January 17, 2002 Mr. John T. Conway Site Vice President Nine Mile Point Nuclear Station, LLC P.O. Box 63 Lycoming, NY 13093
SUBJECT:
NINE MILE POINT NUCLEAR STATION, UNIT NO. 2 - REQUEST FOR ADDITIONAL INFORMATION - AMENDMENT APPLICATION RE: MINIMUM CRITICAL POWER RATIO (TAC MB3327)
Dear Mr. Conway:
The U.S. Nuclear Regulatory Commission (NRC) staff is reviewing the subject proposed amendment, requested by your letter dated November 20, 2001. On January 16, 2002, we held a telephone discussion with Messrs. S. Leonard and D. Vandeputte, et al. of your staff, as well as General Electric personnel, on comments we previously e-mailed (publicly available in ADAMS Accession No. ML020150318). The NRC staff decided that a written response is needed from you to address those two issues. The enclosed Request for Additional Information (RAI) formalizes the NRC staffs information request.
Please respond expeditiously to support your proposed amendment issuance date of February 21, 2002.
Sincerely,
/RA/
Peter S. Tam, Senior Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-410
Enclosure:
RAI cc w/encl: See next page
ML020150318). The NRC staff decided that a written response is needed from you to address those two issues. The enclosed Request for Additional Information (RAI) formalizes the NRC staffs information request.
Please respond expeditiously to support your proposed amendment issuance date of February 21, 2002.
Sincerely,
/RA/
Peter S. Tam, Senior Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-410
Enclosure:
RAI cc w/encl: See next page DISTRIBUTION:
PDI-1 R/F PUBLIC JMunday PTam OGC THuang ACRS RCaruso BPlatchek SLittle Accession Number: ML020160483
- see previous concurrence OFFICE PDI-1/PM PDI-1/LA SRXB SRXB/SC PDI-1/SC(A)
NAME PTam**
SLittle THuang*
RCaruso*
JMunday**
DATE 1/17/02 1/17/02 1/16/02 1/17/02 1/17/02
REQUEST FOR ADDITIONAL INFORMATION NINE MILE POINT NUCLEAR STATION, UNIT NO. 2 AMENDMENT APPLICATION DATED NOVEMBER 20, 2001 SAFETY LIMITS MINIMUM CRITICAL POWER RATIO 1.
Provide information on the reference core loading pattern for Cycle 8 and Cycle 9, including bundle name, number in core, and identification of cycle loaded.
2.
Describe the difference between the reference core loading pattern for the amendment calculation and the real core loading pattern. Also, describe the procedure to deal with the difference if it occurs.
Enclosure
Nine Mile Point Nuclear Station Unit No. 2 cc:
Regional Administrator, Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Resident Inspector Nine Mile Point Nuclear Station P.O. Box 126 Lycoming, NY 13093 Mr. John V. Vinquist, MATS Inc.
P.O. Box 63 Lycoming, NY 13093 Supervisor Town of Scriba Route 8, Box 382 Oswego, NY 13126 Mr. Paul D. Eddy Electric Division NYS Department of Public Service Agency Building 3 Empire State Plaza Albany, NY 12223 Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271 C. Adrienne Rhodes Chairman and Executive Director State Consumer Protection Board 5 Empire State Plaza, Suite 2101 Albany, NY 12223-1556 Mark J. Wetterhahn, Esquire Winston & Strawn 1400 L Street, NW.
Washington, DC 20005-3502 Mr. Robert E. Denton President Nine Mile Point Nuclear Station, LLC 1997 Annapolis Exchange Parkway Suite 500 Annapolis, MD 21401 Mr. Raymond L. Wenderlich Senior Constellation Nuclear Officer Responsible for Nine Mile Point Nine Mile Point Nuclear Station, LLC P.O. Box 63 Lycoming, NY 13093 James M. Petro, Jr., Esquire Counsel Constellation Power Source, Inc.