ML020240321

From kanterella
Jump to navigation Jump to search

Tech Spec Page, Amendment No. 173, Unit 3
ML020240321
Person / Time
Site: San Onofre 
(NPF-015)
Issue date: 01/24/2002
From:
NRC/NRR/DLPM
To:
References
Download: ML020240321 (1)


Text

Procedures, Programs, and Manuals 5.5 5.5 Procedures, Programs, and Manuals (continued) 5.5.2.14 Configuration Risk Management Program (CRMP)

(Continued)

d.

Provisions for assessing the need for additional actions after the discovery of additional equipment out of service conditions while in the LCO Condition.

e.

Provisions for considering other applicable risk significant contributors such as Level 2 issues, and external events, qualitatively or quantitatively.

5.5.2.15 Containment Leakage Rate Testing Program A program shall be established to implement the leakage rate testing of the containmen as required by 10 CFR 50.54(o) and 10 CFR 50, Appendix J, Option B, as modified by approved exemptions.

This program shall be in accordance with the guidelines contained in Regulatory Guidr 1.163, "Performance-Based Containment Leak-Test Program", dated September 1995.

The calculated peak containment internal pressure related to the design basis loss-of-coolant accident, Pa, is 45.9 psig (Pa will conservatively be assumed to be equal to the calculated peak containment internal pressure for the design basis Main Steam Line Break (56.5 psig) for the purpose of containment testing in accordance with this Technical Specification).

The maximum allowable containment leakage rate, La, at Pa, shall be 0.10% of containment air weight per day.

Leakage rate acceptance criteria are:

a.

The Containment overall leakage rate acceptance criterion is

  • 1.0 La.

During the first unit startup following testing in accordance with this program, the leakage rate acceptance criteria are : 0.60 La for the Type B and Type C tests and

! 0.75 La for the Type A tests;

b.

Air lock testing acceptance criteria are:

1)

Overall air lock leakage rate is : 0.05 L, when tested at Ž Pa.

2)

For each door, the leakage rate is

  • 0.01 La when pressurized to z 9.0 psig.

Amendment No.

173 SAN ONOFRE--UNIT 3 5.0-20a