ML020450031

From kanterella
Jump to navigation Jump to search
Technical Specification Page for Correction of Typographical Error in Amendment 178
ML020450031
Person / Time
Site: Cooper Entergy icon.png
Issue date: 02/12/2002
From:
NRC/NRR/DLPM
To:
References
Download: ML020450031 (1)


Text

Primary Containment Isolation Instrumentation 3.3.6.1 Table 3.3.6.1-1 (page 3 of 3)

Primary Containment Isolation Instrumentation APPLICABLE CONDITIONS MODES OR REQUIRED REFERENCED OTHER CHANNELS FROM SPECIFIED PER TRIP REQUIRED SURVEILLANCE ALLOWABLE FUNCTION CONDITIONS SYSTEM ACTION C.1 REQUIREMENTS VALUE S.

RHR Shutdown Cooling System Isolation

a.

Reactor 1,2,3 1

F SR 3.3.6.1.2

<72 psig Pressure - High SR 3.3.6.1.4 SR 3.3.6.1.6

b.

Reactor Vessel Water 3,4,5 4 (b)

I SR 3.3.6.1.1

> 3 inches Level - Low (Level 3)

SR 3.3.6.1.2 SR 3.3.6.1.4 SR 3.3.6.1.6 (b)

Only one trip system is required in MODES 4 and 5 when RHR Shutdown Cooling System integrity maintained.

Amendment 178 Cooper 3.3-53