Text

- 4a -

G.

The following programs shall be implemented and maintained by the licensee:

(1) A secondary water chemistry monitoring program to inhibit steam generator tube degradation. This program shall include: the identification of critical parameters, their sampling frequency, sampling points and control band limits; requirements for the documentation and review of sample results; the identification of the authority responsible for the interpretation of sample results; the procedures used to measure the critical parameters; and the procedures which identify the administrative events and corrective actions required to return the secondary chemistry to its normal control band following an out of control band condition.

(2) A program to reduce leakage from systems outside containment that would or could contain highly radioactive fluids during a serious transient or accident to as low as practical levels. This program shall include:

provisions for preventive maintenance and periodic visual inspection requirements, and integrated leak test requirements for each system at a frequency not to exceed refueling cycle intervals.

(3) A program to determine the airborne iodine concentration in vital areas under accident conditions. This program shall include: training of personnel, procedures for monitoring, and provisions for maintenance of sampling and analysis equipment.

(4) DELETED Amendment No. 192 HBRSEP, Unit No. 2

5.5 Programs and Manuals 5.5.1 Offsite Dose Calculation Manu jalLQD2OMJ (continued) markings n tce margin of '-e affected pages, ciear7y inaJcating the area of the page that was changed, ann shall indicate the date (i.e., month and year) ie cnange A 's implemented 5.5.2 Primarv Coolant Sources Outside Containment This program provides controls to reduce leakage from those portions of systems outside containment that could contain highly radioactive fluids during a serious transient or accident to levels as low as practicable. The systems include Residual Heat Removal, Safety Injection, Containment Spray, Post Accident Containment Ventilation; and portions of Chemical and Volume Control, Liquid Waste Disposal, Gaseous Waste Disposal, and Sampling. The program shall include the following:

a.

Preventive maintenance and periodic visual inspection requirements; and

b.

Integrated leak test requirements for each system at refueling cycle intervals or less.

DFLE.TFD Radioactive Effluent Controls Program 5.5.3 5.5.4 This program conforms to 10 CFR 50.36a for the control of radioactive effluents and for maintaining :he doses to members of (continued)

Amendment No. T76, 192 HBRSEP Unit No. 2 5.0-8