MONTHYEARML11236A1342011-07-31031 July 2011 Westinghouse WCAP-17400-NP, Rev. 0, Prairie Island, Units 1 and 2 Spent Fuel Pool Criticality Safety Analysis, Enclosure 4 Project stage: Request L-2011-409, Revision to Extended Power Uprate License Amendment Request Proposed Technical Specification Regarding Fuel Loading Curve and Areal Density Criteria for Metamic Inserts2011-10-14014 October 2011 Revision to Extended Power Uprate License Amendment Request Proposed Technical Specification Regarding Fuel Loading Curve and Areal Density Criteria for Metamic Inserts Project stage: Request ML1125602172011-10-25025 October 2011 Request for Withholding of Proprietary Information from Public Disclosure Project stage: Withholding Request Acceptance ML1206203892012-03-20020 March 2012 Request for Additional Information Related to License Amendment Request for Spent Fuel Pool Criticality Changes Project stage: RAI L-2012-132, Extended Power Uprate License Amendment Request - Supplement to Proposed Technical Specification Changes Related to Spent Fuel Storage Requirements and Core Operating Limits Report (COLR) References2012-03-31031 March 2012 Extended Power Uprate License Amendment Request - Supplement to Proposed Technical Specification Changes Related to Spent Fuel Storage Requirements and Core Operating Limits Report (COLR) References Project stage: Supplement L-PI-12-038, Westinghouse, Affidavit - CE-12-3 16, Revision 1, Westingliouse Suggested Responses to the Requests for Additional Information Presented in ML120620389.2012-05-0303 May 2012 Westinghouse, Affidavit - CE-12-3 16, Revision 1, Westingliouse Suggested Responses to the Requests for Additional Information Presented in ML120620389. Project stage: Other ML12139A1982012-05-16016 May 2012 Response to Requests for Additional Information (RAI) Associated with Spent Fuel Pool Criticality Changes (TAC Nos. ME6984 and ME69851) Project stage: Response to RAI ML12215A2522012-08-0707 August 2012 Request for Additional Information Related to License Amendment Request for Spent Fuel Pool Criticality Changes Project stage: RAI L-PI-12-066, Enclosure 2 to L-PI-12-066 - Westinghouse Affidavit, Application for Withholding Proprietary Information from Public Disclosure2012-08-27027 August 2012 Enclosure 2 to L-PI-12-066 - Westinghouse Affidavit, Application for Withholding Proprietary Information from Public Disclosure Project stage: Request ML12249A0692012-09-0404 September 2012 Response to Requests for Additional Information (RAI) Associated with Spent Fuel Pool Criticality Changes Project stage: Response to RAI ML13011A3162013-01-22022 January 2013 Request for Additional Information Related to License Amendment Request for Spent Fuel Pool Criticality Changes Project stage: RAI L-PI-13-002, Response to Request for Additional Information (RAI) Associated with Spent Fuel Pool Criticality Changes2013-02-0808 February 2013 Response to Request for Additional Information (RAI) Associated with Spent Fuel Pool Criticality Changes Project stage: Response to RAI ML13197A3972013-06-25025 June 2013 NRR E-mail Capture - Prairie Island Ngp - Sfpc LAR Draft RAI Project stage: Draft Other L-PI-13-067, Response to Request for Additional Information (RAI) Associated with Spent Fuel Pool Criticality Changes2013-07-17017 July 2013 Response to Request for Additional Information (RAI) Associated with Spent Fuel Pool Criticality Changes Project stage: Response to RAI ML13241A3832013-08-29029 August 2013 Issuance of Amendments Spent Fuel Pool Criticality Changes Project stage: Approval 2012-08-27
[Table View] |
|
---|
Category:Letter type:L
MONTHYEARL-PI-23-034, Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 3.7.8, Cooling Water (Cl) System,2024-01-0202 January 2024 Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 3.7.8, Cooling Water (Cl) System, L-PI-23-035, Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specifications Section 5.6.6, Reactor Coolant System (RCS) Pressure and Temperature Limits Report2023-12-20020 December 2023 Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specifications Section 5.6.6, Reactor Coolant System (RCS) Pressure and Temperature Limits Report L-PI-23-033, Supplement to License Amendment Request to Revise Technical Specification 3.8.1, Surveillance Requirement 3.8.1.2, Note 32023-12-0505 December 2023 Supplement to License Amendment Request to Revise Technical Specification 3.8.1, Surveillance Requirement 3.8.1.2, Note 3 L-PI-23-025, License Amendment Request to Revise Technical Specification 3.8.1, Surveillance Requirement 3.8.1.2, Note 32023-09-28028 September 2023 License Amendment Request to Revise Technical Specification 3.8.1, Surveillance Requirement 3.8.1.2, Note 3 L-PI-23-023, Baffle Former Bolts Alternate Aging Management Strategy2023-09-11011 September 2023 Baffle Former Bolts Alternate Aging Management Strategy L-PI-23-018, License Amendment Request to Revise ISFSI Technical Specification 4.4 to Allow Use of a Code Alternative to ASME Code, NB-5130, Examination of Weld Edge Preparation Surfaces, for the TN-40HT2023-07-14014 July 2023 License Amendment Request to Revise ISFSI Technical Specification 4.4 to Allow Use of a Code Alternative to ASME Code, NB-5130, Examination of Weld Edge Preparation Surfaces, for the TN-40HT L-PI-23-006, License Amendment Request to Revise Technical Specification 3.7.8 Required Actions2023-06-22022 June 2023 License Amendment Request to Revise Technical Specification 3.7.8 Required Actions L-PI-23-016, 2022 10 CFR 50.46 LOCA Annual Report2023-06-14014 June 2023 2022 10 CFR 50.46 LOCA Annual Report L-PI-23-010, Annual Report of Individual Monitoring2023-04-27027 April 2023 Annual Report of Individual Monitoring L-PI-23-007, Supplement to Application to Revise Technical Specification Section 5.6.6, Reactor Coolant System (RCS) Pressure and Temperature Limits Report (PTLR)2023-03-28028 March 2023 Supplement to Application to Revise Technical Specification Section 5.6.6, Reactor Coolant System (RCS) Pressure and Temperature Limits Report (PTLR) L-PI-23-005, CFR 50.55a Requests Nos. 1-RR-5-15 and 2-RR-5-15, Proposed Use of Subsequent ASME Code Edition and Addenda in Accordance with 10 CFR 50.55a(g)(4)(iv)2023-03-0303 March 2023 CFR 50.55a Requests Nos. 1-RR-5-15 and 2-RR-5-15, Proposed Use of Subsequent ASME Code Edition and Addenda in Accordance with 10 CFR 50.55a(g)(4)(iv) L-PI-23-001, Day Steam Generator Tube Inspection Report2023-01-30030 January 2023 Day Steam Generator Tube Inspection Report L-PI-22-047, Resubmittal of Prairie Island Nuclear Generating Plant (PINGP) 2018 Unit 1 180-Day Steam Generator Tube Inspection Report2022-12-21021 December 2022 Resubmittal of Prairie Island Nuclear Generating Plant (PINGP) 2018 Unit 1 180-Day Steam Generator Tube Inspection Report L-PI-22-020, Application to Revise Technical Specification Section 5.6.6, Reactor Coolant System (RCS) Pressure and Temperature Limits Report (PTLR)2022-12-0202 December 2022 Application to Revise Technical Specification Section 5.6.6, Reactor Coolant System (RCS) Pressure and Temperature Limits Report (PTLR) L-PI-22-040, Supplement to Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections2022-10-0606 October 2022 Supplement to Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections L-PI-22-037, Updated Approach for Prairie Island Unit 1 and Unit 2 Baffle Former Bolts2022-09-20020 September 2022 Updated Approach for Prairie Island Unit 1 and Unit 2 Baffle Former Bolts L-PI-22-032, CFR 50.46 LOCA Annual Report2022-06-16016 June 2022 CFR 50.46 LOCA Annual Report L-PI-22-033, Response to Request for Additional Information Prairie Island Nuclear Generating Plant, Units 1 and 2, Amendment to Adopt 24-Month Operating Cycles2022-06-10010 June 2022 Response to Request for Additional Information Prairie Island Nuclear Generating Plant, Units 1 and 2, Amendment to Adopt 24-Month Operating Cycles L-PI-22-003, Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections2022-06-0707 June 2022 Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections L-PI-22-024, Supplement to Application for License Amendment to Implement 24-Month Operating Cycle2022-03-0707 March 2022 Supplement to Application for License Amendment to Implement 24-Month Operating Cycle L-PI-21-047, Response to Request for Additional Information 24-Month Cycle Amendment Prairie Island Nuclear Generating Plant, Units 1 and 22021-12-0707 December 2021 Response to Request for Additional Information 24-Month Cycle Amendment Prairie Island Nuclear Generating Plant, Units 1 and 2 L-PI-21-045, Response to Request for Additional Information Cooling Water System License Amendment Request2021-11-0404 November 2021 Response to Request for Additional Information Cooling Water System License Amendment Request L-PI-21-029, Exigent License Amendment Request to Revise Technical Specification 3.7.8 to Allow a One-Time Extension of the Completion Time of Required Action B.12021-10-0707 October 2021 Exigent License Amendment Request to Revise Technical Specification 3.7.8 to Allow a One-Time Extension of the Completion Time of Required Action B.1 L-PI-21-006, License Amendment Request to Revise Technical Specification 3.3.1, Reactor Trip System (RTS) Instrumentation, to Incorporate Installed Bypass Test Capability for the Power Range RTS Functions2021-10-0202 October 2021 License Amendment Request to Revise Technical Specification 3.3.1, Reactor Trip System (RTS) Instrumentation, to Incorporate Installed Bypass Test Capability for the Power Range RTS Functions L-PI-21-032, Response to Request for Additional Information Amendment Request to Adopt TSTF-471 and 571-T for Prairie Island2021-09-30030 September 2021 Response to Request for Additional Information Amendment Request to Adopt TSTF-471 and 571-T for Prairie Island L-PI-21-016, Application for License Amendment to Implement 24-Month Operating Cycle2021-08-0606 August 2021 Application for License Amendment to Implement 24-Month Operating Cycle L-PI-21-027, 2020 10 CFR 50.46 LOCA Annual Report2021-06-28028 June 2021 2020 10 CFR 50.46 LOCA Annual Report L-PI-21-023, Independent Spent Fuel Storage Installation - 2020 Annual Radiological Environmental Monitoring Program Report2021-05-14014 May 2021 Independent Spent Fuel Storage Installation - 2020 Annual Radiological Environmental Monitoring Program Report L-PI-21-007, Application to Revise Technical Specifications to Adopt TSTF-471, Eliminate Use of the Term Core Alterations in Actions and Notes2021-04-19019 April 2021 Application to Revise Technical Specifications to Adopt TSTF-471, Eliminate Use of the Term Core Alterations in Actions and Notes L-PI-20-050, Request for a One-Time Exemption from 10 CFR 50, Appendix E, Biennial Emergency Preparedness Exercise Requirements, Due to COVID-19 Pandemic2020-10-0707 October 2020 Request for a One-Time Exemption from 10 CFR 50, Appendix E, Biennial Emergency Preparedness Exercise Requirements, Due to COVID-19 Pandemic L-PI-20-051, Supplement to Application to Revise Technical Specifications to Adopt TSTF-547, Clarification of Rod Position Requirements2020-09-28028 September 2020 Supplement to Application to Revise Technical Specifications to Adopt TSTF-547, Clarification of Rod Position Requirements L-PI-20-026, Response to Request for Additional Information: License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiativ2020-09-0101 September 2020 Response to Request for Additional Information: License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4 L-PI-20-035, = Request for Revision to Reactor Vessel Material Surveillance Capsule Removal Schedule2020-07-28028 July 2020 = Request for Revision to Reactor Vessel Material Surveillance Capsule Removal Schedule L-PI-20-023, Independent Spent Fuel Storage Installation, Response to Request for Additional Information: License Amendment Request to Expand the Storage Capacity of the Independent Spent Fuel Storage Installation (ISFSI)2020-06-10010 June 2020 Independent Spent Fuel Storage Installation, Response to Request for Additional Information: License Amendment Request to Expand the Storage Capacity of the Independent Spent Fuel Storage Installation (ISFSI) L-PI-20-014, Supplement to License Amendment Request: Expand the Storage Capacity of the Independent Spent Fuel Storage Installation (ISFSI2020-04-29029 April 2020 Supplement to License Amendment Request: Expand the Storage Capacity of the Independent Spent Fuel Storage Installation (ISFSI L-PI-20-004, License Amendment Request to Revise Technical Specifications (TS) to Remove Note I from Limiting Condition for Operating (LCO) 3.4.12 and LCO 3.4.132020-03-30030 March 2020 License Amendment Request to Revise Technical Specifications (TS) to Remove Note I from Limiting Condition for Operating (LCO) 3.4.12 and LCO 3.4.13 L-PI-20-001, License Amendment Request to Address Issues Identified in Westinghouse Nuclear Safety Advisory Letter NSAL-09-5, Revision 1, and NSAL-15-12020-01-29029 January 2020 License Amendment Request to Address Issues Identified in Westinghouse Nuclear Safety Advisory Letter NSAL-09-5, Revision 1, and NSAL-15-1 L-PI-19-041, Application to Revise Technical Specifications to Adopt TSTF-547, Clarification of Rod Position Requirements2019-12-23023 December 2019 Application to Revise Technical Specifications to Adopt TSTF-547, Clarification of Rod Position Requirements L-PI-19-031, License Amendment Request: Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b2019-12-16016 December 2019 License Amendment Request: Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b L-PI-19-040, License Amendment Request: Revise Technical Specification 5.5.14 to Permanently Extend Containment Leakage Rate Test Frequency2019-10-0707 October 2019 License Amendment Request: Revise Technical Specification 5.5.14 to Permanently Extend Containment Leakage Rate Test Frequency L-PI-19-038, Submittal of Revised Pressure and Temperature Limits Report2019-09-19019 September 2019 Submittal of Revised Pressure and Temperature Limits Report L-PI-19-037, Response to Request for Additional Information: 10 CFR 50.55a Requests Nos. 1-RR-5-10 and 2-RR-5-10, Proposed Alternative to Reactor Vessel Inservice Inspection (ISI) Intervals2019-09-16016 September 2019 Response to Request for Additional Information: 10 CFR 50.55a Requests Nos. 1-RR-5-10 and 2-RR-5-10, Proposed Alternative to Reactor Vessel Inservice Inspection (ISI) Intervals L-PI-19-025, Request to Approve Site-Specific Probabilistic Risk Assessment (PRA) Model for Flowserve N-Seal Abeyance Seal and Dynamic Testing for the Prairie Island Nuclear Generating Plant (PINGP)2019-08-27027 August 2019 Request to Approve Site-Specific Probabilistic Risk Assessment (PRA) Model for Flowserve N-Seal Abeyance Seal and Dynamic Testing for the Prairie Island Nuclear Generating Plant (PINGP) L-PI-19-029, Supplement to Response to Request for Additional Information: Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components For...2019-08-0505 August 2019 Supplement to Response to Request for Additional Information: Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components For... L-PI-19-002, 10 CFR 50.55a Requests Nos. 1-RR-5-10 and 2-RR-5-10, Proposed Alternative to Reactor Vessel Inservice Inspection (ISI) Intervals for Prairie Island, Unit 1 and Unit 22019-06-13013 June 2019 10 CFR 50.55a Requests Nos. 1-RR-5-10 and 2-RR-5-10, Proposed Alternative to Reactor Vessel Inservice Inspection (ISI) Intervals for Prairie Island, Unit 1 and Unit 2 L-PI-19-014, Response to Request for Additional Information: Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors2019-04-29029 April 2019 Response to Request for Additional Information: Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors L-PI-19-003, Request for Revision to Reactor Vessel Material Surveillance Capsule Removal Schedule for Prairie Island Nuclear Generating Plant (PINGP)2019-02-0404 February 2019 Request for Revision to Reactor Vessel Material Surveillance Capsule Removal Schedule for Prairie Island Nuclear Generating Plant (PINGP) L-PI-19-006, Emergency License Amendment Request Regarding One-Time Extension for Technical Specification Completion Time Requirements2019-01-29029 January 2019 Emergency License Amendment Request Regarding One-Time Extension for Technical Specification Completion Time Requirements L-PI-19-005, Online Reference Portal for NRC Review of License Amendment Request to Implement 10 CFR 50.692019-01-15015 January 2019 Online Reference Portal for NRC Review of License Amendment Request to Implement 10 CFR 50.69 L-PI-18-063, Response to Request for Additional Information: Revise License Condition Associated with Implementation of NFPA 8052018-12-0606 December 2018 Response to Request for Additional Information: Revise License Condition Associated with Implementation of NFPA 805 2024-01-02
[Table view] |
Text
Prairie Island Nuclear Generating Plant 1717 Wakonade Drive East Welch, MN 55089 July 17, 2013 L-PI-13-067 10 CFR 50.90 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Prairie Island Nuclear Generating Plant, Units 1 and 2 Dockets 50-282 and 50-306 Renewed License Nos. DPR-42 and DPR-60 Response to Request for Additional Information (RAI) Associated with Spent Fuel Pool Criticality Changes (TAC Nos. ME6984 and ME6985)
References:
- 1. Mark A Schimmel (NSPM) letter to Document Control Desk (NRC),
License Amendment Request for Spent Fuel Pool Criticality Changes, dated August 19, 2011 (ADAMS Accession ML11236A133).
- 2. Thomas J Wengert (NRC) letter to James E Lynch (NSPM), Prairie Island Nuclear Generating Plant, Units 1 and 2 - Request for Additional Information Related to License Amendment Request for Spent Fuel Pool Criticality Changes (TAC Nos. ME6984 and ME6985), dated January 22, 2013 (ADAMS Accession No. ML13011A316).
- 3. James E Lynch (NSPM) letter to Document Control Desk (NRC),
Response to Request for Additional Information (RAI) Associated with Spent Fuel Pool Criticality Changes (TAC Nos. ME6984 and ME6985), dated February 8, 2013 (ADAMS Accession No. ML13039A306).
- 4. Thomas Wengert (NRC) email to Glenn Adams (NSPM), Prairie Island NGP - SFPC LAR Draft RAI (TAC Nos. ME6984 and ME6985), dated June 25, 2013.
In a letter to the U.S. Nuclear Regulatory Commission (NRC) dated August 19, 2011 (Reference 1), the Northern States Power Company, a Minnesota corporation doing business as Xcel Energy (hereafter NSPM), requested an amendment to the Technical Specifications (TS) regarding Spent Fuel Pool (SFP) criticality for the Prairie Island Nuclear Generating Plant (PINGP).
To complete their review, the NRC staff requested additional information in Reference
- 2. In Reference 3, NSPM replied to Reference 2 and included a revision to the
Document Control Desk Page 2 commitment regarding treatment of fuel assemblies exposed to rodded operation.
Subsequently in Reference 4, the NRC staff requested further clarification of the subject commitment. Clarification to that commitment is provided below as well as in the Enclosure.
NSPM submits this information in accordance with the provisions of 10 CFR 50.90.
The supplemental information provided in this letter does not impact the conclusions of the Determination of No Significant Hazards Consideration and Environmental Assessment presented in the August 19, 2011 submittal.
In accordance with 10 CFR 50.91, NSPM is notifying the State of Minnesota of this response to RAis by transmitting a copy of this letter to the designated State Official.
Summary of Commitments This letter revises commitment number 2 listed in Enclosure 7 of the original LAR, which was subsequently revised in the Reference 2 letter. The revised commitment reads as follows:
- 2. In conjunction with implementation of the proposed TS, procedures will be revised to require an assessment of a fuel assembly's exposure to rodded power operation in the core prior to moving that fuel assembly into the spent fuel pool (SFP) storage racks. If an assembly experiences more than 100 megawatt days per metric ton uranium (MWd/MTU) of core average full-power rodded operation exposure, this exposure experienced while rodded will not be credited for determining the coefficients used to categorize fuel assemblies as described in WCAP-17 400-P.
I declare under penalty of perjury that the foregoing is true and correct.
Executed on July 17, 2013.
da~~cf;-
Site ~ ~r~sident, Prairie Island Nuclear Generating Plant Northern States Power Company - Minnesota Enclosure cc: Regional Administrator, Region Ill, USNRC Project Manager, Prairie Island Nuclear Generating Plant, USNRC Resident Inspector, Prairie Island Nuclear Generating Plant, USNRC State of Minnesota (without enclosure)
Enclosure L-PI-13-067 Page 1 of 2 ENCLOSURE Spent Fuel Pool Criticality Analysis Response to Request for Addition Information (RAI)
By letter dated August 19, 2011 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML11236A133), as supplemented by letters dated May 16, 2012 (ML12139A198), September 4, 2012 (ML12249A069), and February 8, 2013, (ML13039A306) Northern States Power Company, a Minnesota corporation doing business as Xcel Energy (the licensee), requested changes to the Technical Specifications (TS) for Prairie Island Nuclear Generating Plant, Units 1 and 2 (PINGP).
Approval of this license amendment request (LAR) will correct non-conservatisms in the spent fuel pool (SFP) nuclear criticality safety (NCS) analysis of record and the associated TS.
To complete their review, the NRC staff requested additional information by electronic mail dated June 25, 2013 For clarity, the NRC RAI information is provided below in italics font and the NSPM response is provided in plain font.
The February 8, 2013, letter contained the following revised commitment:
In conjunction with implementation of the proposed TS, procedures will be revised to require an assessment of a fuel assembly's exposure to rodded power operation in the core prior to moving that fuel assembly into the spent fuel pool (SFP) storage racks. If an assembly experiences more than 100 megawatt days per metric ton uranium (MWd/MTU) of core average full-power rodded operation exposure in the cycle immediately prior to discharge to the spent fuel pool, this exposure experienced while rodded will not be credited for determining the coefficients used to categorize fuel assemblies as described in WCAP-17400-P.
In addition if an assembly experiences more than 1 gigawatt day per metric ton uranium (GWd/MTU) of core average rodded operation lifetime exposure, the assembly shall be either treated as Fuel Category 1 or evaluated to determine which Fuel Category is appropriate for safe storage of the assembly.
The second sentence of the commitment would require a fuel assembly that receives between 100 megawatt days per metric ton uranium (MWd/MTU) and 1 gigawatt day per metric ton uranium (GWd/MTU) of rodded operation during a cycle (aka cycle N) to have that portion of its depletion discounted when determining which fuel categories it satisfies for storage. However, that burnup would not have to be discounted for storage determinations following subsequent cycles of operation (i.e., cycles N+1 or N+2).
NUREG-6759 indicates that once a positive reactivity effect occurs due to rodded operation, it probably does not ever burnout to zero; therefore any penalty that was incurred would have to follow that fuel assembly for its entire life. Even without that, if the affected fuel assemblies had to be offloaded within a few days of the start of the
Enclosure L-PI-13-067 Page 2 of 2 N+1 cycle, the positive reactivity caused by the rodded operation would not have had time to burnout. Therefore the NRC staff requests that the licensee provide justification for not continuing the rodded operation penalty for the entire life of each affected fuel assembly.
Response: Rather than justifying the proposal to discount the rodded exposure in previous operating cycles, NSPM has elected to change the text of the commitment to eliminate the proposed practice. This is accomplished by striking the phrase in the cycle immediately prior to discharge to the spent fuel pool.
The NRC staff believes that storing any fuel assembly that has more than 1 GWd/MTU of rodded operation as a fresh fuel assembly to be conservative and acceptable.
However the phrase or evaluated to determine which Fuel Category is appropriate implies an acceptable methodology for making that evaluation. The NRC staff has been unable to discern the methodology the licensee would use to make this evaluation from the currently submitted information. Therefore, the NRC staff requests the licensee to either provide the rodded operation evaluation methodology for review or strike the phrase from the commitment.
Response: Rather than providing the rodded operation evaluation methodology, NSPM has elected to change the text of the commitment to eliminate the proposed practice. This is accomplished by striking the last sentence of the commitment. In effect, the revised commitment will delete the 1 GWd/MTU threshold entirely such that any rodded exposure greater than 100 MWd/MTU will not be credited for determining the coefficients used to categorize fuel assemblies as described in WCAP-17400-P.