY THE QUALITY OF DATA BEING SENT FROM A PLANT. THIS NECESSITATES THAT EACH PPCS DATA QUALITY BE CONVERTED INTO ONE OF THE 8 NRC QUALITIES.
Table 1 defines the 8 NRC data qualities tags.
Table 2 identifies PPCS qualities, and the converted quality tag being sent from PPCS to the NRC ERDS.
Table 1:
NRC ERDS QUALITY TAG DEFINITIONS The following is based on NUREG-1 394, Rev. 1 "Emergency Response Data System (ERDS) Implementation", Appendix B.
NRC NRC NRC Qual Name Description 0
Good Value is within range tolerance for discreet points or input points are within tolerance for composed points.
1 Off-scan Point is currently out-of-service.
2 Suspect Value is not bad yet should not be considered good.
This quality will occur primarily on composed values when enough good inputs are present to allow the calculation to be made yet a bad quality on other inputs may make the result questionable.
3 Bad Value is not within tolerance for discreet points or calculation of a composed point may not be made due to the qualities of its inputs.
4 Unknown No quality indicator available.
5 Operator Value has been manually entered, Entered overriding the discreet or composed value.
6 High Alarm Value is in high alarm.
7 Low Alarm Value is in low alarm.
,EPIP 5-10:5 Table 2: PPCS DATA QUALITY CODE CONVERSION TO NRC ERDS QUALITY TAG Page 2 of 3 NRC PPCS PPCS PPCS PPCS Qual Mapping Name Color Description 0
0 GOOD Base Color Point is normal.
0 1
GOOD Green Point is normal.
2 2
SUSP Green Point is Suspect.
2 3
POOR Yellow SPDS point is Suspect.
5 4
SUB Green Substitute value has been entered.
2 5
ALRM Red SPDS point is in Alarm.
3 6
DBAD White Data Acquisiton is Bad.
3 7
LMV White Data Failed - Low MilliVolts.
3 8
HMV White Data Failed - High Millivolts 3
9 BAD White Value is BAD.
1 10 DEL White Point is Off Scan.
0 11 GOOD Green Value is Good (Alarms Not Defined) 0 12 LWRN Yellow UnAcknowleged Event Alarm Low.
0 13 LWRN Yellow Acknowleged Event Alarm Low.
0 14 HWRN Yellow UnAcknowleged Event Alarm High.
0 15 HWRN Yellow Acknowleged Event Alarm High.
0 16 LWRN Yellow UnAcknowleged Attention Alarm Low.
0 17 LWRN Yellow Acknowleged Attention Alarm Low.
0 18 HWRN Yellow UnAcknowleged Attention Alarm High.
0 19 HWRN Yellow Acknowleged Attention Alarm High.
0 20 LWRN Yellow UnAcknowleged Caution Alarm Low.
0 21 LWRN Yellow Acknowleged Caution Alarm Low.
0 22 HWRN Yellow UnAcknowleged Caution Alarm High.
0 23 HWRN Yellow Acknowleged Caution Alarm High.
7 24 LALM Red Unacknowleged Severe Alarm Low.
7 25 LALM Red Acknowleged Severe Alarm Low.
6 26 HALM Red Unacknowleged Severe Alarm High.
6 27 HALM Red Acknowleged Severe Alarm High.
2 28 LWR*
Yellow UnAck'ed Event Alarm Low SUSPECT.
2 29 LWR*
Yellow Ack'ed Event Alarm Low SUSPECT.
2 30 HWR*
Yellow UnAck'ed Event Alarm High SUSPECT.
2 31 HWR*
Yellow Ack'ed Event Alarm High SUSPECT.
2 32 LWR*
Yellow UnAck'ed Attention Alarm Low SUSPECT.
2 33 LWR*
Yellow Ack'ed Attention Alarm Low SUSPECT.
2 34 HWR*
Yellow UnAck'ed Attention Alarm High SUSPECT 2
35 HWR*
Yellow Ack'ed Attention Alarm High SUSPECT.
2 36 LWR*
Yellow UnAck'ed Caution Alarm Low SUSPECT.
2 37 LWR*
Yellow Ack'ed Caution Alarm Low SUSPECT.
2 38 HWR*
Yellow UnAck'ed Caution Alarm High SUSPECT.
2 39 HWR*
Yellow Ack'ed Caution Alarm High SUSPECT.
7 40 LAL*
Red Unack'ed Severe Alarm Low SUSPECT.
7 41 LAL*
Red Ack'ed Severe Alarm Low SUSPECT.
6 42 HAL*
Red Unack'ed Severe Alarm High SUSPECT.
6 43 HAL*
Red Ack'ed Severe Alarm High SUSPECT 6
44 ALRM Red Unacknowleged Digital Alarm 6
45 ALRM Red Acknowleged Digital Alarm 6
46 ALR*
Red Unack'ed Digital Alarm SUSPECT 6
47 ALR*
Red Ack'ed Digital Alarm SUSPECT 0
48 REDU Red Acknowleged Redundant Alarm 0
49 RATE Yellow Acknowleged Rate Alarm 0
50 RATE Yellow Unacknowleged Rate Alarm
EPIP 5-10:6 Page 3 of 3 0
51 DALM Green Deleted from alarming 0
52 DAL*
Green Deltered from Alarming and Suspect 3
53 LENG Red Failed EU-Range Low 3
54 HENG Red Failed EU-Range High 3
55 DBAD White Data Acq BAD - UNACK 3
56 LMV White Failed MV-Range Low UNACK 3
57 HMV White Failed MV-Range High UNACK 3
58 BAD White Bad UNACK 3
59 LENG Red Failed EU - Range Low UNACK 3
60 HENG Red Failed EU - Range High UNACK 0
61 GOOD Green Normal GOOD UNACK 2
62 POOR Green POOR UNACK 0
63 REDU Green REDUNDANT UNACK 2
64 SUSP Green SUSPECT UNACK 5
65 SUB Green MANUAL UNACK 1
66 DEL White Off Scan UNACK
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
ROCHESTER GAS & ELEC EMERGENCY RESPONSE DATA POINT LIB Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Plant Point ID:
Plant Specific Point
Description:
Generic/Condensed
Description:
Analog/Digital:
Engineering Units or Digital States:
Engineering Units Conversion:
Minimum Instrument Range:
Maximum Instrument Range:
Zero Point
Reference:
Reference Point Notes:
Process or Sensor:
Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
EPIP 5-10:7 Page 1 of 66 AVERAGE NUCLEAR POWER NUCLEAR INSTRUMENTS POWER RANGE ANALOG NONE 0%
120%
N/A N/A PROCESS 4
AVERAGED NIS TUBES-CONTAINMENT REACTOR CAVITY 108% Power range hi flux 103% Rod stop 24% Power range Lo range trip (Block >8%)
N/A N/A N/A N/A N/A
- 2/4 Power range channels at 108% power will initiate a reactor trip.
- 1/4 power range channels at 103% will block auto/man rod withdrawal
- 2/4 power range channels at 24% will initiate a reactor trip. This trip is blockable above 8% by manual action.
.TRIC CORPORATION DATA SYSTEM (ERDS)
RARY (DPL) 9/5/97 GIl (Ginna)
N/A NI POWER RANGE NP
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:8 Page 2 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gil (Ginna)
N/A imeter:
NI INTER RNG N35 lint
Description:
INTERMEDIATE RANGE DETECTOR N-35 sed
Description:
NUCLEAR INSTRUMENT INTER RANGE ANALOG s or Digital States:
AMP s Conversion:
N/A nent Range:
1.OE-1 1 AMPS nent Range:
1.OE-3 AMPS ence:
N/A Notes:
N/A or:
SENSOR Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
1 N/A NIS TUBES-CONTAINMENT REACTOR CAVITY 25% Reactor power (current equivalent)
N/A N/A N/A N/A N/A 1 of 2 intermediate range channels at 25% power (current equivalent) will initiate a reactor trip. This trip is blockable above 8% power by manual action.
2 Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Conden:
Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrum Maximum Instrur Zero Point Refer Reference Point Process or Sens
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:9 Page 3 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gi1 (Ginna)
N/A Lmeter:
NI INTER RNG N36 lint
Description:
INTERMEDIATE RANGE DETECTOR N-36 sed
Description:
NUCLEAR INSTRUMENTS INTER RANGE ANALOG s or Digital States:
AMPS s Conversion:
N/A nent Range:
1.OE-11 AMPS nent Range:
1.0E-3 AMPS ence:
N/A Notes:
N/A or:
SENSOR Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
1 N/A NIS TUBES-CONTAINMENT REACTOR CAVITY 25% Reactor power (current equivalent)
N/A N/A N/A N/A N/A 1 of 2 intermediate range channels at 25% power (current equivalent) will initiate a reactor trip. This trip is blockable above 8% power by manual action.
3 Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Conden, Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrun Maximum Instrur Zero Point Refer Reference Point Process or Sens
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:10 Page 4 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gil (Ginna)
N/A meter:
NI SOURCE RANGE N31 int
Description:
SOURCE RANGE DETECTOR N-31 sed
Description:
NUCLEAR INSTRUMENTS SOURCE RANGE ANALOG s or Digital States:
CPS s Conversion:
N/A ent Range:
1.OE+0 CPS "nent Range:
1.OE+6 CPS ence:
N/A Notes:
N/A or:
SENSOR Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
1 N/A NIS TUBES-CONTAINMENT REACTOR CAVITY 1 E+5 CPS Source range hi flux reactor trip 1 E-1 0 AMPS intermediate range 5E-11 AMPS intermediate range N/A N/A N/A 1 E-1 0 AMPS in the intermediate range permits block of source range hi flux trip (manual action). 5E-1 1 AMPS in the intermediate range reinstates the source range high volts (automatic action) 4 Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Pc Generic/Conden Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrum Maximum Instruri Zero Point Referi Reference Point Process or Sens
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:11 Page 5 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gil (Ginna)
N/A meter:
NI SOURCE RANGE N32 int
Description:
SOURCE RANGE DETECTOR N-32 sed
Description:
NUCLEAR INSTRUMENTS SOURCE RANGE ANALOG ts or Digital States:
CPS ts Conversion:
N/A nent Range:
1.OE+O CPS ment Range:
1.OE+6 CPS rence:
N/A Notes:
N/A or:
SENSOR Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
1 N/A NIS TUBES-CONTAINMENT REACTOR CAVITY 1 E+5 CPS Source range hi flux reactor trip 1 E-10 AMPS intermediate range 5E-1 1 AMPS intermediate range N/A N/A N/A 1 E-1 0 AMPS in the intermediate range permits block of source range hi flux trip (manual action). 5E-11 AMPS in the intermediate range reinstates the source range high volts (automatic action) 5 Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Conden.
Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrun Maximum Instrur Zero Point Refer Reference Point Process or Sens
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11) 12)
EPIP 5-10:12 Page 6 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gi1 (Ginna)
N/A ameter:
REAC VES LEV LRV
)int
Description:
REACTOR VESSEL AVERAGE LEVEL sed
Description:
REACTOR VESSEL WATER LEVEL ANALOG Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Conden Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrur Maximum Instrur 1% = 4.415 INCHES 0
Pumps on Pumps off 0% void fraction 0% level 100% void fraction 107.6% level
- 13)
Zero Point
Reference:
BOT I I M UO-VlESL - Tor evel ina*ication
- 14)
Reference Point Notes:
N/A
- 15)
Process or Sensor:
PROCESS
- 16)
Number of Sensors:
2
- 17)
How Processed:
AVERAGED
- 18)
Sensor Locations:
CONTAINMENT BASEMENT LEVEL
- 19)
Alarrn/Trip Setpoints:
N/A
- 20)
NI Detector Power Supply Cut-Off Power Level:
N/A
- 21)
NI Detector Power Supply Turn-On Power Level:
N/A
- 22)
Instrument Failure Mode:
N/A
- 23)
Temperature Compensation for DP Transmitters:
N/A
- 24)
Level Reference Leg:
WET
- 25)
Unique System
Description:
The control board RVLIS indicator has two scales indicating % void fraction with RCP's "on" and % level with RCP's "off". A reactor vessel level of 77% corresponds to a collapsed liquid level at the top of the core, including allowance for normal channel accuracy. This value is used as an alternate Sl reinitiation criteria when RCS subcooling and PZR level are not adequate. A reactor vessel level of 52% corresponds to a collapsed liquid level which is 3.5 feet above the bottom of the core. This value is used as an indication of inadequate core cooling when no RCP is running.
6 ts or Digital States:
ts Conversion:
nent Range:
ment Range:
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 7 EPIP 5-10:13 Page 7 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
GIl (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
TEMP CORE EX Plant Point ID:
TCMAX Plant Specific Point
Description:
HOTTEST INCORE TC TEMPERATURE Generic/Condensed
Description:
HOTTEST TEMPERATURE AT CORE EXIT Analog/Digital:
ANALOG Engineering Units or Digital States:
DEGF Engineering Units Conversion:
N/A Minimum Instrument Range:
0 F Maximum Instrument Range:
2300 F Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
PROCESS Number of Sensors:
36 How Processed:
HOTTEST OF 36 INCORE TC'S Sensor Locations:
INSIDE REACTOR VESSEL Alarm/Trip Setpoints:
TSAT Alarm NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
If any incore TC temperature reaches saturation temperature, a computer alarm will be generated.
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
Date:
Reactor Unit:
Data Feeder:
NRC ERDS ParE Plant Point ID:
Plant Specific Po Generic/Conden.
Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrun Maximum Instrur Zero Point Refer Reference Point Process or Sens Number of Sens How Processed:
Sensor Location Alarm/Trip Setpc NI Detector Pow NI Detector Pow Instrument Failu Temperature Co Level Reference Unique System I 8
EPIP 5-10:14 Page 8 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gil (Ginna)
N/A imeter:
SUB MARGIN TSUBTC
)int
Description:
INCORE TC SUBCOOLED MARGIN sed
Description:
SATURATION TEMP-HIGHEST CET ANALOG
- s or Digital States:
DEGF
- s Conversion:
N/A ient Range:
-50 F ment Range:
300 F fence:
N/A Notes:
N/A or:
PROCESS ors:
2 D/F s:
CETS: INSIDE REAC VESSEL RCS PRESS: CV INT LEVEL ints:
N/A er Supply Cut-Off Power Level:
N/A er Supply Tum-On Power Level:
N/A re Mode:
N/A mpensation for DP Transmitters:
N/A Leg:
N/A
==
Description:==
N/A
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 9 EPIP 5-10:15 Page 9 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
Gil (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
CORE FLOW Plant Point ID:
FRCLA Plant Specific Point
Description:
REACTOR COOLANT LOOP A AVG FLOW Generic/Condensed
Description:
TOTAL REACTOR COOLANT FLOW Analog/Digital:
ANALOG Engineering Units or Digital States:
Engineering Units Conversion:
1% = 900 GPM Minimum Instrument Range:
0 Maximum Instrument Range:
110 Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
PROCESS Number of Sensors:
3 How Processed:
AVERAGED Sensor Locations:
CONTAINMENT BUILDING Alarm/Trip Setpoints:
91%
NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
Each reactor coolant pump is rated at 90,000 GPM
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 10 I
EPIP 5-10:16 Page 10 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
GI1 (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
CORE FLOW Plant Point ID:
FRCLB Plant Specific Point
Description:
REACTOR COOLANT LOOP B AVG FLOW Generic/Condensed
Description:
TOTAL REACTOR COOLANT FLOW Analog/Digital:
ANALOG Engineering Units or Digital States:
Engineering Units Conversion:
1% = 900 GPM Minimum Instrument Range:
0 Maximum Instrument Range:
110 Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
PROCESS Number of Sensors:
3 How Processed:
AVERAGED Sensor Locations:
CONTAINMENT BUILDING Alarm/Trip Setpoints:
91%
NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
Each reactor coolant pump is rated at 90,000 GPM
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
ROCHESTER GAS & ELEC EMERGENCY RESPONSE E DATA POINT LIBI Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Plant Point ID:
Plant Specific Point
Description:
Generic/Condensed
Description:
Analog/Digital:
Engineering Units or Digital States:
Engineering Units Conversion:
Minimum Instrument Range:
Maximum Instrument Range:
Zero Point
Reference:
Reference Point Notes:
Process or Sensor:
Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
11 EPIP 5-10:17 Page 11 of 66 TRIC CORPORATION
)ATA SYSTEM (ERDS)
RARY (DPL) 9/5/97 GIl (Ginna)
N/A PRZR LEVEL LPZR PRESSURIZER AVERAGE LEVEL PRIMARY SYSTEM PRESSURIZER LEVEL ANALOG 1% = 2.1 INCHES
-17%
100%
LOWER INSTRUMENT TAP, 35 INCHES FROM BOTTOM OF PRESSURIZER N/A PROCESS 3
AVERAGED CONTAINMENT INTERMEDIATE LEVEL 87% - High level reactor trip, 6.15% low level alarm N/A N/A N/A N/A WET 13% PZR heater cutout and letdown isolation
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 12 EPIP 5-10:18 Page 12 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
Gil (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
RCS PRESSURE Plant Point ID:
PRCS Plant Specific Point
Description:
REACTOR COOLANT SYSTEM AVG PRESS Generic/Condensed
Description:
REACTOR COOLANT SYSTEM PRESSURE Analog/Digital:
ANALOG Engineering Units or Digital States:
PSIG Engineering Units Conversion:
N/A Minimum Instrument Range:
0 PSIG Maximum Instrument Range:
3.OE+3 PSIG Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
PROCESS Number of Sensors:
2 How Processed:
AVERAGED Sensor Locations:
CONTAINMENT INTERMEDIATE LEVEL Alarm/Trip Setpoints:
High alarm 2340, Low alarm = 1750 NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
N/A
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
I 13 ROCHESTER GAS & ELEC EMERGENCY RESPONSE D DATA POINT LIBF Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Plant Point ID:
Plant Specific Point
Description:
Generic/Condensed
Description:
Analog/Digital:
Engineering Units or Digital States:
Engineering Units Conversion:
Minimum Instrument Range:
Maximum Instrument Range:
Zero Point
Reference:
Reference Point Notes:
Process or Sensor:
Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
EPIP 5-10:19 Page 13 of 66 TRIC CORPORATION
)ATA SYSTEM (ERDS) 3ARY (DPL) 9/5/97 GI1 (Ginna)
N/A SG LEVEL 1/A LSGAWIDE STM GEN A WIDE RNG AVERAGE LEVEL STEAM GENERATOR A WATER LEVEL ANALOG INCHES 1 INCH= 1%
0 520 BOTTOM INSTRUMENT PORT, 12 INCHES ABOVE TUBESHEET N/A PROCESS 3
AVERAGED CONTAINMENT BASEMENT 468 N/A N/A N/A N/A WET TOP OF BUNDLE = 365 INCHES
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
ROCHESTER GAS & ELEC EMERGENCY RESPONSE I DATA POINT LIBI Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Plant Point ID:
Plant Specific Point
Description:
Generic/Condensed
Description:
Analog/Digital:
Engineering Units or Digital States:
Engineering Units Conversion:
Minimum Instrument Range:
Maximum Instrument Range:
Zero Point
Reference:
Reference Point Notes:
Process or Sensor:
Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
14 EPIP 5-10:20 Page 14 of 66 TRIC CORPORATION
)ATA SYSTEM (ERDS)
RARY (DPL) 9/5/97 GI1 (Ginna)
N/A SG LEVEL 2/B LSGBWIDE STM GEN B WIDE RNG AVERAGE LEVEL STEAM GENERATOR B WATER LEVEL ANALOG INCHES 1 INCH= 1%
0 520 BOTTOM INSTRUMENT PORT, 12 INCHES ABOVE TUBESHEET N/A PROCESS 3
AVERAGED CONTAINMENT BASEMENT 468 N/A N/A N/A N/A WET TOP OF BUNDLE = 365 INCHES
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 15 EPIP 5-10:21 Page 15 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
Gi1 (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
SG PRESS 1/A Plant Point ID:
PSGA Plant Specific Point
Description:
STEAM GEN A AVERAGE PRESSURE Generic/Condensed
Description:
STEAM GENERATOR A PRESSURE Analog/Digital:
ANALOG Engineering Units or Digital States:
PSIG Engineering Units Conversion:
N/A Minimum Instrument Range:
0 PGIG Maximum Instrument Range:
1.4E+3 PSIG Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
PROCESS Number of Sensors:
3 How Processed:
AVERAGED Sensor Locations:
INTERMEDIATE BUILDING Alarm/Trip Setpoints:
514 PSIG NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
2 out of 3 S/G pressures at 514 PSIG will initiate a safety injection signal
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 16 EPIP 5-10:22 Page 16 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
GI1 (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
SG PRESS 2/B Plant Point ID:
PSGB Plant Specific Point
Description:
STM GEN B AVERAGE PRESSURE Generic/Condensed
Description:
STEAM GENERATOR B PRESSURE Analog/Digital:
ANALOG Engineering Units or Digital States:
PSIG Engineering Units Conversion:
N/A Minimum Instrument Range:
0 PSIG Maximum Instrument Range:
1;4E+3 PSIG Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
PROCESS Number of Sensors:
3 How Processed:
AVERAGED Sensor Locations:
INTERMEDIATE BUILDING Alarm/Thip Setpoints:
514 PSIG NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
2 out of 3 S/G pressures at 514 PSIG will initiate a safety injection signal.
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:23 Page 17 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gil (Ginna)
N/A imeter:
MN FD FL 1/A FFWA lint
Description:
STM GEN A AVERAGE FEEDWATER FLOW sed
Description:
STM GEN A MAIN FEEDWATER FLOW ANALOG s or Digital States:
KLB/HR s Conversion:
N/A nent Range:
0 KLB/HR ment Range:
3.8E+3 KLB/HR ence:
N/A Notes:
N/A or:
PROCESS Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
3 AVERAGED INTERMEDIATE BUILDING N/A N/A N/A N/A N/A N/A N/A 17 Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Conden:
Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrun Maximum Instrur Zero Point Refer Reference Point Process or Sens
Date:
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:24 Page 18 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gil (Ginna)
N/A Lmeter:
MN FD FL 2/B FFWB iint
Description:
STM GEN B AVERAGE FEEDWATER FLOW sed
Description:
STM GEN B MAIN FEEDWATER FLOW ANALOG s or Digital States:
KLB/HR s Conversion:
N/A nent Range:
0 KLB/HR nent Range:
3.8E+3 KLB/HR ence:
N/A Notes:
N/A or:
PROCESS Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
3 AVERAGED INTERMEDIATE BUILDING N/A N/A N/A N/A N/A N/A N/A 18 Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Conden*
Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrurr Maximum Instrur Zero Point Refer Reference Point Process or Sens
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 19 EPIP 5-10:25 Page 19 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
Gil (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
AX FD FL 1/A Plant Point ID:
FAUXFWA Plant Specific Point
Description:
S/G A TOTAL AUX FEEDWATER FLOW Generic/Condensed
Description:
STM GEN A AUXILIARY FW FLOW Analog/Digital:
ANALOG Engineering Units or Digital States:
GPM Engineering Units Conversion:
N/A Minimum Instrument Range:
0 GPM Maximum Instrument Range:
11.0E+3 GPM Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
PROCESS Number of Sensors:
3 How Processed:
SUM Sensor Locations:
INTERMEDIATE BUILDING BASEMENT Alarm/Trip Setpoints:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
N/A
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 20 EPIP 5-10:26 Page 20 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
GI1 (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
AX FD FL 2/B Plant Point ID:
FAUXFWB Plant Specific Point
Description:
S/G B TOTAL AUX FEEDWATER FLOW Generic/Condensed
Description:
STM GEN B AUXILIARY FW FLOW Analog/Digital:
ANALOG Engineering Units or Digital States:
GPM Engineering Units Conversion:
N/A Minimum Instrument Range:
0 GPM Maximum Instrument Range:
1.OE+3 GPM Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
PROCESS Number of Sensors:
3 How Processed:
SUM Sensor Locations:
INTERMEDIATE BUILDING BASEMENT Alarm/Trip Setpoints:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
N/A
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 21 EPIP 5-10:27 Page 21 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
Gil (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
HL TEMP 1/A Plant Point ID:
T0409A Plant Specific Point
Description:
RCLA HOT LEG TEMPERATURE Generic/Condensed
Description:
STM GEN A INLET TEMPERATURE Analog/Digital:
ANALOG Engineering Units or Digital States:
DEGF Engineering Units Conversion:
N/A Minimum Instrument Range:
0 F Maximum Instrument Range:
700 F Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
SENSOR Number of Sensors:
1 How Processed:
N/A Sensor Locations:
CONTAINMENT: HOT LEG Alarm/Trip Setpoints:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
N/A
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 22 EPIP 5-10:28 Page 22 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
GIl (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
HL TEMP 2/B Plant Point ID:
T0410A Plant Specific Point
Description:
RCLB HOT LEG TEMPERATURE Generic/Condensed
Description:
STM GEN B INLET TEMPERATURE Analog/Digital:
ANALOG Engineering Units or Digital States:
DEGF Engineering Units Conversion:
N/A Minimum Instrument Range:
0 F Maximum Instrument Range:
700 F Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
SENSOR Number of Sensors:
1 How Processed:
N/A Sensor Locations:
CONTAINMENT: B HOT LEG Alarm/Trip Setpoints:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
N/A
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 23 EPIP 5-10:29 Page 23 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
Gil (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
CL TEMP 1/A Plant Point ID:
T0409B Plant Specific Point
Description:
RCLA COLD LEG TEMPERATURE Generic/Condensed
Description:
STM GEN A OUTLET TEMPERATURE Analog/Digital:
ANALOG Engineering Units or Digital States:
DEGF Engineering Units Conversion:
N/A Minimum Instrument Range:
0 F Maximum Instrument Range:
700 F Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
SENSOR Number of Sensors:
1 How Processed:
N/A Sensor Locations:
CONTAINMENT: COLD LEG Alarm/Trip Setpoints:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
N/A
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:30 Page 24 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gil (Ginna)
N/A meter:
CL TEMP 2/B T041 0B int
Description:
RCLB COLD LEG TEMPERATURE sed
Description:
STM GEN B OUTLET TEMPERATURE ANALOG s or Digital States:
DEGF
- s Conversion:
N/A nent Range:
0 F nent Range:
700 F ence:
N/A Notes:
N/A or:
SENSOR ors:
1 How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
N/A CONTAINMENT: B COLD LEG N/A N/A N/A N/A N/A N/A N/A 24 Date:
Reactor Unit:
Data Feeder:
NRC ERDS ParE Plant Point ID:
Plant Specific Pc Generic/Conden.
Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrun Maximum Instrur Zero Point Refer Reference Point Process or Sens Number of Sens
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 25 EPIP 5-10:31 Page 25 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
GI1 (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
RCS CHG/MU Plant Point ID:
FCHG Plant Specific Point
Description:
TOTAL CHARGING FLOW Generic/Condensed
Description:
PRIMARY SYSTEM CHARGING FLOW Analog/Digital:
ANALOG Engineering Units or Digital States:
GPM Engineering Units Conversion:
N/A Minimum Instrument Range:
0 GPM Maximum Instrument Range:
105 GPM Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
PROCESS Number of Sensors:
3 How Processed:
SUM Sensor Locations:
AUXILIARY BUILDING Alarm/Trip Setpoints:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
Total charging flow is the sum of charging flow and the A
& B reactor coolant pump seal injection flow.
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 26 EPIP 5-10:32 Page 26 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
Gil (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
FSIA Plant Specific Point
Description:
SAFETY INJECTION LOOP A AVG FLOW Generic/Condensed
Description:
HIGH PRESSURE SAFETY INJECTION F Analog/Digital:
ANALOG Engineering Units or Digital States:
GPM Engineering Units Conversion:
N/A Minimum Instrument Range:
0 GPM Maximum Instrument Range:
1000 GPM Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
PROCESS Number of Sensors:
2 How Processed:
AVERAGE Sensor Locations:
CONTAINMENT BASEMENT Alarm/Trip Setpoints:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
There are 3 safety injection pumps. Each is rated at 300 GPM at 1121 PSIG. Each pump is sized at 50% of the capacity required to meet the design criteria.
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 27 EPIP 5-10:33 Page 27 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
GI1 (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
FSIB Plant Specific Point
Description:
SAFETY INJECTION LOOP B FLOW Generic/Condensed
Description:
HIGH PRESSURE SAFETY INJECTION F Analog/Digital:
ANALOG Engineering Units or Digital States:
GPM Engineering Units Conversion:
N/A Minimum Instrument Range:
0 GPM Maximum Instrument Range:
1000 GPM Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
PROCESS Number of Sensors:
2 How Processed:
AVERAGE Sensor Locations:
CONTAINMENT BASEMENT Alarm/Trip Setpoints:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
There are 3 safety injection pumps. Each is rated at 300 GPM at 1121 PSIG. Each pump is sized at 50% of the capacity required to meet the design criteria.
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 28 EPIP 5-10:34 page 28 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
Gi1 (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
F0626 Plant Specific Point
Description:
RESIDUAL HEAT REMOVAL LOOP FLOW Generic/Condensed
Description:
LOW PRESSURE SAFETY INJECTION FL Analog/Digital:
ANALOG Engineering Units or Digital States:
GPM Engineering Units Conversion:
N/A Minimum Instrument Range:
0 GPM Maximum Instrument Range:
4E+3 GPM Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
SENSOR Number of Sensors:
1 How Processed:
N/A Sensor Locations:
AUXILIARY BUILDING Alarm/Trip Setpoints:
400 GPM, below 350 F NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
Each of two RHR pumps are rated at 1560 GPM at 120 PSI.
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:35 Page 29 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gi1 (Ginna)
N/A meter:
Description:
CONTAINMENT SUMP A AVERAGE LEVEL sed
Description:
CONTAINMENT SUMP NARROW RANGE L ANALOG s or Digital States:
FEET s Conversion:
N/A nent Range:
0 feet nent Range:
3.0E+1 feet ence:
4 inches above sump floor Notes:
N/A or:
PROCESS Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Tum-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
2 AVERAGE CONTAINMENT SUMP A BOTTOM 2.75 feet N/A N/A N/A N/A N/A N/A 29 Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Condens Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrurr Maximum Instrur Zero Point Refer' Reference Point Process or Sens
Date:
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:36 Page 30 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gi1 (Ginna)
N/A Lmeter:
Description:
SUMP B LEVEL 8 INCHES (TRAIN A) sed
Description:
CONTAINMENT SUMP WIDE RANGE LEVEL DIGITAL s or Digital States:
LOWER/HIGHER s Conversion:
N/A nent Range:
N/A nent Range:
N/A ence:
N/A Notes:
N/A or:
SENSOR ors:
1 How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
N/A CONTAINMENT SUMP B N/A N/A N/A N/A N/A N/A 8 INCHES = 70,331 GALLONS 30 Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Conden Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrun Maximum Instrun Zero Point Refer Reference Point Process or Sens Number of Sense
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
Date:
Reactor Unit:
Data Feeder:
NRC ERDS Pare Plant Point ID:
Plant Specific Pc Generic/Conden Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrun Maximum Instrur Zero Point Refer Reference Point Process or Sens Number of Sens How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
N/A CONTAINMENT SUMP B N/A N/A N/A N/A N/A N/A 78 INCHES = 75,562 GALLONS 31 EPIP 5-10:37 Page 31 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gil (Ginna)
N/A meter:
Description:
SUMP B LEVEL 78 INCHES (TRAIN A) sed
Description:
CONTAINMENT SUMP WIDE RANGE LEVEL DIGITAL
- s or Digital States:
LOWER/HIGHER
- s Conversion:
N/A nent Range:
N/A ment Range:
N/A fence:
N/A Notes:
N/A or:
SENSOR ors:
1
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Condens Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrumr Maximum Instrur Zero Point Refer Reference Point Process or Sens Number of Sens How Processed:
Sensor Location.
Alarm/Trip Setpo NI Detector Pow NI Detector Pow Instrument Failur Temperature Co Level Reference Unique System I er Supply Cut-Off Power Level:
er Supply Turn-On Power Level:
re Mode:
mpensation for DP Transmitters:
Leg:
==
Description:==
N/A N/A N/A N/A N/A 113 INCHES = 98,253 GALLONS 32 EPIP 5-10:38 Page 32 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 GIl (Ginna)
N/A meter:
Description:
SUMP B LEVEL 113 INCHES (TRAIN A) sed
Description:
CONTAINMENT SUMP WIDE RANGE LEVEL DIGITAL s or Digital States:
LOWER/HIGHER s Conversion:
N/A nent Range:
N/A nent Range:
N/A ence:
N/A Notes:
N/A or:
SENSOR ors:
1 N/A s:
CONTAINMENT BASEMENT ints:
N/A
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20) 21).
- 22)
- 23)
- 24) 25)
Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Pc Generic/Conden*
Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrun Maximum Instrur Zero Point Refer Reference Point Process or Sens Number of Sens(
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
N/A CONTAINMENT BASEMENT N/A N/A N/A N/A N/A N/A 180 INCHES = 370,161 GALLONS 33 EPIP 5-10:39 Page 33 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 GI1 (Ginna)
N/A meter:
Description:
SUMP B LEVEL 180 INCHES (TRAIN A) sed
Description:
CONTAINMENT SUMP WIDE RANGE LEVEL DIGITAL s or Digital States:
LOWER/HIGHER s Conversion:
N/A nent Range:
N/A nent Range:
N/A ence:
N/A Notes:
N/A or:
SENSOR ors:
1
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 34 EPIP 5-10:40 Page 34 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
GIl (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
L0942A Plant Specific Point
Description:
SUMP B LEVEL 214 INCHES (TRAIN A)
Generic/Condensed
Description:
CONTAINMENT SUMP WIDE RANGE LEVEL Analog/Digital:
DIGITAL Engineering Units or Digital States:
LOWER/HIGHER Engineering Units Conversion:
N/A Minimum Instrument Range:
N/A Maximum Instrument Range:
N/A Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
SENSOR Number of Sensors:
1 How Processed:
N/A Sensor Locations:
CONTAINMENT BASEMENT Alarm/Trip Setpoints:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
214 INCHES = 500,000 GALLONS
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 35 EPIP 5-10:41 Page 35 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
GI1 (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
L0943E Plant Specific Point
Description:
SUMP B LEVEL 8 INCHES (TRAIN B)
Generic/Condensed
Description:
CONTAINMENT SUMP WIDE RANGE LEVEL Analog/Digital:
DIGITAL Engineering Units or Digital States:
LOWER/HIGHER Engineering Units Conversion:
N/A Minimum Instrument Range:
N/A Maximum Instrument Range:
N/A Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
SENSOR Number of Sensors:
1 How Processed:
N/A Sensor Locations:
CONTAINMENT SUMP B Alarm/Trip Setpoints:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
8 INCHES = 70,331 GALLONS
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 36 EPIP 5-10:42 Page 36 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
GI1 (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
L0943D Plant Specific Point
Description:
SUMP B LEVEL 78 INCHES (TRAIN B)
Generic/Condensed
Description:
CONTAINMENT SUMP WIDE RANGE LEVEL Analog/Digital:
DIGITAL Engineering Units or Digital States:
LOWER/HIGHER Engineering Units Conversion:
N/A Minimum Instrument Range:
N/A Maximum Instrument Range:
N/A Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
SENSOR Number of Sensors:
1 How Processed:
N/A Sensor Locations:
CONTAINMENT SUMP B Alarm/Trip Setpoints:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
78 INCHES = 75,562 GALLONS
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 37 EPIP 5-10:43 Page 37 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
GIl (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
L0943C Plant Specific Point
Description:
SUMP B LEVEL 113 INCHES (TRAIN B)
Generic/Condensed
Description:
CONTAINMENT SUMP WIDE RANGE LEVEL Analog/Digital:
DIGITAL Engineering Units or Digital States:
LOWER/HIGHER Engineering Units Conversion:
N/A Minimum Instrument Range:
N/A Maximum Instrument Range:
N/A Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
SENSOR Number of Sensors:
1 How Processed:
N/A Sensor Locations:
CONTAINMENT BASEMENT Alarm/Trip Setpoints:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
113 INCHES = 98,253 GALLONS
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 38 EPIP 5-10:44 Page 38 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
GI1 (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
L0943B Plant Specific Point
Description:
SUMP B LEVEL 180 INCHES (TRAIN B)
Generic/Condensed
Description:
CONTAINMENT SUMP WIDE RANGE LEVEL Analog/Digital:
DIGITAL Engineering Units or Digital States:
LOWER/HIGHER Engineering Units Conversion:
N/A Minimum Instrument Range:
N/A Maximum Instrument Range:
N/A Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
SENSOR Number of Sensors:
1 How Processed:
N/A Sensor Locations:
CONTAINMENT BASEMENT Alarm/Trip Setpoints:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
180 INCHES = 370,161 GALLONS
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 39 EPIP 5-10:45 Page 39 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
GI1 (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
L0943A Plant Specific Point
Description:
SUMP B LEVEL 214 INCHES (TRAIN B)
Generic/Condensed
Description:
CONTAINMENT SUMP WIDE RANGE LEVEL Analog/Digital:
DIGITAL Engineering Units or Digital States:
LOWER/HIGHER Engineering Units Conversion:
N/A Minimum Instrument Range:
N/A Maximum Instrument Range:
N/A Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
SENSOR Number of Sensors:
1 How Processed:
N/A Sensor Locations:
CONTAINMENT BASEMENT Alarm/Trip Setpoints:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
214 INCHES = 500,000 GALLONS
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:46 Page 40 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gil (Ginna)
N/A meter:
EFF LIQ RAD R18 int
Description:
LIQUID WASTE DISPOSAL MONITOR sed
Description:
RADIOACTIVITY OF RELEASED LIQUID ANALOG s or Digital States:
CPM s Conversion:
N/A ient Range:
10 CPM "nent Range:
1.OE+7 CPM ence:
N/A Notes:
N/A or:
SENSOR Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
1 N/A AUXILIARY BUILDING - WEST END, TOP FLOOR APPROXIMATELY 7.OE+4 CPM N/A N/A N/A N/A N/A RELEASE FLOWRATE is 75 GPM. POINT IS IN UNITS OF CPM. USE 1.16E-8 TO CONVERT CPM TO itCl/CC.
40 Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Pc Generic/Condens Analog/Digital:
Engineering Unit Engineering Unit, Minimum Instrum Maximum Instrur Zero Point Refen Reference Point Process or Sensi
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific P Generic/Conden Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrur Maximum Instrur Zero Point Refer Reference Point Process or Sens Mhmnh~r nf *n How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
N/A CONTAINMENT OPERATING FLOOR 50 MR/HR N/A N/A N/A N/A N/A ABOVE 1 E+7 MR/HR USE MONITOR R29 41 EPIP 5-10:47 Page 41 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gi1 (Ginna)
N/A ameter:
CNTMNT RAD R02 oint
Description:
AREA 2-CONTAINMENT sed
Description:
RADIATION LEVEL IN CONTAINMENT ANALOG ts or Digital States:
MR/HR ts Conversion:
N/A nent Range:
-1 MR/HR ment Range:
1.OE+7 MR/HR rence:
N/A Notes:
N/A sor:
SENSOR o rS:
1
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:48 Page 42 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 GI1 (Ginna)
N/A meter:
CNMNT RAD R29 int
Description:
AREA 29-CONTAINMENT HIGH RANGE sed
Description:
RADIATION LEVEL IN CONTAINMENT ANALOG s or Digital States:
R/HR s Conversion:
N/A ent Range:
-1 MR/HR nent Range:
1.OE+7 MR/HR ence:
N/A Notes:
N/A or:
SENSOR Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
1 N/A CONTAINMENT OPERATING LEVEL 100 R/HR N/A N/A N/A N/A N/A FOR DOSE RATES BELOW 1 R/HR USE R-2 MONITOR READING 42 Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Condens Analog/Digital:
Engineering Units Engineering Units Minimum Instrum Maximum Instrum Zero Point Refere Reference Point I Process or Sensc
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
I Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
1 N/A INTERMEDIATE BLDG NORTH-CONTAINMENT VENT 9 E-3 JCI/CC N/A N/A N/A N/A N/A ABOVE 1E-5 JACI/CC USE R12A7. POINT IS IN UNITS OF JCl/CC. POINT IS ONLY A RELEASE PATH DURING CV PURGES (OUTAGES). FLOWRATE FROM RELEASE POINT IS 4.9E+6 CC/SEC.
43 Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Condens Analog/Digital:
Engineering Unite Engineering Units Minimum Instrum Maximum Instrun Zero Point Refere Reference Point I Process or Sens EPIP 5-10:49 Page 43 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 GI1 (Ginna)
N/A meter:
EFF GAS RAD R 12A5 int
Description:
CV VENT CHAN 5-LOW RANGE GAS sed
Description:
RADIOACTIVITY OF RELEASED GASSES ANALOG s or Digital States:
jiCI/CC s Conversion:
N/A ent Range:
-1.0 jtCI/CC nent Range:
1.OE+7 iaCI/CC ence:
N/A Notes:
N/A or:
SENSOR
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:50 Page 44 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gi1 (Ginna)
N/A imeter:
EFF GAS RAD R12A7 oint
Description:
CV VENT CHAN 7-MID RANGE GAS sed
Description:
RADIOACTIVITY OF RELEASED GASSES ANALOG s or Digital States:
I, CI/CC s Conversion:
N/A nent Range:
-1.0 iC I/CC nent Range:
1.OE+7 iCI/CC ence:
N/A Notes:
N/A or:
SENSOR Number of Sensors:
How Processed:
Sensor Locations:
AlarmfTrip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
1 N/A INTERMEDIATE BLDG NORTH - CONTAINMENT VENT 9E-1 RCl/CC N/A N/A N/A N/A N/A POINT IS IN UNITS OF ItCi/CC. POINT IS ONLY A RELEASE PATH DURING CV PURGES (OUTAGES).
FLOWRATE FROM RELEASE POINT IS 4.9E+6 CC/SEC. BELOW 1E-5 i.Cl/CC USE R12A5. ABOVE 1E+1 RCI/CC USE R12A9.
44 Date:
Reactor Unit:
Data Feeder:
NRC ERDS Pare Plant Point ID:
Plant Specific Pc Generic/Conden Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrun Maximum Instrur Zero Point Refer Reference Point Process or Sens
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:51 Page 45 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 GI1 (Ginna)
N/A meter:
EFF GAS RAD R12A9 int
Description:
CV VENT CHAN 9-HIGH RANGE GAS sed
Description:
RADIOACTIVITY OF RELEASED GASSES ANALOG s or Digital States:
I1.CI/CC s Conversion:
N/A ent Range:
-1.0 g+/-CI/CC nent Range:
1.OE+7 gICI/CC ence:
N/A Notes:
N/A or:
SENSOR Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
1 N/A INTERMEDIATE BLDG NORTH-CONTAINMENT VENT 90 J*CI/CC N/A N/A N/A N/A N/A BELOW 1E-3 ItCl/CC USE R12A7. POINT IS IN UNITS OF I.CI/CC. POINT IS ONLY A RELEASE PATH DURING CV PURGES (OUTAGES). FLOWRATE FROM POINT IS 4.9E+6 CC/SEC.
45 Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Condens Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrum Maximum Instrun Zero Point Refen Reference Point Process or Sens
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:52 Page 46 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gil (Ginna)
N/A meter:
EFF GAS RAD R 14A5 int
Description:
PLANT VENT CHAN 5-LOW RANGE GAS sed
Description:
RADIOACTIVITY OF RELEASED GASSES ANALOG s or Digital States:
jaCI/CC s Conversion:
N/A nent Range:
-1.0 lCI/CC nent Range:
1.OE+7 pCI/CC ence:
N/A Notes:
N/A or:
SENSOR Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
1 N/A INTERMEDIATE BLDG NORTH - PLANT VENT 1.7E-3 pCl/CC N/A N/A N/A N/A N/A ABOVE 1E-5 pCI/CC USE R14A7. POINT IS IN UNITS OF IpCI/CC. FLOWRATE FROM RELEASE PATH IS 3.6E+7 CC/SEC.
46 Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Condens Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrum Maximum Instrur Zero Point Refer Reference Point Process or Sensc
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:53 Page 47 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE-DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gil (Ginna)
N/A imeter:
EFF GAS RAD R1 4A7 iint
Description:
PLANT VENT CHAN 7-MID RANGE GAS sed
Description:
RADIOACTIVITY OF RELEASED GASSES ANALOG s or Digital States:
[,CI/CC s Conversion:
N/A nent Range:
-1.0 i, CI/CC ment Range:
1.OE+7 iiCI/CC rence:
N/A Notes:
N/A or:
SENSOR Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
1 N/A INTERMEDIATE BLDG NORTH - PLANT VENT 1.7E-1 NCA/CC N/A N/A N/A N/A N/A POINT IS IN UNITS OF 1.CI/CC. FLOWRATE FROM RELEASE POINT IS 3.6E+7 CC/SEC. BELOW 1 E-5 j.Cl/CC USE R14A5. ABOVE 1E+1 [iCI/CC USE R14A9.
47 Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Conden*
Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrun Maximum Instrun Zero Point Refer, Reference Point PrnoA~q or Sens
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
I Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
1 N/A INTERMEDIATE BLDG NORTH-PLANT VENT 1.7E+1,CI/CC N/A N/A N/A N/A N/A POINT IS IN UNITS OF RCI/CC. BELOW 1E-3 ItCI/CC USE R14A7. FLOWRATE FROM RELEASE POINT IS 3.6E+7 CC/SEC.
48 Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Conden.
Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrurr Maximum Instrur Zero Point Refer' Reference Point Process or Sens EPIP 5-10:54 Page 48 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gil (Ginna)
N/A meter:
EFF GAS RAD R 14A9 int
Description:
PLANT VENT CHAN 9-HIGH RANGE GAS sed
Description:
RADIOACTIVITY OF RELEASED GASSES ANALOG s or Digital States:
I.CI/CC s Conversion:
N/A nent Range:
-1.0 jiCI/CC nent Range:
1.OE+7 l, CI/CC ence:
N/A Notes:
N/A or:
SENSOR
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:55 Page 49 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gil (Ginna)
N/A Lmeter:
RCS LTDN RAD R09 int
Description:
AREA 9-LETDOWN LINE MONITOR sed
Description:
RAD LEVEL OF THE RCS LETDOWN LINE ANALOG s or Digital States:
MR/HR s Conversion:
N/A nent Range:
0 MR/HR nent Range:
1.OE+7 MR/HR ence:
N/A Notes:
N/A or:
SENSOR Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
1 N/A AUXILIARY BLDG BSMT IN NAOH TANK ROOM ALARM-200 MR/HR.
N/A N/A N/A N/A N/A N/A 49 Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Condenm Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrurr Maximum Instrur Zero Point Refer Reference Point Process or Sense
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:56 Page 50 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 GIl (Ginna)
N/A meter:
COND NE RAD R15A5 int
Description:
AIR EJECTOR CHAN 5-LOW RANGE GAS sed
Description:
CONDENSER AIR EJECTOR RADIOACTIV ANALOG s or Digital States:
jxCI/CC s Conversion:
N/A ent Range:
-1.0 lCI/CC "nent Range:
1.0E+7 RCI/CC ence:
N/A Notes:
N/A or:
SENSOR Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Tum-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
1 N/A TURBINE BLDG TOP LEVEL 3E-5 iCl/CC N/A N/A N/A N/A N/A POINT IS IN UNITS OF jiCI/CC. ABOVE 1E-5 gCl/CC USE R15A7. FLOWRATE FROM POINT IS 2.8E+5 CC/SEC.
50 Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Conden Analog/Digital:
Engineering Unit.
Engineering Unit.
Minimum Instrum Maximum Instrur Zero Point Refern Reference Point Process or Sense
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:57 Page 51 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gi1 (Ginna)
N/A tmeter:
COND NE RAD R 15A7 lint
Description:
AIR EJECTOR CHAN 7-MID RANGE GAS sed
Description:
CONDENSER AIR EJECTOR RADIOACTIV ANALOG s or Digital States:
gCI/CC s Conversion:
N/A nent Range:
-1.0 IgCI/CC nent Range:
1.0E+7 itCI/CC ence:
N/A Notes:
N/A or:
SENSOR Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
N/A TURBINE BLDG TOP LEVEL 5E-2 ICI/CC N/A N/A N/A N/A N/A POINT IS IN UNITS OF I.C/CC. FLOWRATE FROM POINT IS 2.8E+5 CC/SEC. BELOW 1 E-5 pCI/CC USE R15A5. ABOVE 1E+1 [,Cl/CC USE R15A9.
51 Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Conden.
Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrun Maximum Instrur Zero Point Refer Reference Point Proness or Sens
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:58 Page 52 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gi1 (Ginna)
N/A meter:
COND NE RAD R1 5A9 int
Description:
AIR EJECTOR CHAN 9-HI RANGE GAS sed
Description:
CONDENSER AIR EJECTOR RADIOACTIV ANALOG s or Digital States:
PCI/CC s Conversion:
N/A ent Range:
-1.0,CI/CC nent Range:
1.0E+7,CI/CC ence:
N/A Notes:
N/A or:
SENSOR Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
1 N/A TURBINE BLDG TOP FLOOR 5 igCI/CC N/A N/A N/A N/A N/A POINT IS IN UNITS OF g.CI/CC. FLOWRATE FROM POINT IS 2.8E+5 CC/SEC. BELOW 1 E-3 g.CI/CC USE R15A7.
52 Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Condens Analog/Digital:
Engineering Unit, Engineering Unit Minimum Instrum Maximum Instrur Zero Point Refen Reference Point Process or Sense
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:59 Page 53 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 GI1 (Ginna)
N/A meter:
MAIN SL 1/A R31 int
Description:
AREA 31 STEAM LINE A (SPING) sed
Description:
STM GEN 1 (OR A) STEAM LINE RAD ANALOG s or Digital States:
MR/HR s Conversion:
N/A ent Range:
-1.0 MR/HR nent Range:
1.OE+7 MR/HR ence:
N/A Notes:
N/A or:
SENSOR Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
1 N/A INTERMEDIATE BLDG NORTH 0.1 MR/HR N/A N/A N/A N/A N/A N/A 53 Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Condens Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrum Maximum Instrun Zero Point Refer Reference Point Process or Sensc
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:60 Page 54 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 GI1 (Ginna)
N/A meter:
MAIN S/L 2/B R32 int
Description:
AREA 32 STEAM LINE B (SPING) sed
Description:
STM GEN 2 (OR B) STEAM LINE RAD ANALOG s or Digital States:
MR/HR s Conversion:
N/A nent Range:
-1.0 MR/HR nent Range:
1.0E+7 MR/HR ence:
N/A Notes:
N/A or:
SENSOR Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
1 N/A INTERMEDIATE BLDG NORTH 0.1 MR/HR N/A N/A N/A N/A N/A N/A 54 Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Condens Analog/Digital:
Engineering Unit Engineering Unit:
Minimum Instrum Maximum Instrur Zero Point Refer Reference Point Process or Sens.
Date:
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:61 Page 55 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97
.Gil (Ginna)
N/A ameter:
SG BD RAD R19
)int
Description:
STEAM GENERATOR BLOWDOWN DRAIN sed
Description:
STM GEN BLOWDOWN RAD LEVEL ANALOG s or Digital States:
CPM s Conversion:
N/A nent Range:
1.OE+1 CPM nent Range:
1.OE+7 CPM ence:
N/A Notes:
N/A or:
SENSOR Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
1 N/A INTERMEDIATE BLDG SOUTH ABOVE NUCLEAR SAMPLE ROOM ALARM AND ISOLATE = 6000 CPM N/A N/A N/A N/A N/A POINT IS IN UNITS OFCPM. "A" AND "B" S/G BLOWDOWNS ARE COMBINED.
55 Reactor Unit:
Data Feeder:
NRC ERDS Pare Plant Point ID:
Plant Specific Pc Generic/Conden Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrun Maximum Instrun Zero Point Refer Reference Point Process or Sens
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 56 EPIP 5-10:62 Page 56 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
Gil (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
CTMNT PRESS Plant Point ID:
PCV Plant Specific Point
Description:
CONTAINMENT AVERAGE PRESSURE Generic/Condensed
Description:
CONTAINMENT PRESSURE Analog/Digital:
ANALOG Engineering Units or Digital States:
PSIG Engineering Units Conversion:
N/A Minimum Instrument Range:
-2.5 PSIG Maximum Instrument Range:
60 PSIG Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
PROCESS Number of Sensors:
3 How Processed:
AVG Sensor Locations:
INTERMEDIATE AND AUX BLDGS Alarm/Trip Setpoints:
4E+0 PSIG NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
PT945, PT947, PT949 INPUTS BEING USED.
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 57 EPIP 5-10:63 Page 57 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
Gil (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
CTMNT TEMP Plant Point ID:
TCV03 Plant Specific Point
Description:
CV BASEMENT LEVEL 6FT TEMP #3 Generic/Condensed
Description:
CONTAINMENT TEMPERATURE Analog/Digital:
ANALOG Engineering Units or Digital States:
DEFG Engineering Units Conversion:
N/A Minimum Instrument Range:
0 Maximum Instrument Range:
300 Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
SENSOR Number of Sensors:
1 How Processed:
N/A Sensor Locations:
CONTAINMENT BASEMENT Alarm/Trip Setpoints:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
N/A
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Conden*
Analog/Digital:
Engineering Unit Engineering Unit Minimum Instrun Maximum Instrur Zero Point Refer Reference Point Process or Sens Number of Sense How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
N/A CONTAINMENT INTERMEDIATE LEVEL N/A N/A N/A N/A N/A N/A N/A 58 EPIP 5-10:64 Page 58 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gil (Ginna)
N/A meter:
CTMNT TEMP TCV07 int
Description:
CV INTERMEDIATE LVL 6FT TEMP #7 sed
Description:
CONTAINMENT TEMPERATURE ANALOG s or Digital States:
DEGF s Conversion:
N/A nent Range:
0 nent Range:
300 ence:
N/A Notes:
N/A or:
SENSOR ors:
1
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 59 EPIP 5-10:65 Page 59 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
Gil (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
CTMNT TEMP Plant Point ID:
TCV17 Plant Specific Point
Description:
CV OPERATING LEVEL 6FT TEMP #17 Generic/Condensed
Description:
CONTAINMENT TEMPERATURE Analog/Digital:
ANALOG Engineering Units or Digital States:
DEGF Engineering Units Conversion:
N/A Minimum Instrument Range:
0 Maximum Instrument Range:
300 Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
SENSOR Number of Sensors:
1 How Processed:
N/A Sensor Locations:
CONTAINMENT OPERATING LEVEL Alarm/Trip Setpoints:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
N/A
EPIP 5-10:66 Page 60 of 66
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
TRIC CORPORATION ATA SYSTEM (ERDS)
- ARY (DPL) 9/5/97 GIl (Ginna)
N/A H2 CONC ROCHESTER GAS & ELECi EMERGENCY RESPONSE D DATA POINT LIBF Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Plant Point ID:
Plant Specific Point
Description:
Generic/Condensed
Description:
Analog/Digital:
Engineering Units or Digital States:
Engineering Units Conversion:
Minimum Instrument Range:
Maximum Instrument Range:
Zero Point
Reference:
Reference Point Notes:
Process or Sensor:
Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
60 CVH CV HYDROGEN CONCENTRATION CONTAINMENT H2 CONCENTRATION ANALOG N/A 0%
1.OE+1%
N/A N/A PROCESS 2
AVG INTERMEDIATE BLDG BSMT NORTH 4E+0%
N/A N/A N/A N/A N/A N/A
ROCHESTER GAS & ELE(
EMERGENCY RESPONSE DATA POINT LIB Date:
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:65 Page 61 of 67
- TRIC CORPORATION DATA SYSTEM (ERDS)
IRARY (DPL) 9/5/97 Gil (Ginna)
N/A BWST LEVEL LRWST REFUELING WATER STORAGE TANK LVL BORATED WATER STORAGE TANK LEVEL ANALOG Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Plant Point ID:
Plant Specific Point
Description:
Generic/Condensed
Description:
Analog/Digital:
Engineering Units or Digital States:
Engineering Units Conversion:
Minimum Instrument Range:
Maximum Instrument Range:
Zero Point
Reference:
Reference Point Notes:
Process or Sensor:
Number of Sensors:
How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
61 1% = 3380 GALLONS 0%
100%
N/A N/A PROCESS 2
AVG AUX BLDG HIGH = 95, LOW = 10 N/A N/A N/A N/A N/A N/A
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 62 EPIP 5-10:68 Page 62 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
GIl (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
WIND SPEED Plant Point ID:
WS033 Plant Specific Point
Description:
33 FOOT LEVEL WIND SPEED Generic/Condensed
Description:
WIND SPEED AT REACTOR SITE Analog/Digital:
ANALOG Engineering Units or Digital States:
MPH Engineering Units Conversion:
N/A Minimum Instrument Range:
0 MPH Maximum Instrument Range:
50 MPH Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
SENSOR Number of Sensors:
1 How Processed:
N/A Sensor Locations:
MET TOWER NORTHWEST OF PLANT Alarm/Trip Setpoints:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
N/A
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Conden Analog/Digital:
Engineering Unit.
Engineering Unit Minimum Instrurm Maximum Instrur Zero Point Refer' Reference Point Process or Sens Number of Sens How Processed:
Sensor Location*
Alarm/Trip Setpo NI Detector Pow' NI Detector Pow' Instrument Failur Temperature Coi Level Reference Unique System 63 EPIP 5-10:69 Page 63 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 GIl (Ginna)
N/A meter:
WIND DIR WD033 pint
Description:
33 FOOT LEVEL WIND DIRECTION sed
Description:
WIND DIRECTION AT THE REACTOR SITE ANALOG s or Digital States:
DEG s Conversion:
N/A nent Range:
-1.0E+1 nent Range:
5.5E+2 ence:
N/A Notes:
N/A or:
SENSOR ors:
1 N/A s:
MET TOWER NORTHWEST OF PLANT ints:
N/A er Supply Cut-Off Power Level:
N/A er Supply Turn-On Power Level:
N/A re Mode:
N/A mpensation for DP Transmitters:
N/A Leg:
N/A
==
Description:==
WIND DIRECTION IS THE DIRECTION THAT THE WIND IS COMING FROM.
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
EPIP 5-10:70 Page 64 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gil (Ginna)
N/A ameter:
STAB CLASS WT033 oint
Description:
33 FOOT LEVEL TEMPERATURE sed
Description:
AIR STABILITY AT REACTOR SITE ANALOG ts or Digital States:
DEGF ts Conversion:
N/A "nent Range:
-20 F ment Range:
120 F rence:
N/A Notes:
N/A sor:
SENSOR ors:
1 How Processed:
Sensor Locations:
Alarm/Trip Setpoints:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-On Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System
Description:
N/A MET TOWER NORTHWEST OF PLANT N/A N/A N/A N/A N/A N/A N/A 64 Date:
Reactor Unit:
Data Feeder:
NRC ERDS ParE Plant Point ID:
Plant Specific Po Generic/Conden Analog/Digital:
Engineering Unil Engineering Unit Minimum Instrur Maximum Instrur Zero Point Refei Reference Point Process or Sens Number of Sens
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25) 65 EPIP 5-10:71 Page 65 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL)
Date:
9/5/97 Reactor Unit:
Gil (Ginna)
Data Feeder:
N/A NRC ERDS Parameter:
STAB CLASS Plant Point ID:
WT250 Plant Specific Point
Description:
250 FOOT LEVEL TEMPERATURE Generic/Condensed
Description:
AIR STABILITY AT REACTOR SITE Analog/Digital:
ANALOG Engineering Units or Digital States:
DEGF Engineering Units Conversion:
N/A Minimum Instrument Range:
-20 F Maximum Instrument Range:
120 F Zero Point
Reference:
N/A Reference Point Notes:
N/A Process or Sensor:
SENSOR Number of Sensors:
1 How Processed:
N/A Sensor Locations:
MET TOWER NORTHWEST OF PLANT Alarm/Trip Setpoints:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-On Power Level:
N/A Instrument Failure Mode:
N/A Temperature Compensation for DP Transmitters:
N/A Level Reference Leg:
N/A Unique System
Description:
N/A
- 1)
- 2)
- 3)
- 4)
- 5)
- 6)
- 7)
- 8)
- 9)
- 10)
- 11)
- 12)
- 13)
- 14)
- 15)
- 16)
- 17)
- 18)
- 19)
- 20)
- 21)
- 22)
- 23)
- 24) 25)
Date:
Reactor Unit:
Data Feeder:
NRC ERDS Para Plant Point ID:
Plant Specific Po Generic/Condens Analog/Digital:
Engineering Units Engineering Unit Minimum Instrum Maximum Instrum Zero Point Refere Reference Point I Process or Sensc Number of Senso How Processed:
Sensor Locations AlarmlTrip Setpoi NI Detector Powe NI Detector Powe Instrument Failure Temperature Con Level Reference I Unique System D A= <-2.17. B=>2.17F & <-1.95F. C= >-1.95F & <-1.74F.
D= >-1.74F & <-0.65F. E= >-0.65F & <+1.74F.
F= >+1.74F & <+4.77F. G= >+4.77F 66 EPIP 5-10:72 Page 66 of 66 ROCHESTER GAS & ELECTRIC CORPORATION EMERGENCY RESPONSE DATA SYSTEM (ERDS)
DATA POINT LIBRARY (DPL) 9/5/97 Gi1 (Ginna)
N/A meter:
STAB CLASS WDT2 int
Description:
250 TO 33 FOOT LEVEL DELTA TEMP sed
Description:
AIR STABILITY AT REACTOR SITE ANALOG s or Digital States:
DEGF s Conversion:
N/A ent Range:
-10 F nent Range:
1OF nce:
N/A Notes:
N/A
)r:
PROCESS irs:
2 D/F MET TOWER NORTHWEST OF PLANT nts:
N/A r Supply Cut-Off Power Level:
N/A
- r Supply Turn-On Power Level:
N/A e Mode:
N/A ipensation for DP Transmitters:
N/A Leg:
N/A escription:
REPORT NO.
01 REPORT: NPSP0200 DOC TYPE: PREPIP PARAMETERS:
DOC PROCEDURE NUMBER EPIP-1-0 EPIP-1-1 EPIP-1-2 EPIP-1-3 EPIP-1-4 EPIP-1-5 EPIP-1-6 EPIP-1-7 EPIP-1-8 EPIP-1-9 EPIP-1-10 EPIP-1-11 EPIP-1-12 EPIP-1-13 EPIP-1-15 EPIP-1-16 EPIP-1-17 EPIP-1-18 EPIP-2-1 EPIP-2-2 EPIP-2-3 EPIP-2-4 EPIP-2-5
-.TD_
TYPES PREPIP GINNA NUCLEAR POWER PLANT PROCEDURES INDEX EMERGENCY PLAN IMPLEMENTING PROCEDURE STATUS:
EF 03/28/02 PAGE:
1 5
PROCEDURE TITLE GINNA STATION EVENT EVALUATION AND CLASSIFICATION UNUSUAL EVENT ALERT SITE AREA EMERGENCY GENERAL EMERGENCY NOTIFICATIONS SITE EVACUATION ACCOUNTABILITY OF PERSONNEL SEARCH AND RESCUE OPERATION TECHNICAL SUPPORT CENTER ACTIVATION OPERATIONAL SUPPORT CENTER (OSC) ACTIVATION SURVEY CENTER ACTIVATION REPAIR AND CORRECTIVE ACTION GUIDELINES DURING EMERGENCY SITUATIONS LOCAL RADIATION EMERGENCY USE OF THE HEALTH PHYSICS NETWORK HPN RADIOACTIVE LIQUID RELEASE TO LAKE ONTARIO OR DEER CREEK PLANNING FOR ADVERSE WEATHER DISCRETIONARY ACTIONS FOR EMERGENCY CONDITIONS PROTECTIVE ACTION RECOMMENDATIONS OBTAINING METEOROLOGICAL DATA AND FORECASTS AND THEIR USE IN EMERGENCY DOSE ASSESSMENT EMERGENCY RELEASE RATE DETERMINATION EMERGENCY DOSE PROJECTIONS -
MANUAL METHOD EMERGENCY DOSE PROJECTIONS PERSONAL COMPUTER METHOD rMvpnvm'Y DOSE PROJECTIONS MIDAS PROGRAM YEARS ONLY:
EFFECT REV DATE 027 08/22/01 003 11/02/01 004 11/02/01 005 12/09/96 005 11/02/01 048 03/01/02 013 12/20/01 009 11/02/01 005 12/20/01 021 12/20/01 010 07/25/00 025 02/06/02 009 12/20/01 003 08/04/95 005 04/24/96 004 02/13/98 002 06/21/00 001 02/06/02 019 06/04/01 011 09/28/01 014 013 013 011 09/28/01 07/20/01 08/31/01 06/21/00 LAST REVIEW 08/22/01 11/02/01 11/02/01 01/23/98 11/02/01 03/01/02 121/20/01 11/02/01 12/20/01 12/20/01 07/25/00 02/06/02 12/20/01 01/23/98 03/03/99 02/13/98 06/21/00 02/06/02 06/04/01 09/28/01 09/28/01 07/20/01 08/31/01 06/21/00 NEXT REVIEW 08/22/06 11/02/06 11/02/06 01/20/03 11/02/06 03/01/07 12/20/06 11/02/06 12/20/06 12/20/06 07/25/05 02/06/07 12/20/06 01/23/03 03/03/04 02/13/03 06/21/05 02/06/07 06/04/06 09/28/06 09/28/06 07/20/06 08/31/06 06/21/05 ST EF EF EF EF EF EF EF EF EF EF EF EF EF EF EF EF EF EF EF EF EF EF EF
REPORT NO.
01 REPORT: NPSP0200 DOC TYPE: PREPIP PARAMETERS: DOC TYPES PROCEDURE NUMBER EPIP-2-7 EPIP-2-8 EPIP-2-9 EPIP-2-10 EPIP-2-11 EPIP-2-12 EPIP-2-13 EPIP-2-14 EPIP-2-15 EPIP-2-16 EPIP-2-17 EPIP-2-18 EPIP-3-1 EPIP-3-2 EPIP-3-3 EPIP-3-4 EPIP-3-7 EPIP-4-1 EPIP-4-3 EPIP-4-6 EPIP-4-7 EPIP-5-1 EPIP-5-2 PREPIP PROCEDURE MANAGEMEN VOLUNTARY ADMINISTR INPLANT R ONSITE SU GINNA NUCLEAR POWER PLANT PROCEDURES INDEX EMERGENCY PLAN IMPLEMENTING PROCEDURE STATUS: EF TITLE TOF EMERGENCY SURVEY TEAMS ACCEPTANCE OF EMERGENCY RADIATION EXPOSURE ATION OF POTASSIUM IODIDE (KI)
ADIATION SURVEYS 7RVEYS 03/28/02 PAGE:
2 5 YEARS ONLY; EFFECT REV DATE 010 10/23/00 005 05/16/00 004 02/06/02 003 01/16/97 018 02/06/02 OFFSITE SURVEYS 021 IODINE AND PARTICULATE ACTIVITY DETERMINATION FROM AIR SAMPLES 008 POST PLUME ENVIRONMENTAL SAMPLING 014 POST PLUME EVALUATION OF OFFSITE DOSES DUE TO DEPOSITION 005 CORE DAMAGE ESTIMATION 011 HYPOTHETICAL (PRE-RELEASE)
DOSE ESTIMATES 007 CONTROL ROOM DOSE ASSESSMENT 013 EMERGENCY OPERATIONS FACILITY (EOF)
ACTIVATION AND OPERATIONS 017 ENGINEERING SUPPORT CENTER (ESC) 009 IMMEDIATE ENTRY 008 EMERGENCY TERMINATION AND RECOVERY 008 SECURITY DURING EMERGENCIES 009 PUBLIC INFORMATION RESPONSE TO AN UNUSUAL EVENT 006 ACCIDENTAL ACTIVATION OF GINNA EMERGENCY NOTIFICATION SYSTEM SIRENS 009 JOINT EMERGENCY NEWS CENTER ACTIVATION 009 PUBLIC INFORMATION ORGANIZATION STAFFING 019 OFFSITE EMERGENCY RESPONSE FACILITIES AND EQUIPMENT PERIODIC INVENTORY 023 CHECKS AND TESTS ONSITE EMERGENCY RESPONSE FACILITIES AND EQUIPMENT PERIODIC INVENTORY 026 CHECKS AND TESTS 02/06/02 07/27/99 12/04/00 02/06/02 08/31/01 03/01/02 09/28/01 08/31/01 03/12/01 12/20/01 03/12/01 11/16/99 02/13/98 03/01/02 08/31/01 03/01/02 02/06/02 LAST REVIEW 10/23/00 05/16/00 02/06/02 01/16/97 02/06/02 02/06/02 07/27/99 12/04/00 02/06/02 08/31/01 03/01/02 09/28/01 08/31/01 03/12/01 12/20/01 03/12/01 11/16/99 02/13/98 03/01/02 08/31/01 03/01/02 02/06/02 NEXT REVIEW 10/23/05 05/16/05 02/06/07 01/16/02 02/06/07 02/06/07 07/27/04 12/04/05 02/06/07 08/31/06 03/01/07 09/28/06 08/31/06 03/12/06 12/20/06 03/12/06 11/16/04 02/13/03 03/01/07 08/31/06 03/01/07 02/06/07 ST EF EF EF EF EF EF EF EF EF EF EF EF EF EF EF EF EF EF EF EF EF EF 11/02/01 11/02/01 11/02/06 EF
REPORT NO.
01 REPORT: NPSP0200 DOC TYPE: PREPIP PARAMETERS: DOC TYPES PROCEDURE NUMBER EPIP-5-5 EPIP-5-6 EPIP-5-7 EPIP-5-9 EPIP-5-10 NERP TOTAL FOR PREPIP GINNA NUCLEAR POWER PLANT PROCEDURES INDEX EMERGENCY PLAN IMPLEMENTING PROCEDURE STATUS: EF PREPIP 5 YEARS ONLY:
PROCEDURE TITLE REV CONDUCT OF DRILLS AND EXERCISES 013 ANNUAL REVIEW OF NUCLEAR EMERGENCY RESPONSE PLAN (NERP) 004 EMERGENCY ORGANIZATION 034 TESTING THE OFF HOURS CALL-IN PROCEDURE AND QUARTERLY TELEPHONE NUMBER 006 CHECK EMERGENCY RESPONSE DATA SYSTEM (ERDS) 006 GINNA STATION NUCLEAR EMERGENCY RESPONSE PLAN 010 03/28/02 PAGE:
3 EFFECT DATE 08/31/01 05/28/99 12/20/01 05/28/99 LAST REVIEW 08/31/01 o5/28/99 12/20/01 05/28/99 NEXT REVIEW ST 08/31/06 EF 05/28/04 EF 12/20/06 EF 05/28/04 EF 03/28/02 03/28/02 03/28/07 EF 03/21/01 03/21/01 12/09/04 EF 53