Procedures,

Programs, and Manuals 5.7 5.7 Procedures, Programs, and Manuals Offsite Dose Calculation Manual (ODCM)

(continued)

c.

Shall be submitted to the NRC in the form of a complete, legible copy of the entire ODCM as a part of or concurrent with the Radioactive Effluent Release Report for the period of the report in which any change in the ODCM was made.

Each change shall be identified by markings in the margin of the affected pages, clearly indicating the area of the page that was changed, and shall indicate the date (i.e.,

month and year) the change was implemented.

Primary Coolant Sources Outside Containment This program provides controls to minimize leakage from those portions of systems outside containment that could contain highly radioactive fluids during a serious transient or accident to levels as low as practicable.

The systems include Containment Spray, Safety Injection, Residual Heat Removal, Chemical and Volume Control, Reactor Coolant System Sampling, and Waste Gas.

The program shall include the following:

a.

Preventive maintenance and periodic visual requirements; and

b.

Integrated leak test requirements for each refueling cycle intervals or less.

inspection system at (removed from Technical Specifications)

(removed from Technical Specifications)

(continued)

Watts Bar-Unit 1 5.0-11 5.7.2.3 5.7.2.4 5.7.2.5 5.7.2.6 Amendnmt No. 34 I

PAM Instrumentation B 3.3.3 BASES ACTIONS D.1 (continued)

Condition D applies when two hydrogen monitor channels are inoperable.

Required Action D.1 requires restoring one hydrogen monitor channel to 'PERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.

The 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Completion Time is reasonable based on the low probability that a LOCA (which would cause core damage) would occur during this time.

E.1 Condition E applies when the Required Action and associated Completion Time of Condition C or D are not met.

Required Action E.1 requires entering the appropriate Condition referenced in Table 3.3.3-1 for the channel immediately.

The applicable Condition referenced in the Table is Function dependent.

Each time an inoperable channel has not met any Required Action of Condition C or D, and the associated Completion Time has expired, Condition E is entered for that channel and provides for transfer to the appropriate subsequent Condition.

F.1 and F.2 If the Required Action and associated Completion Time of Conditions C or D are not met and Table 3.3.3-1 directs entry into Condition F, the plant must be brought to a MODE where the requirements of this LCO do not apply.

To achieve this status, the plant must be brought to at least MODE 3 within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and MODE 4 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

The allowed Completion Times are reasonable, based on operating experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.

(continued)

Watts Bar-Unit 1 B 3.3-137 Azmmndmmet No.

3M