DPR-66 Table Index (cont.)
TABLE 3.3-11 4.3-7 3.3-13 4.3-13 4.4-1 4.4-2 4.4-3 4.4-12 3.7-1 j.7-2 4.7-2 3.8-1 3.9-1 Accident Monitoring Instrumentation Accident Monitoring Instrumentation Surveillance Requirements Explosive Gas Monitoring Instrumentation Explosive Gas Monitoring Instrumentation Surveillance Requirements Minimum Number of Steam Generators to be Inspected During Inservice Inspection Steam Generator Tube Inspection Reactor Coolant System Pressure Isolation Valves Primary Coolant Specific Activity Sample and Analysis Program OPERABLE Main Steam Safety Valves versus Maximum Allowable Power Steam Line Safety Valves Per Loop Secondary Coolant System Specific Activity Sample and Analysis Program Battery Surveillance Requirements Beaver Valley Fuel Assembly Minimum Burnup vs.
Initial U235 Enrichment For Storage in Region 2 Spent Fuel Racks BEAVER VALLEY -
UNIT 1 TITLE PAGE 3/4 3-51 3/4 3-52 3/4 3-55 3/4 3-57 3/4 4-10g 3/4 4-10h 3/4 4-14b 3/4 4-20 3/4 7-2 3/4 7-4 3/4 7-9 3/4 8-9a 3/4 9-15 Amendment No. 248 XVI I
DPR-66 3/4.7 PLANT SYSTEMS 3/4.7.1 TURBINE CYCLE MAIN STEAM SAFETY VALVES (MSSVs)
LIMITING CONDITION FOR OPERATION 3.7.1.1 Five MSSVs per steam generator shall be OPERABLE.
APPLICABILITY:
MODES 1, 2 and 3.
ACTION:
GENERAL NOTE Separate ACTION entry is allowed for each MSSV.
- a.
With one or more steam generators with one MSSV inoperable and the Moderator Temperature Coefficient (MTC) zero or negative at all power levels, within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> reduce THERMAL POWER to less than or equal to 61% RTP; otherwise, be in HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, and in HOT SHUTDOWN within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.
- b.
With one or more steam generators with two or more MSSVs inoperable, or with one or more steam generators with one
_.MSSV inoperable and the MTC positive at any power level, within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> reduce THERMAL POWER to less than or equal to the Maximum Allowable % RTP specified in Table 3.7-1 for the number of OPERABLE MSSVs, and reduce the Power Range Neutron Flux-High reactor trip setpoint to less than or equal to the Maximum Allowable
% RTP specified in Table 3.7-1 for the number of OPERABLE MSSVs within the next 32 hours3.703704e-4 days <br />0.00889 hours <br />5.291005e-5 weeks <br />1.2176e-5 months <br />'-';
otherwise, be in HOT STANDBY within the next 6
hours, and in HOT SHUTDOWN within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.
- c.
With one or more steam generators with four or more MSSVs inoperable, within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> be in HOT STANDBY and in HOT SHUTDOWN within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.
- d.
The provisions of Specification 3.0.4 are not applicable.
SURVEILLANCE REQUIREMENTS 4.7.1.1 Verify12 each required MSSV lift setpoint per Table 3.7-2 in accordance with the Inservice Testing Program.
Following
- testing, lift settings shall be within + 1 percent.
(1) Required to be performed only in MODE 1.
(2)
Required to be performed only in MODES 1 and 2.
BEAVER VALLEY -
UNIT 1 3/4 7-1 Amendment No.
248
DPR-66 TABLE 3.7-1 OPERABLE Main Steam Safety Valves versus Maximum Allowable Power NUMBER OF OPERABLE MSSVs MAXIMUM ALLOWABLE POWER PER STEAM GENERATOR
(% RTP) 4
< 58 3
< 41 2
< 24 BEAVER VALLEY -
UNIT 1 3/4 7-2 (next page is 3/4 7-4)
Amendment No. 248
NPF-73 3/4.7 PLANT SYSTEMS 3/4.7.1 TURBINE CYCLE MAIN STEAM SAFETY VALVES (MSSVs)
LIMITING CONDITION FOR OPERATION 3.7.1.1 Five MSSVs per steam generator shall be OPERABLE.
APPLICABILITY:
MODES 1, 2 and 3.
ACTION:
GENERAL NOTE Separate ACTION entry is allowed for each MSSV.
- a.
With one or more steam generators with one MSSV inoperable and the Moderator Temperature Coefficient (MTC) zero or negative at all power levels, within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> reduce THERMAL POWER to less than or equal to 61% RTP; otherwise, be in HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, and in HOT SHUTDOWN within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.
- b.
With one or more steam generators with two or more MSSVs inoperable, or with one or more steam generators with one
.MSSV inoperable and the MTC positive at any power level, within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> reduce THERMAL POWER to less than or equal to the Maximum Allowable % RTP specified in Table 3.7-1 for the number of OPERABLE MSSVs, and reduce the Power Range Neutron Flux-High reactor trip setpoint to less than or equal to the Maximum Allowable
% RTP specified in Table 3.7-1 for the number of OPERABLE MSSVs within the next 32 hours3.703704e-4 days <br />0.00889 hours <br />5.291005e-5 weeks <br />1.2176e-5 months <br />' -;
otherwise, be in HOT STANDBY within the next 6
hours, and in HOT SHUTDOWN within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.
- c.
With one or more steam generators with four or more MSSVs inoperable, within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> be in HOT STANDBY and in HOT SHUTDOWN within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.
- d.
The provisions of Specification 3.0.4 are not applicable.
SURVEILLANCE REQUIREMENTS 4.7.1.1 Verify1 2 each required MSSV lift setpoint per Table 3.7-2 in accordance with the Inservice Testing Program.
Following testing, lift settings shall be within + 1 percent.
(1) Required to be performed only in MODE 1.
(2)
Required to be performed only in MODES 1 and 2.
BEAVER VALLEY -
UNIT 2 Amendment No.
127 3/4 7-1
NPF-73 TABLE 3.7-1 OPERABLE Main Steam Safety Valves versus Maximum Allowable Power NUMBER OF OPERABLE MSSVs MAXIMUM ALLOWABLE POWER PER STEAM GENERATOR
(% RTP) 4
< 58 3
< 41 2
< 24 BEAVER VALLEY -
UNIT 2 Amendment No. 127 3/4 7-2